630A4-26-409 Equipment Listing.xlsx
XLSX spreadsheet 89 KB Posted
- Solicitation number
- 36C24226B0035
About this file
This is an equipment listing spreadsheet documenting the mechanical systems and HVAC equipment across multiple buildings at St. Albans Community Living Center. The document provides detailed inventories of air handling units, chillers, pumps, exhaust fans, boilers, and ancillary equipment distributed across Buildings 85, 86, 87, 88, 89, 173 (Consolidated Laundry), and 64 (Boiler Plant), with specifications including manufacturer, model number, serial number, year of manufacture, capacity ratings, and operational parameters. Equipment ranges from 1948 vintage steam radiators to 2022 newly installed units, encompassing both central systems and packaged units serving various facility functions including nursing care, food services, administration, and laundry operations.
The equipment data captured includes critical operational information such as control types (BAS, local control, time clock), operating hours, motor specifications, cooling/heating capacities, refrigerant types (primarily R-410A and R-22), and available documentation status (control schematics, operations and maintenance information). Notable entries include multiple water tube boilers at the central plant (Victory DT-2-33 models rated at 30,000-50,000 lbs/hr capacity), numerous packaged air conditioning units and split-system units with Trane, Carrier, York, and McQuay manufacturers, and extensive distribution of window air conditioning units (143 total Friedrich units) across multiple floors and buildings. The spreadsheet also documents 15 fan coil units in the domiciliary rooms and multiple DHW heat exchangers and pumps supporting the facility's hot water distribution system.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36C24226B0035 0001.docx | DOCX document | |
| VA NOTICE OF LIMITATIONS ON SUBCONTRACTING CERTIFICATION.pdf | ||
| 52.225-2 Buy American Certificate.pdf | ||
| NY Tax Exempt Form.pdf | ||
| Wage Determination.pdf | ||
| 36C24226B0035_1.docx | DOCX document |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Bldg Sum
| Building Summary |
| Project Name: |
| Project #: |
| Prepared By: |
Facility # Facility Type and Use Year Built Gross Floor Area (ft²) Perimeter (ft) # of Stories # of Windows and Doors Window Type Wall Type Roof Type # of Occupants Hours of Operation Overall Condition Recent Renovations and Planned Improvements Notes
MechEquipDetails
| Mechanical Equipment List | UNITS TO BE SERVICED OR REPLACED INCLUDE BUT ARE NOT LIMITED TO THE LISTING BELOW. | ||
| Project Name: | Replace AC Package Units | Legend | |
| Project #: | 630A4-26-409 | Not Applicable | |
| Prepared By: | John Kolade | - | Information Not Available |
| PUMP DETAILS | CHILLER/CONDENSING UNIT DETAILS | COOLING TOWER | AIR HANDLING UNITS | ||||||||||||||||||||||||||||||||||||||||||||||
| GENERAL DATA | EQUIPMENT DATA | OPERATIONAL INFO | MOTOR DATA | PUMP DATA | GENERAL | ELECTRICAL | CONTROL | COOLING TOWER | FANS | ||||||||||||||||||||||||||||||||||||||||
| Facility # | Facility Name / Description | Equipment Location | Area/Equipment Served | Equip Tag | Equipment Type | Manufacturer | Model Number | Serial Number | Quantity | Year of Manufacture | Sequence of Operation Available | Control Schematic Available | O&M Info Available | Operating Hours | Control Type | Motor HP | VFD | Motor Efficiency (%) | Flow (GPM) | Head (feet) | Chiller Type | Capacity (Tons) | Refrigerant Type | Flow (GPM) | EWT (F) or EAT | LWT (F) | Clg Efficiency (kW/Ton) | Design Input kW | Min kW | CHW Temp Reset (Y/N) | OAT Enable Temp (F) | Stages of Cooling | # of Cells | Flow (GPM) | EWT (F) | LWT (F) | CW Temp Reset (Y/N) | Fan HP | Airflow (CFM) | System Type | Total Airflow (CFM) | OSA Min (CFM) | ESP (IN WC) | TSP (IN WC) | Supply Fan Motor HP | SF Motor Efficiency (%) | |||
| 85 | Intermediate Care - Wards C and D | Grounds Outside | Bldg 85 C1 Dayroom | AHU-2 | Packaged AHU | Carrier | Carrier 39MN | 1 | 2018 | 24/7 | BAS | ||||||||||||||||||||||||||||||||||||||
| 85 | Intermediate Care - Wards C and D | Grounds Outside | Bldg 85 C1 Ward | AHU-1 | Packaged AHU | Carrier | Carrier 39MN | 1 | 2018 | 24/7 | BAS | ||||||||||||||||||||||||||||||||||||||
| 86 | Intermediate Care - Wards C and D | Bldg 86 Basement Mechanical Room | Bldg 86 Floors 2,3 (abandoned) | AHU-1 | Central AHU | McQuay | MSL-222CH | 3FD00484 | 1 | 1987 | Abandoned | Abandoned | CV AHU, Steam Htg, 100% OA | - | - | - | - | 20 | 87.50% | ||||||||||||||||||||||||||||||
| 86 | Intermediate Care - Wards C and D | Outside Bldg 86 | Adult Day Health Care | ACU-3 | Packaged AHU | Trane Intellipak | SSHLF40E6D45E7BD1011ABC0FG00000RT0M8600 | C11A00414 | 1 | 2012 | 8:30 am to 4:30 pm | BAS | Pkgd VAV AHU, DX Clg, Steam Htg | 11500 | 2580 | 3.6 | 25 | Hi Eff | |||||||||||||||||||||||||||||||
| 87 | Nursing Care – Ward B | Bldg 87 Roof | 2nd & 3rd Floors, East | AHU B1 | Central AHU | McQuay | RPS060DSS | FBOU101101235 00 | 1 | 2010 | Cooling Season | BAS | Pkgd VAV AHU, DX Clg, Steam Htg | 11000 | 3000 | - | - | 10 | - | ||||||||||||||||||||||||||||||
| 87 | Nursing Care – Ward B | Bldg 87 Roof | 2nd & 3rd Floors, West | AHU B2 | Central AHU | McQuay | RPS060DSS | FBOU101101244 00 | 1 | 2010 | Cooling Season | BAS | Pkgd VAV AHU, DX Clg, Steam Htg | 11000 | 3000 | - | - | 10 | - | ||||||||||||||||||||||||||||||
| 87 | Nursing Care – Ward B | Basement Mechanical Room | Basement SPD | SPD AHU | Central AHU | XeteX | XHR-30G-48-BP-CW-HS-HM | 120900310 | 1 | 2011 | 24/7 | BAS | CV Reheat AHU, CHW Clg, Steam Htg | 4175 | 4175 | 1.5 | 5.8 | 7.5 | - | ||||||||||||||||||||||||||||||
| 87 | Nursing Care – Ward B | Ground Floor Mechanical Room | Chapel | Chapel ACU | Central AHU | York | EBV182-A | JS048198 | 1 | - | Cooling Season | Local Control | Pkgd CV AHU, DX Clg Only | - | - | - | - | 3 | - | ||||||||||||||||||||||||||||||
| 87 | Nursing Care – Ward B | Outside - Ground Level | Basement SPD AHU | SPD Chiller | Chiller | York | YCALOO28EE17XEA SDTX AXXRLXXXX 44XX1XXXX XXXSXXX XXX 1XXXXXN BXAXED | SFWM631060 | 1 | 2011 | 24/7 | BAS | Air Cooled | 20.9 | R-410A | 50.0 | 55.0 | 44.0 | 1.43 | 29.9 | - | N | - | ||||||||||||||||||||||||||
| 88 | Food Commissary-Dietetics / Domiciliary S | 2nd Floor Mechanical Room | Auditorium | AHU-2 | |||||||||||||||||||||||||||||||||||||||||||||
| (Auditorium AHU) | Central AHU | SnyderGeneral | LSL150DH | 3XD01050-04 | 1 | 1992 | Cooling Season | BAS | VAV AHU, CHW Clg, Steam Htg | - | - | - | - | 20 | - | - | 5 | 89.9% | Y | - | - | ||||||||||||||||||||||||||||
| 88 | Food Commissary-Dietetics / Domiciliary S | 2nd Floor Small Mech Room near Domicilliary | Commissary Kitchen - Basement | AHU-2 | Central AHU | York | AP400FSAFII30 | CER-013(…unreadable) | 1 | 1985 | 24/7 | BAS | CV AHU, CHW Clg, Steam Htg | 18700 | 18700 | - | - | 20 | 93.6% | ||||||||||||||||||||||||||||||
| 87 | Nursing Care – Ward B | Outside - Ground Level | Chapel AHU | Chapel ACCU | Condensing Unit | Carrier | 38AKS016---500-- | 1595F42797 | 1 | - | Cooling Season | Local Control | Air Cooled | 15 | R-22 | 1.25 | 18.8 | - | |||||||||||||||||||||||||||||||
| 88 | Food Commissary-Dietetics / Domiciliary S | 2nd Floor Small Mech Room near Domicilliary | Diet Kitchen | HV-1 | Central AHU | - | no plate visible | 1 | 1980's | 6am to 6pm, 7 days/wk | BAS | CV AHU, Steam Htg, 100% OA | 9000 | 9000 | - | - | 7.5 | - | |||||||||||||||||||||||||||||||
| 88 | Food Commissary-Dietetics / Domiciliary S | 2nd Floor Mechanical Room | Commissary Offices Basement | AHU-1 | |||||||||||||||||||||||||||||||||||||||||||||
| (Commissary Offices AHU) | Central AHU | SnyderGeneral McQuay | LSL164DH | 3XD01049-04 | 1 | 1992 | 6am to 7pm, M-F | BAS | VAV AHU w/ Reheat, CHW Clg, Steam Htg | 3600 | 720 | - | - | 25 | 91.7% | Y | 5 | 89.5% | Y | - | - | ||||||||||||||||||||||||||||
| 88 | Food Commissary-Dietetics / Domiciliary S | Penthouse Mechanical Room | Outpatient Clinic East | Outpatient East AHU | Central AHU | McQuay | MMM-214CH | 3JD00303 | 1 | 1998 | 24/7 | BAS | CV MZU, CHW CD, Steam HD | 6960 | 1710 | 1 | 4.8 | 10 | - | ||||||||||||||||||||||||||||||
| 88 | Food Commissary-Dietetics / Domiciliary S | Penthouse Mechanical Room | Outpatient Clinic West | Outpatient West AHU | Central AHU | McQuay | MMM222CH | 3KC00196 | 1 | 1998 | 24/7 | BAS | CV MZU, CHW CD, Steam HD | 11450 | 1680 | 1 | 5.1 | 20 | - | ||||||||||||||||||||||||||||||
| 88 | Food Commissary-Dietetics / Domiciliary S | 2nd Floor Roof | AHU-1: Com AHU and AHU-2: Auditorium | Chiller 3 | Chiller | Trane | CGAM 100A 2C02 AXD2 A1A1 A1AX XA2C 1A4X XAXX XA1A 3X1D XXXL XS | U11D21980 | 1 | 2012 | Cooling Season | BAS - needs to be connected | Air Cooled | 100 | - | - | - | - | 1.01 | 100.5 | - | - | - | ||||||||||||||||||||||||||
| 88 | Food Commissary-Dietetics / Domiciliary S | 2nd Floor Roof South | Domiciliary | Chiller 6 | Chiller | Trane | CGAM 070A 2C02 AXD2 A1A1 A1AX XA1C 1A4X XAXX XA1A 3X1D XXXL XX | U11C21487 | 1 | 2011 | 24/7 | Local Control (to be connected to BAS) | Air Cooled Scroll | 66.5 | R-410A | 159 | 54 | 44 | 1.25 | 83.4 | - | N | - | 3 | |||||||||||||||||||||||||
| 88 | Food Commissary-Dietetics / Domiciliary S | Outside - Ground Level | Outpatient Clinic AHUs | Chiller 2 | Chiller | Carrier | 30GT-060---500KA | 2494F01327 | 1 | 1998 | 24/7 | BAS | Air Cooled | 60 | R-22 | - | - | - | - | - | - | - | - | ||||||||||||||||||||||||||
| 88 | Food Commissary-Dietetics / Domiciliary S | Outside - Ground Level | AHU-1 Tray Line; AHU-2 Kitchen | Chiller 4 | Chiller | Trane | CGAM 070A 2C02 AXD2 A1A1 A1AX XA1C 1A4X XAXX XA1A 3X1D XXXL XX | U11C21488 | 1 | 2011 | 4am to 9pm, M-Sat | BAS | Air Cooled | 64.4 | R-410A | 155 | 54 | 44 | 0.93 | 60.1 | - | N | 4 | ||||||||||||||||||||||||||
| 88 | Food Commissary-Dietetics / Domiciliary S | Roof | Kitchen Make-up Air | KMU-1 | Make-up air unit | - | no plate visible | - | 1 | 1990's | 24/7 | BAS - offline | CV AHU, Steam Htg, 100% OA | 5220 | - | - | - | 3 | - | ||||||||||||||||||||||||||||||
| 88 | Food Commissary-Dietetics / Domiciliary S | Roof | Kitchen Make-up Air | KMU-2 | Make-up air unit | - | no plate visible | - | 1 | 1990's | 24/7 | BAS | CV AHU, Steam Htg, 100% OA | 3480 | - | - | - | 1.5 | - | ||||||||||||||||||||||||||||||
| 88 | Food Commissary-Dietetics / Domiciliary S | Outside - Ground Level | AHU-1 Tray Line; AHU-2 Kitchen | Chiller 5 | Chiller | Trane | CGAM 070A 2C02 AXD2 A1A1 A1AX XA1C 1A4X XAXX XA1A 3X1D XXXL XX | U11C21489 | 1 | 2011 | 4am to 9pm, M-Sat | BAS | Air Cooled | 64.4 | R-410A | 155 | 54 | 44 | 0.93 | 60.1 | - | N | 4 | ||||||||||||||||||||||||||
| 88 | Food Commissary-Dietetics / Domiciliary S | Roof | Medical Administration Office | RTU-2 | Packaged RTU | Trane | TSC036E3REA16G0C1A1B20301 | 110610114L | 1 | 2012 | 7am to 6pm, M-F | Local Control (to be connected to BAS) | Pkgd CV AHU, DX Clg, Elec Htg | 1200 | 180 | 1.25 | - | 1.5 | - | ||||||||||||||||||||||||||||||
| 88 | Food Commissary-Dietetics / Domiciliary S | Roof | Domiciliary Offices 1st Floor | RTU-3 | Packaged RTU | Trane | TSC120E3RGB0YG0C1A1B20101 | 110610164L | 1 | 2012 | 7am to 6pm, M-F | Local Control (to be connected to BAS) | Pkgd CV AHU, DX Clg, Elec Htg | 4000 | 600 | 1.0 | - | 3 | - | ||||||||||||||||||||||||||||||
| 88 | Food Commissary-Dietetics / Domiciliary S | Test Kitchen | Test Kitchen | Test Kitchen AC | Split-System AC | - | no plate visible | - | 1 | 2002 | 24/7 | Local Control | CV Split System ACU, DX Clg | - | - | - | - | 1/6 | - | ||||||||||||||||||||||||||||||
| 88 | Food Commissary-Dietetics / Domiciliary S | Basement Mech Room | Retherm Kitchen | Retherm AC | Split-System AC | York | - | 03-102201-0101 | 1 | 2002 | 12am to 8pm, 7 days/wk | BAS | Pkgd CV AHU, DX Clg, Steam Htg | - | - | - | - | 10 | - | ||||||||||||||||||||||||||||||
| 89 | Administration Building & Nursing Care | 3rd floor Mechancial Roof | Building 89 Audiology | AHU | Central AHU | Temtrol | ITF-DHII | 2011 | |||||||||||||||||||||||||||||||||||||||||
| 89 | Administration Building & Nursing Care | 3rd Floor Mechanical Room | Building 89 Rehabilitation | AHU-1 | Central AHU | Titus | IAH42X66 | 2016 | |||||||||||||||||||||||||||||||||||||||||
| 89 | Administration Building & Nursing Care | Penthouse Mechanical Room - 6th Floor | Chiller 1 | CHWP-1 & -2 | CHW Pump | Armstrong | 4X3X11.5 4030 | - | 2 | 1990's | Cooling Season | BAS | 15 | No | 90% | 300 | 95 | ||||||||||||||||||||||||||||||||
| 88 | Food Commissary-Dietetics / Domiciliary S | 2nd Floor Mechanical Room | Chiller 2 - Outpatient Clinic | CHWP-1 & -2 | CHW Pump | - | - | - | 2 | 1990's | 24/7 | BAS | 5 | No | 82% | - | - | ||||||||||||||||||||||||||||||||
| 88 | Food Commissary-Dietetics / Domiciliary S | 2nd Floor Mechanical Room | Chiller 3 | CHWP-1 & -2 | CHW Pump | Weinman | - | - | 2 | 1990's | Cooling Season | BAS | 7.5 | No | 90% | 120 | 70 | ||||||||||||||||||||||||||||||||
| 88 | Food Commissary-Dietetics / Domiciliary S | 2nd Floor - Domicillary Closet | Chiller 6 | CHWP-1 | CHW Pump | - | - | - | 1 | 1990's | 24/7 | Local Control (to be connected to BAS) | 5 | No | 82% | - | - | ||||||||||||||||||||||||||||||||
| 88 | Food Commissary-Dietetics / Domiciliary S | Main Mechanical Room | Chillers 4 & 5 | CHWP-1 | CHW Pump | Armstrong | 3X2X13 4030 | - | 1 | 1990's | 4am to 9pm, M-Sat | BAS | 15 | No | 90% | 200 | 20 | ||||||||||||||||||||||||||||||||
| 88 | Food Commissary-Dietetics / Domiciliary S | Main Mechanical Room | Chillers 4 & 5 | CHWP-2 | CHW Pump | Armstrong | 3X2X13 4030 | - | 1 | 1990's | 4am to 9pm, M-Sat | BAS | 15 | No | 90% | 200 | 20 | ||||||||||||||||||||||||||||||||
| 88 | Food Commissary-Dietetics / Domiciliary S | Main Mechanical Room | Chillers 4 & 5 | CHWP-3 | CHW Pump | Armstrong | 3X2X13 4030 | 64639 | 1 | 1990's | 4am to 9pm, M-Sat | BAS | 15 | No | 90% | 200 | 20 | ||||||||||||||||||||||||||||||||
| 64 | Boiler Plant | Boiler Plant | Boiler Plant | T-1 | Condensate Tank | Superior Boiler | MS S1600D | 21070096 | 1 | 2021 | |||||||||||||||||||||||||||||||||||||||
| 64 | Boiler Plant | Boiler Plant | Boiler Plant | 64-P-4 | Condensate Transfer Pump | Grundfos | CR 32-2-2-A-G-A-E-HQQE | 1 | 2021 | 10 | 140 | ||||||||||||||||||||||||||||||||||||||
| 64 | Boiler Plant | Boiler Plant | Boiler Plant | 64-P5 | Condensate Transfer Pump | Grundfos | CR 32-2-2-A-G-A-E-HQQE | 1 | 2021 | 5 | 20 | ||||||||||||||||||||||||||||||||||||||
| 173 | Consolidated Laundry | Roof | AC-2 | AC-2 ACCU | Condensing Unit | Trane | TTA150E400AA | 11045XSPYA | 1 | 2011 | 24/7 | Local Control | Air Cooled | 12.5 | R-410A | 1.1 | 13.6 | - | |||||||||||||||||||||||||||||||
| 89 | Administration Building & Nursing Care | 3rd floor Mechancial Roof | Building 89 Audiology | ACCU | Condensing Unit | Aaon | CCB0173A2BAB00A0 | 2011 | |||||||||||||||||||||||||||||||||||||||||
| 89 | Administration Building & Nursing Care | 3rd Floor Mechanical Room Roof | Building 89 Rehabilitation | ACCU-1 | Condensing Unit | Tempmaster | YJT20C00A4BAE4 | 2016 | |||||||||||||||||||||||||||||||||||||||||
| 88 | Food Commissary-Dietetics / Domiciliary S | Outside Ground Level | Retherm AC | Retherm Condensing Unit | Condensing Unit | York | HB180C00A2AAA1A | (S)NFLM060177 | 1 | 2002 | 12am to 8pm, 7 days/wk | BAS | Air Cooled | - | R-22 | - | - | - | |||||||||||||||||||||||||||||||
| 89 | Administration Building & Nursing Care | Penthouse Mechanical Room - 6th Floor | 4th & 5th Floors | AHU-7 | Central AHU | Trane | PSCA048UAAAO | H21K05800A | 1 | 2022 | Cooling Season | BAS | VIV AHU, CHW Clg, Steam Htg, 100% OA | 28600 | 14300 | - | - | 30 | 92.4 | ||||||||||||||||||||||||||||||
| 89 | Administration Building & Nursing Care | Basement Mechanical Room | Canteen | Canteen Condensing Unit | Condensing Unit | Trane | RAUJC60EBE13 | C21K07419 | 1 | 2022 | 7am to 7pm, M-F | BAS | VAV AHU, CHW Clg, Steam Htg | - | - | - | - | 10 | - | ||||||||||||||||||||||||||||||
| 88 | Food Commissary-Dietetics / Domiciliary S | Outside - Ground Level | Volunteer Service | RTU-1 | Condensing Unit | Trane | TSC120E3RGB0YG0C1A1B20101 | 110610211L | 1 | 2011 | 7am to 6pm, M-F | BAS | Pkgd CV AHU, DX Clg, Elec Htg | 4000 | 600 | 1.0 | - | 3 | - | ||||||||||||||||||||||||||||||
| 64 | Boiler Plant | Boiler Plant | Boiler Plant | H-1 | Dearator Tank | Superior Boiler | MSTC050T165-135 | 21070095 | 1 | 2021 | |||||||||||||||||||||||||||||||||||||||
| 86 | Intermediate Care - Wards C and D | Basement MER - Bldg 88 | Bldg 85 -86 | - | DHW Pump | - | - | - | 2 | - | 24/7 | BAS | - | - | - | - | - | ||||||||||||||||||||||||||||||||
| 87 | Nursing Care – Ward B | Room B4 | Bldg 87 | - | DHW Pump | - | - | - | 1 | - | 24/7 | BAS | - | - | - | - | - | ||||||||||||||||||||||||||||||||
| 88 | Food Commissary-Dietetics / Domiciliary S | Main Mechanical Room | Bldg 88 | DHW Pumps-1 & -2 | DHW Pump | Goulds Pumps, ITT | NPE 1 1/4 X 1 1/2 - 6 | 2ST1D2F4 | 2 | - | 24/9 | BAS | - | - | - | - | - | ||||||||||||||||||||||||||||||||
| 89 | Administration Building & Nursing Care | Basement Mechanical Room | Bldg 89 | DHW Pumps-1 & -2 | DHW Pump | - | - | - | 2 | - | 24/7 | BAS | - | - | - | - | - | ||||||||||||||||||||||||||||||||
| 173 | Consolidated Laundry | Mechanical Room | Laundry | DHW Pumps-1, -2, & -3 | DHW Pump | Marathon | unreadable | - | 3 | 1983 | 24/7 | Local Control | - | - | - | - | - | ||||||||||||||||||||||||||||||||
| 85 | Intermediate Care - Wards C and D | Bldg 85 Roof | Bldg 85 | EF-1 (Bldg 85 Toilet Exhaust) | Exhaust Fan | Dayton | 4YY10 | 11098186 0711 | 1 | 2005 | 24/7 | BAS | |||||||||||||||||||||||||||||||||||||
| 86 | Intermediate Care - Wards C and D | Bldg 86 Roof | Bldg 86 | EF-2 (Bldg 86 Toilet Exhaust) | Exhaust Fan | Greenheck | GB-260-20 | 00A28131 | 1 | 2005 | 24/7 | BAS | |||||||||||||||||||||||||||||||||||||
| 173 | Consolidated Laundry | High Roof | Clean Area | E-1 | Exhaust Fan | - | - | - | 1 | 1983 | 4:30am to 6pm, M-F | Time Clock - Local Control | |||||||||||||||||||||||||||||||||||||
| 173 | Consolidated Laundry | High Roof | Clean Area | E-2 | Exhaust Fan | York | CS490FOAF Y-E-2 | 84-803423-E-H-5 | 1 | 1983 | 4:30am to 6pm, M-F | Time Clock - Local Control | |||||||||||||||||||||||||||||||||||||
| 173 | Consolidated Laundry | High Roof | Clean Area | E-3 | Exhaust Fan | - | - | - | 1 | 1983 | 4:30am to 6pm, M-F | Time Clock - Local Control | |||||||||||||||||||||||||||||||||||||
| 173 | Consolidated Laundry | Equipment Room | Equipment Room | E-8 | Exhaust Fan | - | - | - | 1 | 1983 | 24/7 | Local Control | |||||||||||||||||||||||||||||||||||||
| 173 | Consolidated Laundry | Utility Mechanical Room | Laundry | E-1 Central Exhaust | Exhaust Fan | York | CS113FOAF Y-AC-2 | 83-803423-D-H-4 | 1 | 1983 | 4:30am to 6pm, M-F | Time Clock - Local Control | |||||||||||||||||||||||||||||||||||||
| 173 | Consolidated Laundry | Low Roof | Laundry Equipment Room | E-7 | Exhaust Fan | - | - | - | 1 | 1983 | 24/7 | Local Control | |||||||||||||||||||||||||||||||||||||
| 173 | Consolidated Laundry | Low Roof | Locker Rooms | E-6 | Exhaust Fan | - | - | - | 1 | 1983 | 24/7 | Local Control | |||||||||||||||||||||||||||||||||||||
| 173 | Consolidated Laundry | Clerestory | Mechanics Shop & Break Room | E-10 | Exhaust Fan | - | - | - | 1 | 1983 | 24/7 | Local Control | |||||||||||||||||||||||||||||||||||||
| 173 | Consolidated Laundry | Low Roof | Soiled Area | E-1A | Exhaust Fan | Energenics | 140 | 2313A1000 | 1 | 1983 | 24/7 | Time Clock - Local Control | |||||||||||||||||||||||||||||||||||||
| 173 | Consolidated Laundry | Low Roof | Soiled Area | E-2A | Exhaust Fan | Dayton | 36Y66G | 11417518 0807 | 1 | 1983 | 24/7 | Time Clock - Local Control | |||||||||||||||||||||||||||||||||||||
| 173 | Consolidated Laundry | High Roof | Tunnel | E-A | Exhaust Fan | - | - | - | 1 | 1983 | 24/7 | Local Control | |||||||||||||||||||||||||||||||||||||
| 173 | Consolidated Laundry | High Roof | Tunnel | E-B | Exhaust Fan | - | - | - | 1 | 1983 | 24/7 | Local Control | |||||||||||||||||||||||||||||||||||||
| 173 | Consolidated Laundry | High Roof | Tunnel | E-C | Exhaust Fan | - | - | - | 1 | 1983 | 24/7 | Local Control | |||||||||||||||||||||||||||||||||||||
| 88 | Food Commissary-Dietetics / Domiciliary S | 2nd & 3rd Floor Ceilings | Domiciliary Rooms | FCUs | Fan Coil Units | - | - | - | 15 | - | 24/7 | Local Control | |||||||||||||||||||||||||||||||||||||
| 64 | Boiler Plant | Boiler Plant | Boiler Plant | 64-P-6 | Fuel oil Pump | Industrial Fuel Systems | 3D187Y | 25357 | 1 | 2021 | 5 | 20 | |||||||||||||||||||||||||||||||||||||
| 64 | Boiler Plant | Boiler Plant | Boiler Plant | 64-P-7 | Fuel oil Pump | Industrial Fuel Systems | 3D187Y | 25357 | 1 | 2021 | |||||||||||||||||||||||||||||||||||||||
| 64 | Boiler Plant | Boiler Plant | Boiler Plant | 64-P-1 | FW Pump | Grundfos | CR 15-7A-F-A-E-HQQE | 1 | 2021 | 50 | 140 | ||||||||||||||||||||||||||||||||||||||
| 64 | Boiler Plant | Boiler Plant | Boiler Plant | 64-P-2 | FW Pump | Grundfos | CR 15-7A-F-A-E-HQQE | 1 | 2021 | 50 | 140 | ||||||||||||||||||||||||||||||||||||||
| 64 | Boiler Plant | Boiler Plant | Boiler Plant | 64-P-3 | FW Pump | Grundfos | CR 15-7A-F-A-E-HQQE | 1 | 2021 | 10 | 140 | ||||||||||||||||||||||||||||||||||||||
| 86 | Intermediate Care - Wards C and D | Bldg 86 Basement Mechanical Room | Bldg 85 - 86 | DHW HX-1, DHW HX-2 | Heat Exchanger | FloRite | - | - | 2 | - | 24/7 | BAS | |||||||||||||||||||||||||||||||||||||
| 87 | Nursing Care – Ward B | Room B4 | Bldg 87 | DHW HX-1, DHW HX-2 | Heat Exchanger | FloRite | - | - | 2 | - | 24/7 | BAS | |||||||||||||||||||||||||||||||||||||
| 88 | Food Commissary-Dietetics / Domiciliary S | Main Mechanical Room | Bldg 88 | DHW HX-1, DHW HX-2 | Heat Exchanger | Armstrong | 665 | 9133 | 2 | - | 24/8 | BAS | |||||||||||||||||||||||||||||||||||||
| 89 | Administration Building & Nursing Care | Basement Mechanical Room A-20 | Food Tray line | AHU-1 | Central AHU | York | AP150FSFC(…unreadable) | SHDM-00939T | 1 | 1998 | 24/7 | BAS | CV AHU, CHW Clg, Steam Htg, 100% OA | 6875 | 6875 | - | 1.75 | 5 | - | ||||||||||||||||||||||||||||||
| 89 | Administration Building & Nursing Care | Ceiling - Laundry Storage | Linen | HV-2 | Central AHU | York | Coil Model DA0100630.00x048G01HD035S000DH01L CS01BM2.0007.00ANA99SR | DANM-20072B | 1 | 1998 | 5am to 6pm, 7 days/wk | BAS | CV AHU, Steam Htg, 100% OA | 2880 | 2880 | - | - | 2 | - | ||||||||||||||||||||||||||||||
| 89 | Administration Building & Nursing Care | Roof | AHU-7 | Chiller 1 | Chiller | Trane | CGAM 130A 2C02 AXD2 A1A1 A1AX XA1A 1A4X XAXX XA1A 3X1D XXXL XXXX | U11C21490 | 1 | 2011 | Cooling Season | BAS | Air Cooled | 124.7 | R-410A | 300 | 54 | 44 | 1.25 | 155.9 | - | N | 6 | ||||||||||||||||||||||||||
| 89 | Administration Building & Nursing Care | Outside - Ground Level | Canteen AHU | Canteen Chiller | Chiller | Carrier | 30GT-020---510 | 1895F46287 | 1 | 1990's | 7am to 7pm, M-F | BAS | Air Cooled | 20 | R-22 | - | - | - | - | - | - | N | |||||||||||||||||||||||||||
| 89 | Administration Building & Nursing Care | Outside - Ground Level | Sterile Processing - Basement | Sterile Processing AHU | Packaged AHU | Carrier | 50HJ-007---521-- | 2195G20672 | 1 | 1990's | 24/7 | Local Control | Air Cooled | 6 | R-22 | 1.12 | 6.7 | - | Pkgd CV AHU, DX Clg Only | - | - | - | - | 3 | - | ||||||||||||||||||||||||
| 89 | Administration Building & Nursing Care | 2nd Floor Mechanical Room | Dining Room | SCAC-1 | Split-System AC | York | H2CA360A24B | NAEM007913 | 1 | 1998 | 6am to 8pm, 7 days/wk | BAS | VIV AHU, DX, Steam Htg | 10000 | 2000 | - | - | 7.5 | - | ||||||||||||||||||||||||||||||
| 89 | Administration Building & Nursing Care | 2nd Floor Ladies room Mech Room | Dining Room Pub | SCAC-2 | Split-System AC | - | - | - | 1 | 1998 | 6am to 8pm, 7 days/wk | BAS | CV AHU, Split DX Clg, Steam Htg | 2000 | 400 | - | - | 1 | - | ||||||||||||||||||||||||||||||
| 89 | Administration Building & Nursing Care | AC: Inside; ACCU: Outside - Ground Level | Pharmacy East - 1st Floor | Pharmacy East AC | Split-System AC | Carrier | 38AR-007-501 | 0407G30121 | 1 | 2001 | 24/7 | Local Control | Air Cooled | 6 | R-22 | 1.20 | 7.2 | - | CV Split System ACU, DX Clg | - | - | - | - | 1/3 | - | ||||||||||||||||||||||||
| 89 | Administration Building & Nursing Care | AC: Inside; ACCU: Outside - Ground Level | Pharmacy West - 1st Floor | Pharmacy West AC | Split-System AC | Carrier | 38AK-007-501 | 1495G00131 | 1 | 2001 | 24/7 | Local Control | Air Cooled | 6 | R-22 | 1.20 | 7.2 | - | CV Split System ACU, DX Clg | - | - | - | - | 1 | - | ||||||||||||||||||||||||
| 89 | Administration Building & Nursing Care | AC: Inside; ACCU: Outside - Ground Level | PID Room - 1st Floor | PID ACU | Split-System AC | Rheem ACCU | - | - | 1 | 1990's | Cooling Season | Local Control | Air Cooled | 5 | R-22 | 1.20 | 6.0 | - | CV Split System ACU, DX Clg | - | - | - | - | 1/3 | - | ||||||||||||||||||||||||
| 89 | Administration Building & Nursing Care | Outside - Ground Level | Telephone Room | Telephone Room AC | Split-System AC | Layton | LARKIN PFG5 | 88643591 1 | 1 | 2004 | 24/7 | Local Control | Air Cooled | - | R-22 | - | - | - | CV Split System ACU, DX Clg | - | - | - | - | 2 | - | ||||||||||||||||||||||||
| 89 | Administration Building & Nursing Care | Outside - Ground Level | Telephone Room | Telephone room Backup | Split-System AC | Inter-City Products | AD060HD | L920966610 | 1 | 1992 | Backup to Tele. Room AC | Local Control | Air Cooled | - | R-22 | - | - | - | CV Split System ACU, DX Clg | - | - | - | - | 3/4 | - | ||||||||||||||||||||||||
| 173 | Consolidated Laundry | Mezzanine Mechanical Room | Clean Area Process Equipment | HV-2 | Central AHU | York | CS490FOAV Y-HV-2 | 84-803424-B-H-2 | 1 | 1983 | 24/7 | Time Clock - Local Control | CV AHU, Steam Htg, 100% OA | 29990/14995 | 29990/14995 | - | - | 40 | - | ||||||||||||||||||||||||||||||
| 173 | Consolidated Laundry | Mezzanine Mechanical Room | Clean Area Process Equipment | HV-3 | Central AHU | York | CS490FOAF Y-HV-2 | 84-803423-B-H-2 | 1 | 1983 | 4:30am to 6pm, M-F | Time Clock - Local Control | CV AHU, Steam Htg, 100% OA | 29990/14995 | 29990/14995 | - | - | 40 | - | ||||||||||||||||||||||||||||||
| 173 | Consolidated Laundry | Mezzanine Mechanical Room | Clean Area Process Equipment | HV-4 | Central AHU | York | CS490FOAF Y-HV-4 | 83-803423-C-H-3 | 1 | 1983 | 4:30am to 6pm, M-F | Time Clock - Local Control | CV AHU, Steam Htg, 100% OA | 29990/14995 | 29990/14995 | - | - | 40 | - | ||||||||||||||||||||||||||||||
| 173 | Consolidated Laundry | Mezzanine Mechanical Room | Mechanics Shop & Break Room | AC-2 | Central AHU | York | CS113FOAF | Y-AC-2 | 1 | 1983 | 24/7 | Local Control | CV AHU, Split DX Clg, Steam Htg | 3000 | 300 | - | - | 2 | - | ||||||||||||||||||||||||||||||
| 173 | Consolidated Laundry | Mezzanine Mechanical Room | Soiled Laundry Area | HV-1 | Central AHU | York | CS490FOAF Y-HV-1 | 84-803423-A-H-1 | 1 | 1983 | 24/7 | Time Clock - Local Control | CV AHU, Steam Htg, 100% OA | 29990 | 29990 | - | - | 40 | - | ||||||||||||||||||||||||||||||
| 173 | Consolidated Laundry | Roof | Offices | RTU-4 | Packaged RTU | Trane | TSC092E4RCA11G0C1A1B20101 | 110610174L | 1 | 2011 | 7am to 6pm, M-F | BAS | Pkgd CV AHU, DX Clg, Elec Htg | 3000 | 450 | 1.0 | - | 3 | - | ||||||||||||||||||||||||||||||
| 85/86 | Intermediate Care - Wards C and D | Building Perimeter | Bldg 85 -86 | Steam Radiators | Steam Radiator | - | - | - | - | 1948 | Heating Season | Local Control | |||||||||||||||||||||||||||||||||||||
| 87 | Nursing Care – Ward B | Building Perimeter | Bldg 87 | Steam Radiators | Steam Radiator | - | - | - | - | 1948 | Heating Season | Local Control | |||||||||||||||||||||||||||||||||||||
| 88 | Food Commissary-Dietetics / Domiciliary S | Building Perimeter | Bldg 88 | Steam Radiators | Steam Radiator | - | - | - | - | 1948 | Heating Season | Local Control | |||||||||||||||||||||||||||||||||||||
| 89 | Administration Building & Nursing Care | Building Perimeter | Bldg 89 | Steam Radiators | Steam Radiator | - | - | - | - | 1948 | Heating Season | Local Control | |||||||||||||||||||||||||||||||||||||
| 89 | Administration Building & Nursing Care | Basement Mechanical Room | Bldg 89 | DHW HX-1, DHW HX-2 | Storage Tank - Heat Exchanger | - | - | - | 2 | - | 24/7 | BAS | |||||||||||||||||||||||||||||||||||||
| 173 | Consolidated Laundry | Mechanical Room | Laundry | DHW HX-1, DHW HX-2 | Storage Tank - Heat Exchanger | unreadable | - | 2 | 1983 | 24/7 | Local Control | ||||||||||||||||||||||||||||||||||||||
| 64 | Boiler Plant | Boiler Plant | All Buildings | Boiler 1 | Water Tube Boiler | Victory | DT-2-33 SP | 15806-1 | 1 | 2021 | |||||||||||||||||||||||||||||||||||||||
| 64 | Boiler Plant | Boiler Plant | All Buildings | Boiler 2 | Water Tube Boiler | Victory | DT-2-33 SP | 15806-2 | 1 | 2019 | |||||||||||||||||||||||||||||||||||||||
| 64 | Boiler Plant | Boiler Plant | All Buildings | Boiler 3 | Water Tube Boiler | Victory | DT-2-33 SP | 15806-3 | 1 | 2019 | 50 | 140 | |||||||||||||||||||||||||||||||||||||
| 86 | Intermediate Care - Wards C and D | Window-mounted | Building Spaces along Perimeter - 1st floor | WACs | Window AC Unit | Friedrich | - | - | 1 | - | 24/7 | Local Control | |||||||||||||||||||||||||||||||||||||
| 87 | Nursing Care – Ward B | Window-mounted | Building Spaces along Perimeter - 1st floor | WACs | Window AC Unit | Friedrich | - | - | 6 | - | 24/7 | Local Control | |||||||||||||||||||||||||||||||||||||
| 88 | Food Commissary-Dietetics / Domiciliary S | Building Perimeter | Building Spaces along Perimeter - 1st floor | WACs | Window AC Unit | Friedrich | - | - | 32 | - | 24/7 | Local Control | |||||||||||||||||||||||||||||||||||||
| 89 | Administration Building & Nursing Care | Building Perimeter | Building Spaces along Perimeter - 1st floor | WACs | Window AC Unit | Friedrich | - | - | 31 | - | 24/7 | Local Control | |||||||||||||||||||||||||||||||||||||
| 85 | Intermediate Care - Wards C and D | Window-mounted | Building Spaces along Perimeter - 2nd floor | WACs | Window AC Unit | Friedrich | - | - | 11 | - | 24/7 | Local Control | |||||||||||||||||||||||||||||||||||||
| 86 | Intermediate Care - Wards C and D | Window-mounted | Building Spaces along Perimeter - 2nd floor | WACs | Window AC Unit | Friedrich | - | - | 14 | - | 24/7 | Local Control | |||||||||||||||||||||||||||||||||||||
| 88 | Food Commissary-Dietetics / Domiciliary S | Building Perimeter | Building Spaces along Perimeter - 2nd floor | WACs | Window AC Unit | Friedrich | - | - | 13 | - | 24/7 | Local Control | |||||||||||||||||||||||||||||||||||||
| 89 | Administration Building & Nursing Care | Building Perimeter | Building Spaces along Perimeter - 2nd floor | WACs | Window AC Unit | Friedrich | - | - | 18 | - | 24/7 | Local Control | |||||||||||||||||||||||||||||||||||||
| 85 | Intermediate Care - Wards C and D | Window-mounted | Building Spaces along Perimeter - 3rd floor | WACs | Window AC Unit | Friedrich | - | - | 10 | - | 24/7 | Local Control | |||||||||||||||||||||||||||||||||||||
| 86 | Intermediate Care - Wards C and D | Window-mounted | Building Spaces along Perimeter - 3rd floor | WACs | Window AC Unit | Friedrich | - | - | 13 | - | 24/7 | Local Control | |||||||||||||||||||||||||||||||||||||
| 89 | Administration Building & Nursing Care | Building Perimeter | Building Spaces along Perimeter - 3rd Floor | WACs | Window AC Unit | Friedrich | - | - | 33 | - | 24/7 | Local Control | |||||||||||||||||||||||||||||||||||||
| 89 | Administration Building & Nursing Care | Building Perimeter | Building Spaces along Perimeter - 5th Floor | WACs | Window AC Unit | Friedrich | - | - | 8 | - | 24/7 | Local Control | |||||||||||||||||||||||||||||||||||||
| 89 | Administration Building & Nursing Care | Building Perimeter | Building Spaces along Perimeter - 6th Floor | WACs | Window AC Unit | Friedrich | - | - | 22 | - | 24/7 | Local Control | |||||||||||||||||||||||||||||||||||||
| 88 | Food Commissary-Dietetics / Domiciliary S | Building Perimeter | Building Spaces along Perimeter - Basement | WACs | Window AC Unit | Friedrich | - | - | 7 | - | 24/7 | Local Control | |||||||||||||||||||||||||||||||||||||
| 89 | Administration Building & Nursing Care | Building Perimeter | Building Spaces along Perimeter - Basement | WACs | Window AC Unit | Friedrich | - | - | 11 | - | 24/7 | Local Control |
| - | - | - | - | - | - | |
| FOR REFERENCE ONLY. CONTRACTOR TO VERIFY ON-SITE. |