626_N_East_E02_–_ELECTRICAL_TO_CODE__(1).docx

DOCX document 199 KB Posted

Attached to
626 N EAST ST - ELECTRICAL TO CODE
Solicitation number
2026-COMMUNITY DEVELOPMENT-035
Issued by
Kalamazoo County, Huntington Woods City, Michigan

About this file

This is a Work Write-Up document prepared by the City of Jackson Community Development Department for electrical repairs at 626 N East Avenue, Jackson, Michigan 49202. The project, designated E02 - ELECTRICAL TO CODE, is a single unit electrical rehabilitation scope addressing code violations and hazardous conditions at a residential property owned by Deborah Keena. The work includes installation of hardwired smoke and carbon monoxide detectors with interconnect capability in the basement, new dedicated circuits for furnace, air conditioning unit, water heater, kitchen, and bathroom, basement GFCI outlet installation, re-running of 220-line service per Michigan Residential Code 2015 specifications, installation of proper electrical connectors, and four service lights in the basement spaced according to code requirements. All work must comply with Housing Code and Electrical Regulations for existing structures. The electrical contractor is responsible for wall and ceiling repairs from any holes created during wire installation, with repairs to be smooth, sanded, and ready for painting. The document was prepared on June 30, 2026, with the property location listed as unassigned at the time of preparation.

The work scope includes a fixture allowance of $500.00 incorporated into the bid price, with any wire mold or similar exposed wiring installations in living areas requiring a change order executed by the Rehabilitation Specialist prior to installation. A permit is required for this project, and the contractor must obtain proper licensing and complete SAM.gov registration prior to bid submission. The project is awarded through competitive sealed bidding to the qualified lowest bidder. The electrical contractor bears responsibility for daily cleanup and ensuring all new outlets are wired with constant feed unless specifically designated for switched lighting. Owner is responsible for final painting of repaired surfaces.

View the file

Other files

File Type Posted
626_N_EAST_ST_-_ELECTRICAL_TO_CODE.pdf PDF
Labor_and_Material_Payment_Bond.pdf PDF
Performance_Bond.pdf PDF
Maintenance_and_Guarantee_Bond.pdf PDF
All_Services_Sample_Contract_.docx DOCX document

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Work Write-Up

E02 – ELECTRICAL TO CODE

* EXHIBIT 1 *

Dated: 6/30/2026

CUSTOMER INFORMATION

Keena, Deborah 626 N East Ave , Jackson, MI 49202-3421

PREPARED BY

sharrison@cityofjackson.org

* NOTE *

THE CUSTOMER AND CONTRACTOR MUST SIGN THE BOTTOM OF EACH PAGE ONLY IF

1) THIS WORK WRITE-UP BECOMES PART OF A CONSTRUCTION CONTRACT

2) THE UNDERSIGNED CUSTOMER AND CONTRACTOR HAVE REVIEWED, APPROVED AND AGREED TO THE WORK AND PRICES DESCRIBED IN THIS WORK WRITE-UP

Location: Unassigned

Electrical System
Quantity
Units
Total

1 - E02 – ELECTRICAL TO CODE

(Specification ID:80.00000 )

EA

* PERMIT REQUIRED *

Correct all existing violations or hazardous conditions existing in this structure as specified in the Housing Code and Electrical Regulations as to existing structures, as well as those included below.

I, the Electrical Contractor, shall perform the following alterations or installations stated below and shall further assure that upon completion, the structure shall be in compliance with the respective codes and permit requirements for the agreed contract price.

A change order must be executed by the Rehabilitation Specialist prior to installation of any "wire mold" or similar exposed wiring in living areas. • Fixture allowance included in bid: $ 500.00. See specs for additional electrical items.

Note: Electrical Contractor shall be responsible for all wall and ceiling repairs from any holes that were needed to run wire. Wall repairs shall be smooth, and sanded and ready for paint, owner responsible for painting. Repair of holes shall be done with plaster so as to match the existing materials.

Contractor responsible for daily cleanup.

All new outlets shall be wired with a constant feed unless specifically listed to provide switched lighting.

To include the following.

1: Install of a hard wire smoke and carbon monoxide detector in basement, to include interconnected if hardwire cannot be done, then radio frequency interconnect with 10-year lithium battery. Smokes according to MRC 2015.

2: New dedicated circuit for furnace. and AC unit 3: Basement, One GFCI outlet at the service panel and one replacement of the outlet at the washer.

4: New dedicated circuit for the water heater 5: Remove and re-run 220 line using the 6 / 12 rule of the MRC 2015.

6: Kitchen, install of dedicated 20-amp circuits with GFCI protection and receptacles spaced according to chapter 39 of the MRC.

7: Bathroom, install dedicated 20-amp circuit with GFCI protection and lights 8: Install of proper electrical connectors for box. See picture.

9: Basement, Install of four service lights. One within 10ft the service panel, one within 10ft of the furnace, the other two spaced evenly in remaining space.

Electrical Contractor Name:

Permit Number:

Total

Prepared By: sharrison@cityofjackson.org on 6/30/2026

OWNER ACCEPTS SCOPE OF WORK

I have read the contents of this work write up and received a copy. I fully understand the repairs to be made to my property.

x___________________________________
Owner:Date

CONTRACTOR ACCEPTS SCOPE OF WORK

I have read the contents of this work write up and agree to perform all work called for in accordance with the bid submitted on __________.

x___________________________________
ContractorDate
x______________________________________
Construction SpecialistDate
Prepared By: sharrison@cityofjackson.org on 6/30/2026
5 of 5

image1.png image2.png

File details come from the government source that posted it. Updated .