This is an Asbestos Inspection Report prepared by Air Quality Consulting LLC for the Department of Facilities, Construction and Management (DFCM) on the Otter Creek Maintenance Building located at 480 Highway UT-22, Antimony, Utah. The inspection was conducted on August 21, 2026, by AQC Certified Inspectors Scott Bainbridge (ASB-6822), Jaden Ford (ASB-8971), and Preston Bainbridge (ASB-8870) in accordance with Utah Department of Air Quality regulations and EPA and OSHA requirements. The inspection scope covered areas to be disturbed by an HVAC renovation project involving wall and ceiling penetrations. Five samples were collected from the office, bathrooms, exterior walls, and ceiling systems spanning approximately 7,060 square feet of drywall and insulation materials. The inspection report is valid for three years from the inspection date and must remain onsite and accessible during all renovation or demolition activities.
Laboratory analysis was conducted by Eurofins Reservoirs using Polarized Light Microscopy (PLM) and Transmission Electron Microscopy (TEM) methods. All five samples tested negative for asbestos-containing materials (ND results across all samples), indicating no ACM present in the areas to be disturbed by the HVAC project. Sample materials included gray/tan drywall, white compound, off-white/tan drywall, yellow insulation with wrap, and white/silver wrap, all yielding non-detectable asbestos results. The report notes that quantities are estimates to be verified by the bidding contractor and that work should cease if any suspect materials not identified in the report are discovered during renovation or demolition activities. The report emphasizes that it applies only to the identified scope of work and cannot be used for any activities outside those parameters.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Asbestos Inspection Report Department of Facilities, Construction and Management
Otter Creek Maintenance Building 480 Hwy UT-22, Antimony, Utah 84712
August 21, 2026
AQC Certified Inspectors
Air Quality Consulting LLC
ASBC-603
This inspection is valid for three (3) years from the above date, if this report is expired you will need to have a currently certified inspector assess the report and provide a letter of renewal or reinspect. See UDAQ R307-807-6
Scott Bainbridge
ASB-6822
Jaden Ford
ASB-8971
Preston Bainbridge
ASB-8870
Jaden Ford
The quantities within this report are estimates and should be verified by any bidding contractor. If any suspect materials not identified in this report, that will be disturbed, are found during any renovation or demolition, work should stop and the material assumed or tested by a certified asbestos inspector.
Scope of Work
This inspection was performed in accordance with Utah Department of Air Quality (DAQ) as found in the Utah Air Quality Rule R307-801-10, which also covers all Environmental Protection Agency (EPA) and Ocupational Safety and Health Agency (OSHA) requirements. This inspection report is required to be onsite and accessible during all renovation or demolition activities. Samples referenced in this report were analyzed by polarized light microscopy (PLM) as outlined in the attached lab results.
We were hired by DFCM to inspect the buidling for an HVAC project that will meke penetrations into wall and ceiling systems.
Underneath the foundation is inaccessible and may contain suspect materials.
This inspection report only encompasses the areas and materials outlined in the above scope of work. Should the scope of work be altered in any way or materials found that are not identified within this report shall require additional assessment by a certified asbestos inspector. This report cannot be used for any work outside of the above scope of work.
Executive Summary
Building Description
There was no materials that contain ACM in the areas to be disturbed by the renovation in the offices and exterior walls and ceilings.
Unknown
Framed
Metal
Metal
Fiberglass
Drywall Open
Drywall Open
Carpet Vinyl Tile None
OCMB-81926-1 Office ND ND
OCMB-81926-2
Bathroom Exterior ND ND
OCMB-81926-3 Bathroom ND ND
OCMB-81926-4 Exterior Wall ND ND
OCMB-81926-5 Ceiling ND ND
* - Denotes less than 1% asbestos which is regulated by OSHA, it is recommended to review their regulations before removal
* - Denotes less than 1% asbestos which is regulated by OSHA, it is recommended to review their regulations before removal
Age:
Structure:
Roof:
Exterior:
Insulation:
Walls:
Ceilings:
Flooring:
Sampling Data
Image Sample Number
Sample Location Lab Results Category
Drywall System, Office and Bathroom, 760 SF
Insulation, Exterior Walls and Ceiling, 6,300 SF p;ojpoj[ojk['ewf
August 21, 2026
Sincerely, Jeanne Spencer President
Subcontractor Number:
Laboratory Report: RES 779712-1
Project #/P.O. #: OCMB-81926
Project Description: Otter Creek Maintenance Building
Scott Bainbridge Air Quality Consulting, LLC 226 E 4800 S Murray, UT 84107
Dear Scott, Eurofins Reservoirs is an analytical laboratory accredited for the analysis of Industrial Hygiene and Environmental matrices by the National Voluntary Laboratory Accreditation Program (NVLAP), Lab Code 101896-0 for Transmission Electron Microscopy (TEM) and Polarized Light Microscopy (PLM) analysis and the American Industrial Hygiene Association (AIHA LAP), Lab ID 101533 for Phase Contrast Microscopy (PCM) analysis. This laboratory is currently proficient in both Proficiency Testing and PAT programs respectively.
Eurofins Reservoirs has analyzed the following samples for asbestos content as per your request. The analysis has been completed in general accordance with the appropriate methodology as stated in the attached analysis table. The results have been submitted to your office.
RES 779712-1 is the job number assigned to this study. This report is considered highly confidential and the sole property of the customer. Eurofins Reservoirs will not discuss any part of this study with personnel other than those of the client. The results described in this report only apply to the samples analyzed, as received and with the information provided by the customer (i.e. sample volumes and areas). This report must not be used to claim endorsement of products or analytical results by NVLAP or any agency of the U.S. Government. This report shall not be reproduced except in full, without written approval from Eurofins Reservoirs. Samples will be disposed of after sixty days unless longer storage is requested. If you have any questions about this report, please feel free to call 303-964-1986.
by Camryn Baumgartner
08/21/202608/21/202608/21/202608/21/2026
Eurofins Reservoirs Environmental, Inc Eurofins Reservoirs QA Manual
Effective July 28, 2026 Q:\QAQC\Eurofins Reservoirs QA Manual.pdf
(303) 964-1986 https://www.eurofinsus.com/builtenv https://clients.rei.et.eurofinsus.com
4955 Yarrow St, Suite 100, Arvada, CO 80002
Laboratory Sample IDLaboratory Sample IDLaboratory Sample IDLaboratory Sample ID LLLL Asbestos ContentAsbestos ContentAsbestos ContentAsbestos Content Non-Non-Non-Non- Non-Non-Non-Non- AAAA SubSubSubSub AsbestosAsbestosAsbestosAsbestos FibrousFibrousFibrousFibrous YYYY PhysicalPhysicalPhysicalPhysical PartPartPartPart MineralMineralMineralMineral VisualVisualVisualVisual FibrousFibrousFibrousFibrous ComponentsComponentsComponentsComponents EEEE DescriptionDescriptionDescriptionDescription EstimateEstimateEstimateEstimate ComponentsComponentsComponentsComponents
Client Sample NumberClient Sample NumberClient Sample NumberClient Sample Number RRRR (%) (%) (%) (%) 779712 -779712 -779712 -779712 - OCMB-81926-1OCMB-81926-1OCMB-81926-1OCMB-81926-1 A Gray/tan drywall w/ blue/white paint 100 NDNDNDND 15 85.0 779712 -779712 -779712 -779712 - OCMB-81926-2OCMB-81926-2OCMB-81926-2OCMB-81926-2 A White compound w/ gray paint 30 NDNDNDND 0 100.0 B Off-white/tan drywall 70 NDNDNDND 15 85.0 779712 -779712 -779712 -779712 - OCMB-81926-3OCMB-81926-3OCMB-81926-3OCMB-81926-3 A Off-white/tan drywall w/ gray paint 100 NDNDNDND 15 85.0 779712 -779712 -779712 -779712 - OCMB-81926-4OCMB-81926-4OCMB-81926-4OCMB-81926-4 A Yellow insulation w/ white/silver wrap 100 NDNDNDND 65 35.0 779712 -779712 -779712 -779712 - OCMB-81926-5OCMB-81926-5OCMB-81926-5OCMB-81926-5 A White/silver wrap 100 NDNDNDND 15 85.0 TEM Analysis recommended for organically bound material (i.e. floor tile) if PLM results are <1%.
William Spells Analyst
Eurofins Reservoirs Environmental, Inc Eurofins Reservoirs QA Manual
Effective July 28, 2026 Q:\QAQC\Eurofins Reservoirs QA Manual.pdf
Job Number:
Client:
Client Project/P.O.:
Client Project Description:
Date Samples Received:
Analysis Type:
Turnaround:
Date Samples Analyzed:
779712-1 Air Quality Consulting, LLC
OCMB-81926
Otter Creek Maintenance Building August 21, 2026 EPA 600/R-93/116 - Short Report, Bulk Rush August 21, 2026
EUROFINS RESERVOIRS ENVIRONMENTAL, INC
NVLAP Lab Code 101896-0
AIHA LAP, LLC. LAB ID 101533
TABLE: I ANALYSIS: PLM BULK ANALYSIS, PERCENTAGE COMPOSITION BY VOLUME
NA = Not Analyzed NR = Not Received ND = None Detected TR = Trace; <1 % Visual Estimate Trem-Act = Tremolite-Actinolite
(303) 964-1986 https://www.eurofinsus.com/builtenv https://clients.rei.et.eurofinsus.com
SUBMITTED BY INVOICE TO
Client Sample ID Number
RES Job #: 779712
CONTACT INFORMATION SERIES
ASBESTOS LABORATORY REQUESTED ANALYSIS VALID MATRIX CODES LAB NOTES
CHEMISTRY LABORATORY
MICROBIOLOGY LABORATORY
**Turnaround times establish a laboratory priority, subject to laboratory volume and are not guaranteed. Additional fees apply for afterhours, weekends and holidays.**
Laboratory Analysis Instructions
(Sample ID's must be unique)
Company: Air Quality Consulting, LLC Company: Air Quality Consulting, LLC
Address: 226 E 4800 S Address: 226 E 4800 S
Murray, UT 84107 Murray, UT 84107
Project Number and/or P.O. #: OCMB-81926 Project Zip Code:
Project Description/Location: Otter Creek Maintenance Building
Contact: Scott Bainbridge -1 PLM Rush *NO VERBALS* Phone: (385) 321-9701
Fax:
Cell: (385) 321-9701
Final Data Deliverable Email Address:
scott@aqc.solutions
PLM / PCM / TEM / NYS DTL RUSH PRIORITY STANDARD Air = A Bulk = B
Dust = D Food = F
Paint = P Soil = S
Dust RUSH PRIORITY STANDARD
*PRIOR NOTICE REQUIRED FOR SAME DAY TAT
Surface = SU Swab = SW
Tape = T Wipe = W
Metals RUSH PRIORITY STANDARD Drinking Water = DW
Waste Water = WW
Organics* SAME DAY RUSH PRIORITY STANDARD **ASTM E1792 approved wipe media only**
Viable Analysis** PRIORITY STANDARD
**TAT DEPENDENT ON SPEED OF MICROBIAL GROWTH
Medical Device Analysis RUSH STANDARD
Mold Analysis RUSH PRIORITY STANDARD
Special Instructions:
ASBESTOS CHEMISTRY MICROBIOLOGY ICO
1 OCMB-81926-1 X B 08/19/26 00:00
2 OCMB-81926-2 X B 08/19/26 00:00
3 OCMB-81926-3 X B 08/19/26 00:00
4 OCMB-81926-4 X B 08/19/26 00:00
5 OCMB-81926-5 X B 08/19/26 00:00
P L
M
P L
M S h o rt R ep o rt (E
PA
/6
/R
-9 3/
6)
T E
M
P C
M
N Y
S
D U
S T
M E
TA
L
S
O R
G A
N
IC
S
V
IA
B L
E S
M E
D
IC
A L
M O
L D
S am pl e
V ol um e
(L
A re a
S am pl e
Te m pe ra tu re
C
Le ng th (o r A liq uo ts
) x W id th
(o r A re a/
A liq uo t)
M at rix C od e of
C on ta in er s
D at e C ol le ct ed m m
/d d/ yy
T im e C ol le ct ed hh :m m
Eurofins Reservoirs Environmental, Inc establishes a unique Lab Sample ID, for each sample, by preceding each unique Client Sample ID with the laboratory RES Job Number.
Eurofins Reservoirs Environmental, Inc will analyze incoming samples based on information received and will not be responsible for errors or omissions in calculations resulting from the inaccuracy of original data. By signing, client/company representative agrees that submission of the following samples for requested analysis as indicated on this Chain of Custody shall consitute an analytical services agreement with payment terms of NET30. Failure to comply with payment terms may result in a 18% APR finance charge.
Relinquished By:
Scott Bainbridge Date/Time: 08/19/2026 11:54:08 Sample Condition: Acceptable
Received By:
Aubree Klausner Date/Time: 08/21/2026 11:50:42 Carrier: Fed-Ex
Eurofins Reservoirs Environmental, Inc Eurofins Reservoirs QA Manual
Effective July 28, 2026 Q:\QAQC\Eurofins Reservoirs QA Manual.pdf
(303) 964-1986 https://www.eurofinsus.com/builtenv https://clients.rei.et.eurofinsus.com
Lead Based Paint (LBP) Report Department of Facilities, Construction and Management
Otter Creek Maintenance Building 480 Hwy UT-22, Antimony, Utah 84712
August 21, 2026
LBP Inspector
Scott Bainbridge
PB-2648
Air Quality Consulting LLC
PBF-756
Scope of Work
Summary of Findings
We were hired by DFCM for an upcoming renovation to add a duct based HVAC system in the Otter Creek Maintenance Building. Samples were taken by Scott Bainbridge, using a SciAps X-550 XRF.
Lead Based Paint (LBP) is classified as 1.0 mg/cm² by weight by HUD. The results are included in this report.
No LBP was found in any surfaces to be disturbed by the renovation.
Refer to HUD, OSHA and EPA regulations regarding LBP of any amount regarding handling of LBP during renovation or demolition. TCLP testing may be needed if paint with lead content is in the waste stream.
Bold
Paint Samples
Description Sample Location Amount Substrate XRF Results
Homogeneous Area Condition
= Some lead content
LBP per HUD guidelines, >1.0 mg/cm²
Calibration 1.0
Calibration 1.0
Calibration 1.0
Tan Exterior East Exterior 6,400 SF Metal 0.0 Exterior Good
Tan Exterior South Exterior 6,400 SF Metal 0.0 Exterior Good
Tan Exterior West Exterior 6,400 SF Metal 0.0 Exterior Good
Tan Exterior North Exterior 6,400 SF Metal 0.0 Exterior Good
Tan Interior 1,200 SF Metal 0.0 Good
Tan Interior 1,200 SF Metal 0.0 Good
Tan Interior 1,200 SF Metal 0.0 Good
Tan Interior 1,200 SF Metal 0.0 Good
White Wall East Office Wall 450 SF Drywall 0.0 Good
Blue Wall 160 SF Drywall 0.0 Blue Interior Paint Good
Blue Wall 160 SF Drywall 0.0 Blue Interior Paint Good
Blue Wall 160 SF Drywall 0.0 Blue Interior Paint Good
White Wall 450 SF Drywall 0.0 Good
White Wall 450 SF Drywall 0.0 Good
White Wall 450 SF Drywall 0.0 Good
White Wall 450 SF Drywall 0.0 Good
Tan Structural East Roof Beam 550 SF Metal 0.0 Tan Structural Good
Tan Structural 550 SF Metal 0.0 Tan Structural Good
Tan Structural 550 SF Metal 0.0 Tan Structural Good
East Interior Wa Metal Interior Wall
South Interior W Metal Interior Wall
West Interior Wa Metal Interior Wall
North Interior W Metal Interior Wall
White Interior Pain
South Office Wal
West Office Wall
North Office Wal
East Bathroom W White Interior Pain
South Bathroom White Interior Pain
West Bathroom W White Interior Pain
North Bathroom White Interior Pain
South Roof Beam
West Roof Beam
| Otter Creek Maintenance Building Asbestos Report |
| 779712-1 |
| Otter Creek Maintenance Building LBP Report |
File details come from the government source that posted it. Updated .