Information_Technology_SOW__05-05-2015_(1).docx
DOCX document 24 KB Posted
- Attached to
- RLP Amendment No. 1
- Solicitation number
- 5UT0162
About this file
IT/Data Requirements
View the file
Other files
| File | Type | Posted |
|---|---|---|
| RLP.amend.1.docx | DOCX document | |
| 3516A_Simplified_clean_03272015.docx | DOCX document | |
| GSA_Form_3518A_clean_03272015.docx | DOCX document | |
| SimplifiedProposaltoLeaseSpaceForm1364A_server_room_changes_082214.docx | DOCX document | |
| RLP5.15.docx | DOCX document | |
| Security_Unit_Price_List_FSL_II__9-27-12(1).xlsx | XLSX spreadsheet | |
| Seismic.forms.pdf | ||
| SimplifiedLeaseProposalDataForm_1364A-1_rev-11_20_2012.docx | DOCX document | |
| USMS_Security_Office_SOW__05-05-2015.docx | DOCX document | |
| ASR.5.7.15.1.docx | DOCX document | |
| Facility_Security_Level_II___4-10-2013_entrance_edited.docx | DOCX document | |
| LUT147945.draft.issued.docx | DOCX document |
Show all 12
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Exhibit C
Information Technology
Information Outlets: All information outlets (IO) must be connected by horizontal cabling in a point-to-point home run (star topology) to the wiring centers. All cables identified as voice will be home-run back to the intermediate distribution frame (IDF) closet where public branch exchange (PBX) type dial tone emanates. All cables identified as data will be home-run back to the IDF.
All installed cabling, including cable pairs, connectors, patch cords, and patch panels, must be tested and certified to meet required performance specifications.
The IOs typically contain one or more Category 6a, four position (RJ-45 type) modular jacks. The specific quantity of IOs and the jacks per IO will be identified after the site survey has been completed.
The top left and/or top right jack/s will be used for voice; the balance will be designated for data and LAN purposes. Under no conditions will the cabling contractor tie wrap cable to the outside of existing conduit.
All cable must be installed via cable trays and any cable not in trays must be concealed and protected in a cable sheath.
Each network outlet flush mounted faceplate will incorporate four modular, universal RJ-45 IDC jack sockets meeting Category 6a specification: Black = voice, Ivory = data, Gray = LAN.
Each Employee Office will have a minimum of two IO outlets and the IO locations will be identified after the site survey has been completed.
The Work / Copy will have a minimum of two IO outlets and the IO locations will be identified after the site survey has been completed.
The Conference Room will have a minimum of seven IO outlets and the IO locations will be identified after the site survey has been completed. One IO jack will be located in the floor at the quadraplex electrical outlet, floor mounted with cover.
The Secure Storage will have a minimum of one IO outlet and the IO location will be identified after the site survey has been completed.
The Reception will have a minimum of one IO outlet and the IO location will be identified after the site survey has been completed.
General Requirements:
IT Room:
Provide one grounding bar to serve telecommunications equipment rack in the IT Room. (Example) Blackbox = RM066-R2 / Wallmount Buss Bar, 12" (15 Holes) - $160.60 (The buss bar to be grounded to building).
IT Room Continued:
Provide one distribution rack.
(Example) Blackbox = RM162A-R3 / 2-Post Premier Aluminum Distribution Rack, Black Finish, 84" (45U), 19"W - $245 each.
Provide one single-sided rack cable manager.
(Example) Blackbox = RM128 / Single-Sided Premier Cable Manager, 84", Black Finish, 3" Channel - $328 each.
Provide three patch panels.
(Example) Blackbox = JPM10G24-R2 / 10-Gigabit CAT6A Patch Panel, 19", 24-Port, 1.75"H, 1U - $499.95 each.
Provide 2” conduit run to IT Room from building telecommunications demarcation point.
Phone Lines and locations:
Provide one telephone line Employee Office for Secure STU III / STE / Viper capability.
Provide one additional telephone line per Employee Office for regular voice line.
Provide one dedicated fax line to be installed in the Work / Copy room.
Provide one telephone voice line in the Conference Room located in the floor at the quadraplex electrical outlet, floor mounted with cover.
Conference Room:
Provide two UN55H6203AFXZA – Samsung 55” LED TV (for Display / Video Presentations).
(Example) BestBuy = $799.99 each. Provide two HDMI cables for each (total of 4). All HDMI cables to connect to the Built-in wood base cabinet wall for AV equipment storage from TV. Final location will be identified after the site survey has been completed.
Provide one SBID8055i-SMP - SMART Board 55” Interactive LCD Display (for Touch Display / Touch Video Presentations).
(Example) Touch-Smartboards = $5,999.00 each. Provide one HDMI and one VGA cable. The HDMI and VGA cables are to connect to the Built-in wood base cabinet wall for AV equipment storage from SmartBoard. SmartBoard final location will be identified after the site survey has been completed.
Employee Offices:
Provide two UN40H6203AFXZA - Samsung - 40" LED TV (for Display / Video Presentations) (Example) BestBuy = $499.99 each. Provide two HDMI cables for each (total of 4) HDMI cables to connect to USMS desktop computer for PowerPoint presentations / Microsoft Lync session. Final location will be identified after the site survey has been completed.
*** The capabilities in Conference Room and the Employee Offices are to view local news, national news, weather and emergency channels. In addition, these monitors will be used for professional displays / video presentations. If cable capability is not available, satellite capability must be provided. Building prewiring of RG-6 coaxial cable and wall blocking will be needed at all monitor locations.***