ASR.5.7.15.1.docx

DOCX document 57 KB Posted

Attached to
RLP Amendment No. 1
Solicitation number
5UT0162
Issued by

About this file

Adency Special Requirements (ASRs)

View the file

Other files

File Type Posted
RLP.amend.1.docx DOCX document
3516A_Simplified_clean_03272015.docx DOCX document
GSA_Form_3518A_clean_03272015.docx DOCX document
SimplifiedProposaltoLeaseSpaceForm1364A_server_room_changes_082214.docx DOCX document
Information_Technology_SOW__05-05-2015_(1).docx DOCX document
RLP5.15.docx DOCX document
Security_Unit_Price_List_FSL_II__9-27-12(1).xlsx XLSX spreadsheet
Seismic.forms.pdf PDF
SimplifiedLeaseProposalDataForm_1364A-1_rev-11_20_2012.docx DOCX document
USMS_Security_Office_SOW__05-05-2015.docx DOCX document
Facility_Security_Level_II___4-10-2013_entrance_edited.docx DOCX document
LUT147945.draft.issued.docx DOCX document
Show all 12

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Attachment A

1.1
GARAGE
Square Footage:
2100 ABOA minimum sf
Quantity:
1
Flooring Structure:
N/A
Wall Systems:
Slab to slab
Ceiling Systems:
Exposed structural slab or metal deck height to accommodate 12’-0” H (minimum) door
Ceiling Height:
Height to accommodate 14’-0” H(minimum) doors
Doors:
2 separate14’0” H X 10’0” W (minimum) garage doors

Metal door w/metal frame between garage and office area Metal personnel door at rear (near garage doors)

Entry Control:
Scramble keypads at each garage door and exterior personnel door
Security:
Passive infrared motion detector
Acoustics:
N/A
Mechanical:
Ventilation minimum 4 air changes per hour

Carbon monoxide sensor with indicator light Exhaust fan

Plumbing:
Hose bib
Demising walls for entire space: (Separates tenant spaces and outside walls)
Slab-to-slab construction , or 9-gauge extruded steel mesh from floor to the top of the structural slab/roof above
1.2
GARAGE
Square Footage:
2100 ABOA sf
Quantity:
1

(continued from previous page)

Lighting:
Fluorescent 30-40 FTC

Emergency lighting Control /remote 3-way switches at each entrance to space/door

Power:
(5) duplex outlets

All junction boxes and back boxes recessed Conduit concealed in walls

Communication:
(1) combo voice/ data outlet

Interior Finishes:

Floors:
Sealed concrete with surface hardener
Base:
Integral cove
Walls:
GMU color options: light grey, blue, green, sand, beige
Ceiling:
Paint same as wall color if ceiling is enclosed
Millwork:
8-foot length of cabinets with laminated or stainless steel metal surface top along front wall
Miscellaneous:
Concrete filled bollards to protect scramble pads and intercoms at entry points and doors if needed.

No exterior windows permitted.

No garage door windows permitted.

No personnel door windows permitted.

Heating to 55 F; No cooling required.

2.1
OFFICE
Square Footage:
450 ABOA sf
Quantity:
3 @ 150 ABOA sf
Flooring Structure:
Standard floor loading
Wall Systems:
Ceiling high partitions

Reinforced wall blocking and television mounts in each office

Ceiling Systems:
Exposed spline w/ lay-in acoustic tiles
Ceiling Height:
9-foot minimum
Doors:
Solid core wood door
Entry Control:
Mortise lockset for each office

Hardware not on building keying system (off-master)

Security:
Passive infrared motion detector
Acoustics:
NC 35
Mechanical:
Building standard HVAC
Plumbing:
N/A
Lighting:
Parabolic, or combinations of adjustable energy efficient/user friendly lighting techniques and natural day-lighting capable of producing not less than30- 50FTC measured at desk height
Power: (each office)
(1) quadraplex outlet dedicated, color coded (red), “clean” for computers

(3) duplex outlets

(2) duplex outlets for TV

Communication:
(4) combo voice/ data outlet – 1 per wall

Interior Finishes:

Floors:
Carpet – 26 oz min w/integral pad or double glued pad
Base:
Hardwood
Walls:
Paint
Ceiling:
See above
Millwork:
N/A
Furniture/Equipment:
Agency provided
Miscellaneous:
Cable TV hook-up in each office

(2) reinforced wall blocking and television mounts (per office) Tamper-proof mailbox

3.1
CONFERENCE TRAINING ROOM
Square Footage:
575 ABOA sf
Quantity:
1
Flooring Structure:
Standard floor loading
Wall Systems:
Slab to slab sound conditioned
Ceiling Systems:
Exposed spline w/ lay-in acoustical tiles or gypsum board
Ceiling Height:
10-foot minimum (to accommodate ceiling mounted projection equipment hardware)
Doors:
Solid core wood door (s)
Entry Control:
Building standard lockset

Hardware not on building keying system (off-master)

Security:
N/A
Acoustics:
NC 40 STC 45
Mechanical:
Building standard HVAC; independent room control
Plumbing:
N/A
Lighting:
Parabolic, or combinations of adjustable energy efficient/user friendly lighting techniques and natural day-lighting capable of producing no fewer than 30-50 FTC measured at desk height

Switching or dimmer controls at front and rear

Power:
(8) duplex outlet dedicated, color coded (red), “clean” for computers

(8) duplex outlets

(1) duplex electrical outlet, floor mounted with cover

(1) duplex outlet dedicated in floor, color coded (red), “clean” for computers

(3) duplex outlets for TV and wall blocking needed

Communication:
(10) combo voice/ data outlets

(1) combo voice/data outlet in floor with cover Cable TV / MATV service In-ceiling mounted speaker system/minimum of 4 speakers

Interior Finishes:

Floors:
Carpet – 26 oz min w/integral pad or double glued pad
Base:
Hardwood
Walls:
Paint and/or wall covering
Ceiling:
See above
Millwork:
Built-in TV cabinet and wood bookshelves w/wood base cabinet below along one (1) wall for AV equipment storage

Door/panels to conceal/secure AV equipment – panels to prevent AV overheating

Furniture/Equipment:
Whiteboards - Large

Miscellaneous:

(3) Reinforced wall blocking

(2) Television mounts

(2) Cable TV hook-up

4.1
COMPUTER ROOM/TELEPHONE ROOM

Storage

Square Footage:
90 ABOA sf
Quantity:
1
Flooring Structure:
Standard floor loading
Wall Systems:
Slab to slab sound conditioned partition
Ceiling Systems:
Exposed spline w/ lay-in acoustical tiles
Ceiling Height:
9-foot minimum
Doors:
Solid core wood door

Door closer /position switch and magnetic contact

Entry Control:
Mortise lockset

Hardware not on building keying system (off master) Scramble pad Door closer / position switch and magnetic contact

Security:
N/A
Acoustics:
NC 40 STC 45
Mechanical:
HVAC separate controls

24/7 operation Temperature control required between 64- 68 degrees F

Plumbing:
N/A
Lighting:
Indirect fluorescent 50 FTC

Emergency lighting

Power:
(2) quadraplex computer/data outlets dedicated, color coded

(4) duplex electrical outlets, dedicated Emergency power – UPS 30 min, or code minimum

Communication:
N/A

Interior Finishes:

Floors:
VCT
Base:
Resilient Vinyl
Walls:
Paint
Ceiling:
N/A
Millwork:
(1) 4’ x 8’ plywood mounting board fastened to walls
Furniture/Equipment:
N/A
Miscellaneous:
No exterior windows permitted

Solid construction ceiling

5.1
WORK/SUPPLY/MAIL/FILE ROOM/STORAGE

Office

Square Footage:
150 ABOA sf
Quantity:
1
Flooring Structure:
Normal floor-loading
Wall Systems:
Ceiling high partitions
Ceiling Systems:
Exposed spline w/ lay-in acoustical tiles
Ceiling Height:
9-foot minimum
Doors:
Solid core wood door
Entry Control:
Mortise lockset

Hardware not on building keying system (off master)

Security:
N/A
Acoustics:
NC 35
Mechanical:
Building standard HVAC unless equip heat load determines otherwise
Plumbing:
N/A
Lighting:
Building standard fluorescent 50-60 FTC
Power:
(3) duplex outlets

(2) duplex outlet dedicated, color coded (red), “clean” for printers Clock outlet (power only) over door

Communication:
(3) combo voice/ data outlet

Wall telephone outlet Fax line service

Interior Finishes:

Floors:
VCT
Base:
Resilient Vinyl
Walls:
Paint
Ceiling:
N/A
Millwork:
Built-in adjustable shelving 12”D x 84Z” H – minimum (2) walls

Base cabinets 24”D and upper cabinets 12”D with adjustable shelves, plastic laminate clad installed on (1) wall

Furniture/Equipment:
Fax machine, Copier , (2) Printers, Shredder (agency furnished, list provided in attachments)
6.1
SECURE STORAGE ROOM

Operations

Square Footage:
275 ABOA sf
Quantity:
1
Flooring Structure:
Standard floor loading
Wall Systems:
Slab to slab, security (9-gauge extruded steel mesh between layers of drywall)
Ceiling Systems:
Finished ceiling with 9-gauge extruded steel mesh
Ceiling Height:
9-foot minimum

10-foot maximum

Doors:
Hollow metal door / metal frame

Expanded metal day gate/locking device

Entry Control:
Door closer /position switch and magnetic contact

Electric door strike Scramble keypad Door release activator Hardware not on building keying system

Security:
Passive infrared motion detector and heat and smoke sensors
Acoustics:
N/A
Mechanical:
Building standard HVAC

1” PVC pipe through walls w/elbow at top and bottom for ventilation

Lighting:
Building standard fluorescent 50-60 FTC

Emergency lighting

Power:
(8) Duplex electrical outlets

(1) Combo voice/ data outlet

Communication:
Wall telephone outlet

Interior Finishes:

Floors:
VCT
Base:
Resilient Vinyl
Walls:
Paint
Ceiling:
N/A
Millwork:
Adjustable metal shelving installed along two walls
Miscellaneous:
No exterior windows permitted
7.1
BREAK ROOM
Square Footage:
200 ABOA sf
Quantity:
1
Flooring Structure:
Standard floor loading
Wall Systems:
Ceiling high partitions
Ceiling Systems:
Exposed spline w/ lay-in acoustical tiles
Ceiling Height:
9-foot minimum
Doors:
Solid core wood door
Entry Control:
Building standard lockset

Hardware not on building keying system (off master)

Security:
N/A
Acoustics:
N/A
Mechanical:
Building standard HVAC
Plumbing:
Double bowl sink

Piping for refrigerator ice maker (refrigerator supplied by Government)

Lighting:
Combinations of adjustable energy efficient/user friendly lighting techniques and natural day-lighting capable of producing no less than 30-50 FTC measured at desk height
Power:
(4) duplex outlets

(4) GFI duplex outlets at counter height Power for refrigerator and microwave (with vent)[microwave supplied by Government]) Power for garbage disposal (future use) Clock outlet (power only) over door

Communication:
(1) Combo voice/ data outlet

Interior Finishes:

Floors:
Sealed tile or terrazzo
Base:
Resilient Vinyl
Walls:
Paint
Ceiling:
N/A
Millwork:
Base cabinets 24”D and upper cabinets 12”D with adjustable shelves, plastic laminate clad with plastic laminate clad countertop and back splash. Length to be determined at layout.
Furniture/Equipment:
Refrigerator and Microwave (Government agency furnished)
8.1
PERSONNEL RESTROOMS (1 MALE, 1 FEMALE)
Square Footage:
180 ABOA sf total
Quantity:
2 @ 90 ABOA sf each
Power:
(1) Duplex outlet

(1) GFI duplex outlet at 42” at cabinet/sink area

(1) GFI duplex outlet

Communication:
N/A
Interior Finishes:
Paint
Floors:
Epoxy terrazzo, 3/8” or sealed tile
Base:
Integral cove
Walls:
GMU color options: light grey, blue, green, sand, beige

Wainscoting to 48-inches

Ceiling:
9-foot minimum

Paint to wall color if gypsum

Millwork:
Base (24”D x 36”H) and upper cabinets (12”D x 24”H), with laminate clad countertop.
Equipment:
Coat hook

Paper towel dispenser/disposal Soap dispenser Toilet paper dispenser Mirror above sink

Miscellaneous:
No exterior windows permitted

A minimum of 10 air exchanges per hour

Initials: ______ & ______
Govm’t Lessor

File details come from the government source that posted it. Updated .