| Square Footage: |
| 2100 ABOA minimum sf |
| Wall Systems: |
| Slab to slab |
| Ceiling Systems: |
| Exposed structural slab or metal deck height to accommodate 12’-0” H (minimum) door |
| Ceiling Height: |
| Height to accommodate 14’-0” H(minimum) doors |
| Doors: |
| 2 separate14’0” H X 10’0” W (minimum) garage doors |
Metal door w/metal frame between garage and office area Metal personnel door at rear (near garage doors)
| Entry Control: |
| Scramble keypads at each garage door and exterior personnel door |
| Security: |
| Passive infrared motion detector |
| Mechanical: |
| Ventilation minimum 4 air changes per hour |
Carbon monoxide sensor with indicator light Exhaust fan
| Demising walls for entire space: (Separates tenant spaces and outside walls) |
| Slab-to-slab construction , or 9-gauge extruded steel mesh from floor to the top of the structural slab/roof above |
| Square Footage: |
| 2100 ABOA sf |
(continued from previous page)
| Lighting: |
| Fluorescent 30-40 FTC |
Emergency lighting Control /remote 3-way switches at each entrance to space/door
| Power: |
| (5) duplex outlets |
All junction boxes and back boxes recessed Conduit concealed in walls
| Communication: |
| (1) combo voice/ data outlet |
Interior Finishes:
| Floors: |
| Sealed concrete with surface hardener |
| Walls: |
| GMU color options: light grey, blue, green, sand, beige |
| Ceiling: |
| Paint same as wall color if ceiling is enclosed |
| Millwork: |
| 8-foot length of cabinets with laminated or stainless steel metal surface top along front wall |
| Miscellaneous: |
| Concrete filled bollards to protect scramble pads and intercoms at entry points and doors if needed. |
No exterior windows permitted.
No garage door windows permitted.
No personnel door windows permitted.
Heating to 55 F; No cooling required.
| Square Footage: |
| 450 ABOA sf |
| Quantity: |
| 3 @ 150 ABOA sf |
| Flooring Structure: |
| Standard floor loading |
| Wall Systems: |
| Ceiling high partitions |
Reinforced wall blocking and television mounts in each office
| Ceiling Systems: |
| Exposed spline w/ lay-in acoustic tiles |
| Ceiling Height: |
| 9-foot minimum |
| Doors: |
| Solid core wood door |
| Entry Control: |
| Mortise lockset for each office |
Hardware not on building keying system (off-master)
| Security: |
| Passive infrared motion detector |
| Mechanical: |
| Building standard HVAC |
| Lighting: |
| Parabolic, or combinations of adjustable energy efficient/user friendly lighting techniques and natural day-lighting capable of producing not less than30- 50FTC measured at desk height |
| Power: (each office) |
| (1) quadraplex outlet dedicated, color coded (red), “clean” for computers |
(3) duplex outlets
(2) duplex outlets for TV
| Communication: |
| (4) combo voice/ data outlet – 1 per wall |
Interior Finishes:
| Floors: |
| Carpet – 26 oz min w/integral pad or double glued pad |
| Furniture/Equipment: |
| Agency provided |
| Miscellaneous: |
| Cable TV hook-up in each office |
(2) reinforced wall blocking and television mounts (per office) Tamper-proof mailbox
| 3.1 |
| CONFERENCE TRAINING ROOM |
| Square Footage: |
| 575 ABOA sf |
| Flooring Structure: |
| Standard floor loading |
| Wall Systems: |
| Slab to slab sound conditioned |
| Ceiling Systems: |
| Exposed spline w/ lay-in acoustical tiles or gypsum board |
| Ceiling Height: |
| 10-foot minimum (to accommodate ceiling mounted projection equipment hardware) |
| Doors: |
| Solid core wood door (s) |
| Entry Control: |
| Building standard lockset |
Hardware not on building keying system (off-master)
| Mechanical: |
| Building standard HVAC; independent room control |
| Lighting: |
| Parabolic, or combinations of adjustable energy efficient/user friendly lighting techniques and natural day-lighting capable of producing no fewer than 30-50 FTC measured at desk height |
Switching or dimmer controls at front and rear
| Power: |
| (8) duplex outlet dedicated, color coded (red), “clean” for computers |
(8) duplex outlets
(1) duplex electrical outlet, floor mounted with cover
(1) duplex outlet dedicated in floor, color coded (red), “clean” for computers
(3) duplex outlets for TV and wall blocking needed
| Communication: |
| (10) combo voice/ data outlets |
(1) combo voice/data outlet in floor with cover Cable TV / MATV service In-ceiling mounted speaker system/minimum of 4 speakers
Interior Finishes:
| Floors: |
| Carpet – 26 oz min w/integral pad or double glued pad |
| Walls: |
| Paint and/or wall covering |
| Millwork: |
| Built-in TV cabinet and wood bookshelves w/wood base cabinet below along one (1) wall for AV equipment storage |
Door/panels to conceal/secure AV equipment – panels to prevent AV overheating
| Furniture/Equipment: |
| Whiteboards - Large |
Miscellaneous:
(3) Reinforced wall blocking
(2) Television mounts
(2) Cable TV hook-up
| 4.1 |
| COMPUTER ROOM/TELEPHONE ROOM |
Storage
| Square Footage: |
| 90 ABOA sf |
| Flooring Structure: |
| Standard floor loading |
| Wall Systems: |
| Slab to slab sound conditioned partition |
| Ceiling Systems: |
| Exposed spline w/ lay-in acoustical tiles |
| Ceiling Height: |
| 9-foot minimum |
| Doors: |
| Solid core wood door |
Door closer /position switch and magnetic contact
| Entry Control: |
| Mortise lockset |
Hardware not on building keying system (off master) Scramble pad Door closer / position switch and magnetic contact
| Mechanical: |
| HVAC separate controls |
24/7 operation Temperature control required between 64- 68 degrees F
| Lighting: |
| Indirect fluorescent 50 FTC |
Emergency lighting
| Power: |
| (2) quadraplex computer/data outlets dedicated, color coded |
(4) duplex electrical outlets, dedicated Emergency power – UPS 30 min, or code minimum
Interior Finishes:
| Millwork: |
| (1) 4’ x 8’ plywood mounting board fastened to walls |
| Miscellaneous: |
| No exterior windows permitted |
Solid construction ceiling
| 5.1 |
| WORK/SUPPLY/MAIL/FILE ROOM/STORAGE |
Office
| Square Footage: |
| 150 ABOA sf |
| Flooring Structure: |
| Normal floor-loading |
| Wall Systems: |
| Ceiling high partitions |
| Ceiling Systems: |
| Exposed spline w/ lay-in acoustical tiles |
| Ceiling Height: |
| 9-foot minimum |
| Doors: |
| Solid core wood door |
| Entry Control: |
| Mortise lockset |
Hardware not on building keying system (off master)
| Mechanical: |
| Building standard HVAC unless equip heat load determines otherwise |
| Lighting: |
| Building standard fluorescent 50-60 FTC |
| Power: |
| (3) duplex outlets |
(2) duplex outlet dedicated, color coded (red), “clean” for printers Clock outlet (power only) over door
| Communication: |
| (3) combo voice/ data outlet |
Wall telephone outlet Fax line service
Interior Finishes:
| Millwork: |
| Built-in adjustable shelving 12”D x 84Z” H – minimum (2) walls |
Base cabinets 24”D and upper cabinets 12”D with adjustable shelves, plastic laminate clad installed on (1) wall
| Furniture/Equipment: |
| Fax machine, Copier , (2) Printers, Shredder (agency furnished, list provided in attachments) |
Operations
| Square Footage: |
| 275 ABOA sf |
| Flooring Structure: |
| Standard floor loading |
| Wall Systems: |
| Slab to slab, security (9-gauge extruded steel mesh between layers of drywall) |
| Ceiling Systems: |
| Finished ceiling with 9-gauge extruded steel mesh |
| Ceiling Height: |
| 9-foot minimum |
10-foot maximum
| Doors: |
| Hollow metal door / metal frame |
Expanded metal day gate/locking device
| Entry Control: |
| Door closer /position switch and magnetic contact |
Electric door strike Scramble keypad Door release activator Hardware not on building keying system
| Security: |
| Passive infrared motion detector and heat and smoke sensors |
| Mechanical: |
| Building standard HVAC |
1” PVC pipe through walls w/elbow at top and bottom for ventilation
| Lighting: |
| Building standard fluorescent 50-60 FTC |
Emergency lighting
| Power: |
| (8) Duplex electrical outlets |
(1) Combo voice/ data outlet
| Communication: |
| Wall telephone outlet |
Interior Finishes:
| Millwork: |
| Adjustable metal shelving installed along two walls |
| Miscellaneous: |
| No exterior windows permitted |
| Square Footage: |
| 200 ABOA sf |
| Flooring Structure: |
| Standard floor loading |
| Wall Systems: |
| Ceiling high partitions |
| Ceiling Systems: |
| Exposed spline w/ lay-in acoustical tiles |
| Ceiling Height: |
| 9-foot minimum |
| Doors: |
| Solid core wood door |
| Entry Control: |
| Building standard lockset |
Hardware not on building keying system (off master)
| Mechanical: |
| Building standard HVAC |
| Plumbing: |
| Double bowl sink |
Piping for refrigerator ice maker (refrigerator supplied by Government)
| Lighting: |
| Combinations of adjustable energy efficient/user friendly lighting techniques and natural day-lighting capable of producing no less than 30-50 FTC measured at desk height |
| Power: |
| (4) duplex outlets |
(4) GFI duplex outlets at counter height Power for refrigerator and microwave (with vent)[microwave supplied by Government]) Power for garbage disposal (future use) Clock outlet (power only) over door
| Communication: |
| (1) Combo voice/ data outlet |
Interior Finishes:
| Floors: |
| Sealed tile or terrazzo |
| Millwork: |
| Base cabinets 24”D and upper cabinets 12”D with adjustable shelves, plastic laminate clad with plastic laminate clad countertop and back splash. Length to be determined at layout. |
| Furniture/Equipment: |
| Refrigerator and Microwave (Government agency furnished) |
| 8.1 |
| PERSONNEL RESTROOMS (1 MALE, 1 FEMALE) |
| Square Footage: |
| 180 ABOA sf total |
| Quantity: |
| 2 @ 90 ABOA sf each |
(1) GFI duplex outlet at 42” at cabinet/sink area
(1) GFI duplex outlet
| Floors: |
| Epoxy terrazzo, 3/8” or sealed tile |
| Walls: |
| GMU color options: light grey, blue, green, sand, beige |
Wainscoting to 48-inches
Paint to wall color if gypsum
| Millwork: |
| Base (24”D x 36”H) and upper cabinets (12”D x 24”H), with laminate clad countertop. |
Paper towel dispenser/disposal Soap dispenser Toilet paper dispenser Mirror above sink
| Miscellaneous: |
| No exterior windows permitted |
A minimum of 10 air exchanges per hour
| Initials: ______ & ______ |
| Govm’t Lessor | |