589A7-23-305 Bid Dwgs SET 7 of 7.pdf

PDF 6 MB Posted

Attached to
Z2DA--589A7-23-305, Prepare Site for Choice Dining Equipment FY27 NRM
Solicitation number
36C25526R0160
Issued by

About this file

This is a Construction Documents package for a federal healthcare facility project titled "Prepare Site for Choice Dining Equipment" at a VA medical center in Wichita, Kansas (Project 589A7-23-305). The project involves demolition and renovation of dining facility spaces on the first floor, totaling approximately 5,500 square feet of kitchen and dining areas.

The scope encompasses comprehensive site preparation work including removal of existing interior partitions, ceilings, floor finishes, doors, windows, equipment, and MEP systems; installation of new architectural components such as metal stud and gypsum wallboard partitions, doors and frames, finish materials, and casework; and integration of new mechanical (HVAC ductwork, fan-powered VAV terminal units, domestic hot water heating), plumbing (domestic water, drainage, gas connections), electrical (lighting, power receptacles, fire alarm, data systems), and fire suppression systems. The construction documents include detailed architectural general notes and demolition keynotes requiring contractor coordination with VA Contracting Officer's Representative, field verification of existing conditions, protection of elements to remain, sequencing to maintain hospital operations, waste removal to approved dumpster locations, and careful handling of salvageable materials. Temporary fire-rated construction barriers, dust partitions, and access mats are required during construction in occupied spaces, with restoration to serviceable condition before work completion. The project specifies performance standards for wall and ceiling patching, surface finishes, equipment connections, and compliance with VA construction standards, fire ratings, and accessibility requirements.

View the file

Other files

Show all 18

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

DEMOLITION PLAN LEGEND

FULL HEIGHT ONE-HOUR FIRE RATED TEMPORARY

PARTITION

ELEMENT TO BE REMOVED, TYPICAL

EXISTING CONSTRUCTION TO REMAIN UNO.

INDICATES AREA TO BE REMOVED, TYPICAL

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMP

321 4 5 6 7 8 9 10

Alesia Architecture P.C.

3705 North 200th Street Elkhorn, Nebraska 68022 Phone: (402) 291-6941 o n e e ig h th i n c h o n e f o o t th re e i n c h e s o n e f o o t o n e a n d o n e h a lf i n c h e s o n e f o o t o n e i n c h o n e f o o t th re e q u a rt e rs i n c h o n e f o o t o n e h a lf i n c h o n e f o o t th re e e ig h th s i n c h o n e f o o t o n e q u a rt e r in c h o n e f o o t

CONSTRUCTION

DOCUMENTS

PREPARE SITE FOR CHOICE

DINING EQUIPMENT

589A7-23-305

5500 E KELLOGG AVE, WICHITA, KS

A

B

C

D

E

F

A u to d e s k D o c s /1

A -2

-3

P re p a re

S it e f o r C h o ic e

D in in g /5

A -2

-3

.B

.A rc h

R

-E x is ti n g

.r v t

/2

/2

:4

:1

P

M

A-001

ARCHITECTURAL GENERAL NOTES

AND KEYNOTES

RJO JJG05/17/2024

DEMOLITION GENERAL NOTES

1 REFER TO PROJECT SPECIFICATIONS FOR OTHER APPLICABLE INFORMATION.

2 REFER TO MEP DRAWINGS FOR INFORMATION PERTAINING TO MECHANICAL, ELECTRICAL, AND PLUMBING WORK. ALL NOTES REGARDING THE REMOVAL, INSTALL, LOCATION, AND/OR INFORMATION OF MEP ITEMS ARE

GIVEN FOR REFERENCE AND CLARITY ONLY.

3 DEMOLITION AND CONSTRUCTION MUST BE SEQUENCED AND COORDINATED TO INSURE THE HOSPITAL’S OPERATIONS ARE CONTINUALLY MAINTAINED.

4 DEMOLITION PLAN REFLECTS INFORMATION GATHERED FROM EXISTING DRAWINGS AND FIELD INSPECTIONS. EACH CONTRACTOR SHALL VERIFY ACCURACY OF INFORMATION AND INCLUDE ALL REQUIRED DEMOLITION

WORK IN BID. CONTRACTOR SHALL REPORT ANY DISCREPANCIES TO THE COR.

5 CONTACT COR FOR DISCREPANCIES FOR DIRECTION IF DEMOLISHED WALLS CONTAIN UNANTICIPATED PIPING, ELECTRICAL, OR STRUCTURAL ELEMENTS.

6 ALL LOCATIONS INDICATED ARE APPROXIMATE AND MUST BE FIELD VERIFIED. ANY DISCREPANCIES MUST BE REPORTED TO THE COR BEFORE CONTINUATION OF THE WORK.

7 EXISTING ELEMENTS TO BE DEMOLISHED ARE SHOWN AS DARK DASHED LINES ON DEMOLITION PLANS. EXISTING ELEMENTS TO REMAIN ARE SHOWN AS SOLID GREY LINES.

8 PRIOR TO DISPOSING OF ANY ITEMS SEE COR. CONTRACTOR IS TO VALIDATE WITH COR WHAT IS TO BE SALVAGED BEFORE DEMOLITION PROCESS STARTS. AS WELL AS WHERE AND HOW SALVAGED MATERIAL SHALL BE STORED. CONTRACTOR IS RESPONSIBLE FOR ANY EXTRA COSTS THAT INCUR DUE TO NEGLIGENCE AND/OR LACK OF THOROUGHNESS.

9 PATCH AND/OR REPAIR ALL EXISTING WALL SURFACES TO MATCH ADJACENT EXISTING TO REMAIN SURFACES. PREP, PRIME, AND PAINT THE ENTIER WALL AT REPAIRED LOCATION.

10 SALVAGE AND RETURN TO VA ITEMS IDENTIFIED BY THE COR FOR FUTURE USE NOT OTHERWISE DESIGNATED BY THESE DRAWINGS.

11 VA TO REMOVE EXISTING FURNISHINGS AND MOBILE LIGHT WEIGHT EQUIPMENT PRIOR TO START OF WORK BY GENERAL CONTRACTOR.

12 REMOVE EXISTING FINISHES TO PLASTER, CONCRETE, CLAY TILE OR MASONRY SUBSTRATE U.N.O.

13 REFER TO TECHNOLOGY DRAWINGS FOR INFORMATION PERTAINING TO TECHNOLOGY DEMOLITION AND RENOVATION.

14 EXISTING FIRE PROTECTION SYSTEM TO REMAIN OPERATIONAL DURING CONSTRUCTION UNLESS OTHERWISE ARRANGED WITH THE COR.

15 CONSTRUCTION WASTE IS TO BE REMOVED TO DUMPSTER. THE COR WILL APPROVE OF DUMPSTER LOCATIONS

16 DISRUPTIVE ACTIVITIES IN OCCUPIED SPACES TO BE LIMITED AS DIRECTED BY COR. COORDINATE WELL IN ADVANCE WITH COR PRIOR TO BEGINNING WORK.

17 IN AREAS THAT ARE TO BE OCCUPIED AND/OR OPERATIONAL DURING THE CONSTRUCTION PERIOD AND DESIGNATED FOR AFTER-HOURS AND/OR WEEKEND WORK, THE CONTRACTOR SHALL RETURN AREA TO SERVICEABLE CONDITION PRIOR TO THE END OF THE CONTRACTOR’S WORK PERIOD INCLUDING CLEANING OF AREA AND REINSTALLATION OF ACOUSTICAL TILE CEILINGS.

18 RETAIN ALL STRUCTURAL COLUMNS, PROTECT FROM DAMAGE.

19 ONLY REMOVE PORTIONS OF CEILING NEEDED TO COMPLETE WORK. PATCH AND REPAIR AS NEEDED FOR NEW CONSTRUCTION. MATCH ADJACENT FINISHES U.N.O.

20 SEE REFLECTED CEILING PLANS FOR EXTENTS OF CEILING TO BE REMOVED AND REPLACED.

21 TEMPORARY CONSTRUCTION BARRIER WALLS & MATS ARE TO BE REMOVED AFTER COMPLETION OF WORK. PATCH & REPAIR ANY DAMAGE TO EXISTING FINISHES.

22 PROTECT ALL EXISTING ELEMENTS TO REMAIN. ANY DAMAGE TO EXISTING ELEMENTS TO REMAIN DURING CONSTRUCTION SHALL BE PAID FOR BY THE CONTRACTOR.

23 REPAIR EXISTING FLOOR SUBSTRATES WITH SELF-LEVELING FILLER AS NEEDED FOR NEW CONSTRUCTION.

24 COORDINATE THE REMOVAL AND RELOCATIONS OF EXISTING FIRE CABINETS WITHIN PROJECT AREA W/ VA COR.

RENOVATION GENERAL NOTES

1 REFER TO ARCHITECTURAL DEMO PLANS FOR EXTENTS OF DEMOLITION WORK IN PROJECT AREA.

2 REFER TO ROOM FINISH SCHEDULE FOR FINISHES.

3 REFER TO MEP DRAWINGS FOR INFORMATION PERTAINING TO MECHANICAL, ELECTRICAL, AND PLUMBING WORK. ALL NOTES REGARDING THE REMOVAL, INSTALL, LOCATION AND/OR INFORMATION OF MEP ITEMS ARE

GIVEN FOR REFERENCE AND CLARITY ONLY.

5 REFER TO FIRE PROTECTION DWGS FOR RELATED FIRE PROTECTION REMODELING.

6 PATCH EXISTING OPENINGS AS NEEDED AND PREP SURFACE FOR NEW FINISH.

7 PATCH EXISTING WALL W/ FINISHES TO MATCH EXISTING WHERE DAMAGED BY DEMOLITION.

8 COORDINATE ALL REINSTALLATION OF VA ITEMS & ACCESSORIES WITH COR.

9 CONSTRUCTION WASTE IS TO BE REMOVED TO DUMPSTER. THE COR WILL APPROVE OF DUMPSTER LOCATIONS.

10 INFILL ALL LOCATIONS WHERE MASONRY WALLS HAVE BEEN REMOVED.

11 ALL WALLS AND CHASES TO BE INSULATED - SEE WALL TYPES AND ARCHITECTURAL GENERAL NOTES.

12 CONTRACTOR TO VERIFY LOCATION OF EXISTING MEP AND RELATED ITEMS PRIOR TO START OF RENOVATION WORK.COORDINATE ALL EXISTING AND NEW

13 MECHANICAL AND ELECTRICAL WORK TO FIT WITHIN WALLS AND CHASES SHOWN; WHERE EXISTING OR NEW MECHANICAL AND ELECTRICAL WORK FALLS OUTSIDE OF THE PROVIDED WALLS AND CHASES, THE CONTRACTOR SHALL NOTIFY THE COR FOR REVISIONS TO THE LAYOUT OF WALLS OR CHASE AT NO ADDITIONAL COST TO THE OWNER.

14 DEMO WORK AND NEW WORK INDICATE APPROXIMATE AREA TO BE REMOVED. CONTRACTOR TO FIELD VERIFY ACTUAL AREA TO BE REMOVED. CONTRACTOR TO COORDINATE WORK AREA WITH ALL TRADES FOR FULL

SCOPE OF WORK. CONTRACTOR IS RESPONSIBLE FOR WORK AS NECESSARY, FIELD VERIFY.

15 MAINTAIN ALL EXISTING FIRE RATINGS. FIELD VERIFY.

16 REMOVE AND REINSTALL ALL ITEMS LOCATED IN CEILING (LIGHTS, DIFFUSERS, SPRINKLER HEADS, EXIT SIGNS, SIGNS, FANS, AHU, ALARMS, ANTENNAS, OCCUPANCY SENSORS, SPEAKERS, NURSE CALL, CODE LIGHTS, EMERGENCY SHOWER, CAMERA, CURTAIN TRACK, PATIENT LIFT OR ACCESS HATCHES, ETC.) AS REQUIRED. NEW CEILING TILES THAT ARE INSTALLED SHALL HAVE TAMPER PROOF CLIPS U.N.O. ALL ITEMS MAY NOT BE

INDICATED ON DRAWINGS. FIELD VERIFY FOR FULL SCOPE OF WORK.

17 ANY CONTRACTOR DISTURBED FINISHES MUST BE RESTORED TO MATCH THE EXISTING FINISH. COORDINATE WITH VA TO MATCH EXISTING FINISHES.

18 COVER AND PROTECT ALL VA EQUIPMENT AND FURNITURE SO THAT THE FUNCTION AND APPEARANCE IS NOT AFFECTED BY CONSTRUCTION, THE CONTRACTOR, THEIR EQUIPMENT AND MATERIALS, OR ANY INVOLVED

ACTIONS.

19 A 1 HR MINIMUM FIRE-RATED SEPARATION IS REQUIRED BETWEEN ALL OCCUPIED SPACE AND CONSTRUCTION AREAS. THIS PROTECTION INCLUDES ANY EXISTING PENETRATIONS AND OPENINGS.

20 PATCH FLOOR SLABS AT PENETRATIONS AND OPENINGS RESULTING FROM REMOVAL OF PIPING AS NECESSARY TO MAINTAIN EXISTING FIRE SEPARATION AND FINISH AT PIPING AND EQUIPMENT REMOVAL LOCATIONS

PATCH TO MATCH ADJACENT EXISTING FLOOR.

21 PATCH PARTITION WALLS AT NEW PENETRATIONS RESULTING FROM INSTALLATION OF NEW PIPING. SEAL AGAINST NEW PIPING TO MATCH EXISTING WALL CONDITION. MATCH EXISTING WALL CONDITION (FINISH, PAINT COLOR, WALL MOUNTED EQUIPMENT AND ACCESSORIES, ETC.) TYP. WALL CONDITION: GWB OR PLASTER. SEE MEP DRAWINGS FOR FULL EXTENT OF WORK. REMOVE REPLACE, PATCH AND REPAIR WALL TO THE EXTENT NECESSARY TO COMPLETE WORK AND MEET THE REQUIRED STANDARDS FOR VA CONSTRUCTION. COORDINATE REMOVAL AND REINSTALLATION OF WALL MOUNTED EQUIPMENT, ETC. FIELD VERIFY. MAINTAIN EXISTING FIRE RATINGS. VERIFY EXISTING CONDITIONS WITH COR DURING PRE-CONSTRUCTION WALK THRU, ADDITIONAL COSTS WILL NOT BE ALLOWED.

22 PATCH PARTITION WALLS AND FILL/PATCH OPENINGS RESULTING FROM REMOVAL OF PIPING. MATCH EXISTING WALL CONDITION (FINISH, PAINT COLOR, WALL MOUNTED EQUIPMENT, AND ACCESSORIES, ETC.) TYP.

WALL CONDITION: GWB OR PLASTER. SEE MEP DRAWINGS FOR FULL EXTENT OF WORK. REMOVE, REPLACE, PATCH, AND REPAIR WALL TO THE EXTENT NECESSARY TO COMPLETE WORK AND MEET THE REQUIRED STANDARDS FOR VA CONTSTRUCTION. COORDINATE REMOVAL AND REINSTALLATION OF WALL MOUNTED EQUIPMENT, ETC. FIELD VERIFY. MAINTAIN EXISTING FIRE RATINGS. VERIFY EXISTING CONDITIONS WITH COR

DURING PRE-CONSTRUCTION WALK THRU, ADDITIONAL COSTS WILL NOT BE ALLOWED.

25 CONTRACTOR SHALL PROVIDE ALL NECESSARY TEMPORARY SUPPORTS AS REQUIRED FOR CEILING MOUNTED EQUIPMENT DURING DEMOLITION AND REBUILD OPERATIONS.

26 REMOVE TEMPORARY CONSTRUCTION PARTITIONS AFTER COMPLETION OF WORK. PATCH/PAINT TO MATCH EXISTING/NEW FINISHES.

27 DISRUPTIVE ACTIVITIES IN OCCUPIED SPACES TO BE LIMITED AS DIRECTED BY COR. COORDINATE WELL IN ADVANCE WITH COR PRIOR TO BEGINNING WORK.DEMOLITION KEYNOTES 1 TEMPORARY 1-HR RATED CONSTRUCTION DUST PARTITION W/ 3'-0" X 7'-0" 1-HR RATED DOOR AND HM FRAME.

2 STICKY WALK-OFF MAT AT CONSTRUCTION ENTRANCES.

3 EXISTING KITCHEN EQUIPMENT TO BE REMOVED. COORDINATE WITH VA COR.

4 REMOVE EXISTING LOCKERS.

5 WALL TO BE REMOVED IN ITS ENTIRETY.

6 DOOR TO BE REMOVED.

7 DOOR AND FRAME TO BE REMOVED.

8 CASEWORK TO BE REMOVED.

9 REMOVE EXISTING WALL FINISHES AND FURRING.

10 REMOVE EXISTING WALL FINISH TO WALL FRAMING THIS SIDE ONLY & PREP FOR NEW FINISHES.

11 REMOVE EXISTING WALL FINISHES TO WALL FRAMING ON BOTH SIDES & PREP FOR NEW FINISHES.

12 WINDOW AND FRAME TO BE REMOVED.

13 REMOVE EXISTING PLUMBING FIXTURE. REFER TO MEP.REMOVE EXISTING FLOOR FINISH TO BARE CONCRETE IN THIS AREA & PREP FOR NEW FLOOR FINISHES.

COORDINATE EXTENTS WITH VA COR.

14 REMOVE EXISTING EQUIPMENT POSTS AND RAIL.

15 REMOVE EXISTING CEILING AND ASSOCIATED FRAMING. COORDINATE EXTENTS WITH NEW CONSTRUCTION.

16 REMOVE EXISTING HOOD VENT. REFER TO MEP.

17 REMOVE EXISTING CEILING AND ASSOCIATED MATERIALS.

18 REMOVE ELECTRICAL FIXTURES. REFER TO MEP.

Mark Revisions: Date:

A

R C H I T E

C

T

S T A T E

O F N E B

R A S K A

05/17/2024

RICHARD

JOSEPH

ONKEN

A-5125

NOTE:

ALL PARTITION TYPES INDICATED,

MAY-NOT BE USED. REFER TO

PLANS FOR MORE INFORMATION.

TWO HOUR FIRE AND/ OR

SMOKE PARTITION CONSTRUCTION

ONE HOUR FIRE AND/ OR SMOKE WALL

ONE HOUR FIREWALL

TWO HOUR FIRE WALL

TWO HOUR SHAFTWALL

PRIORITY 2

TWO HOUR FIRE AND/ OR SMOKE WALL

NON-RATED WALL

PRIORITY 1 (HIGHEST)

PRIORITY 3

PRIORITY 4

PRIORITY 5 (LOWEST)

HOLLOW METAL FRAME

(AS APPLICABLE)

METAL STUDS

NON-RATED WALL

WALL PRIORITY LEGEND

HIGHER PRIORITY WALL

HIGHER PRIORITY WALL

RATED WALL AND/ OR

SMOKE PARTITION

ONE HOUR CONSTRUCTION

1. CONTRACTOR SHALL COORDINATE

LOCATIONS OF HORIZONTAL FASTENERS.

ISOMETRIC

PLAN

GENERAL NOTES:

CUT HORIZONTAL FASTENER FROM STUD

FASTEN AT BOTH ENDS WITH MIN.

4 TAPPING SCREWS.

MTL. STUDS @ 16" O.C. MAX.

WALL FINISH

HEADER

18 GA TRACK1/8 1 1/2-16

JAMB STUDS (FULL HEIGHT)

18 GA TRACK

FOR OPENINGS GREATER THAN 12'-0" STUDS

ARE SUPPORTED VERTICALLY BY STRUCTURE

AND HORIZONTALLY BY DIAGONAL BRACING.

OPENING HEADER JAMB STUDS

UP TO 4'-0"

4'-0" TO 8'-0"

8'-0" TO 12'-0"

2-6" 18 GA

2-8" 16 GA

2-8" 16 GA

(2) 20 GA

(3) 20 GA

(4) 20 GA

A

A

TYP

BOX HEADER SECTION A-A

1/8 1 1/2-24

1/8

BOX HEADER ELEVATION

INTERIOR HOLLOW METAL

DOOR OR WINDOW FRAME

METAL STUD TRACK

SCREW ATTACH TRACK

TO BOTH JAMB STUDS

EXTRA METAL STUD

1/2" CONTROL JOINT SPACING

INSTALL SUITABLE BACKING

AT RATED WALLS

2 - 2O GA. METAL STUDS

NOTE:

SEE GWB SYSTEM SYSTEM SPECIFICATIONS FOR

LOCATION OF CONTROL JOINTS

STOP STUD RUNNER @ BASE PLATE

HOLLOW STRUCTURAL SECTION

STEEL PLATE

STOP STUD RUNNER @ BASE PLATE

5/4 HARDWOOD

WOOD BLOCKINGWOOD BLOCKING

FOR WALL GREATER THAN 42" H.

R 1/ 2"

R 1/ 2"

HOLLOW STRUCTURAL SECTION

STEEL PLATE

WALL GUARD

WOOD BLOCKING

5/4 HARDWOOD ABOVE

STOP STUD RUNNER @ BASE PLATE

HSS3"x3"x3/16" @ 6'-0" O.C. MAX.

3/8" STEEL PLATE W/ 4 - 1/2"∅

HILTI HY150 EPOXY

ANCHORS W/ 2 1/8" EMBED INTO

CONCRETE

FLOOR LINE

HSS3"x3"x3/16" @ 6'-0" O.C. MAX.

FOR WALL GREATER THAN 42" H.

3/16"

CONTACT ARCHITECT:

WITH DIMENSIONS OF TRACK RECESS

AND SLAB THICKNESS WHERE

EMBEDS FALL INTO OR ADJACENT

TO GROUTED TRACK RECESS

1 1/2" 3 1/2" 1 1/2"

1/

2"

1/ 2"

1/

2"

1/ 2"

C

SECTION CC

C

STOP STUD RUNNER @ BASE PLATE

STEEL PLATE

STOP STUD RUNNER @ BASE PLATE

CHANNEL

WOOD BLOCKING

CHANNEL

WOOD BLOCKING

FOR WALL LESS THAN 42" H.

R 1/ 2"

R 1/ 2"

STEEL PLATE

CHANNEL

WOOD BLOCKING

5/4 HARDWOOD

WALL GUARD

5/4 HARDWOOD ABOVE

3/8" STEEL PLATE W/ 4 - 1/2"∅

HILTI HY150 EPOXY ANCHORS W/ 2

1/8" EMBED INTO CONCRETE

FLOOR LINE

CONTACT ARCHITECT:

WITH DIMENSIONS OF TRACK RECESS

AND SLAB THICKNESS WHERE

EMBEDS FALL INTO OR ADJACENT

TO GROUTED TRACK RECESS

C6x8.2 @ 4'-0" O.C. MAX.C6x8.2 @ 4'-0" O.C. MAX.

C6x8.2 @ 4'-0" O.C. MAX.

FOR WALL LESS THAN 42" H.

B

3/16"

1 1/2" 3 1/2" 1 1/2"

1/

2"

1/ 2"

1/

2"

1/ 2"

B

SECTION BB

SEE PLAN FOR WALL TYPE

SHIM AS REQUIRED LEAD BATTEN

ONLY REQUIRED AT JOINTS

5/8" F.R. GWB BOTH SIDES

3/8" DIA LEAD BUTTON

NOTE:

LOCATE BATTENS PER UL DESIGN

AT RATED WALLS.

2" WIDE LEAD BATTEN AT EACH

VERTICAL JOINT

SEE PLAN FOR WALL TYPE

SHIM AS REQUIRED LEAD BATTEN

ONLY REQUIRED AT JOINTS

5/8" F.R. GWB BOTH SIDES

NOTE:

LOCATE BATTENS PER UL DESIGN

AT RATED WALLS.

4" WIDE LEAD BATTEN AT CORNER

3/8" DIA LEAD BUTTON

SEE PLAN FOR WALL TYPE

SHIM AS REQUIRED LEAD BATTEN

ONLY REQUIRED AT JOINTS

5/8" F.R. GWB BOTH SIDES

4" WIDE LEAD BATTEN AT CORNER

NOTE:

LOCATE BATTENS PER UL DESIGN

AT RATED WALLS.

ELECTRICAL BOX LEAD LINER

ELECTRICAL BOX

3/8" DIA LEAD BUTTON

NON-LOAD BEARING WALL

FRAMING SYSTEM - SEE PLAN

3 LAYERS 5/8" GWB SYSTEM

2 LAYERS 5/8" GWB SYSTEM

2"x1/2" PERIMETER GASKET

SOUND INSULATION (MIN 5")

RESILIENT CHANNEL, 24" O.C.

SOUND INSULATION

WALL TYPE PER FLOOR PLANS -

EXTEND GWB TO SLAB ON

CORRIDOR SIDE OF CURB

6"H X 10"W CONCRETE CURB

W/ #4 DOWELS @ 48" O.C.

WATERPROOF FLOORING EXTENDED

UP AND OVER CONCRETE CURB

T Y

P

4"

METAL STUD MATCH GAUGE

OF VERTICAL STUDS

SEE FLOOR PLANS

FOR WALL TYPE

CORRIDOR

ROOM SIDE

10" CONT. 22 GA. SHEET

METAL BACKING AT BASE

(CORRIDOR SIDE ONLY)

FIRESTOP

STRUCTURAL DECK

TYPE S SCREWS

NOTE: FIRESTOP SYSTEM IS REQUIRED ONLY AT RATED WALL REFER TO LIFE SAFETY SERIES FOR LOCATIONS. USE

APPROPRIATE UL LISTED ASSEMBLY BASED ON WALL AND STRUCTURAL DECK CONSTRUCTION.

BLAZEFLAME (DSL2)

SLOTTED DEFLECTION TRACK

SECURE TO STRUCTURE WITH TWO

1/4" DRILLED ANCHORS AT 24" O.C.

BLAZEFLAME PERIMETER L-BEAD

SEE PLAN

VARIES

5/ 8"

GYPSUM WALL BOARD

FIRE RATING - 1 HOUR

STC RATING - 45-49

TEST: U.L. Design No. U465

TEST: TL 99-103

RATING INFORMATION

SAME AS "A" WITH

NO SOUND INSULATION

SAME AS "A6" WITH

NO SOUND INSULATION

6" NON-LOAD BEARING WALL

FRAMING SYSTEM

3 5/8" NON-LOAD BEARING WALL

FRAMING SYSTEM

STC RATING - 40 TEST: TL 99-160

STRUCTURAL DECK

CEILING LINE

5/8" F.R. GWB BOTH SIDES

FIRESTOP BOTH SIDES

(FIRE AND/ OR SMOKE WALL)

FLOOR LINE

SECTION

SOUND INSULATION

A A6

A1 A7

A

A1

A6

A7

NO SCALE

WALL TYPE

A7A6A1A

A-002

RATING INFORMATION

FIRE RATING - NON-RATED

3 5/8" NON-LOAD BEARING WALL

FRAMING SYSTEM

2 1/2" NON-LOAD BEARING WALL

FRAMING SYSTEM

1" @ F & F6

FACE OF COLUMN OR WALL

(NEW OR EXISTING)

1 5/8" NON-LOAD BEARING WALL

FRAMING SYSTEM

FCONT. 25 GA SHEET METAL CLOSURE

STRUCTURAL DECK

FIRESTOP BOTH SIDES

(FIRE AND/ OR SMOKE WALL)

FLOOR LINE

CEILING LINE

5/8" GWB

6" NON-LOAD BEARING WALL

FRAMING SYSTEM

M

IN6"

F

F1

F2

F6

1"

SECTION

NO SCALE

WALL TYPE

F6F2F1F

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMP

321 4 5 6 7 8 9 10

Alesia Architecture P.C.

3705 North 200th Street Elkhorn, Nebraska 68022 Phone: (402) 291-6941 o n e e ig h th i n c h o n e f o o t th re e i n c h e s o n e f o o t o n e a n d o n e h a lf i n c h e s o n e f o o t o n e i n c h o n e f o o t th re e q u a rt e rs i n c h o n e f o o t o n e h a lf i n c h o n e f o o t th re e e ig h th s i n c h o n e f o o t o n e q u a rt e r in c h o n e f o o t

CONSTRUCTION

DOCUMENTS

PREPARE SITE FOR CHOICE

DINING EQUIPMENT

589A7-23-305

5500 E KELLOGG AVE, WICHITA, KS

A

B

C

D

E

F

A u to d e s k D o c s /1

A -2

-3

P re p a re

S it e f o r C h o ic e

D in in g /5

A -2

-3

.B

.A rc h

R

-E x is ti n g

.r v t

/2

/2

:4

:1

P

M

A-002

PARTITION DETAILS & DETAILS

RJO JJG05/17/2024

1 1/2" = 1'-0"1

WALL PRIORITY LEGEND

1 1/2" = 1'-0"2

TYP. WALL BACKING DETAIL

1 1/2" = 1'-0"3

HEADER SCHEDULE

1 1/2" = 1'-0"4

TYPICAL CONTROL JOINT

1 1/2" = 1'-0"14

HIGH WALL TERMINATION

1 1/2" = 1'-0"15

HIGH WALL LATERAL SUPPORT

1 1/2" = 1'-0"16

LOW WALL TERMINATION

1 1/2" = 1'-0"17

LOW WALL LATERAL SUPPORT

1 1/2" = 1'-0"9

WALL TYPE 'R' DETAIL

1 1/2" = 1'-0"10

WALL TYPE 'R' DETAIL

1 1/2" = 1'-0"11

WALL TYPE 'R' DETAIL

1 1/2" = 1'-0"12

WALL TYPE 'S' DETAIL

1 1/2" = 1'-0"13

MECH RM CURB, PERIM WALLS

3" = 1'-0"5

FIRE BLKG AT OPEN CAVITY

3" = 1'-0"6

BASE METAL BACKING DETAIL

3" = 1'-0"8

STUD WALL ATTACH. TO CONC. DECK

SHIELDING SCHEDULE

ROOM NUMBER ROOM NAME

MININUM THICKNESS OF LEAD SHIELDING

NORTH EAST SOUTH WEST

NOTE: EXISTING WALLS SHALL RECEIVE WALL TYPE "N" IN ROOMS REQUIRING SHIELDING

INTERIOR PARTITION NOTES

1. UPGRADE GWB TO TILE BACKER (MR GWB) WHERE CALLED FOR BY SPEC. SECTION 09 22 16 AND

WHERE DRAWINGS CALL FOR ADHERED CSMU TILE VENEER.

2. EXTEND FIRE RATED WALL CONSTRUCTION BEHIND RECESSED OR BUILT-IN EQUIPMENT SUCH AS FIRE EXTINGUISHER CABINETS (FEC), ELECTRICAL WATER COOLERS (EWC), ELECTRIC PANELS, ETC., UNO.

3. PROVIDE AND INSTALL ALL STIFFENERS, BRACING, BACK-UP PLATES & SUPPORTING BRACKETS

REQUIRED FOR THE INSTALLATION OF ALL CASEWORK AND OF ALL FLOOR MOUNTED OR

SUSPENDED MECHANICAL, ELECTRICAL OR LABORATORY EQUIPMENT.

4. WHERE HVAC OR OTHER MECHANICAL, ELECTRICAL AND PLUMBING ITEMS PENETRATE

PARTITIONS, STUDS SHALL BE BRACED AND FRAMED TO STRUCTURE AS REQUIRED TO PROVIDE

ADEQUATE SUPPORT. ALL PENETRATIONS THROUGH RATED WALLS SHALL BE SEALED TO

PROVIDE FIRE, SMOKE, AND/OR ACOUSTICAL ISOLATION OF SPACES WITH APPROPRIATE

FIRESTOP MATERIAL.

5. COORDINATE METAL STUD GAUGE WITH PRE-APPROVED EQUIPMENT ANCHORAGE. WHERE A

DISCREPANCY OCCURS, THE MORE STRINGENT REQUIREMENT SHALL GOVERN.

6. WHERE COLUMN FURRING STUDS EXCEED THE MANUFACTURER'S RECOMMENDED LIMITING

HEIGHTS, STUDS SHALL BE BRACED BACK TO THE STRUCTURE AS REQUIRED.

7. THERE SHALL BE NO BACK-TO-BACK ELECTRICAL, TELEPHONE, OR OTHER OUTLETS, EXCEPT

WHERE SPECIFICALLY SHOWN. AT ACOUSTICALLY SENSITIVE AREAS, SUCH AS EXAM ROOMS,

OFFICES, CLASSROOMS, ETC. OFFSET OUTLETS IN OPPOSITE SIDES OF THE WALL BY AT LEAST

TWO STUD CAVITIES.

8. WALL BASE NOT SHOWN ON WALL TYPES FOR CLARITY.

9. WHERE 'SEALANT' IS INDICATED ON WALL TYPES, PROVIDE ACOUSTIC (SOUND) SEALANT AT

NON-RATED WALLS AND FIRE-RATED SEALANT AT RATED WALLS AS REQUIRED BY FIRE RATING

TEST NUMBER.

10. PROVIDE SOUND INSULATION AS REQUIRED TO MEET STC RATING INDICATED ON WALL TYPE.

PROVIDE SOUND INSULATION IN WALLS AROUND THE FOLLOWING SPACES: CLASSROOMS,

CONFERENCE ROOMS, OFFICES, OPERATING ROOMS, EXAM ROOMS, PROCEDURE ROOMS,

COMMUNICATION AND ELECTRICAL ROOMS, MECHANICAL ROOMS, MECHANICAL AND ELEVATOR

SHAFTS, & TOILET AND LOCKER ROOMS. SOUND INSULATION IS NOT REQUIRED IN WALLS WITH

CASED OPENINGS OR OTHER UNENCLOSED OPENINGS. SOUND INSULATION IS NOT REQUIRED IN

ABOVE-CEILING WALL CAVITIES LOCATED OVER DOORS AND BORROWED LITES.

1 1/2" = 1'-0"19

WALL TYPE A

1 1/2" = 1'-0"18

WALL TYPE F

Mark Revisions: Date:

A

R C H I T E

C

T

S T A T E

O F N E B

R A S K A

05/17/2024

RICHARD

JOSEPH

DN

J

WR

J

W ,1

J J

F

J

SD

J J

J J

J J

J

W,1

J

F

SD

R E

X

T

T

2 2

JJ

J

F A

C P

S S S S S S S S S S S S

S S

S

SS

S S

S S

S S

S

S S S S S S S

HOT

PRODUCTION/TRAY

ASSEMBLY

LINE

COLD FOOD

PREP

103A

1313 1313 1313

33 33 33

OFFICE

100B

STAFF

TOILET

105A

KITCHEN/DIETETICS

KITCHEN/DIETETICS

KITCHEN/DIETETICS

STAIR

1STAIR

TELEPHONE

CLOSET

CONFERENCE

ROOM

STORAGE

GENERAL

105C

ELEVATOR

1ELEV

CORRIDOR

1CORR-DIET

CORRIDOR

1CORR

DISH

WASHER

WALK-IN

REFRIGERATOR

KITCHEN/DIETETICS

104A

KITCHEN/DIETETICS

FREEZER

OFFICE

108A

OFFICE

STAFF

WORKROOM

KITCHEN

MANAGER

107A

DEMOLITION PLAN LEGEND

FULL HEIGHT ONE-HOUR FIRE RATED TEMPORARY

PARTITION

ELEMENT TO BE REMOVED, TYPICAL

EXISTING CONSTRUCTION TO REMAIN UNO.

INDICATES AREA TO BE REMOVED, TYPICAL

TRUE

KEY PLAN

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMP

321 4 5 6 7 8 9 10

Alesia Architecture P.C.

3705 North 200th Street Elkhorn, Nebraska 68022 Phone: (402) 291-6941 o n e e ig h th i n c h o n e f o o t th re e i n c h e s o n e f o o t o n e a n d o n e h a lf i n c h e s o n e f o o t o n e i n c h o n e f o o t th re e q u a rt e rs i n c h o n e f o o t o n e h a lf i n c h o n e f o o t th re e e ig h th s i n c h o n e f o o t o n e q u a rt e r in c h o n e f o o t

CONSTRUCTION

DOCUMENTS

PREPARE SITE FOR CHOICE

DINING EQUIPMENT

589A7-23-305

5500 E KELLOGG AVE, WICHITA, KS

A

B

C

D

E

F

A u to d e s k D o c s /1

A -2

-3

P re p a re

S it e f o r C h o ic e

D in in g /5

A -2

-3

.B

.A rc h

R

-E x is ti n g

.r v t

/2

/2

:4

:2

P

M

AD101

FIRST FLOOR - DEMOLITION PLAN

RJO JJG05/17/2024

1/4" = 1'-0"1

FIRST FLOOR - DEMOLITION FLOOR PLAN

GENERAL DEMOLITION NOTES

1 DASHED BOLD LINES INDICATE EXTENT OF DEMOLITION INCLUDING THE FOLLOWING:

* INTERIOR PARTITIONS (REMOVED TO STRUCTURE)

* CEILINGS, INCLUDING CEILING SUSPENSION SYSTEM, MISC. STEEL SUPPORTS FOR SUSPENDED

EQUIPMENT, SUSPENDED EQUIPMENT, LIGHT FIXTURES, DIFFUSERS AND GRILLES ETC.

* FLOOR FINISHES (TO CONCRETE) INCLUDING CARPET, RVT, SHEET VINYL, CERAMIC TILE, QUARRY

TILE, BRICK PAVERS, ETC.

* DOORS AND FRAMES UNLESS NOTED OTHERWISE IN DOOR SCHEDULE

* WINDOW GLAZING AND FRAMES UNLESS NOTED OTHERWISE

* BRICK AND BACK-UP WALL SYSTEM

* CABINETWORK, SHELVING, BASES

* TOILET PARTITIONS AND ACCESSORIES

* TACK BOARDS, MARKER BOARDS, PEGBOARDS, DISPLAY BOARDS

* EQUIPMENT ITEMS

* PLUMBING FIXTURES

2 DASHED BOLD LINES INDICATE EXTEND OF DEMOLITION INCLUDING THE FOLLOWING:

3 CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS.

4 ALL LIGHT OR HALFTONE LINES INDICATE EXISTING TO REMAIN.

5 SEE SPECIFICATIONS SECTIONS FOR CUTTING AND PATCHING AND DEMOLITION 02 41 00.

6 SEE ROOM FINISH SCHEDULE, MECHANICAL PLANS, AND ELECTRICAL PLANS FOR EXTENT OF NEW

CEILING CONSTRUCTION OR CEILING PATCHING IN EXISTING AREAS.

7 SEE ROOM FINISH SCHEDULE FOR EXTENT OF NEW FLOORING MATERIAL IN EXISTING AREAS.

8 SEE ROOM FINISH SCHEDULE FOR EXTENT OF NEW WALL COVERING MATERIAL IN EXISTING AREAS.

WHERE NEW FINISHES ARE REQUIRED REMOVE EXISTING WALL FINISHES, (TEXRURED PLASTIC COATING, VINYL WALL COVERING, PANELING, BASE, ETC.).

9 CONTRACTOR TO VERIFY ALL WALL CONSTRUCTION & FINISHES NOTED FOR REMOVAL. TAKE INTO

ACCOUNT ANY DISCREPANCY AND MAKE PROPER ADJUSTMENT TO ACCOMPLISH REQUIRED

CONSTRUCTION & FINISHES. IF STRUCTURAL INTEGRITY IS VIOLATED, CONTACT ARCHITECT.

COORDINATE PHASING WITH OWNER

10 COORDINATE REMOVEL OF FURNITURE AND EXISTING EQUIPMENT WITH OWNER.

11 REFER TO EQUIPMENT SCHEDULE 11700S FOR NEW LOCATIONS OF EXISTING EQUIPMENT, ETC.

12 SAW CUT EDGES OF EXISTING FLOOR SLAB FOR REMOVAL AND INSTALLATION OF UTILITIES. REFER TO

MECHANICAL AND ELECTRICAL DRAWINGS.

13 REMOVE FURRING OR GWB ONLY WHERE REQUIRED TO COMPLETE CONSTRUCTION. PATCH AND MATCH WALLS AS REQUIRED TO COMPLETE AND MATCH EXISTING CONDITIONS, UNLESS AN ALTERNATIVE

MATERIAL AND FINISH IS INDICATED.

14 REMOVE CEILINGS ONLY AS REQUIRED FOR NEW CONSTRUCTION. REINSTALL, REPLACE OR PATCH AS

REQUIRED.

DEMOLITION KEYNOTES

3 EXISTING KITCHEN EQUIPMENT TO BE REMOVED. COORDINATE WITH VA

COR.

7 DOOR AND FRAME TO BE REMOVED.

9 REMOVE EXISTING WALL IN ITS ENTIRETY.

12 WINDOW AND FRAME TO BE REMOVED.

13 REMOVE EXISTING FLOOR FINISH TO BARE CONCRETE IN THIS AREA &

PREP FOR NEW FLOOR FINISHES. COORDINATE EXTENTS WITH VA COR.

15 REMOVE EXISTING CEILING AND ASSOCIATED FRAMING. COORDINATE

EXTENTS WITH NEW CONSTRUCTION.

19 REMOVE EXISTING RAISED CONCRETE SLAB DOWN TO EXISTING FLOOR

LEVEL.

Mark Revisions: Date:

A

R C H I T E

C

T

S T A T E

O F N E B

R A S K A

05/17/2024

RICHARD

JOSEPH

J

J

W ,1

J

F

J

SD

J J

J J

W,1

J

F

SD

R E

X

2 2

S ,D a a

J

F A

C P

G G

G G G

J

S S S S S S S S S S S S

S S

S

SS

S S

S S

S S

S

S S S S S S S

SUPERVISORS

OFFICE

MULTIPURPOSE

ROOM

STAFF

BREAKROOM

STAFF

WORKROOM

KITCHEN

MANAGER

107A

HOT

PRODUCTION/TRAY

ASSEMBLY

LINE

COLD FOOD

PREP

103A

QH901

AA

F1

'-1

1/

2"

'-1

1/ 2"

'-3

/4

INFILL EXISTING WINDOW OPENING

12'-2 1/4"

10'-0 1/4"

15'-2 1/2"

1'-7" 12'-2"

W1

QH901

QH901 5

F1

A6

QH901

F1

'-8

9 1/2" 13'-1 1/2"

'-2

/4

1/ 2"

FE

FE

OFFICE

100B

STAFF

TOILET

105A

KITCHEN/DIETETICS

KITCHEN/DIETETICS

KITCHEN/DIETETICS

STAIR

1STAIR

TELEPHONE

CLOSET

CONFERENCE

ROOM

STORAGE

GENERAL

105C

ELEVATOR

1ELEV

CORRIDOR

1CORR-DIET

CORRIDOR

1CORR

DISH

WASHER

WALK-IN

REFRIGERATOR

KITCHEN/DIETETICS

104A

KITCHEN/DIETETICS

FREEZER

TRUE

KEY PLAN

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMP

321 4 5 6 7 8 9 10

Alesia Architecture P.C.

3705 North 200th Street Elkhorn, Nebraska 68022 Phone: (402) 291-6941 o n e e ig h th i n c h o n e f o o t th re e i n c h e s o n e f o o t o n e a n d o n e h a lf i n c h e s o n e f o o t o n e i n c h o n e f o o t th re e q u a rt e rs i n c h o n e f o o t o n e h a lf i n c h o n e f o o t th re e e ig h th s i n c h o n e f o o t o n e q u a rt e r in c h o n e f o o t

CONSTRUCTION

DOCUMENTS

PREPARE SITE FOR CHOICE

DINING EQUIPMENT

589A7-23-305

5500 E KELLOGG AVE, WICHITA, KS

A

B

C

D

E

F

A u to d e s k D o c s /1

A -2

-3

P re p a re

S it e f o r C h o ic e

D in in g /5

A -2

-3

.B

.A rc h

R

-E x is ti n g

.r v t

/2

/2

:4

:0

P

M

AE101

FIRST FLOOR - FLOOR PLAN

RJO JJG05/17/2024

GENERAL NOTES

1 ALL NEW CONSTRUCTION IS INDICATED BOLD OR FULL TONE.

2 ALL INTERIOR WALLS WILL BE TYPE "A" CONSTRUCTION UNLESS OTHERWISE INDICATED. REFER TO

SHEET A-002.

3 ALL INTERIOR WALLS WILL BE TYPE "A" CONSTRUCTION UNLESS OTHERWISE INDICATED. REFER TO

SHEET A-002

4 ALL METAL STUD AND GYPSUM WALLBOARD PARTITIONS ARE DIMENSIONED TO THE OUTSIDE FACE AND

TO COLUMN GRID UNLESS OTHERWISE NOTED.

5 WHEN WALL PARTITIONS OF DIFFERENT FIRE RATING INTERSECT, THE HIGHEST RATED PARTITION TAKES

PRECEDENT. MAINTAIN RATING BEHIND FIRE EXTINGUISHER CABINETS, ETC.

6 CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS PRIOR TO CONSTRUCTION.

7 REFER TO THE Q SERIES FOR ARCHITECTURAL EQUIPMENT NUMBERS.

8 REFER TO SHEET A-003 FOR TYPICAL BACKING DETAIL WITHIN INTERIOR WALL PARTITION, HANDRAILS, CUBICAL CURTAIN TRACKS, CORNER GUARDS ETC.

9 ALL EXISTING TO REMAIN CEILING AND WALL GRILLES, DIFFUSERS AND LIGHTS ETC. TO BE CLEANED.

10 VERIFY THAT THE EXISTING WALLS REQUIRING FIRE RATING ARE MAINTAINED, REPAIRED AND EXTENDED

TO STRUCTURE.

11 ALL CORRIDOR WALLS ARE REQUIRED TO BE SMOKE TIGHT, WHETHER THEY ARE FIRE RATED OR NOT.

REPAIR AND EXTEND AT LEAST THE CORRIDOR SIDE OF NON-FIRE RATED CORRIDOR WALLS TO

STRUCTURE, UNLESS NOTED OTHERWISE NOTED. SEE PARTITION TYPES SHEET.

12 REFER TO LIFE SAFETY PLANS FOR LOCATION OF REQUIRED FIRE WALLS.

13 REFER TO SPECIFCATIONS FOR EXPANSION JOINT ASSEMBLIES. PROVIDE FIRE RATED EXPANSION

JOINTS IN RATED FIRE WALLS, REFER TO LIFE SAFETY SERIES FOR FIRE RATINGS.

14 ALL FURNITURE SHOWN HALF TONE WILL BE OWNER FURNISHED AND OWNER INSTALLED.

1/4" = 1'-0"1

FIRST FLOOR - FLOOR PLAN

REF

Mark Revisions: Date:

A

R C H I T E

C

T

S T A T E

O F N E B

R A S K A

05/17/2024

RICHARD

JOSEPH

S

WAPS

S

WAP

WAP

WAP

S

S

WAP

J

J

J

R

R

R

RR

R

R

R

R

R

R

EXISTING GYPSUM WALL BOARD CEILING

EXISTING SUSPENDED ACOUSTICAL REMAIN

EXISTING SUPPLY AIR GRILLE - SEE MECHANICAL

EXISTING RETURN AIR GRILLE - SEE MECHANICAL

EXISTING RECESSED 2X2 LIGHT FIXTURE - SEE ELECTRICAL

EXISTING RECESSED 2X4 LIGHT FIXTURE - SEE ELECTRICAL

STRIP LIGHTING

CAN LIGHT

EXIT LIGHT

WIRELESS ACCESS POINT

SPEAKER

SMOKE DETECTOR

OCCUPANCY SENSOR

VIDEO SURVEILLANCE CAMERA

REFLECTED CEILING LEGEND

GYPSUM WALL BOARD CEILING

SUSPENDED ACOUSTICAL CEILING

SUPPLY AIR GRILLE - SEE MECHANICAL

RETURN AIR GRILLE TO - SEE MECHANICAL

RECESSED 2X2 LIGHT FIXTURE - SEE ELECTRICAL

RECESSED 2X4 LIGHT FIXTURE - SEE ELECTRICAL

STRIP LIGHTING

CAN LIGHT

EXIT LIGHT

WIRELESS ACCESS POINT

SPEAKER

SMOKE DETECTOR

OCCUPANCY SENSOR

VIDEO SURVEILLANCE CAMERA

SS

SDOS

OSOS

WAPWAP

CCTVCCTV

SUPERVISORS

OFFICE

MULTIPURPOSE

ROOM

STAFF

BREAKROOM

STAFF

WORKROOM

KITCHEN

MANAGER

107A

HOT

PRODUCTION/TRAY

ASSEMBLY

LINE

COLD FOOD

PREP

103A

OFFICE

100B

STAFF

TOILET

105A

KITCHEN/DIETETICS

KITCHEN/DIETETICS

KITCHEN/DIETETICS

STAIR

1STAIR

TELEPHONE

CLOSET

CONFERENCE

ROOM

STORAGE

GENERAL

105C

ELEVATOR

1ELEV

CORRIDOR

1CORR-DIET

CORRIDOR

1CORR

DISH

WASHER

WALK-IN

REFRIGERATOR

KITCHEN/DIETETICS

104A

KITCHEN/DIETETICS

FREEZER

TRUE

KEY PLAN

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMP

321 4 5 6 7 8 9 10

Alesia Architecture P.C.

3705 North 200th Street Elkhorn, Nebraska 68022 Phone: (402) 291-6941 o n e e ig h th i n c h o n e f o o t th re e i n c h e s o n e f o o t o n e a n d o n e h a lf i n c h e s o n e f o o t o n e i n c h o n e f o o t th re e q u a rt e rs i n c h o n e f o o t o n e h a lf i n c h o n e f o o t th re e e ig h th s i n c h o n e f o o t o n e q u a rt e r in c h o n e f o o t

CONSTRUCTION

DOCUMENTS

PREPARE SITE FOR CHOICE

DINING EQUIPMENT

589A7-23-305

5500 E KELLOGG AVE, WICHITA, KS

A

B

C

D

E

F

A u to d e s k D o c s /1

A -2

-3

P re p a re

S it e f o r C h o ic e

D in in g /5

A -2

-3

.B

.A rc h

R

-E x is ti n g

.r v t

/2

/2

:4

:1

P

M

AC101

FIRST FLOOR - REFLECTED CEILING

PLAN

RJO JJG05/17/2024

GENERAL REFLECTED CEILING NOTES

1 PROVIDE GYPSUM WALL BOARD AND METAL STUD BULK HEADS WHERE CEILINGS OF DIFFERENT HEIGHTS

ABUT. DO NOT BUILD BULKHEADS OF ACOUSTICAL CEILING MATERIALS UNLESS SPECIFICALLY DETAILED.

2 REFER TO MECHANICAL DRAWINGS (M SERIES) FOR QUANTITY AND TYPE OF DIFFUSERS, RETURN AIR GRILLES, AND EXHAUST GRILLES. SCRIBE CEILING MATERIALS CAREFULLY FOR A TIGHT FIT.

3 REFER TO ELECTRICAL DRAWINGS (E SERIES) FOR QUANTITY AND TYPE OF LIGHTS, SPEAKERS, DETECTORS, POWER OUTLETS, ETC. SCRIBE CEILING MATERIALS CAREFULLY. WHERE NO DEVICES ARE SHOWN ON PLANS, FIELD VERIFY LOCATION & QUANTITY OF DEVICES IN EXISTING CEILING. THESE

DEVICES WILL BE RELOCATED TO THE NEW CEILING.

4 ALTHOUGH NOT SPECIFICALLY SHOWN, THE ENTIRE PROJECT HAS FIRE SPRINKLER HEADS IN CEILING.

SCRIBE CEILING MATERIALS CAREFULLY FOR A TIGHT FIT.

5 ACOUSTIC TILE CEILING TO BE AT-1 UNLESS NOTED OTHERWISE.

6 REFER TO ROOM FINISH SCHEDULE FOR CEILING HEIGHTS AND MATERIAL LOCATIONS.

7 REFER TO ROOM FINISH SCHEDULE FOR THE EXTENT OF GRID SYSTEM. REFLECTED CEILING PLANS

SHOW TILE PATTERNS.

8 CONTRACTOR TO FIELD VERIFY EXTENT OF CEILING REPLACEMENT. CONTRACTOR TO COORDINATE WITH

ALL TRADES.

9 ALL EXISTING TO REMAIN GRILLES, DIFFUSERS AND LIGHTS ETC. TO BE CLEANED

10 CONTRACTOR TO COORDINATE WITH ALL TRADES.

11 UNLESS NOTED OTHERWISE, TYPICAL CEILING HEIGHT TO BE 9'-0".

1/4" = 1'-0"1

FIRST FLOOR - REFLECTED CEILING PLAN

Mark Revisions: Date:

A

R C H I T E

C

T

S T A T E

O F N E B

R A S K A

05/17/2024

RICHARD

JOSEPH

8"

8"

8"

6" 6"6" 6"

F

FLUSH

FG

FLUSH

FG2

FLUSH

@ RATED

DOORS

@ NON-RATED

DOORS

* 4"

8"

N

FLUSH

8"

6" 6"

HG

FLUSH

S1

MANUAL SLIDING DOOR

2"

SCHEDULE

SEE DOOR 2"

HOLLOW METAL

2" S

E E

D O

O R

S C

H E

D U

LE

2"

SCHEDULE

SEE DOOR 2" 1 3/8"

SCHEDULE

SEE DOOR 2 5/8"

3/

8" S

E E

D O

O R

S C

H E

D U

LE

2"

SCHEDULE

SEE DOOR 2" 2"

SCHEDULE

SEE DOOR 2" 2"

SCHEDULE

SEE DOOR 2"

4" S

E E

D O

O R

S C

H E

D U

LE

2"

SCHEDULE

SEE DOOR 2" 2"

SCHEDULE

SEE DOOR 2"

5/

8"

1 3/8"

SCHEDULE

SEE DOOR 2 5/8"

5/

8"

HOSPITAL

STOPS @

INTERIOR

DOORS ONLY

EMERGENCY

RELEASE

STOPS 1H

HOLLOW METAL

HOLLOW METAL DOUBLE EGRESS

HOLLOW METAL

HOLLOW METAL CASED OPENING

HOLLOW METAL

5H

HOLLOW METAL

HOLLOW METAL

HOLLOW METAL DOUBLE EGRESS

HOSPITAL

STOPS @

INTERIOR

DOORS

ONLY

2" S

E E

D O

O R

S C

H E

D U

LE

2" S

E E

D O

O R

S C

H E

D U

LE

2" S

E E

D O

O R

S C

H E

D U

LE

4" S

E E

D O

O R

S C

H E

D U

LE

4" S

E E

D O

O R

S C

H E

D U

LE

4" S

E E

D O

O R

S C

H E

D U

LE

HOLLOW METAL FRAME

BOTTOM OF FRAME

4" MATCH EXISTING FRAMES

45°

TYP.

4"

HOLLOW METAL FRAME

WALL - SEE

PLAN FOR TYPE

WALL (WHERE OCCURS)

- SEE PLAN FOR TYPE

W1

AL

T.O. SLAB T.O. SLAB

3' -0

2"

3' -8

2"

3' -0

4'

-0

2"

EQ

2"

EQ.

2"

EQ.

2"

12'-2 1/4"

LG-1LG-1 LG-1

SEE PLAN

VARIES

S E

E P

LA

N

V A

R

IE

S

WALL - SEE PLAN

FOR TYPE

SEALANT - EA. SIDE

& ALL AROUND - TYP.

HOLLOW METAL

FRAME

4" 2"

WALL - SEE PLAN

FOR TYPE

ADJACENT WALL

WHERE OCCURS

HOLLOW METAL

FRAME

SEALANT - EA. SIDE

ALL AROUND - TYP.

H.M. HEAD DETAIL H.M. JAMB DETAIL

SOFFIT NOT TYP. ON

ALL HM DOOR FRAMES.

- REFER TO HARDWARE

SET

SEE PLAN

VARIES

WALL - SEE PLAN

FOR TYPE

SEALANT - EA. SIDE

& ALL AROUND - TYP.

WALL - SEE PLAN

FOR TYPE

SEALANT - EA. SIDE

& ALL AROUND - TYP.

WINDOW HEAD DETAIL

GLAZING

WINDOW SILL DETAIL

GLAZING

ALUM FRAME

ALUM FRAME

TRUE

KEY PLAN

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMP

321 4 5 6 7 8 9 10

Alesia Architecture P.C.

3705 North 200th Street Elkhorn, Nebraska 68022 Phone: (402) 291-6941 o n e e ig h th i n c h o n e f o o t th re e i n c h e s o n e f o o t o n e a n d o n e h a lf i n c h e s o n e f o o t o n e i n c h o n e f o o t th re e q u a rt e rs i n c h o n e f o o t o n e h a lf i n c h o n e f o o t th re e e ig h th s i n c h o n e f o o t o n e q u a rt e r in c h o n e f o o t

CONSTRUCTION

DOCUMENTS

PREPARE SITE FOR CHOICE

DINING EQUIPMENT

589A7-23-305

5500 E KELLOGG AVE, WICHITA, KS

A

B

C

D

E

F

A u to d e s k D o c s /1

A -2

-3

P re p a re

S it e f o r C h o ic e

D in in g /5

A -2

-3

.B

.A rc h

R

-E x is ti n g

.r v t

/2

/2

:4

:2

P

M

AE701

DOOR AND WINDOW TYPES,

SCHEDULES, AND DETAILS

RJO JJG05/17/2024

DOOR SCHEDULE

DOOR NUMBER ROOM NAME DOOR SIZE HARDWARE DOOR MATERIAL DOOR TYPE DOOR FINISH FRAME TYPE

FRAME

MATERIAL FRAME FINISH FIRE RATING REMARKS

112 MULTIPURPOSE ROOM 3'-0" x 7'-0" HW-3G WD F STN-1 1 HM PT-2 45-MIN

113 SUPERVISORS OFFICE 3'-0" x 7'-0" HW-3G WD F STN-1 1 HM PT-2 45-MIN

KEY REMARKS

A

1/4" = 1'-0"1

DOOR TYPES

1/4" = 1'-0"2

FRAME TYPES

1 1/2" = 1'-0"5

HOSPITAL STOPS

1 1/2" = 1'-0"4

DOOR FRAME OFFSET

GLASS TYPE SCHEDULE

REF TYPE Description Thickness Remarks

LG-1 TYPE 1 CLEAR, LAMINATED TEMPERED FLOAT SEE SPECIFICATIONS --

GLASS TYPE SCHEDULE NOTES:

A: COMPLY WITH UL LEVEL 3 PROTECTION LEVEL, SPSA - SUPER POWER SMALL ARMS

B: SEE SPECIFICATION SECTION 08 80 00, SEALED GLASS UNITS WITH OPERABLE LOUVERS

C: PLASTIC THUMBWHEEL OPERATOR, ACCESSIBLE FROM BOTH SIDES

D: DOOR UNIT ASSEMBLY, COORDINATE WITH DOOR & HARDWARE SCHEDULE

1/4" = 1'-0"3

WINDOW TYPES

3" = 1'-0"6

DOOR DETAILS

3" = 1'-0"7

WINDOW DETAILS

Mark Revisions: Date:

A

R C H I T E

C

T

S T A T E

O F N E B

R A S K A

05/17/2024

RICHARD

JOSEPH

S S S S S S S S S S S S

S S

S

SS

S S

S S

S S

S

S S S S S S S

LVT-1 EPY-1

FLOOR FINISH LEGEND

OFFICE

100B

STAFF

TOILET

105A

KITCHEN/DIETETICS

KITCHEN/DIETETICS

KITCHEN/DIETETICS

STAIR

1STAIR

TELEPHONE

CLOSET

CONFERENCE

ROOM

STORAGE

GENERAL

105C

ELEVATOR

1ELEV

CORRIDOR

1CORR-DIET

CORRIDOR

1CORR

DISH

WASHER

WALK-IN

REFRIGERATOR

KITCHEN/DIETETICS

104A

KITCHEN/DIETETICS

FREEZER

4" 3'

-8

2"

4" INTEGRAL

COVE BASE

CT-1

CT-2

SUPERVISORS

OFFICE

MULTIPURPOSE

ROOM

STAFF

BREAKROOM

STAFF

WORKROOM

KITCHEN

MANAGER

107A

HOT

PRODUCTION/TRAY

ASSEMBLY

LINE

COLD FOOD

PREP

103A

CG-1

CG-1

CT-1/CT-2

CT-1/CT-2

CT-1/CT-2

CT-1/CT-2

CT-1/CT-2

2' -4

T

O T

.O . B

U

LL

N O

S E

T

IL

E 6'

-9

F .V

SIGN TYPE A

SIGN TYPE A

SIGN TYPE A

SIGN TYPE A

SIGN TYPE B

SIGN TYPE B

FRONT VIEW

0' - 10"

ROOM #

GRADE 2 BRAILLE

RAISED TACTILE TEXT,

HELVETICA BOLD (INSERT

A, ACCENT COLOR 1

BACKGROUND)

FRAME

/2

/4

/8

/4

0' - 0 1/2" 0' - 0 1/2"

/1

(INSERT B, ACCENT

COLOR 1 BACKGROUND)

6"

1/ 2"

T Y

P

SIGNAGE GRAPHIC

RIGHT LEFT CENTER

EQ EQ

M

IN

A

F F

ROOM SIGNAGE (TYP)

DOOR TAG (TYP)

OVERHEAD WALL

DIRECTIONAL

M

IN

A

F F

B

L O

F L

O W

E S

T T

C

DOOR HARDWARE (TYP)

HM FRAME (TYP)

FRONT VIEW SIDE VIEW

0' - 9"

VINYL APPLIED GRAPHICS,

HELVETICA BOLD

CONDENSED (INSERT A,

ACCENT COLOR "RED"

BACKGROUND)

ALUMINUM FRAME

0' - 1" 0' - 1"

/1

/4

/1

LINE 2

NOTES:

1. SAME MESSAGE ON BOTH FACES, UNO.

WALL

CONCEALED

MECHANICAL

FASTENER

0' - 2 1/2"

EQ EQ

FIRE EXTINGUISHER

SYMBOL

TRUE

KEY PLAN

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMP

321 4 5 6 7 8 9 10

Alesia Architecture P.C.

3705 North 200th Street Elkhorn, Nebraska 68022 Phone: (402) 291-6941 o n e e ig h th i n c h o n e f o o t th re e i n c h e s o n e f o o t o n e a n d o n e h a lf i n c h e s o n e f o o t o n e i n c h o n e f o o t th re e q u a rt e rs i n c h o n e f o o t o n e h a lf i n c h o n e f o o t th re e e ig h th s i n c h o n e f o o t o n e q u a rt e r in c h o n e f o o t

CONSTRUCTION

DOCUMENTS

PREPARE SITE FOR CHOICE

DINING EQUIPMENT

589A7-23-305

5500 E KELLOGG AVE, WICHITA, KS

A

B

C

D

E

F

A u to d e s k D o c s /1

A -2

-3

P re p a re

S it e f o r C h o ic e

D in in g /5

A -2

-3

.B

.A rc h

R

-E x is ti n g

.r v t

/2

/2

:4

:1

P

M

IN101

ARCHITECTURAL FINISH PLAN,

SIGNAGE, & SCHEDULE

RJO JJG05/17/2024

ROOM FINISH SCHEDULE

ROOM

NUMBER

ROOM NAME FLOOR BASE

WALLS CEILING

REMARKS

NORTH EAST SOUTH WEST MATERIAL

103 HOT PRODUCTION/TRAY

ASSEMBLY LINE

EPY-1 EPY-1 ICB 4" EXISTING EXISTING EXISTING EXISTING EXISTING

103A COLD FOOD PREP EPY-1 EPY-1 ICB 4" EXISTING EXISTING EXISTING EXISTING EXISTING

106 KITCHEN/DIETETICS EPY-1 EPY-1 ICB 4" EXISTING EXISTING EXISTING EXISTING EXISTING

107 KITCHEN/DIETETICS EPY-1 EPY-1 ICB 4" EXISTING EXISTING EXISTING EXISTING EXISTING A.

107A KITCHEN MANAGER EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING

108 STAFF BREAKROOM LVT-1 RB-1 P-1 P-1 P-1 P-1 AT-1

109 STAFF WORKROOM EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING

112 MULTIPURPOSE ROOM EXISTING EXISTING P-1 P-1 P-1 P-1 AT-1

113 SUPERVISORS OFFICE LVT-1 RB-1 P-1 P-1 P-1 P-1 AT-1

KEY REMARKS

A REFER TO DETAIL 2/IN-101 & FINISH FLOOR PLAN FOR DETAILS.

1 1/2" = 1'-0"5

TILE WAINSCOT

1/4" = 1'-0"1

FIRST FLOOR - FINISH FLOOR PLAN

Mark Revisions: Date:

3" = 1'-0"2

SIGNAGE - TYPE A

1/4" = 1'-0"4

SIGNAGE MOUNTING HEIGHT

3" = 1'-0"3

SIGNAGE - TYPE B

A

R C H I T E

C

T

S T A T E

O F N E B

R A S K A

05/17/2024

RICHARD

JOSEPH

SS-1

BACKSPLASH

SS-1

PL-1

DRAWER

PULL

BASE AS SCHD.

1/

2" 2'

-4

/2

4"

2' -1

0"

1'-9"

2'-0"

SS-1

BACKSPLASH

SS-1

PL-1

PULL

ADJ. SHELF

METAL SHELF

STANDARDS

BASE AS SCHD.

1/

2" 2'

-4

/2

4"

2' -1

0"

1'-9"

2'-0"

PLASTIC LAMINATE

SCRIBE ANGLE

PL-1

ADJ. SHELF

CASEWORK SOFFIT

METAL SHELF

STANDARDS

PULL

UNDER CABINET

LIGHT - OPTIONAL

1'-2"

2" 2'

-6

CASEWORK GENERAL NOTES

1. ARCHITECTURAL CASEWORK ELEVATIONS ARE COVERED UNDER SPECIFICATION

SECTION 12 32 00.

2. ALL GENERAL NOTES ARE REQUIRED THROUGHOUT CASEWORK SERIES SHEETS UNLESS

NOTED OTHERWISE AT SPECIFIC LOCATION ON THE DRAWINGS.

3. COUNTERTOPS SHALL BE SOLID SURFACE MATERIAL SSM-1 25" DEEP AND HAVE 2"

MINIMUM RADIUS ON EXPOSED CORNERS.

4. BACKSPLASHES AND END SPLASHES MAY BE FIELD APPLIED.

5. CABINET WIDTHS AND DEPTHS SHOWN ARE NOMINAL. OUR INTENT IS TO USE CABINET

MANUFACTURER'S STANDARD PRODUCT SIZES.

6. WALL CABINETRY SHOWN AS 15" DEEP SHALL HAVE A MINIMUM CLEAR INSIDE DEPTH OF 13".

7. CASEWORK CONTRACTOR SHALL PROVIDE 1" MINIMUM SCRIBE AT ALL CABINET-WALL

ADJACENCIES.

8. CASEWORK CONTRACTOR SHALL PROVIDE CABLE GROMMET AT EACH UNDER COUNTER

POWER OR SYSTEMS OUTLET WHERE THERE IS AN EQUIPMENT ITEM SHOWN ON THE

COUNTERTOP. SEE E-SERIES DRAWINGS FOR COORDINATION.

9. TYPICAL LOCATION OF CORD GROMMET IS 2" IN FRONT OF BACKSPLASH AND 12" LEFT OF

CENTERLINE OF KNEESPACE/CABINET. SEE E-SERIES DRAWINGS FOR COORDINATION.

10. CASEWORK CONTRACTOR SHALL PROVIDE 2" VALANCE FOR TASK LIGHTING AS SHOWN IN

CASEWORK DETAILS. SEE E-SERIES DRAWINGS FOR COORDINATION OF TASK LIGHTS

LOCATIONS.

11. CASEWORK CONTRACTOR SHALL PROVIDE CUT-OUTS FOR COUNTERTOP SINKS AS

SCHEDULED IN P-SERIES DRAWINGS/SPECS.

12. WALL AND TALL CABINETRY SHALL HAVE VERTICAL GWB SOFFITS TO CEILING ABOVE.

VERIFY CEILING HEIGHTS WITH ROOM FINISH SCHEDULE AND/OR REFLECTED CEILING PLAN.

14. ELECTRICAL, MECHANICAL AND PLUMBING OUTLETS ARE SHOWN IN SOME LOCATIONS,

HOWEVER ALL OUTLETS MAY NOT BE SHOWN. COORDINATE LOCATIONS OF ALL OUTLETS

WITH APPLICABLE CONTRACTOR.

15. SEALING OF JOINTS, PROVIDE SILICONE SEALANT:

A. SEAL CASEWORK, COUNTERTOPS AND SPLASHES TO WALL, TO SEAL JOINTS.

1. SEALANT COLOR TO MATCH COUNTERTOP COLOR.

B. SEAL PERIMETER OF COUNTER MOUNTED SINK FIXTURES.

1. SEALANT COLOR TO MATCH COUNTERTOP OR SINK COLOR.

C. SEAL WINDOW SILLS TO WALL AND WINDOW FRAMES TO SEAL JOINTS.

1. SEALANT COLOR TO MATCH COLOR OF SILL MATERIAL SPECIFIED.

16. EDGES OF RAW FIBERBOARD TO BE SEALED WITH POLYURETHANE BEFORE ASSEMBLY.

17. PROVIDE ACCESS PANELS TO WIRING AS REQUIRED.

18. ALL CASEWORK EXPOSED SURFACES ARE TO RECEIVE PLASTIC LAMINATE PL-1. UNO

INTEGRAL OR SEPARATE SUB-BASE

ANCHOR BASE AND TALL

CABINETS

TO STUDS AT FLOOR

BLOCKING AT TOP OF BASE CABINETS

INTEGRAL BACKSPLASH SCRIBE TO WALL

BLOCKING AT CENTER OF TALL CABINETS

2" TASK LIGHT VALANCE (LV) WHERE

INDICATED ON ELEVATIONS

BLOCKING AT BOTTOM OF WALL CABINETS

TALL CABINET

BLOCKING AT TOP OF WALL AND TALL CABINETS

SOFFITS WHERE INDICATED ON ELEVATIONS

SOFFIT SEE DETAIL 9/AI101 FOR

TYPICAL

GYP. BOARD SOFFIT

CONT. 2x6

BLOCKING

4' -0

C A

B

IN

E T

H E

IG

H

T

7' -0

1/

2"

4"

W O

R K

S U

R

FA

C E

H E

IG

H

T

IN501

PLASTIC

LAMINATE

CASEWORK

GWB SOFFIT

PLASTIC

LAMINATE

SCRIBE ANGLE

1"

2"

CONT. AS

REQ'D.

MTL. STUDS @ 16" O.C. MAX.

2 X #12 S.M.S @ EA. @ EA. STUD

20 GA. SOLID, STUD-WALL RUNNER

TRACK PROVIDE ADDITIONAL

HORIZONTAL TRACKS AS REQUIRED

WALL

COUNTERTOP

CABINET BELOW

BACK SPLASH

1"

1"

2"

R 0

2"

4"

Work Surface Supports

A&M HARDWARE NO.'S

SIZE NO.

8"x 12" AH-812BLK FOR 9"-15" DEEP TOP

15"x 21" AH-1521BLK FOR 16"-24" DEEP TOP

18"x 24" AH-1824BLK FOR 23"-29" DEEP TOP

24"x 29" AH-2429BLK FOR 30"-36" DEEP TOP

BRACKET TO BE CONSTRUCTED OF 1/8" STEEL,

WITH TEXTURED POWDER COAT FINISH.

1 1/2" FORMS WITH 1/4" MOUNTING HOLES

LOAD LIMIT 1000 LBS PER PAIR OF BRACKETS.

COLOR : BLACK

OPTIONAL COLORS: WHITE, ALSO FOLKSTONE GRAY FINISH;

VERIFY COLOR WITH PROJECT INTERIOR DESIGNER, BEFORE

ORDERING

"BAER Supply company" 1.800.289.2237 www.baersupply.com

BACKSPLASH WHERE INDICATED SCRIBE TO WALL

WOOD BLOCKING EXTENDED PAST

SEE TYPICAL WALL BACKING PLATE DETAIL

COUNTERTOP WORK SURFACE

WIRE RUN AREA

SEE FLOOR PLAN

FOR WALL TYPE

CORNER GUARD W/

CONTINUOUS RETAINER ATTACHED

TO METAL STUDS, TYP.

CG-1

ADD AN ADDITIONAL LAYER OF GWB AT RATED WALLS

TRUE

KEY PLAN

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMP

321 4 5 6 7 8 9 10

Alesia Architecture P.C.

3705 North 200th Street Elkhorn, Nebraska 68022 Phone: (402) 291-6941 o n e e ig h th i n c h o n e f o o t th re e i n c h e s o n e f o o t o n e a n d o n e h a lf i n c h e s o n e f o o t o n e i n c h o n e f o o t th re e q u a rt e rs i n c h o n e f o o t o n e h a lf i n c h o n e f o o t th re e e ig h th s i n c h o n e f o o t o n e q u a rt e r in c h o n e f o o t

CONSTRUCTION

DOCUMENTS

PREPARE SITE FOR CHOICE

DINING EQUIPMENT

589A7-23-305

5500 E KELLOGG AVE, WICHITA, KS

A

B

C

D

E

F

A u to d e s k D o c s /1

A -2

-3

P re p a re

S it e f o r C h o ic e

D in in g /5

A -2

-3

.B

.A rc h

R

-E x is ti n g

.r v t

/2

/2

:4

:3

P

M

IN501

CASEWORK SECTIONS

RJO JJG05/17/2024

1 1/2" = 1'-0"1

BASE CABINET SECTION

1 1/2" = 1'-0"2

BASE CABINET SECTION

1 1/2" = 1'-0"3

UPPER CABINET SECTION

1 1/2" = 1'-0"7

CASEWORK GROUNDING

1 1/2" = 1'-0"4

CASEWORK SOFFIT

1 1/2" = 1'-0"5

TYP. WALL BACKING DETAILS

1 1/2" = 1'-0"6

CASEWORK COUNTERTOP EDGE

1" = 1'-0"8

CASEWORK SUPPORT BRACKET

3" = 1'-0"9

CORNER GUARDS

Mark Revisions: Date:

A

R C H I T E

C

T

S T A T E

O F N E B

R A S K A

05/17/2024

RICHARD

JOSEPH

J

J

W ,1

J

F

J

SD

J J

J J

W,1

J

F

SD

R E

X

2 2

T

S ,D a a

T

T

J

F A

C P

G G

G G G

J

DN

DN

S S S S S S S S S S S S

S S

S

SS

S S

S S

S S

S

S S S S S S S

QH901

QH901

SUPERVISORS

OFFICE

MULTIPURPOSE

ROOM

STAFF

BREAKROOM

STAFF

WORKROOM

KITCHEN

MANAGER

107A

HOT

PRODUCTION/TRAY

ASSEMBLY

LINE

COLD FOOD

PREP

103A

R0008 R0007

R0006

R0003

R0010

U0004

R0009

R0014

R0015

U0006U0006

U0002

U0002A

R0017

R0018

R0025

U0003U0001

U0009

U0007

U0005

QH901 5

R0021

U0010

R0029

U0010

R0030

U0007

R0002

QH901

R0032

R0033

R0034

U0011 U0011

R0012

R0031

R0022

OFFICE

100B

STAFF

TOILET

105A

KITCHEN/DIETETICS

KITCHEN/DIETETICS

KITCHEN/DIETETICS

STAIR

1STAIR

TELEPHONE

CLOSET

CONFERENCE

ROOM

STORAGE

GENERAL

105C

ELEVATOR

1ELEV

CORRIDOR

1CORR-DIET

CORRIDOR

1CORR

DISH

WASHER

WALK-IN

REFRIGERATOR

KITCHEN/DIETETICS

104A

KITCHEN/DIETETICS

FREEZER

TRUE

KEY PLAN

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMP

321 4 5 6 7 8 9 10

Alesia Architecture P.C.

3705 North 200th Street Elkhorn, Nebraska 68022 Phone: (402) 291-6941 o n e e ig h th i n c h o n e f o o t th re e i n c h e s o n e f o o t o n e a n d o n e h a lf i n c h e s o n e f o o t o n e i n c h o n e f o o t th re e q u a rt e rs i n c h o n e f o o t o n e h a lf i n c h o n e f o o t th re e e ig h th s i n c h o n e f o o t o n e q u a rt e r in c h o n e f o o t

CONSTRUCTION

DOCUMENTS

PREPARE SITE FOR CHOICE

DINING EQUIPMENT

589A7-23-305

5500 E KELLOGG AVE, WICHITA, KS

A

B

C

D

E

F

A u to d e s k D o c s /1

A -2

-3

P re p a re

S it e f o r C h o ic e

D in in g /5

A -2

-3

.B

.A rc h

R

-E x is ti n g

.r v t

/2

/2

:4

:2

P

M

QH101

FIRST FLOOR - EQUIPMENT PLAN

RJO JJG05/17/2024

GENERAL NOTES

1 ALL NEW CONSTRUCTION IS INDICATED BOLD OR FULL TONE.

2 ALL INTERIOR WALLS WILL BE TYPE "A" CONSTRUCTION UNLESS OTHERWISE INDICATED. REFER TO

SHEET A-002.

3 ALL INTERIOR WALLS WILL BE TYPE "A" CONSTRUCTION UNLESS OTHERWISE INDICATED. REFER TO

SHEET A-002

4 ALL METAL STUD AND GYPSUM WALLBOARD PARTITIONS ARE DIMENSIONED TO THE OUTSIDE FACE AND

TO COLUMN GRID UNLESS OTHERWISE NOTED.

5 WHEN WALL PARTITIONS OF DIFFERENT FIRE RATING INTERSECT, THE HIGHEST RATED PARTITION TAKES

PRECEDENT. MAINTAIN RATING BEHIND FIRE EXTINGUISHER CABINETS, ETC.

6 CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS PRIOR TO CONSTRUCTION.

7 REFER TO THE Q SERIES FOR ARCHITECTURAL EQUIPMENT NUMBERS.

8 REFER TO SHEET A-003 FOR TYPICAL BACKING DETAIL WITHIN INTERIOR WALL PARTITION, HANDRAILS, CUBICAL CURTAIN TRACKS, CORNER GUARDS ETC.

9 ALL EXISTING TO REMAIN CEILING AND WALL GRILLES, DIFFUSERS AND LIGHTS ETC. TO BE CLEANED.

10 VERIFY THAT THE EXISTING WALLS REQUIRING FIRE RATING ARE MAINTAINED, REPAIRED AND EXTENDED

TO STRUCTURE.

11 ALL CORRIDOR WALLS ARE REQUIRED TO BE SMOKE TIGHT, WHETHER THEY ARE FIRE RATED OR NOT.

REPAIR AND EXTEND AT LEAST THE CORRIDOR SIDE OF NON-FIRE RATED CORRIDOR WALLS TO

STRUCTURE, UNLESS NOTED OTHERWISE NOTED. SEE PARTITION TYPES SHEET.

12 REFER TO LIFE SAFETY PLANS FOR LOCATION OF REQUIRED FIRE WALLS.

13 REFER TO SPECIFCATIONS FOR EXPANSION JOINT ASSEMBLIES. PROVIDE FIRE RATED EXPANSION

JOINTS IN RATED FIRE WALLS, REFER TO LIFE SAFETY SERIES FOR FIRE RATINGS.

14 ALL FURNITURE SHOWN HALF TONE WILL BE OWNER FURNISHED AND OWNER INSTALLED.

1/4" = 1'-0"1

FIRST FLOOR - EQUIPMENT FLOOR PLAN

EQUIPMENT SCHEDULE COMPACT

EQPM CODE DESCRIPTION MANUFACTURER

R0002 Prep Table, Stainless Steel Regency

R0003 Combi Oven SCC - Double Stacked Southbend

R0006 Griddle - Gas Countertop with Manual Controls and 2 Drawer Refrigerated Chef Base VULCAN

R0007 Combi Oven CONVOTHERM

R0008 Combi Oven Alto-Shaam

R0009 3-DOOR FRIDGE TRAULSEN

R0010 Freezer - Glass Door Reach-In Beverage-Air

R0012 Single Compartment Stainless Steel Sink -

R0014 Blender Avamix

R0015 12" Manual Gravity Feed Meat Slicer HOBART

R0017 Super Adjustable Chrome 4 Tier Mobile Shelving Unit with Rubber Casters - 24" x 48" x 69" Metro

R0018 20 Pan End Load Nesting Bun/Sheet Pan Rack Regency

R0021 Legacy Tabletop mixer with a 12 quart capacity stainless steel bowl. HOBART

R0022 Smart Therm Induction Charger DINEX

R0024 Work Table Elkay SSP, LLC

R0025 3424-88 Three Shelf Utility Cart Rubbermaid Commercial Products

R0026 Work Table Elkay SSP, LLC

R0027 Dispenser, Paper Towel, Sensor, Hands Free BRADLEY CORPORATION

R0029 NG-300 Coffee System Folgers

R0030 High Speed Oven MERRYCHEF

R0031 Prep Table, Stainless Steel Regency

R0032 Prep Table, Stainless Steel Regency

R0033 Prep Table, Stainless Steel Regency

R0034 Equipment Stand, stainless steel Regency

U0001 THREE PAN OPEN WELL ELECTRIC STEAM TABLE Eagle Group

U0002 Prep Table, Stainless Steel Regency

U0002A Double Deck Overshelf 18" x 72" - SS Regency

U0003 Sandwich Prep Table Atosa

U0004 Stainless Steel Wall Mounted Hand Sink with Foot Pedal Faucet Eagle Group

U0005 Commercial Gas Range and 2 Standard Ovens Southbend

U0006 18 Gauge Stainless Steel 12" x 48" Solid Wall Shelf REGENCY

U0007 Strip Warmer with Toggle Controls HATCO

U0009 Prep Table, Stainless Steel Regency

U0010 Refrigerator with Worktop True

U0011 Double Deck Overshelf 18" x 48" Regency

Mark Revisions: Date:

A

R C H I T E

C

T

S T A T E

O F N E B

R A S K A

05/17/2024

RICHARD

JOSEPH

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMP

321 4 5 6 7 8 9 10

Alesia Architecture P.C.

3705 North 200th Street Elkhorn, Nebraska 68022 Phone: (402) 291-6941 o n e e ig h th i n c h o n e f o o t th re e i n c h e s o n e f o o t o n e a n d o n e h a lf i n c h e s o n e f o o t o n e i n c h o n e f o o t th re e q u a rt e rs i n c h o n e f o o t o n e h a lf i n c h o n e f o o t th re e e ig h th s i n c h o n e f o o t o n e q u a rt e r in c h o n e f o o t

CONSTRUCTION

DOCUMENTS

PREPARE SITE FOR CHOICE

DINING EQUIPMENT

589A7-23-305

5500 E KELLOGG AVE, WICHITA, KS

A

B

C

D

E

F

A u to d e s k D o c s /1

A -2

-3

P re p a re

S it e f o r C h o ic e

D in in g /5

A -2

-3

.B

.A rc h

R

-E x is ti n g

.r v t

/2

/2

:4

:1

P

M

QH601

EQUIPMENT SCHEDULE

RJO JJG05/17/2024

Equipment Schedule

EQPM CODE DESCRIPTION MANUFACTURER MODEL COUNT URL

R0002 Prep Table, Stainless Steel Regency Equipment Stand 2 https://www.webstaurantstore.com/regency-30-x-72-all-18-gauge-430-stainless-steel-commercial-work-table-with-undershelf/600TA3072S.html

R0003 Combi Oven SCC - Double Stacked Southbend GS/25SC 2 https://www.webstaurantstore.com/rational-selfcookingcenter-5-senses-model-62-b628206-19e-natural-gas-single-deck-combi-oven-208-240v/645B628206HN.html

R0006 Griddle - Gas Countertop with Manual Controls and 2 Drawer Refrigerated Chef Base VULCAN 901VGT48CB48 1 https://www.webstaurantstore.com/vcrg48-t1-48-tg-with-48-avantco-refrig-chef-bse/901VGT48CB48.html

R0007 Combi Oven CONVOTHERM C4ED6.20EB-N 208/240/3 1…

This is the start of the file's text. The full file is on GovTribe.