5877_Influent_New_Plant_FlowMeter_SWWRF_(004).pdf
PDF 128 KB Posted
- Attached to
- Panametrics AT600 Ultrasonic FlowMeter (Qty 5)
- Solicitation number
- Quote- 26 - 188
- Issued by
- Pinellas County, Florida
About this file
This is a vendor quote document prepared for the City of St. Petersburg, Florida, Department of Public Utilities for the supply of a Panametrics AT600 Ultrasonic FlowMeter to the Southwest Water Reclamation Facility (SWWRF). The quote, dated January 23, 2026, and identified as Quote #5877, provides pricing for one unit of the specified flowmeter model AT6-C1-CR05-48IN-4-1AAT01E-0, featuring a clamp-on ultrasonic transducer system with 0.5 MHz frequency, 100-foot cable length, and both analog (4-20mA) and digital output capabilities. The equipment is designed for use on 12 to 48-inch pipes with input power ranging from 85 to 265 VAC. Delivery to the SWWRF location is subject to a four to six-week lead time, with all terms offered on a net 30 payment basis and FOB shipping arrangement.
The quote establishes a unit price of $6,932.40 for the flowmeter equipment with an additional freight charge of $222.00, resulting in a total quoted value of $7,154.40 per unit. This reference pricing is applicable to the City's solicitation for five flowmeters, suggesting a potential total procurement value between $35,772 and $40,000 depending on final competitive submissions and delivery requirements. The City has established minimum insurance requirements of one million dollars in commercial general liability and commercial automobile liability, with a mandatory twelve-month warranty on all goods following acceptance. All submittals are required through the OpenGov Procurement portal with a deadline of April 3, 2026, at 12:00 p.m., with vendors obligated to meet Florida Department of State registration requirements and E-Verify compliance under Florida Statute 448.095.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Panametrics_AT600_Ultrasonic_FlowMeter_(Qty_5).pdf | ||
| 5877_Influent_New_Plant_FlowMeter_SWWRF_(004).pdf | ||
| Light_Construction_Agreement.docx | DOCX document | |
| Quote_Addendum.docx | DOCX document | |
| Subcontractor_Utilization_Plan.docx | DOCX document | |
| Subcontractor_Summary_-_Sheltered_.xlsx | XLSX spreadsheet | |
| Performance_&_Payment_Bond_.DOCX | DOCX document | |
| Public_Construction_Bond.docx | DOCX document | |
| Subcontractor_Summary_Spreadsheet.xlsx | XLSX spreadsheet |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Quote
Date
1/23/2026
Quote #
Name / Address
City of St. Petersburg Public Utilities Attn: Accounts Payable P.O. Box 1257 St. Petersburg, FL 33713
Ship To
Influent New Plant SWWRF
P.O. No. Terms Project
Approval Signature Total
Net 30 5877 Influent New Plant FlowMeter SWWRF
Description Qty Cost Total
AT6-C1-CR05-48IN-4-1AAT01E-0
Panametrics AT600 Ultrasonic FlowMeter Transducers: C-RS, 0.5MHz, IP66 (12 to 48in. Pipes) Cable Length: 100ft (30m) Input Power: 85 to 265 VAC Analog & Digital Output 4-20mA Analog Output Only Discrete Output One alarm Contact and One Totalizer (Pulse) Output
1 6,932.40 6,932.40
Freight 1 222.00 222.00
Lead Time: 4 - 6 Weeks FOB
$7,154.40
File details come from the government source that posted it. Updated .