586-22-102 DRAWINGS PC BLUE.pdf
PDF 36 MB Posted
- Attached to
- Y1DZ | 586-22-102 | Renovate PC Blue for PACT - Women's Health Clinic | SOLICITATION- AMEND 005
- Solicitation number
- 36C25626R0012
About this file
This document is an architectural and structural set of design drawings for a renovation project at the G.V. (Sonny) Montgomery VA Medical Center in Jackson, Mississippi. The project involves renovating approximately 6,850 square feet of space in the PC Blue area for a Women's Health PACT (Patient-Aligned Care Team) Clinic, with a total project duration of 540 calendar days. The renovation includes comprehensive architectural, mechanical, electrical, plumbing, and structural work across multiple floor levels, with specific focus on creating new medical spaces including exam rooms, reception areas, staff spaces, and a mechanical penthouse.
The solicitation is exclusively set aside for Service-Disabled Veteran-Owned Small Businesses (SDVOSB), with a requirement that at least 15% of contract personnel costs be spent on employees of eligible SDVOSB concerns. The project involves completely renovating the existing space while maintaining medical center operations, adhering to JCAHO, NFPA, ICARA, OSHA, and life safety requirements. Key design elements include new partitions, ceiling systems, medical equipment spaces, fire-rated assemblies, and specialized medical room configurations. The anticipated solicitation release date is 12/12/2025, with a firm-fixed price contract expected to be awarded following a Request for Proposals (RFP) process.
View the file
Other files
Show all 22
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
GENERAL NOTES APPLICABLE TO ALL DRAWINGS FOR
THIS PROJECT
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
ALL NOTES ON ALL DRAWINGS PERTAIN TO THE CONTRACTOR.
NO SMOKING IN AREAS OTHER THAN OFFICIALLY MARKED AS SMOKING AREA WILL BE PERMITTED ON VA
PREMISES.
THE CONTRACTOR SHALL BE PREPARED TO STOP ANY WORK AND CLEAR UP THE WORK AREA IF SO ASKED
IN MEDICAL SITUATIONS REQUIRING SUCH ACTION.
ALL TOOLS AND MATERIAL USED IN THE PROJECT SHALL BE PROPERLY SECURED AT ALL TIMES BY THE CONTRACTOR TO REDUCE THE POSSIBILITY OF ANY OF THESE TOOLS BEING A HAZARD TO PATIENTS, VISITORS OR STAFF.
ALL VA PROPERTY THAT IS NOT PERMANENTLY REMOVED FROM VA PREMISES UNDER THIS PROJECT WHICH IS DAMAGED BY CONSTRUCTION OF THIS PROJECT, SHALL BE REPLACED OR REPAIRED TO MATCH OR
EXCEED THE QUALITY THAT EXISTED BEFORE THE DAMAGE.
THE CONTRACTOR, AT HIS EXPENSE WILL BE RESPONSIBLE FOR TRAINING EACH MEMBER OF HIS WORK FORCE ON VA POLICIES FOR ON-SITE WORK BEFORE ANY MEMBER WILL BE ALLOWED TO PERFORM WORK ON VA PREMISES. BACKGROUND CHECKS WILL BE REQUIRED ON ALL EMPLOYEES AND ALL EMPLOYEES
MUST BE BADGED IN ACCORDANCE WITH VA POLICE DEPARTMENT AND THE VA.
ABSOLUTELY NO VA TOOLS, MATERIALS OR EQUIPMENT WILL BE LOANED OR GIVEN BY THE VA TO ANY
MEMBER OF THE CONTRACTOR’S WORK FORCE AT ANY TIME.
ANY SMOKE DETECTORS HAVING ANY POTENTIAL FOR EXPOSURE TO CONSTRUCTION SMOKE, DUST AND DEBRIS SHALL BE SUITABLY ATTENDED TO IN ORDER TO PREVENT ACCIDENTAL ALARM. ALL SUCH ACTION MUST BE FIRST COORDINATED AND CLEARED WITH THE COR AND THE VA SAFETY OFFICER. ALL FIRE ALARM DEVICES SHALL BE ACTIVE WHEN CONTRACTOR’S FORCES ARE VACANT FROM ANY AREA AT ANY
TIME.
CONTRACTOR SHALL COORDINATE WITH THE COR AND CONTRACTING OFFICER.
SEE SPECIFICATION SECTION 01 35 26 SAFETY REQUIREMENTS.
GENERAL HOURS OF WORK SHALL BE RESTRICTED FROM 0730 TO 1600 MONDAY THRU FRIDAY EXCEPT FEDERAL HOLIDAYS. CONTRACTOR MAY SUBMIT A REQUEST FOR OFF-HOUR WORK A MINIMUM 72 HOURS IN ADVANCE. APPROVAL IS AT SOLE DISCRETION OF THE VA. WHEN SOME NIGHT/WEEKEND WORK IS
REQUIRED, COORDINATE WITH PHASING PLAN SHEET A101.
VA APPROVAL
DEPARTMENT SIGNATURES
MEDICAL CENTER DIRECTOR
MEDICAL CENTER ASSOCIATE DIRECTOR
CHIEF OF STAFF
ASSOCIATE DIRECTOR OF PATIENT CARE
DEPUTY CHIEF OF STAFF /
PHYSICAL MEDICINE & REHAB
SERVICE REPRESENTATIVE
SAFETY OFFICE
PROJECT MANAGER
INFECTION PREVENTION
ENGINEERING CHIEF
DEPARTMENT OF VETERANS AFFAIRS
G.V. (SONNY) MONTGOMERY VAMC
JACKSON, MS
AD100 ARCHITECTURAL DEMO FLOOR PLAN & RCP
AD101 ARCHITECTURAL DEMO PLANS AND RCP
A101 FLOOR PLAN - 1ST & 2ND
A102 A103
REFLECTED CEILING PLANS
ENLARGED FLOOR PLANS & INTERIOR ELEVATIONS
A201 PENTHOUSE ELEVATIONS, SECTIONS & ROOF PLAN
A502 SIGNAGE, MILLWORK DETAILS & MISCELLANEOUS DETAILS
A601 OPENING SCHEDULES & DETAILED DOOR SECTIONS
G001 COVER SHEET
G002 PROJECT DATA
LS101 LIFE SAFETY PLAN
Project Location
INDEX OF DRAWINGS
ELECTRICAL
ARCHITECTURAL
PROJECT NO. 586-22-102
RENOVATION OF PC BLUE FOR PACT
VICINITY MAP
MD101 BASEMENT FLOOR PLAN - CONTROLS DEMOLITION
MD102 FIRST FLOOR PLAN - HVAC - DEMOLITION
MD103 FIRST FLOOR PLAN - EXHAUST AND HEATING WATER PIPING - DEMOLITION
MD104 FIRST FLOOR PLAN - LARGE SCALE CHILLED WATER - DEMOLITION
MD105 FIRST FLOOR PLAN - LARGE SCALE MECHANICAL ROOM CHILLED WATER SCHEMATIC - DEMOLITION
MD106 FIRST FLOOR PLAN - LARGE SCALE HEATING WATER - DEMOLITION
MD107 FIRST FLOOR PLAN - LARGE SCALE MECHANICAL ROOM HEATING WATER SCHEMATIC - DEMOLITION
MD108 FIRST FLOOR PLAN - LARGE SCALE STEAM PIPING - DEMOLITION
MD109 FIRST FLOOR PLAN - LARGE SCALE MECHANICAL ROOM STEAM PIPING SCHEMATIC - DEMOLITION
MH001 MECHANICAL SYMBOLS AND ABBREVIATIONS
MH002 MECHANICAL NOTES
MH101 BASEMENT FLOOR PLAN - CONTROLS - NEW WORK
MH102 FIRST FLOOR PLAN - HVAC - NEW WORK
MH103 FIRST FLOOR PLAN - HEATING & CHILLED WATER - NEW WORK
MH104 FIRST FLOOR PLAN - EXHAUST - NEW WORK
MH105 FIRST FLOOR PLAN - LARGE SCALE PENTHOUSE HVAC - NEW WORK
MH106 FIRST FLOOR PLAN - LARGE SCALE MECHANICAL ROOM HEATING WATER PIPING - NEW WORK
MH107 FIRST FLOOR PLAN - LARGE SCALE MECHANICAL ROOM STEAM PIPING - NEW WORK
MH108 FIRST FLOOR PLAN - LARGE SCALE PENTHOUSE HYDRONIC PIPING - NEW WORK
CAMPUS MAP
Project Location
E000 ELECTRICAL LEGEND AND NOTES
E001 ELECTRICAL DETAILS
E002 ELECTRICAL DETAILS
E101 ELECTRICAL DEMOLITION PLAN - BASEMENT
E102 ELECTRICAL DEMOLITION PLAN - FIRST FLOOR
E201 NEW LIGHTING PLAN - FIRST FLOOR
E202 NEW POWER AND COMM. PLAN - FIRST FLOOR
E203 NEW FIRE ALARM AND MECH SYSTEMS PLAN - BASEMENT
E204 NEW FIRE ALARM AND MECH SYSTEMS PLAN - FIRST FLOOR
E205 NEW ELECTRICAL PLAN - MECH. PENTHOUSE
G001
COVER SHEET
S100 STRUCTURAL GENERAL NOTES
S101 FLOOR PLAN - 1ST & 2ND
S102 DETAILS
STRUCTURAL
MH301 MECHANICAL DETAILS
MH302 MECHANICAL DETAILS
MH303 MECHANICAL DETAILS
MH304 MECHANICAL DETAILS
MH305 MECHANICAL DETAILS
MH306 MECHANICAL DETAILS
MH307 MECHANICAL DETAILS
MH308 MECHANICAL DETAILS
MH401 MECHANICAL DETAILS
MH402 MECHANICAL DETAILS
MH403 MECHANICAL DETAILS
MH501 MECHANICAL DETAILS
MH502 MECHANICAL DETAILS
MH503 MECHANICAL DETAILS
MECHANICAL
PD101 FIRST FLOOR PLAN - PLUMBING WASTE - DEMOLITION
PD102 FIRST FLOOR PLAN - PLUMBING SUPPLY - DEMOLITION
PL001 PLUMBING SYMBOLS, NOTES, & ABBREVIATIONS
PL101 FIRST FLOOR PLAN - PLUMBING WASTE - NEW WORK
PL102 FIRST FLOOR PLAN - PLUMBING SUPPLY - NEW WORK
PL103 FIRST FLOOR PLAN - FIRE PROTECTION - NEW WORK
PL301 PLUMBING DETAILS & SCHEDULES
PLUMBING
PD103 FIRST FLOOR PLAN - FIRE PROTECTION - DEMOLITION
PD104 FIRST FLOOR PLAN - MEDICAL GAS - DEMOLITION
AD102
LS102 LIFE SAFETY PLAN - OVERALL FIRST LEVEL
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Consultant:
5190 Canal Boulevard, Suite 201 New Orleans, LA 70124 (504)835-8013
LACHIN
Architects, apc
Architecture . Planning . Project Management
RENOVATION OF PC BLUE FOR
WOMENS HEALTH
1500 E. Woodrow Wilson Dr. Jackson, MS
586-22-102
2/20/2025 MGL TAC
FINAL SUBMISSION
FULLY SPRINKLERED
Revisions: Date:
A202 PENTHOUSE DETAILS
WALL TYPES - SELECTIVE DEMOLITION
MECHANICAL CON'T.
S103 DETAILS
A100 FIRST FLOOR PHASING PLAN
A104
ENLARGED FLOOR PLANS & INTERIOR ELEVATIONS
E301 PANEL BOARD SCHEDULES
A602 ROOM FINISH SCHEDULE & PARTITION TYPES
A105
ENLARGED FLOOR PLANS & INTERIOR ELEVATIONS
FIRST FLOOR SIGNAGE PLAN
A106
A503 MILLWORK DETAILS
PD105 FIRST FLOOR PLAN - LARGE SCALE STORM WATER - DEMO
PL104 LARGE SCALE STORM WATER - NEW WORK
PL401 PLUMBING SCHEDULES
AFF ABOVE FINISHED FLOOR
ACT ACOUSTICAL CEILING TILE
ALUM ALUMINUM
BD BOARD
BOT BOTTOM
BUR BUILT-UP ROOFING
CIP CAST-IN-PLACE
CEM CEMENT
CTR CENTER
CL CENTER LINE
CT CERAMIC TILE
CFCI CONTRACTOR FURNISHED, CONTRACTOR INSTALLED
CO CLEANOUT, CASED OPENING
COL COLUMN
CONC CONCRETE
COR CONTRACTING OFFICER OF RECORD
CJ CONTROL JOINT
DET DETAIL
DIA DIAMETER
DIM DIMENSION
DR DOOR
DS DOWNSPOUT
EWC ELECTRIC WATER COOLER
EQ EQUAL
EXP EXPANSION
EJ EXPANSION JOINT
FRP FIBER REINFORCED POLYESTER
FIN FLR FINISH FLOOR
FE FIRE EXTINGUISHER
FD FLOOR DRAIN
GA GAUGE
GALV GALVANIZED
GB GRAB BAR
GYP GYPSUM
HVAC HEATING, VENTILATING & AIR CONDITIONING
HEPA HIGH EFFICIENCY PARTICULATE AIR
HM HOLLOW METAL
INT INTERIOR
LAM LAMINATE
LAV LAVATORY
MO MASONRY OPENING
MECH MECHANICAL
MTL METAL
MOD BIT MODIFIED BITUMEN
MS MOP SINK
NIC NOT IN CONTRACT
NTS NOT TO SCALE
OC ON CENTERS
OPP OPPOSITE
O/O OUT TO OUT
OA OVERALL
OH OVERHANG
PT PAINT
PNL PANEL
PTD PAPER TOWEL DISPENSER
PLAS PLASTER
PLAM PLASTIC LAMINATE
PLBG PLUMBING
PLYWD PLYWOOD
PL PROPERTY LINE
QT QUARRY TILE
RA RETURN AIR
REV REVISION
RTU ROOF TOP UNIT
RO ROUGH OPENING
SAB SOUND ATTENUATION BATTS
SND SANITARY NAPKIN DISPENSER
SJ SCORED JOINT
SS SERVICE SINK, STAINLESS STEEL
SIM SIMILAR
SD SOAP DISPENSER
SC SOLID CORE
TER TERRAZZO
TPD TOILET PAPER DISPENSER
TO_ TOP OF_
UNO UNLESS NOTED OTHERWISE
UR URINAL
VFCI VA FURNISHED, CONTRACTOR INSTALLED
VFVI VA FURNISHED, VA INSTALLED
VAV VARIABLE AIR VOLUME
VTR VENT THROUGH ROOF
VCT VINYL COMPOSITION TILE
WC WATER CLOSET
WR WEATHER RESISTANT
WD WOOD
2010: ADA STANDARDS FOR ACCESSIBLE DESIGN.
OCCUPATIONAL SAFETY AND HEALTH STANDARDS, U.S. DEPARTMENT OF LABOR
(OSHA): 29 CFR, PART 1926, AS AMENDED, INCLUDING FINAL RULE.
2023: NFPA 241, CONSTRUCTION, ALTERATION AND DEMOLITION OPERATIONS.
2018: INTERNATIONAL BUILDING CODE, NO LOCAL AMENDMENTS.
2022: NFPA 70, NATIONAL ELECTRICAL CODE.
2017: VA BARRIER FREE DESIGN STANDARD REV. 11/1/18
2018: IPC INTERNATIONAL PLUMBING CODE, NO LOCAL AMENDMENTS.
2018: IMC INTERNATIONAL MECHANICAL CODE, NO LOCAL AMENDMENTS.
ICC / ANSI 117.1 - 2009 AMERICAN NATIONAL STANDARD FOR ACCESSIBLE AND
USEABLE BUILDINGS AND FACILITIES.
2024: NFPA 101, LIFE SAFETY CODE FOR LOCAL JURISDICTION COMPLIANCE.
2024: NFPA 101, LIFE SAFETY CODE FOR FEDERAL CERTIFICATION. *(COMPLY WITH THE
MOST RESTRICTIVE REQUIREMENTS IF THESE TWO NFPA 101 STANDARDS
CONFLICT).
2024: NFPA 99, HEALTH CARE FACILITIES.
2018: GUIDELINES FOR DESIGN AND CONSTRUCTION OF HEALTH CARE FACILITIES,
FACILITIES GUIDELINES INSTITUTE.
JOINT COMMISSION FOR ACCREDITATION OF HEALTHCARE ORGANIZATIONS
(JCAHO), STANDARD EC5.50, INTERIM LIFE SAFETY MEASURES (ILSM), AS
PUBLISHED IN THE COMPREHENSIVE ACCREDITATION MANUAL FOR HOSPITALS:
THE OFFICIAL HANDBOOK (CAMH), 2004 EDITION.
2022: NFPA 13, STANDARD FOR THE INSTALLATION OF SPRINKLER SYSTEMS.
2022: NFPA 72, NATIONAL FIRE ALARM AND SIGNALING CODE.
FIRE PROTECTION OFFICE OF SAFETY, HEALTH AND ENVIRONMENTAL
COMPLIANCE (10NA8), 7th EDITION, Dec. 2015
2023: FIRE PROTECTION DESIGN MANUAL, Ninth Edition
GENERAL NOTES
A. DRAWINGS AND SPECIFICATIONS ARE INTENDED TO BE
COMPLEMENTARY. SPECIFIC INFORMATION MAY BE FOUND IN
EITHER OR BOTH.
B. CONTRACTOR TO VISIT THE SITE PRIOR TO BIDDING AND
BECOME FAMILIAR WITH ALL ASPECTS OF THE WORK. FAILURE
TO INSPECT THE SITE OR FULLY ACQUAINT HIMSELF WITH THE
PLANS AND SPECIFICATIONS PRIOR TO BIDDING WILL NOT
RELIEVE THE CONTRACTOR OF PERFORMANCE OF ANY OF THE
WORK REQUIRED BY EXISTING CONDITIONS OR THE INTENT OF
THE CONTRACT DOCUMENTS. BID SUBMITTAL SHALL REFLECT
ANY EXTRANEOUS CONDITIONS THAT MAY OCCUR.
C. LAYOUT OF WORK
1. EXERCISE PROPER PRECAUTION TO VERIFY ALL EXISTING
CONDITIONS AND LAYOUT OF THE WORK. CONTRACTOR TO
NOTIFY THE CONTRACTING OFFICER OF ANY DISCREPANCIES
IMMEDIATELY.
.2 CONTRACTOR IS RESPONSIBLE FOR ANY ERROR
RESULTING FROM FAILURE TO EXERCISE SUCH PRECAUTION.
SUCH ERROR WILL NOT BE CONSIDERED SUBSEQUENTLY AS A
BASIS FOR EXTRA COMPENSATION.
3. GC TO LAYOUT WORK AND BE RESPONSIBLE FOR ALL
LINES, MEASUREMENTS OF THE BUILDING AND OTHER WORK
EXECUTED UNDER CONTRACT.
4. SHOULD A CONTRACTOR FIND DISCREPANCIES IN, OR
OMISSIONS FROM THE DRAWINGS OR SPECIFICATIONS OR
SHOULD HE BE IN DOUBT AS TO THEIR MEANING, HE SHOULD
NOTIFY THE CONTRACTING OFFICER AT ONCE.
D. EXAMINATION
1. ANY DISCREPANCIES, ERRORS OR OMISSIONS
DISCOVERED IN THE CONTRACT DOCUMENTS BY THE
CONTRACTOR SHALL BE BROUGHT TO THE ATTENTION OF THE
CONTRACTING OFFICER BEFORE PROCEEDING WITH RELATED
WORK, OTHERWISE THE CORRECTION OF SUCH ITEMS IS THE
RESPONSIBILITY OF THE CONTRACTOR.
E. CODES AND STANDARDS
1. ALL WORK, MATERIALS AND INSTALLATION SHALL BE IN
STRICT ACCORDANCE'S WITH ALL VA AND NATIONAL BUILDING
CODES, LATEST EDITION.
2. DESIGN LOADS AND CODE RESTRICTIONS FOR ALL DESIGN
CONSIDERATIONS SHALL CONFORM TO THE VA AND NATIONAL
GOVERNING CODES.
F. DEMOLITION
1. THIS SECTION IS INCLUDED FOR GENERAL REFERENCE OF
DEMO WORK BY THE GENERAL CONTRACTOR.
2. DEMOLITION INCLUDES OBJECTS IDENTIFIED BY THE
CONTRACT DOCUMENTS AND SPECIFICATIONS.
3. ARRANGE WITH THE OWNER A CONVENIENT TIME TO
PERFORM DEMOLITION WORK.
4. THE CONTRACTOR SHALL REPAIR, RESTORE AND
REPLACE PORTIONS OF CONSTRUCTION WHERE INDICATED ON
DRAWINGS OR AS REQUIRED TO INSTALL THE WORK. ANY
PORTIONS OF THE CONSTRUCTION WHICH ARE CRACKED,
SPALLED, BROKEN, MISSING OR OUT OF LINE OR ADJUSTMENT,
MECHANICALLY OR STRUCTURALLY UNSOUND OR UNSAFE,
SHALL BE REMOVED, REPLACED, RESTORED OR
SATISFACTORILY REPAIRED.
5. REMOVE, PROTECT AND REINSTALL ALL ITEMS AFFECTED BY
CONSTRUCTION THAT ARE NOT INDICATED TO BE REMOVED
INCLUDING, BUT NOT LIMITED TO SPEAKERS, WIFI AND OTHER
EXISTING MISCELLANEOUS DEVICES.
G. ALL WORK SHALL BE PERFORMED IN CONFORMANCE WITH
APPLICABLE STANDARD SPECIFICATIONS. WORKMANSHIP AND
MAINTAINING STANDARDS OF QUALITY SHALL BE THE
RESPONSIBILITY OF THE GENERAL CONTRACTOR. THE
GENERAL CONTRACTOR SHALL PROVIDE ALL WORK SHOWN IN
THESE CONTRACT DOCUMENTS AND IS REQUIRED TO PROVIDE
A COMPLETE, FINISHED, FULLY OPERABLE INSTALLATION,
UNLESS OTHERWISE NOTED. IT IS THE RESPONSIBILITY OF THE
CONTRACTOR AND EACH OF THE SUBCONTRACTORS TO BE
ACQUAINTED WITH ALL PROJECT REQUIREMENTS AND BUILDING
STANDARDS REGARDLESS OF WHETHER THEY HAVE BEEN
SPECIFICALLY REFERENCED IN THE DOCUMENTS OR NOT.
I. CONTRACTOR SHALL COORDINATE WITH THE CONTRACTING
OFFICER THE SELECTION AND APPROVAL OF ALL SUBSTITUTED
ITEMS PRIOR TO SUBMISSIONS OF THE BID. IT IS EACH
CONTRACTOR'S RESPONSIBILITY TO ENSURE AND TO
DEMONSTRATE THAT ALL SUBSTITUTIONS USED IN THE WORK
COMPLY WITH THE CONTRACT DOCUMENTS. SHOULD A
SUBSTITUTED PRODUCT FAIL TO PERFORM FOR ANY REASON,
WHERE THE ORIGINALLY SPECIFIED PRODUCT WOULD HAVE
PERFORMED PROPERLY, THE CONTRACTOR SHALL PERFORM
ALL WORK NECESSARY TO INCORPORATE THE ORIGINALLY
SPECIFIED PRODUCT AT NO ADDITIONAL COST.
J. EACH SUBCONTRACTOR SHALL CHECK AND VERIFY PRIOR TO
BID, ALL PLANS, SPECIFICATIONS, EXISTING CONDITIONS AND
DIMENSIONS AT THE JOB SITE AND SHALL NOTIFY THE
CONTRACTING OFFICER OF ANY DISCREPANCIES IN OR
BETWEEN THE CONTRACT DOCUMENTS AND THE FIELD
CONDITIONS PRIOR TO COMMENCING THE WORK.
K. DO NOT TAKE SCALED MEASUREMENTS FROM THESE
DRAWINGS. CONSULT WITH THE COR FOR MISSING DIMENSIONS.
L. EACH CONTRACTOR SHALL ANALYZE THE CONTRACT
DOCUMENTS AND IMMEDIATELY REPORT ANY DISCREPANCIES
TO THE CONTRACTING OFFICER PRIOR TO BID. EACH
CONTRACTOR SHALL BE REQUIRED TO CORRECT ANY
DEFECTIVE WORK CAUSED BY WORK DONE AS A RESULT OF
INCONSISTENCIES OR DISCREPANCIES IN THE DRAWINGS WHEN
CLARIFICATION FROM THE CONTRACTING OFFICER HAS NOT
BEEN SOUGHT.
M. ARCHITECTURAL, PLUMBING, ELECTRICAL, MECHANICAL AND
ALL OTHER DOCUMENTS SHALL BE REVIEWED AND
COORDINATED BY THE CONTRACTOR. REPORT ANY
INCONSISTENCIES WITHIN THE DOCUMENTS TO THE
CONTRACTING OFFICER.
N. CONTRACTOR SHALL PROVIDE THE COR WITH A SET OF
REPRODUCIBLE AS-BUILT DOCUMENTS AND DVD AT THE
PROJECT CLOSE-OUT PER SPECIFICATIONS.
O. AS SCOPE AND PERFORMANCE DOCUMENTS, THE DRAWINGS
AND SPECIFICATIONS INDICATE THE MINIMUM WORK REQUIRED
FOR THE PERFORMANCE AND COMPLETION OF BUILDING
ASSEMBLIES. THE CONTRACTOR SHALL BE SOLELY
RESPONSIBLE FOR THE FABRICATION AND INSTALLATION OF ALL
MISCELLANEOUS METAL ITEMS INDICATED, DESCRIBED OR
IMPLIED ON ALL DRAWINGS. MISCELLANEOUS METAL ITEMS,
WITHIN OR REQUIRED TO SUPPORT AN ASSEMBLY, WHETHER
OR NOT ATTACHED TO THE STRUCTURE, ARE THE
RESPONSIBILITY OF THE GENERAL CONTRACTOR AND HIS
SUBCONTRACTORS WHETHER THEY ARE SHOWN OR NOT
SHOWN ON THE ARCHITECTURAL, STRUCTURAL, CIVIL,
MECHANICAL OR ELECTRICAL DRAWINGS. SUCH ASSEMBLIES
INCLUDE BUT ARE NOT LIMITED TO EXTERIOR AND INTERIOR
WALL, CEILING, PARTITION, ROOF, MECHANICAL AND
ELECTRICAL ASSEMBLIES AS WELL AS ALL SIMILAR
ASSEMBLIES. ANY MISCELLANEOUS METAL ITEMS INDICATED
ON THE ARCHITECTURAL DRAWINGS AND NOT SHOWN ON
STRUCTURAL DRAWINGS SHALL BE A MINIMUM OF L3x3x1/2", C7x9.8, 3/8" PLATE OR TS4x4x3/8" UNLESS OTHERWISE
APPROVED BY THE STRUCTURAL ENGINEER. STEEL BEAMS
SHOWN ON THE ARCHITECTURAL DRAWINGS BUT NOT ON THE
STRUCTURAL DRAWINGS SHALL BE ASSUMED TO BE A MEDIUM
WEIGHT BEAM CONNECTED FROM COLUMN TO COLUMN WITH A
SIZE CONSISTENT WITH THE SCALED HEIGHT OF THE BEAM.
P. ALL CONTRACTORS WORKING IN THE HOSPITAL WILL HAVE
TO GO THROUGH A BASIC BACKGROUND CHECK. THE PROCESS
WILL REQUIRE FINGERPRINTING AND APPROXIMATELY THREE
WEEKS OF PROCESSING TIME BEFORE WORKERS /
CONTRACTORS CAN ENTER THE PROJECT AREA.
NORTH ARROW
Room name
101ROOM TAG
EQUIPMENT TAG
COLUMN GRID TAG
LEVEL ANNOTATION
BUILDING SECTION
VIEW / DETAIL TITLE
PARTITION TAG
DOOR TAG
CENTERLINE
REVISION CLOUD
BREAK LINE
SPOT ELEVATION
ENLARGED PLAN / DETAIL REFERENCE
x'-x"
BUILDING ELEVATION
WALL SECTION
REVISION
INTERIOR ELEVATION
GLAZING TYPE TAG
SECTION / DETAIL
FLOOR LINES IN EXTERIOR ELEVATION; CENTER
PROPERTY LINE, BOUNDARY LINES
MATCH LINE
FX
BX
WX
WX
WX WXROOM FINISH TAG
FLOORWALL FINISH
BASE
FINISH MATERIAL TAG XX-##
PARTITION WITH CORNER GUARD
PARTITION WITH WALL GUARD
PARTITION WITH END CAP
PARTITION WITH ADDITIONAL BRACING
A203
A1
DRAWING BLOCK TITLE
SCALE: 1"=1'-0"
Name Elevation
A001
A
WOOD
WOOD FINISH
ALUMINUM
STEEL
EARTH
GYPSUM - PLASTER
MASONRY -
CONCRETE BLOCK
RIGID INSULATION
BATT INSULATION
PLYWOOD
CONCRETE
1.
2.
3.
4.
5.
6.
7.
8.
9.
THE RENOVATION OF PC BLUE TO PACT PROJECT INCLUDES RENOVATION OF
APPROXIMATELY 6,850 SQUARE FEET OF AREA WITHIN THE EXISTING VA MEDICAL
CENTER.
THE WORK GENERALLY INCLUDES BUT IS NOT LIMITED TO:
INSTALLATION OF TEMPORARY PARTITIONS, DOOR AND OTHER PROTECTIVE
MEASURES TO ISOLATE THE CONSTRUCTION AREA. PROVIDE NEGATIVE
PRESSURE FOR DUST CONTROL AND ACOUSTICAL SEPARATION SO AS NOT TO
DISRUPT THE ONGOING ACTIVITIES IN THE HOSPITAL.
TEMPORARY MODIFICATIONS OR RELOCATION OF EXISTING SYSTEMS TO
PRESERVE EXISTING LIFE SAFETY FEATURES SUCH AS EXITS, SPRINKLER
SYSTEMS, ALARM SYSTEMS AND OTHER SPECIAL SYSTEMS.
DEMOLITION OF THE EXISTING CONSTRUCTION IN THE FOOTPRINT OF THE
PROJECT SITE AND SAFE REMOVAL AND DISPOSAL OF DEBRIS.
INSTALLATION OF NEW PARTITION SYSTEM, CEILING SYSTEM AND ALL
PLUMBING, MECHANICAL AND ELECTRICAL SYSTEMS AS DEFINED IN THE
DOCUMENTS TO INTERFACE WITH EXISTING SYSTEMS.
PHASING OF THE WORK SUCH THAT THE ABOVE CEILING WORK OUTSIDE OF
THE PROJECT SITE AND SIMILAR WORK OUTSIDE OF THE PROJECT AREA BE
SCHEDULED TO MINIMIZE DISRUPTION AND DOWN-TIME TO AREAS OUTSIDE OF
THE PROJECT SITE.
INSTALLATION OF ALL ARCHITECTURAL FINISHES AND BUILT-IN EQUIPMENT.
FINAL CLEANING AND REMOVAL OF ALL TEMPORARY PARTITION SYSTEMS AND
PROTECTIVE MEASURES. REPAIR OR RESTORATION OF ANY EXISTING
FINISHES OR CONSTRUCTION DAMAGED DURING THE CONSTRUCTION
PROCESS.
FINAL TESTING OF NEW SYSTEMS, TRAINING AND DEMONSTRATION OF NEW
SYSTEMS AND SUBMISSION OF CLOSE-OUT DOCUMENTS. CLOSE-OUT
DOCUMENTS SHALL BE SUBMITTED TO THE OWNER NO LATER THAN 30 DAYS
FOLLOWING THE FINAL ACCEPTANCE OF THE PROJECT.
MODIFICATIONS TO EXISTING HVAC, PLUMBING, ELECTRICAL, FIRE
PROTECTION AND SPECIAL SYSTEMS.
GENERAL SCHEDULING NOTE TO CONTRACTOR
1.
2.
WORK FOR EACH AREA IS TO BE COORDINATED WITH THE COR OR PROJECT ENGINEER.
THE BUILDING SHALL REMAIN OCCUPIED THROUGHOUT CONSTRUCTION. WORK SHALL
BE ARRANGED TO ALLOW AS LITTLE INTERRUPTION AND INCONVENIENCE AS POSSIBLE.
THE CONTRACTOR IS TO SUBMIT A WRITTEN SCHEDULE OF WORK TO THE COR FOR
APPROVAL WHICH DETAILS CONSTRUCTION START AND CONSTRUCTION COMPLETION
FOR EACH AREA. SCHEDULE OF WORK SHALL BE SUBMITTED AND APPROVED BY THE
COR PRIOR TO STARTING ANY WORK ACTIVITIES
CLIENT
PROJECT NAME
PROJECT ADDRESS
OCCUPANCY TYPE
PROJECT GROSS FLOOR
AREA
HEIGHT ABOVE GROUND
NUMBER OF STORIES
TYPE OF CONSTRUCTION
VETERANS ADMINISTRATION
Project Name
1500 E. WOODROW WILSON AVE, JACKSON, MS
PROJECT DATA
6,850 SF
HEALTH CARE (NFPA)
INSTITUTIONAL I2 (IBC)
4 STORIES
TYPE 1A (IBC)
TYPE 1 (332)(NFPA)
MATERIAL SYMBOLS
G002
PROJECT DATA
GRAPHIC SYMBOLS
ABBREVIATIONS
CODES
PROJECT DESCRIPTION
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Consultant:
5190 Canal Boulevard, Suite 201 New Orleans, LA 70124 (504)835-8013
LACHIN
Architects, apc
Architecture . Planning . Project Management
RENOVATION OF PC BLUE FOR
WOMENS HEALTH
1500 E. Woodrow Wilson Dr. Jackson, MS
586-22-102
2/20/2025 MGL TAC
FINAL SUBMISSION
FULLY SPRINKLERED
Revisions: Date:
A
1 2 3 4 5
B
C
D
E
F
FEC
FEC
FEC
FE
FEC
EXIT
EXIT
ELEVATOR
LOBBY
MPE 1
MPE 5
MPE 6
RECEPTION
GPR
SUR CUR CHIEF
MECHANICAL
LACTATION
SWO
MEDICATION
DIETICIAN
PHARM
HAC
STORAGE 5
NURSE
TOILET
ST
OR
AG
E
EHRM
PACT TEAM AREA
STORAGE 1
MPE 4
MPE 3
MPE 2 P. TOILET 1 P. TOILET 2
STAFF
TOILET
NURSE
BREAK ROOM
SUPPLY
GYNO
HALL 2
HALL 1
MHO
EXIT
EXIT
ELEV
ELEV
STORAGE 4
Common Path of Travel - 86'
STAIR 1
STAIR 2
WAITING
Tra ve l D ist an ce
8' to
Ex it
Travel Distance = 129' to Exit
CO
RR
ID
OR
B
MEP CHASE
CORRIDOR A
CO
RR
ID
OR
A
CORRIDOR B
STORAGE 2
Common Path of Travel = 66'
Travel Distance = 173' to Exit
De ad
En d C orr ido r
De ad
En d C orr ido r
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
17.
18.
19.
20.
21.
22.
ALL FIRE WALLS, FIRE BARRIERS, FIRE PARTITIONS & SMOKE BARRIERS AND SMOKE PARTITIONS OR ANY OTHER WALL REQUIRED TO HAVE PROTECTED OPENINGS OR PENETRATIONS SHALL BE EFFECTIVELY AND PERMANENTLY IDENTIFIED WITH SIGNS OR STENCILING. THE ARE TO BE LOCATED IN ACCESSIBLE CONCEALED FLOOR, FLOOR- CEILING OR ATTIC SPACES; BE LOCATED WITHIN 15 FEET OF THE END OF EACH WALL AND AT INTERVALS NOT EXCEEDING 30' MEASURED HORIZONTALLY ALONG THE WALL OR PARTITION; AND INCLUDE LETTERING NOT LESS THAN 3" IN HEIGHT WITH A MINIMUM 3/8" STROKE IN A CONTRASTING COLOR INCORPORATING THE SUGGESTED
WORDING. "FIRE AND/OR SMOKE BARRIER-PROTECT ALL OPENINGS" OR OTHER WORDING.
PROVIDE SURFACE MOUNTED LIGHT FIXTURES AT RATED CEILINGS, UNLESS NOTED/DETAILED OTHERWISE.
REFER TO ELECTRICAL DRAWINGS FOR STROBE, FIRE ALARM AND CARBON MONOXIDE DETECTORS, EMERGENCY LIGHTS, PULL STATIONS, FIRE PANEL LOCATIONS, OTHER
AUDIO AND VISUAL DEVICES, INCLUDING LOCATIONS AND MOUNTING HEIGHT.
PROVIDE CORRESPONDING RATED ACCESS PANEL AT RATED WALLS/CEILINGS. LATCHING AND FINISH TO BE AS SPECIFIED.
REFER TO CORRESPONDING ARCHITECTURAL DRAWINGS FOR WALL AND FLOOR DETAILS.
GC TO PROVIDE CORRESPONDING FIRE CAULK AT RATED WALLS.
SMOKE & DRAFT CONTROL - FIRE DOOR ASSEMBLIES SHALL ALSO MEET THE REQUIREMENTS FOR A SMOKE AND DRAFT CONTROL DOOR ASSEMBLY TESTED IN ACCORDANCE WITH UL1784. DOOR LOUVERS ARE PROHIBITED. INSTALLATION OF SMOKE DOORS SHALL BE IN ACCORDANCE WITH NFPA 105.
PER NFPA 101-8.3.4 GLAZING IN DOOR ASSEMBLIES - IN A 20-MINUTE FIRE DOOR ASSEMBLY, THE GLAZING MATERIAL IN THE DOOR ITSELF SHALL HAVE A MINIMUM FIRE- PROTECTION RATED GLAZING OF 20 MINUTES AND SHALL BE EXEMPT FROM THE HOSE STREAM TEST.
PROVIDE THROUGH-PENETRATION FIRESTOP SYSTEM AS REQUIRED PER THE FIRE RESISTANCE RATING OF THE WALL. REFER TO NFPA 101-8.3.5.
PENETRATIONS OF A FLOOR, FLOOR/CEILING ASSEMBLY OF THE CEILING MEMBRANE OR A ROOF/CEILING ASSEMBLY SHALL COMPLY WITH NFPA 101-8.3.5.
PROVIDE WALL MOUNTED EXIT SIGNS. LOCATE ABOVE ALL EXIT DOORS. REFER TO ELECTRICAL DRAWINGS FOR MOUNTING HEIGHTS AND MODELS.
WHERE AN AIR DUCT PENETRATES ONLY ONE FLOOR OR ONE FLOOR AND AN AIR-HANDLING EQUIPMENT PENTHOUSE FLOOR, AND THE AIR DUCT CONTAINS A FIRE DAMPER LOCATED WHERE THE DUCT PENETRATES THE FLOOR, AN AIR DUCT ENCLOSURE SHALL NOT BE REQUIRED.
FIRE DAMPERS, SMOKE DAMPERS, COMBINATION FIRE/SMOKE DAMPERS AND CEILING RADIATION DAMPERS LOCATION TO BE COORDINATED AT ALL SMOKE AND/OR FIRE RATED PARTITIONS. REFER TO CODE COMPLIANCE PLANS, ELECTRICAL DRAWINGS FOR WIRING DESIGN AND MECHANICAL DRAWINGS.
PORTABLE FIRE EXTINGUISHERS SHALL BE SELECTED, INSTALLED AND MAINTAINED IN ACCORDANCE NFPA 10. BASED ON THIS OCCUPANCY TYPE, CLASS A FOR ORDINARY(MODERATE) HAZARD OCCUPANCY TYPE 2-A FIRE EXTINGUISHERS ARE REQUIRED NO MORE THAN 75' APART AND ON EACH STORY PER TABLE 6.2.1.1 IN NFPA 10.
PROVIDE RECESSED FIRE EXTINGUISHERS AS INDICATED. MOUNT FIRE EXTINGUISHER IN OR WITHOUT CABINET AT 48" AFF TO THE HANDLE. REFER TO SPECIFICATIONS.
CONTRACTOR TO PROVIDE PORTABLE FIRE EXTINGUISHERS EVERY 75 ’ ON THE JOB SITE DURING CONSTRUCTION.
BUILDING UNDER EMERGENCY GENERATOR POWER AS WELL AS UPS. REFER TO OWNER PROVIDED INFORMATION FOR EXISTING SYSTEM REQUIREMENTS.
WHERE CONDUIT, CABLES, AND OTHER ELECTRICAL PROVISIONS PENETRATE RATED WALL AND FLOOR PENETRATIONS PROVIDE ASSEMBLIES CLASSIFIED WITH A UL DESIGNATION AND COMPLY WITH ALL APPLICABLE CODES AND CORRESPONDING TESTING. SUBMIT SUBMITTALS WITH INDICATED UL DESIGNATIONS FOR EACH CONDITION.
CONTRACTOR TO SEAL ALL VOIDS AT INTERSECTION OF PARTITIONS AND FLOOR OR SLAB CONDITIONS, BETWEEN PIPE SLEEVES, AND OTHER PENETRATIONS AT SMOKE
AND FIRE RATED WALL AND FLOOR PENETRATIONS.
NO PENETRATIONS UNRELATED FOR THE PURPOSE OF THE EXIST ACCESS STAIRWAY SHALL BE PERMITTED IN EXIT ACCESS STAIRWAY ENCLOSURES. CONTRACTOR TO NOT INSTALL ELECTRICAL BOXES/OUTLETS, SWITCHES, ETC NOT FOR USE FOR THE EXIT ACCESS STAIRWAY AT ALL THE FIRE RATED PARTITIONS.
REFER TO ELECTRICAL DRAWINGS FOR EMERGENCY GENERATOR LOCATION AND REQUIREMENTS.
EMERGENCY LIGHTING SHALL BE DESIGNED IN ALL PATHS OF EGRESS, IN ROOMS WITH AN OCCUPANCY LOAD OF 50 OR MORE.
CODE COMPLIANCE GENERAL NOTES
ONE HOUR FIRE BARRIER WALL ASSEMBLY
TWO HOUR FIRE BARRIER WALL ASSEMBLY
30 MINUTE SMOKE BARRIER WALL ASSEMBLY
SMOKE PARTITION WALL ASSEMBLY
TRAVEL DISTANCE TO EXIT (TD)
EXIT LIGHT SIGN (SEE ELECT)
COORDINATE WALL VERSUS CEILING MOUNTED
RECESSED FIRE EXTINGUISHER & CABINET
RATED DOOR; INDICATES REQUIRED RATING
ACCUMULATION SPACE
HAZARDOUS AREA
EXISTING AREA - NOT IN CONTRACT
LEGEND
FEC
S S
SP SP
EXISTING WALL
2 3 4 5
Tr av el D is ta nc e
' t o
Ex it
LS101
LIFE SAFETY PLAN
1/8" = 1'-0"LS101
1 1st Floor - Life Safety Plan
OCCUPANCY TYPE: INSTITUTIONAL I-2 (IBC)
OCCUPANT LOAD: (240 SQFT/PERSON) 29 PERSONS
MAXIMUM TRAVEL DISTANCE: 200 FT.
MAXIMUM COMMON PATH OF TRAVEL:
MAXIMUM DEAD END: 30 FT
HAZARD CLASSIFICATION: ORDINARY
KEY PLAN - FIRST FLOOR
HEALTHCARE (NFPA 101)
AREA: CLINIC: 6,850 SQFT.
100 FT.
CONSTRUCTION TYPE: 1A (IBC)
1 (332) NFPA 101
CODE REQUIREMENTS
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Consultant:
5190 Canal Boulevard, Suite 201 New Orleans, LA 70124 (504)835-8013
LACHIN
Architects, apc
Architecture . Planning . Project Management
RENOVATION OF PC BLUE FOR
WOMENS HEALTH
1500 E. Woodrow Wilson Dr. Jackson, MS
586-22-102
2/20/2025 MGL TAC
FINAL SUBMISSION
FULLY SPRINKLERED
Revisions: Date:
1/8" = 1'-0"LS101
2 2ND Floor / Pent House - Life Safety Plan
Pent House: 837 SQFT.
AutoCAD SHX Text 18'-0"
AutoCAD SHX Text 20'-0"
AutoCAD SHX Text 20'-0"
AutoCAD SHX Text 20'-0"
AutoCAD SHX Text 21'-6"
AutoCAD SHX Text 19'-2"
AutoCAD SHX Text 20'-0"
AutoCAD SHX Text 19'-6"
AutoCAD SHX Text 10'-6"
AutoCAD SHX Text 90'-8"
AutoCAD SHX Text 9'-11"
AutoCAD SHX Text 10'-4"
AutoCAD SHX Text 49'-4"
AutoCAD SHX Text 41'-3 1/8"
AutoCAD SHX Text 98'-1 1/2"
AutoCAD SHX Text
EXIST. RF-1
AutoCAD SHX Text
HWP 1
AutoCAD SHX Text
HWP 2
AutoCAD SHX Text
HX-1
AutoCAD SHX Text
HX-2
AutoCAD SHX Text
VFMD 1
AutoCAD SHX Text
VFMD 2
AutoCAD SHX Text
COPY
AutoCAD SHX Text
FILE
AutoCAD SHX Text
FILE
AutoCAD SHX Text
FILE
AutoCAD SHX Text
FILE
AutoCAD SHX Text
ICE
AutoCAD SHX Text
REF.
AutoCAD SHX Text S
AutoCAD SHX Text
MICROWAVE ABOVE
AutoCAD SHX Text
PYXIS
AutoCAD SHX Text U.C.
AutoCAD SHX Text
REF.
AutoCAD SHX Text
MOP
AutoCAD SHX Text
CRASH CART
AutoCAD SHX Text
FILE
AutoCAD SHX Text
COPY
AutoCAD SHX Text
EXISTING TO REMAIN
AutoCAD SHX Text
EXISTING TO REMAIN
AutoCAD SHX Text 16'-4 5/8"
AutoCAD SHX Text
EXISTING TO REMAIN
AutoCAD SHX Text
BLDG. EXPANSION JOINT
AutoCAD SHX Text
BLDG. EXPANSION JOINT
AutoCAD SHX Text
SP
AutoCAD SHX Text 21'-8 3/4"
AutoCAD SHX Text
2010 LA ADDITION
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text
SP
AutoCAD SHX Text
SP
AutoCAD SHX Text
SP
AutoCAD SHX Text
SP
AutoCAD SHX Text
SP
AutoCAD SHX Text
SP
AutoCAD SHX Text
SP
AutoCAD SHX Text
SP
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text
SP
AutoCAD SHX Text
SP
AutoCAD SHX Text
SP
AutoCAD SHX Text
SP
AutoCAD SHX Text
SP
AutoCAD SHX Text
SP
AutoCAD SHX Text
SP
AutoCAD SHX Text
SP
AutoCAD SHX Text
SP
AutoCAD SHX Text
SP
AutoCAD SHX Text
SP
AutoCAD SHX Text
SP
AutoCAD SHX Text
SP
AutoCAD SHX Text
SP
AutoCAD SHX Text
SP
AutoCAD SHX Text
SP
AutoCAD SHX Text
SP
AutoCAD SHX Text
SP
AutoCAD SHX Text
SP
AutoCAD SHX Text
SP
AutoCAD SHX Text
SP
AutoCAD SHX Text
SP
AutoCAD SHX Text
SP
AutoCAD SHX Text
SP
AutoCAD SHX Text
SP
AutoCAD SHX Text
SP
AutoCAD SHX Text
SP
AutoCAD SHX Text
SP
AutoCAD SHX Text
SP
AutoCAD SHX Text
SP
AutoCAD SHX Text
SP
AutoCAD SHX Text
SP
AutoCAD SHX Text
SP
AutoCAD SHX Text
SP
AutoCAD SHX Text
SP
AutoCAD SHX Text
SP
AutoCAD SHX Text
SP
AutoCAD SHX Text
SP
AutoCAD SHX Text
SP
AutoCAD SHX Text
SP
AutoCAD SHX Text
SP
AutoCAD SHX Text
SP
AutoCAD SHX Text
SP
AutoCAD SHX Text
SP
AutoCAD SHX Text
SP
AutoCAD SHX Text
SP
AutoCAD SHX Text
SP
AutoCAD SHX Text
SP
AutoCAD SHX Text
SP
AutoCAD SHX Text
SP
AutoCAD SHX Text
SP
AutoCAD SHX Text
SP
AutoCAD SHX Text
SP
AutoCAD SHX Text
SP
AutoCAD SHX Text
SP
AutoCAD SHX Text
SP
AutoCAD SHX Text
SP
AutoCAD SHX Text
SP
AutoCAD SHX Text
SP
AutoCAD SHX Text
SP
AutoCAD SHX Text
SP
AutoCAD SHX Text
SP
AutoCAD SHX Text
SP
AutoCAD SHX Text
SP
AutoCAD SHX Text
SP
AutoCAD SHX Text
SP
AutoCAD SHX Text
SP
AutoCAD SHX Text
SP
AutoCAD SHX Text
SP
AutoCAD SHX Text
SP
AutoCAD SHX Text
SP
AutoCAD SHX Text
SP
AutoCAD SHX Text
SP
AutoCAD SHX Text
SP
AutoCAD SHX Text
SP
AutoCAD SHX Text
SP
AutoCAD SHX Text
SP
AutoCAD SHX Text
SP
AutoCAD SHX Text
SP
AutoCAD SHX Text
SP
AutoCAD SHX Text
SP
AutoCAD SHX Text
SP
AutoCAD SHX Text
SP
AutoCAD SHX Text
SP
AutoCAD SHX Text
SP
AutoCAD SHX Text
SP
AutoCAD SHX Text
SP
AutoCAD SHX Text
SP
AutoCAD SHX Text
SP
AutoCAD SHX Text
SP
AutoCAD SHX Text
SP
AutoCAD SHX Text
SP
AutoCAD SHX Text
SP
AutoCAD SHX Text
SP
AutoCAD SHX Text
SP
AutoCAD SHX Text
SP
AutoCAD SHX Text
SP
AutoCAD SHX Text
SP
AutoCAD SHX Text
EXISTING FLOOR/CLG. PENETRATION
AutoCAD SHX Text
EXISTING FLOOR/CLG. PENETRATION
AutoCAD SHX Text 20'-0"
AutoCAD SHX Text 20'-0"
AutoCAD SHX Text 20'-0"
AutoCAD SHX Text 10'-2 1/2"
AutoCAD SHX Text
PUMP 1
AutoCAD SHX Text
PUMP 2
AutoCAD SHX Text
AHU 1
AutoCAD SHX Text
VFD 2
AutoCAD SHX Text
VFD 1
AutoCAD SHX Text
NEW INSULATED METAL COILING DOOR
AutoCAD SHX Text
NEW 2" INSULATED METAL PANELS OVER 8" GIRTS
AutoCAD SHX Text
EXISTING STAIR
EXIT
AREA OF WORK
128' 129'
126'
LS102
LIFE SAFETY PLAN - OVERALL
FIRST LEVEL
1" = 360'-0"LS102
1 Life Safety Plan - Overall First Level
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Consultant:
5190 Canal Boulevard, Suite 201 New Orleans, LA 70124 (504)835-8013
LACHIN
Architects, apc
Architecture . Planning . Project Management
RENOVATION OF PC BLUE FOR
WOMENS HEALTH
1500 E. Woodrow Wilson Dr. Jackson, MS
586-22-102
2/20/2025 MGL TAC
FINAL SUBMISSION
FULLY SPRINKLERED
Revisions: Date:
B
C
D
E
F
Ex A
Ex A
Ex A
Ex A Ex A
Ex B
Ex B
Ex B
Ex A
Ex A
Ex CEx C
Ex F
Ex D
Ex E
Ex A
E
E
BC-1212
BC-1213
BC-1219
STAIR 11
MECH.
STAIR
STAIR 8
CHASE
BC-1208
BC-1207
BC-1206
BC-1205
BC-1203
BC-1204
BC-1209
C O
R R
ID
O
R C
-2
BC-1216
T-1 T-2
T-3
T-4
EXIT
EXIT
EXIT
BC-1202
BC-1237
BC-1236 BC-1235 BC-1234 BC-1233 BC-1232
CORRIDOR C-8
CORRIDOR C-5
BC-1226
WAITING
BC-1220 BC-1222
T-5
T-6
T-7
BC-1230
BC-1214
BC-1215 BC-1221 BC-1223 BC-1225 BC-1227
BC-1224
C-6
C-7
A
1 2 3 4 5
B
C
D
E
F
BC-1212 BC-1213
BC-1219
STAIR 11
MECH.
STAIR
STAIR 8
CHASE
BC-1208
BC-1207
BC-1206
BC-1205
BC-1203 BC-1204
BC-1209
C O
R R
ID
O
R C
-2 BC-1216
T-1 T-2
T-3
T-4
EXIT
EXIT
EXIT
BC-1202
BC-1237
BC-1236 BC-1235 BC-1234 BC-1233 BC-1232
CORRIDOR C-8
CORRIDOR C-5
BC-1226
WAITING
BC-1220
BC-1222
T-5
T-6
T-7
BC-1230
BC-1214
BC-1215
BC-1221 BC-1223 BC-1225 BC-1227
BC-1224
C-6
C-7
WALL TYPE (SHEET AD102)
LEGEND
EXISTING PARTITION TO REMAIN
Ex A
DEMOLISH PARTITION
DEMOLISH PLUMBING FIXTURE
DEMOLISH DOOR AND FRAME
DEMOLISH LIGHT FIXTURE
DEMOLISH MECH. DIFFUSER
NEW WALL TYPE (SHEET A602)E
1/8" = 1'-0"AD100
1 1st Floor Demolition Plan
1/8" = 1'-0"AD100
2 1st Floor Demolition RCP
AD100
ARCHITECTURAL DEMO FLOOR
PLAN & RCP
KEY PLAN - FIRST FLOOR
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Consultant:
5190 Canal Boulevard, Suite 201 New Orleans, LA 70124 (504)835-8013
LACHIN
Architects, apc
Architecture . Planning . Project Management
RENOVATION OF PC BLUE FOR
WOMENS HEALTH
1500 E. Woodrow Wilson Dr. Jackson, MS
586-22-102
2/20/2025 MGL TAC
FINAL SUBMISSION
FULLY SPRINKLERED
Revisions: Date:
DEMOLITION KEY NOTES
EXISTING CEILING SYSTEMS TO REMAIN - PROTECT FROM DAMAGE.
TEMPORARILY REMOVE EXISTING CEILING SYSTEM TO INSTALL NEW ABOVE
CEILING WORK. RESTORE OR REPLACE EXISTING CEILING SYSTEM TO MATCH
AFTER INSTALLATION.
REMOVE ALL EXISTING PLUMBING FIXTURES
EXISTING FINISHES ARE TO REMAIN IN THIS AREA - PROTECT FROM DAMAGE
REMOVE ALL DRYWALL AND FURRING AT EXTERIOR WALL AND AROUND ALL
COLUMNS, TYPICAL
1. ALL EXISTING PLUMBING IDENTIFIED TO BE DEMOLISHED SHALL BE REMOVED WITH LINES CAPPED. REFER TO PLUMBING SHEETS
FOR ADDITIONAL SCOPE. MAINTAIN SECURITIES TO FLOORS ABOVE AND BELOW.
2. DEMOLISH EXISTING FLOORING THROUGHOUT THE LIMITS OF WORK.
3. DEMOLISH EXTERIOR WALL FINISHES. EXTERIOR WALL CONSTRUCTION IS TO REMAIN UNLESS NOTED OTHERWISE.
4. ITEMS SHOWN DASHED ARE TO BE DEMOLISHED, INCLUDING ALL CABINET WORK.
5. DEMOLISH EXISTING PARTITIONS HANDRAILS, CRASH RAILS, CORNER GUARDS, AND SHEET WALL PROTECTION PANELS
THROUGHOUT THE LIMITS OF WORK.
6. DEMOLISH EXISTING CEILING AND ALL CEILING DEVICES THROUGHOUT THE LIMITS OF WORK. SEE ELECTRICAL SHEETS FOR
ADDITIONAL SCOPE AND ITEMS TO BE RELOCATED.
7. REMOVE AND DELIVER TO COR ALL EQUIPMENT, FIXTURES, OR ACCESSORIES IDENTIFIED BY THE COR TO BE SALVAGED. DELIVER
SALVAGEABLE ITEMS TO THE COR AS DIRECTED.
8. REMOVE ALL EXISTING PLUMBING FIXTURES THROUGHOUT THE LIMITS OF WORK. CONTRACTOR TO COORDINATE REMOVAL OF PLUMBING FIXTURES AND CAPPING PIPING TO MINIMIZE DISRUPTION TO PLUMBING ABOVE AND BELOW. RE-ROUTING OF PLUMBING LINES THAT SERVE THE FIRST AND THIRD FLOORS SHALL BE PHASED AND COORDINATED WITH THE COR TO MINIMIZE
DISRUPTIONS TO SYSTEMS ABOVE AND BELOW THE SCHEDULED WORK.
9. COORDINATE SLAB DEMOLITION AND RESTORATION WITH NEW PLUMBING WORK.
10. COORDINATE DEMOLITION MATERIALS REMOVAL PROCEDURES WITH THE COR.
11. AT ALL WALLS TO REMAIN, CONTRACTOR TO REMOVE ALL WALL MOUNTED ITEMS, INCLUDING BUT NOT LIMITED TO: SWITCHES, OUTLETS, FIXTURES & EQUIPMENT. REFER TO MECHANICAL & ELECTRICAL SHEETS FOR ADDITIONAL SCOPE.
GENERAL DEMOLITION NOTES
1 2
3 33
1. REMOVE ALL EXISTING CEILING SYSTEMS INCLUDING ALL CEILING MOUNTED DEVICES AND SYSTEMS WITHIN THE PROJECT AREA.
COORDINATE WITH THE COR AND ITEMS TO BE SALVAGED OR RE-USED. NOT ALL CEILING MOUNTED DEVICES ARE SHOWN ON THIS DRAWING. CONTRACTORS ARE TO VISIT THE SITE AND TAKE NOTE OF THE SCOPE OF ALL EXISTING DEVICES TO BE REMOVED.
2. COORDINATE ANY REMOVAL OF ANY SYSTEM(S) THAT MIGHT DISRUPT OR INTERRUPT THE ONGOING OPERATIONS OF ANY AREA
OUTSIDE OF THE PROJECT AREA.
3. REMOVE ALL LIGHT FIXTURES. COORDINATE WITH THE COR AND ITEMS TO BE SALVAGED OR RE-USED.
GENERAL REFLECTED CEILING DEMOLITION NOTES
AutoCAD SHX Text 18'-0"
AutoCAD SHX Text 20'-0"
AutoCAD SHX Text 20'-0"
AutoCAD SHX Text 20'-0"
AutoCAD SHX Text 21'-6"
AutoCAD SHX Text 19'-2"
AutoCAD SHX Text 20'-0"
AutoCAD SHX Text 19'-6"
AutoCAD SHX Text 10'-6"
AutoCAD SHX Text 90'-8"
AutoCAD SHX Text 9'-9 1/2"
AutoCAD SHX Text 10'-2 1/2"
AutoCAD SHX Text 49'-0"
AutoCAD SHX Text 41'-1 5/8"
AutoCAD SHX Text 98'-0"
AutoCAD SHX Text
2010 LA ADDITION
AutoCAD SHX Text
EXISTING SERVER TO RELOCATE TO NEW LOCATION. SEE PROPOSED PLAN
AutoCAD SHX Text 10'-2 3/4"
AutoCAD SHX Text
EXISTING TO REMAIN
AutoCAD SHX Text
EXISTING TO REMAIN
AutoCAD SHX Text DEMOLISH EXISTING AIR-HANDLING UNIT, SEE MECHANICAL DRAWINGS FOR ADDITIONAL SCOPE
AutoCAD SHX Text
DEMO CURB
AutoCAD SHX Text
DEMOLISH CHILLED WATER BOOSTER PUMP
AutoCAD SHX Text
CHILLED WATER PIPING FLOOR PENETRATIONS
AutoCAD SHX Text
EXISTING FLOOR OPENING TO REMAIN
AutoCAD SHX Text
EXISTING FAN UNIT AND DUCT TO REMAIN.
AutoCAD SHX Text
DEMOLISH EXISTING THROUGH WALL DUCT WORK
AutoCAD SHX Text
MAINTAIN A WEATHER TIGHT SEAL DURING CONSTRUCTION.
AutoCAD SHX Text
AutoCAD SHX Text
DEMOLISH PUMP
AutoCAD SHX Text
EXISTING FLOOR OPENING TO REMAIN
AutoCAD SHX Text
BUILDING EXPANSION JOINT
AutoCAD SHX Text
INSTALL TEMPORARY 1 HOUR FIRE RATED CONSTRUCTION DOORS PRIOR TO DEMOLITION
AutoCAD SHX Text LINE OF TEMPORARY ONE HOUR FIRE RATED PARTITION. INSTALL PRIOR TO DEMOLITION AND NEW WORK
AutoCAD SHX Text
COORDINATE ACCEPTABLE CORRIDOR CLEARANCE WITH COR
AutoCAD SHX Text 6'-8 3/8"
AutoCAD SHX Text 6"
AutoCAD SHX Text 3'-0"
AutoCAD SHX Text 3'-0"
AutoCAD SHX Text 18'-0"
AutoCAD SHX Text 20'-0"
AutoCAD SHX Text 20'-0"
AutoCAD SHX Text 20'-0"
AutoCAD SHX Text 21'-6"
AutoCAD SHX Text 19'-2"
AutoCAD SHX Text 20'-0"
AutoCAD SHX Text 19'-6"
AutoCAD SHX Text 10'-6"
AutoCAD SHX Text 90'-8"
AutoCAD SHX Text 9'-9 1/2"
AutoCAD SHX Text 10'-2 1/2"
AutoCAD SHX Text 49'-0"
AutoCAD SHX Text 41'-1 5/8"
98'-0"
B
C
D
E
P
E
E
A
1 2 3 4 5
B
C
D
E
P
AREAS OF POTENTIAL CEILING
DEMOLITION DUE TO PLUMBING
REQUIREMENTS AT FLOOR ABOVE.
Room M-39
Room M-22
Room M-21
Room M-19
Room M-42
Room M-36
Room M-35
Room M-17
Room M-12
Room M-13
GYPSUM BOARD CEILING
GYPSUM BOARD CEILING
GYPSUM BOARD CEILING
AD101
ARCHITECTURAL DEMO PLANS
AND RCP
1/8" = 1'-0"AD101
1 2nd Level Demolition Plan
1/8" = 1'-0"AD101
2 Basement Level Demolition RCP - Radiological Oncology
KEY PLAN - FIRST FLOOR
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Consultant:
5190 Canal Boulevard, Suite 201 New Orleans, LA 70124 (504)835-8013
LACHIN
Architects, apc
Architecture . Planning . Project Management
RENOVATION OF PC BLUE FOR
WOMENS HEALTH
1500 E. Woodrow Wilson Dr. Jackson, MS
586-22-102
2/20/2025 MGL TAC
FINAL SUBMISSION
FULLY SPRINKLERED
Revisions: Date:
NOTE
SOME AREAS OF THE FIRST FLOOR SUCH AS ONCOLOGY AND OTHER AREAS ARE
PARTICULARLY SENSITIVE TO DISRUPTION. THEY WILL REQUIRE CLOSE COORDINATION WITH
THE COR TO IDENTIFY THE AVAILABLE TIMES AND LENGTH OF DISRUPTION THAT WILL BE
ACCEPTABLE TO MINIMIZE DOWN-TIME IN THESE AREAS. SOME AFTER-HOURS WORK SHOULD
BE ANTICIPATED AND CAREFULLY SCHEDULED WITH THE COR. TEMPORARY RE-ROUTING OF
PLUMBING MAY BE REQUIRED TO MINIMIZE DISRUPTION OF SERVICES TO THE THIRD FLOOR
ABOVE THE WORK AREA UNTIL THE PERMANENT PLUMBING SYSTEM IS IN PLACE.
THIS FLOOR PLAN ILLUSTRATES THE GENERAL LAYOUT OF AREAS ON THE FIRST FLOOR BELOW
THE SECOND FLOOR WARD 2A AREA WHERE THE BULK OF DEMOLITION AND CONSTRUCTION
WILL BE OCCURRING. AS THIS DRAWING WAS CREATED FROM THE BEST AVAILABLE DRAWINGS
OF THIS AREA AT THAT TIME, SOME DIFFERENCES TO THE LAYOUT SHOULD BE EXPECTED AS
THERE HAS BEEN SOME MINOR RENOVATION WORK THAT HAS OCCURRED SINCE THE DRAWING
WAS CREATED.
GENERAL NOTES
1.
2.
3.
THIS SHEET IS INCLUDED AS A COURTESY AND SHOWS APPROXIMATE LOCATIONS OF
EXISTING SPACES AND PARTITIONS ON THE FLOOR BELOW THE AREA OF WORK TO ASSIST
THE CONTRACTOR IN COORDINATING AND SCHEDULING THE ABOVE CEILING WORK WITH
THE COR. ACCURACY OF THIS PLAN IS NOT GUARANTEED AS IT WAS DRAWN FROM THE
BEST AVAILABLE AS-BUILT DRAWINGS PROVIDED BY THE OWNER. CONTRACTOR TO VISIT
THE SITE TO CONFIRM EXISTING CONDITIONS.
WITH THE EXCEPTION OF ABOVE CEILING WORK AND REPAIR OR REPLACEMENT OF CEILING
AND RELATED SYSTEMS, NO NEW WORK IS TO OCCUR ON THIS FLOOR EXCEPT AS
NECESSARY TO INSTALL THE WORK AT THE SECOND FLOOR.
ANY DAMAGES OR DISRUPTIONS TO THE EXISTING CONSTRUCTION ON THIS FLOOR AS A
RESULT OF INSTALLING WORK FOR THE SECOND FLOOR SHALL BE REPAIRED AND
COORDINATED WITH THE COR.
CEILING AREAS TO BE DISRUPTED TO
INSTALL / MODIFY ABOVE CEILING
CONSTRUCTION
LEGEND
GYPSUM BOARD CEILING
4. CEILING TYPE IS 2X2 ACOUSTICAL CEILING TILE UNLESS OTHERWISE NOTED.
AutoCAD SHX Text 13'-4"
AutoCAD SHX Text 8'-4"
AutoCAD SHX Text DEMOLISH EXISTING ROOFING SYSTEM AND PERIMETER FLASHING. PROVIDE TEMPORARY PROTECTION DURING DEMOLITION.
AutoCAD SHX Text
NO WORK
AutoCAD SHX Text
TEMPORARY PARTITION
AutoCAD SHX Text
DEMOLISH EXTERIOR WALL TO ACCOMMODATE NEW OPENING
AutoCAD SHX Text 8"
AutoCAD SHX Text 8"
AutoCAD SHX Text REMOVE AND SALVAGE BRICK VENEER FROM SECOND FLOOR TO TOP OF ROOF DECK. TERMINATE DEMOLITION 8" FROM EDGE OF ROOF WITH SAW CUT. DEMOLISH AND DISCARD BRICK TIES. PREP STUD WALLS AND SHEATHING FOR NEW WORK.
AutoCAD SHX Text 19'-1 5/8"
AutoCAD SHX Text 40'-3 5/8"
DEMOLISH ROOF DRAIN
Existing Demo Partition Type - Ex A
SILL
PLAN
SILL
PLAN
Existing Demo Partition Type - Ex B Existing Demo Partition Type - Ex C
SILL
PLAN
Existing Demo Partition Type - Ex D Existing Demo Partition Type - Ex E
SILL
PLAN
SILL
PLAN
Existing Demo Partition Type - Ex F
SILL
PLAN
EXISTING CMU WALL/STRUCTURE
AD102
WALL TYPES - SELECTIVE
DEMOLITION
3/4" = 1'-0"1 EXISTING PARTITION TYPES - DEMOLITION
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Consultant:
5190 Canal Boulevard, Suite 201 New Orleans, LA 70124 (504)835-8013
LACHIN
Architects, apc
Architecture . Planning . Project Management
RENOVATION OF PC BLUE FOR
WOMENS HEALTH
1500 E. Woodrow Wilson Dr. Jackson, MS
586-22-102
2/20/2025 MGL TAC
FINAL SUBMISSION
FULLY SPRINKLERED
Revisions: Date:
AutoCAD SHX Text
VARIES
AutoCAD SHX Text
EXISTING CMU WALL/STRUCTURE TO REMAIN
AutoCAD SHX Text
DEMOLISH EXISTING LAY-IN CEILING
AutoCAD SHX Text
DEMOLISH " GYP. BD. 58" GYP. BD. AND " MTL. HAT 78" MTL. HAT CHANNELS
AutoCAD SHX Text
DEMOLISH EXISTING BASEBOARD
AutoCAD SHX Text
EXISTING CONCRETE DECK/CEILING
AutoCAD SHX Text
EXISTING CMU WALL/STRUCTURE
AutoCAD SHX Text
EXISTING CONCRETE DECK/CEILING
AutoCAD SHX Text
VARIES
AutoCAD SHX Text
EXISTING CONCRETE DECK/CEILING
AutoCAD SHX Text
DEMOLISH " GYP. BD. 58" GYP. BD. AND 4" MTL. STUDS.
AutoCAD SHX Text
DEMOLISH EXISTING LAY-IN CEILING
AutoCAD SHX Text
EXISTING CMU WALL/STRUCTURE TO REMAIN
AutoCAD SHX Text
DEMOLISH EXISTING BASEBOARD
AutoCAD SHX Text
VARIES
AutoCAD SHX Text
EXISTING 4" METAL STUD TO REMAIN
AutoCAD SHX Text
VARIES
AutoCAD SHX Text 9"
AutoCAD SHX Text
EXISTING CMU WALL/STRUCTURE TO REMAIN
AutoCAD SHX Text
GYPSUM WALL BOARD TO REMAIN, PREP TO RECEIVE NEW PAINT
AutoCAD SHX Text
DEMOLISH EXISTING BASEBOARD
AutoCAD SHX Text
DEMOLISH EXISTING LAY-IN CEILING
AutoCAD SHX Text
DEMOLISH EXISTING LAY-IN CEILING
AutoCAD SHX Text
EXISTING 4" METAL STUD TO REMAIN
AutoCAD SHX Text
GYPSUM WALL BOARD TO REMAIN, PREP TO RECEIVE NEW PAINT
AutoCAD SHX Text
DEMOLISH EXISTING BASEBOARD
AutoCAD SHX Text
EXISTING CONCRETE DECK/CEILING
AutoCAD SHX Text
EXISTING 4" METAL STUD TO REMAIN
AutoCAD SHX Text
GYPSUM WALL BOARD TO REMAIN, PREP TO RECEIVE NEW PAINT
AutoCAD SHX Text
DEMOLISH EXISTING BASEBOARD
AutoCAD SHX Text EXISTING PARTITION TO REMAIN A 2 HOUR RATED ASSEMBLY DURING CONSTRUCTION AND UPON PROJECT COMPLETION.
AutoCAD SHX Text
AutoCAD SHX Text
EXISTING CONCRETE DECK/CEILING
AutoCAD SHX Text
EXISTING CONCRETE DECK/CEILING
AutoCAD SHX Text
VARIES
AutoCAD SHX Text EXISTING PARTITION TO REMAIN A 2 HOUR RATED ASSEMBLY DURING CONSTRUCTION AND UPON PROJECT COMPLETION.
AutoCAD SHX Text
AutoCAD SHX Text EXISTING PARTITION TO REMAIN A 2 HOUR RATED ASSEMBLY DURING CONSTRUCTION AND UPON PROJECT COMPLETION.
BC-1212 BC-1213
BC-1219
STAIR 11
MECH.
STAIR
STAIR 8
CHASE
BC-1208
BC-1207
BC-1206
BC-1205
BC-1203
BC-1204
BC-1209
C O
R R
ID
O
R C
-2
BC-1216
T-1 T-2
T-3
T-4
EXIT
EXIT
EXIT BC-1202
BC-1237
BC-1236 BC-1235 BC-1234 BC-1233 BC-1232
CORRIDOR C-8
CORRIDOR C-5
BC-1226
WAITING
BC-1220 BC-1222
T-5
T-6
T-7
BC-1230
BC-1214
BC-1215 BC-1221 BC-1223 BC-1225 BC-1227
BC-1224
C-6
C-7
A
1 2 3 4 5
B
C
D
E
F
A
1 2 3 4 5
B
C
D
E
F
NO WORK
1/8" = 1'-0"A100 1 First Floor Phasing Plan
A100
ARCHITECTURAL PHASING PLAN
KEY PLAN - FIRST FLOOR
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Consultant:
5190 Canal Boulevard, Suite 201 New Orleans, LA 70124 (504)835-8013
LACHIN
Architects, apc
Architecture . Planning . Project Management
RENOVATION OF PC BLUE FOR
WOMENS HEALTH
1500 E. Woodrow Wilson Dr. Jackson, MS
586-22-102
2/20/2025 MGL TAC
FINAL SUBMISSION
FULLY SPRINKLERED
Revisions: Date:
GENERAL PHASING NOTES
CONTRACTOR TO COORDINATE WITH COR AND SUBMIT A DETAILED
PHASING PLAN FOR THE WORK BEFORE CONSTRUCTION BEGINS.
PHASING PLAN SHALL BE APPROVED BY THE COR.
THE DETAILED PHASING PLAN SHOULD INCLUDE PHASED DISRUPTION
DURATIONS OF SPACES ABOVE THE SECOND FLOOR AND SPACES
BELOW THE SECOND FLOOR THAT WILL BE NECESSARY TO INSTALL
THIS NEW WORK.
1/8" = 1'-0"A100 2 Second Floor - Pent House Phasing Plan
KEY PLAN - Second Floor - Mech. PentHouse
AutoCAD SHX Text
BUILDING EXPANSION JOINT
AutoCAD SHX Text 6'-8 3/8"
AutoCAD SHX Text 6"
AutoCAD SHX Text 3'-0"
AutoCAD SHX Text 3'-0"
AutoCAD SHX Text
TEMPORARY PARTITION, DOOR & FRAME
AutoCAD SHX Text
COORDINATE ACCEPTABLE CORRIDOR CLEARANCE WITH COR
AutoCAD SHX Text 18'-0"
AutoCAD SHX Text 20'-0"
AutoCAD SHX Text 20'-0"
AutoCAD SHX Text 20'-0"
AutoCAD SHX Text 21'-6"
AutoCAD SHX Text 19'-2"
AutoCAD SHX Text 20'-0"
AutoCAD SHX Text 19'-6"
AutoCAD SHX Text 10'-6"
AutoCAD SHX Text 90'-8"
AutoCAD SHX Text 9'-9 1/2"
AutoCAD SHX Text 10'-2 1/2"
AutoCAD SHX Text 49'-0"
AutoCAD SHX Text 41'-1 5/8"
AutoCAD SHX Text 98'-0"
AutoCAD SHX Text
RF-1
AutoCAD SHX Text
AHU-1
AutoCAD SHX Text 18'-0"
AutoCAD SHX Text 20'-0"
AutoCAD SHX Text 20'-0"
AutoCAD SHX Text 20'-0"
AutoCAD SHX Text 21'-6"
AutoCAD SHX Text 19'-2"
AutoCAD SHX Text 20'-0"
AutoCAD SHX Text 19'-6"
AutoCAD SHX Text 10'-6"
AutoCAD SHX Text 90'-8"
AutoCAD SHX Text 9'-9 1/2"
AutoCAD SHX Text 10'-2 1/2"
AutoCAD SHX Text
EXISTING FLOOR PENETRATION
AutoCAD SHX Text
PUMP 1
AutoCAD SHX Text
PUMP 2
AutoCAD SHX Text
EXISTING FLOOR PENETRATION
AutoCAD SHX Text
AHU 1
AutoCAD SHX Text
VFD 2
AutoCAD SHX Text
VFD 1
AutoCAD SHX Text
NEW INSULATED METAL COILING DOOR
AutoCAD SHX Text
NEW 2" INSULATED METAL PANELS OVER 8" GIRTS
1HR. TEMPORARY PARTITION AND DOORS
B
C
D
E
F
FEC
FEC
FEC
FE
FEC
ELEVATOR LOBBY STAIRWELL
MEP CHASE
2010 LA Addition
STAIR 1
MPE 1
115 B
MPE 5
109 B
MPE 6
108 B
RECEPTION
116 A
WAITING
100 D
GPR
118 B
SUR
124 A
CUR
125 A
CHIEF
126 A
MECHANICAL
123 E
LACTATION
101 A
SWO
139 A
MEDICATION
128 A
DIETICIAN
129 A
PHARM
130 A
HAC
135 A
STORAGE 5
131 A
NURSE
121 A
TOILET
119 C ST
OR
AG
E
A
EHRM
140 E
PACT TEAM AREA
105 A
CORRIDOR A
102 A
STORAGE 1
107 A
MPE 4
110 B
MPE 3
111 B
MPE 2
114 B P. TOILET 1
113 C
P. TOILET 2
112 C
STORAGE 2
103 A
STAFF TOILET
136 C
NURSE
137 A
BREAK ROOM
132 C
SUPPLY
GYNO
133 A
HALL 2
104 A
HALL 1
106 A
MHO
138 A
CORRIDOR B
120 A STORAGE 4
127 A
6 MTL LOCKERS
102A
116A 116B
118B
8A
102B
114A115A
115B 114B
111B
0B
0A
1A
9A
9B
108B 10 8A
A104
A104
A104
A201
0A
A104
A104
FLOOR AND CEILING
EXPANSION JOINT COVER
C3 C3
C3
C3
D3
C3
C3
C3
C3
C3D3
C3
C3
C3
C3
C3
C3
C3
C3
C3
C3
C3
C3
C3
C3
E3
C3C3
C3 C3
C3 C3
C3
F3
F3
D3
C3
E3 C3
C3
C3
C3
C3
A0
TYP AT ALL
COLUMNS
CO
RR
ID
OR
A
A
A0 F3
D3 C3
A0
C3
B
C3
C3
D3
C3
A0
A0
E3
A1
A0
C3
C3 A0
A0
C3
A0
E3
C3
C3 E3
B
C3
A0
A0
D3
D3
B
C3
C3 A0
D3D3
C3 A
2C
A2A0
A2
A2
A2
A2
A2
A2
E3
A2
A2
A2
A0
E3
A2 A3 A0
A0
A0
A2
A2
A0
E3
A0
A A
C3
E3
E3
C3
C3
A0A0
E3
E3
E6
A104
A106
25 14
5 6
MECHANICAL
PENTHOUSE
200 E
NEW HM DOOR AND FRAME
NEW 96"x96" OVERHEAD
COILING DOOR
A201
PREFINISHED INSULATED
METAL WALL PANEL
CONCRETE CURB
REF TO STRUCTURAL
STEEL COLUMN
REF TO STRUCTURAL
STEEL WALL GIRT
REF TO STRUCTURAL
NEW MECH EQUIPMENT
REF TO MECH
1'-0
8'-0
16' -6
1/2
200B
200A
A201
A201
A201
A
1 2 3 4 5
B
C
D
E
F
CO
RR
ID
OR
PCC 2133
PCC
2133A
PCC
PCC 2131 PC
C
PCC 2130
PCC 2104
HAC
PCC 2108 PCC 2129
PCC 2107
PCC 2128
PCC 2109
PCC 2110
PCC 2112
STAIR
ELECTRICALIT CLOSET
PCC 2113 PCC 2114 PCC 2115 PCC 2117 PCC 2119
PCC 2120
PCC 2121
PCC 2122
PCC 2123
PCC 2124
PCC 2118
PCC 2125
PCC 2116
PCC 2126
PCC 2111
STORAGE
CORRIDOR
GUARD RAIL SEE DETAILS 3:A201
& 14:A202
CORNER GUARD
WALL TYPE (SHEET A601)
RECESSED FIRE EXTINGUISHER & CABINET
LEGEND
FEC
EXISTING PARTITION TO REMAIN
CG
A2
NEW PARTITION
B WINDOW OPENING (SHEET A601)
INTERIOR ELEVATION (SHEETS A104 thru 106)
WALL PROTECTIONWP
WALL MOUNTED FIRE EXTINGUISHERFE
A101
FLOOR PLAN - 1ST & 2ND
1/8" = 1'-0"A101 1 1st Floor Plan - New PACT Clinic
1/8" = 1'-0"A101 2 2nd Floor Plan - New HVAC Penthouse
KEY PLAN - FIRST FLOOR
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Consultant:
5190 Canal Boulevard, Suite 201 New Orleans, LA 70124 (504)835-8013
LACHIN
Architects, apc
Architecture . Planning . Project Management
RENOVATION OF PC BLUE FOR
WOMENS HEALTH
1500 E. Woodrow Wilson Dr. Jackson, MS
586-22-102
2/20/2025 MGL TAC
FINAL SUBMISSION
FULLY SPRINKLERED
Revisions: Date:
HWP HORIZONTAL HEATING WATER PUMPS
ABBREVIATIONS
VFMD VARIABLE FREQUENCY MOTOR DRIVES
AHU AIR HANDLING UNIT
HX HOT WATER HEAT EXCHANGE
CC CRASH CART
GENERAL NOTES
CONTRACTOR SHALL VERIFY EXISTING CONDITIONS.
DIMENSIONS ARE TO FINISH UNLESS OTHERWISE NOTED.
ANY DIMENSIONAL DISCREPANCIES BETWEEN DRAWING
DIMENSIONS AND EXISTING FIELD CONDITIONS SHALL BE
BROUGHT TO THE ATTENTION OF THE COR IMMEDIATELY.
SIGNAGE LOCATIONS ARE IDENTIFIED ON SHEET A103.
SYSTEMS FURNITURE AND DESK DIVIDERS SHOWN IN “PACT TEAM
AREA 105” ARE VA PROVIDED AND CONTRACTOR INSTALLED. SEE
ELECTRICAL FOR POWER CONNECTION LOCATIONS.
COORDINATE FURNITURE ARRANGEMENT WITH COR PRIOR TO
INSTALLATION.
SEE SHEET A602 FOR PARTITION TYPES.
FLOOR & CEILING PENETRATIONS THAT ARE ABANDONED SHALL BE
REPAIRED TO MAINTAIN 2 HOUR SEPARATION REQUIREMENTS.
DUCT & PIPE PENETRATIONS THROUGH FLOOR & CEILING SHALL BE
CAULKED WITH FIRE RATED SEALANT TO MAINTAIN 2 HOUR
SEPARATION.
1.
2.
3.
4.
6.
7.
5.
8.
9.
AutoCAD SHX Text 18'-0"
AutoCAD SHX Text 20'-0"
AutoCAD SHX Text 20'-0"
AutoCAD SHX Text 20'-0"
AutoCAD SHX Text 21'-6"
AutoCAD SHX Text 19'-2"
AutoCAD SHX Text 20'-0"
AutoCAD SHX Text 19'-6"
AutoCAD SHX Text 10'-6"
AutoCAD SHX Text 90'-8"
AutoCAD SHX Text 9'-11"
AutoCAD SHX Text 10'-4"
AutoCAD SHX Text 49'-4"
AutoCAD SHX Text 41'-3 1/8"
AutoCAD SHX Text 98'-1 1/2"
AutoCAD SHX Text
EXIST. RF-1
AutoCAD SHX Text
HWP 1
AutoCAD SHX Text
HWP 2
AutoCAD SHX Text
HX-1
AutoCAD SHX Text
HX-2
AutoCAD SHX Text
VFMD 1
AutoCAD SHX Text
VFMD 2
AutoCAD SHX Text
COPY
AutoCAD SHX Text
FILE
AutoCAD SHX Text
FILE
AutoCAD SHX Text
FILE
AutoCAD SHX Text
FILE
AutoCAD SHX Text
ICE
AutoCAD SHX Text
REF.
AutoCAD SHX Text S
AutoCAD SHX Text
MICROWAVE ABOVE
AutoCAD SHX Text
PYXIS
AutoCAD SHX Text U.C.
AutoCAD…
This is the start of the file's text. The full file is on GovTribe.