This document is an architectural and structural set of design drawings for a renovation project at the G.V. (Sonny) Montgomery VA Medical Center in Jackson, Mississippi. The project involves renovating approximately 6,850 square feet of space in the PC Blue area for a Women's Health PACT (Patient-Aligned Care Team) Clinic, with a total project duration of 540 calendar days. The renovation includes comprehensive architectural, mechanical, electrical, plumbing, and structural work across multiple floor levels, with specific focus on creating new medical spaces including exam rooms, reception areas, staff spaces, and a mechanical penthouse.

The solicitation is exclusively set aside for Service-Disabled Veteran-Owned Small Businesses (SDVOSB), with a requirement that at least 15% of contract personnel costs be spent on employees of eligible SDVOSB concerns. The project involves completely renovating the existing space while maintaining medical center operations, adhering to JCAHO, NFPA, ICARA, OSHA, and life safety requirements. Key design elements include new partitions, ceiling systems, medical equipment spaces, fire-rated assemblies, and specialized medical room configurations. The anticipated solicitation release date is 12/12/2025, with a firm-fixed price contract expected to be awarded following a Request for Proposals (RFP) process.

View the file

Other files

Show all 22

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

GENERAL NOTES APPLICABLE TO ALL DRAWINGS FOR

THIS PROJECT

1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

11.

ALL NOTES ON ALL DRAWINGS PERTAIN TO THE CONTRACTOR.

NO SMOKING IN AREAS OTHER THAN OFFICIALLY MARKED AS SMOKING AREA WILL BE PERMITTED ON VA

PREMISES.

THE CONTRACTOR SHALL BE PREPARED TO STOP ANY WORK AND CLEAR UP THE WORK AREA IF SO ASKED

IN MEDICAL SITUATIONS REQUIRING SUCH ACTION.

ALL TOOLS AND MATERIAL USED IN THE PROJECT SHALL BE PROPERLY SECURED AT ALL TIMES BY THE CONTRACTOR TO REDUCE THE POSSIBILITY OF ANY OF THESE TOOLS BEING A HAZARD TO PATIENTS, VISITORS OR STAFF.

ALL VA PROPERTY THAT IS NOT PERMANENTLY REMOVED FROM VA PREMISES UNDER THIS PROJECT WHICH IS DAMAGED BY CONSTRUCTION OF THIS PROJECT, SHALL BE REPLACED OR REPAIRED TO MATCH OR

EXCEED THE QUALITY THAT EXISTED BEFORE THE DAMAGE.

THE CONTRACTOR, AT HIS EXPENSE WILL BE RESPONSIBLE FOR TRAINING EACH MEMBER OF HIS WORK FORCE ON VA POLICIES FOR ON-SITE WORK BEFORE ANY MEMBER WILL BE ALLOWED TO PERFORM WORK ON VA PREMISES. BACKGROUND CHECKS WILL BE REQUIRED ON ALL EMPLOYEES AND ALL EMPLOYEES

MUST BE BADGED IN ACCORDANCE WITH VA POLICE DEPARTMENT AND THE VA.

ABSOLUTELY NO VA TOOLS, MATERIALS OR EQUIPMENT WILL BE LOANED OR GIVEN BY THE VA TO ANY

MEMBER OF THE CONTRACTOR’S WORK FORCE AT ANY TIME.

ANY SMOKE DETECTORS HAVING ANY POTENTIAL FOR EXPOSURE TO CONSTRUCTION SMOKE, DUST AND DEBRIS SHALL BE SUITABLY ATTENDED TO IN ORDER TO PREVENT ACCIDENTAL ALARM. ALL SUCH ACTION MUST BE FIRST COORDINATED AND CLEARED WITH THE COR AND THE VA SAFETY OFFICER. ALL FIRE ALARM DEVICES SHALL BE ACTIVE WHEN CONTRACTOR’S FORCES ARE VACANT FROM ANY AREA AT ANY

TIME.

CONTRACTOR SHALL COORDINATE WITH THE COR AND CONTRACTING OFFICER.

SEE SPECIFICATION SECTION 01 35 26 SAFETY REQUIREMENTS.

GENERAL HOURS OF WORK SHALL BE RESTRICTED FROM 0730 TO 1600 MONDAY THRU FRIDAY EXCEPT FEDERAL HOLIDAYS. CONTRACTOR MAY SUBMIT A REQUEST FOR OFF-HOUR WORK A MINIMUM 72 HOURS IN ADVANCE. APPROVAL IS AT SOLE DISCRETION OF THE VA. WHEN SOME NIGHT/WEEKEND WORK IS

REQUIRED, COORDINATE WITH PHASING PLAN SHEET A101.

VA APPROVAL

DEPARTMENT SIGNATURES

MEDICAL CENTER DIRECTOR

MEDICAL CENTER ASSOCIATE DIRECTOR

CHIEF OF STAFF

ASSOCIATE DIRECTOR OF PATIENT CARE

DEPUTY CHIEF OF STAFF /

PHYSICAL MEDICINE & REHAB

SERVICE REPRESENTATIVE

SAFETY OFFICE

PROJECT MANAGER

INFECTION PREVENTION

ENGINEERING CHIEF

DEPARTMENT OF VETERANS AFFAIRS

G.V. (SONNY) MONTGOMERY VAMC

JACKSON, MS

AD100 ARCHITECTURAL DEMO FLOOR PLAN & RCP

AD101 ARCHITECTURAL DEMO PLANS AND RCP

A101 FLOOR PLAN - 1ST & 2ND

A102 A103

REFLECTED CEILING PLANS

ENLARGED FLOOR PLANS & INTERIOR ELEVATIONS

A201 PENTHOUSE ELEVATIONS, SECTIONS & ROOF PLAN

A502 SIGNAGE, MILLWORK DETAILS & MISCELLANEOUS DETAILS

A601 OPENING SCHEDULES & DETAILED DOOR SECTIONS

G001 COVER SHEET

G002 PROJECT DATA

LS101 LIFE SAFETY PLAN

Project Location

INDEX OF DRAWINGS

ELECTRICAL

ARCHITECTURAL

PROJECT NO. 586-22-102

RENOVATION OF PC BLUE FOR PACT

VICINITY MAP

MD101 BASEMENT FLOOR PLAN - CONTROLS DEMOLITION

MD102 FIRST FLOOR PLAN - HVAC - DEMOLITION

MD103 FIRST FLOOR PLAN - EXHAUST AND HEATING WATER PIPING - DEMOLITION

MD104 FIRST FLOOR PLAN - LARGE SCALE CHILLED WATER - DEMOLITION

MD105 FIRST FLOOR PLAN - LARGE SCALE MECHANICAL ROOM CHILLED WATER SCHEMATIC - DEMOLITION

MD106 FIRST FLOOR PLAN - LARGE SCALE HEATING WATER - DEMOLITION

MD107 FIRST FLOOR PLAN - LARGE SCALE MECHANICAL ROOM HEATING WATER SCHEMATIC - DEMOLITION

MD108 FIRST FLOOR PLAN - LARGE SCALE STEAM PIPING - DEMOLITION

MD109 FIRST FLOOR PLAN - LARGE SCALE MECHANICAL ROOM STEAM PIPING SCHEMATIC - DEMOLITION

MH001 MECHANICAL SYMBOLS AND ABBREVIATIONS

MH002 MECHANICAL NOTES

MH101 BASEMENT FLOOR PLAN - CONTROLS - NEW WORK

MH102 FIRST FLOOR PLAN - HVAC - NEW WORK

MH103 FIRST FLOOR PLAN - HEATING & CHILLED WATER - NEW WORK

MH104 FIRST FLOOR PLAN - EXHAUST - NEW WORK

MH105 FIRST FLOOR PLAN - LARGE SCALE PENTHOUSE HVAC - NEW WORK

MH106 FIRST FLOOR PLAN - LARGE SCALE MECHANICAL ROOM HEATING WATER PIPING - NEW WORK

MH107 FIRST FLOOR PLAN - LARGE SCALE MECHANICAL ROOM STEAM PIPING - NEW WORK

MH108 FIRST FLOOR PLAN - LARGE SCALE PENTHOUSE HYDRONIC PIPING - NEW WORK

CAMPUS MAP

Project Location

E000 ELECTRICAL LEGEND AND NOTES

E001 ELECTRICAL DETAILS

E002 ELECTRICAL DETAILS

E101 ELECTRICAL DEMOLITION PLAN - BASEMENT

E102 ELECTRICAL DEMOLITION PLAN - FIRST FLOOR

E201 NEW LIGHTING PLAN - FIRST FLOOR

E202 NEW POWER AND COMM. PLAN - FIRST FLOOR

E203 NEW FIRE ALARM AND MECH SYSTEMS PLAN - BASEMENT

E204 NEW FIRE ALARM AND MECH SYSTEMS PLAN - FIRST FLOOR

E205 NEW ELECTRICAL PLAN - MECH. PENTHOUSE

G001

COVER SHEET

S100 STRUCTURAL GENERAL NOTES

S101 FLOOR PLAN - 1ST & 2ND

S102 DETAILS

STRUCTURAL

MH301 MECHANICAL DETAILS

MH302 MECHANICAL DETAILS

MH303 MECHANICAL DETAILS

MH304 MECHANICAL DETAILS

MH305 MECHANICAL DETAILS

MH306 MECHANICAL DETAILS

MH307 MECHANICAL DETAILS

MH308 MECHANICAL DETAILS

MH401 MECHANICAL DETAILS

MH402 MECHANICAL DETAILS

MH403 MECHANICAL DETAILS

MH501 MECHANICAL DETAILS

MH502 MECHANICAL DETAILS

MH503 MECHANICAL DETAILS

MECHANICAL

PD101 FIRST FLOOR PLAN - PLUMBING WASTE - DEMOLITION

PD102 FIRST FLOOR PLAN - PLUMBING SUPPLY - DEMOLITION

PL001 PLUMBING SYMBOLS, NOTES, & ABBREVIATIONS

PL101 FIRST FLOOR PLAN - PLUMBING WASTE - NEW WORK

PL102 FIRST FLOOR PLAN - PLUMBING SUPPLY - NEW WORK

PL103 FIRST FLOOR PLAN - FIRE PROTECTION - NEW WORK

PL301 PLUMBING DETAILS & SCHEDULES

PLUMBING

PD103 FIRST FLOOR PLAN - FIRE PROTECTION - DEMOLITION

PD104 FIRST FLOOR PLAN - MEDICAL GAS - DEMOLITION

AD102

LS102 LIFE SAFETY PLAN - OVERALL FIRST LEVEL

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

Consultant:

5190 Canal Boulevard, Suite 201 New Orleans, LA 70124 (504)835-8013

LACHIN

Architects, apc

Architecture . Planning . Project Management

RENOVATION OF PC BLUE FOR

WOMENS HEALTH

1500 E. Woodrow Wilson Dr. Jackson, MS

586-22-102

2/20/2025 MGL TAC

FINAL SUBMISSION

FULLY SPRINKLERED

Revisions: Date:

A202 PENTHOUSE DETAILS

WALL TYPES - SELECTIVE DEMOLITION

MECHANICAL CON'T.

S103 DETAILS

A100 FIRST FLOOR PHASING PLAN

A104

ENLARGED FLOOR PLANS & INTERIOR ELEVATIONS

E301 PANEL BOARD SCHEDULES

A602 ROOM FINISH SCHEDULE & PARTITION TYPES

A105

ENLARGED FLOOR PLANS & INTERIOR ELEVATIONS

FIRST FLOOR SIGNAGE PLAN

A106

A503 MILLWORK DETAILS

PD105 FIRST FLOOR PLAN - LARGE SCALE STORM WATER - DEMO

PL104 LARGE SCALE STORM WATER - NEW WORK

PL401 PLUMBING SCHEDULES

AFF ABOVE FINISHED FLOOR

ACT ACOUSTICAL CEILING TILE

ALUM ALUMINUM

BD BOARD

BOT BOTTOM

BUR BUILT-UP ROOFING

CIP CAST-IN-PLACE

CEM CEMENT

CTR CENTER

CL CENTER LINE

CT CERAMIC TILE

CFCI CONTRACTOR FURNISHED, CONTRACTOR INSTALLED

CO CLEANOUT, CASED OPENING

COL COLUMN

CONC CONCRETE

COR CONTRACTING OFFICER OF RECORD

CJ CONTROL JOINT

DET DETAIL

DIA DIAMETER

DIM DIMENSION

DR DOOR

DS DOWNSPOUT

EWC ELECTRIC WATER COOLER

EQ EQUAL

EXP EXPANSION

EJ EXPANSION JOINT

FRP FIBER REINFORCED POLYESTER

FIN FLR FINISH FLOOR

FE FIRE EXTINGUISHER

FD FLOOR DRAIN

GA GAUGE

GALV GALVANIZED

GB GRAB BAR

GYP GYPSUM

HVAC HEATING, VENTILATING & AIR CONDITIONING

HEPA HIGH EFFICIENCY PARTICULATE AIR

HM HOLLOW METAL

INT INTERIOR

LAM LAMINATE

LAV LAVATORY

MO MASONRY OPENING

MECH MECHANICAL

MTL METAL

MOD BIT MODIFIED BITUMEN

MS MOP SINK

NIC NOT IN CONTRACT

NTS NOT TO SCALE

OC ON CENTERS

OPP OPPOSITE

O/O OUT TO OUT

OA OVERALL

OH OVERHANG

PT PAINT

PNL PANEL

PTD PAPER TOWEL DISPENSER

PLAS PLASTER

PLAM PLASTIC LAMINATE

PLBG PLUMBING

PLYWD PLYWOOD

PL PROPERTY LINE

QT QUARRY TILE

RA RETURN AIR

REV REVISION

RTU ROOF TOP UNIT

RO ROUGH OPENING

SAB SOUND ATTENUATION BATTS

SND SANITARY NAPKIN DISPENSER

SJ SCORED JOINT

SS SERVICE SINK, STAINLESS STEEL

SIM SIMILAR

SD SOAP DISPENSER

SC SOLID CORE

TER TERRAZZO

TPD TOILET PAPER DISPENSER

TO_ TOP OF_

UNO UNLESS NOTED OTHERWISE

UR URINAL

VFCI VA FURNISHED, CONTRACTOR INSTALLED

VFVI VA FURNISHED, VA INSTALLED

VAV VARIABLE AIR VOLUME

VTR VENT THROUGH ROOF

VCT VINYL COMPOSITION TILE

WC WATER CLOSET

WR WEATHER RESISTANT

WD WOOD

2010: ADA STANDARDS FOR ACCESSIBLE DESIGN.

OCCUPATIONAL SAFETY AND HEALTH STANDARDS, U.S. DEPARTMENT OF LABOR

(OSHA): 29 CFR, PART 1926, AS AMENDED, INCLUDING FINAL RULE.

2023: NFPA 241, CONSTRUCTION, ALTERATION AND DEMOLITION OPERATIONS.

2018: INTERNATIONAL BUILDING CODE, NO LOCAL AMENDMENTS.

2022: NFPA 70, NATIONAL ELECTRICAL CODE.

2017: VA BARRIER FREE DESIGN STANDARD REV. 11/1/18

2018: IPC INTERNATIONAL PLUMBING CODE, NO LOCAL AMENDMENTS.

2018: IMC INTERNATIONAL MECHANICAL CODE, NO LOCAL AMENDMENTS.

ICC / ANSI 117.1 - 2009 AMERICAN NATIONAL STANDARD FOR ACCESSIBLE AND

USEABLE BUILDINGS AND FACILITIES.

2024: NFPA 101, LIFE SAFETY CODE FOR LOCAL JURISDICTION COMPLIANCE.

2024: NFPA 101, LIFE SAFETY CODE FOR FEDERAL CERTIFICATION. *(COMPLY WITH THE

MOST RESTRICTIVE REQUIREMENTS IF THESE TWO NFPA 101 STANDARDS

CONFLICT).

2024: NFPA 99, HEALTH CARE FACILITIES.

2018: GUIDELINES FOR DESIGN AND CONSTRUCTION OF HEALTH CARE FACILITIES,

FACILITIES GUIDELINES INSTITUTE.

JOINT COMMISSION FOR ACCREDITATION OF HEALTHCARE ORGANIZATIONS

(JCAHO), STANDARD EC5.50, INTERIM LIFE SAFETY MEASURES (ILSM), AS

PUBLISHED IN THE COMPREHENSIVE ACCREDITATION MANUAL FOR HOSPITALS:

THE OFFICIAL HANDBOOK (CAMH), 2004 EDITION.

2022: NFPA 13, STANDARD FOR THE INSTALLATION OF SPRINKLER SYSTEMS.

2022: NFPA 72, NATIONAL FIRE ALARM AND SIGNALING CODE.

FIRE PROTECTION OFFICE OF SAFETY, HEALTH AND ENVIRONMENTAL

COMPLIANCE (10NA8), 7th EDITION, Dec. 2015

2023: FIRE PROTECTION DESIGN MANUAL, Ninth Edition

GENERAL NOTES

A. DRAWINGS AND SPECIFICATIONS ARE INTENDED TO BE

COMPLEMENTARY. SPECIFIC INFORMATION MAY BE FOUND IN

EITHER OR BOTH.

B. CONTRACTOR TO VISIT THE SITE PRIOR TO BIDDING AND

BECOME FAMILIAR WITH ALL ASPECTS OF THE WORK. FAILURE

TO INSPECT THE SITE OR FULLY ACQUAINT HIMSELF WITH THE

PLANS AND SPECIFICATIONS PRIOR TO BIDDING WILL NOT

RELIEVE THE CONTRACTOR OF PERFORMANCE OF ANY OF THE

WORK REQUIRED BY EXISTING CONDITIONS OR THE INTENT OF

THE CONTRACT DOCUMENTS. BID SUBMITTAL SHALL REFLECT

ANY EXTRANEOUS CONDITIONS THAT MAY OCCUR.

C. LAYOUT OF WORK

1. EXERCISE PROPER PRECAUTION TO VERIFY ALL EXISTING

CONDITIONS AND LAYOUT OF THE WORK. CONTRACTOR TO

NOTIFY THE CONTRACTING OFFICER OF ANY DISCREPANCIES

IMMEDIATELY.

.2 CONTRACTOR IS RESPONSIBLE FOR ANY ERROR

RESULTING FROM FAILURE TO EXERCISE SUCH PRECAUTION.

SUCH ERROR WILL NOT BE CONSIDERED SUBSEQUENTLY AS A

BASIS FOR EXTRA COMPENSATION.

3. GC TO LAYOUT WORK AND BE RESPONSIBLE FOR ALL

LINES, MEASUREMENTS OF THE BUILDING AND OTHER WORK

EXECUTED UNDER CONTRACT.

4. SHOULD A CONTRACTOR FIND DISCREPANCIES IN, OR

OMISSIONS FROM THE DRAWINGS OR SPECIFICATIONS OR

SHOULD HE BE IN DOUBT AS TO THEIR MEANING, HE SHOULD

NOTIFY THE CONTRACTING OFFICER AT ONCE.

D. EXAMINATION

1. ANY DISCREPANCIES, ERRORS OR OMISSIONS

DISCOVERED IN THE CONTRACT DOCUMENTS BY THE

CONTRACTOR SHALL BE BROUGHT TO THE ATTENTION OF THE

CONTRACTING OFFICER BEFORE PROCEEDING WITH RELATED

WORK, OTHERWISE THE CORRECTION OF SUCH ITEMS IS THE

RESPONSIBILITY OF THE CONTRACTOR.

E. CODES AND STANDARDS

1. ALL WORK, MATERIALS AND INSTALLATION SHALL BE IN

STRICT ACCORDANCE'S WITH ALL VA AND NATIONAL BUILDING

CODES, LATEST EDITION.

2. DESIGN LOADS AND CODE RESTRICTIONS FOR ALL DESIGN

CONSIDERATIONS SHALL CONFORM TO THE VA AND NATIONAL

GOVERNING CODES.

F. DEMOLITION

1. THIS SECTION IS INCLUDED FOR GENERAL REFERENCE OF

DEMO WORK BY THE GENERAL CONTRACTOR.

2. DEMOLITION INCLUDES OBJECTS IDENTIFIED BY THE

CONTRACT DOCUMENTS AND SPECIFICATIONS.

3. ARRANGE WITH THE OWNER A CONVENIENT TIME TO

PERFORM DEMOLITION WORK.

4. THE CONTRACTOR SHALL REPAIR, RESTORE AND

REPLACE PORTIONS OF CONSTRUCTION WHERE INDICATED ON

DRAWINGS OR AS REQUIRED TO INSTALL THE WORK. ANY

PORTIONS OF THE CONSTRUCTION WHICH ARE CRACKED,

SPALLED, BROKEN, MISSING OR OUT OF LINE OR ADJUSTMENT,

MECHANICALLY OR STRUCTURALLY UNSOUND OR UNSAFE,

SHALL BE REMOVED, REPLACED, RESTORED OR

SATISFACTORILY REPAIRED.

5. REMOVE, PROTECT AND REINSTALL ALL ITEMS AFFECTED BY

CONSTRUCTION THAT ARE NOT INDICATED TO BE REMOVED

INCLUDING, BUT NOT LIMITED TO SPEAKERS, WIFI AND OTHER

EXISTING MISCELLANEOUS DEVICES.

G. ALL WORK SHALL BE PERFORMED IN CONFORMANCE WITH

APPLICABLE STANDARD SPECIFICATIONS. WORKMANSHIP AND

MAINTAINING STANDARDS OF QUALITY SHALL BE THE

RESPONSIBILITY OF THE GENERAL CONTRACTOR. THE

GENERAL CONTRACTOR SHALL PROVIDE ALL WORK SHOWN IN

THESE CONTRACT DOCUMENTS AND IS REQUIRED TO PROVIDE

A COMPLETE, FINISHED, FULLY OPERABLE INSTALLATION,

UNLESS OTHERWISE NOTED. IT IS THE RESPONSIBILITY OF THE

CONTRACTOR AND EACH OF THE SUBCONTRACTORS TO BE

ACQUAINTED WITH ALL PROJECT REQUIREMENTS AND BUILDING

STANDARDS REGARDLESS OF WHETHER THEY HAVE BEEN

SPECIFICALLY REFERENCED IN THE DOCUMENTS OR NOT.

I. CONTRACTOR SHALL COORDINATE WITH THE CONTRACTING

OFFICER THE SELECTION AND APPROVAL OF ALL SUBSTITUTED

ITEMS PRIOR TO SUBMISSIONS OF THE BID. IT IS EACH

CONTRACTOR'S RESPONSIBILITY TO ENSURE AND TO

DEMONSTRATE THAT ALL SUBSTITUTIONS USED IN THE WORK

COMPLY WITH THE CONTRACT DOCUMENTS. SHOULD A

SUBSTITUTED PRODUCT FAIL TO PERFORM FOR ANY REASON,

WHERE THE ORIGINALLY SPECIFIED PRODUCT WOULD HAVE

PERFORMED PROPERLY, THE CONTRACTOR SHALL PERFORM

ALL WORK NECESSARY TO INCORPORATE THE ORIGINALLY

SPECIFIED PRODUCT AT NO ADDITIONAL COST.

J. EACH SUBCONTRACTOR SHALL CHECK AND VERIFY PRIOR TO

BID, ALL PLANS, SPECIFICATIONS, EXISTING CONDITIONS AND

DIMENSIONS AT THE JOB SITE AND SHALL NOTIFY THE

CONTRACTING OFFICER OF ANY DISCREPANCIES IN OR

BETWEEN THE CONTRACT DOCUMENTS AND THE FIELD

CONDITIONS PRIOR TO COMMENCING THE WORK.

K. DO NOT TAKE SCALED MEASUREMENTS FROM THESE

DRAWINGS. CONSULT WITH THE COR FOR MISSING DIMENSIONS.

L. EACH CONTRACTOR SHALL ANALYZE THE CONTRACT

DOCUMENTS AND IMMEDIATELY REPORT ANY DISCREPANCIES

TO THE CONTRACTING OFFICER PRIOR TO BID. EACH

CONTRACTOR SHALL BE REQUIRED TO CORRECT ANY

DEFECTIVE WORK CAUSED BY WORK DONE AS A RESULT OF

INCONSISTENCIES OR DISCREPANCIES IN THE DRAWINGS WHEN

CLARIFICATION FROM THE CONTRACTING OFFICER HAS NOT

BEEN SOUGHT.

M. ARCHITECTURAL, PLUMBING, ELECTRICAL, MECHANICAL AND

ALL OTHER DOCUMENTS SHALL BE REVIEWED AND

COORDINATED BY THE CONTRACTOR. REPORT ANY

INCONSISTENCIES WITHIN THE DOCUMENTS TO THE

CONTRACTING OFFICER.

N. CONTRACTOR SHALL PROVIDE THE COR WITH A SET OF

REPRODUCIBLE AS-BUILT DOCUMENTS AND DVD AT THE

PROJECT CLOSE-OUT PER SPECIFICATIONS.

O. AS SCOPE AND PERFORMANCE DOCUMENTS, THE DRAWINGS

AND SPECIFICATIONS INDICATE THE MINIMUM WORK REQUIRED

FOR THE PERFORMANCE AND COMPLETION OF BUILDING

ASSEMBLIES. THE CONTRACTOR SHALL BE SOLELY

RESPONSIBLE FOR THE FABRICATION AND INSTALLATION OF ALL

MISCELLANEOUS METAL ITEMS INDICATED, DESCRIBED OR

IMPLIED ON ALL DRAWINGS. MISCELLANEOUS METAL ITEMS,

WITHIN OR REQUIRED TO SUPPORT AN ASSEMBLY, WHETHER

OR NOT ATTACHED TO THE STRUCTURE, ARE THE

RESPONSIBILITY OF THE GENERAL CONTRACTOR AND HIS

SUBCONTRACTORS WHETHER THEY ARE SHOWN OR NOT

SHOWN ON THE ARCHITECTURAL, STRUCTURAL, CIVIL,

MECHANICAL OR ELECTRICAL DRAWINGS. SUCH ASSEMBLIES

INCLUDE BUT ARE NOT LIMITED TO EXTERIOR AND INTERIOR

WALL, CEILING, PARTITION, ROOF, MECHANICAL AND

ELECTRICAL ASSEMBLIES AS WELL AS ALL SIMILAR

ASSEMBLIES. ANY MISCELLANEOUS METAL ITEMS INDICATED

ON THE ARCHITECTURAL DRAWINGS AND NOT SHOWN ON

STRUCTURAL DRAWINGS SHALL BE A MINIMUM OF L3x3x1/2", C7x9.8, 3/8" PLATE OR TS4x4x3/8" UNLESS OTHERWISE

APPROVED BY THE STRUCTURAL ENGINEER. STEEL BEAMS

SHOWN ON THE ARCHITECTURAL DRAWINGS BUT NOT ON THE

STRUCTURAL DRAWINGS SHALL BE ASSUMED TO BE A MEDIUM

WEIGHT BEAM CONNECTED FROM COLUMN TO COLUMN WITH A

SIZE CONSISTENT WITH THE SCALED HEIGHT OF THE BEAM.

P. ALL CONTRACTORS WORKING IN THE HOSPITAL WILL HAVE

TO GO THROUGH A BASIC BACKGROUND CHECK. THE PROCESS

WILL REQUIRE FINGERPRINTING AND APPROXIMATELY THREE

WEEKS OF PROCESSING TIME BEFORE WORKERS /

CONTRACTORS CAN ENTER THE PROJECT AREA.

NORTH ARROW

Room name

101ROOM TAG

EQUIPMENT TAG

COLUMN GRID TAG

LEVEL ANNOTATION

BUILDING SECTION

VIEW / DETAIL TITLE

PARTITION TAG

DOOR TAG

CENTERLINE

REVISION CLOUD

BREAK LINE

SPOT ELEVATION

ENLARGED PLAN / DETAIL REFERENCE

x'-x"

BUILDING ELEVATION

WALL SECTION

REVISION

INTERIOR ELEVATION

GLAZING TYPE TAG

SECTION / DETAIL

FLOOR LINES IN EXTERIOR ELEVATION; CENTER

PROPERTY LINE, BOUNDARY LINES

MATCH LINE

FX

BX

WX

WX

WX WXROOM FINISH TAG

FLOORWALL FINISH

BASE

FINISH MATERIAL TAG XX-##

PARTITION WITH CORNER GUARD

PARTITION WITH WALL GUARD

PARTITION WITH END CAP

PARTITION WITH ADDITIONAL BRACING

A203

A1

DRAWING BLOCK TITLE

SCALE: 1"=1'-0"

Name Elevation

A001

A

WOOD

WOOD FINISH

ALUMINUM

STEEL

EARTH

GYPSUM - PLASTER

MASONRY -

CONCRETE BLOCK

RIGID INSULATION

BATT INSULATION

PLYWOOD

CONCRETE

1.

2.

3.

4.

5.

6.

7.

8.

9.

THE RENOVATION OF PC BLUE TO PACT PROJECT INCLUDES RENOVATION OF

APPROXIMATELY 6,850 SQUARE FEET OF AREA WITHIN THE EXISTING VA MEDICAL

CENTER.

THE WORK GENERALLY INCLUDES BUT IS NOT LIMITED TO:

INSTALLATION OF TEMPORARY PARTITIONS, DOOR AND OTHER PROTECTIVE

MEASURES TO ISOLATE THE CONSTRUCTION AREA. PROVIDE NEGATIVE

PRESSURE FOR DUST CONTROL AND ACOUSTICAL SEPARATION SO AS NOT TO

DISRUPT THE ONGOING ACTIVITIES IN THE HOSPITAL.

TEMPORARY MODIFICATIONS OR RELOCATION OF EXISTING SYSTEMS TO

PRESERVE EXISTING LIFE SAFETY FEATURES SUCH AS EXITS, SPRINKLER

SYSTEMS, ALARM SYSTEMS AND OTHER SPECIAL SYSTEMS.

DEMOLITION OF THE EXISTING CONSTRUCTION IN THE FOOTPRINT OF THE

PROJECT SITE AND SAFE REMOVAL AND DISPOSAL OF DEBRIS.

INSTALLATION OF NEW PARTITION SYSTEM, CEILING SYSTEM AND ALL

PLUMBING, MECHANICAL AND ELECTRICAL SYSTEMS AS DEFINED IN THE

DOCUMENTS TO INTERFACE WITH EXISTING SYSTEMS.

PHASING OF THE WORK SUCH THAT THE ABOVE CEILING WORK OUTSIDE OF

THE PROJECT SITE AND SIMILAR WORK OUTSIDE OF THE PROJECT AREA BE

SCHEDULED TO MINIMIZE DISRUPTION AND DOWN-TIME TO AREAS OUTSIDE OF

THE PROJECT SITE.

INSTALLATION OF ALL ARCHITECTURAL FINISHES AND BUILT-IN EQUIPMENT.

FINAL CLEANING AND REMOVAL OF ALL TEMPORARY PARTITION SYSTEMS AND

PROTECTIVE MEASURES. REPAIR OR RESTORATION OF ANY EXISTING

FINISHES OR CONSTRUCTION DAMAGED DURING THE CONSTRUCTION

PROCESS.

FINAL TESTING OF NEW SYSTEMS, TRAINING AND DEMONSTRATION OF NEW

SYSTEMS AND SUBMISSION OF CLOSE-OUT DOCUMENTS. CLOSE-OUT

DOCUMENTS SHALL BE SUBMITTED TO THE OWNER NO LATER THAN 30 DAYS

FOLLOWING THE FINAL ACCEPTANCE OF THE PROJECT.

MODIFICATIONS TO EXISTING HVAC, PLUMBING, ELECTRICAL, FIRE

PROTECTION AND SPECIAL SYSTEMS.

GENERAL SCHEDULING NOTE TO CONTRACTOR

1.

2.

WORK FOR EACH AREA IS TO BE COORDINATED WITH THE COR OR PROJECT ENGINEER.

THE BUILDING SHALL REMAIN OCCUPIED THROUGHOUT CONSTRUCTION. WORK SHALL

BE ARRANGED TO ALLOW AS LITTLE INTERRUPTION AND INCONVENIENCE AS POSSIBLE.

THE CONTRACTOR IS TO SUBMIT A WRITTEN SCHEDULE OF WORK TO THE COR FOR

APPROVAL WHICH DETAILS CONSTRUCTION START AND CONSTRUCTION COMPLETION

FOR EACH AREA. SCHEDULE OF WORK SHALL BE SUBMITTED AND APPROVED BY THE

COR PRIOR TO STARTING ANY WORK ACTIVITIES

CLIENT

PROJECT NAME

PROJECT ADDRESS

OCCUPANCY TYPE

PROJECT GROSS FLOOR

AREA

HEIGHT ABOVE GROUND

NUMBER OF STORIES

TYPE OF CONSTRUCTION

VETERANS ADMINISTRATION

Project Name

1500 E. WOODROW WILSON AVE, JACKSON, MS

PROJECT DATA

6,850 SF

HEALTH CARE (NFPA)

INSTITUTIONAL I2 (IBC)

4 STORIES

TYPE 1A (IBC)

TYPE 1 (332)(NFPA)

MATERIAL SYMBOLS

G002

PROJECT DATA

GRAPHIC SYMBOLS

ABBREVIATIONS

CODES

PROJECT DESCRIPTION

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

Consultant:

5190 Canal Boulevard, Suite 201 New Orleans, LA 70124 (504)835-8013

LACHIN

Architects, apc

Architecture . Planning . Project Management

RENOVATION OF PC BLUE FOR

WOMENS HEALTH

1500 E. Woodrow Wilson Dr. Jackson, MS

586-22-102

2/20/2025 MGL TAC

FINAL SUBMISSION

FULLY SPRINKLERED

Revisions: Date:

A

1 2 3 4 5

B

C

D

E

F

FEC

FEC

FEC

FE

FEC

EXIT

EXIT

ELEVATOR

LOBBY

MPE 1

MPE 5

MPE 6

RECEPTION

GPR

SUR CUR CHIEF

MECHANICAL

LACTATION

SWO

MEDICATION

DIETICIAN

PHARM

HAC

STORAGE 5

NURSE

TOILET

ST

OR

AG

E

EHRM

PACT TEAM AREA

STORAGE 1

MPE 4

MPE 3

MPE 2 P. TOILET 1 P. TOILET 2

STAFF

TOILET

NURSE

BREAK ROOM

SUPPLY

GYNO

HALL 2

HALL 1

MHO

EXIT

EXIT

ELEV

ELEV

STORAGE 4

Common Path of Travel - 86'

STAIR 1

STAIR 2

WAITING

Tra ve l D ist an ce

8' to

Ex it

Travel Distance = 129' to Exit

CO

RR

ID

OR

B

MEP CHASE

CORRIDOR A

CO

RR

ID

OR

A

CORRIDOR B

STORAGE 2

Common Path of Travel = 66'

Travel Distance = 173' to Exit

De ad

En d C orr ido r

De ad

En d C orr ido r

1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

11.

12.

13.

14.

15.

16.

17.

18.

19.

20.

21.

22.

ALL FIRE WALLS, FIRE BARRIERS, FIRE PARTITIONS & SMOKE BARRIERS AND SMOKE PARTITIONS OR ANY OTHER WALL REQUIRED TO HAVE PROTECTED OPENINGS OR PENETRATIONS SHALL BE EFFECTIVELY AND PERMANENTLY IDENTIFIED WITH SIGNS OR STENCILING. THE ARE TO BE LOCATED IN ACCESSIBLE CONCEALED FLOOR, FLOOR- CEILING OR ATTIC SPACES; BE LOCATED WITHIN 15 FEET OF THE END OF EACH WALL AND AT INTERVALS NOT EXCEEDING 30' MEASURED HORIZONTALLY ALONG THE WALL OR PARTITION; AND INCLUDE LETTERING NOT LESS THAN 3" IN HEIGHT WITH A MINIMUM 3/8" STROKE IN A CONTRASTING COLOR INCORPORATING THE SUGGESTED

WORDING. "FIRE AND/OR SMOKE BARRIER-PROTECT ALL OPENINGS" OR OTHER WORDING.

PROVIDE SURFACE MOUNTED LIGHT FIXTURES AT RATED CEILINGS, UNLESS NOTED/DETAILED OTHERWISE.

REFER TO ELECTRICAL DRAWINGS FOR STROBE, FIRE ALARM AND CARBON MONOXIDE DETECTORS, EMERGENCY LIGHTS, PULL STATIONS, FIRE PANEL LOCATIONS, OTHER

AUDIO AND VISUAL DEVICES, INCLUDING LOCATIONS AND MOUNTING HEIGHT.

PROVIDE CORRESPONDING RATED ACCESS PANEL AT RATED WALLS/CEILINGS. LATCHING AND FINISH TO BE AS SPECIFIED.

REFER TO CORRESPONDING ARCHITECTURAL DRAWINGS FOR WALL AND FLOOR DETAILS.

GC TO PROVIDE CORRESPONDING FIRE CAULK AT RATED WALLS.

SMOKE & DRAFT CONTROL - FIRE DOOR ASSEMBLIES SHALL ALSO MEET THE REQUIREMENTS FOR A SMOKE AND DRAFT CONTROL DOOR ASSEMBLY TESTED IN ACCORDANCE WITH UL1784. DOOR LOUVERS ARE PROHIBITED. INSTALLATION OF SMOKE DOORS SHALL BE IN ACCORDANCE WITH NFPA 105.

PER NFPA 101-8.3.4 GLAZING IN DOOR ASSEMBLIES - IN A 20-MINUTE FIRE DOOR ASSEMBLY, THE GLAZING MATERIAL IN THE DOOR ITSELF SHALL HAVE A MINIMUM FIRE- PROTECTION RATED GLAZING OF 20 MINUTES AND SHALL BE EXEMPT FROM THE HOSE STREAM TEST.

PROVIDE THROUGH-PENETRATION FIRESTOP SYSTEM AS REQUIRED PER THE FIRE RESISTANCE RATING OF THE WALL. REFER TO NFPA 101-8.3.5.

PENETRATIONS OF A FLOOR, FLOOR/CEILING ASSEMBLY OF THE CEILING MEMBRANE OR A ROOF/CEILING ASSEMBLY SHALL COMPLY WITH NFPA 101-8.3.5.

PROVIDE WALL MOUNTED EXIT SIGNS. LOCATE ABOVE ALL EXIT DOORS. REFER TO ELECTRICAL DRAWINGS FOR MOUNTING HEIGHTS AND MODELS.

WHERE AN AIR DUCT PENETRATES ONLY ONE FLOOR OR ONE FLOOR AND AN AIR-HANDLING EQUIPMENT PENTHOUSE FLOOR, AND THE AIR DUCT CONTAINS A FIRE DAMPER LOCATED WHERE THE DUCT PENETRATES THE FLOOR, AN AIR DUCT ENCLOSURE SHALL NOT BE REQUIRED.

FIRE DAMPERS, SMOKE DAMPERS, COMBINATION FIRE/SMOKE DAMPERS AND CEILING RADIATION DAMPERS LOCATION TO BE COORDINATED AT ALL SMOKE AND/OR FIRE RATED PARTITIONS. REFER TO CODE COMPLIANCE PLANS, ELECTRICAL DRAWINGS FOR WIRING DESIGN AND MECHANICAL DRAWINGS.

PORTABLE FIRE EXTINGUISHERS SHALL BE SELECTED, INSTALLED AND MAINTAINED IN ACCORDANCE NFPA 10. BASED ON THIS OCCUPANCY TYPE, CLASS A FOR ORDINARY(MODERATE) HAZARD OCCUPANCY TYPE 2-A FIRE EXTINGUISHERS ARE REQUIRED NO MORE THAN 75' APART AND ON EACH STORY PER TABLE 6.2.1.1 IN NFPA 10.

PROVIDE RECESSED FIRE EXTINGUISHERS AS INDICATED. MOUNT FIRE EXTINGUISHER IN OR WITHOUT CABINET AT 48" AFF TO THE HANDLE. REFER TO SPECIFICATIONS.

CONTRACTOR TO PROVIDE PORTABLE FIRE EXTINGUISHERS EVERY 75 ’ ON THE JOB SITE DURING CONSTRUCTION.

BUILDING UNDER EMERGENCY GENERATOR POWER AS WELL AS UPS. REFER TO OWNER PROVIDED INFORMATION FOR EXISTING SYSTEM REQUIREMENTS.

WHERE CONDUIT, CABLES, AND OTHER ELECTRICAL PROVISIONS PENETRATE RATED WALL AND FLOOR PENETRATIONS PROVIDE ASSEMBLIES CLASSIFIED WITH A UL DESIGNATION AND COMPLY WITH ALL APPLICABLE CODES AND CORRESPONDING TESTING. SUBMIT SUBMITTALS WITH INDICATED UL DESIGNATIONS FOR EACH CONDITION.

CONTRACTOR TO SEAL ALL VOIDS AT INTERSECTION OF PARTITIONS AND FLOOR OR SLAB CONDITIONS, BETWEEN PIPE SLEEVES, AND OTHER PENETRATIONS AT SMOKE

AND FIRE RATED WALL AND FLOOR PENETRATIONS.

NO PENETRATIONS UNRELATED FOR THE PURPOSE OF THE EXIST ACCESS STAIRWAY SHALL BE PERMITTED IN EXIT ACCESS STAIRWAY ENCLOSURES. CONTRACTOR TO NOT INSTALL ELECTRICAL BOXES/OUTLETS, SWITCHES, ETC NOT FOR USE FOR THE EXIT ACCESS STAIRWAY AT ALL THE FIRE RATED PARTITIONS.

REFER TO ELECTRICAL DRAWINGS FOR EMERGENCY GENERATOR LOCATION AND REQUIREMENTS.

EMERGENCY LIGHTING SHALL BE DESIGNED IN ALL PATHS OF EGRESS, IN ROOMS WITH AN OCCUPANCY LOAD OF 50 OR MORE.

CODE COMPLIANCE GENERAL NOTES

ONE HOUR FIRE BARRIER WALL ASSEMBLY

TWO HOUR FIRE BARRIER WALL ASSEMBLY

30 MINUTE SMOKE BARRIER WALL ASSEMBLY

SMOKE PARTITION WALL ASSEMBLY

TRAVEL DISTANCE TO EXIT (TD)

EXIT LIGHT SIGN (SEE ELECT)

COORDINATE WALL VERSUS CEILING MOUNTED

RECESSED FIRE EXTINGUISHER & CABINET

RATED DOOR; INDICATES REQUIRED RATING

ACCUMULATION SPACE

HAZARDOUS AREA

EXISTING AREA - NOT IN CONTRACT

LEGEND

FEC

S S

SP SP

EXISTING WALL

2 3 4 5

Tr av el D is ta nc e

' t o

Ex it

LS101

LIFE SAFETY PLAN

1/8" = 1'-0"LS101

1 1st Floor - Life Safety Plan

OCCUPANCY TYPE: INSTITUTIONAL I-2 (IBC)

OCCUPANT LOAD: (240 SQFT/PERSON) 29 PERSONS

MAXIMUM TRAVEL DISTANCE: 200 FT.

MAXIMUM COMMON PATH OF TRAVEL:

MAXIMUM DEAD END: 30 FT

HAZARD CLASSIFICATION: ORDINARY

KEY PLAN - FIRST FLOOR

HEALTHCARE (NFPA 101)

AREA: CLINIC: 6,850 SQFT.

100 FT.

CONSTRUCTION TYPE: 1A (IBC)

1 (332) NFPA 101

CODE REQUIREMENTS

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

Consultant:

5190 Canal Boulevard, Suite 201 New Orleans, LA 70124 (504)835-8013

LACHIN

Architects, apc

Architecture . Planning . Project Management

RENOVATION OF PC BLUE FOR

WOMENS HEALTH

1500 E. Woodrow Wilson Dr. Jackson, MS

586-22-102

2/20/2025 MGL TAC

FINAL SUBMISSION

FULLY SPRINKLERED

Revisions: Date:

1/8" = 1'-0"LS101

2 2ND Floor / Pent House - Life Safety Plan

Pent House: 837 SQFT.

AutoCAD SHX Text 18'-0"

AutoCAD SHX Text 20'-0"

AutoCAD SHX Text 20'-0"

AutoCAD SHX Text 20'-0"

AutoCAD SHX Text 21'-6"

AutoCAD SHX Text 19'-2"

AutoCAD SHX Text 20'-0"

AutoCAD SHX Text 19'-6"

AutoCAD SHX Text 10'-6"

AutoCAD SHX Text 90'-8"

AutoCAD SHX Text 9'-11"

AutoCAD SHX Text 10'-4"

AutoCAD SHX Text 49'-4"

AutoCAD SHX Text 41'-3 1/8"

AutoCAD SHX Text 98'-1 1/2"

AutoCAD SHX Text

EXIST. RF-1

AutoCAD SHX Text

HWP 1

AutoCAD SHX Text

HWP 2

AutoCAD SHX Text

HX-1

AutoCAD SHX Text

HX-2

AutoCAD SHX Text

VFMD 1

AutoCAD SHX Text

VFMD 2

AutoCAD SHX Text

COPY

AutoCAD SHX Text

FILE

AutoCAD SHX Text

FILE

AutoCAD SHX Text

FILE

AutoCAD SHX Text

FILE

AutoCAD SHX Text

ICE

AutoCAD SHX Text

REF.

AutoCAD SHX Text S

AutoCAD SHX Text

MICROWAVE ABOVE

AutoCAD SHX Text

PYXIS

AutoCAD SHX Text U.C.

AutoCAD SHX Text

REF.

AutoCAD SHX Text

MOP

AutoCAD SHX Text

CRASH CART

AutoCAD SHX Text

FILE

AutoCAD SHX Text

COPY

AutoCAD SHX Text

EXISTING TO REMAIN

AutoCAD SHX Text

EXISTING TO REMAIN

AutoCAD SHX Text 16'-4 5/8"

AutoCAD SHX Text

EXISTING TO REMAIN

AutoCAD SHX Text

BLDG. EXPANSION JOINT

AutoCAD SHX Text

BLDG. EXPANSION JOINT

AutoCAD SHX Text

SP

AutoCAD SHX Text 21'-8 3/4"

AutoCAD SHX Text

2010 LA ADDITION

AutoCAD SHX Text S

AutoCAD SHX Text S

AutoCAD SHX Text S

AutoCAD SHX Text S

AutoCAD SHX Text S

AutoCAD SHX Text S

AutoCAD SHX Text S

AutoCAD SHX Text S

AutoCAD SHX Text S

AutoCAD SHX Text S

AutoCAD SHX Text S

AutoCAD SHX Text S

AutoCAD SHX Text S

AutoCAD SHX Text S

AutoCAD SHX Text S

AutoCAD SHX Text S

AutoCAD SHX Text

SP

AutoCAD SHX Text

SP

AutoCAD SHX Text

SP

AutoCAD SHX Text

SP

AutoCAD SHX Text

SP

AutoCAD SHX Text

SP

AutoCAD SHX Text

SP

AutoCAD SHX Text

SP

AutoCAD SHX Text S

AutoCAD SHX Text S

AutoCAD SHX Text S

AutoCAD SHX Text S

AutoCAD SHX Text S

AutoCAD SHX Text S

AutoCAD SHX Text S

AutoCAD SHX Text S

AutoCAD SHX Text S

AutoCAD SHX Text S

AutoCAD SHX Text S

AutoCAD SHX Text

SP

AutoCAD SHX Text

SP

AutoCAD SHX Text

SP

AutoCAD SHX Text

SP

AutoCAD SHX Text

SP

AutoCAD SHX Text

SP

AutoCAD SHX Text

SP

AutoCAD SHX Text

SP

AutoCAD SHX Text

SP

AutoCAD SHX Text

SP

AutoCAD SHX Text

SP

AutoCAD SHX Text

SP

AutoCAD SHX Text

SP

AutoCAD SHX Text

SP

AutoCAD SHX Text

SP

AutoCAD SHX Text

SP

AutoCAD SHX Text

SP

AutoCAD SHX Text

SP

AutoCAD SHX Text

SP

AutoCAD SHX Text

SP

AutoCAD SHX Text

SP

AutoCAD SHX Text

SP

AutoCAD SHX Text

SP

AutoCAD SHX Text

SP

AutoCAD SHX Text

SP

AutoCAD SHX Text

SP

AutoCAD SHX Text

SP

AutoCAD SHX Text

SP

AutoCAD SHX Text

SP

AutoCAD SHX Text

SP

AutoCAD SHX Text

SP

AutoCAD SHX Text

SP

AutoCAD SHX Text

SP

AutoCAD SHX Text

SP

AutoCAD SHX Text

SP

AutoCAD SHX Text

SP

AutoCAD SHX Text

SP

AutoCAD SHX Text

SP

AutoCAD SHX Text

SP

AutoCAD SHX Text

SP

AutoCAD SHX Text

SP

AutoCAD SHX Text

SP

AutoCAD SHX Text

SP

AutoCAD SHX Text

SP

AutoCAD SHX Text

SP

AutoCAD SHX Text

SP

AutoCAD SHX Text

SP

AutoCAD SHX Text

SP

AutoCAD SHX Text

SP

AutoCAD SHX Text

SP

AutoCAD SHX Text

SP

AutoCAD SHX Text

SP

AutoCAD SHX Text

SP

AutoCAD SHX Text

SP

AutoCAD SHX Text

SP

AutoCAD SHX Text

SP

AutoCAD SHX Text

SP

AutoCAD SHX Text

SP

AutoCAD SHX Text

SP

AutoCAD SHX Text

SP

AutoCAD SHX Text

SP

AutoCAD SHX Text

SP

AutoCAD SHX Text

SP

AutoCAD SHX Text

SP

AutoCAD SHX Text

SP

AutoCAD SHX Text

SP

AutoCAD SHX Text

SP

AutoCAD SHX Text

SP

AutoCAD SHX Text

SP

AutoCAD SHX Text

SP

AutoCAD SHX Text

SP

AutoCAD SHX Text

SP

AutoCAD SHX Text

SP

AutoCAD SHX Text

SP

AutoCAD SHX Text

SP

AutoCAD SHX Text

SP

AutoCAD SHX Text

SP

AutoCAD SHX Text

SP

AutoCAD SHX Text

SP

AutoCAD SHX Text

SP

AutoCAD SHX Text

SP

AutoCAD SHX Text

SP

AutoCAD SHX Text

SP

AutoCAD SHX Text

SP

AutoCAD SHX Text

SP

AutoCAD SHX Text

SP

AutoCAD SHX Text

SP

AutoCAD SHX Text

SP

AutoCAD SHX Text

SP

AutoCAD SHX Text

SP

AutoCAD SHX Text

SP

AutoCAD SHX Text

SP

AutoCAD SHX Text

SP

AutoCAD SHX Text

SP

AutoCAD SHX Text

SP

AutoCAD SHX Text

SP

AutoCAD SHX Text

SP

AutoCAD SHX Text

SP

AutoCAD SHX Text

EXISTING FLOOR/CLG. PENETRATION

AutoCAD SHX Text

EXISTING FLOOR/CLG. PENETRATION

AutoCAD SHX Text 20'-0"

AutoCAD SHX Text 20'-0"

AutoCAD SHX Text 20'-0"

AutoCAD SHX Text 10'-2 1/2"

AutoCAD SHX Text

PUMP 1

AutoCAD SHX Text

PUMP 2

AutoCAD SHX Text

AHU 1

AutoCAD SHX Text

VFD 2

AutoCAD SHX Text

VFD 1

AutoCAD SHX Text

NEW INSULATED METAL COILING DOOR

AutoCAD SHX Text

NEW 2" INSULATED METAL PANELS OVER 8" GIRTS

AutoCAD SHX Text

EXISTING STAIR

EXIT

AREA OF WORK

128' 129'

126'

LS102

LIFE SAFETY PLAN - OVERALL

FIRST LEVEL

1" = 360'-0"LS102

1 Life Safety Plan - Overall First Level

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

Consultant:

5190 Canal Boulevard, Suite 201 New Orleans, LA 70124 (504)835-8013

LACHIN

Architects, apc

Architecture . Planning . Project Management

RENOVATION OF PC BLUE FOR

WOMENS HEALTH

1500 E. Woodrow Wilson Dr. Jackson, MS

586-22-102

2/20/2025 MGL TAC

FINAL SUBMISSION

FULLY SPRINKLERED

Revisions: Date:

B

C

D

E

F

Ex A

Ex A

Ex A

Ex A Ex A

Ex B

Ex B

Ex B

Ex A

Ex A

Ex CEx C

Ex F

Ex D

Ex E

Ex A

E

E

BC-1212

BC-1213

BC-1219

STAIR 11

MECH.

STAIR

STAIR 8

CHASE

BC-1208

BC-1207

BC-1206

BC-1205

BC-1203

BC-1204

BC-1209

C O

R R

ID

O

R C

-2

BC-1216

T-1 T-2

T-3

T-4

EXIT

EXIT

EXIT

BC-1202

BC-1237

BC-1236 BC-1235 BC-1234 BC-1233 BC-1232

CORRIDOR C-8

CORRIDOR C-5

BC-1226

WAITING

BC-1220 BC-1222

T-5

T-6

T-7

BC-1230

BC-1214

BC-1215 BC-1221 BC-1223 BC-1225 BC-1227

BC-1224

C-6

C-7

A

1 2 3 4 5

B

C

D

E

F

BC-1212 BC-1213

BC-1219

STAIR 11

MECH.

STAIR

STAIR 8

CHASE

BC-1208

BC-1207

BC-1206

BC-1205

BC-1203 BC-1204

BC-1209

C O

R R

ID

O

R C

-2 BC-1216

T-1 T-2

T-3

T-4

EXIT

EXIT

EXIT

BC-1202

BC-1237

BC-1236 BC-1235 BC-1234 BC-1233 BC-1232

CORRIDOR C-8

CORRIDOR C-5

BC-1226

WAITING

BC-1220

BC-1222

T-5

T-6

T-7

BC-1230

BC-1214

BC-1215

BC-1221 BC-1223 BC-1225 BC-1227

BC-1224

C-6

C-7

WALL TYPE (SHEET AD102)

LEGEND

EXISTING PARTITION TO REMAIN

Ex A

DEMOLISH PARTITION

DEMOLISH PLUMBING FIXTURE

DEMOLISH DOOR AND FRAME

DEMOLISH LIGHT FIXTURE

DEMOLISH MECH. DIFFUSER

NEW WALL TYPE (SHEET A602)E

1/8" = 1'-0"AD100

1 1st Floor Demolition Plan

1/8" = 1'-0"AD100

2 1st Floor Demolition RCP

AD100

ARCHITECTURAL DEMO FLOOR

PLAN & RCP

KEY PLAN - FIRST FLOOR

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

Consultant:

5190 Canal Boulevard, Suite 201 New Orleans, LA 70124 (504)835-8013

LACHIN

Architects, apc

Architecture . Planning . Project Management

RENOVATION OF PC BLUE FOR

WOMENS HEALTH

1500 E. Woodrow Wilson Dr. Jackson, MS

586-22-102

2/20/2025 MGL TAC

FINAL SUBMISSION

FULLY SPRINKLERED

Revisions: Date:

DEMOLITION KEY NOTES

EXISTING CEILING SYSTEMS TO REMAIN - PROTECT FROM DAMAGE.

TEMPORARILY REMOVE EXISTING CEILING SYSTEM TO INSTALL NEW ABOVE

CEILING WORK. RESTORE OR REPLACE EXISTING CEILING SYSTEM TO MATCH

AFTER INSTALLATION.

REMOVE ALL EXISTING PLUMBING FIXTURES

EXISTING FINISHES ARE TO REMAIN IN THIS AREA - PROTECT FROM DAMAGE

REMOVE ALL DRYWALL AND FURRING AT EXTERIOR WALL AND AROUND ALL

COLUMNS, TYPICAL

1. ALL EXISTING PLUMBING IDENTIFIED TO BE DEMOLISHED SHALL BE REMOVED WITH LINES CAPPED. REFER TO PLUMBING SHEETS

FOR ADDITIONAL SCOPE. MAINTAIN SECURITIES TO FLOORS ABOVE AND BELOW.

2. DEMOLISH EXISTING FLOORING THROUGHOUT THE LIMITS OF WORK.

3. DEMOLISH EXTERIOR WALL FINISHES. EXTERIOR WALL CONSTRUCTION IS TO REMAIN UNLESS NOTED OTHERWISE.

4. ITEMS SHOWN DASHED ARE TO BE DEMOLISHED, INCLUDING ALL CABINET WORK.

5. DEMOLISH EXISTING PARTITIONS HANDRAILS, CRASH RAILS, CORNER GUARDS, AND SHEET WALL PROTECTION PANELS

THROUGHOUT THE LIMITS OF WORK.

6. DEMOLISH EXISTING CEILING AND ALL CEILING DEVICES THROUGHOUT THE LIMITS OF WORK. SEE ELECTRICAL SHEETS FOR

ADDITIONAL SCOPE AND ITEMS TO BE RELOCATED.

7. REMOVE AND DELIVER TO COR ALL EQUIPMENT, FIXTURES, OR ACCESSORIES IDENTIFIED BY THE COR TO BE SALVAGED. DELIVER

SALVAGEABLE ITEMS TO THE COR AS DIRECTED.

8. REMOVE ALL EXISTING PLUMBING FIXTURES THROUGHOUT THE LIMITS OF WORK. CONTRACTOR TO COORDINATE REMOVAL OF PLUMBING FIXTURES AND CAPPING PIPING TO MINIMIZE DISRUPTION TO PLUMBING ABOVE AND BELOW. RE-ROUTING OF PLUMBING LINES THAT SERVE THE FIRST AND THIRD FLOORS SHALL BE PHASED AND COORDINATED WITH THE COR TO MINIMIZE

DISRUPTIONS TO SYSTEMS ABOVE AND BELOW THE SCHEDULED WORK.

9. COORDINATE SLAB DEMOLITION AND RESTORATION WITH NEW PLUMBING WORK.

10. COORDINATE DEMOLITION MATERIALS REMOVAL PROCEDURES WITH THE COR.

11. AT ALL WALLS TO REMAIN, CONTRACTOR TO REMOVE ALL WALL MOUNTED ITEMS, INCLUDING BUT NOT LIMITED TO: SWITCHES, OUTLETS, FIXTURES & EQUIPMENT. REFER TO MECHANICAL & ELECTRICAL SHEETS FOR ADDITIONAL SCOPE.

GENERAL DEMOLITION NOTES

1 2

3 33

1. REMOVE ALL EXISTING CEILING SYSTEMS INCLUDING ALL CEILING MOUNTED DEVICES AND SYSTEMS WITHIN THE PROJECT AREA.

COORDINATE WITH THE COR AND ITEMS TO BE SALVAGED OR RE-USED. NOT ALL CEILING MOUNTED DEVICES ARE SHOWN ON THIS DRAWING. CONTRACTORS ARE TO VISIT THE SITE AND TAKE NOTE OF THE SCOPE OF ALL EXISTING DEVICES TO BE REMOVED.

2. COORDINATE ANY REMOVAL OF ANY SYSTEM(S) THAT MIGHT DISRUPT OR INTERRUPT THE ONGOING OPERATIONS OF ANY AREA

OUTSIDE OF THE PROJECT AREA.

3. REMOVE ALL LIGHT FIXTURES. COORDINATE WITH THE COR AND ITEMS TO BE SALVAGED OR RE-USED.

GENERAL REFLECTED CEILING DEMOLITION NOTES

AutoCAD SHX Text 18'-0"

AutoCAD SHX Text 20'-0"

AutoCAD SHX Text 20'-0"

AutoCAD SHX Text 20'-0"

AutoCAD SHX Text 21'-6"

AutoCAD SHX Text 19'-2"

AutoCAD SHX Text 20'-0"

AutoCAD SHX Text 19'-6"

AutoCAD SHX Text 10'-6"

AutoCAD SHX Text 90'-8"

AutoCAD SHX Text 9'-9 1/2"

AutoCAD SHX Text 10'-2 1/2"

AutoCAD SHX Text 49'-0"

AutoCAD SHX Text 41'-1 5/8"

AutoCAD SHX Text 98'-0"

AutoCAD SHX Text

2010 LA ADDITION

AutoCAD SHX Text

EXISTING SERVER TO RELOCATE TO NEW LOCATION. SEE PROPOSED PLAN

AutoCAD SHX Text 10'-2 3/4"

AutoCAD SHX Text

EXISTING TO REMAIN

AutoCAD SHX Text

EXISTING TO REMAIN

AutoCAD SHX Text DEMOLISH EXISTING AIR-HANDLING UNIT, SEE MECHANICAL DRAWINGS FOR ADDITIONAL SCOPE

AutoCAD SHX Text

DEMO CURB

AutoCAD SHX Text

DEMOLISH CHILLED WATER BOOSTER PUMP

AutoCAD SHX Text

CHILLED WATER PIPING FLOOR PENETRATIONS

AutoCAD SHX Text

EXISTING FLOOR OPENING TO REMAIN

AutoCAD SHX Text

EXISTING FAN UNIT AND DUCT TO REMAIN.

AutoCAD SHX Text

DEMOLISH EXISTING THROUGH WALL DUCT WORK

AutoCAD SHX Text

MAINTAIN A WEATHER TIGHT SEAL DURING CONSTRUCTION.

AutoCAD SHX Text

AutoCAD SHX Text

DEMOLISH PUMP

AutoCAD SHX Text

EXISTING FLOOR OPENING TO REMAIN

AutoCAD SHX Text

BUILDING EXPANSION JOINT

AutoCAD SHX Text

INSTALL TEMPORARY 1 HOUR FIRE RATED CONSTRUCTION DOORS PRIOR TO DEMOLITION

AutoCAD SHX Text LINE OF TEMPORARY ONE HOUR FIRE RATED PARTITION. INSTALL PRIOR TO DEMOLITION AND NEW WORK

AutoCAD SHX Text

COORDINATE ACCEPTABLE CORRIDOR CLEARANCE WITH COR

AutoCAD SHX Text 6'-8 3/8"

AutoCAD SHX Text 6"

AutoCAD SHX Text 3'-0"

AutoCAD SHX Text 3'-0"

AutoCAD SHX Text 18'-0"

AutoCAD SHX Text 20'-0"

AutoCAD SHX Text 20'-0"

AutoCAD SHX Text 20'-0"

AutoCAD SHX Text 21'-6"

AutoCAD SHX Text 19'-2"

AutoCAD SHX Text 20'-0"

AutoCAD SHX Text 19'-6"

AutoCAD SHX Text 10'-6"

AutoCAD SHX Text 90'-8"

AutoCAD SHX Text 9'-9 1/2"

AutoCAD SHX Text 10'-2 1/2"

AutoCAD SHX Text 49'-0"

AutoCAD SHX Text 41'-1 5/8"

98'-0"

B

C

D

E

P

E

E

A

1 2 3 4 5

B

C

D

E

P

AREAS OF POTENTIAL CEILING

DEMOLITION DUE TO PLUMBING

REQUIREMENTS AT FLOOR ABOVE.

Room M-39

Room M-22

Room M-21

Room M-19

Room M-42

Room M-36

Room M-35

Room M-17

Room M-12

Room M-13

GYPSUM BOARD CEILING

GYPSUM BOARD CEILING

GYPSUM BOARD CEILING

AD101

ARCHITECTURAL DEMO PLANS

AND RCP

1/8" = 1'-0"AD101

1 2nd Level Demolition Plan

1/8" = 1'-0"AD101

2 Basement Level Demolition RCP - Radiological Oncology

KEY PLAN - FIRST FLOOR

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

Consultant:

5190 Canal Boulevard, Suite 201 New Orleans, LA 70124 (504)835-8013

LACHIN

Architects, apc

Architecture . Planning . Project Management

RENOVATION OF PC BLUE FOR

WOMENS HEALTH

1500 E. Woodrow Wilson Dr. Jackson, MS

586-22-102

2/20/2025 MGL TAC

FINAL SUBMISSION

FULLY SPRINKLERED

Revisions: Date:

NOTE

SOME AREAS OF THE FIRST FLOOR SUCH AS ONCOLOGY AND OTHER AREAS ARE

PARTICULARLY SENSITIVE TO DISRUPTION. THEY WILL REQUIRE CLOSE COORDINATION WITH

THE COR TO IDENTIFY THE AVAILABLE TIMES AND LENGTH OF DISRUPTION THAT WILL BE

ACCEPTABLE TO MINIMIZE DOWN-TIME IN THESE AREAS. SOME AFTER-HOURS WORK SHOULD

BE ANTICIPATED AND CAREFULLY SCHEDULED WITH THE COR. TEMPORARY RE-ROUTING OF

PLUMBING MAY BE REQUIRED TO MINIMIZE DISRUPTION OF SERVICES TO THE THIRD FLOOR

ABOVE THE WORK AREA UNTIL THE PERMANENT PLUMBING SYSTEM IS IN PLACE.

THIS FLOOR PLAN ILLUSTRATES THE GENERAL LAYOUT OF AREAS ON THE FIRST FLOOR BELOW

THE SECOND FLOOR WARD 2A AREA WHERE THE BULK OF DEMOLITION AND CONSTRUCTION

WILL BE OCCURRING. AS THIS DRAWING WAS CREATED FROM THE BEST AVAILABLE DRAWINGS

OF THIS AREA AT THAT TIME, SOME DIFFERENCES TO THE LAYOUT SHOULD BE EXPECTED AS

THERE HAS BEEN SOME MINOR RENOVATION WORK THAT HAS OCCURRED SINCE THE DRAWING

WAS CREATED.

GENERAL NOTES

1.

2.

3.

THIS SHEET IS INCLUDED AS A COURTESY AND SHOWS APPROXIMATE LOCATIONS OF

EXISTING SPACES AND PARTITIONS ON THE FLOOR BELOW THE AREA OF WORK TO ASSIST

THE CONTRACTOR IN COORDINATING AND SCHEDULING THE ABOVE CEILING WORK WITH

THE COR. ACCURACY OF THIS PLAN IS NOT GUARANTEED AS IT WAS DRAWN FROM THE

BEST AVAILABLE AS-BUILT DRAWINGS PROVIDED BY THE OWNER. CONTRACTOR TO VISIT

THE SITE TO CONFIRM EXISTING CONDITIONS.

WITH THE EXCEPTION OF ABOVE CEILING WORK AND REPAIR OR REPLACEMENT OF CEILING

AND RELATED SYSTEMS, NO NEW WORK IS TO OCCUR ON THIS FLOOR EXCEPT AS

NECESSARY TO INSTALL THE WORK AT THE SECOND FLOOR.

ANY DAMAGES OR DISRUPTIONS TO THE EXISTING CONSTRUCTION ON THIS FLOOR AS A

RESULT OF INSTALLING WORK FOR THE SECOND FLOOR SHALL BE REPAIRED AND

COORDINATED WITH THE COR.

CEILING AREAS TO BE DISRUPTED TO

INSTALL / MODIFY ABOVE CEILING

CONSTRUCTION

LEGEND

GYPSUM BOARD CEILING

4. CEILING TYPE IS 2X2 ACOUSTICAL CEILING TILE UNLESS OTHERWISE NOTED.

AutoCAD SHX Text 13'-4"

AutoCAD SHX Text 8'-4"

AutoCAD SHX Text DEMOLISH EXISTING ROOFING SYSTEM AND PERIMETER FLASHING. PROVIDE TEMPORARY PROTECTION DURING DEMOLITION.

AutoCAD SHX Text

NO WORK

AutoCAD SHX Text

TEMPORARY PARTITION

AutoCAD SHX Text

DEMOLISH EXTERIOR WALL TO ACCOMMODATE NEW OPENING

AutoCAD SHX Text 8"

AutoCAD SHX Text 8"

AutoCAD SHX Text REMOVE AND SALVAGE BRICK VENEER FROM SECOND FLOOR TO TOP OF ROOF DECK. TERMINATE DEMOLITION 8" FROM EDGE OF ROOF WITH SAW CUT. DEMOLISH AND DISCARD BRICK TIES. PREP STUD WALLS AND SHEATHING FOR NEW WORK.

AutoCAD SHX Text 19'-1 5/8"

AutoCAD SHX Text 40'-3 5/8"

DEMOLISH ROOF DRAIN

Existing Demo Partition Type - Ex A

SILL

PLAN

SILL

PLAN

Existing Demo Partition Type - Ex B Existing Demo Partition Type - Ex C

SILL

PLAN

Existing Demo Partition Type - Ex D Existing Demo Partition Type - Ex E

SILL

PLAN

SILL

PLAN

Existing Demo Partition Type - Ex F

SILL

PLAN

EXISTING CMU WALL/STRUCTURE

AD102

WALL TYPES - SELECTIVE

DEMOLITION

3/4" = 1'-0"1 EXISTING PARTITION TYPES - DEMOLITION

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

Consultant:

5190 Canal Boulevard, Suite 201 New Orleans, LA 70124 (504)835-8013

LACHIN

Architects, apc

Architecture . Planning . Project Management

RENOVATION OF PC BLUE FOR

WOMENS HEALTH

1500 E. Woodrow Wilson Dr. Jackson, MS

586-22-102

2/20/2025 MGL TAC

FINAL SUBMISSION

FULLY SPRINKLERED

Revisions: Date:

AutoCAD SHX Text

VARIES

AutoCAD SHX Text

EXISTING CMU WALL/STRUCTURE TO REMAIN

AutoCAD SHX Text

DEMOLISH EXISTING LAY-IN CEILING

AutoCAD SHX Text

DEMOLISH " GYP. BD. 58" GYP. BD. AND " MTL. HAT 78" MTL. HAT CHANNELS

AutoCAD SHX Text

DEMOLISH EXISTING BASEBOARD

AutoCAD SHX Text

EXISTING CONCRETE DECK/CEILING

AutoCAD SHX Text

EXISTING CMU WALL/STRUCTURE

AutoCAD SHX Text

EXISTING CONCRETE DECK/CEILING

AutoCAD SHX Text

VARIES

AutoCAD SHX Text

EXISTING CONCRETE DECK/CEILING

AutoCAD SHX Text

DEMOLISH " GYP. BD. 58" GYP. BD. AND 4" MTL. STUDS.

AutoCAD SHX Text

DEMOLISH EXISTING LAY-IN CEILING

AutoCAD SHX Text

EXISTING CMU WALL/STRUCTURE TO REMAIN

AutoCAD SHX Text

DEMOLISH EXISTING BASEBOARD

AutoCAD SHX Text

VARIES

AutoCAD SHX Text

EXISTING 4" METAL STUD TO REMAIN

AutoCAD SHX Text

VARIES

AutoCAD SHX Text 9"

AutoCAD SHX Text

EXISTING CMU WALL/STRUCTURE TO REMAIN

AutoCAD SHX Text

GYPSUM WALL BOARD TO REMAIN, PREP TO RECEIVE NEW PAINT

AutoCAD SHX Text

DEMOLISH EXISTING BASEBOARD

AutoCAD SHX Text

DEMOLISH EXISTING LAY-IN CEILING

AutoCAD SHX Text

DEMOLISH EXISTING LAY-IN CEILING

AutoCAD SHX Text

EXISTING 4" METAL STUD TO REMAIN

AutoCAD SHX Text

GYPSUM WALL BOARD TO REMAIN, PREP TO RECEIVE NEW PAINT

AutoCAD SHX Text

DEMOLISH EXISTING BASEBOARD

AutoCAD SHX Text

EXISTING CONCRETE DECK/CEILING

AutoCAD SHX Text

EXISTING 4" METAL STUD TO REMAIN

AutoCAD SHX Text

GYPSUM WALL BOARD TO REMAIN, PREP TO RECEIVE NEW PAINT

AutoCAD SHX Text

DEMOLISH EXISTING BASEBOARD

AutoCAD SHX Text EXISTING PARTITION TO REMAIN A 2 HOUR RATED ASSEMBLY DURING CONSTRUCTION AND UPON PROJECT COMPLETION.

AutoCAD SHX Text

AutoCAD SHX Text

EXISTING CONCRETE DECK/CEILING

AutoCAD SHX Text

EXISTING CONCRETE DECK/CEILING

AutoCAD SHX Text

VARIES

AutoCAD SHX Text EXISTING PARTITION TO REMAIN A 2 HOUR RATED ASSEMBLY DURING CONSTRUCTION AND UPON PROJECT COMPLETION.

AutoCAD SHX Text

AutoCAD SHX Text EXISTING PARTITION TO REMAIN A 2 HOUR RATED ASSEMBLY DURING CONSTRUCTION AND UPON PROJECT COMPLETION.

BC-1212 BC-1213

BC-1219

STAIR 11

MECH.

STAIR

STAIR 8

CHASE

BC-1208

BC-1207

BC-1206

BC-1205

BC-1203

BC-1204

BC-1209

C O

R R

ID

O

R C

-2

BC-1216

T-1 T-2

T-3

T-4

EXIT

EXIT

EXIT BC-1202

BC-1237

BC-1236 BC-1235 BC-1234 BC-1233 BC-1232

CORRIDOR C-8

CORRIDOR C-5

BC-1226

WAITING

BC-1220 BC-1222

T-5

T-6

T-7

BC-1230

BC-1214

BC-1215 BC-1221 BC-1223 BC-1225 BC-1227

BC-1224

C-6

C-7

A

1 2 3 4 5

B

C

D

E

F

A

1 2 3 4 5

B

C

D

E

F

NO WORK

1/8" = 1'-0"A100 1 First Floor Phasing Plan

A100

ARCHITECTURAL PHASING PLAN

KEY PLAN - FIRST FLOOR

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

Consultant:

5190 Canal Boulevard, Suite 201 New Orleans, LA 70124 (504)835-8013

LACHIN

Architects, apc

Architecture . Planning . Project Management

RENOVATION OF PC BLUE FOR

WOMENS HEALTH

1500 E. Woodrow Wilson Dr. Jackson, MS

586-22-102

2/20/2025 MGL TAC

FINAL SUBMISSION

FULLY SPRINKLERED

Revisions: Date:

GENERAL PHASING NOTES

CONTRACTOR TO COORDINATE WITH COR AND SUBMIT A DETAILED

PHASING PLAN FOR THE WORK BEFORE CONSTRUCTION BEGINS.

PHASING PLAN SHALL BE APPROVED BY THE COR.

THE DETAILED PHASING PLAN SHOULD INCLUDE PHASED DISRUPTION

DURATIONS OF SPACES ABOVE THE SECOND FLOOR AND SPACES

BELOW THE SECOND FLOOR THAT WILL BE NECESSARY TO INSTALL

THIS NEW WORK.

1/8" = 1'-0"A100 2 Second Floor - Pent House Phasing Plan

KEY PLAN - Second Floor - Mech. PentHouse

AutoCAD SHX Text

BUILDING EXPANSION JOINT

AutoCAD SHX Text 6'-8 3/8"

AutoCAD SHX Text 6"

AutoCAD SHX Text 3'-0"

AutoCAD SHX Text 3'-0"

AutoCAD SHX Text

TEMPORARY PARTITION, DOOR & FRAME

AutoCAD SHX Text

COORDINATE ACCEPTABLE CORRIDOR CLEARANCE WITH COR

AutoCAD SHX Text 18'-0"

AutoCAD SHX Text 20'-0"

AutoCAD SHX Text 20'-0"

AutoCAD SHX Text 20'-0"

AutoCAD SHX Text 21'-6"

AutoCAD SHX Text 19'-2"

AutoCAD SHX Text 20'-0"

AutoCAD SHX Text 19'-6"

AutoCAD SHX Text 10'-6"

AutoCAD SHX Text 90'-8"

AutoCAD SHX Text 9'-9 1/2"

AutoCAD SHX Text 10'-2 1/2"

AutoCAD SHX Text 49'-0"

AutoCAD SHX Text 41'-1 5/8"

AutoCAD SHX Text 98'-0"

AutoCAD SHX Text

RF-1

AutoCAD SHX Text

AHU-1

AutoCAD SHX Text 18'-0"

AutoCAD SHX Text 20'-0"

AutoCAD SHX Text 20'-0"

AutoCAD SHX Text 20'-0"

AutoCAD SHX Text 21'-6"

AutoCAD SHX Text 19'-2"

AutoCAD SHX Text 20'-0"

AutoCAD SHX Text 19'-6"

AutoCAD SHX Text 10'-6"

AutoCAD SHX Text 90'-8"

AutoCAD SHX Text 9'-9 1/2"

AutoCAD SHX Text 10'-2 1/2"

AutoCAD SHX Text

EXISTING FLOOR PENETRATION

AutoCAD SHX Text

PUMP 1

AutoCAD SHX Text

PUMP 2

AutoCAD SHX Text

EXISTING FLOOR PENETRATION

AutoCAD SHX Text

AHU 1

AutoCAD SHX Text

VFD 2

AutoCAD SHX Text

VFD 1

AutoCAD SHX Text

NEW INSULATED METAL COILING DOOR

AutoCAD SHX Text

NEW 2" INSULATED METAL PANELS OVER 8" GIRTS

1HR. TEMPORARY PARTITION AND DOORS

B

C

D

E

F

FEC

FEC

FEC

FE

FEC

ELEVATOR LOBBY STAIRWELL

MEP CHASE

2010 LA Addition

STAIR 1

MPE 1

115 B

MPE 5

109 B

MPE 6

108 B

RECEPTION

116 A

WAITING

100 D

GPR

118 B

SUR

124 A

CUR

125 A

CHIEF

126 A

MECHANICAL

123 E

LACTATION

101 A

SWO

139 A

MEDICATION

128 A

DIETICIAN

129 A

PHARM

130 A

HAC

135 A

STORAGE 5

131 A

NURSE

121 A

TOILET

119 C ST

OR

AG

E

A

EHRM

140 E

PACT TEAM AREA

105 A

CORRIDOR A

102 A

STORAGE 1

107 A

MPE 4

110 B

MPE 3

111 B

MPE 2

114 B P. TOILET 1

113 C

P. TOILET 2

112 C

STORAGE 2

103 A

STAFF TOILET

136 C

NURSE

137 A

BREAK ROOM

132 C

SUPPLY

GYNO

133 A

HALL 2

104 A

HALL 1

106 A

MHO

138 A

CORRIDOR B

120 A STORAGE 4

127 A

6 MTL LOCKERS

102A

116A 116B

118B

8A

102B

114A115A

115B 114B

111B

0B

0A

1A

9A

9B

108B 10 8A

A104

A104

A104

A201

0A

A104

A104

FLOOR AND CEILING

EXPANSION JOINT COVER

C3 C3

C3

C3

D3

C3

C3

C3

C3

C3D3

C3

C3

C3

C3

C3

C3

C3

C3

C3

C3

C3

C3

C3

C3

E3

C3C3

C3 C3

C3 C3

C3

F3

F3

D3

C3

E3 C3

C3

C3

C3

C3

A0

TYP AT ALL

COLUMNS

CO

RR

ID

OR

A

A

A0 F3

D3 C3

A0

C3

B

C3

C3

D3

C3

A0

A0

E3

A1

A0

C3

C3 A0

A0

C3

A0

E3

C3

C3 E3

B

C3

A0

A0

D3

D3

B

C3

C3 A0

D3D3

C3 A

2C

A2A0

A2

A2

A2

A2

A2

A2

E3

A2

A2

A2

A0

E3

A2 A3 A0

A0

A0

A2

A2

A0

E3

A0

A A

C3

E3

E3

C3

C3

A0A0

E3

E3

E6

A104

A106

25 14

5 6

MECHANICAL

PENTHOUSE

200 E

NEW HM DOOR AND FRAME

NEW 96"x96" OVERHEAD

COILING DOOR

A201

PREFINISHED INSULATED

METAL WALL PANEL

CONCRETE CURB

REF TO STRUCTURAL

STEEL COLUMN

REF TO STRUCTURAL

STEEL WALL GIRT

REF TO STRUCTURAL

NEW MECH EQUIPMENT

REF TO MECH

1'-0

8'-0

16' -6

1/2

200B

200A

A201

A201

A201

A

1 2 3 4 5

B

C

D

E

F

CO

RR

ID

OR

PCC 2133

PCC

2133A

PCC

PCC 2131 PC

C

PCC 2130

PCC 2104

HAC

PCC 2108 PCC 2129

PCC 2107

PCC 2128

PCC 2109

PCC 2110

PCC 2112

STAIR

ELECTRICALIT CLOSET

PCC 2113 PCC 2114 PCC 2115 PCC 2117 PCC 2119

PCC 2120

PCC 2121

PCC 2122

PCC 2123

PCC 2124

PCC 2118

PCC 2125

PCC 2116

PCC 2126

PCC 2111

STORAGE

CORRIDOR

GUARD RAIL SEE DETAILS 3:A201

& 14:A202

CORNER GUARD

WALL TYPE (SHEET A601)

RECESSED FIRE EXTINGUISHER & CABINET

LEGEND

FEC

EXISTING PARTITION TO REMAIN

CG

A2

NEW PARTITION

B WINDOW OPENING (SHEET A601)

INTERIOR ELEVATION (SHEETS A104 thru 106)

WALL PROTECTIONWP

WALL MOUNTED FIRE EXTINGUISHERFE

A101

FLOOR PLAN - 1ST & 2ND

1/8" = 1'-0"A101 1 1st Floor Plan - New PACT Clinic

1/8" = 1'-0"A101 2 2nd Floor Plan - New HVAC Penthouse

KEY PLAN - FIRST FLOOR

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

Consultant:

5190 Canal Boulevard, Suite 201 New Orleans, LA 70124 (504)835-8013

LACHIN

Architects, apc

Architecture . Planning . Project Management

RENOVATION OF PC BLUE FOR

WOMENS HEALTH

1500 E. Woodrow Wilson Dr. Jackson, MS

586-22-102

2/20/2025 MGL TAC

FINAL SUBMISSION

FULLY SPRINKLERED

Revisions: Date:

HWP HORIZONTAL HEATING WATER PUMPS

ABBREVIATIONS

VFMD VARIABLE FREQUENCY MOTOR DRIVES

AHU AIR HANDLING UNIT

HX HOT WATER HEAT EXCHANGE

CC CRASH CART

GENERAL NOTES

CONTRACTOR SHALL VERIFY EXISTING CONDITIONS.

DIMENSIONS ARE TO FINISH UNLESS OTHERWISE NOTED.

ANY DIMENSIONAL DISCREPANCIES BETWEEN DRAWING

DIMENSIONS AND EXISTING FIELD CONDITIONS SHALL BE

BROUGHT TO THE ATTENTION OF THE COR IMMEDIATELY.

SIGNAGE LOCATIONS ARE IDENTIFIED ON SHEET A103.

SYSTEMS FURNITURE AND DESK DIVIDERS SHOWN IN “PACT TEAM

AREA 105” ARE VA PROVIDED AND CONTRACTOR INSTALLED. SEE

ELECTRICAL FOR POWER CONNECTION LOCATIONS.

COORDINATE FURNITURE ARRANGEMENT WITH COR PRIOR TO

INSTALLATION.

SEE SHEET A602 FOR PARTITION TYPES.

FLOOR & CEILING PENETRATIONS THAT ARE ABANDONED SHALL BE

REPAIRED TO MAINTAIN 2 HOUR SEPARATION REQUIREMENTS.

DUCT & PIPE PENETRATIONS THROUGH FLOOR & CEILING SHALL BE

CAULKED WITH FIRE RATED SEALANT TO MAINTAIN 2 HOUR

SEPARATION.

1.

2.

3.

4.

6.

7.

5.

8.

9.

AutoCAD SHX Text 18'-0"

AutoCAD SHX Text 20'-0"

AutoCAD SHX Text 20'-0"

AutoCAD SHX Text 20'-0"

AutoCAD SHX Text 21'-6"

AutoCAD SHX Text 19'-2"

AutoCAD SHX Text 20'-0"

AutoCAD SHX Text 19'-6"

AutoCAD SHX Text 10'-6"

AutoCAD SHX Text 90'-8"

AutoCAD SHX Text 9'-11"

AutoCAD SHX Text 10'-4"

AutoCAD SHX Text 49'-4"

AutoCAD SHX Text 41'-3 1/8"

AutoCAD SHX Text 98'-1 1/2"

AutoCAD SHX Text

EXIST. RF-1

AutoCAD SHX Text

HWP 1

AutoCAD SHX Text

HWP 2

AutoCAD SHX Text

HX-1

AutoCAD SHX Text

HX-2

AutoCAD SHX Text

VFMD 1

AutoCAD SHX Text

VFMD 2

AutoCAD SHX Text

COPY

AutoCAD SHX Text

FILE

AutoCAD SHX Text

FILE

AutoCAD SHX Text

FILE

AutoCAD SHX Text

FILE

AutoCAD SHX Text

ICE

AutoCAD SHX Text

REF.

AutoCAD SHX Text S

AutoCAD SHX Text

MICROWAVE ABOVE

AutoCAD SHX Text

PYXIS

AutoCAD SHX Text U.C.

AutoCAD…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .