5203ZN01 Attachment (2) 2370.2-7445 CDM OUTSERT SHIELDING.pdf
PDF 206 KB Posted
- Attached to
- Tungsten Impregnated Shielding Federal contract opportunity
- Solicitation number
- N4215825QE093
About this file
This document is a technical drawing and specification for a CDM Outsert Shielding component for Norfolk Naval Shipyard's Code 2370 Reactor Servicing department. The drawing details a magnetic tungsten impregnated rubber shield designed to fit around a standard 8" Schedule 40 pipe, with specific requirements including:
Key specifications include a minimum density of 7 g/cc, total value length (TVL) greater than or equal to 2.00", and a weight limit under 40 lbs per piece. The design calls for 6 pieces that must fit together without gaps, with a magnetic layer positioned on the interior surface. Fabrication notes mandate labeling each piece with "RF-7445" and its weight in a non-yellow/non-magenta color. The drawing was created by Alyx Davidson and checked by Samuel Bower on 08JUL2025, with an original issue date of 07/07/25, and is classified as unclassified.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| 5203ZN01 Attachment (3) Certified Test Reports.docx | DOCX document | |
| 5203ZN01 Continuation Sheet.docx | DOCX document | |
| 5203ZN01 Silfelx patent.pdf | ||
| 5203ZN01 Attachment (1) Fabrication Details.docx | DOCX document |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
ISO VIEW
TOP VIEW
FRONT VIEW
VIEW A-A
(ENLARGED)
A A
A
B
C
D
E
F
8 7 6 5 4 3 2 1
8 7 6 5 4 3 2 1
F
E
D
C
B
A
UNLESS OTHERWISE
SPECIFIED, ALL
DIMENSIONS ARE IN
INCHES, AND TOLERANCES
ARE AS FOLLOWS:
DECIMALS
X = +/- 0.250
X.X = +/- 0.062
X.XX = +/- 0.010
X.XXX = +/- 0.005
FRACTIONS = +/- 1/8
ANGLES = +/- 1 DEG.
NORFOLK NAVAL SHIPYARD
CODE 2370 REACTOR SERVICING
TITLE
SIZE SCALE DWG NO. REV
CLASSIFICATION
DRAWN
CHECKED
CONCURRENCE
CONCURRENCE
CONCURRENCE
APPROVED
CDM OUTSERT SHIELDING
2370.2-7445A OI
SHEET 1 OF 1 UNCLASSIFIED
NTS
DATE
DATE
DATE
DATE
DATE
DATE
ALYX DAVIDSON 08JUL2025
SAMUEL BOWER (SOF) 08JUL2025
PARTS LIST
PC. #
QTY.
DESCRIPTION SPECIFICATION
1 1 Outsert Shield
-Magnetic Tungeston impregnated rubber shielding with a minimum density of 7 g/cc and TVL greater than or equal to 2.00", APL
FABRICATION NOTES
# NOTE
1 CALCULATED WEIGHT FOR EACH PIECE IS <40 LBS.
QTY 6 MUST FIT TOGETHER AROUND A STANDARD 8" SCHEDULE 40 PIPE
WITH NO GAPS PRESENT.
LABEL "RF-7445" ALONG WITH THE WEIGHT ON THE EXTERIOR OF THE
PIECE. CHARACTER AND SIZE TO SUIT. (THIS SHOULD BE DONE BY THE
VENDOR IN A SUITABLE COLOR OTHER THAN YELLOW OR MAGENTA).
QTY 6 PC 1'S ARE REQUIRED PER POSITION.
MAGNETIC LAYER TO BE ON THE INTERIOR SURFACE AT A MINIMUM.
MAGNETIC LAYER MAY BE APPLIED TO THE 30-DEGREE SIDE CUTS IF
POSSIBLE.
SHEET 1 SHEET 2 SHEET 3
OI
SHEET 4 SHEET 5 SHEET 6
REVISION HISTORY
REV ZONE DESCRIPTION DATE
Eng.
OI ALL
Original Issue 07/07/25
A. Davidson
R4.31
5.50
R
5.75
30°
10°
60°
30°
70°
MAGNETIC LAYER 15.00
Attachment (2) Document No. 5203ZN01 david.m.love Highlight