503-19-112 -CD- Drawings_Part1.pdf
PDF 31 MB Posted
- Attached to
- Z1DA--NRM | 503-19-112 Replace Steam System Project Federal contract opportunity
- Solicitation number
- 36C24424R0001
About this file
This document provides details on a federal contract opportunity from the Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 4. The solicitation number is 36C24424R0001 for the Z1DA--NRM | 503-19-112 Replace Steam System Project, which is currently in the pre-solicitation phase. The related file is 503-19-112 -CD- Drawings_Part1.pdf, a 31MB set of drawings for the project to replace the steam system. This opportunity will require contractors to replace an existing steam system and appears to include design and construction services. No other salient details are provided in this document.
View the file
Other files for this federal contract opportunity
Show all 14
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
2019 ADDITION
1962 ADDITION
ORIGINAL 1947 BUILDING
BUILDING 01
ADDITION
P la n N or th
True North
Drawing Title
VA FORM 08 - 6231
F
CONSULTANTS:
750 W HAMPDEN AVE
SUITE 300
ENGLEWOOD, CO 80110
(720) 550-6307 WWW.VALHALLAENGINEERING.COMDate:Issued:
10987654321
10987654321
E
D
C
B
A
F
E
D
C
B
A
ARCHITECT/ENGINEERS: STAMP:
Approved: Project Director
Phase Project Title
Location
Issue Date Checked Drawn
Project Number
Drawing Number
Building Number
C U s e rs
\V M
E
\D o c u m e n ts
\2 .1
A lt o o n a S te a m
V
E G
M E
P R m b ib le H
X D
.r v t
/9
/2
:2
:1
A
M
GI001
COVER REPLACE STEAM SYSTEMS
2907 PLEASANT VALLEY BLVD ALTOONA, PA 16602
503-19-112
06/09/2022 MB RL
100% CONSTRUCTION
DOCUMENT
VEG 20.14
JAMES E. VAN ZANDT VA MEDICAL CENTER
2907 PLEASANT VALLEY BLVD ALTOONA, PA 16602
VAMC PROJECT #: 503-19-112
REPLACE STEAM SYSTEMS
P la n N or th
True North
AREA OF WORK AERIAL IMAGE SHEET INDEX
GENERAL AREA OF WORK
BUILDING 01
SHEET NO. SHEET NAME
MP102 PLAN NORTH BASEMENT MECHANICAL NEW WORK PLAN
MP103 PLAN WEST BASEMENT MECHANICAL PIPING NEW WORK PLAN
MP104 PLAN EAST BASEMENT MECHANICAL NEW WORK PLAN
MP105 PLAN SOUTHWEST BASEMENT MECHANICAL NEW WORK PLAN
MP112 PLAN NORTH 1ST FLOOR MECHANICAL NEW WORK PLAN
MP113 PLAN WEST 1ST FLOOR MECHANICAL NEW WORK PLAN
MP114 PLAN EAST 1ST FLOOR MECHANICAL NEW WORK PLAN
MP115 PLAN SOUTHWEST 1ST FLOOR MECHANICAL NEW WORK PLAN
MP122 PLAN NORTH 2ND FLOOR MECHANICAL NEW WORK PLAN
MP123 PLAN WEST 2ND FLOOR MECHANICAL NEW WORK PLAN
MP124 PLAN EAST 2ND FLOOR MECHANICAL NEW WORK PLAN
MP125 PLAN SOUTHWEST 2ND FLOOR MECHANICAL NEW WORK PLAN
MP132 PLAN NORTH 3RD FLOOR MECHANICAL NEW WORK PLAN
MP133 PLAN WEST 3RD FLOOR MECHANICAL NEW WORK PLAN
MP134 PLAN EAST 3RD FLOOR MECHANICAL NEW WORK PLAN
MP142 PLAN NORTH 4TH FLOOR MECHANICAL NEW WORK PLAN
MP143 PLAN WEST 4TH FLOOR MECHANICAL NEW WORK PLAN
MP144 PLAN EAST 4TH FLOOR MECHANICAL NEW WORK PLAN
MP152 PLAN NORTH ROOF MECHANICAL NEW WORK PLAN
MP153 PLAN WEST 5TH FLOOR MECHANICAL NEW WORK PLAN
MP154 PLAN EAST 5TH FLOOR MECHANICAL NEW WORK PLAN
MP163 PLAN WEST 6TH FLOOR MECHANICAL NEW WORK PLAN
MP164 PLAN EAST 6TH FLOOR MECHANICAL NEW WORK PLAN
MP173 PLAN WEST 7TH FLOOR MECHANICAL NEW WORK PLAN
MP174 PLAN EAST 7TH FLOOR MECHANICAL NEW WORK PLAN
MP301 MECHANICAL ROOM ENLARGEMENTS
MP302 MECHANICAL ROOM ENLARGEMENT
MP303 MECHANICAL ROOM ENLARGEMENT
MP311 MECHANICAL ROOM SECTIONS
MP601 NEW STEAM SYSTEM RISER DIAGRAM
MP602 NEW STEAM SYSTEM RISER DIAGRAM
MP901 MECHANICAL AXONOMETRIC VIEWS - NEW WORK
ELECTRICAL
E-001 ELECTRICAL ABBREVIATIONS AND GENERAL NOTES
E-002 ELECTRICAL SYMBOLS
EP102 PLAN NORTH BASEMENT ELECTRICAL NEW WORK PLAN
EP103 PLAN WEST BASEMENT ELECTRICAL PLAN
EP104 BASEMENT ELECTRICAL POWER PLAN
EP105 PLAN SOUTHWEST BASEMENT ELECTRICAL PLAN
SHEET NO. SHEET NAME
GENERAL
GI001 COVER
GI101 BASEMENT LIFE SAFETY REFERENCE PLAN
GI111 1ST FLOOR LIFE SAFETY REFERENCE PLAN
GI121 2ND FLOOR LIFE SAFETY REFERENCE PLAN
GI131 3RD FLOOR LIFE SAFETY REFERENCE PLAN
GI141 4TH FLOOR LIFE SAFETY REFERENCE PLAN
GI151 5TH FLOOR LIFE SAFETY REFERENCE PLAN
GI161 6TH FLOOR LIFE SAFETY REFERENCE PLAN
GI171 7TH FLOOR LIFE SAFETY REFERENCE PLAN
GC001 PHASING SCHEDULE, NOTES, AND LEGEND
GC101 BASEMENT PHASING PLAN
GC111 1ST FLOOR PHASING PLAN
GC121 2ND FLOOR PHASING PLAN
GC131 3RD FLOOR PHASING PLAN
GC141 4TH FLOOR PHASING PLAN
GC151 5TH THROUGH 7TH FLOOR PHASING PLAN
ARCHITECTURAL
AE112 PLAN NORTH 1ST FLOOR ARCHITECTURAL PLAN
AE113 PLAN WEST 1ST FLOOR ARCHITECTURAL PLAN
AE114 PLAN EAST 1ST FLOOR ARCHITECTURAL PLAN
AE115 PLAN SOUTHWEST 1ST FLOOR ARCHITECTURAL PLAN
AE122 PLAN NORTH 2ND FLOOR ARCHITECTURAL PLAN
AE123 PLAN WEST 2ND FLOOR ARCHITECTURAL PLAN
AE124 PLAN EAST 2ND FLOOR ARCHITECTURAL PLAN
AE132 PLAN NORTH 3RD FLOOR ARCHITECTURAL PLAN
AE133 PLAN WEST 3RD FLOOR ARCHITECTURAL PLAN
AE134 PLAN EAST 3RD FLOOR ARCHITECTURAL PLAN
AE143 PLAN WEST 4TH FLOOR ARCHITECTURAL PLAN
AE153 PLAN WEST 5TH FLOOR ARCHITECTURAL PLAN
AE163 PLAN WEST 6TH FLOOR ARCHITECTURAL PLAN
AE411 ENLARGED PLANS
MECHANICAL
M-001 MECHANICAL ABBREVIATIONS AND GENERAL NOTES
M-002 MECHANICAL SYMBOLS AND LEGENDS
M-501 MECHANICAL DETAILS
M-502 MECHANICAL DETAILS
M-503 MECHANICAL DETAILS
M-601 MECHANICAL SCHEDULES
M-701 MECHANICAL CONTROLS
MD101 SUB-BASEMENT - STEAM PIPING DEMOLITION PLAN
MD102 PLAN NORTH BASEMENT - STEAM PIPING DEMOLITION PLAN
MD103 PLAN WEST BASEMENT- STEAM PIPING DEMOLITION PLAN
MD104 PLAN EAST BASEMENT - STEAM PIPING DEMOLITION PLAN
MD105 PLAN SOUTHWEST BASEMENT - STEAM PIPING DEMOLITION PLAN
MD112 PLAN NORTH 1ST FLOOR - STEAM PIPING DEMOLITION PLAN
MD113 PLAN WEST 1ST FLOOR - STEAM PIPING DEMOLITION PLAN
MD114 PLAN EAST 1ST FLOOR - STEAM PIPING DEMOLITION PLAN
MD115 PLAN SOUTHWEST 1ST FLOOR - STEAM PIPING DEMOLITION PLAN
MD122 PLAN NORTH 2ND FLOOR - STEAM PIPING DEMOLITION PLAN
MD123 PLAN WEST 2ND FLOOR - STEAM PIPING DEMOLITION PLAN
MD124 PLAN EAST 2ND FLOOR - STEAM PIPING DEMOLITION PLAN
MD125 PLAN SOUTHWEST 2ND FLOOR - STEAM PIPING DEMOLITION PLAN
MD132 PLAN NORTH 3RD FLOOR - STEAM PIPING DEMOLITION PLAN
MD133 PLAN WEST 3RD FLOOR - STEAM PIPING DEMOLITION PLAN
MD134 PLAN EAST 3RD FLOOR - STEAM PIPING DEMOLITION PLAN
MD135 PLAN SOUTHWEST 3RD FLOOR - STEAM PIPING DEMOLITION PLAN
MD142 PLAN NORTH 4TH FLOOR - STEAM PIPING DEMOLITION PLAN
MD143 PLAN WEST 4TH FLOOR - STEAM PIPING DEMOLITION PLAN
MD144 PLAN EAST 4TH FLOOR - STEAM PIPING DEMOLITION PLAN
MD152 PLAN NORTH ROOF - STEAM PIPING DEMOLITION PLAN
MD153 PLAN WEST 5TH FLOOR - STEAM PIPING DEMOLITION PLAN
MD154 PLAN EAST 5TH FLOOR - STEAM PIPING DEMOLITION PLAN
MD163 PLAN WEST 6TH FLOOR - STEAM PIPING DEMOLITION PLAN
MD164 PLAN EAST 6TH FLOOR - STEAM PIPING DEMOLITION PLAN
MD173 PLAN WEST 7TH FLOOR - STEAM PIPING DEMOLITION PLAN
MD174 PLAN EAST 7TH FLOOR - STEAM PIPING DEMOLITION PLAN
MD601 DEMO RISER DIAGRAM STEAM LOW PRESSURE
MD602 DEMO RISER DIAGRAM STEAM LOW PRESSURE
MD603 DEMO RISER DIAGRAM STEAM LOW PRESSURE
MD604 DEMO RISER DIAGRAM STEAM MEDIUM PRESSURE
MD605 DEMO RISER DIAGRAM STEAM MEDIUM PRESSURE
MD801 EXISTING MECHANICAL ROOM REFERENCE PHOTOS
MD901 MECHANICAL AXONOMETRIC VIEWS - EXISTING & DEMO
CONTRACTOR
PARKING
COORDINATE WITH
COR
DUMPSTER LOCATION
COORDINATE WITH COR
(LIMIT 1)
TRAILER LOCATION
COORDINATE WITH
COR (LIMIT 1)
ACCESS TO MECHANICAL ROOM
COORDINATE MATERIAL
LAYDOWN / TRANSPORT THRU
FACILITY WITH COR
06/09/2022
BA10
BB12
BE01E
BE01G
BE01D
BE01F
BE01C
BB15M
STAIR
FB
BB15G BB15H BB15I BB15J
BB15D
BA15A
AB-2
BA13
S4-2
P3-2
P2-2
SB01
BA10A
BC09
BC07
STAIR-2
CB-2
STAIR-2
BB-2
BB05
F5-2
BA05B
BA05A
STAIR-2
DB-2
BC11
BB08
BB08A
BA06 BA06A BA04
BA01
BB03
BB07
BB09
BB13A
BE01I
BE01J
BE01H
BE01B
STAIR
EB
BE01A
BE01
BE01K
BE01M
BA20
BB06
BA05
BA03
BC05
BC02
BC06
--2
BC04
BC01
BB16BB13
BB15B
BB15K
BA15
BA16
BA17
BB11BA18
BA21 BA22
BB16A
BC10A
BC08
BC10
BA11
BA11A
BB15A
BB15
BE01O
BE01N
BE01L
BC12
BC01A1
BC01A
BA02
BB15F
PLAN SOUTHEAST WING NOT IN SCOPE.
BA1BA2
BB01
BC1
BC12A
ZONE 1AB-01
BUSINESS AND OTHER USES
11092 SQ FT
ZONE 1AB-02
BUSINESS AND OTHER USES
9789 SQ FT
ZONE 1AB-03
BUSINESS AND OTHER USES
3476 SQ FT
ZONE 1AB-04
BUSINESS AND OTHER USES
11692 SQ FT
ZONE 1AB-05
BUSINESS AND OTHER USES
14789 SQ FT
LIFE SAFETY REFERENCE LEGEND
2-HOUR FIRE SEPARATION
1-HOUR FIRE SEPARATION
1-HOUR SMOKE BARRIER
0-HOUR SMOKE RESISTIVE
EXIT
CHUTES/ACCESS/DISCHARGE
HAZARDOUS AREA
NON-SLEEPING SUITE
KEY PLAN
GENERAL NOTES
P la n N or th
True North
BUILDING 1
Drawing Title
VA FORM 08 - 6231
F
CONSULTANTS:
750 W HAMPDEN AVE
SUITE 300
ENGLEWOOD, CO 80110
(720) 550-6307 WWW.VALHALLAENGINEERING.COMDate:Issued:
10987654321
10987654321
E
D
C
B
A
F
E
D
C
B
A
ARCHITECT/ENGINEERS: STAMP:
Approved: Project Director
Phase Project Title
Location
Issue Date Checked Drawn
Project Number
Drawing Number
Building Number
C U s e rs
\V M
E
\D o c u m e n ts
\2 .1
A lt o o n a S te a m
V
E G
M E
P R m b ib le H
X D
.r v t
/9
/2
:2
:1
A
M
GI101
BASEMENT LIFE SAFETY
REFERENCE PLAN
REPLACE STEAM SYSTEMS
2907 PLEASANT VALLEY BLVD ALTOONA, PA 16602
503-19-112
06/09/2022 MB RL
100% CONSTRUCTION
DOCUMENT
VEG 20.14
80'40'20'10'5'0'
P la n N or th
True North 1" = 20'-0"
BASEMENT FLOOR - LIFE SAFETY REFERENCE PLAN1
A. GI100-SERIES LIFE SAFETY PLANS HEREIN INDICATE EXISTING FIRE-
RESISTIVE WALLS AND AREA DATA AS PROVIDED BY THE VHA. REFER TO
MECHANICAL AND ELECTRICAL PLANS FOR SCOPE OF WORK. REFER TO
SPECIFICATIONS FOR REQUIREMENTS OF WORK THAT AFFECTS FIRE-
RESISTIVE CONSTRUCTION.
B. REFER TO 'GC' SERIES SHEETS FOR WORK PHASING REQUIREMENTS.
C. CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS AND REPORT
ANY DISCREPANCIES TO THE VHA COR BEFORE PROCEEDING WITH WORK.
D. REFER TO HAZARDOUS MATERIAL SURVEY IN THE SPECIFICATIONS. DO NOT
PROCEED WITH DEMOLITION OR DISTURBANCE OF ITEMS CONTAINING
HAZARDOUS MATERIALS UNTIL ABATEMENT IN ACCORDANCE WITH
HAZARDOUS MATERIAL ABATEMENT SPECIFICATIONS HAS BEEN
PERFORMED.
131F
131G
131D
129B 129A 129
LAUNDRY/STORAGE-1
141D
144A
145 145A 145B 146A
118A
116B
116C
101B
100B
118D-1
126 198B 198 198D 195B 195A
179B
179C
179D
179E
141C
141Q 141L
141B
141N 141E
STAIR-1
A1-1
140 140B
140C
132 134A
140A
141M 131K
131E
131A
127 S4-1
130A
130B
126A
116D
115A
116A
117A
120A
118 119
113B
STAIR-1
D1-1
102A
F5-1
147H 148
148D
147F
154153151 152
151A 152A 153A 156C
STAIR-1
C1-1
A124 A126
A125
A131
A127
A136 A137
A140
A134
STAIR-1
F1-1
A140A
A114
A111
A110
A112
A132
A115A116
A141
197A 195C196197198A
193K A107
A108A113193J
A117
A120 A119
A118
193H 193G 193E193F
193M193N
A130
A129
A123
A146
A101B
A106BA106C
A106D
A106E
A147A148B
A101D
183 185
158159
178159A
167 166
173 174 175
E1-1
MECHANICAL
ROOM-1
157E
157K
171-1
171A
A145
168169
147G
147C 147D
EXAM/TREATMENT-1
147E
STAIR-1
B1-1
131H
A106F
A144
157C160
A138E A138D A138C A138B
187A
187B
187C2A
187C2
131 CONTROL
RM-1
131C
131I131J
148A
P2-1
P3-1
P6-1
P7-1
180A
ER
WAITING-1
A101E
A106
A138G138F
A122B
A122C A122A
A139
156A
179G
156E
161A
179F
179F
193D 193D
193C
A143B
A105
147A
147B
148B
193A
193B
118C
102B
120B
100A
128B 128A
141C
141A
HALLWAY-1
187D
187C1A
187C1
156B
187C
A133
118D-2
179A
113A
ZONE 1A01-01
EXISTING HEALTH CARE
COMPLETE SPRINKLER PROTECTION
7724 SQ FT
ZONE 1A01-02
EXISTING HEALTH CARE
COMPLETE SPRINKLER PROTECTION
17886 SQ FT
ZONE 1A01-03
EXISTING HEALTH CARE
COMPLETE SPRINKLER PROTECTION
6049 SQ FT
ZONE 1A01-04
EXISTING HEALTH CARE
COMPLETE SPRINKLER PROTECTION
25405 SQ FT
ZONE 1A01-05
EXISTING HEALTH CARE
COMPLETE SPRINKLER PROTECTION
13924 SQ FT
ZONE 1A01-06
EXISTING HEALTH CARE
COMPLETE SPRINKLER PROTECTION
9691 SQ FT
ZONE 1A01-07
NEW HEALTH CARE
COMPLETE SPRINKLER PROTECTION
8121 SQ FT
ZONE 1A01-08
NEW HEALTH CARE
COMPLETE SPRINKLER PROTECTION
8970 SQ FT
LIFE SAFETY REFERENCE LEGEND
2-HOUR FIRE SEPARATION
1-HOUR FIRE SEPARATION
1-HOUR SMOKE BARRIER
0-HOUR SMOKE RESISTIVE
EXIT
CHUTES/ACCESS/DISCHARGE
HAZARDOUS AREA
NON-SLEEPING SUITE
KEY PLAN
GENERAL NOTES
P la n N or th
True North
BUILDING 1
Drawing Title
VA FORM 08 - 6231
F
CONSULTANTS:
750 W HAMPDEN AVE
SUITE 300
ENGLEWOOD, CO 80110
(720) 550-6307 WWW.VALHALLAENGINEERING.COMDate:Issued:
10987654321
10987654321
E
D
C
B
A
F
E
D
C
B
A
ARCHITECT/ENGINEERS: STAMP:
Approved: Project Director
Phase Project Title
Location
Issue Date Checked Drawn
Project Number
Drawing Number
Building Number
C U s e rs
\V M
E
\D o c u m e n ts
\2 .1
A lt o o n a S te a m
V
E G
M E
P R m b ib le H
X D
.r v t
/9
/2
:2
:2
A
M
GI111
1ST FLOOR LIFE SAFETY
REFERENCE PLAN
REPLACE STEAM SYSTEMS
2907 PLEASANT VALLEY BLVD ALTOONA, PA 16602
503-19-112
06/09/2022 MB RL
100% CONSTRUCTION
DOCUMENT
VEG 20.14
80'40'20'10'5'0'
P la n N or th
True North 1" = 20'-0"
1ST FLOOR - LIFE SAFETY REFERENCE PLAN1
A. GI100-SERIES LIFE SAFETY PLANS HEREIN INDICATE EXISTING FIRE-
RESISTIVE WALLS AND AREA DATA AS PROVIDED BY THE VHA. REFER TO
MECHANICAL AND ELECTRICAL PLANS FOR SCOPE OF WORK. REFER TO
SPECIFICATIONS FOR REQUIREMENTS OF WORK THAT AFFECTS FIRE-
RESISTIVE CONSTRUCTION.
B. REFER TO 'GC' SERIES SHEETS FOR WORK PHASING REQUIREMENTS.
C. CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS AND REPORT
ANY DISCREPANCIES TO THE VHA COR BEFORE PROCEEDING WITH WORK.
D. REFER TO HAZARDOUS MATERIAL SURVEY IN THE SPECIFICATIONS. DO NOT
PROCEED WITH DEMOLITION OR DISTURBANCE OF ITEMS CONTAINING
HAZARDOUS MATERIALS UNTIL ABATEMENT IN ACCORDANCE WITH
HAZARDOUS MATERIAL ABATEMENT SPECIFICATIONS HAS BEEN
2C08
2A21
2A21B 2A21A1
2A18 2A20
2A20C
2A06
2A17
2A16 2A15
2A12
2A13
2A11
2A08
2A10
2A07
2A09
STAIR
A2
2A05 2A04A
2A03B1
2A03B 2B01
2A03A
2A03C
2C03
2A04
2A11A
2A02
2B02 2B04
2B07
STAIR
C2
2C01
2C09
2C10
2C16A
2C12
2C16
2C17
2C18 2C21
2C08A 2C20
2B06C
2B06B 2B06A 2B06R 2B06P 2B06O
2B08 2B09
2B10
2B06N1
2B39
2B40
2B06N
STAIR
D2
STAIR
B2
2B41 2B42
2B53
2B55 2B56
2B56A
2B52
2B542B50
2B44 2B512B432B11 2B06S
2B06Q
2B06J 2B06G
2B06D 2B06L
2B06K2B06H2B06F2B06E
2B47
2B45 2B46
2B49
2B482B30D2 2B30D1
2B30D
2B30C
2B30B
2B29B2B29C
2B29D2B29E2B29F
2B29
2B30
2B30A
2B29A 2B29H
2B29G
2B29I
2B29K
2B29M
2B29Q
2B29R
2B29P
2B29S 2B29O 2B29U
2B38A
2B38
2B35 2B29T
2B29N
2B29L
2B29J
STAIR
E2
2B29W
2A14
2A3 2A03
2C05
2C06
2C04
2C11
2A17A
2A20A
2A21A
2A2
2A1
2B1
2B03
2B3
2B2
2B4
2B5
2C1
2C3
2C2
2A20B
ZONE 1A02-01
BUSINESS AND OTHER USES
9538 SQ FT
ZONE 1A02-02
BUSINESS AND OTHER USES
7038 SQ FT
ZONE 1A02-03
BUSINESS AND OTHER USES
3964 SQ FT
ZONE 1A02-04
BUSINESS AND OTHER USES
9398 SQ FT
ZONE 1A02-05
BUSINESS AND OTHER USES
10256 SQ FT
LIFE SAFETY REFERENCE LEGEND
2-HOUR FIRE SEPARATION
1-HOUR FIRE SEPARATION
1-HOUR SMOKE BARRIER
0-HOUR SMOKE RESISTIVE
EXIT
CHUTES/ACCESS/DISCHARGE
HAZARDOUS AREA
NON-SLEEPING SUITE
KEY PLAN
GENERAL NOTES
P la n N or th
True North
BUILDING 1
Drawing Title
VA FORM 08 - 6231
F
CONSULTANTS:
750 W HAMPDEN AVE
SUITE 300
ENGLEWOOD, CO 80110
(720) 550-6307 WWW.VALHALLAENGINEERING.COMDate:Issued:
10987654321
10987654321
E
D
C
B
A
F
E
D
C
B
A
ARCHITECT/ENGINEERS: STAMP:
Approved: Project Director
Phase Project Title
Location
Issue Date Checked Drawn
Project Number
Drawing Number
Building Number
C U s e rs
\V M
E
\D o c u m e n ts
\2 .1
A lt o o n a S te a m
V
E G
M E
P R m b ib le H
X D
.r v t
/9
/2
:2
:2
A
M
GI121
2ND FLOOR LIFE SAFETY
REFERENCE PLAN
REPLACE STEAM SYSTEMS
2907 PLEASANT VALLEY BLVD ALTOONA, PA 16602
503-19-112
06/09/2022 MB RL
100% CONSTRUCTION
DOCUMENT
VEG 20.14
80'40'20'10'5'0'
P la n N or th
True North 1" = 20'-0"
2ND FLOOR - LIFE SAFETY REFERENCE PLAN1
A. GI100-SERIES LIFE SAFETY PLANS HEREIN INDICATE EXISTING FIRE-
RESISTIVE WALLS AND AREA DATA AS PROVIDED BY THE VHA. REFER TO
MECHANICAL AND ELECTRICAL PLANS FOR SCOPE OF WORK. REFER TO
SPECIFICATIONS FOR REQUIREMENTS OF WORK THAT AFFECTS FIRE-
RESISTIVE CONSTRUCTION.
B. REFER TO 'GC' SERIES SHEETS FOR WORK PHASING REQUIREMENTS.
C. CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS AND REPORT
ANY DISCREPANCIES TO THE VHA COR BEFORE PROCEEDING WITH WORK.
D. REFER TO HAZARDOUS MATERIAL SURVEY IN THE SPECIFICATIONS. DO NOT
PROCEED WITH DEMOLITION OR DISTURBANCE OF ITEMS CONTAINING
HAZARDOUS MATERIALS UNTIL ABATEMENT IN ACCORDANCE WITH
HAZARDOUS MATERIAL ABATEMENT SPECIFICATIONS HAS BEEN
STAIR
C3
3C11
3C15
3C18
3C20
3C24
3C28
3C27
3C25
3C21
3C17
3C16
3C10
3C08
3C07
3A053A07
3A10
3A113A153A163A20
3A22
3A21 3A19
3A17
3A14 3A13 3A12 3A09 3A06 3A04
3C05
3C04
3C03
3C02 3B01
3B02
3B03
3B06 3B05
3B08 3B07
3B09 3B10
3A03
3C09
3C13
3C14
3C18A
3C19
3C22A
3C23
3C26
STAIR
D3
3C22
3C28A
3C21A
3C16A
3A15A 3A11A 3A07A
STAIR
A3
3A22A 3A08 3A02 3A01
3B01A
3B01B
3B01B1 3B01C 3E03
3E013E01A
3E02
3E02A
3F15 3F16 3F18 3F20
3F21
3F19
3F17 3F14
3F24
3F13
3F12
3F11
3F10
3FO9
3F05
3E05
3E05D
3E04C 3E04B
3E04
3E04A
STAIR
B3
3E05C
3E05B
3E05A
3F08B 3F08A
3F08 3F01
3F02
3B09A 3B11
3B15
3B16
3B18
3B20
3B21 3B22E
3B22E1
3B19
3B17
3B14
3B13
3B12
3B22F
3B22 3B22A
3B22B 3B22C 3B22D 3B22G 3B22H
3F22
3F23
3F12A
3F25
3F11A 3F11A1
3F10A1
3F10A
3F26
3F06
3F06A 3F05A
3F07
STAIR
E3
3C12
3A18
3C01
3F04
3F04A
3F03
3C28B
3C1
3A13A2
3C2
3B1
3B2
3F1
3E01B
ZONE 1A03-01
EXISTING HEALTH CARE
COMPLETE SPRINKLER PROTECTION
4521 SQ FT
ZONE 1A03-02
EXISTING HEALTH CARE
COMPLETE SPRINKLER PROTECTION
3131 SQ FT
ZONE 1A03-03
EXISTING HEALTH CARE
COMPLETE SPRINKLER PROTECTION
6320 SQ FT
ZONE 1A03-04
EXISTING HEALTH CARE
COMPLETE SPRINKLER PROTECTION
7438 SQ FT
ZONE 1A03-05
EXISTING HEALTH CARE
COMPLETE SPRINKLER PROTECTION
12688 SQ FT
LIFE SAFETY REFERENCE LEGEND
2-HOUR FIRE SEPARATION
1-HOUR FIRE SEPARATION
1-HOUR SMOKE BARRIER
0-HOUR SMOKE RESISTIVE
EXIT
CHUTES/ACCESS/DISCHARGE
HAZARDOUS AREA
NON-SLEEPING SUITE
KEY PLAN
GENERAL NOTES
P la n N or th
True North
BUILDING 1
Drawing Title
VA FORM 08 - 6231
F
CONSULTANTS:
750 W HAMPDEN AVE
SUITE 300
ENGLEWOOD, CO 80110
(720) 550-6307 WWW.VALHALLAENGINEERING.COMDate:Issued:
10987654321
10987654321
E
D
C
B
A
F
E
D
C
B
A
ARCHITECT/ENGINEERS: STAMP:
Approved: Project Director
Phase Project Title
Location
Issue Date Checked Drawn
Project Number
Drawing Number
Building Number
C U s e rs
\V M
E
\D o c u m e n ts
\2 .1
A lt o o n a S te a m
V
E G
M E
P R m b ib le H
X D
.r v t
/9
/2
:2
:2
A
M
GI131
3RD FLOOR LIFE SAFETY
REFERENCE PLAN
REPLACE STEAM SYSTEMS
2907 PLEASANT VALLEY BLVD ALTOONA, PA 16602
503-19-112
06/09/2022 MB RL
100% CONSTRUCTION
DOCUMENT
VEG 20.14
80'40'20'10'5'0'
P la n N or th
True North 1" = 20'-0"
3RD FLOOR - LIFE SAFETY REFERENCE PLAN1
A. GI100-SERIES LIFE SAFETY PLANS HEREIN INDICATE EXISTING FIRE-
RESISTIVE WALLS AND AREA DATA AS PROVIDED BY THE VHA. REFER TO
MECHANICAL AND ELECTRICAL PLANS FOR SCOPE OF WORK. REFER TO
SPECIFICATIONS FOR REQUIREMENTS OF WORK THAT AFFECTS FIRE-
RESISTIVE CONSTRUCTION.
B. REFER TO 'GC' SERIES SHEETS FOR WORK PHASING REQUIREMENTS.
C. CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS AND REPORT
ANY DISCREPANCIES TO THE VHA COR BEFORE PROCEEDING WITH WORK.
D. REFER TO HAZARDOUS MATERIAL SURVEY IN THE SPECIFICATIONS. DO NOT
PROCEED WITH DEMOLITION OR DISTURBANCE OF ITEMS CONTAINING
HAZARDOUS MATERIALS UNTIL ABATEMENT IN ACCORDANCE WITH
HAZARDOUS MATERIAL ABATEMENT SPECIFICATIONS HAS BEEN
4C01A4C01
4C03
4C02
4A064A074A084A10
4A12
4A13
4A15
4A16
4A18
4A16A
4A18A
4A22A
4A22
STAIR
A4
4A21
4A21A
4A17
4A17A 4A14 4A14A 4A11 4A11A 4A09A 4A09 4A05A
4A05
4A03A
4A03
4A03B 4B05
4B05A
4B10 4B14
4B14A
4B17 4B21A
4B21
4B24 4B26 4B24A
4B28
4B274B25A4B25
4B234B22
STAIR
B4
4B184B16A4B164B134B11
4B094B06
4B04
4B02
STAIR
C4
4A19
4B08
4A04
4A01
STAIR
E4
4A14A2 4B1
ZONE 1A04-01
EXISTING HEALTH CARE
COMPLETE SPRINKLER PROTECTION
4094 SQ FT
ZONE 1A04-02
EXISTING HEALTH CARE
COMPLETE SPRINKLER PROTECTION
4970 SQ FT
ZONE 1A04-03
EXISTING HEALTH CARE
COMPLETE SPRINKLER PROTECTION
4712 SQ FT
ZONE 1A04-04
EXISTING HEALTH CARE
COMPLETE SPRINKLER PROTECTION
9125 SQ FT
LIFE SAFETY REFERENCE LEGEND
2-HOUR FIRE SEPARATION
1-HOUR FIRE SEPARATION
1-HOUR SMOKE BARRIER
0-HOUR SMOKE RESISTIVE
EXIT
CHUTES/ACCESS/DISCHARGE
HAZARDOUS AREA
NON-SLEEPING SUITE
KEY PLAN
GENERAL NOTES
P la n N or th
True North
BUILDING 1
Drawing Title
VA FORM 08 - 6231
F
CONSULTANTS:
750 W HAMPDEN AVE
SUITE 300
ENGLEWOOD, CO 80110
(720) 550-6307 WWW.VALHALLAENGINEERING.COMDate:Issued:
10987654321
10987654321
E
D
C
B
A
F
E
D
C
B
A
ARCHITECT/ENGINEERS: STAMP:
Approved: Project Director
Phase Project Title
Location
Issue Date Checked Drawn
Project Number
Drawing Number
Building Number
C U s e rs
\V M
E
\D o c u m e n ts
\2 .1
A lt o o n a S te a m
V
E G
M E
P R m b ib le H
X D
.r v t
/9
/2
:2
:2
A
M
GI141
4TH FLOOR LIFE SAFETY
REFERENCE PLAN
REPLACE STEAM SYSTEMS
2907 PLEASANT VALLEY BLVD ALTOONA, PA 16602
503-19-112
06/09/2022 MB RL
100% CONSTRUCTION
DOCUMENT
VEG 20.14
48'24'12'6'3'0'
P la n N or th
True North 3/32" = 1'-0"
4TH FLOOR - LIFE SAFETY REFERENCE PLAN1
A. GI100-SERIES LIFE SAFETY PLANS HEREIN INDICATE EXISTING FIRE-
RESISTIVE WALLS AND AREA DATA AS PROVIDED BY THE VHA. REFER TO
MECHANICAL AND ELECTRICAL PLANS FOR SCOPE OF WORK. REFER TO
SPECIFICATIONS FOR REQUIREMENTS OF WORK THAT AFFECTS FIRE-
RESISTIVE CONSTRUCTION.
B. REFER TO 'GC' SERIES SHEETS FOR WORK PHASING REQUIREMENTS.
C. CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS AND REPORT
ANY DISCREPANCIES TO THE VHA COR BEFORE PROCEEDING WITH WORK.
D. REFER TO HAZARDOUS MATERIAL SURVEY IN THE SPECIFICATIONS. DO NOT
PROCEED WITH DEMOLITION OR DISTURBANCE OF ITEMS CONTAINING
HAZARDOUS MATERIALS UNTIL ABATEMENT IN ACCORDANCE WITH
HAZARDOUS MATERIAL ABATEMENT SPECIFICATIONS HAS BEEN
5C01
5A055A065A08
5A095A10
5A13
5A14 5A165A175A20
5A19 5A15 5A11 5A07 5A07A 5A03 5B03 5B07 5B08 5B11
5B13 5B16 5B19
5B21
5B185B17
5B15
5B125B105B095B06
5B05
5B04
5A01A 5A02
STAIR
C5
STAIR
B5
STAIR
A5
5A19A 5A15A 5A11A 5B03A 5B07A 5B08A 5B11A 5B13A
5B16A 5B19A
5B18A5B17A
5B10A
5B09A5B06A
5B02
5A16A
5A12
5A04
5A01
5B20
5B01
5A1
5A2 5B1 5B2
ZONE 1A05-01
NEW HEALTH CARE
2600 SQ FT
ZONE 1A05-02
NEW HEALTH CARE
5287 SQ FT
ZONE 1A05-03
NEW HEALTH CARE
4712 SQ FT
LIFE SAFETY REFERENCE LEGEND
2-HOUR FIRE SEPARATION
1-HOUR FIRE SEPARATION
1-HOUR SMOKE BARRIER
0-HOUR SMOKE RESISTIVE
EXIT
CHUTES/ACCESS/DISCHARGE
HAZARDOUS AREA
NON-SLEEPING SUITE
KEY PLAN
GENERAL NOTES
P la n N or th
True North
BUILDING 1
Drawing Title
VA FORM 08 - 6231
F
CONSULTANTS:
750 W HAMPDEN AVE
SUITE 300
ENGLEWOOD, CO 80110
(720) 550-6307 WWW.VALHALLAENGINEERING.COMDate:Issued:
10987654321
10987654321
E
D
C
B
A
F
E
D
C
B
A
ARCHITECT/ENGINEERS: STAMP:
Approved: Project Director
Phase Project Title
Location
Issue Date Checked Drawn
Project Number
Drawing Number
Building Number
C U s e rs
\V M
E
\D o c u m e n ts
\2 .1
A lt o o n a S te a m
V
E G
M E
P R m b ib le H
X D
.r v t
/9
/2
:2
:3
A
M
GI151
5TH FLOOR LIFE SAFETY
REFERENCE PLAN
REPLACE STEAM SYSTEMS
2907 PLEASANT VALLEY BLVD ALTOONA, PA 16602
503-19-112
06/09/2022 MB RL
100% CONSTRUCTION
DOCUMENT
VEG 20.14
48'24'12'6'3'0'
P la n N or th
True North 3/32" = 1'-0"
5TH FLOOR - LIFE SAFETY REFERENCE PLAN1
A. GI100-SERIES LIFE SAFETY PLANS HEREIN INDICATE EXISTING FIRE-
RESISTIVE WALLS AND AREA DATA AS PROVIDED BY THE VHA. REFER TO
MECHANICAL AND ELECTRICAL PLANS FOR SCOPE OF WORK. REFER TO
SPECIFICATIONS FOR REQUIREMENTS OF WORK THAT AFFECTS FIRE-
RESISTIVE CONSTRUCTION.
B. REFER TO 'GC' SERIES SHEETS FOR WORK PHASING REQUIREMENTS.
C. CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS AND REPORT
ANY DISCREPANCIES TO THE VHA COR BEFORE PROCEEDING WITH WORK.
D. REFER TO HAZARDOUS MATERIAL SURVEY IN THE SPECIFICATIONS. DO NOT
PROCEED WITH DEMOLITION OR DISTURBANCE OF ITEMS CONTAINING
HAZARDOUS MATERIALS UNTIL ABATEMENT IN ACCORDANCE WITH
HAZARDOUS MATERIAL ABATEMENT SPECIFICATIONS HAS BEEN
6A06
6A08
6A09
6A10
6A11
6A13
6A146A166A196A21
6A20 6A15 6A12
6A16A
STAIR
A6
6A20A 6A15A 6A12A
6A07A
6A07B
6C01
STAIR
C6
6A02
6A07 6A05 6A03 6B03 6B04 6B07 6B09
6B12
6B14 6B17
6B18
6B166B15
6B13
6B106B086B066B05
6B02 6A01B
6B03A 6B04A 6B07A 6B09A
6B06A6B05A
6B02A
6B14A 6B17A
6B15A 6B16ASTAIR
B6
6A01
6A14A
6A17
6B01
6B12B
6B12A
6A1
6A2 6B1
ZONE 1A06-01
NEW HEALTH CARE
2983 SQ FT
ZONE 1A06-02
NEW HEALTH CARE
5970 SQ FT
ZONE 1A06-03
NEW HEALTH CARE
4634 SQ FT
LIFE SAFETY REFERENCE LEGEND
2-HOUR FIRE SEPARATION
1-HOUR FIRE SEPARATION
1-HOUR SMOKE BARRIER
0-HOUR SMOKE RESISTIVE
EXIT
CHUTES/ACCESS/DISCHARGE
HAZARDOUS AREA
NON-SLEEPING SUITE
KEY PLAN
GENERAL NOTES
P la n N or th
True North
BUILDING 1
Drawing Title
VA FORM 08 - 6231
F
CONSULTANTS:
750 W HAMPDEN AVE
SUITE 300
ENGLEWOOD, CO 80110
(720) 550-6307 WWW.VALHALLAENGINEERING.COMDate:Issued:
10987654321
10987654321
E
D
C
B
A
F
E
D
C
B
A
ARCHITECT/ENGINEERS: STAMP:
Approved: Project Director
Phase Project Title
Location
Issue Date Checked Drawn
Project Number
Drawing Number
Building Number
C U s e rs
\V M
E
\D o c u m e n ts
\2 .1
A lt o o n a S te a m
V
E G
M E
P R m b ib le H
X D
.r v t
/9
/2
:2
:3
A
M
GI161
6TH FLOOR LIFE SAFETY
REFERENCE PLAN
REPLACE STEAM SYSTEMS
2907 PLEASANT VALLEY BLVD ALTOONA, PA 16602
503-19-112
06/09/2022 MB RL
100% CONSTRUCTION
DOCUMENT
VEG 20.14
48'24'12'6'3'0'
P la n N or th
True North 3/32" = 1'-0"
6TH FLOOR - LIFE SAFETY REFERENCE PLAN1
A. GI100-SERIES LIFE SAFETY PLANS HEREIN INDICATE EXISTING FIRE-
RESISTIVE WALLS AND AREA DATA AS PROVIDED BY THE VHA. REFER TO
MECHANICAL AND ELECTRICAL PLANS FOR SCOPE OF WORK. REFER TO
SPECIFICATIONS FOR REQUIREMENTS OF WORK THAT AFFECTS FIRE-
RESISTIVE CONSTRUCTION.
B. REFER TO 'GC' SERIES SHEETS FOR WORK PHASING REQUIREMENTS.
C. CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS AND REPORT
ANY DISCREPANCIES TO THE VHA COR BEFORE PROCEEDING WITH WORK.
D. REFER TO HAZARDOUS MATERIAL SURVEY IN THE SPECIFICATIONS. DO NOT
PROCEED WITH DEMOLITION OR DISTURBANCE OF ITEMS CONTAINING
HAZARDOUS MATERIALS UNTIL ABATEMENT IN ACCORDANCE WITH
HAZARDOUS MATERIAL ABATEMENT SPECIFICATIONS HAS BEEN
OFFICE
7B27
CHIEF OF
STAFF
7B26
CHIEF OF
STAFF
SECRETARY
7B25
HEALTH
SYSTEMS
SPECIALIST
CHIEF OF
STAFF
7B24
CORRIDOR
7B2
COMPLIANCE
OFFICER
AND GROUP
PRACTICE
MANAGER
7B22
DIRECTOR
7B19
STAIR
B7-2
EXECUTIVE
ASSISTANT
TO THE
DIRECTOR
7B16
DIRECTOR
SECRETARY
7B17
ASSOCIATE
DIRECTOR
SECRETARY
7B15
ASSOCIATE
DIRECTOR
7B12
WAITING
AREA
7B13
DIRECTORS
OFFICE
PROGRAM
SUPPORT
ASSISTANT
7B11
ASSOCIATE
DIRECTOR
FOR PATIENT
/ NURSING
SERVICES
7B06
ADMINISTRATIVE
OFFICER
PATIENT /
NURSING
SERVICES
7B08
PRIVACY /
FOIA OFFICE
7B07
ASSOCIATE
DIRECTOR
FOR PATIENT
/ NURSING
SERVICES
7B05
PRIVACY
SPECIALIST
7B04
PUBLIC
AFFAIRS
PROGRAM
SUPPORT
ASSISTANT
7B01
DIRECTOR'S
CONFERENCE
ROOM
7A02
PUBLIC
AFFAIRS
OFFICER
7B02
STAIR
C7-2
PROGRAM
ANALYST
DIRECTORS
OFFICE
7C02
CONFERENCE
ROOM
7C01
VENDING
7A05
WOMENS
RESTROOM,
ADA
7A09
PROGRAM
SPECIALIST
7A14
ROOM
7A16
MENS
RESTROOM,
ADA
7A12
ACCREDITATION
SPECIALIST
7A15
INFECTION
CONTROL/
PREVENTION
NURSE/
MDRO
COORDINATOR
7A17
RISK
MANAGER/
UTILIZATION
REVIEW
NURSE
7A20
PATIENT
SAFETY
MANAGER
7A19
SYSTEM
REDESIGN
COORDINATOR
7A21
STAIR
A7-2
CHIEF,
QUALITY
MANAGEMENT
SERVICE
7A23
QUALITY
MANAGEMENT
PROGRAM
SUPPORT
ASSISTANT
7A18
KITCHEN
AREA
7A03
STORAGE
7A07STORAGE
7A11
STORAGE
7A13
TELECOM
7A01
STORAGE
7B10
STORAGE
ROOM
7B14
RESTROOM
7B16A
STORAGE
7B18
ELEC
7B21
RESTROOM
7B12A
MAIL /
COPIER
ROOM
7A22
HOUSEKEEPING
7A24
Space
1F128
LIFE SAFETY REFERENCE LEGEND
2-HOUR FIRE SEPARATION
1-HOUR FIRE SEPARATION
1-HOUR SMOKE BARRIER
0-HOUR SMOKE RESISTIVE
EXIT
CHUTES/ACCESS/DISCHARGE
HAZARDOUS AREA
NON-SLEEPING SUITE
KEY PLAN
GENERAL NOTES
P la n N or th
True North
BUILDING 1
Drawing Title
VA FORM 08 - 6231
F
CONSULTANTS:
750 W HAMPDEN AVE
SUITE 300
ENGLEWOOD, CO 80110
(720) 550-6307 WWW.VALHALLAENGINEERING.COMDate:Issued:
10987654321
10987654321
E
D
C
B
A
F
E
D
C
B
A
ARCHITECT/ENGINEERS: STAMP:
Approved: Project Director
Phase Project Title
Location
Issue Date Checked Drawn
Project Number
Drawing Number
Building Number
C U s e rs
\V M
E
\D o c u m e n ts
\2 .1
A lt o o n a S te a m
V
E G
M E
P R m b ib le H
X D
.r v t
/9
/2
:2
:3
A
M
GI171
7TH FLOOR LIFE SAFETY
REFERENCE PLAN
REPLACE STEAM SYSTEMS
2907 PLEASANT VALLEY BLVD ALTOONA, PA 16602
503-19-112
06/09/2022 MB RL
100% CONSTRUCTION
DOCUMENT
VEG 20.14
A. GI100-SERIES LIFE SAFETY PLANS HEREIN INDICATE EXISTING FIRE-
RESISTIVE WALLS AND AREA DATA AS PROVIDED BY THE VHA. REFER TO
MECHANICAL AND ELECTRICAL PLANS FOR SCOPE OF WORK. REFER TO
SPECIFICATIONS FOR REQUIREMENTS OF WORK THAT AFFECTS FIRE-
RESISTIVE CONSTRUCTION.
B. REFER TO 'GC' SERIES SHEETS FOR WORK PHASING REQUIREMENTS.
C. CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS AND REPORT
ANY DISCREPANCIES TO THE VHA COR BEFORE PROCEEDING WITH WORK.
D. REFER TO HAZARDOUS MATERIAL SURVEY IN THE SPECIFICATIONS. DO NOT
PROCEED WITH DEMOLITION OR DISTURBANCE OF ITEMS CONTAINING
HAZARDOUS MATERIALS UNTIL ABATEMENT IN ACCORDANCE WITH
HAZARDOUS MATERIAL ABATEMENT SPECIFICATIONS HAS BEEN
PERFORMED.
48'24'12'6'3'0'
P la n N or th
True North 3/32" = 1'-0"
7TH FLOOR LIFE SAFETY REFERENCE PLAN1
RM NAME
RM#
RM NAME
RM#
Y.Y.Y
X.X.X
PHASING ZONE TAG,
TYPICAL. REFER TO
PHASING SCHEDULE ON
SHEET GI101.
PHASING ZONE
APPLICABLE SHADED
AREA, TYPICAL.
PHASING ZONE
BOUNDARY,
TYPICAL.
PHASING PLANS LEGEND
TEMPORARY CONSTRUCTION
PARTITION AND/OR INFECTION
CONTROL BARRIER. REF PLAN
KEYNOTES.
GENERAL NOTES
Drawing Title
VA FORM 08 - 6231
F
CONSULTANTS:
750 W HAMPDEN AVE
SUITE 300
ENGLEWOOD, CO 80110
(720) 550-6307 WWW.VALHALLAENGINEERING.COMDate:Issued:
10987654321
10987654321
E
D
C
B
A
F
E
D
C
B
A
ARCHITECT/ENGINEERS: STAMP:
Approved: Project Director
Phase Project Title
Location
Issue Date Checked Drawn
Project Number
Drawing Number
Building Number
C U s e rs
\V M
E
\D o c u m e n ts
\2 .1
A lt o o n a S te a m
V
E G
M E
P R m b ib le H
X D
.r v t
/9
/2
:2
:3
A
M
GC001
PHASING SCHEDULE, NOTES, AND
LEGEND
REPLACE STEAM SYSTEMS
2907 PLEASANT VALLEY BLVD ALTOONA, PA 16602
503-19-112
06/09/2022 MB RL
100% CONSTRUCTION
DOCUMENT
VEG 20.14
PHASING SCHEDULE
PHASING
ZONE ZONE DESCRIPTION
ICRA
CLASS
PHASING
SEQUENCE
ALLOWABLE
WORK
HOURS
FOOT
NOTES
B.A.1
MAIN STEAM ENTRANCE MECH RM
BA10 & SUBBASEMENT
III 1 N/A 1,2,3,4
B.A.2 BASEMENT MAIL ROOM & CORRIDOR III 2 6PM-6AM 4
B.A.3 BASEMENT SHOPS III 3 6PM-6AM 4
B.A.4 BASEMENT BIOMED III 4 6PM-6AM 4
B.C.1 BASEMENT CANTEEN III 5 6PM-6AM 4
B.C.2 BASEMENT MECH BC11 III 6 N/A 2,4,5
B.B.1 BASEMENT MISC. III 7 6PM-6AM 4
B.B.2 BASEMENT MECH BB12 III 8 N/A 2,3,4
B.B.3 BASEMENT MECH BB15F III 9 N/A 2,3,4,5
B.B.4 BASEMENT CRAWLSPACE III 10 N/A 4
B.E.3 BASEMENT 1984 III 11 6PM-6AM 4
B.E.1 BASEMENT MECH BE01F&01B III 11 N/A 2
1.E.2 LAUNDRY III 12 4PM-6AM 4
1.E.1 1ST FLOOR RADIOLOGY III 13 6PM-6AM 4,7
1.D.3 1ST FLOOR PLAN SOUTH WING IV 14 6PM-6AM 4,7
1.G.1
1ST FLOOR CENTRAL CORRIDOR &
OFFICES
IV 15 6PM-6AM 4,7
1.F.3 1ST FLOOR ER ENTRANCE IV 16 10PM-6AM 4,6
1.G.2 1ST FLOOR MECH 1G10 III 17 N/A 4,5
1.F.1 1ST FLOOR PLAN NORTH WING IV 18 6PM-6AM 4,7
1.F.2 1ST FLOOR MECH 1F69 III 19 N/A 1,3,4
2.A.1
2ND FLOOR KITCHEN & LOADING
DOCK
III 20 3PM-6AM 4,7
2.C.1 2ND FLOOR PLAN SOUTH WING III 21 6PM-6AM 4,7
2.B.1 2ND FLOOR PLAN NORTHEAST WING IV 22 6PM-6AM 4,7
3.A.1 3RD FLOOR PLAN WEST WING III 23 6PM-6AM 4,7
3.C.1 3RD FLOOR PLAN SOUTH WING IV 24 6PM-6AM 4
3.B.1
3RD FLOOR TELEHEALTH & SURGERY
PREP
IV 25 6PM-6AM 4,6
3.F.1 3RD FLOOR SURGERY IV 26 6PM-6AM 4,6
3.E.1 3RD FLOOR SPS IV 27 6PM-6AM 4,6,7,8
4.A.1 4TH FLOOR PLAN WEST INPATIENT III 28 8AM-8PM 4,7,9
4.C.1 4TH FLOOR INPATIENT SUPPORT III 29 8AM-8PM 4,7
4.B.1 4TH FLOOR PLAN EAST INPATIENT III 30 8AM-8PM 4,7,9
4.D.1 4TH FLOOR MECH 400 III 31 N/A 4,5
5.A.1 5TH FLOOR PLAN WEST INPATIENT III 32 8AM-8PM 4,7,9
5.A.2 5TH FLOOR INPATIENT SUPPORT III 33 8AM-8PM 4,7
5.B.1 5TH FLOOR PLAN EAST INPATIENT III 34 8AM-8PM 4,7,9
5.B.2 5TH FLOOR PLAN EAST INPATIENT III 35 8AM-8PM 4,7,9
5.B.3 5TH FLOOR PLAN EAST INPATIENT III 36 8AM-8PM 4,7,9
6.A.1 6TH FLOOR PLAN WEST INPATIENT III 37 8AM-8PM 4,7,9
6.A.2 6TH FLOOR INPATIENT SUPPORT III 38 8AM-8PM 4,7
6.B.1 6TH FLOOR PLAN EAST INPATIENT III 39 8AM-8PM 4,7,9
6.B.2 6TH FLOOR PLAN EAST INPATIENT III 40 8AM-8PM 4,7,9
7.A.1 7TH FLOOR PLAN WEST III 41 6PM-6AM 4,7
7.A.2 7TH FLOOR PLAN SOUTH III 42 6PM-6AM 4,7
7.B.1 7TH FLOOR PLAN EAST III 43 6PM-6AM 4,7
7.B.2 7TH FLOOR PLAN EAST III 44 6PM-6AM 4,7
A. PHASING PLANS HEREIN ARE INTENDED FOR GENERAL GUIDANCE AND
RESOURCE ALLOCATION. FINAL ZONE PHASING ORDER WILL BE
DISCUSSED IN THE PRECONSTRUCTION MEETING FOLLOWING CONTRACT
AWARD. CONTRACTOR SHALL SUBMIT A PHASING PLAN WITH DETAILED
METHOD OF PROCEDURE FOR EACH PHASE, FOR REVIEW AND APPROVAL
BY THE VHA PRIOR TO COMMENCING WORK.
B. ANY CONCERNS OR OBJECTIONS TO MEETING ALL PHASING
REQUIREMENTS HEREIN MUST BE PROVIDED IN WRITING PRIOR TO
BIDDING. OTHERWISE, THE AWARDED CONTRACTOR IS RESPONSIBLE
FOR MEETING ALL REQUIREMENTS, OR MAKING ALTERNATIVE
ARRANGEMENTS TO MEET THE INTENT OF THE REQUIREMENTS TO THE
SATISFACTION OF THE VHA COR, AT NO ADDITIONAL COST TO THE
GOVERNMENT.
C. A TOTAL SYSTEM OUTAGE OF UP TO 8 HOURS MAY BE SCHEDULED WITH
THE VHA COR ON A WEEKEND BETWEEN 6 PM AND 6 AM TO INITIALLY CUT
IN VALVES IN THE SYSTEM TO ENABLE CONTINUED OPERATION
THROUGHOUT ALL PHASES, WITH MINIMAL LOCALIZED OUTAGES AS
ALLOWED PER THE PHASING SCHEDULE.
D. DO NOT PROCEED WITH WORK IN THE NEXT PHASE UNTIL WORK IN THE
PRECEDING PHASE HAS BEEN COMPLETED AND ACCEPTED IN WRITING
BY THE VHA COR.
E. PROVIDE ISOLATION VALVES AND PRESSURIZATION CONNECTIONS FOR
NEW PIPES ENTERING AND EXITING ALL PHASING ZONES SUCH THAT THE
NEW PIPING SPECIFIC TO A COMPLETED ZONE MAY BE TESTED ALONE IN
ACCORDANCE WITH THE SPECIFICATIONS PRIOR TO PLACING BACK IN
SERVICE. PIPE TESTING PER SPECIFICATIONS OF EACH ZONE SHALL BE
INCLUDED IN THE ALLOCATED PHASING TIME FRAME FOR EACH PHASING
ZONE.
F. ALL CONTRACTOR WORK, INCLUDING SET-UP, TAKE-DOWN, AND
CLEANING OF THE AREA TO THE PREVIOUS OCCUPIED CONDITIONS
SHALL OCCUR BETWEEN THE WORK HOURS NOTED FOR EACH PHASING
ZONE, UNLESS SPECIFICALLY AUTHORIZED OTHERWISE IN WRITING BY
THE VHA COR. ZONES SUCH AS MECHANICAL ROOMS WITH WORK HOURS
NOTED "N/A" MAY BE WORKED IN AT ANY TIME, SUBJECT TO APPLICABLE
FOOTNOTED RESTRICTIONS FOR MINIMIZING DOWNTIME AND KEEPING
DOWNSTREAM SYSTEMS IN SERVICE.
G. UNLESS OTHERWISE NOTED, NEIGHBORING PHASING ZONES WITH
SIMILAR ALLOWABLE WORK HOURS MAY BE COMPLETED
SIMULTANEOUSLY PROVIDED 2 WEEK PRIOR WRITTEN NOTICE IS GIVEN
TO THE VHA COR.
H. PROVIDE TEMPORARY CONSTRUCTION PARTITIONS AND/OR INFECTION
CONTROL BARRIERS AS APPLICABLE AT BOUNDARIES OF ACTIVE
PHASING ZONES OR AFFECTED WORK AREA(S) DURING WORK HOURS.
REFER TO SPECIFICATIONS 01 35 26 FOR BARRIER AND OTHER
REQUIREMENTS OF APPLICABLE ICRA CLASSIFICATIONS. COORDINATE
BARRIER LOCATIONS AND CONSTRUCTION WITH THE VHA COR AND THE
VHA INFECTION CONTROL OFFICER. ICRA CLASSIFICATIONS IN PHASING
SCHEDULE ARE FOR INITIAL REFERENCE ONLY. COMPLETE ICRA PERMIT
FOR EACH WORK AREA IN CONSULTATION WITH THE VHA FOR OFFICIAL
CLASSIFICATIONS PRIOR TO START OF WORK.
I. NO WORK SHALL OCCUR DURING THE TWO WEEKS PER YEAR DURING A
JCAHO INSPECTION.
J. PROVIDE SMOKE TIGHT SEPARATION BETWEEN ACTIVE PHASING ZONES
AND ADJACENT OCCUPIED AREAS. VERIFY INTEGRITY OF EXISTING
SMOKE PARTITIONS. PROVIDE TEMPORARY CONSTRUCTION PARTITIONS
TO MAINTAIN SMOKE SEPARATION WHERE EXISTING SEPARATIONS IS
COMPROMISED OR NON-EXISTING, IN ACCORDANCE WITH
SPECIFICATIONS. ADDITIONALLY PROVIDE 1-HR FIRE PROTECTION IF
SPRINKLERS ARE TO BE IMPAIRED IN THE AREA OF WORK.
1. PROVIDE TEMPORARY BYPASS FOR DOMESTIC WATER HEATERS TAKEN
OUT OF SERVICE FOR MORE THAN 4 HOURS. ALLOCATE MANPOWER AS
REQUIRED TO PERFORM BYPASS SWITCHOVERS AND FINAL TIE-INS TO
STEAM SYSTEM WITHIN A 4-HOUR SHUTDOWN WINDOW.
2. PROVIDE TEMPORARY CONDENSATE PUMP FOR DURATION OF
CONDENSATE PUMP REPLACEMENT. INCLUDE TEMPORARY POWER
PROVISIONS AS NECESSARY ALONG WITH SUPERVISION.
3. PERFORM HW HX AND HW PUMP REPLACEMENTS, AND/OR STEAM PIPING
REPLACEMENTS TO HW HXs, SUCH THAT HW FROM AT LEAST ONE HX IS
AVAILABLE TO THE HW LOOP WITHOUT INTERRUPTION FOR MORE THAN 4
HOURS, UNLESS PERFORMED FROM JUNE THROUGH SEPTEMBER,
INCLUSIVE.
4. PROVIDE TEMPORARY BYPASS FOR STEAM MAINS PASSING THROUGH
THE PHASING ZONE TO DOWNSTREAM EQUIPMENT, SUCH THAT
DOWNSTREAM MAINS REMAIN IN SERVICE WITHOUT INTERRUPTION FOR
MORE THAN 4 HOURS.
5. PROVIDE TEMPORARY BYPASS TO AHU HEATING COIL AND HUMIDIFIER
SUCH THAT STEAM IS AVAILABLE TO THE UNIT WITHOUT INTERRUPTION
FOR MORE THAN 4 HOURS. HEATING COIL MAY BE TAKEN OFFLINE FOR
LONGER IF PERFORMED FROM JUNE THROUGH SEPTEMBER, INCLUSIVE.
6. OVERALL ZONE MUST STAY IN CONTINUED OPERATION. PROVIDE
TEMPORARY BARRIERS AROUND LOCAL AREAS OF WORK OR UTILIZE
HEPA CARTS. COORDINATE WITH SITE IN WRITING AT LEAST ONE WEEK
IN ADVANCE OF START IN A NEW LOCATION TO FACILITATE RELOCATION
OF PERSONNEL AND EQUIPMENT BY THE SITE AS NEEDED.
7. PERFORM TIE-INS OF NEW RADIANT CEILING PANELS INTO EXISTING HW
LOOP SUCH THAT HW SERVICE TO AREAS BEYOND THE ACTIVE PHASING
ZONE IS NOT INTERRUPTED FOR MORE THAN 4 HOURS, UNLESS
PERFORMED FROM JUNE THROUGH SEPTEMBER, INCLUSIVE.
8. MAXIMUM ALLOWABLE STERILIZER DOWNTIME IS 4 HOURS. OTHERWISE,
CONTRACTOR SHALL PROVIDE TEMPORARY CLEAN STEAM GENERATOR
TO MAINTAIN OPERATIONS, INCLUDING ALL REQUIRED CONNECTIONS,
POWER, ETC.
9. PERFORM WORK IN ONE INPATIENT ROOM AT A TIME AND ONLY DURING
DAY HOURS AS SCHEDULED TO MINIMIZE DISTURBANCE TO RESIDENTS.
COORDINATE WITH SITE IN WRITING AT LEAST ONE WEEK IN ADVANCE OF
START IN A NEW ROOM TO FACILITATE RELOCATION OF RESIDENTS,
PERSONNEL, AND EQUIPMENT BY THE SITE AS NEEDED.
PHASING GENERAL NOTES
PHASING SCHEDULE FOOTNOTES
MECHANICAL
ROOM
BA10
MECHANICAL
ROOM
BB12
STORAGE,
GENERAL /
CAGE
BE01E
DAV
STORAGE /
CAGE
BE01G
POLICE
TRAINING
BE01D
MECHANICAL
ROOM
BE01F
ELEVATOR
PIT
BE01C
ELEC
BB15M
STAIR
FB
OFFICE
BB15G
OFFICE
BB15H
OFFICE
BB15I
OFFICE
BB15J
UTILITY
SYSTEMS
SHOP
BB15D
RESTROOM
BA15A
STAIR-2
AB-2
ELECTRICAL
RM
BA13
ELEV.-2
S4-2
ELEV.-2
P3-2
ELEV.-2
P2-2
SUB-BASEMENT
SB01
STORAGE
BA10A
ELECTRICAL
CLOSET
BC07
STAIR-2
CB-2
STAIR-2
BB-2
SIGN SHOP
BB05
ELEV.-2
F5-2
MENS
SHOWER
BA05B
MENS
RESTROOM
BA05A
CLOSET
BC08A
STAIR-2
DB-2
HVAC
BC11
CANTEEN
SERVICE
STORAGE
BB08
CANTEEN
OFFICE
BB08A
MAIL ROOM
BA06
OFFICE
BA06A
STORAGE
BA04
FIRE CLOSET
BA01
EMERGENCY
WHEELCHAIR
BB03
ELECTRICAL
CLOSET
BB07
STORAGE
A&MM
BB09
STORAGE,
EQUIPMENT
BB13A
MECHANICAL
ROOM
BE01I
ELEVATOR
PIT
BE01J
STORAGE,
EQUIPMENT /
CAGE
BE01H
MECHANICAL
ROOM
BE01B
STAIR
EB
STORAGE,
FILE RM /
CAGE
BE01A
STORAGE,
EQUIPMENT
BE01
STORAGE,
EQUIPMENT /
CAGE
BE01K
STORAGE,
EQUIPMENT /
CAGE
BE01M
MACHINE
SHOP
BA20
PATRIOT
STORE
STORAGE
BB06
FIRE ALARM
ROOM
BB04
MENS
LOCKER
ROOM STAFF
ONLY
BA05
CANTEEN
STORAGE
BA03
CREDIT
UNION
OFFICE
BC05
STORAGE
CLOSET
BC03
PATRIOT
STORE
BC02
RESTROOM,
ADA
BC06
ELEVATOR
LOBBY
--2
DINING
ROOM VCS
BC04
CANTEEN
BC01
HAC
STORAGE
BB16
HAC
BB13
STORAGE
BB15B
STORAGE
BB15K
STORAGE
BA15
PAINT SHOP
BA16
ELECTRICAL
SHOP
BA17
COMPUTER
ROOM
BB11
FIRE CLOSET
BB14
PLUMBING
SHOP
BA18
CARPENTER
SHOP
BA21
LOCKSMITH
BA22
CRAWL
SPACE
BB16A
CREDIT
UNION
MANAGER
OFFICE
BC10A
CREDIT
UNION
OFFICE
BC08
CREDIT
UNION
BC10
MECHANICAL
ROOM
BA11
STORAGE/EQUIPMENT
BA11A
HOUSEKEEPING
SHOP
BB15A
STORAGE,
WARD
SUPPLIES
BB15
STORAGE,
EQUIPMENT /
CAGE
BE01O
STORAGE,
GENERAL /
CAGE
BE01N
STORAGE,
GENERAL /
CAGE
BE01L
STORAGE,
CREDIT
UNION /
RESTRICTED
AREA
BC12
FREEZER
BC01A1
COOLER
BC01A
BIO-MED &
TELECOM
TECHNICIAN
BA02
MECHANICAL
BB15F
PLAN SOUTHEAST WING NOT IN SCOPE.
B.A.1
B.A.4
CORRIDOR
BA1
CORRIDOR
BA2
ROOM
BB01
CORRIDOR
BC1
B.B.2
B.B.1
B.C.2
B.C.1
B.B.3
B.E.3
B.E.1
B.A.3
B.A.2
INCLUDE SUB-BASEMENT
PIPING IN THIS PHASE.
B.B.4
CRAWLSPACE
BC12A
EXISTING
STEP 1
STEP 2
STEP 3A
STEP 3B,
3C, etc.
STEP 4
6" MPS MAIN MPS BRANCH, SIZE VARIES
NEW PARALLEL 6" MPS MAIN
TERMINATE IN CAPPED LINE-SIZE VALVES
EXISTING MPS MAIN AND
BRANCHES REMAIN IN SERVICE
BRIEF COORDINATED SHUTDOWN OF
MPS SYSTEM NOT TO EXCEED 8 HOURS
AND ON WEEKENDS
CUT LINE-SIZE VALVES INTO EXISTING BRANCHES
ISOLATE BRANCH FROM EXISTING MAIN
EXISTING MPS MAIN AND REMAINING
BRANCHES REMAIN IN SERVICE
CONNECT BRANCH TO NEW LIVE PARALLEL MAIN DURING BRIEF
COORDINATED SHUTDOWN OF BRANCH NOT TO EXCEED 8 HOURS AND
ON WEEKENDS.
REPEAT STEP 3A FOR REMAINING BRANCHES
BRANCHES AND NEW PARALLEL MAIN REMAIN
IN SERVICE
INSTALL NEW 6" MAIN WHILE ISOLATED
MEDIUM PRESSURE STEAM BASEMENT MAIN PIPING PHASING PLAN
GENERAL: DIAGRAMS BELOW ARE FOR GENERAL PHASING CONCEPT ONLY. REFER TO MECHANICAL PLANS, DETAILS, AND SPECIFICATIONS FOR SPECIFIC PIPE ACCESSORIES, SIZES, QUANTITIES, AND ROUTING REQUIREMENTS.
B.E.1
PHOTOS OF POSSIBLE CONTRACTOR ENTRANCE FOR LARGE PIPE SECTIONS SHOWN FOR
REFERENCE ONLY.
TYP
00KEYNOTES
KEY PLAN
P la n N or th
True North
BUILDING 1
Drawing Title
VA FORM 08 - 6231
F
CONSULTANTS:
750 W HAMPDEN AVE
SUITE 300
ENGLEWOOD, CO 80110
(720) 550-6307 WWW.VALHALLAENGINEERING.COMDate:Issued:
10987654321
10987654321
E
D
C
B
A
F
E
D
C
B
A
ARCHITECT/ENGINEERS: STAMP:
Approved: Project Director
Phase Project Title
Location
Issue Date Checked Drawn
Project Number
Drawing Number
Building Number
C U s e rs
\V M
E
\D o c u m e n ts
\2 .1
A lt o o n a S te a m
V
E G
M E
P R m b ib le H
X D
.r v t
/9
/2
:2
:4
A
M
GC101
BASEMENT PHASING PLAN REPLACE STEAM SYSTEMS
2907 PLEASANT VALLEY BLVD ALTOONA, PA 16602
503-19-112
06/09/2022 MB RL
100% CONSTRUCTION
DOCUMENT
VEG 20.14
64'32'16'8'4'0'
1/16" = 1'-0"
BASEMENT PHASING PLAN1
PHASING GENERAL NOTES
1. PROVIDE INFECTION CONTROL BARRIER AT APPROXIMATE LOCATION
SHOWN. REF SPECIFICATION 01 35 26.
2. TYPICAL FOR ALL WELDING WORK WITHIN PHASING ZONES: REF
SPECIFICATION 01 35 26 HOT WORK REQUIREMENTS.
3. INFECTION CONTROL BARRIERS AND TEMPORARY CONSTRUCTION
PARTITIONS ARE INDICATED ON PLANS FOR GENERAL GUIDANCE ONLY.
SUBMIT PROPOSED FINAL LOCATIONS, TYPES, CONSTRUCTIONS,
DOORWAYS, EXIT ROUTES, SIGNAGE, ETC WITH PHASING PLAN FOR VHA
APPROVAL PRIOR TO START OF WORK. COMPLY WITH SPECIFICATION 01
35 26 AND APPLICABLE REQUIREMENTS OF INTERIM LIFE SAFETY
MEASURE (ILSM) EVALUATION (SPECIFICATION SECTION 01 00 02) AS
COMPLETED FOR EACH AREA AND PHASE OF WORK.
A. PHASING PLANS HEREIN ARE INTENDED FOR GENERAL GUIDANCE AND
RESOURCE ALLOCATION. FINAL ZONE PHASING ORDER WILL BE
DISCUSSED IN THE PRECONSTRUCTION MEETING FOLLOWING CONTRACT
AWARD. CONTRACTOR SHALL SUBMIT A PHASING PLAN WITH DETAILED
METHOD OF PROCEDURE FOR EACH PHASE, FOR REVIEW AND APPROVAL
BY THE VHA PRIOR TO COMMENCING WORK.
B. ANY CONCERNS OR OBJECTIONS TO MEETING ALL PHASING
REQUIREMENTS HEREIN MUST BE PROVIDED IN WRITING PRIOR TO
BIDDING. OTHERWISE, THE AWARDED CONTRACTOR IS RESPONSIBLE
FOR MEETING ALL REQUIREMENTS, OR MAKING ALTERNATIVE
ARRANGEMENTS TO MEET THE INTENT OF THE REQUIREMENTS TO THE
SATISFACTION OF THE VHA COR, AT NO ADDITIONAL COST TO THE
GOVERNMENT.
C. A TOTAL SYSTEM OUTAGE OF UP TO 8 HOURS MAY BE SCHEDULED WITH
THE VHA COR ON A WEEKEND BETWEEN 6 PM AND 6 AM TO INITIALLY CUT
IN VALVES IN THE SYSTEM TO ENABLE CONTINUED OPERATION
THROUGHOUT ALL PHASES, WITH MINIMAL LOCALIZED OUTAGES AS
ALLOWED PER THE PHASING SCHEDULE.
D. DO NOT PROCEED WITH WORK IN THE NEXT PHASE UNTIL WORK IN THE
PRECEDING PHASE HAS BEEN COMPLETED AND ACCEPTED IN WRITING
BY THE VHA COR.
E. PROVIDE ISOLATION VALVES AND PRESSURIZATION CONNECTIONS FOR
NEW PIPES ENTERING AND EXITING ALL PHASING ZONES SUCH THAT THE
NEW PIPING SPECIFIC TO A COMPLETED ZONE MAY BE TESTED ALONE IN
ACCORDANCE WITH THE SPECIFICATIONS PRIOR TO PLACING BACK IN
SERVICE. PIPE TESTING PER SPECIFICATIONS OF EACH ZONE SHALL BE
INCLUDED IN THE ALLOCATED PHASING TIME FRAME FOR EACH PHASING
ZONE.
F. ALL CONTRACTOR WORK, INCLUDING SET-UP, TAKE-DOWN, AND
CLEANING OF THE AREA TO THE PREVIOUS OCCUPIED CONDITIONS
SHALL OCCUR BETWEEN THE WORK HOURS NOTED FOR EACH PHASING
ZONE, UNLESS SPECIFICALLY AUTHORIZED OTHERWISE IN WRITING BY
THE VHA COR. ZONES SUCH AS MECHANICAL ROOMS WITH WORK HOURS
NOTED "N/A" MAY BE WORKED IN AT ANY TIME, SUBJECT TO APPLICABLE
FOOTNOTED RESTRICTIONS FOR MINIMIZING DOWNTIME AND KEEPING
DOWNSTREAM SYSTEMS IN SERVICE.
G. UNLESS OTHERWISE NOTED, NEIGHBORING PHASING ZONES WITH
SIMILAR ALLOWABLE WORK HOURS MAY BE COMPLETED
SIMULTANEOUSLY PROVIDED 2 WEEK PRIOR WRITTEN NOTICE IS GIVEN
TO THE VHA COR.
H. PROVIDE TEMPORARY CONSTRUCTION PARTITIONS AND/OR INFECTION
CONTROL BARRIERS AS APPLICABLE AT BOUNDARIES OF ACTIVE
PHASING ZONES OR AFFECTED WORK AREA(S) DURING WORK HOURS.
REFER TO SPECIFICATIONS 01 35 26 FOR BARRIER AND OTHER
REQUIREMENTS OF APPLICABLE ICRA CLASSIFICATIONS. COORDINATE
BARRIER LOCATIONS AND CONSTRUCTION WITH THE VHA COR AND THE
VHA INFECTION CONTROL OFFICER. ICRA CLASSIFICATIONS IN PHASING
SCHEDULE ARE FOR INITIAL REFERENCE ONLY. COMPLETE ICRA PERMIT
FOR EACH WORK AREA IN CONSULTATION WITH THE VHA FOR OFFICIAL
CLASSIFICATIONS PRIOR TO START OF WORK.
I. NO WORK SHALL OCCUR DURING THE TWO WEEKS PER YEAR DURING A
JCAHO INSPECTION.
J. PROVIDE SMOKE TIGHT SEPARATION BETWEEN ACTIVE PHASING ZONES
AND ADJACENT OCCUPIED AREAS. VERIFY INTEGRITY OF EXISTING
SMOKE PARTITIONS. PROVIDE TEMPORARY CONSTRUCTION PARTITIONS
TO MAINTAIN SMOKE SEPARATION WHERE EXISTING SEPARATIONS IS
COMPROMISED OR NON-EXISTING, IN ACCORDANCE WITH
SPECIFICATIONS. ADDITIONALLY PROVIDE 1-HR FIRE PROTECTION IF
SPRINKLERS ARE TO BE IMPAIRED IN THE AREA OF WORK.
TYP
PLAN SOUTHEAST WING NOT IN SCOPE.
MRI ROOM
1E21
MRI
CONTROL
ROOM
1E23
CT OFFICE
1E17A
ULTRASOUND
ROOM
1E09
OFFICE
1E08
TECHNICIAN
WORKSTATION
1E06
LAUNDRY/STORAGE
1E35
WOMENS
LOCKER
ROOM
1E30
CHIEF OF
RADIOLOGY
1E28
OFFICE
1E26
BONE
DENSITOMETRY
1E25
RADIOLOGY
RECEPTION
1E24A
WOMENS
VETERANS
HEALTHCARE
OFFICE
1D07
HBOC
OFFICE
1D06
RESPIRATORY
THERAPY
1D12
SOCIAL
WORKER
OFFICE
1D17
OFFICE
1D18
CRNP RM
1D24
EXAM/OFFICE
1D30
EXAM
1D32
EXAM/OFFICE
1D33
OFFICE
1D35
AUDIOLOGY
CLINIC
1D37
AUDIOLOGY
1D39
EXAM
1D36
EXAM
1D34
EXAM
1D31
EXAM
1D28
PACT CARE
MANAGER
OFFICE/CRASH
CART
1D27
STAFF
BREAK
ROOM
1D20
EQUIPMENT
RM
1D14A
CLERK
WORKSTATION
1D14
WAITING
1D08
CHEST RM
1E05
ACUTE LONG
TERM CARE
CHIEF
OFFICE
1G19B
ACUTE &
LONG TERM
CARE
SERVICE &
OUTPATIENT
SERVICE
1G19
OFFICE
1G19A
HOMELESS
COORDINATOR
OFFICE
1G14B
HOMELESS
COORDINATOR
OFFICE
1G14A
EXAM RM
1F57
EXAM RM
1F56
EXAM RM
1F55
EXAM RM
1F46
OFFICE
1E35C
VETERANS
BENEFITS
OFFICE
1E34A
DAV
VETERANS
BENEFITS
1E34 PATIENT
CLOTHING
1E35A
OXYGEN
STORAGE
1E38SOAP ROOM
1E36A
STAIR
A1-2
MORGUE
1E37
MECHANICAL
ROOM
1E37A1
STAFF
RESTROOM
1E37A2
RADIOLOGY
SUPERVISOR
1E29
RESTROOM,
ADA
1E11B
STORAGE
1E11A
AUTOPSY
1E37A
FILM
STORAGE
1E39
MEDS
1E16
MRI
EQUIPMENT
ROOM
1E20
RESTROOM,
ADA
1E14
R&F RM #2
1E11
LINEN CHUTE
COLLECTION
AREA
1E27
R&F RM #1
1E07
ELEV.
2B61
STORAGE
1E13ELECTRICAL
CLOSET
1E15
EXAM/OFF
1D16
RESTROOM
1D23
STAFF
RESTROOM,
ADA
1D21
EXAM/OFFICE
1D15
STAFF
RESTROOM
1D10A
PULMONARY
FUNCTION
LAB
1D10
VFW
SERVICE
OFFICE
1D04
OFFICE
1D11
VETERANS
BENEFITS
COUNSELING
1D09
PSYCHOLOGIST/
NEUROPSYCHOLOGIST
OFFICE
1D05
FAMILY
RESTROOM,
ADA
1D02
FAMILY
RESTOOM,
ADA
1D01
ELEC
1D38
AUDIOLOGY
TECHNICIAN
OFFICE
1D25
HAC
1D22
STAIR
D1-2
DIRTY
UTILITY
1D26
ELEV.
2B58
ELECTRICAL
CLOSET
1E32
VLER OFFICE
1E31
CBOC RM
1E33
RESTROOM,
ADA
1E03B
CPAC
CUSTOMER
SERVICE
1E01
FIRE CLOSET
1E02
EXAM
1E03C
CASHIER
1F02
OFFICE
1F06
PHARMACY
SERVICE
ADMIN.
1F05
OFFICE
1F03
OFFICE
1F04
OFFICE
1F03A1
OFFICE
1F03A
PHARMACY
CHIEF
1F05A
CONFERENCE/
BREAK RM
1F07A
STAIR
C1-2
CLEAN
UTILITY
1A35
SOILED
UTILITY
1A33
MED RM
1A34
EXAM/OFF.
1A29
EXAM
1A32
EXAM
1A24
EXAM
1A21 OXYGEN
STOR.
1A12
EXAM/OFFICE
1A26
STAIR
F1-2
ELEC CL
1A12A
CLOSET
1A19A
EXAM
1A14
EXAM
1A15
EXAM
1A13
EXAM
1A28
EXAM
1A22
EXAM/OFFICE
1A23
EMPTY O2
CYLINDERS
1A07
MENS
RESTROOM,
ADA
1G18
HOMELESS
CASE
MANAGER
OFFICE
1G14C
COPY
1G16
WOMENS
RESTROOM,
ADA
1G17
ELEC
CLOSET
1G19C ROOM
1G12A
ON-CALL
1A19
PATIENT
ADVOCATE
OFFICE
1A17
OFFICE
1A17A
UNION
OFFICE
1G15
WAITING
1A38
RESTROOM,
ADA
1A39
STAFF
RESTROOM,
ADA
1A40 CONFERENCE
ROOM
1A41
EXAM
1G12B
SECRETARY
1G12C
EXAM
1G12G
EXAM
1G12E
OXYG.
1G12F
SU
1G12H
EXAM
1A30
EXAM
1A31
STAFF RM
1A36
MED RM
1A10A
NOD
1A03D
OPERATOR
1A03C
STAFF
RESTROOM,
ADA
1A03B
OFFICE
1A03A
ROI OFF.
1A18
CLEAN HOLD
1A10B
OFFICE
1A16
AOD/
STORAGE
1A03E
HAC
1G05
ELEC
1G03
MENS
RESTROOM,
ADA
1G08
OFFICE
1F54
PATIENT
TOILET
1F43
OFFICE
1F47
EXAM
1F48
OFFICE
1F44
RESTROOM,
ADA
1F48A
EXAM
1F58
ELEC
1F62
ELEC
1F60
EXAM
1F49
PSYCHOLOGIST
OFFICE
1F66
EXAM
1F64
EXAM
1F61
HAC
1F73
EXAM
1F71
STAIR
E1-3
MECHANICAL
ROOM
1G10
VAULT
1F10D
PHARMACY
OFFICE
1F68
CONSULT
COORDINATOR
OFFICE
1F67
STORAGE
1F10E
MECHANICAL
RM
1F69
MECH
1F69A
STAFF
CORRIDOR
1D3
TRIAGE
1A04
MEDS
1F70
CLEAN STOR.
1F72
EXAM
1F63
EXAM
1F65
SOIL. LINEN
1F51
HOMELESS
COORDINATOR
SUITE
1G14
CARDIOLOGY
STORAGE
1E03E
EXAM
1E03D
EXAM
1E03F EXAM/TREATMENT
1E03G
STAIR
B1-2
RADIOLOGY
WAITING
1E2
PREP ROOM
1E22
RADIOLOGY
CHECK-IN
1E24
ROI
1A20
UCC
1A05
HAC
1F10C
EXAM
1F50
RX PICK-UP
1F08
BED
1A09D
BED
1A09C
BED
1A09B
BED
1A09A
MULTI-PURPOSE
RM
1G02A
DETECTIVE
INTERVIEW
ROOM
1G02G
OPERATIONS
1G02E
POLICE
RECEPT.
1G02
CARDIOLOGY
LAB
1E03
CAT SCAN
1E12
CONTROL
RM
1E17
LOCKER
ROOM
1E18
LOCKER
ROOM
1E19
1F01
ELEV.
2B60
ELEV.
2B59
ELEV.
P6-2
ELEV.
P7-2
COFFEE
SHOP
1G01
WAITING
1F09
ER WAITING
1A01
CENTRAL
REGISTRATION
1A03
NOURISHMENT
1A08
NURSE
STATION
1A10
DISCHARGE
1A37A
CHECK-OUT
1A37
DISCHARGE
1A37B
RESTROOM,
ADA
1A11
CONSULT
1F08A
CHECK-IN
1F42
ANTE/IV
ROOM
1F10A
PHARMACY
1F10
STAFF/
CONFERENCE
1F53
CONFERENCE
ROOM
1F53B
CHECK-OUT/BLUE
TEAM CLERK
1F45
CHECK-OUT/
BLUE TEAM
CLERK
1F43
OFFICE
1G07EXAM
1G12I
OFFICE
1G06
CORRIDOR
1A1
REGISTRATION
1A02
CARDIOLOGY
WORKSTATIONS
1E03A
CARDIOLOGY
WORKSTATIONS
1E03A1
CORRIDOR
148B
COMPENSATION
& PENSION
1G12
RECEPTION
1G12D
CORRIDOR
118C
CORRIDOR
COPIER
ALCOVE
1D27A
CORRIDOR
120B
CLERK/OFFICE
1D14
ULTRASOUND
ROOM
1E10
ULTRASOUND
ROOM
128A
WASH ROOM
1E36
WASH ROOM
141A
HALLWAY
187D
ARMORY
1G02F1
LOCKERS
1G02F
RX
DROP-OFF
1F08B
WOMENS
RESTROOM,
ADA
1G09
OPERATIONS
1G02D
EXAM/OFFICE
1A27
CORRIDOR
1E1
ROOM
1F59
Space
198E
UNKNOWN
1D29
1.E.1
1.E.2
1.D.3
1.G.1
1.G.2
1.F.1
1.F.2
1.F.3
TYP
00KEYNOTES
KEY PLAN
P la n N or th
True North
BUILDING 1
Drawing Title
VA FORM 08 - 6231
F
CONSULTANTS:
750 W HAMPDEN AVE
SUITE 300
ENGLEWOOD, CO 80110
(720) 550-6307 WWW.VALHALLAENGINEERING.COMDate:Issued:
10987654321
10987654321
E
D
C
B
A
F
E
D
C
B
A
ARCHITECT/ENGINEERS: STAMP:
Approved: Project Director
Phase Project Title
Location
Issue Date Checked Drawn
Project Number
Drawing Number
Building Number
C U s e rs
\V M
E
\D o c u m e n ts
\2 .1
A lt o o n a S te a m
V
E G
M E
P R m b ib le H
X D
.r v t
/9
/2
:2
:5
A
M
GC111
1ST FLOOR PHASING PLAN REPLACE STEAM SYSTEMS
2907 PLEASANT VALLEY BLVD ALTOONA, PA 16602
503-19-112
06/09/2022 MB RL
100% CONSTRUCTION
DOCUMENT
VEG 20.14
64'32'16'8'4'0'
1/16" = 1'-0"
1ST FLOOR PHASING PLAN1
PHASING GENERAL NOTES
1. PROVIDE INFECTION CONTROL BARRIER AT APPROXIMATE LOCATION
SHOWN. REF SPECIFICATION 01 35 26.
2. PROVIDE TEMPORARY CONSTRUCTION PARTITION AT APPROXIMATE
LOCATION SHOWN FOR SMOKE SEPARATION OF PHASING ZONES IF
COMPLETED SEPARATELY. PROVIDE DOORS TO MATCH EXISTING DOOR
LOCATIONS BETWEEN PHASE AREAS. PARTITIONS SHALL ALSO COMPLY
WITH ICRA REQUIREMENTS. REF SPECIFICATION 01 35 26.
3. INFECTION CONTROL BARRIERS AND TEMPORARY CONSTRUCTION
PARTITIONS ARE INDICATED ON PLANS FOR GENERAL GUIDANCE ONLY.
SUBMIT PROPOSED FINAL LOCATIONS, TYPES, CONSTRUCTIONS,
DOORWAYS, EXIT ROUTES, SIGNAGE, ETC WITH PHASING PLAN FOR VHA
APPROVAL PRIOR TO START OF WORK. COMPLY WITH SPECIFICATION 01
35 26 AND APPLICABLE REQUIREMENTS OF INTERIM LIFE SAFETY
MEASURE (ILSM) EVALUATION (SPECIFICATION SECTION 01 00 02) AS
COMPLETED FOR EACH AREA AND PHASE OF WORK. REFER TO GI SHEET
SERIES FOR EXISTING LIFE SAFETY PLANS INCLUDING EXISTING WALL
RATINGS AND EXITS ROUTES.
A. PHASING PLANS HEREIN ARE INTENDED FOR GENERAL GUIDANCE AND
RESOURCE ALLOCATION. FINAL ZONE PHASING ORDER WILL BE
DISCUSSED IN THE PRECONSTRUCTION MEETING FOLLOWING CONTRACT
AWARD. CONTRACTOR SHALL SUBMIT A PHASING PLAN WITH DETAILED
METHOD OF PROCEDURE FOR EACH PHASE, FOR REVIEW AND APPROVAL
BY THE VHA PRIOR TO COMMENCING WORK.
B. ANY CONCERNS OR OBJECTIONS TO MEETING ALL PHASING
REQUIREMENTS HEREIN MUST BE PROVIDED IN WRITING PRIOR TO
BIDDING. OTHERWISE, THE AWARDED CONTRACTOR IS RESPONSIBLE
FOR MEETING ALL REQUIREMENTS, OR MAKING ALTERNATIVE
ARRANGEMENTS TO MEET THE INTENT OF THE REQUIREMENTS TO THE
SATISFACTION OF THE VHA COR, AT NO ADDITIONAL COST TO THE
GOVERNMENT.
C. A TOTAL SYSTEM OUTAGE OF UP TO 8 HOURS MAY BE SCHEDULED WITH
THE VHA COR ON A WEEKEND BETWEEN 6 PM AND 6 AM TO INITIALLY CUT
IN VALVES IN THE SYSTEM TO ENABLE CONTINUED OPERATION
THROUGHOUT ALL PHASES, WITH MINIMAL LOCALIZED OUTAGES AS
ALLOWED PER THE PHASING SCHEDULE.
D. DO NOT PROCEED WITH WORK IN THE NEXT PHASE UNTIL WORK IN THE
PRECEDING PHASE HAS BEEN COMPLETED AND ACCEPTED IN WRITING
BY THE VHA COR.
E. PROVIDE ISOLATION VALVES AND PRESSURIZATION CONNECTIONS FOR
NEW PIPES ENTERING AND EXITING ALL PHASING ZONES SUCH THAT THE
NEW PIPING SPECIFIC TO A COMPLETED ZONE MAY BE TESTED ALONE IN
ACCORDANCE WITH THE SPECIFICATIONS PRIOR TO PLACING BACK IN
SERVICE. PIPE TESTING PER SPECIFICATIONS OF EACH ZONE SHALL BE
INCLUDED IN THE ALLOCATED PHASING TIME FRAME FOR EACH PHASING
ZONE.
F. ALL CONTRACTOR WORK, INCLUDING SET-UP, TAKE-DOWN, AND
CLEANING OF THE AREA TO THE PREVIOUS OCCUPIED CONDITIONS
SHALL OCCUR BETWEEN THE WORK HOURS NOTED FOR EACH PHASING
ZONE, UNLESS SPECIFICALLY AUTHORIZED OTHERWISE IN WRITING BY
THE VHA COR. ZONES SUCH AS MECHANICAL ROOMS WITH WORK HOURS
NOTED "N/A" MAY BE WORKED IN AT ANY TIME, SUBJECT TO APPLICABLE
FOOTNOTED RESTRICTIONS FOR MINIMIZING DOWNTIME AND KEEPING
DOWNSTREAM SYSTEMS IN SERVICE.
G. UNLESS OTHERWISE NOTED, NEIGHBORING PHASING ZONES WITH
SIMILAR ALLOWABLE WORK HOURS MAY BE COMPLETED
SIMULTANEOUSLY PROVIDED 2 WEEK PRIOR WRITTEN NOTICE IS GIVEN
TO THE VHA COR.
H. PROVIDE TEMPORARY CONSTRUCTION PARTITIONS AND/OR INFECTION
CONTROL BARRIERS AS APPLICABLE AT BOUNDARIES OF ACTIVE
PHASING ZONES OR AFFECTED WORK AREA(S) DURING WORK HOURS.
REFER TO SPECIFICATIONS 01 35 26 FOR BARRIER AND OTHER
REQUIREMENTS OF APPLICABLE ICRA CLASSIFICATIONS. COORDINATE
BARRIER LOCATIONS AND CONSTRUCTION WITH THE VHA COR AND THE
VHA INFECTION CONTROL OFFICER. ICRA CLASSIFICATIONS IN PHASING
SCHEDULE ARE FOR INITIAL REFERENCE ONLY. COMPLETE ICRA PERMIT
FOR EACH WORK AREA IN CONSULTATION WITH THE VHA FOR OFFICIAL
CLASSIFICATIONS PRIOR TO START OF WORK.
I. NO WORK SHALL OCCUR DURING THE TWO WEEKS PER YEAR DURING A
JCAHO INSPECTION.
J. PROVIDE SMOKE TIGHT SEPARATION BETWEEN ACTIVE PHASING ZONES
AND ADJACENT OCCUPIED AREAS. VERIFY INTEGRITY OF EXISTING
SMOKE PARTITIONS. PROVIDE TEMPORARY CONSTRUCTION PARTITIONS
TO MAINTAIN SMOKE SEPARATION WHERE EXISTING SEPARATIONS IS
COMPROMISED OR NON-EXISTING, IN ACCORDANCE WITH
SPECIFICATIONS. ADDITIONALLY PROVIDE 1-HR FIRE PROTECTION IF
SPRINKLERS ARE TO BE IMPAIRED IN THE AREA OF WORK.
LOADING
DOCK /
CORRIDOR
2A3
FOOD
SERVICE
KITCHEN
2A04
BREAK RM
2A07
INGREDIENT
STORAGE
2A09
OFFICE
2A10
VOLUNTEER
LOUNGE &
VOLUN…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .