This is an Addendum document issued by Whittington Architects Inc. for Grambling State University's reroofing project of Carver Hall Annex located in Grambling, Louisiana (Project No. 01-107-24-05, F.01004636). The project encompasses selective demolition, removal of deteriorated materials, installation of roofing insulation, SBS modified bitumen roofing system, sheet metal flashing and trim, and related work. Three unit-price line items are included: additional interply roofing membrane (500 square feet), replacement of deteriorated wood nailers and blocking (100 linear feet), and extension of vent pipes (8 each). Electronic bids are due July 2, 2026 at 2:00 PM Central Standard Time with public bid opening via Zoom at 2:05 PM CST. Site visits are encouraged and should be coordinated with Facilities Management or the Purchasing Department at 318-274-3238. Contract completion must occur within 120 consecutive calendar days from Notice to Proceed. Addendum No. 1, issued June 26, 2026, specifies that the project is tax-exempt, requires submission of a Unit Price Form with bids, mandates a new curb for mechanical equipment, requires existing gutters and downspouts to remain with new coping matching existing specifications, and designates U.S. PLY as the state-approved manufacturer with specific Duraflex SBS modified bitumen roofing materials detailed by ply type, thickness, weight, and composition.
Pricing must be quoted on a firm, net, F.O.B. Grambling State University Destination basis, inclusive of all labor, materials, equipment, tools, permits, taxes, shipping, and related costs. A bid bond equal to five percent of the total bid amount is required, transitioning to a performance bond of 50 percent of contract price upon award. Payment terms are Net 30 following receipt and approval of properly executed invoices on a 90/10 schedule, with ten percent retained until the contractor provides a clear lien certificate from the Lincoln Parish Clerk of Court. Liquidated damages are assessed at $300 per day for delays beyond the completion date. The contractor must be licensed under Louisiana Act 377 and maintain Workers Compensation insurance, Commercial General Liability at $1,000,000 minimum per occurrence, and Automobile Liability at $1,000,000 combined single limit, with Grambling State University named as additional insured. The contractor must record the contract with the Lincoln Parish Clerk of Court and provide proof of filing. The project is exempt from Louisiana state and local sales and use taxes, and the initial contract period does not exceed 12 months unless renewal terms are specified.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 50018-260030.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
(SECOND REBID) REROOFING OF BUILDING CARVER HALL ANNEX
GRAMBLING STATE UNIVERSITY
GRAMBLING, LA.
PROJECT NO. 01-107-24-05, F.01004636
WHITTINGTON ARCHITECTS INC
P.O. BOX 1701
RUSTON, LA. 71273-1701
318-548-2485
CONTACT: WOODY WHITTINGTON
318-548-2485
The following Addenda shall be included in the Contract as part of the Work together with the drawings and specifications for the above project. Include related changes throughout the various drawings and all sections of the specifications which should result from the changes listed.
GENERAL CONTRACTORS ARE ADVISED TO NOTIFY ALL AFFECTED
SUBCONTRACTORS, SUPPLIERS, ETC.; OF CHANGES INVOLVED IN THE
FOLLOWING ADDENDA INASMUCH AS THIS OFFICE DOES NOT HAVE A
COMPLETE RECORD OF ALL SUBCONTRACTORS, SUPPLIERS, ETC., FIGURING
THIS WORK.
ADDENDUM NO. 1
June 26, 2026
ITEM NO. 1: Project is TAX EXEMPT. Tax Exemption form is attached to this addendum for informational purposes; contractor is required to apply online.
ITEM NO. 2: UNIT PRICE FORM is attached to this addendum and shall be submitted with the contractors’ bid.
ITEM NO. 3: Provide new curb for mechanical equipment that is setting on a treated 4x4.
See photo attached to this addendum for location.
ITEM NO. 4: Existing gutters and downspouts to remain. New coping shall be provided where existing on lower roofs and expansion joints. Match existing in style, color and as detailed.
ITEM NO. 5: U.S. PLY is a state approved manufacturer.
Field Plies:
Cap Sheet: Duraflex 190FR SBS (170 mils/4.3 mm thick; weight 105 lbs per square; with a non-woven polyester mat).
Interply: Duraflex 190S SBS (120 mils/3.0 mm thick; weight 88 lbs per square;
with a non-woven polyester mat).
Granular Flashing Plies:
Cap Ply: Duraflex 190FR SBS (170 mils/4.3 mm thick; weight 105 lbs. per square; with a non-woven polyester mat).
Stripping Ply: Duraflex 190S SBS (120 mils/3.0 mm thick; weight 88 lbs. per square; with a non-woven polyester mat).
Heat Fused Granular Flashing Plies:
TBD
Heat Fused Aluminum Clad Flashing Plies:
Cap Ply: Duraflex Aluminum SBS (140 mils/3.5 mm thick; weight 103 lbs per square; with a fiberglass mat).
Stripping Ply: Duraflex 190S SBS (120 mils/3.0 mm thick; weight 88 lbs. per square; with a non-woven polyester mat) hot mopped.
Cold Adhesive: 901 Premium Modified Adhesive
ITEM NO. 6: The attached set of drawings shall be utilized for this project.
END OF ADDENDUM NO. 1
LOUISIANA UNIFORM PUBLIC WORK BID FORM
UNIT PRICE FORM
TO: GRAMBLING STATE UNIVERSITY BID FOR: REROOFING OF BUILDING
PURCHASING DEPARTMENT CARVER HALL ANNEX
GRAMBLING STATE UNIVERSITY
403 MAIN STREET GRAMBLING, LA.
GRAMBLING, LA. 71245
Project No.: 01-107-24-05, F.01004636
UNIT PRICES: This form shall be used for any and all work required by the Bidding Documents and described as unit prices. Amounts shall be stated in figures and only in figures.
DESCRIPTION: Base Bid or Alt.# ___Additional interply roofing membrane to eliminate ponding at interply
REF. NO. QUANTITY: UNIT OF MEASURE: UNIT PRICE UNIT PRICE EXTENSION (Quantity times Unit Price)
1 500 SQUARE FEET
DESCRIPTION: Base Bid or Alt.# ___Replace deteriorated wood nailers, blocking and installation of new wood nailers, blocking.
REF. NO. QUANTITY: UNIT OF MEASURE: UNIT PRICE UNIT PRICE EXTENSION (Quantity times Unit Price)
2 100 LINEAR FEET
DESCRIPTION: Base Bid or Alt.# ___Extend vent pipes above roof to accommodate new insulation depth.
REF. NO. QUANTITY: UNIT OF MEASURE: UNIT PRICE UNIT PRICE EXTENSION (Quantity times Unit Price)
3 8 Each
DESCRIPTION: Base Bid or Alt.# ___ REF. NO. QUANTITY: UNIT OF MEASURE: UNIT PRICE UNIT PRICE EXTENSION (Quantity times Unit Price)
NOT APPLICABLE NOT
APPLICABLE NOT APPLICABLE NOT APPLICABLE NOT APPLICABLE
DESCRIPTION: Base Bid or Alt.# Not applicable REF. NO. QUANTITY: UNIT OF MEASURE: UNIT PRICE UNIT PRICE EXTENSION (Quantity times Unit Price)
Not applicable Not applicable Not applicable Not applicable Not applicable
DESCRIPTION: Base Bid or Alt.# Not applicable REF. NO. QUANTITY: UNIT OF MEASURE: UNIT PRICE UNIT PRICE EXTENSION (Quantity times Unit Price)
Not applicable Not applicable Not applicable Not applicable Not applicable
DESCRIPTION: Base Bid or Alt.# Not applicable REF. NO. QUANTITY: UNIT OF MEASURE: UNIT PRICE UNIT PRICE EXTENSION (Quantity times Unit Price)
Not applicable Not applicable Not applicable Not applicable Not applicable
DESCRIPTION: Base Bid or Alt.# Not applicable REF. NO. QUANTITY: UNIT OF MEASURE: UNIT PRICE UNIT PRICE EXTENSION (Quantity times Unit Price)
Not applicable Not applicable Not applicable Not applicable Not applicable
Johnson Street, Grambling, Louisiana
State Project No. 01-107-25-05, Part No: F.01004636
REROOFING
Governor: Jeffrey M Landry
Commissioner of Administration: Taylor Barras
Office of Facility Planning and Control: Matthew Baker, Director
State of Louisiana
Site Code: 7-31-003
State ID: S07898
GRAMBLING STATE UNIVERSITY
SCHEDULE OF DRAWINGSVICINITY MAP
BID PHASE
SET NO.
SHEET NO.
R E
R O
O F
R E
-C O
V E
R
G R
A M
B L
IN
G
L O
U
IS
IA
N
A G
R A
M B
L
IN
G S
T A
T E
U N
IV
E
R S
IT
Y
M E
M B
E R
A M
E R
IC
A
N
IN
S T
IT
U
T E
O F
A R
C H
IT
E
C T
S
W H
IT
T
IN
G
T O
N A
R C
H
IT
E C
T S
, I N
C em ai l -w oo dy w hi tt@ ao l.c om
P H
O N
E
8)
-2
E . W
O O
D R
O W
W H
IT
T
IN
G
T O
N , J
R . A
R C
H
IT
E C
T
P .O
. B O
X
R
U S
T O
N , L
O U
IS
IA
N A
S ta te P ro je c t
N o
-1
-2
-0
P a rt
N o F
.0
G o v e rn o r:
J
J e ff re y M
L a n d ry o m m is s io n e r o f
A d m in is tr a ti o n
T a y lo r B a rr a s
D ir o f
F a c ili ty P la n n in g a n d
C o n tr l:
g e r
E H u s s e r
J r.
D ir e c to r
T-1
OF SHEETS1 5
/1
4/
VENT
LADDER
VENT
VENT
EXHAUST
VENT
EXHAUST
VENT
HATCH
VENT
VENT
VENT
VENT
ROOF TOP
EQUIPMENT
AREA DIVIDER
WALL
VENTVENT
VENT
VENT
CAPPED
ROOF CURB
CAPPED
ROOF CURB
EXHAUST
VENT
EXHAUST
VENT
VENT
CAPPED
ROOF CURB
VENT
CAPPED
ROOF CURB
CAPPED
ROOF
CURB
VENT
VENT
/8
/8
/8
/8
EXISTING
PRECAST FACIA
PANEL
GUTTER
0' - 0"
0' - 0"
0' - 0"
0' - 0"
-1' - 5"
-1' - 4 1/2"
-1' - 5"
-1' - 6 1/2"
-1' - 2"
-1' - 5"
-1' - 6"
-1' - 3"
-1' - 4 1/2"
-0' - 5"
-1' - 5 1/2"
-1' - 1 1/2"
-1' - 4"
-1' - 6 1/2"
-1' - 3 1/2"
-1' - 6"
-1' - 7"
-1' - 7"
-1' - 7"
-0' - 7 1/2"
-0' - 7 1/2"
-0' - 7 1/2"
-0' - 7 1/2"
-0' - 7 1/2" -0' - 7 1/2"
-0' - 6"
-1' - 6" -1' - 6"
-1' - 1"
-1' - 1 1/2"
-1' - 5"
-1' - 5"
CAPPED
ROOF
CURB
207'-0"
/2
101'-9" 9 1/2" 104'-6"
EDGE OF
ROOF2
A-3
A-4
A-4
A-4
NO WORK THIS
SHADED AREA
EXISTING
GUTTER
EXISTING
GUTTER
VENT
SCUPPER
/4
A-4
A-4
SCUPPER
SET NO.
SHEET NO.
M E
M B
E R
A M
E R
IC
A
N
IN
S T
IT
U
T E
O F
A R
C H
IT
E
C T
S
W H
IT
T
IN
G
T O
N A
R C
H
IT
E C
T S
, I N
C em ai l -w oo dy w hi tt@ ao l.c om
P H
O N
E
8)
-2
E . W
O O
D R
O W
W H
IT
T
IN
G
T O
N , J
R . A
R C
H
IT
E
. B O
X
R
U S
T O
N , L
O U
IS
IA
N A
A-1
OF SHEETS2 5
R E
R O
E
-C O
V E
R
G R
A M
B L
IN
G
L O
U
IS
IA
N
A G
R A
M B
L
IN
G S
T A
T E
U N
IV
E
R S
IT
Y
G o v e rn o r:
J
J e ff re y M
L a n m m is s io n e r o f
A d m in is tr a ti o n
T a y lo r B a rr a s
D ir o f
F a c ili ty P la n n in g a n d
C o n tr g e r
E H u s s e r
J r.
D ir e c to r
S ta te P ro je c t
N o
-1
-2
-0
P a rt
N o F
.0
/1
4/
/8
/8
/8
/8
0' - 0"
0' - 0"
0' - 0"
0' - 0"
-1' - 5"
-1' - 4 1/2"
-1' - 5"
-1' - 6 1/2"
-1' - 2"
-1' - 5"
-1' - 6"
-1' - 3"
-1' - 4 1/2"
-0' - 5"
-1' - 5 1/2"
-1' - 1 1/2"
-1' - 4"
-1' - 6 1/2"
-1' - 3 1/2"
-1' - 6"
-1' - 7"
-1' - 7"
-1' - 7"
-0' - 7 1/2"
-0' - 7 1/2"
-0' - 7 1/2"
-0' - 7 1/2"
-0' - 7 1/2" -0' - 7 1/2"
-0' - 6"
-1' - 6" -1' - 6"
-1' - 1"
-1' - 1 1/2"
-1' - 5"
-1' - 5"
A-3
A-4
A-4
A-4
SCUPPER
1 4
4"/12"
/4
1 4
4"/12"
1 4
EXSTING GUTTERS TO REMAIN
4"/12"
NEW MODIFIED BITUMEN ROOFING
OVER 12" COVERBOARD OVER 14" PER
FOOT TAPERED INSULATION OVER
MINIMUM 1 12" INSULATION OVER
REVERSED TAPER FIRST LAYER AT 14"
SLOPE TO "LEVEL OUT" THE EXISTING
DECK CONDITION OVER LIGHT WEIGHT
CONCRETE.
1 4
" INDICATES CRICKETS
INDICATES CRICKETS
A-4
A-4
SCUPPER
STANDING SEAM
COPING SEE DETAIL 3/A-4
SET NO.
SHEET NO.
M E
M B
E R
A M
E R
IC
A
N
IN
S T
IT
U
T E
O F
A R
C H
IT
E
C T
S
W H
IT
T
IN
G
T O
N A
R C
H
IT
E C
T S
, I N
C em ai l -w oo dy w hi tt@ ao l.c om
P H
O N
E
8)
-2
E . W
O O
D R
O W
W H
IT
T
IN
G
T O
N , J
R . A
R C
H
IT
E
. B O
X
R
U S
T O
N , L
O U
IS
IA
N A
A-2
OF SHEETS3 5
R E
R O
E
-C O
V E
R
G R
A M
B L
IN
G
L O
U
IS
IA
N
A G
R A
M B
L
IN
G S
T A
T E
U N
IV
E
R S
IT
Y
G o v e rn o r:
J
J e ff re y M
L a n m m is s io n e r o f
A d m in is tr a ti o n
T a y lo r B a rr a s
D ir o f
F a c ili ty P la n n in g a n d
C o n tr g e r
E H u s s e r
J r.
D ir e c to r
S ta te P ro je c t
N o
-1
-2
-0
P a rt
N o F
.0
/1
4/
NOTES:
1. WOOD NAILERS MUST BE INSTALLED WITH STAINLESS STL #8 SCREW FASTENERS TO MEET APPLICABLE BUILDING
CODES (200 LBS PER LINEAR FOOT MIN IN ANY GIVEN DIRECTION). STAINLESS STL FASTENERS IN TWO ROWS, STAGGERED, 12" O.C. EACH ROW.
2. ALL SHEET METAL IS TO BE INSTALLED PER SMACNA GUIDELINES. COPING TRIM TO BE FASTENED TO WOOD
NAILER @ 8" O.C. MAX.
3. GRANULES MUST BE EMBEDDED WHEN THERMALLY FUSING GRANULE SURFACED CAP SHEET.
4. REFER TO SHEET A-2 FOR SUGGESTED ROOF TAPER PLAN FOR REQUIRED THICKNESS OF WOOD NAILERS AT
ROOF EDGE. CONTRACTOR TO PROVIDE MANUFACTURER'S SUGGESTED TAPER PLAN FOR APPROVAL IF TAPER
LAYOUT DIFFERS FROM THAT PROVIDED. CONTRACTOR IS TO COORDINATE ADDITIONAL WOOD NAILER & COPING
MATERIALS, AS REQUIRED, AND INCLUDE IN BID PRICING. CHANGE ORDERS AFTER BIDDING, FOR THIS PURPOSE, WILL NOT BE ACCEPTED.
NEW 1 1/2" INSULATION BOARD
3" MIN
3" MIN
3" MIN
BUILT-UP ROOF PLY SYSTEM
MODIFIED BITUMEN GRANULE
SURFACED CAP SHEET
INTERPLY MEMBRANE
DRIP EDGE SET IN MULTI-PURPOSE MB
FLASHING CEMENT; PRIME FLANGE
BEFORE STRIPPING
INSTALL NEW PRESSURE TREATED NAILER TO
EXISTING EDGE FRAMING AS REQUIRED TO
MEET NEW ROOFING INSULATION THICKNESS.
EXISTING GUTTER TO REMAIN
NEW 1/4" TAPERED INSULATION
1/2" COVER BOARD
EXISTING 2 1/2" SLOPE OF
LIGHTWEIGHT CONCRETE
EXISTING DOUBLE "TEES"
EXISTING BLOCKING VERIFY
0' -4
1 2" V
E R
IF
Y
0' -0
1 2"
0' -7
0' -1
0" E
X
IS
T
IN
G , V
E R
IF
Y
PLUMBING VENT WITH LIQUID FLASHING
NOTES:
1. HOT WORK: THE CONTRACTOR IS RESPONSIBLE FOR DETERMINING APPROPRIATE CONDITIONS
CODES AND BUILDING OWNER'S REQUIREMENTS FOR HOT WORK OPERATIONS.
2. PRIMER: WHERE NOT SHOWN OR INDICATED ON DETAIL DRAWINGS, REFER TO MATERIAL PRODUCT
3. INSTALL PER MANUFACTURERS RECOMMENDED VERTICAL FLASHING HEIGHTS. FLASHING DETAILS
MANUFACTURER FOR ADDITIONAL REQUIREMENTS.
4. DO NOT APPLY LIQUID APPLIED SIYSTEMS OVER SBS MODIFIED BITUMEN MATERIALS
HOT AIR WELD OR TORCH APPLY THE SBS MODIFIED BITUMEN MEMBRANE AND FLASHINGS.
CLEAN AND PREPARE PENETRATION SURFACE
1/2" COVERBOARD
BASE SHEET/ANCHOR SHEET
DECKING
CAP SHEET
BASE PLY
POLYESTER REINFORCED
FLASHING BASE PLY
REINFORCING FABRIC
EXTEND REINFORCING FABRIC A MINIMUM
OF 4" BEYOND THE ROOF SURFACE
EXTEND REINFORCING FABRIC A MINIMUM
OF 8" BEYOND THE PENETRATION
OF 1/4" BEYOND REINFORCING FABRIC
EXTEND CAP FLASHING A MAXIMUM
OF 1" BEYOND REINFORCING FABRIC
LIQUID FLASHING
INSTALL FASTENER PLATE
AROUND PENETRATION SPACED
A MAXIMUM OF 12" APART
EXTEND FLASHING BASE PLY
A MINIMUM OF 3" BEYOND
FASTENER PLATES
EXTEND FLASHING A MINIMUM
EXTEND REINFORCING FABRIC FINGERS A MINIMUM
OF 2" BEYOND THE PENETRATION
TAPERED INSULATION
INSULATION
STRUCTURAL
TO UTILIZE HEAT-WELDING EQUIPMENT. REFER TO THE NRCA CERTA RECOMMENDATIONS, LOCAL
DATA SHEETS FOR PRIMER APPLICATION REQUIREMENTS.
SHOWN INCLUDE MINIMUM DIMENSIONS TO MEET WARRANTY REQUIREMENTS. CONTACT
ADHERED USING COLPLY OR COLPLY MODIFIED ADHESIVES OR CEMENTS. SELF ADHERE,
SET NO.
SHEET NO.
M E
M B
E R
A M
E R
IC
A
N
IN
S T
IT
U
T E
O F
A R
C H
IT
E
C T
S
W H
IT
T
IN
G
T O
N A
R C
H
IT
E C
T S
, I N
C em ai l -w oo dy w hi tt@ ao l.c om
P H
O N
E
8)
-2
E . W
O O
D R
O W
W H
IT
T
IN
G
T O
N , J
R . A
R C
H
IT
E
. B O
X
R
U S
T O
N , L
O U
IS
IA
N A
A-3
OF SHEETS4 5
R E
R O
E
-C O
V E
R
G R
A M
B L
IN
G
L O
U
IS
IA
N
A G
R A
M B
L
IN
G S
T A
T E
U N
IV
E
R S
IT
Y
G o v e rn o r:
J
J e ff re y M
L a n m m is s io n e r o f
A d m in is tr a ti o n
T a y lo r B a rr a s
D ir o f
F a c ili ty P la n n in g a n d
C o n tr g e r
E H u s s e r
J r.
D ir e c to r
S ta te P ro je c t
N o
-1
-2
-0
P a rt
N o F
.0
/1
4/
SET NO.
SHEET NO.
M E
M B
E R
A M
E R
IC
A
N
IN
S T
IT
U
T E
O F
A R
C H
IT
E
C T
S
W H
IT
T
IN
G
T O
N A
R C
H
IT
E C
T S
, I N
C em ai l -w oo dy w hi tt@ ao l.c om
P H
O N
E
8)
-2
E . W
O O
D R
O W
W H
IT
T
IN
G
T O
N , J
R . A
R C
H
IT
E
. B O
X
R
U S
T O
N , L
O U
IS
IA
N A
A-4
OF SHEETS5 5
R E
R O
E
-C O
V E
R
G R
A M
B L
IN
G
L O
U
IS
IA
N
A G
R A
M B
L
IN
G S
T A
T E
U N
IV
E
R S
IT
Y
G o v e rn o r:
J
J e ff re y M
L a n m m is s io n e r o f
A d m in is tr a ti o n
T a y lo r B a rr a s
D ir o f
F a c ili ty P la n n in g a n d
C o n tr g e r
E H u s s e r
J r.
D ir e c to r
/1
4/
S ta te P ro je c t
N o
-1
-2
-0
P a rt
N o F
.0
File details come from the government source that posted it. Updated .