5-4-CS26098-27042240-Hazmat Survey.pdf
PDF 4 MB Posted
- Solicitation number
- CS26098
- Issued by
- Utah
About this file
This Hazardous Materials Survey document is prepared for the State of Utah Division of Facilities Construction and Management (DFCM) in support of a roofing replacement project at Ogden-Weber Technical College (Project #27042240). The survey identifies and assesses hazardous materials present at the facility, specifically related to the planned Built-Up Roofing (BUR) to single-ply membrane replacement project with an estimated construction cost of $1,000,000. The survey provides a comprehensive baseline of existing conditions and potential hazardous materials that must be addressed during the demolition and replacement phases of the roofing work.
The hazardous materials assessment is a critical supporting document for prequalified contractors bidding on this Stage II Invitation to Bid. Only contractors who have completed Stage I prequalification and appear on the current DFCM Prequalified Contractors list are eligible to submit bids. The survey findings inform the scope of work, cost estimates, and safety protocols required for the project, ensuring that bidders have complete information regarding any hazardous materials removal, abatement, or handling procedures that must be incorporated into their bids and project execution plans.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
A LIMITED ASBESTOS
INSPECTION, SURVEY AND ASSESSMENT
FOR THE ROOF OF THE
OGDEN WEBER TECH CONSTRUCTION TRADES
200 NORTH WASHINGTON BLVD
OGDEN, UTAH 84404
March 23, 2025
Prepared for:
Mrs. Aubrey Stapel
Project Manager
State of Utah
Department of Administrative Services
Division of Facilities Construction and Management (DFCM)
State Office Building Room 4110
Salt Lake City, Utah 84114
PH: (801) 641-0964
Prepared by:
R & R Environmental, Inc. (R & R)
47 West 9000 South, Suite #2
Sandy, Utah 84070 dave@rrenviro.com
Phone (801) 541-1035
Table of Contents
ASBESTOS
1.0 INTRODUCTION
2.0 EXECUTIVE SUMMARY
3.0 SAMPLING METHODS
4.0 SURVEY RESULTS
5.0 CONCLUSIONS
6.0 LIMITATIONS AND EXCLUSION OF WARRANTY.……………………………………………………8
List of Appendices
Appendix A Sample Log
Appendix B Laboratory Report
Appendix C Photo Log
Appendix D Certifications
Limited Asbestos Survey Report Page 1 Ogden Weber tech Construction Trades
1.0 INTRODUCTION
R & R Environmental, Inc. (R & R) was contacted to conduct a limited asbestos survey for the Ogden Weber tech
Construction Trades located at 200 North Washington Blvd in Ogden, Utah. The survey consisted of a visual assessment of the exterior of building for suspect asbestos containing materials (ACM) and bulk sampling of the materials. The fieldwork component of this survey was conducted by Mr. George Latu who is a Utah Accredited
Asbestos Building Inspector.
This report presents the conditions and observations noted on the visit dates.
The following general information is included in this survey report:
• Executive Summary (Section 2.0)
• Sampling Methods (Section 3.0)
• Analytical Results (Section 4.0)
• Conclusions (5.0)
Limited Asbestos Survey Report Page 2
2.0 EXECUTIVE SUMMARY
No asbestos containing materials were identified in the affected area of the building.
Limited Asbestos Survey Report Page 3
OGDEN WEBER TECH CONSTRUCTION TRADES
OGDEN, UTAH 84404
DATE OF SURVEY: FEBRAURY 28, 2025
NESHAP - REGULATED
ASBESTOS-CONTAINING MATERIALS (R-ACM)
1. Friable asbestos material (>1% asbestos and can be crumbled, pulverized or reduced to powder by hand pressure)
Thermal system insulation (TSI)*
Textured ceiling material (TCM)*
Spray-on insulation or fireproofing*
Blown-in insulation*
Ceiling tiles/panels*
Plaster, gypsum board, gypsum board joint compound*
Cloth materials* (Boiler Flue Gasket)
Paper materials* (HVAC Paper Tape and Insulating Board)
Electrical wiring insulation*
Sink undercoating (loose)*
Other*
2. Category I ACM which has become friable
Packings
Gaskets
Resilient floor coverings (floor tile and sheet vinyl)
Asphalt roofing products (Dust Debris, Roofing Underlayment Debris, Flashing Material)
3. Category I ACM that will be or has been subjected to sanding, grinding, cutting or abrading
Packings
Gaskets
Resilient floor coverings (floor tile and sheet vinyl)
Asphalt roofing products
4. Category II ACM that has a high probability of becoming or has become friable in the course of demolition or renovation operations
Asbestos cement materials (transite)*
Asphalt, tar and rubber-base ACM products other than roofing products*
Non-asphalt and non-paper roofing products*
Paint*
Fire brick and/or mortar*
Stainless steel sink undercoating (solid)*
Encapsulated TCM*
Encapsulated TSI*
Mastic for floor tile, ceiling tile, cove molding, etc.*
Other
Limited Asbestos Survey Report Page 4
DATE OF SURVEY: FEBRAURY 28, 2025
NESHAP NON-REGULATED
ASBESTOS-CONTAINING MATERIAL (N-R-ACM)
1. > 1% asbestos
2. Category I Non-friable (cannot be crumbled, pulverized, or reduced to powder by hand pressure) ACM with >1% asbestos by new PLM procedure
Packings
_ Gaskets (Door/Window Caulking)
Resilient floor coverings (floor tile)
_Asphalt roofing products
3. Category II Non-friable ACM with >1% asbestos by new PLM procedure (Category includes items meeting Category I definition but not specifically listed in that category)
Asbestos cement materials (transite)* (Fume hoods, counter tops, and window panels)
Asphalt, tar and rubber-base ACM products other than roofing products*
Non-asphalt and non-paper roofing products*
Paint* (Silver Paint Sealant)
Fire brick and/or mortar*
Sink undercoating (solid)*
Mastic for floor tile, ceiling tile, cove molding, etc.*
Other* (Window Glaze)
Notes:
1. (*) denotes R & R’s interpretation of materials included in this category.
2. New PLM procedure is outlined in Appendix A, Subpart F, 40 CFR, Part 783, Section 1, Polarized Light
Microscopy.
3. The Environmental Protection Agency (EPA) National Emission Standard for Hazardous Air Pollutants
(NESHAP) asbestos revision as outlined in 40 CFR, Part 61, became effective November 20, 1990. The asbestos classification system outlined in the revision and included in this section is dynamic in nature.
Asbestos materials classified as “NON-REGULATED” at the time of the survey may become
“REGULATED” due to ongoing or planned maintenance, renovation, or demolition actions, which can transform a material containing greater than 1% asbestos from a “non-friable” and NON-REGULATED to a friable and REGULATED condition. Classification of ACM in this section and in the executive summary of this report is, therefore, based on the observations of the surveyor at the time of the survey and may or may not be appropriate at later dates.
4. Maintenance, renovation, demolition, weathering, normal wear, water or other damage can alter the “NON-
REGULATED” status of materials, and necessitate precautions required for handling them as
“REGULATED” asbestos-materials.
Limited Asbestos Survey Report Page 5
3.0 SAMPLING METHODS
Survey procedures were based on those outlined in Title 40 Code of Federal Regulation (CFR) Part 763, USEPA
Asbestos Hazard Emergency Response Act, and the Asbestos Model Accreditation Plan (effective April 4, 1994). The procedures included visual observation, physical inspection, bulk sample collection, and condition assessment of suspect ACM. The number of samples collected was based on the amount and accessibility of each homogeneous material, with consideration given for the type, age, and condition.
Eighteen (18) samples were collected from the suspect materials to assess the presence of asbestos (or lack thereof) in building materials/systems. Each sample collected was placed into a sealable plastic bag or tub, marked with a unique sample identification code, and packaged for subsequent shipment to the laboratory for analysis. Individual sample identification consisted of a numeric code denoting the sampling media/location.
Subsequent to packaging and labeling, samples were submitted under proper chain-of-custody to Reservoirs
Environmental, Inc., Denver, Colorado. The National Voluntary Laboratory Accreditation Program (NVLAP), Lab
Code 101896 accredits Reservoirs for asbestos analysis. Samples were analyzed via Polarized Light Microscopy
(PLM) utilizing EPA Method 600/M4-82-020. Please note that USEPA and OSHA regulations define an ACM as a material containing more than one (1) percent asbestos, by volume, as determined by PLM analysis. In the case of multi-layer systems (e.g., floor tile/mastic layers), the laboratory analyzed and reported each layer separately.
4.0 SURVEY RESULTS
Eighteen (18) representative samples collected were submitted for analytical determination. A summary of analytical results for samples collected and analyzed for this survey are in Appendix B (Laboratory Results) and are discussed below by building material/system type. Photographs of the buildings where samples were taken are included as
Appendix C. Floor Plans of the building where samples were taken are included in Appendix D
Limited Asbestos Survey Report Page 6
5.0 CONCLUSIONS
Asbestos-containing materials were not identified in the building. See executive summary for details.
6.0 LIMITATIONS AND EXCLUSION OF WARRANTY
This limited asbestos survey and assessment was performed using procedures and a level of diligence typically exercised by professional consultants performing similar services. However, asbestos-containing material
(ACM) can be present in a structure but not identified using ordinary investigative procedures.
No asbestos survey can completely, eliminate uncertainty regarding the presence of ACM. R & R
Environmental, Inc.’s level of diligence and investigative procedures are intended to reduce, but not eliminate, potential uncertainty regarding the presence of ACM. The procedures used for this survey attempt to establish a balance between the competing goals of limiting investigative costs, time, and building damage, and reducing the uncertainty about unknown conditions. Therefore, the determinations in this report should not be construed as a guarantee that all ACM present in the subject property has been included in this report.
This report presents R & R Environmental, Inc.’s professional determinations, which are dependent upon information obtained during performance of consulting services. R & R Environmental, Inc. assumes no responsibility for omissions or errors resulting from inaccurate information provided by sources outside of R &
R Environmental, Inc.
No warranty or guarantee, expressed or implied, is made regarding the findings, conclusions, or recommendations contained in this report. The limitations presented above supersede the requirements or provisions of all other contracts or scopes of work, implied, or otherwise, except stated or acknowledged herein.
Limited Asbestos Survey Report Page 7
A LIMITED ASBESTOS SURVEY AND ASSESSMENT
OF THE
OGDEN WEBER TECH CONSTRUCTION TRADES
OGDEN, UTAH 84404
On February 28, 2025, R & R Environmental, Inc. (R & R) of Sandy, Utah, conducted a limited asbestos survey and assessment of the Ogden Weber tech Construction Trades located at 200 North Washington Blvd in Ogden, Utah.
Bulk samples of suspect asbestos-containing materials were collected and analyzed. The condition of all friable and non-friable asbestos-containing materials was, assessed. The following accredited inspector conducted the survey and assessment.
Inspected by:
March 23, 2025
George Latu Date
State of Utah, Division of Air Quality Inspector
Certification Number: ASB-7670
State of Utah Company Certification: ASBC-237
This report was reviewed by:
March 23, 2025
David C. Roskelley, MSPH, CIH, CSP Date
State of Utah, Division of Air Quality Inspector
Certification Number: ASB-1370
AHERA Inspector #5 PSI 65451 I
Certified Safety Professional #15774
Certified Industrial Hygienist #8529
State of Utah Company Certification: ASBC-237
Appendix A
Sample Log
SAMPLE LOG
Sample #
Material/
Homogenous Area
Sample Location
Quantity
Lab Result
(%/Type)
Assessment
CT-01 Roofing Roof 41,661 Ft2 None Detected Undamaged
CT-02 Roofing Roof 41,661 Ft2 None Detected Undamaged
CT-03 Roofing Roof 41,661 Ft2 None Detected Undamaged
CT-04 Roofing Roof 41,661 Ft2 None Detected Undamaged
CT-05 Roofing Roof 41,661 Ft2 None Detected Undamaged
CT-06 Roofing Roof 41,661 Ft2 None Detected Undamaged
CT-07 Roofing Roof 41,661 Ft2 None Detected Undamaged
CT-08 Roofing Roof 41,661 Ft2 None Detected Undamaged
CT-09 Roofing Roof 41,661 Ft2 None Detected Undamaged
CT-10 Silver Caulking Roof 150 Ft2 None Detected Undamaged
CT-11 Silver Caulking Roof 150 Ft2 None Detected Undamaged
CT-12 White Caulking Roof 320 Ft2 None Detected Undamaged
CT-13 White Caulking Roof 320 Ft2 None Detected Undamaged
CT-14 Black Roof Siding Roof 40 Ft2 None Detected Undamaged
CT-15 Black Roof Siding Roof 40 Ft2 None Detected Undamaged
CT-16 Wall System Workshop 2 30 Ft2 None Detected Undamaged
CT-17 Wall System Workshop 2 30 Ft2 None Detected Undamaged
CT-18 Wall System Workshop 2 30 Ft2 None Detected Undamaged
Appendix B
Laboratory Report
March 07, 2025
Sincerely, Jeanne Spencer President
Subcontractor Number:
Laboratory Report: RES 639862-1
Project #/P.O. #: None Given
Project Description: OGDEN WEBER TECH ROOF
George Latu R & R Environmental 47 West 9000 South #2 Sandy UT 84070
Dear George, Eurofins Reservoirs is an analytical laboratory accredited for the analysis of Industrial Hygiene and Environmental matrices by the National Voluntary Laboratory Accreditation Program (NVLAP), Lab Code 101896-0 for Transmission Electron Microscopy (TEM) and Polarized Light Microscopy (PLM) analysis and the American Industrial Hygiene Association (AIHA LAP, LLC), Lab ID 101533 for Phase Contrast Microscopy (PCM) analysis. This laboratory is currently proficient in both Proficiency Testing and PAT programs respectively.
Eurofins Reservoirs has analyzed the following samples for asbestos content as per your request. The analysis has been completed in general accordance with the appropriate methodology as stated in the attached analysis table. The results have been submitted to your office.
RES 639862-1 is the job number assigned to this study. This report is considered highly confidential and the sole property of the customer. Eurofins Reservoirs will not discuss any part of this study with personnel other than those of the client. The results described in this report only apply to the samples analyzed, as received and with the information provided by the customer. This report must not be used to claim endorsement of products or analytical results by NVLAP or any agency of the U.S. Government. This report shall not be reproduced except in full, without written approval from Eurofins Reservoirs. Samples will be disposed of after sixty days unless longer storage is requested. If you have any questions about this report, please feel free to call 303-964-1986.
by Paul LoScalzo
03/07/202503/07/202503/07/202503/07/2025
Eurofins Reservoirs Environmental, Inc Eurofins Reservoirs QA Manual
Effective September 06, 2023 Q:\QAQC\Eurofins Reservoirs QA Manual.pdf
(303) 964-1986
(866) RES-IENV
https://www.eurofinsus.com/builtenv https://clients.rei.et.eurofinsus.com
4955 Yarrow St, Suite 100, Arvada, CO 80002
Laboratory Sample IDLaboratory Sample IDLaboratory Sample IDLaboratory Sample ID LLLL Asbestos ContentAsbestos ContentAsbestos ContentAsbestos Content Non-Non-Non-Non- Non-Non-Non-Non- AAAA SubSubSubSub AsbestosAsbestosAsbestosAsbestos FibrousFibrousFibrousFibrous YYYY PhysicalPhysicalPhysicalPhysical PartPartPartPart MineralMineralMineralMineral VisualVisualVisualVisual FibrousFibrousFibrousFibrous ComponentsComponentsComponentsComponents EEEE DescriptionDescriptionDescriptionDescription EstimateEstimateEstimateEstimate ComponentsComponentsComponentsComponents
Client Sample NumberClient Sample NumberClient Sample NumberClient Sample Number RRRR (%) (%) (%) (%) 639862 -639862 -639862 -639862 - CT-01CT-01CT-01CT-01 A Yellow foam 5 NDNDNDND 0 100.0 B Brown fibrous perlitic material 25 NDNDNDND 80 20.0 C Black fibrous tar 35 NDNDNDND 15 85.0 D Black tar w/ brown rock 35 NDNDNDND 0 100.0 639862 -639862 -639862 -639862 - CT-02CT-02CT-02CT-02 A Black tar 20 NDNDNDND 0 100.0 B Brown fibrous perlitic material 30 NDNDNDND 80 20.0 C Black fibrous tar 50 NDNDNDND 20 80.0 639862 -639862 -639862 -639862 - CT-03CT-03CT-03CT-03 A Black tar 15 NDNDNDND 0 100.0 B Yellow foam w/ gray fibrous material 20 NDNDNDND 25 75.0 C Brown fibrous perlitic material 30 NDNDNDND 80 20.0 D Black fibrous tar 35 NDNDNDND 20 80.0 639862 -639862 -639862 -639862 - CT-04CT-04CT-04CT-04 A Yellow foam 5 NDNDNDND 0 100.0 B Black felt 15 NDNDNDND 50 50.0 C Brown fibrous perlitic material 20 NDNDNDND 60 40.0 D Black tar w/ black rock 25 NDNDNDND TR 100.0 E Black fibrous tar 35 NDNDNDND 20 80.0 TEM Analysis recommended for organically bound material (i.e. floor tile) if PLM results are <1%.
Eurofins Reservoirs Environmental, Inc Eurofins Reservoirs QA Manual
Effective September 06, 2023 Q:\QAQC\Eurofins Reservoirs QA Manual.pdf
RES Job Number:
Client:
Client Project/P.O.:
Client Project Description:
Date Samples Received:
Analysis Type:
Turnaround:
Date Samples Analyzed:
RES 639862-1
R & R Environmental None Given
OGDEN WEBER TECH ROOF
February 28, 2025 EPA 600/R-93/116 - Short Report, Bulk Priority March 06 - March 07, 2025
EUROFINS RESERVOIRS ENVIRONMENTAL, INC
NVLAP Lab Code 101896-0
AIHA LAP, LLC. LAB ID 101533
TABLE: I ANALYSIS: PLM BULK ANALYSIS, PERCENTAGE COMPOSITION BY VOLUME
NA = Not Analyzed NR = Not Received ND = None Detected TR = Trace; <1 % Visual Estimate Trem-Act = Tremolite-Actinolite
(303) 964-1986
(866) RES-IENV
https://www.eurofinsus.com/builtenv https://clients.rei.et.eurofinsus.com
Laboratory Sample IDLaboratory Sample IDLaboratory Sample IDLaboratory Sample ID LLLL Asbestos ContentAsbestos ContentAsbestos ContentAsbestos Content Non-Non-Non-Non- Non-Non-Non-Non-
YYYY PhysicalPhysicalPhysicalPhysical PartPartPartPart MineralMineralMineralMineral VisualVisualVisualVisual FibrousFibrousFibrousFibrous ComponentsComponentsComponentsComponents EEEE DescriptionDescriptionDescriptionDescription EstimateEstimateEstimateEstimate ComponentsComponentsComponentsComponents
Client Sample NumberClient Sample NumberClient Sample NumberClient Sample Number RRRR (%) (%) (%) (%) 639862 -639862 -639862 -639862 - CT-05CT-05CT-05CT-05 A Black tar 5 NDNDNDND 0 100.0 B Brown fibrous perlitic material 10 NDNDNDND 70 30.0 C Black fibrous tar 10 NDNDNDND 20 80.0 D Gray fibrous perlitic material 75 NDNDNDND 65 35.0 639862 -639862 -639862 -639862 - CT-06CT-06CT-06CT-06 A Yellow foam 10 NDNDNDND 0 100.0 B Black tar 20 NDNDNDND 0 100.0 C Brown fibrous perlitic material 30 NDNDNDND 65 35.0 D Black fibrous tar 40 NDNDNDND 25 75.0 639862 -639862 -639862 -639862 - CT-07CT-07CT-07CT-07 A Black tar 15 NDNDNDND 0 100.0 B Black fibrous tar 30 NDNDNDND 25 75.0 C Light-gray fibrous perlitic material 55 NDNDNDND 60 40.0 639862 -639862 -639862 -639862 - CT-08CT-08CT-08CT-08 A White foam 3 NDNDNDND 0 100.0 B Brown fibrous perlitic material 5 NDNDNDND 65 35.0 C Black tar w/ black rock 20 NDNDNDND 0 100.0 D Black fibrous tar 72 NDNDNDND 20 80.0 TEM Analysis recommended for organically bound material (i.e. floor tile) if PLM results are <1%.
Eurofins Reservoirs Environmental, Inc Eurofins Reservoirs QA Manual
Effective September 06, 2023 Q:\QAQC\Eurofins Reservoirs QA Manual.pdf
RES Job Number:
Client:
Client Project/P.O.:
Client Project Description:
Date Samples Received:
Analysis Type:
Turnaround:
Date Samples Analyzed:
RES 639862-1
R & R Environmental None Given
OGDEN WEBER TECH ROOF
February 28, 2025 EPA 600/R-93/116 - Short Report, Bulk Priority March 06 - March 07, 2025
EUROFINS RESERVOIRS ENVIRONMENTAL, INC
NVLAP Lab Code 101896-0
AIHA LAP, LLC. LAB ID 101533
TABLE: I ANALYSIS: PLM BULK ANALYSIS, PERCENTAGE COMPOSITION BY VOLUME
NA = Not Analyzed NR = Not Received ND = None Detected TR = Trace; <1 % Visual Estimate Trem-Act = Tremolite-Actinolite
(303) 964-1986
(866) RES-IENV
https://www.eurofinsus.com/builtenv https://clients.rei.et.eurofinsus.com
Laboratory Sample IDLaboratory Sample IDLaboratory Sample IDLaboratory Sample ID LLLL Asbestos ContentAsbestos ContentAsbestos ContentAsbestos Content Non-Non-Non-Non- Non-Non-Non-Non-
YYYY PhysicalPhysicalPhysicalPhysical PartPartPartPart MineralMineralMineralMineral VisualVisualVisualVisual FibrousFibrousFibrousFibrous ComponentsComponentsComponentsComponents EEEE DescriptionDescriptionDescriptionDescription EstimateEstimateEstimateEstimate ComponentsComponentsComponentsComponents
Client Sample NumberClient Sample NumberClient Sample NumberClient Sample Number RRRR (%) (%) (%) (%)
639862 -639862 -639862 -639862 - CT-09CT-09CT-09CT-09 A Black tar w/ light-gray rock 20 NDNDNDND TR 100.0 B Gray fibrous perlitic material 30 NDNDNDND 65 35.0 C Black fibrous tar 50 NDNDNDND 15 85.0 639862 -639862 -639862 -639862 - CT-10CT-10CT-10CT-10 A Gray resinous material 5 NDNDNDND 0 100.0 B White resinous material 95 NDNDNDND 0 100.0 639862 -639862 -639862 -639862 - CT-11CT-11CT-11CT-11 A Gray resinous material 1 NDNDNDND 0 100.0 B White resinous material 99 NDNDNDND 0 100.0 639862 -639862 -639862 -639862 - CT-12CT-12CT-12CT-12 A Black fibrous tar 7 NDNDNDND 10 90.0 B Silver paint w/ black rock 93 NDNDNDND 5 95.0 639862 -639862 -639862 -639862 - CT-13CT-13CT-13CT-13 A Gray cementitious material 1 NDNDNDND 0 100.0 B Black fibrous tar 7 NDNDNDND 10 90.0 C Silver fibrous paint w/ black rock 92 NDNDNDND 3 97.0 639862 -639862 -639862 -639862 - CT-14CT-14CT-14CT-14 A Silver paint TR NDNDNDND 8 92.0 B Black fibrous tar 100 NDNDNDND 25 75.0 639862 -639862 -639862 -639862 - CT-15CT-15CT-15CT-15 A Black fibrous tar 100 NDNDNDND 25 75.0 TEM Analysis recommended for organically bound material (i.e. floor tile) if PLM results are <1%.
Eurofins Reservoirs Environmental, Inc Eurofins Reservoirs QA Manual
Effective September 06, 2023 Q:\QAQC\Eurofins Reservoirs QA Manual.pdf
RES Job Number:
Client:
Client Project/P.O.:
Client Project Description:
Date Samples Received:
Analysis Type:
Turnaround:
Date Samples Analyzed:
RES 639862-1
R & R Environmental None Given
OGDEN WEBER TECH ROOF
February 28, 2025 EPA 600/R-93/116 - Short Report, Bulk Priority March 06 - March 07, 2025
EUROFINS RESERVOIRS ENVIRONMENTAL, INC
NVLAP Lab Code 101896-0
AIHA LAP, LLC. LAB ID 101533
TABLE: I ANALYSIS: PLM BULK ANALYSIS, PERCENTAGE COMPOSITION BY VOLUME
NA = Not Analyzed NR = Not Received ND = None Detected TR = Trace; <1 % Visual Estimate Trem-Act = Tremolite-Actinolite
(303) 964-1986
(866) RES-IENV
https://www.eurofinsus.com/builtenv https://clients.rei.et.eurofinsus.com
Laboratory Sample IDLaboratory Sample IDLaboratory Sample IDLaboratory Sample ID LLLL Asbestos ContentAsbestos ContentAsbestos ContentAsbestos Content Non-Non-Non-Non- Non-Non-Non-Non-
YYYY PhysicalPhysicalPhysicalPhysical PartPartPartPart MineralMineralMineralMineral VisualVisualVisualVisual FibrousFibrousFibrousFibrous ComponentsComponentsComponentsComponents EEEE DescriptionDescriptionDescriptionDescription EstimateEstimateEstimateEstimate ComponentsComponentsComponentsComponents
Client Sample NumberClient Sample NumberClient Sample NumberClient Sample Number RRRR (%) (%) (%) (%) 639862 -639862 -639862 -639862 - CT-16CT-16CT-16CT-16 A White tape 2 NDNDNDND 80 20.0 B White texture w/ white paint 3 NDNDNDND 0 100.0 C White joint compound 3 NDNDNDND 0 100.0 D White/tan drywall 92 NDNDNDND 15 85.0 639862 -639862 -639862 -639862 - CT-17CT-17CT-17CT-17 A White texture w/ white paint 1 NDNDNDND 2 98.0 B White tape 2 NDNDNDND 80 20.0 C White joint compound 3 NDNDNDND 0 100.0 D White/tan drywall 94 NDNDNDND 15 85.0 639862 -639862 -639862 -639862 - CT-18CT-18CT-18CT-18 A White joint compound 8 NDNDNDND 2 98.0 B White tape 12 NDNDNDND 80 20.0 C White texture w/ white paint 15 NDNDNDND 0 100.0 D White/tan drywall 65 NDNDNDND 5 95.0 TEM Analysis recommended for organically bound material (i.e. floor tile) if PLM results are <1%.
Mike Scales Analyst
Tyler Hutchinson Analyst
Eurofins Reservoirs Environmental, Inc Eurofins Reservoirs QA Manual
Effective September 06, 2023 Q:\QAQC\Eurofins Reservoirs QA Manual.pdf
RES Job Number:
Client:
Client Project/P.O.:
Client Project Description:
Date Samples Received:
Analysis Type:
Turnaround:
Date Samples Analyzed:
RES 639862-1
R & R Environmental None Given
OGDEN WEBER TECH ROOF
February 28, 2025 EPA 600/R-93/116 - Short Report, Bulk Priority March 06 - March 07, 2025
EUROFINS RESERVOIRS ENVIRONMENTAL, INC
NVLAP Lab Code 101896-0
AIHA LAP, LLC. LAB ID 101533
TABLE: I ANALYSIS: PLM BULK ANALYSIS, PERCENTAGE COMPOSITION BY VOLUME
NA = Not Analyzed NR = Not Received ND = None Detected TR = Trace; <1 % Visual Estimate Trem-Act = Tremolite-Actinolite
(303) 964-1986
(866) RES-IENV
https://www.eurofinsus.com/builtenv https://clients.rei.et.eurofinsus.com
SUBMITTED BY INVOICE TO
Client Sample ID Number
RES Job #: 639862
CONTACT INFORMATION SERIES
ASBESTOS LABORATORY REQUESTED ANALYSIS VALID MATRIX CODES LAB NOTES
CHEMISTRY LABORATORY
MICROBIOLOGY LABORATORY
**Turnaround times establish a laboratory priority, subject to laboratory volume and are not guaranteed. Additional fees apply for afterhours, weekends and holidays.**
Laboratory Analysis Instructions
(Sample ID's must be unique)
Company: R & R Environmental Company: R & R Environmental
Address: 47 West 9000 South #2 Address: 47 West 9000 South #2
Sandy, UT 84070 Sandy, UT 84070
Project Number and/or P.O. #: None Given Project Zip Code:
Project Description/Location: OGDEN WEBER TECH ROOF
Contact: George Latu -1 PLM Priority Phone: (801) 870-3590
Fax:
Cell: (801) 870-3590
Final Data Deliverable Email Address:
george@rrenviro.com (+ 24 ADDNL. CONTACTS)
PLM / PCM / TEM DTL RUSH PRIORITY STANDARD Air = A Bulk = B
Dust = D Food = F
Paint = P Soil = S
Dust RUSH PRIORITY STANDARD
*PRIOR NOTICE REQUIRED FOR SAME DAY TAT
Surface = SU Swab = SW
Tape = T Wipe = W
Metals RUSH PRIORITY STANDARD Drinking Water = DW
Waste Water = WW
Organics* SAME DAY RUSH PRIORITY STANDARD **ASTM E1792 approved wipe media only**
Viable Analysis** PRIORITY STANDARD
**TAT DEPENDENT ON SPEED OF MICROBIAL GROWTH
Medical Device Analysis RUSH STANDARD
Mold Analysis RUSH PRIORITY STANDARD
Special Instructions:
ASBESTOS CHEMISTRY MICROBIOLOGY ICO
1 CT-01 X B
2 CT-02 X B
3 CT-03 X B
4 CT-04 X B
5 CT-05 X B
6 CT-06 X B
7 CT-07 X B
8 CT-08 X B
9 CT-09 X B
10 CT-10 X B
11 CT-11 X B
12 CT-12 X B
13 CT-13 X B
P L
M
P L
M S h o rt R ep o rt (E
PA
/6
/R
-9 3/
6)
T E
M
P C
M
D U
S T
M E
TA
L
S
O R
G A
N
IC
S
V
IA
B L
E S
M E
D
IC
A L
M O
L D
S am pl e
V ol um e
(L
A re a
S am pl e
Te m pe ra tu re
C
Le ng th (o r A liq uo ts
) x W id th
(o r A re a/
A liq uo t)
M at rix C od e of
C on ta in er s
D at e C ol le ct ed m m
/d d/ yy
T im e C ol le ct ed hh :m m
Eurofins Reservoirs Environmental, Inc establishes a unique Lab Sample ID, for each sample, by preceding each unique Client Sample ID with the laboratory RES Job Number.
Eurofins Reservoirs Environmental, Inc will analyze incoming samples based on information received and will not be responsible for errors or omissions in calculations resulting from the inaccuracy of original data. By signing, client/company representative agrees that submission of the following samples for requested analysis as indicated on this Chain of Custody shall consitute an analytical services agreement with payment terms of NET 30 days. Failure to comply with payment terms may result in a 1.5% monthly interest surcharge.
Relinquished By:
George Latu Date/Time: 02/27/2025 10:03:58 Sample Condition: Acceptable
Received By:
Emily Creasey Date/Time: 02/28/2025 10:37:09 Carrier: Fed-Ex
Eurofins Reservoirs Environmental, Inc Eurofins Reservoirs QA Manual
Effective September 06, 2023 Q:\QAQC\Eurofins Reservoirs QA Manual.pdf
(303) 964-1986
(866) RES-IENV
https://www.eurofinsus.com/builtenv https://clients.rei.et.eurofinsus.com
Client Sample ID Number
REQUESTED ANALYSIS VALID MATRIX CODES LAB NOTES
Laboratory Analysis Instructions
(Sample ID's must be unique)
Air = A Bulk = B
Dust = D Food = F
Paint = P Soil = S
Surface = SU Swab = SW
Tape = T Wipe = W
Drinking Water = DW
Waste Water = WW
**ASTM E1792 approved wipe media only**
RES Job #: 639862
Submitted By: R & R Environmental
ASBESTOS CHEMISTRY MICROBIOLOGY ICO
14 CT-14 X B
15 CT-15 X B
16 CT-16 X B
17 CT-17 X B
18 CT-18 X B
P L
M
P L
M S h o rt R ep o rt (E
PA
/6
/R
-9 3/
6)
T E
M
P C
M
D U
S T
M E
TA
L
S
O R
G A
N
IC
S
V
IA
B L
E S
M E
D
IC
A L
M O
L D
S am pl e
V ol um e
(L
A re a
S am pl e
Te m pe ra tu re
C
Le ng th (o r A liq uo ts
) x W id th
(o r A re a/
A liq uo t)
M at rix C od e of
C on ta in er s
D at e C ol le ct ed m m
/d d/ yy
T im e C ol le ct ed hh :m m
Eurofins Reservoirs Environmental, Inc Eurofins Reservoirs QA Manual
Effective September 06, 2023 Q:\QAQC\Eurofins Reservoirs QA Manual.pdf
(303) 964-1986
(866) RES-IENV
https://www.eurofinsus.com/builtenv https://clients.rei.et.eurofinsus.com
Appendix C
Photo Log
PHOTO 1: Ogden Weber tech Construction Trades
R & R Environmental, Inc.
47 West 9000 South, Suite #2, Sandy, Utah 84070
(801) 352-2380 • Fax: (801) 352-2381
SITE PHOTOGRAPHS
A LIMITED ASBESTOS SURVEY AND ASSESSMENT
OF THE
200 NORTH WASHINGTON BLVD
PROJECT NO:
DESIGNED BY:
SCALE:
REVIEWED
BY:
DRAWN BY:
DATE:
4-3-25
FILE:
Appendix D
State of Utah Certifications
Utah Asbestos Certification
State of Utah
SPENCER J. COX
Go,·emor
Depattment of Environmental Quality
Tim Davis lmerim Execlllil'e Director
DIVISION OF AIR QUALITY
Bryce C. Bird
Director
George Latu
ASB-7670 •·•~
Inspector 026) ·~
DEIDRE HENDERSON
Lie111ena111 Gol'emor
.-4t:£.~~ Director, Utah D,v,s,on of Air Quality
March 25, 2025
George Latu R&R Environmental, Inc.
47 West 9000 South, #2 Sandy, UT 84070
Dear Mr. Latu:
Re: Utah Asbestos Program Individual Certification Card
DAQA-001-25
The Utah Division of Air Quality (DAQ) has reviewed your Utah Asbestos Program Certification Application for Individuals and we are pleased to inform you that your application has been approved.
Your new asbestos program individual certification card is enclosed with this letter and this card is the sole method of individual certification documentation that you will receive from the DAQ.
Please check the information on your asbestos program certification card carefully. Please confirm that the photograph, name, and certification discipline(s) are correct. Also, please remember to keep your current asbestos program certification card with you at all times when you are performing regulated asbestos work activities.
Please contact Barbara Perkins at (801) 536-0221 or at bperkins@utah.gov if you have any questions regarding this letter or the enclosed asbestos program certification card.
Sincerely, ';!..J:v~ Leonard Wnght (Mar 25,02510:18 MDT)
Leonard Wright, Manager Air Toxics, Lead-Based Paint, and Asbestos Section
LW:BP:lr
195 North 1950 West, 4th Floor• Salt Lake City, UT Mailing Address: P.O. Box 144820 • Salt Lake City, UT 84114-4820
Telephone (801) 536-4000 • Fax (801) 536-4099 • T.D.D. (801) 536-4414 www.deq.utuli.gov
Printed on 100% recycled paper
Utah Lead-Based Paint Certification
State of Utah
SPENCER J. COX
Go,·tmor
DEIDRE HENDERSON
litutenant Gol'limor
February 11, 2025
Steve Smith
Department of Environmental Quality
Kimberly D. Shelley Exec11tfre Director
DIVISION OF AIR QUALITY
Bryce C Bird
Director
R&R Environmental, Inc.
4 7 West 9000 South, #2 Sandy, UT 84070
Dear Mr. Smith:
Re: Utah Lead-Based Paint Program Individual Certification Card
Inspector l Risk Aue
-4~;_·~
Director, Utah D1v1sion of Air Quality
DAQA-002-25
The Utah Division of Air Quality (DAQ) has reviewed your Utah Lead-Based Paint (LBP)
Program Certification Application for Individuals and we are pleased to inform you that your application has been approved. Your new LBP program individual certification card is enclosed with this letter and this card is the sole method of individual certification documentation that you will receive from the DAQ.
Please check the information on your LBP program certification card carefully. Please confirm that the photograph, name, and certification discipline(s) are correct. Also, please remember to keep your current LBP program certification card with you at all times when you are performing regulated LBP work activities.
Please contact Barbara Perkins at (80 l) 536-0221 or at bperkins@utah.gov if you have any questions regarding this letter or the enclosed LBP program certification card.
Sincerely, ~ Sl1J~ Leonard Wright (Feb 7, 2025 12:09 MST)
Leonard Wright, Manager Air Toxics, Lead-Based Paint, and Asbestos Section
LW:BP:lr
195 Nonh 1950 Wes,, 4~' Hoor • Sall Lake City, Ur Mailing Addrm l' 0 llo"< 144820 • Suh Lnl.c Cny. UT 84114-1820
'I elephone (80 I) 536-4000 • l·a"< (801) 536-4099 ·TDD (80 I) 536-1-11-1 ~• u ,, di:tJ mnh gm•
P11111cd on I00~. 1ccycled papc,
| DFCM_OTECH Construction Roof_Limited Hazmat_April 2025 |
| Table of Contents |
| Appendix A |
| SAMPLE LOG |
| Appendix B |
| 639862-1.pdf |
| DFCM_OTECH Construction Roof_Limited Hazmat_April 2025 |
| Table of Contents |
| SAMPLE LOG |
| Appendix C |
| Appendix D |
| Exp 3:30:2026.pdf |
| 2025 SBS : DCR ACM LBP.pdf |
| DAQ Card (Exp. 2025).pdf |
| SBS LBP Cert Exp Jan 2028.pdf |
| 2025 DCR ACM LBP.pdf |
{"type":"Document","isBackSide":false,"languages":["en-us"],"usedOnDeviceOCR":false}
{"type":"Document","isBackSide":false,"languages":["en-us"],"usedOnDeviceOCR":false}
File details come from the government source that posted it. Updated .