5-02 Plan Set.pdf
PDF 32 MB Posted
- Attached to
- Grady Littlejohn Park Improvements
- Solicitation number
- 26-11CSP
- Issued by
- Collin County, Texas
About this file
Summary: Grady Littlejohn Softball Complex Improvements - 100% Construction Document Plan Set
This is a comprehensive 100% construction document plan set for the Grady Littlejohn Softball Complex redevelopment project in McKinney, Texas, prepared by a multi-disciplinary design team including Conduit Architecture + Design, LJA Planning and Landscape Architecture, LJA Engineering, Salas O'Brien (electrical), and Jordan Consulting Engineers (structural). The project encompasses improvements to six softball fields, including field seating, a new concession and restroom building, and a pedestrian plaza at Towne Lake Park. Development Permit #2025-00075 was approved by the City of McKinney Engineering Department on January 27, 2026, with a pre-construction conference required prior to commencement. The plan set includes comprehensive sheets covering site preparation and erosion control, demolition, grading, drainage, utilities, hardscape design with concrete paving and terraced seating, site furnishings, shade structures, landscape irrigation, and planting plans. Key scope items include removal and reinstallation of existing bleachers, dugout benches, and bat racks; demolition of retaining walls and concrete seating areas; installation of new concrete pavement, handrails, and guardrails; addition of site furnishings such as picnic tables and litter receptacles; and establishment of new landscaping with trees and sodding. Tree protection is a critical requirement with designated areas fenced and protected throughout construction, and all existing trees to remain must be carefully preserved.
The construction documents are released for bidding with detailed specifications for materials including 4,000 PSI reinforced concrete pavement, steel railings and guardrails painted black, stainless steel bollards, and site furnishings from specified suppliers such as Anova Furnishings and Doty & Sons Concrete Products. Alternate bid items include limestone block benches in two types from Mezger Stone. The project requires contractor responsibility for all utility coordination, erosion control compliance, tree protection mitigation, and restoration of any damaged materials at no additional cost to the owner. Temporary irrigation is required for establishment of Bermuda grass sodding across 53,351 square feet of disturbed areas. The landscape irrigation system will be installed by Irri Tech LLC, with 20 canopy trees, nine ornamental trees, and 8,063 square feet of mulch beds specified. All work must comply with City of McKinney standards and ADA accessibility requirements, with maximum slopes of 5% for pedestrian surfaces and 6% for fire lanes. The project includes provisions for pre-construction meetings, field verification of all dimensions and utilities, and ongoing coordination with the landscape architect and structural, mechanical, electrical, and plumbing engineers throughout the construction process.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
TOWNE LAKE GRADY LITTLEJOHN
SOFTBALL COMPLEX
MCKINNEY · TEXAS
100% CONSTRUCTION DOCUMENTS
JOB No. NTP660-0157F
DATE: DECEMBER 17, 2025
LOCATION MAP
SHEET INDEX
COVER SHEET
NORTH CSNORTH
PROJECT
LOCATION
WILSON CREEK PKWY
IN
TE
R
ST
AT
E
MCKINNEY
HIGHSCHOOL
PA
RK
V
IE
W A
VE
TOWNE LAKE
S C
O
LL
EG
E
ST
ELDORADAO PKWY
S M
C D
O N
AL
D
S T
TOWNE LAKE PARK
LIGHTWALK
REVISIONS
ARCHITECT
PROJECT NUMBER
G R
AD
Y
LI
TT
LE
JO
H N
SO
FT
BA
LL
C O
M
PL
EX
M
C
KI
N N
EY
, T
EX
AS
NTP660-0157F
CLIENT
KEY MAP
LJA
2150 S Central Expressway Suite 300 McKinney, TX 75070
REMARKSDATEREVISION REMARKSDATEREVISION
ISSUE TITLE: ISSUE DATE:
PROJECT DESIGNER:DRAWN BY:
PROJECT MANAGER:
100% CONSTRUCTION
DOCUMENTS
12/17/25
BV
JS, TS JS
PROJECT
SHEET NO.
2150 South Central Expressway | Suite 380 | McKinney, Texas 75070 Phone 214.620.2800 FRN - F-1386
PLANNING | LANDSCAPE ARCHITECTURE
SHEET TITLE
DESIGN TEAM
PROJECT
SHEET NO.
2150 South Central Expressway | Suite 380 | McKinney, Texas 75070 Phone 214.620.2800 FRN - F-1386
PLANNING | LANDSCAPE ARCHITECTURE
SHEET TITLE
DESIGN TEAM
HI
B
C
ST
E C
CT
TE
SA
ET
S
TA
I
RE
G
OF
2 2
ET
X
C R
LDRE
CAANDS EP A
J R
L L
I
VJY
. II
SEAL
DECEMBER 17, 2025
CITY OF MCKINNEY
401 E. VIRGINIA ST.
MCKINNEY, TX 75069
TO
W
N E
LA
KE
DEVELOPMENT PERMIT
2025-00075
DOG PARK
DEVELOPMENT PERMIT SHEETS
CS COVER SHEET (THIS SHEET)
GN.00 GENERAL NOTES
GN.01 CITY STANDARD NOTES
GN.02 CITY STANDARD NOTES
KM.00 KEY MAP
TP.00 TREE PROTECTION OVERALL SITE PLAN
TP.01 TREE PROTECTION PLAN
TP.02 TREE PROTECTION PLAN
TP.03 TREE PROTECTION CHART
SP.01 SITE PREPARATION & EROSION CONTROL PLAN
SP.02 SITE PREPARATION & EROSION CONTROL PLAN
SP.03 SITE PREPARATION & EROSION CONTROL PLAN
SP.04 SITE PREPARATION & EROSION CONTROL DETAILS
DM.01 DEMOLITION PLAN
DM.02 DEMOLITION PLAN
CIVIL
C1.01 GRADING PLAN
C1.02 GRADING PLAN
C2.01 DRAINAGE PLAN
C3.01 UTILITY PLAN
C4.01 DETAILS
LANDSCAPE ARCHITECTURE
L1.00 HARDSCAPE MATERIALS LEGEND
L1.01A HARDSCAPE PLAN
L1.02A HARDSCAPE PLAN
L1.01B SITE FURNISHINGS PLAN
L1.02B SITE FURNISHINGS PLAN
L2.01 DIMENSIONAL CONTROL AND JOINTING PLAN
L2.02 DIMENSIONAL CONTROL AND JOINTING PLAN
L3.01 SHADE STRUCTURE LAYOUT PLAN
L3.02 SHADE STRUCTURE LAYOUT PLAN
L5.01 HARDSCAPE DETAILS
L5.02 HARDSCAPE DETAILS
L5.03 HARDSCAPE DETAILS
L5.04 HARDSCAPE DETAILS
L5.05 HARDSCAPE DETAILS
L5.06 HARDSCAPE DETAILS
L5.07 HARDSCAPE DETAILS
L5.08 HARDSCAPE DETAILS
L6.00 PLANTING LEGEND, DETAILS, & NOTES
L6.01 PLANTING PLAN
L6.02 PLANTING PLAN
IRRIGATION
IR1.00 LANDSCAPE IRRIGATION DETAILS, NOTES, & LEGEND
IR1.01 LANDSCAPE IRRIGATION PLAN
IR1.02 LANDSCAPE IRRIGATION PLAN
SUPPLEMENTAL SITE RENOVATION SHEETS
BUILDING ARCHITECTURAL
G0.00 COVER SHEET
G0.01 DRAWING INDEX & LOCATION INFO
A0.02 GRAPHIC SYMBOLS & ABBREVIATIONS
A0.03 CODE ANALYSIS
A0.04 PARTITION TYPES & DETAILS
A0.05 TEXAS ACCESSIBILITY STANDARDS
A0.06 TEXAS ACCESSIBILITY STANDARDS
A0.07 TEXAS ACCESSIBILITY STANDARDS
A0.08 TEXAS ACCESSIBILITY STANDARDS
A0.09 TEXAS ACCESSIBILITY STANDARDS
A0.10 TEXAS ACCESSIBILITY STANDARDS
A0.11 MOUNTING LOCATIONS
A0.12 ACCESSORY SCHEDULE
A1.00 SITE PLAN
A2.00 FLOOR PLAN
A2.01 ENLARGED DETAILS
A3.00 REFLECTED CEILING PLAN
A4.00 ROOF PLAN
A5.00 EXTERIOR ELEVATIONS
A5.01 EXTERIOR ELEVATIONS
A6.00 BUILDING SECTIONS
A6.01 WALL SECTIONS
A7.00 INTERIOR ELEVATIONS
A7.01 INTERIOR ELEVATIONS
A8.00 DOOR SCHEDULES
A8.01 FINISH SCHEDULE
BUILDING STRUCTURAL
S0.01 GENERAL NOTES
S0.04 STATEMENT OF STRUCTURAL SPECIAL INSPECTIONS
S1.00 FOUNDATION PLAN
S1.01 ROOF PLAN
S2.01 SLAB ON GRADE DETAILS
S2.02 TYPICAL SPREAD FOOTING DETAILS
S4.01 TYPICAL CMU DETAILS
S5.01 TYPICAL STEEL DETAILS
S5.02 TYPICAL STEEL DETAILS
BUILDING MECHANICAL
M2.01 FLOOR PLAN - MECHANICAL
M3.01 SCHEDULES & DETAILS MECHANICAL
M3.02 SCHEDULES & DETAILS MECHANICAL
M3.03 SCHEDULES & DETAILS MECHANICAL
BUILDING ELECTRICAL
E2.01 FLOOR PLAN - POWER & SYSTEMS
E3.01 FLOOR PLAN - LIGHTING (PLACE HOLDERS)
E4.01 DETAILS & SCHEDULES - ELECTRICAL
E4.02 DETAILS & SCHEDULES - ELECTRICAL
BUILDING PLUMBING
P2.00 UNDERFLOOR PLAN - PLUMBING
P2.01 ROOF PLAN - PLUMBING
P3.01 SCHEDULES & DETAILS PLUMBING
P3.02 RISERS DIAGRAMS - PLUMBING
SITE ELECTRICAL
E0.01 ELECTRICAL GENERAL NOTES AND DETAILS
E0.02 ELECTRICAL DETAILS
E1.00 ELECTRICAL SITE PLAN
E1.01 ELECTRICAL SITE LIGHTING PLAN
SITE STRUCTURAL
S1 STRUCTURAL DETAILS
S2 STRUCTURAL DETAILS
ELECTRICAL ENGINEER
SALAS O'BRIEN
CONTACT: GINNY GRIBBLE
106 DECKER DRIVE, SUITE 200
IRVING, TX 75062
PHONE: 469.949.8841
SITE STRUCTURAL
JORDAN CONSULTING ENGINEERS, INC.
CONTACT: GERALD JORDAN
ARLINGTON, TEXAS
EMAIL: GERALD@JORDANENGINEERS.COM
OWNER
THE CITY OF MCKINNEY
CONTACT: JILL YOUNT
401 E. VIRGINIA ST.
MCKINNEY, TX 75069
PHONE: 972.547.7490
LANDSCAPE ARCHITECT
LJA PLANNING AND LANDSCAPE ARCHITECTURE
CONTACT: BILLY VICIC
2150 SOUTH CENTRAL EXPRESSWAY | SUITE 300
McKINNEY, TEXAS 75070
PHONE: 214.620.2748
ARCHITECT
CONDUIT ARCHITECTURE + DESIGN
CONTACT: CHRISTOPHER BRAVO
711 N TENNESSEE ST
McKINNEY, TEXAS 75069
PHONE: 972.302.9747 EXT 703
THIS PACKAGE INCLUDES IMPROVEMENTS TO
THE FOLLOWING AREAS OF THE PROPERTY:
· FIELD SEATING
· CONCESSION AND RESTROOM BUILDING
· PEDESTRIAN PLAZA
BID ITEMS CIVIL ENGINEER
LJA ENGINEERING
CONTACT: RUTH RANGEL
2150 SOUTH CENTRAL EXPRESSWAY | SUITE 300
McKINNEY, TEXAS 75070
PHONE: 214.620.2800
IRRIGATION CONSULTANT
IRRI TECH
CONTACT: MARVIN PRESTRIDGE
12650 SCHROEDER RD
DALLAS, TX 75243
PHONE: 972.231.5151
DEVELOPMENT PERMIT #: 2025-00075
RELEASED FOR CONSTRUCTION
CITY OF McKINNEY ENGINEERING DEPARTMENT
January 27, 2026 by Jennifer Jackson, P.E.
Prior to commencing construction, the owner or their representative shall hold a Pre-Construction Conference with and be issued a Development Permit by the City of McKinney Engineering Department. A copy of the Development
Permit and these stamped construction drawings shall be maintained on the construction site at all times. If a conflict is found between these construction drawings and the City of McKinney Construction Standards, the City of McKinney Construction Standards shall govern.
X:\Development Services\EngineeringFiles\DEV\2025\DEV2025-00075 Grady Littlejohn Redevelopment\2026-01-15 Post Approval Submittal\2026.01.15 Grady Littlejohn_Revised Civil Development Plans.pdf 01/27/2026 4:06:04 PM Jennifer Jackson, P.E.
City of McKinney - Tree Preservation Ian Erickson - ISA Certified Arborist
Urban Forester ierickson@mckinneytexas.org
(972)547-9014 Tree Preservation
Approved 09/10/2025
GENERAL NOTES
1. THE CONTRACTOR SHALL BE RESPONSIBLE FOR TREE
PROTECTION. MAINTAIN EXISTING GRADE WITHIN DRIP
LINE OF ALL EXISTING TREES. THE CONTRACTOR SHALL
NOTIFY THE LANDSCAPE ARCHITECT BEFORE
COMMENCING WORK WHERE GRADING CONDITIONS
DICTATE MORE THAN 2" OF FILL WITHIN THE DRIP LINE.
2. THE CONTRACTOR IS RESPONSIBLE FOR THE
REPLACEMENT OF ANY EXISTING MATERIALS THAT ARE
DAMAGED DURING CONSTRUCTION, AS DETERMINED
BY THE OWNER'S AUTHORIZED REPRESENTATIVE.
3. NO CHANGE IN CONTRACT PRICE WILL BE ALLOWED
FOR ANY ACTUAL OR CLAIMED DISCREPANCY BETWEEN
EXISTING GRADES AND THOSE SHOWN ON PLANS
AFTER CONTRACTOR HAS ACCEPTED EXISTING
GRADES AND BEGUN WORK ON THE SITE.
4. CONTRACTOR SHALL BE RESPONSIBLE FOR ANY
COORDINATION WITH SUBCONTRACTORS AS REQUIRED
TO ACCOMPLISH GRADING OPERATIONS.
5. FILL AND GRADE SMOOTH ALL HOLES, DEPRESSIONS,
AND RUTS THAT ARE A RESULT OF WORK PERFORMED
UNDER THIS CONTRACT. ALL AREAS ARE TOO BE
GRADED SO AS TO PROVIDE POSITIVE DRAINAGE AND
OUTFALL.
6. FINISHED GRADE SHALL BE 1" BELOW ADJACENT
CURBS, PAVEMENT, AND WALKS.
7. ALL GRADES SHOWN ARE FINISH GRADE ELEVATIONS
UNLESS OTHERWISE NOTED ON THE DRAWINGS.
8. UNLESS NOTED, ALL FILL IS TO BE COMPACTED TO A
MINIMUM OF 95% STANDARD PROCTOR DENSITY WITHIN
3% OF OPTIMUM MOISTURE CONTENT. FILL TO BE
PLACED IN A MAXIMUM OF 6" LIFTS.
9. ANY CONCRETE, ROCK, OR MATERIAL DEEMED
UNSUITABLE FOR SUBGRADE, BY ENGINEER, SHALL BE
DISPOSED OF OFF SITE AT CONTRACTOR'S EXPENSE.
GRADING NOTES
1. CONTRACTOR SHALL STAKE LOCATIONS OF ALL PROPOSED
HARDSCAPE ELEMENTS FOR APPROVAL BY THE
LANDSCAPE ARCHITECT PRIOR TO CONSTRUCTION.
2. CONTRACTOR SHALL LAYOUT CURVILINEAR SIDEWALKS
AND PATHS SO AS TO MAKE SMOOTH AND CONTINUOUS
TRANSITIONS.
3. DIMENSIONS TAKEN FROM ROAD EDGE ARE TYPICALLY
FROM BACK OF CURB (B.O.C.) UNLESS OTHERWISE NOTED
ON THE PLAN. ALL DIMENSIONS TAKEN FROM CURBS,
BUILDING FACE, OR OTHER HARDSCAPE FEATURES ARE
TAKEN PERPENDICULAR UNLESS OTHERWISE NOTED ON
PLANS.
4. ALL HARDSCAPE ELEMENT DIMENSIONS ARE TO
CENTERLINE OF THE ELEMENT UNLESS OTHERWISE NOTED
ON THE PLANS.
5. THE ELEVATIONS OF ALL PROPOSED HARDSCAPE
ELEMENTS SHALL BE VERIFIED IN THE FIELD AND
APPROVED BY LANDSCAPE ARCHITECT.
6. CONTRACTOR IS REQUIRED TO SAFELY MAINTAIN
PEDESTRIAN TRAFFIC FLOW DURING CONSTRUCTION.
7. CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS.
8. ALL SIDEWALK AND TRAILS SHALL MEET ADA
REQUIREMENTS UNLESS OTHERWISE NOTED. MAXIMUM
CROSS SLOPE OF2% MINIMUM CROSS SLOPE OF 0.5% AND
MAXIMUM LONGITUDINAL SLOPE SHALL BE 5%.
CONTRACTOR SHALL BE RESPONSIBLE FOR REMOVAL AND
REPLACEMENT OF ANY ADA ACCESSIBLE FLATWORK THAT
DOES NOT MEET THE MINIMUM ADA ACCESSIBILITY
REQUIREMENTS AT NO ADDITIONAL COST TO THE OWNER.
9. GRADING OF ALL HANDICAPPED SPACES AND ROUTES TO
CONFORM TO STATE, LOCAL, AND FEDERAL GUIDELINES.
10. FINAL ENHANCED PAVING, AND SIDEWALK ELEVATIONS WILL
BE PLACED AT PLUS OR MINUS 0..03 FOOT.
11. MEET LEVEL AND FLUSH TO EXISTING RAMPS AND PROVIDE
5'X5' MINIMUM LANDING WITH A MAXIMUM 2% SLOPE IN ALL
DIRECTIONS.
12. END SIDEWALK AT EXPANSION JOINT BOARD AND DOWEL
FOR FUTURE CONNECTION, TYP.
13. THE PAVING CONTRACTOR IS RESPONSIBLE FOR ALL
"PERMANENT SURVEY REFERENCE MONUMENTS" AS
DESCRIBED IN THE SUBDIVISION ORDINANCE,
INCLUDING CONCRETE MONUMENTS AND ALL
BOUNDARY CORNERS
14. CONCRETE PAVING JOINTS SHALL BE CONSTRUCTED
AS SHOWN ON THE DRAWINGS AND DETAILS.
EXPANSION JOINTS SHALL BE PLACED AT CHANGES IN
DIRECTION OF PAVING, AT DRIVEWAYS, AND/OR AS
SHOWN ON THE DRAWINGS. SEAL ALL JOINTS AS
SHOWN ON THE DRAWINGS.
15. REFERENCE SIDEWALK DETAILS FOR MINIMUM P.S.I,
AND STRUCTURAL REINFORCEMENT REQUIREMENTS.
16. CONTRACTOR SHALL PROTECT EXISTING
MONUMENTATION AND PRIMARY CONTROL. ANY SUCH
POINTS WHICH THE CONTRACTOR BELIEVES WILL BE
DESTROYED SHALL HAVE OFFSET POINTS
ESTABLISHED BY THE CONTRACTOR PRIOR TO
CONSTRUCTION. ANY MONUMENTATION DESTROYED
BY THE CONTRACTOR SHALL BE REESTABLISHED AT
NO ADDITIONAL COST TO THE OWNER.
17. CONTRACTOR SHALL LOCATE AND ADJUST EXISTING
MANHOLE, LIDS, WATER VALVES,AND OTHER
SURFACES APPURTENANCES AS REQUIRED FOR NEW
CONSTRUCTION. CONTRACTOR SHALL COORDINATE
UTILITY ADJUSTMENTS WITH OTHER DISCIPLINES AND
THE APPROPRIATE AGENCIES AND PROVIDE FOR ALL
FEES FOR PERMITS, CONNECTIONS, INSPECTIONS,
ETC.
1. CONTRACTOR SHALL ACT IN ACCORDANCE WITH ALL
APPLICABLE LOCAL CODES, ORDINANCES,
SPECIFICATIONS, AND STANDARDS ENFORCED AT THE
TIME OF CONSTRUCTION.
2. CONTRACTOR IS RESPONSIBLE FOR, AND MUST OBTAIN
PRIOR TO CONSTRUCTION, ALL NECESSARY
CONSTRUCTION PERMITS REQUIRED BY THE GOVERNING
AGENCY.
3. PRIOR TO CONSTRUCTION, A PRE-CONSTRUCTION
MEETING SHALL BE HELD WITH REPRESENTATIVES FROM
ALL CONTRACTORS, LANDSCAPE ARCHITECT AND THE
OWNER.
4. TOPOGRAPHICAL MAPPING SHOWN PROVIDED BY LJA
ENGINEERING. CONTRACTOR TO NOTIFY ARCHITECT OF
ANY DISCREPANCIES BETWEEN THE PLAN TOPOGRAPHY
AND THE CURRENT EXISTING CONDITIONS.
5. CONTRACTOR IS RESPONSIBLE FOR VERIFYING THE
ACCURATE LOCATIONS OF PROPERTY LINES, RIGHT OF
WAY AND FUTURE CONSTRUCTION EASEMENTS AND
SHALL NOTIFY THE LANDSCAPE ARCHITECT OF ANY
DISCREPANCIES PRIOR TO CONSTRUCTION.
6. CONTRACTOR SHALL KEEP PROJECT SITE CLEAN AND
ORDERLY. IT WILL BE UNACCEPTABLE TO ALLOW TRASH
TO BLOW ONTO ADJACENT PROPERTIES. STRICT
ATTENTION WILL BE PAID TO THIS ITEM. IF CONTRACTOR
FAILS TO ADHERE TO THIS STIPULATION, OWNER
RESERVES THE RIGHT TO STOP WORK UNTIL TRASH IS
CLEANED UP. THIS STOPPAGE OF WORK WILL NOT
EXTEND THE ORIGINAL CONTRACT.
7. EXISTING UTILITIES SHOWN ARE TAKEN FROM AVAILABLE
RECORDS PROVIDED BY THE UTILITY OWNER AND FILE
LOCATIONS OF SURFACE APPURTENANCES. LOCATIONS
SHOWN ARE GENERALLY SCHEMATIC IN NATURE AND
MAY NOT ACCURATELY REFLECT THE SIZE AND LOCATION
OF EACH PARTICULAR UTILITY. SOME UTILITY LINES MAY
NOT BE SHOWN. CONTRACTOR SHALL VERIFY THE
LOCATION, SIZE, AND MATERIAL OF ALL UTILITIES
AFFECTED BY CONSTRICTION PRIOR TO BEGINNING
CONSTRUCTION. CONTRACTOR SHALL CONTACT ALL
AFFECTED UTILITY COMPANIES 48 HOURS PRIOR TO
CONSTRUCTION. FOR UTILITY LOCATION AND TO OBTAIN
A LIST OF KNOWN UTILITY COMPANIES, CONTRACTOR
SHALL CONTACT TEXAS 811.
8. CONTRACTOR TO NOTIFY THE OWNER WHEN ANY
DISCREPANCY IS FOUND BETWEEN PLANS AND EXISTING
CONDITIONS. IN THE EVENT A DISCREPANCY IS FOUND
THE CONTRACTOR WILL NOTIFY THE LANDSCAPE
ARCHITECT AND MAKE FIELD ADJUSTMENTS TO
CORRECT ANY PROBLEM.
9. CONTRACTOR SHALL REPAIR ANY AND ALL UTILITIES
THAT ARE DAMAGED DURING INSTALLATION AT NO
ADDITIONAL COST TO THE CLIENT.
10. NO TRAFFIC SIGNS ARE TO BE RELOCATED OR REMOVED
WITHOUT PRIOR APPROVAL. SIGNS ALONG ROUTE
REMOVED FOR CONVENIENCE OF CONSTRUCTION SHALL
BE REESTABLISHED AFTER COMPLETION OF BACKFILLING
IN THAT AREA.
11. CONTRACTOR IS RESPONSIBLE FOR REPLACEMENT OF
ANY EXISTING MATERIALS THAT ARE DAMAGED DURING
CONSTRUCTION, AS DETERMINED BY THE LANDSCAPE
ARCHITECT OR OWNER'S AUTHORIZED REPRESENTATIVE.
12. THE CONTRACTOR IS RESPONSIBLE FOR SECURING
ACCESS TO THE CONSTRUCTION SITE, SUBJECT TO
APPROVAL FROM THE CLIENT.
13. CONTRACTOR SHALL CONSTRUCT A STABILIZED
CONSTRUCTION ENTRANCE/EXIT AT ALL TRAFFIC ACCESS
POINTS PRIOR TO EXITING ONTO ANY PAVED ROADWAY.
REFERENCE CIVIL EROSION CONTROL PLANS FOR
DETAILS.
14. THE CONTRACTOR IS RESPONSIBLE FOR KEEPING
SIDEWALKS AND ROADS ADJACENT TO THE PROJECT
SITE FREE FROM MUD AND DEBRIS FROM THE
CONSTRUCTION SITE.
15. CONTRACTOR SHALL PERFORM WORK IN A MANNER
CONSISTENT WITH ALL REGULATIONS TO ELIMINATE
HAZARDS TO PERSONS OR PROPERTY AND AVOID
INTERFERENCE WITH ADJACENT AREAS, UTILITIES, AND
STRUCTURES.
16. THE ACCESS AND WORK AREAS SHALL BE SECURED
DURING NON WORKING HOURS.
17. THE CONTRACTOR SHALL ADOPT APPROPRIATE
CONSTRUCTION SITE MANAGEMENT PRACTICES TO
PREVENT THE DISCHARGE OF OILS, GREASE, PAINTS,
GASOLINE AND OTHER POLLUTANTS TO STORM WATER.
APPROPRIATE PRACTICES SHALL BE INCIDENTAL TO
THE OVERALL PROJECT COSTS AND INCLUDE BUT ARE
NOT LIMITED TO:
-DESIGNATING AREAS FOR EQUIPMENT MAINTENANCE
AND REPAIR
-REGULAR COLLECTION OF WASTE
-CONVENIENTLY LOCATED TRASH RECEPTACLES
-DESIGNATING AND CONTROLLING EQUIPMENT
WASHDOWN
18. ADEQUATE MEASURES SHALL BE TAKEN TO PREVENT
EROSION. IN THE EVENT THAT SIGNIFICANT EROSION
OCCURS AS A RESULT OF CONSTRUCTION, THE
CONTRACTOR SHALL RESTORE THE AFFECTED AREAS
TO ORIGINAL CONDITION OR BETTER.
19. THESE PLANS DO NOT EXTEND TO OR INCLUDE
DESIGNS OR SYSTEMS PERTAINING TO THE SAFETY OF
THE CONSTRUCTION CONTRACTOR OR ITS EMPLOYEES,
AGENT OR REPRESENTATIVES IN PERFORMANCE OF
THE WORK. THE CONSTRUCTION CONTRACTOR SHALL
PREPARE AND OBTAIN THE APPROPRIATE SAFETY
SYSTEMS, INCLUDING PLANS AND SPECIFICATIONS
CERTIFIED BY A PROFESSIONAL ENGINEER LICENSED IN
THE STATE OF TEXAS, AND SUBMIT THE TRENCH
SAFETY SYSTEM SHOP DRAWINGS TO THE CITY FOR
APPROVAL PRIOR TO CONSTRUCTION.
20. ARRANGEMENTS FOR CONSTRUCTION WATER SHALL
BE MADE THROUGH THE CITY OF MCKINNEY AND SHALL
BE AT THE METERED EXPENSE OF THE CONTRACTOR.
21. THE CONTRACTOR SHALL USE THE PUBLIC
RIGHT-OF-WAYS AND EXISTING UTILITY EASEMENTS
FOR ACCESS TO THE JOB SITE.
22. CONSTRUCTION STAGING AREA OR STORAGE YARDS
SHALL BE OBTAINED PRIOR TO CONSTRUCTION.
CONTRACTOR IS RESPONSIBLE FOR SECURING THESE
LOCATIONS AND SHALL RETURN THE USED LOCATIONS
TO ORIGINAL CONDITION OR BETTER UNLESS
OTHERWISE SPECIFIED OR AGREED TO BY THE
PROPERTY OWNER.
23. ANY DAMAGES THAT MAY OCCUR TO REAL PROPERTY
OR EXISTING IMPROVEMENTS SHALL BE RESTORED BY
THE CONTRACTOR TO AT LEAST THE SAME CONDITION
THE REAL PROPERTY OR EXISTING IMPROVEMENTS
WERE IN PRIOR TO THE DAMAGES. THIS RESTORATION
SHALL BE SUBJECT TO OWNER'S APPROVAL;
MOREOVER, THE RESTORATION SHALL NOT BE A BASIS
FOR ADDITIONAL COMPENSATION TO THE
CONTRACTOR.
24. LOT LINES SHOWN ON SURVEY CONTROL AND SHEET
INDEXES ARE SHOWN FOR SCHEMATIC PURPOSES
ONLY.
25. THE LOCATION OF FEATURES TO BE
CONSTRUCTED AND NOT SPECIFICALLY
DIMENSIONED MAY BE DETERMINED BY SCALE. IF
CONFLICTS ARISE IN THE FIELD, NOTIFY THE
LANDSCAPE ARCHITECT FOR RESOLUTION.
26. IF THE IN-FIELD SCALED DIMENSIONS CONFLICT WITH
NO TED GRADES, AND/OR ELEVATIONS, NOTIFY THE
LANDSCAPE ARCHITECT TO RESOLVE
DISCREPANCIES.
27. PROTECT AND MAINTAIN ROADWAY TRAFFIC
THROUGHOUT THE PROJECT, PROVIDING A MINIMUM OF
ONE (1) LANE OPEN IN EACH DIRECTION.
28. PROVIDE AND MAINTAIN INTERIM ACCESS FROM
ROADWAYS CURRENTLY IN USE TO ALL DRIVEWAYS
AND INTERSECTING STREETS OR ALLEYS.
29. BARRICADING AND PROJECT SIGNS SHALL CONFORM
TO TEXAS DEPARTMENT OF TRANSPORTATION MANUAL
OF UNIFORM TRAFFIC CONTROL DEVICES AND LATEST
UPDATES.
30. UNLESS NOTED, ALL FILL IS TO BE COMPACTED TO A
MINIMUM OF 95% STANDARD PROCTOR DENSITY
WITHIN 3% OF OPTIMUM MOISTURE CONTENT. FILL TO
BE PLACED IN A MAXIMUM OF 6" LIFTS.
31. ALL INTERSECTIONS SHALL ADHERE TO VISIBILITY
TRIANGLE REQUIREMENTS OF THE LOCAL GOVERNING
BODY.
HARDSCAPE NOTES
1. THE CONTRACTOR SHALL VERIFY THE LOCATION OF ALL
DESIGNATED CLEARING AREAS, TREES, AND SHRUBS WITH
THE LANDSCAPE ARCHITECT PRIOR TO CLEARING
ACTIVITIES.
2. THE CONTRACTOR SHALL REMOVE ONLY THOSE TREES
AND SHRUBS WITHIN THE CLEARING AREAS DESIGNATED
BY THE LANDSCAPE ARCHITECT.
3. THE CONTRACTOR SHALL COMPLETELY REMOVE STUMPS,
ROOTS AND OTHER DEBRIS PROTRUDING THROUGH THE
GROUND SURFACE TO A MINIMUM DEPTH OF 12".
4. THE CONTRACTOR SHALL REMOVE ALL SURFACE ROCKS,
DEAD AND DELETERIOUS MATERIAL, AND TRASH FROM
CONSTRUCTION AREA.
5. ANY PROTECTED TREE THAT IS DAMAGED OR REMOVED
PRIOR TO CLIENT APPROVAL SHALL BE MITIGATED PER
THE GOVERNING AGENCIES REQUIREMENTS BY THE
CONTRACTOR AT NO ADDITIONAL COST TO THE CLIENT.
6. ALL TREES ARE TO REMAIN UNLESS OTHERWISE NOTED.
EXTREME CAUTION AND CARE IS TO BE TAKEN WHEN
INSTALLING PROPOSED IMPROVEMENTS AROUND TREES.
7. AREA TO RECEIVE SELECT CLEARING AND GRUBBING
BASED ON IN FIELD DIRECTION FROM THE LANDSCAPE
ARCHITECT. CONTRACTOR IS TO USE EXTREME CAUTION
WITH MINIMAL ASSISTANCE FROM MACHINERY EQUIPMENT
IN ORDER TO PREVENT DAMAGE TO REMAINING TREES.
CLEARING NOTES
GENERAL NOTES GENERAL NOTES (CONTINUED) HARDSCAPE NOTES (CONTINUED)
GN.00
REVISIONS
ARCHITECT
PROJECT NUMBER
G R
AD
Y
LI
TT
LE
JO
H N
SO
FT
BA
LL
C O
M
PL
EX
M
C
KI
N N
EY
, T
EX
AS
NTP660-0157F
CLIENT
KEY MAP
LJA
2150 S Central Expressway Suite 300 McKinney, TX 75070
REMARKSDATEREVISION REMARKSDATEREVISION
ISSUE TITLE: ISSUE DATE:
PROJECT DESIGNER:DRAWN BY:
PROJECT MANAGER:
100% CONSTRUCTION
DOCUMENTS
12/17/25
BV
JS, TS JS
PROJECT
SHEET NO.
2150 South Central Expressway | Suite 380 | McKinney, Texas 75070 Phone 214.620.2800 FRN - F-1386
PLANNING | LANDSCAPE ARCHITECTURE
SHEET TITLE
DESIGN TEAM
PROJECT
SHEET NO.
2150 South Central Expressway | Suite 380 | McKinney, Texas 75070 Phone 214.620.2800 FRN - F-1386
PLANNING | LANDSCAPE ARCHITECTURE
SHEET TITLE
DESIGN TEAM
HI
B
C
ST
E C
CT
TE
SA
ET
S
TA
I
RE
G
OF
2 2
ET
X
C R
LDRE
CAANDS EP A
J R
L L
I
VJY
. II
SEAL
DECEMBER 17, 2025
CITY OF MCKINNEY
401 E. VIRGINIA ST.
MCKINNEY, TX 75069
TO
W
N E
LA
KE
DEVELOPMENT PERMIT
2025-00075
CITY STANDARD
NOTES
GN.01
REVISIONS
ARCHITECT
PROJECT NUMBER
G R
AD
Y
LI
TT
LE
JO
H N
SO
FT
BA
LL
C O
M
PL
EX
M
C
KI
N N
EY
, T
EX
AS
NTP660-0157F
CLIENT
KEY MAP
LJA
2150 S Central Expressway Suite 300 McKinney, TX 75070
REMARKSDATEREVISION REMARKSDATEREVISION
ISSUE TITLE: ISSUE DATE:
PROJECT DESIGNER:DRAWN BY:
PROJECT MANAGER:
100% CONSTRUCTION
DOCUMENTS
12/17/25
BV
JS, TS JS
PROJECT
SHEET NO.
2150 South Central Expressway | Suite 380 | McKinney, Texas 75070 Phone 214.620.2800 FRN - F-1386
PLANNING | LANDSCAPE ARCHITECTURE
SHEET TITLE
DESIGN TEAM
PROJECT
SHEET NO.
2150 South Central Expressway | Suite 380 | McKinney, Texas 75070 Phone 214.620.2800 FRN - F-1386
PLANNING | LANDSCAPE ARCHITECTURE
SHEET TITLE
DESIGN TEAM
HI
B
C
ST
E C
CT
TE
SA
ET
S
TA
I
RE
G
OF
2 2
ET
X
C R
LDRE
CAANDS EP A
J R
L L
I
VJY
. II
SEAL
DECEMBER 17, 2025
CITY OF MCKINNEY
401 E. VIRGINIA ST.
MCKINNEY, TX 75069
TO
W
N E
LA
KE
CITY STANDARD
NOTES
GN.02
REVISIONS
ARCHITECT
PROJECT NUMBER
G R
AD
Y
LI
TT
LE
JO
H N
SO
FT
BA
LL
C O
M
PL
EX
M
C
KI
N N
EY
, T
EX
AS
NTP660-0157F
CLIENT
KEY MAP
LJA
2150 S Central Expressway Suite 300 McKinney, TX 75070
REMARKSDATEREVISION REMARKSDATEREVISION
ISSUE TITLE: ISSUE DATE:
PROJECT DESIGNER:DRAWN BY:
PROJECT MANAGER:
100% CONSTRUCTION
DOCUMENTS
12/17/25
BV
JS, TS JS
PROJECT
SHEET NO.
2150 South Central Expressway | Suite 380 | McKinney, Texas 75070 Phone 214.620.2800 FRN - F-1386
PLANNING | LANDSCAPE ARCHITECTURE
SHEET TITLE
DESIGN TEAM
PROJECT
SHEET NO.
2150 South Central Expressway | Suite 380 | McKinney, Texas 75070 Phone 214.620.2800 FRN - F-1386
PLANNING | LANDSCAPE ARCHITECTURE
SHEET TITLE
DESIGN TEAM
HI
B
C
ST
E C
CT
TE
SA
ET
S
TA
I
RE
G
OF
2 2
ET
X
C R
LDRE
CAANDS EP A
J R
L L
I
VJY
. II
SEAL
DECEMBER 17, 2025
CITY OF MCKINNEY
401 E. VIRGINIA ST.
MCKINNEY, TX 75069
TO
W
N E
LA
KE
54854
TOWNE LAKE
WILSON CREEK PARKWAY
WILSON CREEK TRAIL
FIELD 1
FIELD 2
FIELD 3
FIELD 4
FIELD 5
FIELD 6
KEY MAP
(FEET)
1 inch = ft.
6030 120
SCALE:A KEY MAP
1"= 60' PLAN
NORTH KM.00
REVISIONS
ARCHITECT
PROJECT NUMBER
G R
AD
Y
LI
TT
LE
JO
H N
SO
FT
BA
LL
C O
M
PL
EX
M
C
KI
N N
EY
, T
EX
AS
NTP660-0157F
CLIENT
KEY MAP
LJA
2150 S Central Expressway Suite 300 McKinney, TX 75070
REMARKSDATEREVISION REMARKSDATEREVISION
ISSUE TITLE: ISSUE DATE:
PROJECT DESIGNER:DRAWN BY:
PROJECT MANAGER:
100% CONSTRUCTION
DOCUMENTS
12/17/25
BV
JS, TS JS
PROJECT
SHEET NO.
2150 South Central Expressway | Suite 380 | McKinney, Texas 75070 Phone 214.620.2800 FRN - F-1386
PLANNING | LANDSCAPE ARCHITECTURE
SHEET TITLE
DESIGN TEAM
PROJECT
SHEET NO.
2150 South Central Expressway | Suite 380 | McKinney, Texas 75070 Phone 214.620.2800 FRN - F-1386
PLANNING | LANDSCAPE ARCHITECTURE
SHEET TITLE
DESIGN TEAM
HI
B
C
ST
E C
CT
TE
SA
ET
S
TA
I
RE
G
OF
2 2
ET
X
C R
LDRE
CAANDS EP A
J R
L L
I
VJY
. II
SEAL
DECEMBER 17, 2025
CITY OF MCKINNEY
401 E. VIRGINIA ST.
MCKINNEY, TX 75069
TO
W
N E
LA
KE
DEVELOPMENT PERMIT
2025-00075
RE: A/LX.01
RE: B/LX.01
RE: A/LX.02
RE: A/SP.03
RELEASED FOR CONSTRUCTION
CITY OF McKINNEY ENGINEERING DEPARTMENT
January 27, 2026 by Jennifer Jackson, P.E.
Prior to commencing construction, the owner or their representative shall hold a Pre-Construction Conference with and be issued a Development Permit by the City of McKinney Engineering Department. A copy of the Development
Permit and these stamped construction drawings shall be maintained on the construction site at all times. If a conflict is found between these construction drawings and the City of McKinney Construction Standards, the City of McKinney Construction Standards shall govern.
X:\Development Services\EngineeringFiles\DEV\2025\DEV2025-00075 Grady Littlejohn Redevelopment\2026-01-15 Post Approval Submittal\2026.01.15 Grady Littlejohn_Revised Civil Development Plans.pdf 01/27/2026 4:06:13 PM Jennifer Jackson, P.E.
54854
TOWNE LAKE
WILSON CREEK PARKWAY
WILSON CREEK TRAIL
FIELD 1
FIELD 2
FIELD 3
FIELD 4
FIELD 5
FIELD 6
ALL EXISTING SITE PERIMETER
TREES TO REMAIN AND BE
PROTECTED, TYP.
TREE PROTECTION
OVERALL SITE PLAN
(FEET)
1 inch = ft.
6030 120
SCALE:A TREE PROTECTION SITE PLAN
1"= 60' PLAN
NORTH TP.00
REVISIONS
ARCHITECT
PROJECT NUMBER
G R
AD
Y
LI
TT
LE
JO
H N
SO
FT
BA
LL
C O
M
PL
EX
M
C
KI
N N
EY
, T
EX
AS
NTP660-0157F
CLIENT
KEY MAP
LJA
2150 S Central Expressway Suite 300 McKinney, TX 75070
REMARKSDATEREVISION REMARKSDATEREVISION
ISSUE TITLE: ISSUE DATE:
PROJECT DESIGNER:DRAWN BY:
PROJECT MANAGER:
100% CONSTRUCTION
DOCUMENTS
12/17/25
BV
JS, TS JS
PROJECT
SHEET NO.
2150 South Central Expressway | Suite 380 | McKinney, Texas 75070 Phone 214.620.2800 FRN - F-1386
PLANNING | LANDSCAPE ARCHITECTURE
SHEET TITLE
DESIGN TEAM
PROJECT
SHEET NO.
2150 South Central Expressway | Suite 380 | McKinney, Texas 75070 Phone 214.620.2800 FRN - F-1386
PLANNING | LANDSCAPE ARCHITECTURE
SHEET TITLE
DESIGN TEAM
HI
B
C
ST
E C
CT
TE
SA
ET
S
TA
I
RE
G
OF
2 2
ET
X
C R
LDRE
CAANDS EP A
J R
L L
I
VJY
. II
SEAL
DECEMBER 17, 2025
CITY OF MCKINNEY
401 E. VIRGINIA ST.
MCKINNEY, TX 75069
TO
W
N E
LA
KE
DEVELOPMENT PERMIT
2025-00075
RE: A/TP.01
RE: B/TP.01
GENERAL NOTES
1. THE FOLLOWING PRACTICES SHALL BE FOLLOWED FOR ENTIRE AREA WITHIN TREE PROTECTION FENCE:
· ALL WORK WITHIN 15 FEET OF EXISTING TREE TRUCKS SHALL BE DONE BY HAND.
· WHERE TRENCHING IS REQUIRED, EXCAVATE UNDER OR AROUND TREE ROOTS BY HAND OR WITH AIR SPADE, OR TUNNEL UNDER ROOTS
BY HORIZONTAL AUGER BORING. DO NOT CUT MAIN LATERAL TREE ROOTS OR TAPROOTS. ONLY CUT ROOTS LESS THAN 1/2" DIA. WHICH
INTERFERE WITH INSTALLATION OF UTILITIES.
· ALL ROOTS 2" OR LARGER IN CALIPER THAT ARE CUT WITHIN HARDSCAPE PATH FOOTPRINT SHALL BE CUT OFF SQUARE.
· DO NOT ALLOW EXPOSED ROOTS TO DRY OUT BEFORE PLACING PERMANENT BACKFILL.
· DO NOT DIRECT VEHICLE OR EQUIPMENT EXHAUST TOWARD PROTECTION ZONES.
· PROHIBIT HEAT SOURCES, FLAMES, IGNITION SOURCES, AND SMOKING WITHIN OR NEAR TREE PROTECTION ZONES.
2. THE FOLLOWING PRACTICES ARE PROHIBITED WITHIN TREE PROTECTION FENCING:
· STORAGE OF CONSTRUCTION MATERIALS, DEBRIS, OR EXCAVATION MATERIAL
· MOVING OR PARKING VEHICLES, HEAVY MACHINERY OR EQUIPMENT
· CONCENTRATED FOOT TRAFFIC
· ERECTION OF SHEDS OR STRUCTURES
· IMPOUNDMENT OF WATER
· EXCAVATION OR DIGGING UNLESS WITHIN THE FOOTPRINT OF PROPOSED SITE HARDSCAPE ELEMENTS
· ATTACHMENT OF SIGNS TO OR WRAPPING MATERIALS AROUND TREES UNLESS OTHERWISE DIRECTED
3. ALL TREES ARE TO REMAIN UNLESS OTHERWISE NOTED. EXTREME CAUTION AND CARE IS TO BE TAKEN WHEN PERFORMING SELECTIVE TREE
REMOVAL AND WHEN INSTALLING PROPOSED IMPROVEMENTS AROUND TREES TO REMAIN.
4. CONTRACTOR SHALL PERFORM SELECTIVE TREE REMOVAL BY REMOVING ONLY TREES WHICH HAVE BEEN DESIGNATED PER THE PLANS.
CONTRACTOR IS TO USE EXTREME CAUTION WITH MINIMAL ASSISTANCE FROM MACHINERY EQUIPMENT IN ORDER TO PREVENT DAMAGE TO
EXISTING TREES TO REMAIN.
5. UNDER TREE CANOPY OF EXISTING TREES TO REMAIN, CONTRACTOR SHALL CUT TREE TRUNKS TO LEVEL OF EXISTING GRADE AND LEAVE ROOTS IN PLACE TO AVOID DAMAGE TO ROOT SYSTEMS OF AN ADJACENT TREE. WHEN TREE STUMP IS LOCATED WITHIN PROPOSED HARDSCAPE FOOTPRINT, CONTRACTOR SHALL COMPLETELY REMOVE STUMP AND ROOTS WHICH PROTRUDE THROUGH THE GROUND SURFACE TO A MINIMUM
DEPTH OF 8" WITHIN THE EXTENTS OF THE PROPOSED HARDSCAPE ELEMENT.
6. ANY PROTECTED TREE THAT IS DAMAGED OR REMOVED PRIOR TO CLIENT OR LANDSCAPE ARCHITECT APPROVAL SHALL BE MITIGATED PER THE GOVERNING AGENCIES REQUIREMENTS BY THE CONTRACTOR AT NO ADDITIONAL COST TO THE CLIENT.
TREE PROTECTION LEGEND
SYMBOL DESCRIPTION SYMBOL DESCRIPTION
EXISTING TREE TO REMAIN
AND BE PROTECTED EXISTING CONTOUR
EXISTING TREE CANOPY EXISTING LIGHT POLE
TREE PROTECTION
FENCING
RE: TP.03
EXISTING TREE TO BE
REMOVED
RE: DM.01 - DM.02
RE: A/TP.02
FIELD 1
FIELD 6
M
AT
C H
LI
N
E 'A
R
E:
A
/T P.
M
AT
C H
LI
N
E 'A
R
E:
A
/T P.
EXISTING TREE TO BE
REMOVED, TYP.
RE: DM.00 SERIES
EXISTING TREE TO BE
REMOVED, TYP.
RE: DM.00 SERIES
EXISTING FIELD LIGHT
POLE, TYP.
EXISTING FENCE, TYP.
EXISTING FIELD LIGHT
POLE, TYP.
EXISTING FENCE, TYP.
EXISTING IRRIGATION
BOX, TYP.
EXISTING IRRIGATION
BOX, TYP.
EXISTING CONCRETE
SIDEWALK, TYP.
EXISTING IRRIGATION
BOX, TYP.
EXISTING CONCRETE
SIDEWALK, TYP.
EXISTING TREE TO
REMAIN, TYP.
EXISTING TREE TO
REMAIN, TYP.
APPROXIMATE LOCATION OF
EXISTING SANITARY SEWER
APPROXIMATE LOCATION OF
EXISTING WATER LINE
54854
7FIELD 3
FIELD 4
EXISTING FIELD LIGHT
POLE, TYP.
EXISTING FENCE, TYP.
EXISTING BOLLARDS,
TYP.
EXISTING CONCRETE
SIDEWALK, TYP.
M
AT
C H
LI
N
E 'B
R
E:
B
/T P.
M
AT
C H
LI
N
E 'B
R
E:
A
/T P.
LI
M
IT
O
F W
O R
K R
E:
D
O G
P
AR
K
PL
AN
S
REVISIONS
ARCHITECT
PROJECT NUMBER
G R
AD
Y
LI
TT
LE
JO
H N
SO
FT
BA
LL
C O
M
PL
EX
M
C
KI
N N
EY
, T
EX
AS
NTP660-0157F
CLIENT
KEY MAP
LJA
2150 S Central Expressway Suite 300 McKinney, TX 75070
REMARKSDATEREVISION REMARKSDATEREVISION
ISSUE TITLE: ISSUE DATE:
PROJECT DESIGNER:DRAWN BY:
PROJECT MANAGER:
100% CONSTRUCTION
DOCUMENTS
12/17/25
BV
JS, TS JS
PROJECT
SHEET NO.
2150 South Central Expressway | Suite 380 | McKinney, Texas 75070 Phone 214.620.2800 FRN - F-1386
PLANNING | LANDSCAPE ARCHITECTURE
SHEET TITLE
DESIGN TEAM
PROJECT
SHEET NO.
2150 South Central Expressway | Suite 380 | McKinney, Texas 75070 Phone 214.620.2800 FRN - F-1386
PLANNING | LANDSCAPE ARCHITECTURE
SHEET TITLE
DESIGN TEAM
HI
B
C
ST
E C
CT
TE
SA
ET
S
TA
I
RE
G
OF
2 2
ET
X
C R
LDRE
CAANDS EP A
J R
L L
I
VJY
. II
SEAL
DECEMBER 17, 2025
CITY OF MCKINNEY
401 E. VIRGINIA ST.
MCKINNEY, TX 75069
TO
W
N E
LA
KE
DEVELOPMENT PERMIT
2025-00075
TREE PROTECTION
PLAN
(FEET)
1 inch = ft.
2010 40
SCALE:A TREE PROTECTION PLAN
1"= 20' PLAN
NORTH TP.01
SCALE:B TREE PROTECTION PLAN
1"= 20' PLAN (FEET)
1 inch = ft.
2010 40
NORTH
TREE PROTECTION LEGEND
SYMBOL DESCRIPTION SYMBOL DESCRIPTION
EXISTING TREE TO REMAIN
AND BE PROTECTED EXISTING CONTOUR
EXISTING TREE CANOPY EXISTING LIGHT POLE
TREE PROTECTION
FENCING
RE: TP.03
EXISTING TREE TO BE
REMOVED
RE: DM.01 - DM.02
GENERAL NOTES
1. THE FOLLOWING PRACTICES SHALL BE FOLLOWED FOR ENTIRE AREA WITHIN TREE PROTECTION FENCE:
· ALL WORK WITHIN 15 FEET OF EXISTING TREE TRUCKS SHALL BE DONE BY HAND.
· WHERE TRENCHING IS REQUIRED, EXCAVATE UNDER OR AROUND TREE ROOTS BY HAND OR WITH AIR SPADE, OR TUNNEL UNDER ROOTS
BY HORIZONTAL AUGER BORING. DO NOT CUT MAIN LATERAL TREE ROOTS OR TAPROOTS. ONLY CUT ROOTS LESS THAN 1/2" DIA. WHICH
INTERFERE WITH INSTALLATION OF UTILITIES.
· ALL ROOTS 2" OR LARGER IN CALIPER THAT ARE CUT WITHIN HARDSCAPE PATH FOOTPRINT SHALL BE CUT OFF SQUARE.
· DO NOT ALLOW EXPOSED ROOTS TO DRY OUT BEFORE PLACING PERMANENT BACKFILL.
· DO NOT DIRECT VEHICLE OR EQUIPMENT EXHAUST TOWARD PROTECTION ZONES.
· PROHIBIT HEAT SOURCES, FLAMES, IGNITION SOURCES, AND SMOKING WITHIN OR NEAR TREE PROTECTION ZONES.
2. THE FOLLOWING PRACTICES ARE PROHIBITED WITHIN TREE PROTECTION FENCING:
· STORAGE OF CONSTRUCTION MATERIALS, DEBRIS, OR EXCAVATION MATERIAL
· MOVING OR PARKING VEHICLES, HEAVY MACHINERY OR EQUIPMENT
· CONCENTRATED FOOT TRAFFIC
· ERECTION OF SHEDS OR STRUCTURES
· IMPOUNDMENT OF WATER
· EXCAVATION OR DIGGING UNLESS WITHIN THE FOOTPRINT OF PROPOSED SITE HARDSCAPE ELEMENTS
· ATTACHMENT OF SIGNS TO OR WRAPPING MATERIALS AROUND TREES UNLESS OTHERWISE DIRECTED
3. ALL TREES ARE TO REMAIN UNLESS OTHERWISE NOTED. EXTREME CAUTION AND CARE IS TO BE TAKEN WHEN PERFORMING SELECTIVE TREE
REMOVAL AND WHEN INSTALLING PROPOSED IMPROVEMENTS AROUND TREES TO REMAIN.
4. CONTRACTOR SHALL PERFORM SELECTIVE TREE REMOVAL BY REMOVING ONLY TREES WHICH HAVE BEEN DESIGNATED PER THE PLANS.
CONTRACTOR IS TO USE EXTREME CAUTION WITH MINIMAL ASSISTANCE FROM MACHINERY EQUIPMENT IN ORDER TO PREVENT DAMAGE TO
EXISTING TREES TO REMAIN.
5. UNDER TREE CANOPY OF EXISTING TREES TO REMAIN, CONTRACTOR SHALL CUT TREE TRUNKS TO LEVEL OF EXISTING GRADE AND LEAVE ROOTS IN PLACE TO AVOID DAMAGE TO ROOT SYSTEMS OF AN ADJACENT TREE. WHEN TREE STUMP IS LOCATED WITHIN PROPOSED HARDSCAPE FOOTPRINT, CONTRACTOR SHALL COMPLETELY REMOVE STUMP AND ROOTS WHICH PROTRUDE THROUGH THE GROUND SURFACE TO A MINIMUM
DEPTH OF 8" WITHIN THE EXTENTS OF THE PROPOSED HARDSCAPE ELEMENT.
6. ANY PROTECTED TREE THAT IS DAMAGED OR REMOVED PRIOR TO CLIENT OR LANDSCAPE ARCHITECT APPROVAL SHALL BE MITIGATED PER THE GOVERNING AGENCIES REQUIREMENTS BY THE CONTRACTOR AT NO ADDITIONAL COST TO THE CLIENT.
FIELD 2
FIELD 3
FIELD 4
FIELD 5
M
AT
C H
LI
N
E 'A
R
E:
A
/T P.
M
AT
C H
LI
N
E 'A
R
E:
A
/T P.
EXISTING TREE TO BE
REMOVED, TYP.
RE: DM.00 SERIES
EXISTING TREE TO BE
REMOVED, TYP.
RE: DM.00 SERIES
EXISTING TREE AND
CANOPY TO REMAIN AND
BE PROTECTED, TYP.
TREE PROTECTION FENCING, TYP.
PER CITY STANDARD DETAILS
RE: TP.03
TREE PROTECTION
FENCING, TYP. PER CITY
STANDARD DETAILS
RE: TP.03
EXISTING UTILITY,
TYP.
EXISTING PEDESTRIAN
LIGHT POLE, TYP.
EXISTING IRRIGATION
BOX, TYP.
EXISTING ELECTRICAL
EQUIPMENT, TYP.
EXISTING SHADE
STRUCTURE
EXISTING PLAYGROUND
EXISTING FIELD LIGHT
POLE, TYP.
EXISTING UTILITY, TYP.
EXISTING IRRIGATION
CONTROL BOX, TYP.
EXISTING FENCE, TYP.
EXISTING FENCE, TYP.
EXISTING DROP INLET
EXISTING IRRIGATION
BOX, TYP.
EXISTING FIELD LIGHT
POLE, TYP.
EXISTING TREE AND
CANOPY TO REMAIN AND
BE PROTECTED, TYP.
EXISTING PEDESTRIAN
LIGHT POLE, TYP
EXISTING SHADE
STRUCTURE
M
AT
C H
LI
N
E 'B
R
E:
B
/T P.
M
AT
C H
LI
N
E 'B
R
E:
A
/T P.
EXISTING DROP INLET
EXISTING TREE TO BE
REMOVED, TYP.
RE: DM.00 SERIES
EXISTING FIELD
LIGHT POLE, TYP.
EXPAND TREE PROTECTION FENCING
AREA AFTER SITE DEMOLITION TO
EDGES OF PROPOSED HARDSCAPE, TYP.
EXPAND TREE PROTECTION FENCING
AREA AFTER SITE DEMOLITION TO
EDGES OF PROPOSED HARDSCAPE, TYP.
APPROXIMATE LOCATION OF
EXISTING STORM LINE
APPROXIMATE LOCATION OF
EXISTING SANITARY SEWER
APPROXIMATE LOCATION OF
EXISTING WATER LINE
REVISIONS
ARCHITECT
PROJECT NUMBER
G R
AD
Y
LI
TT
LE
JO
H N
SO
FT
BA
LL
C O
M
PL
EX
M
C
KI
N N
EY
, T
EX
AS
NTP660-0157F
CLIENT
KEY MAP
LJA
2150 S Central Expressway Suite 300 McKinney, TX 75070
REMARKSDATEREVISION REMARKSDATEREVISION
ISSUE TITLE: ISSUE DATE:
PROJECT DESIGNER:DRAWN BY:
PROJECT MANAGER:
100% CONSTRUCTION
DOCUMENTS
12/17/25
BV
JS, TS JS
PROJECT
SHEET NO.
2150 South Central Expressway | Suite 380 | McKinney, Texas 75070 Phone 214.620.2800 FRN - F-1386
PLANNING | LANDSCAPE ARCHITECTURE
SHEET TITLE
DESIGN TEAM
PROJECT
SHEET NO.
2150 South Central Expressway | Suite 380 | McKinney, Texas 75070 Phone 214.620.2800 FRN - F-1386
PLANNING | LANDSCAPE ARCHITECTURE
SHEET TITLE
DESIGN TEAM
HI
B
C
ST
E C
CT
TE
SA
ET
S
TA
I
RE
G
OF
2 2
ET
X
C R
LDRE
CAANDS EP A
J R
L L
I
VJY
. II
SEAL
DECEMBER 17, 2025
CITY OF MCKINNEY
401 E. VIRGINIA ST.
MCKINNEY, TX 75069
TO
W
N E
LA
KE
DEVELOPMENT PERMIT
2025-00075
TREE PROTECTION
PLAN
(FEET)
1 inch = ft.
2010 40
NORTH TP.02
SCALE:A TREE PROTECTION PLAN
1"= 20' PLAN
GENERAL NOTES
1. THE FOLLOWING PRACTICES SHALL BE FOLLOWED FOR ENTIRE AREA WITHIN TREE PROTECTION FENCE:
· ALL WORK WITHIN 15 FEET OF EXISTING TREE TRUCKS SHALL BE DONE BY HAND.
· WHERE TRENCHING IS REQUIRED, EXCAVATE UNDER OR AROUND TREE ROOTS BY HAND OR WITH AIR SPADE, OR TUNNEL UNDER ROOTS
BY HORIZONTAL AUGER BORING. DO NOT CUT MAIN LATERAL TREE ROOTS OR TAPROOTS. ONLY CUT ROOTS LESS THAN 1/2" DIA. WHICH
INTERFERE WITH INSTALLATION OF UTILITIES.
· ALL ROOTS 2" OR LARGER IN CALIPER THAT ARE CUT WITHIN HARDSCAPE PATH FOOTPRINT SHALL BE CUT OFF SQUARE.
· DO NOT ALLOW EXPOSED ROOTS TO DRY OUT BEFORE PLACING PERMANENT BACKFILL.
· DO NOT DIRECT VEHICLE OR EQUIPMENT EXHAUST TOWARD PROTECTION ZONES.
· PROHIBIT HEAT SOURCES, FLAMES, IGNITION SOURCES, AND SMOKING WITHIN OR NEAR TREE PROTECTION ZONES.
2. THE FOLLOWING PRACTICES ARE PROHIBITED WITHIN TREE PROTECTION FENCING:
· STORAGE OF CONSTRUCTION MATERIALS, DEBRIS, OR EXCAVATION MATERIAL
· MOVING OR PARKING VEHICLES, HEAVY MACHINERY OR EQUIPMENT
· CONCENTRATED FOOT TRAFFIC
· ERECTION OF SHEDS OR STRUCTURES
· IMPOUNDMENT OF WATER
· EXCAVATION OR DIGGING UNLESS WITHIN THE FOOTPRINT OF PROPOSED SITE HARDSCAPE ELEMENTS
· ATTACHMENT OF SIGNS TO OR WRAPPING MATERIALS AROUND TREES UNLESS OTHERWISE DIRECTED
3. ALL TREES ARE TO REMAIN UNLESS OTHERWISE NOTED. EXTREME CAUTION AND CARE IS TO BE TAKEN WHEN PERFORMING SELECTIVE TREE
REMOVAL AND WHEN INSTALLING PROPOSED IMPROVEMENTS AROUND TREES TO REMAIN.
4. CONTRACTOR SHALL PERFORM SELECTIVE TREE REMOVAL BY REMOVING ONLY TREES WHICH HAVE BEEN DESIGNATED PER THE PLANS.
CONTRACTOR IS TO USE EXTREME CAUTION WITH MINIMAL ASSISTANCE FROM MACHINERY EQUIPMENT IN ORDER TO PREVENT DAMAGE TO
EXISTING TREES TO REMAIN.
5. UNDER TREE CANOPY OF EXISTING TREES TO REMAIN, CONTRACTOR SHALL CUT TREE TRUNKS TO LEVEL OF EXISTING GRADE AND LEAVE ROOTS IN PLACE TO AVOID DAMAGE TO ROOT SYSTEMS OF AN ADJACENT TREE. WHEN TREE STUMP IS LOCATED WITHIN PROPOSED HARDSCAPE FOOTPRINT, CONTRACTOR SHALL COMPLETELY REMOVE STUMP AND ROOTS WHICH PROTRUDE THROUGH THE GROUND SURFACE TO A MINIMUM
DEPTH OF 8" WITHIN THE EXTENTS OF THE PROPOSED HARDSCAPE ELEMENT.
6. ANY PROTECTED TREE THAT IS DAMAGED OR REMOVED PRIOR TO CLIENT OR LANDSCAPE ARCHITECT APPROVAL SHALL BE MITIGATED PER THE GOVERNING AGENCIES REQUIREMENTS BY THE CONTRACTOR AT NO ADDITIONAL COST TO THE CLIENT.
TREE PROTECTION LEGEND
SYMBOL DESCRIPTION SYMBOL DESCRIPTION
EXISTING TREE TO REMAIN
AND BE PROTECTED EXISTING CONTOUR
EXISTING TREE CANOPY EXISTING LIGHT POLE
TREE PROTECTION
FENCING
RE: TP.03
EXISTING TREE TO BE
REMOVED
RE: DM.01 - DM.02
REVISIONS
ARCHITECT
PROJECT NUMBER
G R
AD
Y
LI
TT
LE
JO
H N
SO
FT
BA
LL
C O
M
PL
EX
M
C
KI
N N
EY
, T
EX
AS
NTP660-0157F
CLIENT
KEY MAP
LJA
2150 S Central Expressway Suite 300 McKinney, TX 75070
REMARKSDATEREVISION REMARKSDATEREVISION
ISSUE TITLE: ISSUE DATE:
PROJECT DESIGNER:DRAWN BY:
PROJECT MANAGER:
100% CONSTRUCTION
DOCUMENTS
09/08/25
BV
JS, TS JS
PROJECT
SHEET NO.
2150 South Central Expressway | Suite 380 | McKinney, Texas 75070 Phone 214.620.2800 FRN - F-1386
PLANNING | LANDSCAPE ARCHITECTURE
SHEET TITLE
DESIGN TEAM
PROJECT
SHEET NO.
2150 South Central Expressway | Suite 380 | McKinney, Texas 75070 Phone 214.620.2800 FRN - F-1386
PLANNING | LANDSCAPE ARCHITECTURE
SHEET TITLE
DESIGN TEAM
HI
B
C
ST
E C
CT
TE
SA
ET
S
TA
I
RE
G
OF
2 2
ET
X
C R
LDRE
CAANDS EP A
J R
L L
I
VJY
. II
SEAL
SEPTEMBER 8, 2025
CITY OF MCKINNEY
401 E. VIRGINIA ST.
MCKINNEY, TX 75069
TO
W
N E
LA
KE
DEVELOPMENT PERMIT
2025-00075
TREE PRESERVATION
CHART
TP.03
City of McKinney - Tree Preservation Ian Erickson - ISA Certified Arborist
Urban Forester ierickson@mckinneytexas.org
(972)547-9014 Tree Preservation
Approved 09/10/2025
FIELD 1
FIELD 6
EXISTING FIELD LIGHT
POLE, TYP.
EXISTING FENCE, TYP.
EXISTING FIELD LIGHT
POLE, TYP.
EXISTING FENCE, TYP.
EXISTING IRRIGATION
BOX, TYP.
CONTRACTOR TO PROVIDE AND MAINTAIN
CONCRETE WASHOUT FACILITY THROUGHOUT
CONSTRUCTION PER CITY OF MCKINNEY
STANDARD DETAIL
RE: 1080M/SP.04
6'-0" TALL CHAIN LINK
TEMPORARY FENCING W/ GATED
CONSTRUCTION ENTRANCE
STABILIZED CONSTRUCTION ACCESS PER
CITY OF MCKINNEY STANDARD DETAIL
RE: 1070M/SP.04
CONSTRUCTION STAGING
ZONE; COORDINATE EXACT
LOCATION WITH OWNER
EXISTING IRRIGATION
BOX, TYP.
CONSTRUCTION STAGING
ZONE; COORDINATE EXACT
LOCATION WITH OWNER
SILT FENCING PER CITY
STANDARD DETAILS
RE: SP.04
EXISTING CONCRETE
SIDEWALK, TYP.
EXISTING IRRIGATION
BOX, TYP.
EXISTING CONCRETE
SIDEWALK, TYP.
M
AT
C H
LI
N
E 'A
R
E:
A
/S P.
M
AT
C H
LI
N
E 'A
R
E:
A
/S P.
6'-0" TALL CHAIN LINK
TEMPORARY FENCING
SILT FENCING PER CITY
STANDARD DETAILS
RE: SP.04
SILT FENCING PER CITY
STANDARD DETAILS
RE: SP.04
SILT FENCING PER CITY
STANDARD DETAILS
RE: SP.04
APPROXIMATE LOCATION OF
EXISTING SANITARY SEWER
APPROXIMATE LOCATION OF
EXISTING WATER LINE
'-0
50'-0"
54854
7FIELD 3
FIELD 4
EXISTING FIELD LIGHT
POLE, TYP.
EXISTING FENCE, TYP.
EXISTING BOLLARDS,
TYP.
SILT FENCING PER CITY
STANDARD DETAILS
RE: SP.04
LI
M
IT
O
F W
O R
K
M
AT
C H
LI
N
E 'B
R
E:
B
/S P.
M
AT
C H
LI
N
E 'B
R
E:
A
/S P.
R E:
D O
G P
AR
K
PL
AN
S
REVISIONS
ARCHITECT
PROJECT NUMBER
G R
AD
Y
LI
TT
LE
JO
H N
SO
FT
BA
LL
C O
M
PL
EX
M
C
KI
N N
EY
, T
EX
AS
NTP660-0157F
CLIENT
KEY MAP
LJA
2150 S Central Expressway Suite 300 McKinney, TX 75070
REMARKSDATEREVISION REMARKSDATEREVISION
ISSUE TITLE: ISSUE DATE:
PROJECT DESIGNER:DRAWN BY:
PROJECT MANAGER:
100% CONSTRUCTION
DOCUMENTS
12/17/25
BV
JS, TS JS
PROJECT
SHEET NO.
2150 South Central Expressway | Suite 380 | McKinney, Texas 75070 Phone 214.620.2800 FRN - F-1386
PLANNING | LANDSCAPE ARCHITECTURE
SHEET TITLE
DESIGN TEAM
PROJECT
SHEET NO.
2150 South Central Expressway | Suite 380 | McKinney, Texas 75070 Phone 214.620.2800 FRN - F-1386
PLANNING | LANDSCAPE ARCHITECTURE
SHEET TITLE
DESIGN TEAM
HI
B
C
ST
E C
CT
TE
SA
ET
S
TA
I
RE
G
OF
2 2
ET
X
C R
LDRE
CAANDS EP A
J R
L L
I
VJY
. II
SEAL
DECEMBER 17, 2025
CITY OF MCKINNEY
401 E. VIRGINIA ST.
MCKINNEY, TX 75069
TO
W
N E
LA
KE
DEVELOPMENT PERMIT
2025-00075
SITE PREPARATION
& EROSION
CONTROL PLAN
(FEET)
1 inch = ft.
2010 40
SCALE:A
SITE PREPARATION &
EROSION CONTROL PLAN
1"= 20' PLAN
NORTH SP.01
SCALE:B
SITE PREPARATION &
EROSION CONTROL PLAN
1"= 20' PLAN (FEET)
1 inch = ft.
2010 40
NORTH
SITE PREPARATION LEGEND
SYMBOL DESCRIPTION SYMBOL DESCRIPTION
EXISTING TREE TO REMAIN EXISTING CONTOUR
EXISTING TREE CANOPY EXISTING LIGHT POLE
TO REMAIN
SILT FENCE
RE: SP.04
TEMPORARY
CONSTRUCTION FENCE
RE: SP.04
TREE PROTECTION
FENCING
RE: TP.03
GENERAL NOTES
1. CONTRACTOR TO FIELD VERIFY ALL UTILITIES PRIOR TO CONSTRUCTION.
2. CONTRACTOR TO OBTAIN ALL REQUIRED SWPPP PERMITS PRIOR TO CONSTRUCTION.
3. ALL STORMWATER CONTROL MEASURES (SCM) MUST BE DESIGNED, INSTALLED, AND MAINTAINED TO RETAIN SEDIMENT ON-SITE
TO THE EXTENT PRACTICAL.
4. THE CONTRACTOR IS RESPONSIBLE FOR MAINTAINING SCMs THROUGHOUT CONSTRUCTION ON A DAILY BASIS. CONTRACTOR
MUST REMOVE SEDIMENT FROM ALL APPLICABLE CONTROLS WHEN DESIGN SILT STORAGE CAPACITY HAS BEEN REDUCED BY 50%. WHEN INSPECTIONS IDENTIFY CONTROLS OPERATING INEFFECTIVELY, THE CONTROLS SHALL BE MAINTAINED AT MINIMIUM BIWEEKLY AND BEFORE, DURING, AFTER A RAIN EVENT. EACH INSPECTION SHALL BE KEPT IN A LOG.
5. ADDITIONAL EROSION CONTROL MEASURES MAY BE REQUIRED DUE TO UNFORESEEN PROBLEMS OR IF THE CONTRACTOR'S PLAN DOES NOT FUNCTION AS INTENDED. A REPRESENTATIVE OF THE ARCHITECT, CITY OR STATE MAY REQUIRE ADDITIONAL CONTROL DEVICES UPON INSPECTION OF FACILITIES. ADDITIONAL MEASURES, IF REQUIRED, SHALL BE INSTALLED AT NO
ADDITIONAL COST TO THE OWNER.
6. CONTRACTOR SHALL MONITOR OFF-SITE ACCUMULATIONS OF SEDIMENT ESCAPING THE PROJECT SITE AND REMOVE ACCUMULATED SEDIMENT IMMEDIATELY. SEDIMENTATION WITHIN STREETS OR PARKING LOT ADJACENT TO THE PROJECT SITE MUST BE REMOVED PRIOR TO RAINFALL EVENTS. CONTRACTOR SHALL BE RESPONSIBLE FOR THE PAYMENT OF ALL FINES FOR
VIOLATIONS REGARDING EROSION CONTROL.
7. CONTRACTOR SHALL ENSURE THAT ALL LITTER, CONSTRUCTION DEBRIS, AND CONSTRUCTION CHEMICALS ARE PREVENTED
FROM BECOMING POLLUTANT SOURCES.
8. OFF-SITE MATERIAL STORAGE AREAS USED SOLELY FOR THIS PROJECT, INCLUDING FILL STOCKPILES AND BORROW AREAS (AS APPLICABLE), MUST BE PREVENTED FROM BECOMING POLLUTANT SOURCES BY INSTALLATION OF BMP'S.
9. CONTRACTOR SHALL INSPECT ACCESSIBLE DISCHARGE LOCATIONS IN ORDER TO VERIFY THAT EROSION CONTROL MEASURES ARE EFFECTIVE IN PREVENTING SIGNIFICANT IMPACTS TO THE RECEIVING DRAINAGE SYSTEM.
10. CONTRACTOR SHALL IDENTIFY ALL SOURCES OF ALLOWABLE NON-STORM WATER THAT WILL BE COMBINED WITH STORM WATER AT THE SITE AND ENSURE IMPLEMENTATION OF APPROPRIATE POLLUTION PREVENTION MEASURES FOR NON-STORM WATER
COMPONENTS OF DISCHARGE.
11. AT THE END OF CONSTRUCTION, CONTRACTOR SHALL REMOVE SCMs IN ADDITION TO ALL SEDIMENT AND TRASH THAT MAY HAVE
BEEN DEPOSITED IN NEW AND EXISTING PIPES, STRUCTURES, AND BMPS.
CITY REQUIRED EROSION CONTROL NOTES
TEMPORARY CONTROLS:
· SEDIMENTATION BASINS REQUIRED FOR DRAINAGE AREAS 10 ACRES OR MORE.
· TEMPORARY CONTROLS MUST INCLUDE METHODS TO REDUCE DUST FROM THE
CONSTRUCTION SITE. THIS MAY INCLUDE WETTING HAUL ROADS OR AREAS OF
EXCAVATION PRIOR TO BEGINNING WORK.
· TWO LAYERS OF SILT FENCE SHALL BE INSTALLED ADJACENT TO FLOODPLAIN AREAS.
· ALL EROSION CONTROL BMPS ARE TO BE ROUTINELY INSPECTED AND REPAIRED AS
NECESSARY THROUGHOUT THE DURATION OF CONSTRUCTION.
FINAL STABILIZATION:
· CONTRACTOR TO RE-STABILIZE AND RE-VEGETATE ALL DISTURBED AREAS PRIOR TO
FINAL ACCEPTANCE. FINAL STABILIZATION THROUGH VEGETATION WILL REQUIRE
100% COVERAGE AT 70% DENSITY.
· CONTRACTOR TO INSTALL CURLEX EROSION MATTING OR APPROVED EQUIVALENT
ON ALL AREAS OF 10H:1V SLOPE OR GREATER.
· FOR AREAS WITH NO SIDEWALK, SOD SHALL BE PLACED TO COVER THE FIRST FOUR
FEET BEHIND THE CURB OR THE ENTIRE AREA FROM THE CURB TO THE
RIGHT-OF-WAY LINE, WHICHEVER IS SMALLER.
· FOR AREAS WHERE THE SIDEWALK IS NOT AT THE BACK OF CURB, SOD SHALL BE
PLACED TO COVER THE FIRST 4 FEET BEHIND THE CURB OR THE ENTIRE AREA
BETWEEN THE CURB AND THE SIDEWALK, WHICHEVER IS GREATER. SOD SHALL ALSO
BE PLACED TO COVER THE FIRST 2 FEET BEHIND THE BACK OF SIDEWALK OR THE
ENTIRE AREA FROM THE BACK OF SIDEWALK TO THE RIGHT-OF-WAY LINE.
· FOR AREAS WHERE THE SIDEWALK IS AT THE BACK OF CURB, SOD SHALL BE PLACED
TO COVER THE FIRST FOUR FEET ADJACENT TO THE SIDEWALK OR THE ENTIRE AREA
FROM THE SIDEWALK TO THE RIGHT-OF-WAY LINE.
· SOD SHALL BE PLACED TO COVER THE FIRST FOUR FEET BEHIND THE CURB OF ALL
MEDIAN AREAS.
RELEASED FOR CONSTRUCTION
CITY OF McKINNEY ENGINEERING DEPARTMENT
January 27, 2026 by Jennifer Jackson, P.E.
Prior to commencing construction, the owner or their representative shall hold a Pre-Construction Conference with and be issued a Development Permit by the City of McKinney Engineering Department. A copy of the Development
Permit and these stamped construction drawings shall be maintained on the construction site at all times. If a conflict is found between these construction drawings and the City of McKinney Construction Standards, the City of
X:\Development Services\EngineeringFiles\DEV\2025\DEV2025-00075 Grady Littlejohn Redevelopment\2026-01-27 DWGS(DEV2025-00075)(Grady LittleJohn Redevelopment).pdf 01/27/2026 4:18:10 PM Jennifer Jackson, P.E.
FIELD 2
FIELD 3
FIELD 4
FIELD 5
EXISTING TREE CANOPY
EXISTING PEDESTRIAN
LIGHT POLE
EXISTING TREE
CANOPY
TREE PROTECTION
FENCING, TYP.
TREE PROTECTION
FENCING, TYP.
EXISTING UTILITY,
TYP.
EXISTING PEDESTRIAN
LIGHT POLE
EXISTING IRRIGATION
BOX, TYP.
EXISTING ELECTRICAL
EQUIPMENT
EXISTING SHADE
STRUCTURE
EXISTING SHADE
STRUCTURE
EXISTING PLAYGROUND,
EWF SURFACING, AND
SUBSURFACE DRAINAGE
EXISTING FIELD LIGHT
POLE, TYP.
EXISTING UTILITY, TYP.
EXISTING IRRIGATION
CONTROL BOX, TYP.
EXISTING FENCE, TYP.
EXISTING FIELD LIGHT
POLE, TYP.
EXISTING FENCE, TYP.
EXISTING DROP INLET
EXISTING BOLLARD
M
AT
C H
LI
N
E 'A
R
E:
A
/S P.
M
AT
C H
LI
N
E 'A
R
E:
A
/S P.
M
AT
C H
LI
N
E 'B
R
E:
B
/S P.
M
AT
C H
LI
N
E 'B
R
E:
A
/S P.
SILT FENCING PER CITY
STANDARD DETAILS
RE: SP.04
SILT FENCING PER CITY
STANDARD DETAILS
RE: SP.04
SILT FENCING PER CITY
STANDARD DETAILS
RE: SP.04
SILT FENCING PER CITY
STANDARD DETAILS
RE: SP.04
SILT FENCING PER CITY
STANDARD DETAILS
RE: SP.04
PROTECT EXISTING EWF AND
PLAYGROUND SUBSURFACE
DRAINAGE FROM SEDIMENT
INFILTRATION
DROP INLET PROTECTION
PER CITY STANDARD DETAILS
RE: SP.04
EXISTING DROP INLET
DROP INLET PROTECTION
PER CITY STANDARD DETAILS
RE: SP.04 APPROXIMATE LOCATION OF
EXISTING STORM LINE
APPROXIMATE LOCATION OF
EXISTING SANITARY SEWER
APPROXIMATE LOCATION
OF EXISTING WATER LINE
M
AT
C H
LI
N
E 'B
R
E:
A
/S P.
M
AT
C H
LI
N
E 'B
R
E:
A
/S P.
MATCHLINE 'B' (RE: A/SP.02)
MATCHLINE 'B' (RE: A/SP.03)
EXISTING FIELD LIGHT
POLE, TYP.
APPROXIMATE LOCATION
OF EXISTING WATER LINE
SILT FENCING PER CITY
STANDARD DETAILS
RE: SP.03
REVISIONS
ARCHITECT
PROJECT NUMBER
G R
AD
Y
LI
TT
LE
JO
H N
SO
FT
BA
LL
C O
M
PL
EX
M
C
KI
N N
EY
, T
EX
AS
NTP660-0157F
CLIENT
KEY MAP
LJA
2150 S Central Expressway Suite 300 McKinney, TX 75070
REMARKSDATEREVISION REMARKSDATEREVISION
ISSUE TITLE: ISSUE DATE:
PROJECT DESIGNER:DRAWN BY:
PROJECT MANAGER:
100% CONSTRUCTION
DOCUMENTS
12/17/25
BV
JS, TS JS
PROJECT
SHEET NO.
2150 South Central Expressway | Suite 380 | McKinney, Texas 75070 Phone 214.620.2800 FRN - F-1386
PLANNING | LANDSCAPE ARCHITECTURE
SHEET TITLE
DESIGN TEAM
PROJECT
SHEET NO.
2150 South Central Expressway | Suite 380 | McKinney, Texas 75070 Phone 214.620.2800 FRN - F-1386
PLANNING | LANDSCAPE ARCHITECTURE
SHEET TITLE
DESIGN TEAM
HI
B
C
ST
E C
CT
TE
SA
ET
S
TA
I
RE
G
OF
2 2
ET
X
C R
LDRE
CAANDS EP A
J R
L L
I
VJY
. II
SEAL
DECEMBER 17, 2025
CITY OF MCKINNEY
401 E. VIRGINIA ST.
MCKINNEY, TX 75069
TO
W
N E
LA
KE
DEVELOPMENT PERMIT
2025-00075
(FEET)
1 inch = ft.
2010 40
NORTH SP.02
SCALE:A
SITE PREPARATION &
EROSION CONTROL PLAN
1"= 20' PLAN
SITE PREPARATION LEGEND
SYMBOL DESCRIPTION SYMBOL DESCRIPTION
EXISTING TREE TO REMAIN EXISTING CONTOUR
EXISTING TREE CANOPY EXISTING LIGHT POLE
TO REMAIN
SILT FENCE
RE: SP.04
TEMPORARY
CONSTRUCTION FENCE
RE: SP.04
TREE PROTECTION
FENCING
RE: TP.03
SITE PREPARATION
& EROSION
CONTROL PLAN
GENERAL NOTES
1. CONTRACTOR TO FIELD VERIFY ALL UTILITIES PRIOR TO CONSTRUCTION.
2. CONTRACTOR TO OBTAIN ALL REQUIRED SWPPP PERMITS PRIOR TO CONSTRUCTION.
3. ALL STORMWATER CONTROL MEASURES (SCM) MUST BE DESIGNED, INSTALLED, AND MAINTAINED TO RETAIN SEDIMENT ON-SITE
TO THE EXTENT PRACTICAL.
4. THE CONTRACTOR IS RESPONSIBLE FOR MAINTAINING SCMs THROUGHOUT CONSTRUCTION ON A DAILY BASIS. CONTRACTOR
MUST REMOVE SEDIMENT FROM ALL APPLICABLE CONTROLS WHEN DESIGN SILT STORAGE CAPACITY HAS BEEN REDUCED BY 50%. WHEN INSPECTIONS IDENTIFY CONTROLS OPERATING INEFFECTIVELY, THE CONTROLS SHALL BE MAINTAINED AT MINIMIUM BIWEEKLY AND BEFORE, DURING, AFTER A RAIN EVENT. EACH INSPECTION SHALL BE KEPT IN A LOG.
5. ADDITIONAL EROSION CONTROL MEASURES MAY BE REQUIRED DUE TO UNFORESEEN PROBLEMS OR IF THE CONTRACTOR'S PLAN DOES NOT FUNCTION AS INTENDED. A REPRESENTATIVE OF THE ARCHITECT, CITY OR STATE MAY REQUIRE ADDITIONAL CONTROL DEVICES UPON INSPECTION OF FACILITIES. ADDITIONAL MEASURES, IF REQUIRED, SHALL BE INSTALLED AT NO
ADDITIONAL COST TO THE OWNER.
6. CONTRACTOR SHALL MONITOR OFF-SITE ACCUMULATIONS OF SEDIMENT ESCAPING THE PROJECT SITE AND REMOVE ACCUMULATED SEDIMENT IMMEDIATELY. SEDIMENTATION WITHIN STREETS OR PARKING LOT ADJACENT TO THE PROJECT SITE MUST BE REMOVED PRIOR TO RAINFALL EVENTS. CONTRACTOR SHALL BE RESPONSIBLE FOR THE PAYMENT OF ALL FINES FOR
VIOLATIONS REGARDING EROSION CONTROL.
7. CONTRACTOR SHALL ENSURE THAT ALL LITTER, CONSTRUCTION DEBRIS, AND CONSTRUCTION CHEMICALS ARE PREVENTED
FROM BECOMING POLLUTANT SOURCES.
8. OFF-SITE MATERIAL STORAGE AREAS USED SOLELY FOR THIS PROJECT, INCLUDING FILL STOCKPILES AND BORROW AREAS (AS APPLICABLE), MUST BE PREVENTED FROM BECOMING POLLUTANT SOURCES BY INSTALLATION OF BMP'S.
9. CONTRACTOR SHALL INSPECT ACCESSIBLE DISCHARGE LOCATIONS IN ORDER TO VERIFY THAT EROSION CONTROL MEASURES ARE EFFECTIVE IN PREVENTING SIGNIFICANT IMPACTS TO THE RECEIVING DRAINAGE SYSTEM.
10. CONTRACTOR SHALL IDENTIFY ALL SOURCES OF ALLOWABLE NON-STORM WATER THAT WILL BE COMBINED WITH STORM WATER AT THE SITE AND ENSURE IMPLEMENTATION OF APPROPRIATE POLLUTION PREVENTION MEASURES FOR NON-STORM WATER
COMPONENTS OF DISCHARGE.
11. AT THE END OF CONSTRUCTION, CONTRACTOR SHALL REMOVE SCMs IN ADDITION TO ALL SEDIMENT AND TRASH THAT MAY HAVE
BEEN DEPOSITED IN NEW AND EXISTING PIPES, STRUCTURES, AND BMPS.
CITY REQUIRED EROSION CONTROL NOTES
TEMPORARY CONTROLS:
· SEDIMENTATION BASINS REQUIRED FOR DRAINAGE AREAS 10 ACRES OR MORE.
· TEMPORARY CONTROLS MUST INCLUDE METHODS TO REDUCE DUST FROM THE
CONSTRUCTION SITE. THIS MAY INCLUDE WETTING HAUL ROADS OR AREAS OF
EXCAVATION PRIOR TO BEGINNING WORK.
· TWO LAYERS OF SILT FENCE SHALL BE INSTALLED ADJACENT TO FLOODPLAIN AREAS.
· ALL EROSION CONTROL BMPS ARE TO BE ROUTINELY INSPECTED AND REPAIRED AS
NECESSARY THROUGHOUT THE DURATION OF CONSTRUCTION.
FINAL STABILIZATION:
· CONTRACTOR TO RE-STABILIZE AND RE-VEGETATE ALL DISTURBED AREAS PRIOR TO
FINAL ACCEPTANCE. FINAL STABILIZATION THROUGH VEGETATION WILL REQUIRE
100% COVERAGE AT 70% DENSITY.
· CONTRACTOR TO INSTALL CURLEX EROSION MATTING OR APPROVED EQUIVALENT
ON ALL AREAS OF 10H:1V SLOPE OR GREATER.
· FOR AREAS WITH NO SIDEWALK, SOD SHALL BE PLACED TO COVER THE FIRST FOUR
FEET BEHIND THE CURB OR THE ENTIRE AREA FROM THE CURB TO THE
RIGHT-OF-WAY LINE, WHICHEVER IS SMALLER.
· FOR AREAS WHERE THE SIDEWALK IS NOT AT THE BACK OF CURB, SOD SHALL BE
PLACED TO COVER THE FIRST 4 FEET BEHIND THE CURB OR THE ENTIRE AREA
BETWEEN THE CURB AND THE SIDEWALK, WHICHEVER IS GREATER. SOD SHALL ALSO
BE PLACED TO COVER THE FIRST 2 FEET BEHIND THE BACK OF SIDEWALK OR THE
ENTIRE AREA FROM THE BACK OF SIDEWALK TO THE RIGHT-OF-WAY LINE.
· FOR AREAS WHERE THE SIDEWALK IS AT THE BACK OF CURB, SOD SHALL BE PLACED
TO COVER THE FIRST FOUR FEET ADJACENT TO THE SIDEWALK OR THE ENTIRE AREA
FROM THE SIDEWALK TO THE RIGHT-OF-WAY LINE.
· SOD SHALL BE PLACED TO COVER THE FIRST FOUR FEET BEHIND THE CURB OF ALL
MEDIAN AREAS.
RELEASED FOR CONSTRUCTION
CITY OF McKINNEY ENGINEERING DEPARTMENT
January 27, 2026 by Jennifer Jackson, P.E.
Prior to commencing construction, the owner or their representative shall hold a Pre-Construction Conference with and be issued a Development Permit by the City of McKinney Engineering Department. A copy of the Development
Permit and these stamped construction drawings shall be maintained on the construction site at all times.