This document contains a floor plan drawing for a proposed Fisher House and related federal contract opportunity notice. The floor plan depicts the layout and dimensions of rooms, doors, windows, and other features for a two-story building. The federal contract opportunity is a solicitation from the Department of Veterans Affairs for design/build construction services for site utilities to support the Fisher House. Services required include design, permitting, and construction of all site utilities outside of the building footprint, such as water, sewer, gas, and electrical connections and associated site work. The solicitation number is 36C24720R0050 and responses are due by the date specified on FBO.gov. The award is to be a firm-fixed-price contract.

View the file

Other files

File Type Posted
SC20200028 01-03-2020.docx DOCX document
PAST PERFORMANCE QUESTIONNAIRE.rtf RTF text file
Siteplan.pdf PDF
A3 elevation.pdf PDF
FH-COLUMBIA-SCRENDERING.jpg JPG image
36C24720R0050_1.docx DOCX document
6elevation.pdf PDF
3A1Floorplan.pdf PDF
FH Qualifaction SIte Plan.docx DOCX document

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

LINEN CLOSET

ACCESS

ATTIC

HALL

BEDROOM206

BEDROOM

BEDROOM

BEDROOM

BEDROOM

BEDROOM

BEDROOM

BEDROOM

BATH

200b

HALL

200a

HALL

CLO.

CLO.

D

# 5 # 43

D

# 5 # 46

# 49

D

# 5 # 54

D

# 5 # 63

D

# 5 # 61

D

# 5 #70

D

# 5 # 58

# 51 C1

# 45

# 44

# 53

# 56

# 68

# 64 # 60

# 7

G # 42 # 7

G # 47

# 7

F # 50

# 7

F # 69

# 7

F # 55

# 7

G # 59

#67

# 7

G # 62

# 7

G # 57

DN

# 65

D

# 5 # 52

A-5 B

A-5 B

A-5 A

A-5 A

16 17 18

22232425

E

E

E

F

F

F

E

C

LO

S

C

LO

S

C

LO

S

C

LO

S

C

LO

S .C

LO

S

CLOS.

F

F

E

E

E

MIN.

MIN.

M

IN

BATH

BATH

BATH

BATH

BATH

BATH

BATH

NOTE: PROVIDE WATERPROOFING AT ALL BATHROOMS

ON 2ND FLOOR, SHEET TYPE WATERPROOFING

SYSTEM BY "GRACE" OR APPROVED EQUAL

FD

FD

FD FD

FD

FD FD

FD

B

B

DN B

HS

F

HS

HS

F

F

B

B

B

B

B

FIRE

STAIR

"B"

FIRE

STAIR

"A"

C1

C1

C1

C1C1

C1 C1

C1

C5

C5

#3a # 66 C1

#3a

#3a #3a

#3a #3a

#3a #3a

#3a

#4a

#4a

#3a

8'-8" 13'-2 1/2" 8'-3" 13'-2 1/2" 8'-8"

52'-0"

'-4

'-8

/2

'-7

'-9

/2

'-1

'-8

'-2

'-7

/2

'-7

'-3

/2

'-6

'-1

'-8

'-3

'-0

/2

'-4

/2

'-7

'-0

/2

'-4

/2

'-7

'-0

'-1

/2

8'-8" 17'-4" 17'-4" 8'-8"

F.E.C

F.E.C

5'-8"

2X4 WALL

FOR SHOWER

STALL

A-6 C

A-6 C

FIRE

STAIR

CLOSET

FIRE

STAIR

A

A

G

G

G F E

G

G

B

B

BF

E

B

E

E

E

E

E

E

E E

E

E E

E

C

C

C

C

E

EE

E

F

E

F

EEE

E

E E

E

E E E

F

5'-8"

63'-4"

'-0

BEARING WALLS AND PARTITIONS

SEE PLANS AND SECTIONS

DOOR DETAILS

Door types # Door # Hardware set #

CMU WALL 8" THICK/ 2HR FIRE RATED

SECTION

Section. # Sheet #

ELEVATION

Elev. # Sheet #

# 4

C # 4

A-# F

F A-#

LEGEND

WINDOW #22

F

S

HS

F.E.

F.A SPEAKER/ STROBE

(WALL MTD. 80"AFF)

F.A MANUAL PULL STATION

F.A VISUAL STROBE DEVICE

(WALL MTD. 80" AFF)

WALL HUNG

FIRE EXTINGUISHER

RECESSED

FIRE EXTINGUISHER + CAB

DOOR HOLD OPEN DEVICE

REQUIRES POWER FEED

AND INTERCONNECT TO

FIRE ALARM SYSTEM

DH

FLOOR DRAINFD

2HR FIRE RATED PARTITIONS

XXXX PLAQUE

MOUNTING 64"AFF

B PARTITION TYPE

SEE DWG A-6

FIRE CURTAIN

SEE DWG A-10.1FOR DETAILS

NOTE : GC TO COORDINATE - ELECTRICAL

CONTRACTOR TO PROVIDE REQUIRED

CONNECTION TO FIRE ALARM SYSTEM

FC

FACP SEMI-RECESSED

FIRE ALARM CONTROL PANEL

RECESSED

REMOTE ANNUNCIATORANN

F.E.C

SECOND FLOOR PLAN

A - 2

A R

C H

IT

E

C T

S

D E

S

IG

N E

R S

D E

S

IG

N T

E C

H A

S S

O C

IA

T

E S

B R

O A

D W

A Y

, N E

W Y

O R

K , N

Y

Foundation, Inc.

Fisher House

Draper Aden Associates Engineering Surveying Environmental Services phone 804.264.2228 / fax 804.264.8773 / mobile 804.937.6717 www.daa.com

A R C H I T E C T S + D E S I G N E R S

D E S I G N T E C H A S S O C I A T E S

PROPOSED FISHER HOUSE

VAMC COLUMBIA-SC

7 7 N o r t h C e n t r e A v e n u e S u i t e 3 1 5

R o c k v i l l e C e n t r e , N e w Y o r k 1 1 5 7 0

2 1 2 - 9 4 4 - 7 7 7 0 F a x 2 1 2 - 9 4 4 - 7 8 0 3

AutoCAD SHX Text 1/4"=1'-0"

AutoCAD SHX Text

DRAWING

AutoCAD SHX Text

SCALE

AutoCAD SHX Text

DATE

AutoCAD SHX Text DRAWING No.

AutoCAD SHX Text

(858) 679-8989 Fax (858) 679-8959

AutoCAD SHX Text Poway, CA 92064-8819

AutoCAD SHX Text 14288 Danielson Street

AutoCAD SHX Text S T R U C T U R A L E N G I N E E R S

AutoCAD SHX Text

KUSHKAKI

AutoCAD SHX Text

TAYLOR

AutoCAD SHX Text

HOROWITZ

AutoCAD SHX Text Suite #200

AutoCAD SHX Text A

AutoCAD SHX Text One Liberty Plaza 165 Broadway, 22nd Floor New York, NY 10006 T: 212.354.5656 F: 212.354.5668

AutoCAD SHX Text K

AutoCAD SHX Text F

AutoCAD SHX Text ARLINGTON / BOSTON / MEXICO CITY / MINNEAPOLIS / NEW YORK / BOSTON / MEXICO CITY / MINNEAPOLIS / NEW YORK BOSTON / MEXICO CITY / MINNEAPOLIS / NEW YORK / MEXICO CITY / MINNEAPOLIS / NEW YORK MEXICO CITY / MINNEAPOLIS / NEW YORK / MINNEAPOLIS / NEW YORK MINNEAPOLIS / NEW YORK / NEW YORK NEW YORK PHILADELPHIA / PRINCETON / PUEBLA / ROCHESTER / STAMFORD/ PRINCETON / PUEBLA / ROCHESTER / STAMFORD PRINCETON / PUEBLA / ROCHESTER / STAMFORD/ PUEBLA / ROCHESTER / STAMFORD PUEBLA / ROCHESTER / STAMFORD/ ROCHESTER / STAMFORD ROCHESTER / STAMFORD/ STAMFORD STAMFORD

AutoCAD SHX Text ENGINEERING / ANALYSIS & TESTING / BUILDING MANAGEMENT SYSTEMS / CENTRAL UTILITIES / ANALYSIS & TESTING / BUILDING MANAGEMENT SYSTEMS / CENTRAL UTILITIES / ANALYSIS & TESTING / BUILDING MANAGEMENT SYSTEMS / CENTRAL UTILITIES ANALYSIS & TESTING / BUILDING MANAGEMENT SYSTEMS / CENTRAL UTILITIES ANALYSIS & TESTING / BUILDING MANAGEMENT SYSTEMS / CENTRAL UTILITIES / BUILDING MANAGEMENT SYSTEMS / CENTRAL UTILITIES / BUILDING MANAGEMENT SYSTEMS / CENTRAL UTILITIES BUILDING MANAGEMENT SYSTEMS / CENTRAL UTILITIES BUILDING MANAGEMENT SYSTEMS / CENTRAL UTILITIES / CENTRAL UTILITIES / CENTRAL UTILITIES CENTRAL UTILITIES CENTRAL UTILITIES CODE CONSULTING / COMMISSIONING / CRITICAL SYSTEMS / ENERGY & SUSTAINABILITY / COMMISSIONING / CRITICAL SYSTEMS / ENERGY & SUSTAINABILITY / COMMISSIONING / CRITICAL SYSTEMS / ENERGY & SUSTAINABILITY COMMISSIONING / CRITICAL SYSTEMS / ENERGY & SUSTAINABILITY COMMISSIONING / CRITICAL SYSTEMS / ENERGY & SUSTAINABILITY / CRITICAL SYSTEMS / ENERGY & SUSTAINABILITY / CRITICAL SYSTEMS / ENERGY & SUSTAINABILITY CRITICAL SYSTEMS / ENERGY & SUSTAINABILITY CRITICAL SYSTEMS / ENERGY & SUSTAINABILITY / ENERGY & SUSTAINABILITY / ENERGY & SUSTAINABILITY ENERGY & SUSTAINABILITY ENERGY & SUSTAINABILITY FIRE PROTECTION / IT/AV/SECURITY / LIGHTING DESIGN / SPECIAL INSPECTIONS / IT/AV/SECURITY / LIGHTING DESIGN / SPECIAL INSPECTIONS / IT/AV/SECURITY / LIGHTING DESIGN / SPECIAL INSPECTIONS IT/AV/SECURITY / LIGHTING DESIGN / SPECIAL INSPECTIONS IT/AV/SECURITY / LIGHTING DESIGN / SPECIAL INSPECTIONS / LIGHTING DESIGN / SPECIAL INSPECTIONS / LIGHTING DESIGN / SPECIAL INSPECTIONS LIGHTING DESIGN / SPECIAL INSPECTIONS LIGHTING DESIGN / SPECIAL INSPECTIONS / SPECIAL INSPECTIONS / SPECIAL INSPECTIONS SPECIAL INSPECTIONS SPECIAL INSPECTIONS www.AKFGroup.com

AutoCAD SHX Text

REVISION

AutoCAD SHX Text

DATE

AutoCAD SHX Text

DESCRIPTION

AutoCAD SHX Text

PROJECT

AutoCAD SHX Text

ISSUED FOR SHPO

AutoCAD SHX Text 12/18/2019

Sheets and Views