About this file

This document contains a floor plan for a proposed Fisher House and related federal contract opportunity for design/build construction services for site utilities.

The floor plan depicts the layout of a proposed Fisher House to be built at the Veterans Affairs Medical Center in Columbia, South Carolina. It shows the arrangement and dimensions of rooms, common areas, doors, windows and other building elements. The related federal contract opportunity is solicited by the Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 7. It seeks design/build construction services for site utilities to support the proposed Fisher House depicted in the floor plan. The solicitation number is 36C24720R0050 and responses are due by the date specified in the opportunity description. The awarded contractor will be responsible for providing design and construction of site utilities for the Fisher House project.

View the file

Other files

File Type Posted
SC20200028 01-03-2020.docx DOCX document
PAST PERFORMANCE QUESTIONNAIRE.rtf RTF text file
4A2Floorplan.pdf PDF
Siteplan.pdf PDF
A3 elevation.pdf PDF
FH-COLUMBIA-SCRENDERING.jpg JPG image
36C24720R0050_1.docx DOCX document
6elevation.pdf PDF
FH Qualifaction SIte Plan.docx DOCX document

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

REF

REF

REF

REF

PANTRY

STACKABLE

WASHER

+ DRYERS

D/W

D/W

HALL

LIVING ROOMDINING ROOM FOYER

KITCHEN

LAUNDRY

OFFICE

FAMILY ROOM

CLOSET

TOILET

GUEST

CLO.

CLO.

CLO.

CLO.

A1 # 1 # 1

C

# 3 # 24

C

# 3 # 15

D

# 5 # 16

D

# 5 # 23

C

# 3 # 19

C

# 3 # 20

C # 7

C

# 3 # 29

C

# 3 # 38C

# 3 # 34

C

# 3 # 33

# 5

# 4

# 3a # 3

# 3a # 2

# 7

F # 18

# 7

F # 21

# 7

F # 25

# 7

F # 14

# 7

F # 32

# 7

F # 35

# 7

F # 28

# 7

F # 39

B1 # 9 # 8

E # 10

A # 11 # 2

# 12 A

# 2

# 26 A

# 2

# 13 A

# 2

D

# 5 # 17

D

# 5 # 22

# 27 A

# 2

D

# 5 # 30

D

# 5 # 31

D

# 5 # 37

D

# 5 # 36

# 4 #40 C3

# 4 # 41

UP

UP

#4a

CONC. PAVING

4" THICK W/ WWM TYPICAL

CONC. PAVING

4" THICK W/ WWM TYPICAL

CONC. PAVING

4" THICK W/ WWM TYPICAL

CONC. PAVING

4" THICK W/ WWM TYPICAL

ELEVATOR

EQUIP. ROOM

2 3

13 14

# 6 # 5

D #3a # 8

F.E.

SCULPTURE

PEDESTAL

CLO.

CLO.

CLO.

CLO.

DD

D

B

E E

FF

FF

E

E

F F

FF

# 71

# 73

# 74

# 76

E

E

E

E

E

E

FD

C

C

C

C

B B

B

B

B

B A-5

B A-5

BATH

# 75 # 72

S F

DH

HS

S

DH

S F

HS

S

S

S F

HS

HS

HS

HSF

DH

S

HS

DH

S F

FD

S

S

F.E.C

F.E.C

DH

F.E.C

HS

G A-11

A A-5A-5

A

A-11.1

TE

LE

PH

O

N E

EQ

U

IP

M

EN

T

S H

ELV

IN

G

SHELVING

SHELVING

SHELVING

S H

EL

V

IN

GS

H

EL

V

IN

G

B # 48

# 4 # 41a# 4

# 40a

B

B

B

MECHANICAL

FD

HS

WH

WH

BOILER

ELECTRICAL

PANEL

CLEARANCE

FIRE SPRINKLER

FS

FS

D

DD

F.E.C

B

B

B

B

B B B

A

A

A

A

A

A

A

A

BE

C3

C4 C4

C5

C5

C5

B2

B2

B2

B2

B2

B2

# 77 A

# 2

FIRE

STAIR

"B"

FIRE

STAIR

"A"

HALL

HALL

BEDROOM BEDROOM

BEDROOMBEDROOM

BEDROOM

BEDROOM

BEDROOM

BEDROOM

HALL

HALL

BATH

BATH

BATH

BATH

BATH

BATH

BATH

BATH

# 3

#4a

#4a

# 3a

# 8

# 8

# 8 # 8

# 8

# 8

A N N

F

FACP

HS

C2

C2

REF

100 101102

112a

116 113

121a

117 120

FIRE

STAIR

"B"

FD

FD

FD

FD

FD

FD

FD

FD

101102

103 106105104

108 107

GUEST

CLOSET

OFFICE

BOOK SHELVES

HS HS

FC

F.E.

F.E.

A A-5

A-5 B

C A-6

A A-5

B A-5

C A-6

A

A

B

B

B

B

B

B

E E

E

E

E

E

E

E

E

E

E

E EE

E

E

E

E

E

E

E

E

E

E

E

E 5

'-0

6'-4" 12'-9 1/8" 12'-1 1/2" 11'-2 1/2" 6'-4"

6'-8 3/4" 23'-4"

7'-0" 23'-0 3/4"

'-1

/2

'-6

'-0

'-9

7'-0"23'-0 3/4"

7'-2"

'-0

"EQ EQ EQ 1'-0"

'-5

/8

'-5

/8

EQEQEQ

'-1

/2

'-1

/2

'-1

/2

'-1

/2

'-1

/2

'-1

/2

'-1

/2

'-6

3'-3"12'-0 13/16"

70'-0"

'-0

4" Ø STEEL PIPE

COLUMN

4" Ø STEEL PIPE

COLUMN

4" Ø STEEL PIPE

COLUMN

4" Ø STEEL

PIPE

STUCCO

WALL WARP CONC.

PAVING TO

DOOR

SADDLE

4" THICK CONC.

APRON TYP.

SEE DWG # A-5

FOR DETAIL

7'-2" 7'-2"

52'-0"

'-0

5'-0"

6 3/4"

1'-0"

'-0

12'-0 13/16"

'-3

'-5

/8

'-0

'-0

'-5

/8

'-0

'-3

'-9

'-0

42'-1 9/16" 42'-1 9/16"

4'-2" 4'-2"

136'-3 1/8"

7'-6 3/4"21'-6"

7'-2"7'-2"7'-2"4'-11 3/16"8'-1 9/16" 5'-1 3/16" 7'-11 9/16"

'-9

/8

'-9

/8

6'-4" 4'-8" 11'-10" 6'-4" 11'-10" 4'-8" 6'-4"

2'-10" 10'-10 1/4" 2'-10"

'-1

/8

1'-4 5/8" 1'-4 5/8"

52'-0"

19'-3 1/2"

42'-1 9/16"42'-1 9/16"

BEARING WALLS AND PARTITIONS

SEE PLANS AND SECTIONS

DOOR DETAILS

Door types # Door # Hardware set #

CMU WALL 8" THICK/ 2HR FIRE RATED

SECTION

Section. # Sheet #

ELEVATION

Elev. # Sheet #

# 4

C # 4

A-# F

F A-#

LEGEND

WINDOW #22

F

S

HS

F.E.

F.A SPEAKER/ STROBE

(WALL MTD. 80"AFF)

F.A MANUAL PULL STATION

F.A VISUAL STROBE DEVICE

(WALL MTD. 80" AFF)

WALL HUNG

FIRE EXTINGUISHER

RECESSED

FIRE EXTINGUISHER + CAB

DOOR HOLD OPEN DEVICE

REQUIRES POWER FEED

AND INTERCONNECT TO

FIRE ALARM SYSTEM

DH

FLOOR DRAINFD

2HR FIRE RATED PARTITIONS

XXXX PLAQUE

MOUNTING 64"AFF

B PARTITION TYPE

SEE DWG A-6

FIRE CURTAIN

SEE DWG A-10.1FOR DETAILS

NOTE : GC TO COORDINATE - ELECTRICAL

CONTRACTOR TO PROVIDE REQUIRED

CONNECTION TO FIRE ALARM SYSTEM

FACP SEMI-RECESSED

FIRE ALARM CONTROL PANEL

RECESSED

REMOTE ANNUNCIATORANN

F.E.C

FIRST FLOOR PLAN

A - 1

A R

C H

IT

E

C T

S

D E

S

IG

N E

R S

D E

S

IG

N T

E C

H A

S S

O C

IA

T

E S

B R

O A

D W

A Y

, N E

W Y

O R

K , N

Y

Foundation, Inc.

Fisher House

Draper Aden Associates Engineering Surveying Environmental Services phone 804.264.2228 / fax 804.264.8773 / mobile 804.937.6717 www.daa.com

A R C H I T E C T S + D E S I G N E R S

D E S I G N T E C H A S S O C I A T E S

PROPOSED FISHER HOUSE

VAMC COLUMBIA-SC

7 7 N o r t h C e n t r e A v e n u e S u i t e 3 1 5

R o c k v i l l e C e n t r e , N e w Y o r k 1 1 5 7 0

2 1 2 - 9 4 4 - 7 7 7 0 F a x 2 1 2 - 9 4 4 - 7 8 0 3

AutoCAD SHX Text O

AutoCAD SHX Text O

AutoCAD SHX Text 1/4"=1'-0"

AutoCAD SHX Text

REVISION

AutoCAD SHX Text

DRAWING

AutoCAD SHX Text

DATE

AutoCAD SHX Text

SCALE

AutoCAD SHX Text

DATE

AutoCAD SHX Text DRAWING No.

AutoCAD SHX Text

DESCRIPTION

AutoCAD SHX Text

(858) 679-8989 Fax (858) 679-8959

AutoCAD SHX Text Poway, CA 92064-8819

AutoCAD SHX Text 14288 Danielson Street

AutoCAD SHX Text S T R U C T U R A L E N G I N E E R S

AutoCAD SHX Text

KUSHKAKI

AutoCAD SHX Text

TAYLOR

AutoCAD SHX Text

HOROWITZ

AutoCAD SHX Text Suite #200

AutoCAD SHX Text A

AutoCAD SHX Text One Liberty Plaza 165 Broadway, 22nd Floor New York, NY 10006 T: 212.354.5656 F: 212.354.5668

AutoCAD SHX Text K

AutoCAD SHX Text F

AutoCAD SHX Text ARLINGTON / BOSTON / MEXICO CITY / MINNEAPOLIS / NEW YORK / BOSTON / MEXICO CITY / MINNEAPOLIS / NEW YORK BOSTON / MEXICO CITY / MINNEAPOLIS / NEW YORK / MEXICO CITY / MINNEAPOLIS / NEW YORK MEXICO CITY / MINNEAPOLIS / NEW YORK / MINNEAPOLIS / NEW YORK MINNEAPOLIS / NEW YORK / NEW YORK NEW YORK PHILADELPHIA / PRINCETON / PUEBLA / ROCHESTER / STAMFORD/ PRINCETON / PUEBLA / ROCHESTER / STAMFORD PRINCETON / PUEBLA / ROCHESTER / STAMFORD/ PUEBLA / ROCHESTER / STAMFORD PUEBLA / ROCHESTER / STAMFORD/ ROCHESTER / STAMFORD ROCHESTER / STAMFORD/ STAMFORD STAMFORD

AutoCAD SHX Text ENGINEERING / ANALYSIS & TESTING / BUILDING MANAGEMENT SYSTEMS / CENTRAL UTILITIES / ANALYSIS & TESTING / BUILDING MANAGEMENT SYSTEMS / CENTRAL UTILITIES / ANALYSIS & TESTING / BUILDING MANAGEMENT SYSTEMS / CENTRAL UTILITIES ANALYSIS & TESTING / BUILDING MANAGEMENT SYSTEMS / CENTRAL UTILITIES ANALYSIS & TESTING / BUILDING MANAGEMENT SYSTEMS / CENTRAL UTILITIES / BUILDING MANAGEMENT SYSTEMS / CENTRAL UTILITIES / BUILDING MANAGEMENT SYSTEMS / CENTRAL UTILITIES BUILDING MANAGEMENT SYSTEMS / CENTRAL UTILITIES BUILDING MANAGEMENT SYSTEMS / CENTRAL UTILITIES / CENTRAL UTILITIES / CENTRAL UTILITIES CENTRAL UTILITIES CENTRAL UTILITIES CODE CONSULTING / COMMISSIONING / CRITICAL SYSTEMS / ENERGY & SUSTAINABILITY / COMMISSIONING / CRITICAL SYSTEMS / ENERGY & SUSTAINABILITY / COMMISSIONING / CRITICAL SYSTEMS / ENERGY & SUSTAINABILITY COMMISSIONING / CRITICAL SYSTEMS / ENERGY & SUSTAINABILITY COMMISSIONING / CRITICAL SYSTEMS / ENERGY & SUSTAINABILITY / CRITICAL SYSTEMS / ENERGY & SUSTAINABILITY / CRITICAL SYSTEMS / ENERGY & SUSTAINABILITY CRITICAL SYSTEMS / ENERGY & SUSTAINABILITY CRITICAL SYSTEMS / ENERGY & SUSTAINABILITY / ENERGY & SUSTAINABILITY / ENERGY & SUSTAINABILITY ENERGY & SUSTAINABILITY ENERGY & SUSTAINABILITY FIRE PROTECTION / IT/AV/SECURITY / LIGHTING DESIGN / SPECIAL INSPECTIONS / IT/AV/SECURITY / LIGHTING DESIGN / SPECIAL INSPECTIONS / IT/AV/SECURITY / LIGHTING DESIGN / SPECIAL INSPECTIONS IT/AV/SECURITY / LIGHTING DESIGN / SPECIAL INSPECTIONS IT/AV/SECURITY / LIGHTING DESIGN / SPECIAL INSPECTIONS / LIGHTING DESIGN / SPECIAL INSPECTIONS / LIGHTING DESIGN / SPECIAL INSPECTIONS LIGHTING DESIGN / SPECIAL INSPECTIONS LIGHTING DESIGN / SPECIAL INSPECTIONS / SPECIAL INSPECTIONS / SPECIAL INSPECTIONS SPECIAL INSPECTIONS SPECIAL INSPECTIONS www.AKFGroup.com

AutoCAD SHX Text

PROJECT

AutoCAD SHX Text

ISSUED FOR SHPO

AutoCAD SHX Text 12/18/2019

Sheets and Views
A-1