4a-Runway -100% Drawings_Part 16.pdf
PDF 12 MB Posted
- Solicitation number
- RFP 171 260000002245 2
- Issued by
- Macomb County, Michigan
About this file
This is a comprehensive 100% final submittal drawing package prepared by Mead & Hunt, Inc. for the State of Michigan Department of Technology, State Facilities Administration, Design and Construction Division, related to airfield improvements at Selfridge Air National Guard Base in Lansing, Michigan. The project addresses Runway Encroachment Solution – Project #2, specifically Task 1 – MCC Mitigate Runway Encroachment, and constitutes part of a larger runway construction and electrical infrastructure modernization initiative issued on June 5, 2026.
The drawing package spans 467 sheets and details comprehensive airfield electrical infrastructure including in-pavement lighting systems, runway edge and threshold lighting configurations, approach lighting systems (ALSF-1), sequenced flasher installations, isolation transformer platforms, high-intensity approach light bars, PAPI (Precision Approach Path Indicator) systems, runway guidance signs, arresting gear markers, runway distance markers, Instrument Landing System (ILS) components including glide slope and localizer antenna installations with 50-foot antenna towers, and associated electrical conduit systems, grounding details, cable raceways, and foundation specifications. The design encompasses extensive specifications for concrete foundations, reinforcement patterns, drainage systems, lightning protection systems, obstruction lighting, and interconnected electrical control systems with detailed requirements for contractor installation methodology, tolerances, material specifications, and quality assurance protocols. The project requires substantial coordination with FAA personnel for final equipment calibration and flight checks, with contractor notification requirements of six months and three months prior to ILS-related work to schedule required government involvement in equipment disconnection, reconnection, and recalibration.
View the file
Other files
Show all 19
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
A
B
C
D
E
F
G
H
J
K
L
M
N
P
SU
BM
IT
TE
D B
Y:
C H
EC
KE
D B
Y:
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
IS
SU
E D
AT
E:
SI
ZE
M
AR
K
D
ES
C R
IP
TI
O N
D
AT
E
SHEET ID
SHEET OF 467
MI ANGB
ST
AT
E O
F M
IC
H
IG
AN
D
EP
AR
TM
EN
T
O F
TE
C
H N
O
LO
G Y, ST
AT
E
FA
C
IL
IT
IE
S
AD
M
IN
IS
TR
AT
IO
N D
ES
IG
N A
N D
C O
N
ST
R U
C
TI
O N
D
IV
IS
IO
N
LA
N C
IN
G
, M
IC
H
IG
AN
M
AN
AG
EM
EN
T, A N
D B
U D
G
ET
JU
N E
5, AN
SI
D
M
EA
D
H U
N T, IN
C
D
EM
IN
G W
AY
M
ID
D
LE
TO
N , W
I
SE
LF
R
ID
G E
AI
R
N
AT
IO
N
AL
G
U
AR
D B
AS
E, M
IC
H
IG
AN
R
U N
W
AY
E N
C R
O
AC
H M
EN
T
SO
LU
TI
O
N
PR
O
JE
C
T #2
AI
R
FI
EL
D
IM
PR
O
VE
M
EN
TS
TA
SK
M C
C A
M
IT
IG
AT
E R
U N
W
AY
E N
C R
O
AC
H M
EN
T
Y
TY
PE
B -3
0% F
IN
AL
S U
BM
IT
TA
L
M
JR
D
LU
PA
B
D R
P
AI
R
FI
EL
D
E
LE
C
TR
IC
AL
D
ET
AI
LS
EA504
9/16"
FIGURE: 17A
EDGE OF FULL STRENGTH
PAVEMENT
#6 SOLID BARE COPPER
COUNTERPOISE
2" SCH 40 PVC
REINFORCEMENT CAGE
(FIGURE 12)
2" THREADED WEEP HOLE FOR
DRAINAGE (ALL CANS) (OPTIONAL)
ASPHALT
SHOULDER
FULL STRENGTH
PAVEMENT
CONCRETE
ENCASEMENT
INSTALL COUNTERPOISE AT HALF
DISTANCE FROM EDGE OF
PAVEMENT TO LIGHT FIXTURE
AND MINIMUM 8" DEEP
3/4" X 10'-0" CU GROUND ROD WITH
EXOTHERMIC CONNECTION, SEE PLANS
FOR LOCATION
3"
7' -6
2' -0
(M
IN
)3"
FIGURE: 17C
9/16" 2 1/2"
1/ 4"
7 1/2" Ø
1/
2"
FIGURE: 18A
L-830 ISOLATION
TRANSFORMER
4 ANTI-ROTATION FINS
3/16" X 3/4" X 3"
3'-0" CABLE SLACK ON
EACH SIDE
#8 AWG L-824, 5KV, CABLE
(AS INDICATED IN LAYOUT PLANS)
TRANSFORMER STAND
LOAD RING
BRAIDED COPPER GROUND STRAP
2" DRAIN
2" SCH 40 PVC CONDUIT
THREADED COUPLING
OR GROMMET
INTERNAL GROUND LUG
L-823 PRIMARY CONNECTOR
GROUND CABLE
(FIGURE 3A AND 3B)
STAINLESS STEEL CABLE TAG
L-868B 1'-0" Ø (2'-1" OR 2'-6" DEEP)
CLASS 1, # OF HUBS AS SHOWN ON
PLANS (NOTE 12)
SPACER RINGS
(NOTE 4 )
SNOW PLOW RING WITH O-RING
(STYLE 3)
L-823 SECONDARY CONNECTOR
IN-PAVEMENT LIGHT FIXTURE,
STYLE 3 (NOTE 7)
2 PIECE LOCK WASHER
EXTERNAL GROUND LUG1. INSTALL CORNER EDGE OF SNOW PLOW RING FLUSH WITH PAVEMENT SURFACE WITH A TOLERANCE OF +0", -1/16" .
2. SUBMIT ALL BASE CAN INSTALLATION TECHNIQUES, METHODS, MATERIALS, ETC., TO THE GOVERNMENT FOR REVIEW AND APPROVAL PRIOR TO THE START OF
WORK.
3. BEFORE PAVING MAY PROCEED, THE CONTRACTOR MUST DEMONSTRATE TO THE GOVERNMENT THAT THE BASE CANS ARE AT THE CORRECT LOCATION, ELEVATION, AZIMUTH AND ROTATION AND THAT THE PROPER CLEARANCE EXISTS BETWEEN THE BASE CAN AND THE PAVER.
4. THE SPACER RING IS DESIGNED AS A NOMINAL 3/4" THICKNESS. THE SPACER RING MAY BE REQUIRED TO BE THINNER OR THICKER DEPENDING ON BASE CAN INSTALLATION AND PAVING TECHNIQUES / TOLERANCES. THIS CONTRACTOR MUST MEASURE AND DETERMINE THE REQUIRED THICKNESS OF EACH INDIVIDUAL SPACER RING REQUIRED TO PUT THE AIRFIELD LIGHTING FIXTURE AT THE CORRECT ELEVATION, AZIMUTH AND ROTATION. THE CONTRACTOR MAY USE MULTIPLE SPACER RINGS OF VARYING HEIGHTS. NO MORE THAN 3 SPACER RINGS MAY BE USED ON ANY ONE LIGHT INSTALLATION THE MAXIMUM HEIGHT
DISPLACEMENT FOR ONE OR MORE SPACER RINGS WILL BE 2" OR LESS.
5. THE FINISHED PAVEMENT SURFACE MUST BE PROTECTED FROM FOREIGN SUBSTANCES WHICH COULD CAUSE STAINING, I.E. CONCRETE, OIL, ETC. THE CONTRACTOR MUST IMMEDIATELY CLEAN ALL SPILLS AND CORRECT/CLEAN ANY STAINED SURFACES AT THE CONTRACTOR'S EXPENSE.
6. THE BASE CAN COVER MOUNTING BOLTS MUST EXTEND THRU THE BASE CAN MOUNTING FLANGE INTO THE BASE CAN A MINIMUM OF ½". THE BOLTS MUST BE
THREADED THE FULL LENGTH OF THE BOLT.
7. FOR BLANK BASE CANS, DELETE LIGHT FIXTURE AND INSTALL ¾" STEEL BLANK COVER.
8. CONNECT TO GROUND ROD.
9. INSTALL TOP OF EDGE OF SNOW PLOW RING FLUSH WITH PAVEMENT SURFACE WITH A TOLERANCE OF +0", -1/16".
10. IF THE DISTANCE BETWEEN THE EDGE OF THE SNOW RING AND CONCRETE IS 1/8" (3mm) OR LESS, SEAL TOP OF OPENING WITH P-605 SILICONE SEALANT AND
DELETE THE P-606 COMPOUND.
11. THE TOP OF FIXTURE MUST NOT EXCEED THE TOP OF THE SNOW PLOW RING (+0", -1/8").
12. THE CONTRACTOR MUST PRE-ASSEMBLE IN-PAVEMENT LIGHT FIXTURE WITH SNOW PLOW RINGS TO ASSURE EACH INDIVIDUAL UNIT ASSEMBLY IS WITHIN TOLERANCE. USE A STRAIGHT EDGE TO VERIFY THE FIXTURE IS LEVEL (TO 1/8"). ANY UNITS NOT WITHIN THIS TOLERANCE WILL BE REJECTED. ASSURE SNOW
PLOW RINGS ARE CONFIGURED WITH CORRECT NUMBER AND WIDTH OF OPENINGS.
13. THE CONTRACTOR MUST INSTALL A 25" DEEP BASE CAN WHERE THE PCC PAVEMENT THICKNESS IS 15" AND MUST INSTALL A 30" DEEP BASE CAN WHERE THE
PAVEMENT THICKNESS IS 20".
14. CONTRACTOR MUST ENSURE SEALANT INSTALLATION IS IN ACCORDANCE WITH ELEVATION TOLERANCES OF LIGHT FIXTURE INSTALLATION.
15. CONTRACTOR MUST ENSURE SNOW PLOW RINGS ARE COMPATIBLE AND APPROPRIATE FOR USE WITH BASE CANS AND FIXTURES.
16. USE DRAINAGE LAYER AND CONCRETE.
#3/8-16 HEX HEAD CERAMIC-METALLIC FLUOROPOLYMER COATED,
GRADE 2 BOLT, LENGTH IS DETERMINED BY THICKNESS OF FLANGE
AND/OR SPACER RINGS 6 PLACES (NOTE 4)
DRAWING NOTES - FIGURES 18A AND 18B
4" DRAINAGE LAYER (NOTE
16)
CONCRETE (NOTE 16)
ATTACH CABLE TO GROUND ROD
AND REINFORCEMENT CAGE
(FIGURES 3A AND 3B)
REINFORCEMENT CAGE
SEE FIGURE 12
1'-3" OR 1'-8" PCC ± PAVING
TOLERANCES
FINISHED PAVEMENT SURFACE
SLOPE PER CIVIL PLANS
#6 SOLID BARE COPPER
COUNTERPOISE
APPLY CONCRETE BOND
BREAKER OVER TRENCH
COMPACTED BASE COARSE
4" DRAINAGE LAYER, (NOTE 16)
CONCRETE, (NOTE 16)
1'-3" OR 1'-8" PCC
± PAVING TOLERANCES
FINISHED PAVEMENT SURFACE
SLOPE PER CIVIL PLANS
1'-1"
3" M
IN
3" M
IN
2" SCH 40 PVC CONDUIT
CONDUIT IS ROTATED 90°
AROUND BASE CAN TO SHOW
CONDUIT CONNECTION TO BASE
CAN, SEE SECTION FOR
CONDUIT INSTALLATION
DOWN SLOPE SIDE OF
BASE CAN/LIGHT/SNOW
RING INSTALLATION,
(FIGURE 11B)
INSTALL BASE
CAN/FIXTURE LEVEL
PAVEMENT SLOPE
CONCRETE
ENCASEMENT
2" SCH 40
PVC ELBOW
3'-0"
CORE
8" (2 m m
12" PORTLAND CEMENT-STABILIZED
BASE COURSE
LIME OR CEMENT TREATED
SUBGRADE
TO UNDERDRAIN
DRAIN
PAVEMENT CROSS SLOPE STRAIGHTEDGE
PAVEMENT
PAVEMENT
LIGHT BASE
TRAFFIC DIRECTION
C R
O
SS
S
LO
PE
FIXTURE
STRAIGHTEDGE
CHECK AT
FIXTURE EDGE
DRAWING NOTES
1. STRAIGHTEDGE SHOULD BE 10'-0" LONG. NOTCH APPROXIMATELY 1" HIGH, AND ABOUT 1"-2" LONGER THAN
FIXTURE DIAMETER.
2. A 1/16" ALLEN WRENCH IS A GOOD TOOL TO USE TO DETERMINE HEIGHT TOLERANCE OF FIXTURE (OR SNOW PLOW RING) RELATIVE TO LOW SIDE OF PAVEMENT. SLIDE STRAIGHTEDGE ON TO FIXTURE OR SNOW PLOW RING EDGE TO MEASURE. IF STRAIGHTEDGE RIDES UP ON THE EDGE, FIXTURE IS TOO HIGH. IF EDGE IS MORE
THAN 1/16 INCH BELOW STRAIGHTEDGE, THE FIXTURE IS TOO LOW.
3. CHECK STRAIGHTEDGE IN BOTH DIRECTIONS TO VERIFY THERE IS NO UNUSUAL PAVEMENT BUILD-UP IN THE
PROXIMITY OF THE LIGHT THAT MIGHT BLOCK PART OF THE LIGHT BEAM.
4. A LEVEL ON TOP OF THE STRAIGHTEDGE CAN VERIFY COMPLIANCE WITH LEVEL TOLERANCE.
FIGURE: 19B
12" PORTLAND
CEMENT-TREATED
SUBGRADE
LIME OR CEMENT
TREATED SUBGRADE
LIGHT BASE MOUNTING IN SHOULDER PAVEMENT PLANK13 SCALE: NTS
AIRFIELD ISOLATION TRANSFORMER PLATFORMK8 SCALE: NTS
STRAIGHTEDGE CHECK DETAILH2 SCALE: NTS
IN-PAVEMENT LIGHT MATERIALSC15 SCALE: NTS
FIGURE: 18BB9 SCALE: NTS
IN-PAVEMENT LIGHT IN FULL STRENGTH PCCF9 SCALE: NTS
B
C
D
E
F
G
H
J
K
L
M
N
P
SU
BM
IT
TE
D B
Y:
C H
EC
KE
D B
Y:
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
IS
SU
E D
AT
E:
SI
ZE
M
AR
K
D
ES
C R
IP
TI
O N
D
AT
E
SHEET ID
SHEET OF 467
MI ANGB
ST
AT
E O
F M
IC
H
IG
AN
D
EP
AR
TM
EN
T
O F
TE
C
H N
O
LO
G Y, ST
AT
E
FA
C
IL
IT
IE
S
AD
M
IN
IS
TR
AT
IO
N D
ES
IG
N A
N D
C O
N
ST
R U
C
TI
O N
D
IV
IS
IO
N
LA
N C
IN
G
, M
IC
H
IG
AN
M
AN
AG
EM
EN
T, A N
D B
U D
E
5, AN
SI
D
M
EA
D
H U
N T, IN
C
D
EM
IN
G W
AY
M
ID
D
LE
TO
N , W
I
SE
LF
R
ID
G E
AI
R
N
AT
IO
N
AL
G
U
AR
D B
AS
E, M
IC
H
IG
AN
R
U N
W
AY
E N
C R
O
AC
H M
EN
T
SO
LU
TI
O
N
PR
O
JE
C
T #2
AI
R
FI
EL
D
IM
PR
O
VE
M
EN
TS
TA
SK
M C
C A
M
IT
IG
AT
E R
U N
W
AY
E N
C R
O
AC
H M
EN
T
Y
TY
PE
B -3
0% F
IN
AL
S U
BM
IT
TA
L
M
JR
D
LU
PA
B
D R
P
SE
Q U
EN
C
E
FL
AS
H
ER
S
FO
U
N D
AT
IO
N D
ET
AI
LS
EA505
225A, 240/120 V
PANELBOARD
25 KVA, 2400V
240/120V XFMR
TVSS
6"x6"X24" NEMA 3R
SQUARE DUCT
SFL MASTER CONTROL
CABINET
SFL POWER AND CONTROL RACK INSTALLATION DETAILF6 SCALE: NTS
GFCI
W/ WP
BOX
COMMUNICATION
ENCLOSURE,
24"X20"X8"
NEMA 4,
HOFFMAN
A24H2010SSLP3PT
WITH:
F/O PATCH
PANEL AND I/O
EXTENDER
1-4" SCH. 40 PVC WITH:
NCOMING 2400V FROM 50
kVA TSFL TRANSFORMER IN
AIRFIELD LIGHTING (AFL)
VAULT
2" GRSC SUPPORT
POST (TYP.)
1-5/8" GALVANIZED
UNITSTRUT CHANNEL
(TYP.)
ELEVATION
PLAN VIEW
2" GRSC
ABOVE
GROUND
2" SCH. 40 PVC WITH:
12-STRAND, SINGLE MODE
FIBER FROM AFL VAULT
2" SCH. 40 PVC
POWER AND
CONTROL TO ICC
CABINETS
4" GRSC ABOVE GROUND WITH:
2-1/C #2 5 kV, 133% EPR
INSULATION
1-#2, 600V, GROUND
4/0 GROUND
LOOP
#2#4
THOMPSON #28R
DOWN CONDUCTOR
(TYP.)
5/8" X 12" COPPER AIR
TERMINAL, BLUNT TIP,
THOMPSON 665BT
(TYP.)
BONDING CLAMP,
THOMPSON 240X (TYP.)
AIR TERMINAL PIPE
CLAMP THOMPSON
240XP-5 AND 27A
ADAPTER (TYP.)
#6 REBAR
#4 TIES
L-810
OBSTRUCTION
LIGHT
PHOTOCELL WITH
TWIST-LOCK BASE
RAIN CAP (TYP.)
12"
5' -0
EX. GRADE EX. GRADE
10'-0"
12"12"
3' -0
#6 REBAR
#4 TIES @
12" O. C.
3/4" X 10' COPPER CLAD
GROUND ROD (TYP.)
4/0 GROUND LOOP
EXOTHERMIC WELD
EXOTHERMIC WELD
NOTE: BOND ALL METAL SURFACES USING
A #6 GREEN INSULATED WIRE
8"8"
2-2" SCH. 40 PVC TO MASTER
CONTROL PANEL WITH:
3-#8, THWN
1-#8, 600V GND
1-MANHATTAN M8628101O
CABLE. SEE EA520 FOR
CONNECTION DIAGRAM
2-2" PVC TO
NEXT FLASHER
STATION WITH
POWER AND
CONTROL
CABLES
2" GRSC ABOVE
GROUND (TYP.)
2" FRANGIBLE
COUPLING (TYP.)
JUNCTION BOX
INDIVIDUAL
CONTROL
CABINET
2" PVC TO
FLASHER
WITH:
MANUFACTURER
SUPPLIED
CABLE
ICC CABINET INSTALLATION DETAILF17 SCALE: NTS
#6
GRND
3/4" X 10' COPPER CLAD
GROUND ROD (TYP.)
3' -6
1" PVC
SFL PANEL SCHEDULEN15 SCALE: NTS
#6 REBAR
#4 TIES
PLAN VIEW
ELEVATION
4.00'
3.
8"
3/4" X 10' COPPER CLAD
GROUND ROD (TYP.)
4/0 GROUND LOOP
#4 BONDING WIRE
B
C
D
E
F
G
H
J
K
L
M
N
P
SU
BM
IT
TE
D B
Y:
C H
EC
KE
D B
Y:
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
IS
SU
E D
AT
E:
SI
ZE
M
AR
K
D
ES
C R
IP
TI
O N
D
AT
E
SHEET ID
SHEET OF 467
MI ANGB
ST
AT
E O
F M
IC
H
IG
AN
D
EP
AR
TM
EN
T
O F
TE
C
H N
O
LO
G Y, ST
AT
E
FA
C
IL
IT
IE
S
AD
M
IN
IS
TR
AT
IO
N D
ES
IG
N A
N D
C O
N
ST
R U
C
TI
O N
D
IV
IS
IO
N
LA
N C
IN
G
, M
IC
H
IG
AN
M
AN
AG
EM
EN
T, A N
D B
U D
E
5, AN
SI
D
M
EA
D
H U
N T, IN
C
D
EM
IN
G W
AY
M
ID
D
LE
TO
N , W
I
SE
LF
R
ID
G E
AI
R
N
AT
IO
N
AL
G
U
AR
D B
AS
E, M
IC
H
IG
AN
R
U N
W
AY
E N
C R
O
AC
H M
EN
T
SO
LU
TI
O
N
PR
O
JE
C
T #2
AI
R
FI
EL
D
IM
PR
O
VE
M
EN
TS
TA
SK
M C
C A
M
IT
IG
AT
E R
U N
W
AY
E N
C R
O
AC
H M
EN
T
Y
TY
PE
B -3
0% F
IN
AL
S U
BM
IT
TA
L
M
JR
D
LU
PA
B
D R
P
AI
R
FI
EL
D
E
LE
C
TR
IC
AL
D
ET
AI
LS
EA506
2" FEMALE ADAPTER
COUPLING
2" FEMALE ADAPTER
COUPLING
ANCHOR PLATE
TO RUNWAY END
3500 PSI
CONCRETE
6- 5/
8" ±1
/1 6"
6- 5/
8" ±1
/1 6"
4- 1/
2"
2'-0"±1/16"1'-3 1/2"±1/16"
7-3/4"±1/16" 7-3/4"±1/16"
4- 1/
2"
1- 1/
8" ±1
/1 6"
1' -6
3' -0
DRAWING NOTES - FIGURE 34:
1. REFER TO FIGURE 35, SECTION A.
2. ACTUAL DIMENSIONS MAY VARY. COORDINATE WITH MANUFACTURER PRIOR TO CONSTRUCTION AND
CONSTRUCT PER MANUFACTURER'S REQUIREMENTS.
TO RUNWAY END
TO RUNWAY END
#4 TIES 12"
O.C.
TIES
2" RIGID
GALVANIZED
STEEL ELBOW
3" CLEAR COVER
ALL AROUND
6' -0
" M
IN
D
EP
TH
3'-0"
AUGER HOLE AND
CAST AGAINST SOIL
CONCRETE
1" X 1" CHAMFER (TYP)
J-SHAPE 3 4" ANCHOR BOLT
PER MANUFACTURER (2 EA)
(MAT'L ASTM-F-1554)
1' -6
" M
IN
3'-0"
ANCHOR PLATE PER
MANUFACTURER (1 EACH)
J-SHAPE 3 4"ANCHOR
BOLT (TYP.)
NOTE:
DEPTH LENGTH SHALL
BE FIELD VERIFIED AND
BASED ON SOIL
CONDITIONS.
3' -0
" M
IN
CONSTRUCTION JOINT
SECTION
SCALE: NTS
A
SECTION
SCALE: NTS
B
CONCRETE 2" RIGID
GALVANIZED
STEEL ELBOW
6-#5 BARS EQUALLY
SPACED
PLAN
L-830 ISOLATION
TRANSFORMERS
(NUMBER AS
REQUIRED)
L-867 SIZE D HANDHOLE
(FIGURE 31)
TO FLASHER POWER SUPPLY
WHERE INSTALLED (FIGURE 32)
MAST
3/4" FLEXIBLE CONDUIT
2" LB CONDULET
(FIGURE 37, CONDULET DETAIL)
EDGE OF CONCRETE
PAD FOR FLASHER
POWER SUPPLY AND
JUNCTION BOX
WHERE INSTALLED
(FIGURE 32)
3/4" FLEXIBLE CONDUIT.
ROUTE TOWARDS
DIRECTION OF TILT.
PROVIDE ENOUGH SLACK
SO CONDUIT IS NOT
STRAINED
2" PVC CONDUIT
L-867 SIZE D HANDHOLE
(FIGURE 31)
2" PVC
CONDUIT
CONCRETE
FOUNDATION
D
IS
TA
N
C E
VA
R
IE
S
M
AX
IM
U
M
0' -0
M
AI
N
TA
IN
S
TR
AI
G
H T
LI
N
E
BE
TW
EE
N S
TA
TI
O N
S
TO RUNWAY END
3' -0
DIRECTION
OF TILT
TILT
AXIS
SECTION
SCALE: NTS
C
SECONDARY PLUG AND
RECEPTACLE ON END OF CABLE
(NUMBER PER MANUFACTURER)
FRANGIBLE COUPLING
2" RGS ELBOW
2" PIPE COUPLING
CABLES AND CABLE CLAMP
TO STEADY BURN LIGHTS OR
FLASHER AS REQUIRED
2" LB CONDULET WITH CAST
METAL COVER AND GASKET
2" STEEL COMPRESSION TYPE
CONNECTOR
2" EMT NIPPLE
TOP OF TOWER FOUNDATION
TO RUNWAY END
2" TO 3/4" REDUCING
BUSHING
3/4" LIQUID TIGHT
FLEXIBLE CONDUIT
FEMALE CONNECTOR
3/4" LIQUID TIGHT
FLEXIBLE CONNECTOR,
MALE
DRAWING NOTES - FIGURE 37:
1. PROVIDE NUMBER OF CABLES AS REQUIRED. REFER TO SYSTEM WIRING DIAGRAMS.
2. FACE CONDULET AWAY FROM RUNWAY END AND TOWARD APPROACH.
BOND TUBE TO
STAND PLATE
TILTING AND LOWER DEVICE
PER MANUFACTURER
FIGURE 35, FOUNDATION DETAIL
AND FIGURE 36, WIRING DETAIL
FINISHED GRADE
T-BAR ASSEMBLY
CENTERLINE
OF LIGHTS
FLASHER (WHERE REQUIRED)
(FIGURE 43, FAA-E-2628)
STEADY BURNING APPROACH
LIGHT (FIGURE 42, FAA-E-982)
2" M
AX
C U
T
TU
BE
T
O L
EN
G
TH
(L
(N
O
TE
TOP OF TUBE
BOTTOM
OF TUBE
H
H
EI
G H
T
6' -1
" T O
1'
-1
(S
EE
A
PP
R O
AC
H
L
IG
H
TI
N G
PR
O
FI
LE
P
LA
N
3- 3/
4"
3" ±1
(7
5m m
±2 5m m
DRAWING NOTES - FIGURE 33:
1. DETERMINE EXACT LENGTH OF TUBE IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS.
FOUNDATION FOR LIR STRUCTURE MG-20 PLAN VIEWK14 SCALE: NTS
TYPICAL MG-20 LIR STRUCTURE TOWER WIRING DETAILG8 SCALE: NTS
2" LB CONDUIT DETAILA8 SCALE: NTS
FOUNDATION FOR LIR STRUCTURE MG-20 SECTIONS A AND BB15 SCALE: NTS
TYPICAL MG-20 LIR STRUCTUREJ2 SCALE: NTS
#4 TIES 12" O.C.
BREAKAWAY ANCHOR BOLT. INSTALL
WHERE NEEDED TO MEET
FRANGEABILITY REQUIREMENTS
POLE BASE PLATE
B
C
D
E
F
G
H
J
K
L
M
N
P
SU
BM
IT
TE
D B
Y:
C H
EC
KE
D B
Y:
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
IS
SU
E D
AT
E:
SI
ZE
M
AR
K
D
ES
C R
IP
TI
O N
D
AT
E
SHEET ID
SHEET OF 467
MI ANGB
ST
AT
E O
F M
IC
H
IG
AN
D
EP
AR
TM
EN
T
O F
TE
C
H N
O
LO
G Y, ST
AT
E
FA
C
IL
IT
IE
S
AD
M
IN
IS
TR
AT
IO
N D
ES
IG
N A
N D
C O
N
ST
R U
C
TI
O N
D
IV
IS
IO
N
LA
N C
IN
G
, M
IC
H
IG
AN
M
AN
AG
EM
EN
T, A N
D B
U D
E
5, AN
SI
D
M
EA
D
H U
N T, IN
C
D
EM
IN
G W
AY
M
ID
D
LE
TO
N , W
I
SE
LF
R
ID
G E
AI
R
N
AT
IO
N
AL
G
U
AR
D B
AS
E, M
IC
H
IG
AN
R
U N
W
AY
E N
C R
O
AC
H M
EN
T
SO
LU
TI
O
N
PR
O
JE
C
T #2
AI
R
FI
EL
D
IM
PR
O
VE
M
EN
TS
TA
SK
M C
C A
M
IT
IG
AT
E R
U N
W
AY
E N
C R
O
AC
H M
EN
T
Y
TY
PE
B -3
0% F
IN
AL
S U
BM
IT
TA
L
M
JR
D
LU
PA
B
D R
P
AI
R
FI
EL
D
E
LE
C
TR
IC
AL
D
ET
AI
LS
EA507
2" FEMALE ADAPTER1" X 1" CHAMFER
(TYP)
PLAN
CONCRETE
#4-TIES @ 1'-0" OC
6' -0
3'-0"
5'-0"±1/16"
3"
1'-2"
ANCHOR ROD PER MANUFACTURER
(2 EA PER PIER) (MATERIAL
ASTM-F1554) GALVANIZED
2" RGS CONDUIT ELBOW
GALVANIZED ANCHOR PER
MANUFACTURER (1 EACH)
CLPIER
CLPIER
3" CLEAR
COVER ALL AROUND
CLPIER
5'-3"±1/16"
3'-0" Ø REINFORCED
CONCRETE PIER PER
MANUFACTURER (TYP)
3"
3"
3"
1'-3 1/2"±1/16"
3' -5
3'
-5 "4 1/
2"
1/ 2"1
1/ 8"
±1 /1
6"
SECTION
SCALE: NTS
A
6-#5 BARS EQUALLY SPACED
ELEVATION
PLAN
CONCRETE FOUNDATIONS
AND REINF (FIGURE 40)
3/4" LIQUID-TIGHT FLEX CONDUIT
WITH CABLES TO STEADY BURN
LIGHT
3/4" LIQUID-TIGHT FLEX
CONDUIT WITH CABLES TO
FLASHER
CONCRETE
FOUNDATION
2" PVC CONDUIT
STAND PLATE PER MANUFACTURERMAST PER MANUFACTURER
GRADE
2" LB CONDULET
ANCHOR BOLTS
MOUNTING FRAME ASSEMBLY
2" PVC CONDUIT
L-867 HANDHOLE SIZE D
2" PVC CONDUIT
MOUNTING FRAME ASSEMBLY
2" RGS
CONDUIT
2" FLEXIBLE PVC
CONDUIT
2" LB CONDULET
L-867 HANDHOLE SIZE D
2" PVC CONDUIT
FLASHER POWER SUPPLY
FLASHER JUNCTION BOX
3'-0"
DISTANCE VARIES DISTANCE VARIES
DISTANCE VARIES
3/4" FLEXIBLE CONDUIT
TILT AXIS
2" FLEXIBLE PVC
CONDUIT
TOWARDS RUNWAY THRESHOLD
FAA-E-982 STEADY
BURNING APPROACH LIGHT LAMP POWER CABLES #10
TERMINAL BLOCK ASSEMBLY
(AND SHORTING DEVICE WHERE USED)
TOP OF 6" ID FIBERGLASS
TUBE
CENTERLINE OF LIGHT
#12 GND THWN-2
#18 SCREW, STAR WASHER,
LOCK WASHER, AND NUT
(NOTE 2)
TEE BAR ASSEMBLY PER
MANUFACTURER
TUBE CAP ASSEMBLY
PER MANUFACTURER
TUBE CAP CLAMP
6" ID FIBERGLASS TUBE
LE
N
G
TH
P
ER
M
AN
U
FA
C
TU
R
ER
DRAWING NOTES - FIGURE 42:
1. MEASURE DISTANCE BETWEEN CENTER OF LIGHT AND TOP OF TUBE USING ACTUAL EQUIPMENT INSTALLED.
2. ATTACH #12 GROUND TO FIXTURE HOUSING BY INSTALLING A #8 SCREW THROUGH HOLE PROVIDED IN BOTTOM OF HOUSING.
SAND AWAY PAINT AND ANODIZING AROUND HOLE ON INSIDE OF HOUSING TO BARE METAL. PUSH SCREW UP THROUGH HOLE AND INSTALL STAR WASHER OVER SCREW ON INTERIOR OF HOUSING. CRIMP AN INSULATED RING TERMINAL ON THE END OF THE GROUND WIRE AND INSTALL ON SCREW. PLACE LOCK WASHER AND NUT ON SCREW AND TIGHTEN. VERIFY WITH MANUFACTURER LENGTH AND SIZE OF SCREW, STAR WASHER, LOCK WASHER, AND NUT TO BE UTILIZED TO MAINTAIN
CLEARANCE FROM TERMINAL BLOCK ASSEMBLY.
TUBE CAP
TUBE CAP CLAMP
FIBERGLASS
MAST PER
MANUFACTURER
BRACKET CLAMP
TEE BAR ASSEMBLY
1/2" LIQUID-TIGHT FLEXIBLE
CONDUIT WITH FLASHER CABLES
1/2" 90° ELBOW
CONNECTOR
FAA-E-2628
SEQUENCED
FLASHER
TOWARDS RUNWAY THRESHOLD
STEADY BURN APPROACH LIGHT
(FIGURE 42)
1/2" 90° ELBOW CONNECTOR
#12
GND THWN-2
JUNCTION BOX
FLASHER
BRACKET
INSTALL
GROUND
LUG
(NOTE 2)
DRAWING NOTES - FIGURE 43:
1. FLASHER JUNCTION BOX / BRACKET AND BRACKET CLAMP FURNISHED AS AN ASSEMBLY. INSTALL ON MAST
PER MANUFACTURER'S REQUIREMENTS.
2. INSTALL GROUND LUG ON ONE OF THE 2 ALUMINUM ANGLES INSIDE THE JUNCTION BOX AND ROUTE A #12
THWN-2 FROM FLASHER AND FIBERGLASS MAST TO LUG. TERMINATE GROUND WIRE ON LUG.
TYPICAL MG-20 LIR STRUCTURE TOWER WIRING DETAILJ13 SCALE: NTS
FOUNDATIONS FOR MG-20 LIR STRUCTURESA14 SCALE: NTS
TOWER MOUNTED STEADY BURNING APPROACH LIGHT DETAILJ3 SCALE: NTS
TOWER MOUNTED SFL AND APPROACH LIGHT DETAILA3 SCALE: NTS 3'-0"
B
C
D
E
F
G
H
J
K
L
M
N
P
SU
BM
IT
TE
D B
Y:
C H
EC
KE
D B
Y:
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
IS
SU
E D
AT
E:
SI
ZE
M
AR
K
D
ES
C R
IP
TI
O N
D
AT
E
SHEET ID
SHEET OF 467
MI ANGB
ST
AT
E O
F M
IC
H
IG
AN
D
EP
AR
TM
EN
T
O F
TE
C
H N
O
LO
G Y, ST
AT
E
FA
C
IL
IT
IE
S
AD
M
IN
IS
TR
AT
IO
N D
ES
IG
N A
N D
C O
N
ST
R U
C
TI
O N
D
IV
IS
IO
N
LA
N C
IN
G
, M
IC
H
IG
AN
M
AN
AG
EM
EN
T, A N
D B
U D
E
5, AN
SI
D
M
EA
D
H U
N T, IN
C
D
EM
IN
G W
AY
M
ID
D
LE
TO
N , W
I
SE
LF
R
ID
G E
AI
R
N
AT
IO
N
AL
G
U
AR
D B
AS
E, M
IC
H
IG
AN
R
U N
W
AY
E N
C R
O
AC
H M
EN
T
SO
LU
TI
O
N
PR
O
JE
C
T #2
AI
R
FI
EL
D
IM
PR
O
VE
M
EN
TS
TA
SK
M C
C A
M
IT
IG
AT
E R
U N
W
AY
E N
C R
O
AC
H M
EN
T
Y
TY
PE
B -3
0% F
IN
AL
S U
BM
IT
TA
L
M
JR
D
LU
PA
B
D R
P
AI
R
FI
EL
D
E
LE
C
TR
IC
AL
D
ET
AI
LS
EA508
LAMP TRIGGER
#16 (WHITE)
REMOTE FLASHER HEAD
SIDE VIEW ELEVATION
2" RGS CONDUIT
ELBOW ASSEMBLY
2"PIPE
COUPLING
L-823 MALE
CONNECTOR
(NOTE 3)
L-823 FEMALE
CONNECTOR
(NOTE 3)
2 #16
INTERLOCK
WIRES
CONNECTOR,
FEMALE
3 REQUIRED
(SIZE FOR WIRE)
FRANGIBLE
COUPLING
CONNECTOR,
MALE
3 REQUIRED
(SIZE FOR WIRE)
CABLE CLAMP
LAMP RETURN
(BLACK)
CAUTION
LAMP POWER
#16 2KV (WHITE)
STROBE
LIGHT HEAD
FRANGIBLE
COUPLING
2" RGS CONDUIT
ELBOW
ASSEMBLY
FROM FLASHER
POWER SUPPLY
(NOTES 5 & 7)CONCRETE
PEDESTAL 8"
ROUND OR
SQUARE
SEE DETAIL A
2" EMT
FINISHED
GRADE
DIRECTION OF
APPROACH
2' -6
M
IN
IM
U M
D
EP
TH
O
R
BE
LO
W
F R
O
ST
D
EP
TH
N O
TE
DRAWING NOTES - FIGURE 45:
1. MAXIMUM MOUNTING HEIGHT OF CONFIGURATION INDICATED IS 5'-11" FOR MOUNTING INSTALLATION OF MORE
THAN 6'-0" SEE TOWER INSTALLATION DETAILS.
2. TERMINATE ALL CONDUITS WITH A STANDARD GROUNDING BUSHING.
3. CONNECTION MUST BE CLEAN AND DRY WITH A LIGHT COATING OF SILICONE GREASE ONLY.
4. CONTINUITY OF POWER CABLES MUST BE MAINTAINED BETWEEN FLASHER STATIONS. WHERE SPLICES ARE REQUIRED, THEY MUST BE EPOXY RESIN TYPE WITH PLASTIC SHELL. EQUIP CONDUCTORS WITH MECHANICAL
WIRE CLAMPS.
5. GROUND CLEARANCE OF ELECTRICAL BOXES MUST BE DETERMINED IN FIELD, AND MUST BE 8" MINIMUM.
6. FLASHER POWER SUPPLY / JUNCTION BOX UNIT MUST BE LOCATED 35' FROM EXTENDED CENTERLINE OF
RUNWAY.
7. INSERT LAMP RETURN WIRE INTO CABLE CLAMP PRIOR TO FINAL ASSEMBLY/TIGHTENING.
3/8" - 16 CERAMIC
FLUOROPOLYMER COATED
STEEL BOLT (TYP FOR 6)
2 PIECE LOCK WASHER
3/8" - 16 CERAMIC FLUOROPOLYMER
COATED BOLT (TYP FOR 6)
2 PIECE LOCK WASHER
BRAIDED COPPER GROUND STRAP
LOAD RING
3'-0" CABLE SLACK ON
EACH SIDE
L-868C, 1'-3" Ø, 2'-0"
DEEP GALVANIZED STEEL
L-830 ISOLATION
TRANSFORMER
4 ANTI-ROATION FINS
3/16" X 3/4" X 3"
TRANSFORMER STAND (OPTIONAL)
L-824, 5KV, CABLE
L-823 SECONDARY CONNECTOR
SNOW PLOW RING WITH O-RING
IN-PAVEMENT LIGHT FIXTURE
(STYLE 2) OR 3/4" STEEL
BLANK COVER
STAINLESS STEEL CABLE TAG
L-823 PRIMARY CONNECTOR
2" SCH 40 PVC CONDUIT
THREADED COUPLING
OR GROMMET
INTERNAL GROUND LUG
GROUND CABLE
(FIGURES 3A AND 3B)
CONDUIT TO
HANDHOLE
ASPHALT
OVERRUN
REINFORCING
BARS, (FIGURES
48D AND 48E)
TO HANDHOLE
TO UNDER DRAIN
RUNWAY CENTERLINE
EXTENDED AND JOINT
D
IR
EC
TI
O N
O F
LI
G
H T
3'-6" - 5'-0"
3' -0
2'-0" 3'-6" - 5'-0" 3'-6" - 5'-0" 3'-6" - 5'-0" 2'-0"
NOTE: LIGHT SPACING AND NUMBER OF LIGHTS VARY
REFER TO SYSTEM LAYOUT PLANS FOR DIMENSIONS
2' -0
M
IN
#6 GROUND WIRE
3/4" Ø X 10'-0"
GROUND ROD
#6 COUNTERPOISE
D
IR
EC
TI
O N
O F
LI
G
H T
HORIZONTAL REINFORCING
2'-0"
2" SCH 40 PVC
CONCRETE
FOUNDATION 3" MIN
COVER ALL BARS
2" SCH 40 PVC
TO HANDHOLE
(FIGURE 31)
INTERNAL
GROUND
LUG (TYP)
#6 GROUND WIRE
RUNWAY CENTERLINE
EXTENDED
2" SCH 40 PVC TO
HANDHOLE (FIGURE 31)
SCALE: NTS
SAND BACKFILL
ASPHALT
VARIABLE DEPTH COMPACTED
BASE COURSE
EXISTING 10" - 1'-0" COMPACTED
BASE COURSE
#4 COUNTERPOISE
3" (7
5m m
3" (75mm)
3" (75mm)
NOTE:
TRANSVERSE SECTION VIEW SIMILAR TO LONGITUDINAL SECTION VIEW.
ASPHALT
VARIABLE DEPTH
COMPACTED BASE
COURSE
# 4 HORIZONTAL BARS
(SEE TIE BAR CAGE ON EA503
EVENLY SAW CUT (TYP)
2' -6
" M
IN
IM
U
M
6" 2'
-0
#5 VERTICAL BARS
EACH FACE
FIGURE 48F, DETAIL 5
1/
2"
CL
3"
OPTIONAL CONSTRUCTION
JOINT
BRAIDED GROUND STRAP
SECTION
SCALE: NTS
A 46B
DRAWING NOTES - FIGURE 46E:
1. DETAILS FOR HIGH INTENSITY APPROACH IN-PAVEMENT LIGHT FIXTURE/BASE CAN ONLY. INSTALLATION
METHODOLOGY INDICATED FOR CONTRACTOR INFORMATION ONLY. THE METHODOLOGY INDICATED ON THIS SHEET IS GENERAL IN NATURE. FINAL INSTALLATION METHODOLOGY MUST BE DETERMINED BY THE
CONTRACTOR.
2. SEE CIVIL PLANS FOR TYPICAL PAVEMENT SECTION.
CL
FLEXIBLE PAVEMENT
COMPACTED BASE
COARSE
SUBGRADE
EXISTING SUBBASE
SUBGRADE
EXISTING
SUBBASE
CL
2' -6
M
IN
IM
U M
3'-0"
SAW CUT FINISHED
ASPHALT AND EXCAVATE
CL
8" (2 m m
3'-0" (0.9M)
MAKE ALL
NECESSARY CONDUIT/
COUNTERPOISE
CONNECTIONS
SAND BAG (TYP)
SUPPORT BRACE
FACTORY ATTACHED PLYWOOD
COVER TO MIMIC PHYSICAL DIAMETER
AND THICKNESS OF SNOW PLOW
RING. (COORDINATE WITH BASE
CAN/LIGHT FIXTURE MANUFACTURER)
COMPLETELY WRAP PLYWOOD
COVER IN ROOFING PAPER COMPACTED BASE
COARSE
FLEXIBLE PAVEMENT
DRAWING NOTES - FIGURE 46F:
1. DETAILS FOR HIGH INTENSITY APPROACH IN-PAVEMENT LIGHT FIXTURE/BASE
CAN ONLY. INSTALLATION METHODOLOGY INDICATED FOR CONTRACTOR
INFORMATION ONLY. THE METHODOLOGY INDICATED ON THIS SHEET IS GENERAL
IN NATURE. FINAL INSTALLATION METHODOLOGY MUST BE DETERMINED BY THE
CONTRACTOR.
2. SEE CIVIL PLANS FOR TYPICAL PAVEMENT SECTION.
REMOTE FLASHER INSTALLATION 6'-0" MAX.J14 SCALE: NTS
IN-PAVEMENT HIGH INTENSITY APPROACHB15 SCALE: NTS
GROUNDING CONNECTIONS (AIR FORCE PROJECTS)L7 SCALE: NTS
TYPICAL HIGH INTENSITY APPROACH LIGHT BARG7 SCALE: NTS (AIR FORCE/ ARMY)
EXISTING CONDITIONS BEFORE TRENCHINGB6 SCALE: NTS
SET L-868 CAN AND FRAMEWORKC1 SCALE: NTS
SAWCUT ASPHALT AND TRENCHC11 SCALE: NTS
IN-PAVEMENT HIGH INTENSITY APPROACH LIGHT BARL1 SCALE: NTS
CONDUIT INSTALLATIONF1 SCALE: NTS
B
C
D
E
F
G
H
J
K
L
M
N
P
SU
BM
IT
TE
D B
Y:
C H
EC
KE
D B
Y:
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
IS
SU
E D
AT
E:
SI
ZE
M
AR
K
D
ES
C R
IP
TI
O N
D
AT
E
SHEET ID
SHEET OF 467
MI ANGB
ST
AT
E O
F M
IC
H
IG
AN
D
EP
AR
TM
EN
T
O F
TE
C
H N
O
LO
G Y, ST
AT
E
FA
C
IL
IT
IE
S
AD
M
IN
IS
TR
AT
IO
N D
ES
IG
N A
N D
C O
N
ST
R U
C
TI
O N
D
IV
IS
IO
N
LA
N C
IN
G
, M
IC
H
IG
AN
M
AN
AG
EM
EN
T, A N
D B
U D
E
5, AN
SI
D
M
EA
D
H U
N T, IN
C
D
EM
IN
G W
AY
M
ID
D
LE
TO
N , W
I
SE
LF
R
ID
G E
AI
R
N
AT
IO
N
AL
G
U
AR
D B
AS
E, M
IC
H
IG
AN
R
U N
W
AY
E N
C R
O
AC
H M
EN
T
SO
LU
TI
O
N
PR
O
JE
C
T #2
AI
R
FI
EL
D
IM
PR
O
VE
M
EN
TS
TA
SK
M C
C A
M
IT
IG
AT
E R
U N
W
AY
E N
C R
O
AC
H M
EN
T
Y
TY
PE
B -3
0% F
IN
AL
S U
BM
IT
TA
L
M
JR
D
LU
PA
B
D R
P
AI
R
FI
EL
D
E
LE
C
TR
IC
AL
D
ET
AI
LS
EA509
CL
FLEXIBLE PAVEMENT
COMPACTED BASE COARSE
SUBGRADE
EXISTING SUBBASE
REBAR NOT SHOWN
FOR CLARITY
PLACE CONCRETE,
TROWEL CONCRETE
FLUSH TO SURFACE
OF FINISHED ASPHALT
AND TO EDGE OF
PLYWOOD COVERS
CL
CL
REMOVE FRAMEWORK, PLYWOOD
COVER, AND SANDBAGS
INSTALL SNOW PLOW RING AND FILL
SPACE WITH P-606 SEALING COMPOUND
SUBGRADE
EXISTING
SUBBASE
REBAR NOT SHOWN
FOR CLARITY
SUBGRADE
EXISTING SUBBASE
REBAR NOT SHOWN
FOR CLARITY
INSTALL THRESHOLD APPROACH LIGHTING
FIXTURE AND COMPLETE WIRING
FLEXIBLE PAVEMENT
COMPACTED BASE COARSE
FLEXIBLE PAVEMENT
COMPACTED BASE COARSE
DRAWING NOTES - FIGURE 46G:
1. DETAILS FOR HIGH INTENSITY APPROACH IN-PAVEMENT LIGHT FIXTURE/BASE CAN ONLY.
INSTALLATION METHODOLOGY SHOWN FOR INSTALLER INFORMATION ONLY. THE METHODOLOGY
SHOWN ON THIS SHEET IS GENERAL IN NATURE. FINAL INSTALLATION METHODOLOGY MUST BE
DETERMINED BY THE INSTALLER.
2. SEE CIVIL PLANS FOR TYPICAL PAVEMENT SECTION.
1'-0" Ø L-867 BASE,
NON-LOAD BEARING FOR
STEADY BURNING
APPROACH LIGHT2" FLEXIBLE PVC
CONDUIT 1'-0" LONG (TYP)
2" PVC CONDUIT
TO NEXT LIGHT
STATION, SEE
SYSTEM LAYOUT
PLAN
2" PVC
CONDUIT
STEADY BURNING
APPROACH LIGHT
VA
R
IE
S
BY
S
TA
TI
O N
SE
E
AP
PR
O
AC
H
LI
G H
T
PR
O
FI
LE
P
LA
N
REFER TO SYSTEM LAYOUT PLAN FOR LIGHT SPACING
COVER PLATE
BONDING JUMPER.
BRAIDED COPPER
GROUND STRAP
GROUND LUG (TYP)
#6 THWN
EQUIP GND
(NOTE 8)
ELEVATION
COVER PLATE AND
GASKET (TYP)
1" CHAMFER
(TYP)
FRANGIBLE
COUPLING
(TYP)
FINISHED
GRADE
3/4" Ø X 10'-0" LONG
GROUND ROD
LIGHT
6" M
IN
2'-0"
MIN
BARE COPPER
COUNTERPOISE
TO NEXT LIGHT BAR
CL
TO HANDHOLE TO HANDHOLE
DRAWING NOTES - FIGURE 47:
1. PLACE ALL ELEVATED LIGHT FIXTURES ON 12" L-867, NON-LOAD BEARING BASES.
2. MAXIMUM MOUNTING HEIGHT OF CONFIGURATION INDICATED IS 6'-0". FOR MOUNTING INSTALLATION OF
MORE THAN 6'-0", SEE TOWER INSTALLATION DETAILS.
SYMBOL LEGEND:
EXPANSION JOINT
2" SCH 40 PVC OR
HDPE CONDUIT
2" EXPANSION
COUPLING
RUNWAY OVERRUN
PAVEMENT
TURF
FIGURE 48B, C, D, AND F FOR
TYPICAL LIGHT INSTALLATION
TO HANDHOLE, SEE
LAYOUT PLANS
8"
6"
CONCRETE
4'-0" MOW PAD
CIRCUIT R1 CONDUIT
R1 THRESH
2" SCH 40 PVC OR
HDPE CONDUIT
R1 THRESH R1 THRESH R1 THRESH R1 THRESH R1
CIRCUIT R2 CONDUIT
ASPHALT
BLAST PAD
EXPANSION JOINT, SEE
DETAIL THIS SHEET
DIRECTION OF GREEN LENS
25'-0" SHOULDER PAVEMENT
OUTLINE OF BASE CAN
DIRECTION OF
OBSCURED LENS
3' -0
INSTALL EXPANSION JOINT
BETWEEN FULL STRENGTH
RUNWAY PAVEMENT AND
CONCRETE FOUNDATION
FOR THRESHOLD LIGHTS
FULL STRENGTH PCC TO UNDERDRAIN
UNDERDRAIN SHOWN FOR LOCATION OF
UNDERDRAIN PURPOSES ONLY
BIDIRECTIONAL FIXTURE GREEN/OBSCURED
UNIDIRECTIONAL FIXTURE GREEN
SYMBOL LEGEND:
R1 - EDGE CIRCUIT #1
R19 - EDGE CIRCUIT #2
THRESH - THRESHOLD CIRCUIT
SOLID LINE IS OUTLINE OF
BASE CAN
THRESHOLD CIRCUIT
CONDUIT
BURLAP COVERING,
SEE DETAIL THIS
SHEET
EXPANSION JOINT
SCH 40 PVC
FLEXIBLE PVC
CONDUIT
WRAP WITH LAYERS OF BURLAP,
TOTAL 1" TO ALLOW FOR
EXPANSIONNYLON OR WIRE
TIES (TYP)
FIXTURE CIRCUIT
(TYP)
DRAWING NOTES - FIGURE 48A:
1. NOT ALL FIXTURES IN THRESHOLD BAR ARE INDICATED FOR CLARITY. THRESHOLD BAR CONTINUES
ACROSS RUNWAY AND IS SYMMETRICAL ABOUT RUNWAY CENTERLINE.
2. INTERWEAVE CONDUITS AS INDICATED.
3. REFER TO FIGURE 56 FOR TYPICAL WIRING DIAGRAM.
4. NO MORE THAN FIVE LIGHTS SHOULD BE IN BAR BEFORE AN EXPANSION JOINT IS INSTALLED.
5. AT EACH EXPANSION JOINT, CUT BACK THE TEN #6 REBAR 2-1/2 INCHES CLEAR ON EACH SIDE OF THE EXPANSION JOINT LOCATIONS. PLACE A MINIMUM OF FOUR 1-1/4 INCH DOWELS AT 20 INCHES LONG CONFORMING TO SECTION 32 13 14.13 CENTERED ON THE JOINT AND PARALLEL WITH THE PROPOSED SURFACE. ALIGN DOWELS PER TOLERANCES SPECIFIED WITHIN 32 13 14.13. DOWELS TO BE PLACED 7.5-INCHES CLEAR FROM EACH FACE OF THE GRADE BEAM AND 9-INCHES CLEAR FROM THE TOP AND BOTTOM OF THE GRADE BEAM. PLACE EXPANSION CAPS ON ONE END OF EACH DOWEL AND GREASE DOWEL PRIOR TO CONCRETE PLACEMENT. PLACE CONCRETE IN A MANNER NOT TO DISPLACE OR MOVE
THE DOWEL DURING THE CONCRETE PLACEMENT.
R1 THRESH R1 THRESH R1 THRESH R1 THRESH R1 THRESH R1
UNDERDRAIN
2-2" SCH 40 PVC
OR HDPE
CONDUITS
3' -0
FIXTURE CIRCUIT (TYP)
SEE FIGURE 48C
EXPANSION JOINT (TYP)
FLEXIBLE PVC CONDUIT
ACROSS JOINT (TYP)
5'-0"
(TYP)
CONTINUOUS REINFORCING
AS DETAILED
6" COMPACTED
BASE COURSE
CONDUIT
(TYP)
3" C
O
VE
R (T
YP
SEE FIGURE 48C, D,
AND F FOR TYPICAL
LIGHT INSTALLATION
CONCRETE
SUBGRADE
FLUSH MOUNTED THRESHOLD
LIGHT (T) (TYP)
T/E T T/E T T T T T T T T
THRESHOLD/ END
LIGHT (T/E) (TYP)
DRAWING NOTES - FIGURE 48B:
1. NOT ALL FIXTURES IN THRESHOLD BAR ARE INDICATED FOR CLARITY. THRESHOLD BAR CONTINUES
ACROSS RUNWAY AND IS SYMMETRICAL ABOUT RUNWAY CENTERLINE.
2. INTERWEAVE CONDUITS AS INDICATED.
3. REFER TO FIGURE 56 FOR TYPICAL WIRING DIAGRAM.
FINISHED PAVEMENT
SURFACE, SLOPE PER
CIVIL PLANS
CONCRETE
FIGURE 48F, DETAIL 6
REINFORCING
COMPACTED BASE COURSE
10'-0" OR 5'-0"
TO NEXT LIGHT
AS INDICATED
GROUND CABLE
10'-0" OR 5'-0"
TO NEXT LIGHT
AS INDICATED
FINISHED PAVEMENT
SURFACE, SLOPE PER
CIVIL PLANS
CONCRETE
OVERRUN PAVEMENTFULL STRENGTH PAVEMENT
1'-6" PCC PAVEMENT
#4 COUNTERPOISE
(NOTE 8)
4" DRAINAGE LAYER (AIR
FORCE/ ARMY)
COMPACTED BASE
COURSE
INTERLEAVE CONDUITS IF
REQUIRED (FIGURE 48A)
PCC REFER TO
PAVING PLANS
CONCRETE BEAM
FIGURE 48D (NOTE 12)
RUNWAY THRESHOLD
3'-0"
8" M
IN
PLACE CONCRETE AND LEVEL FLUSH TO FINISHED ASPHALTN16 SCALE: NTS
REMOVE BRACE/PLYWOOD COVER AND INSTALL SNOW PLOW RINGK16 SCALE: NTS
BASE CAN IN PLACEF16 SCALE: NTS
TYPICAL ELEVATED HIGH INTENSITY APPROACH LIGHT BAR 0' TO 6'-0" MAX.A13 SCALE: NTS
RUNWAY THRESHOLD WING BAR LIGHT FOUNDATION - ELEVATION VIEWA4 SCALE: NTS (AIR FORCE)
RUNWAY THRESHOLD WING BAR LIGHT FOUNDATION - PLAN VIEWK6 SCALE: NTS
BURLAP COVERING DETAILH11 SCALE: NTS EXPANSION JOINT DETAILH7 SCALE: NTS
SECTIONF1 SCALE: NTS
THRESHOLD LIGHT IN CONCRETE BEAML1 SCALE: NTS
1-1/4" DOWEL
BAR (TYP.)
SEE FIG. 48A
NOTE 5
1-1/4" DOWEL
BAR (TYP.)
SEE FIG. 48A
NOTE 5
B
C
D
E
F
G
H
J
K
L
M
N
P
SU
BM
IT
TE
D B
Y:
C H
EC
KE
D B
Y:
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
IS
SU
E D
AT
E:
SI
ZE
M
AR
K
D
ES
C R
IP
TI
O N
D
AT
E
SHEET ID
SHEET OF 467
MI ANGB
ST
AT
E O
F M
IC
H
IG
AN
D
EP
AR
TM
EN
T
O F
TE
C
H N
O
LO
G Y, ST
AT
E
FA
C
IL
IT
IE
S
AD
M
IN
IS
TR
AT
IO
N D
ES
IG
N A
N D
C O
N
ST
R U
C
TI
O N
D
IV
IS
IO
N
LA
N C
IN
G
, M
IC
H
IG
AN
M
AN
AG
EM
EN
T, A N
D B
U D
E
5, AN
SI
D
M
EA
D
H U
N T, IN
C
D
EM
IN
G W
AY
M
ID
D
LE
TO
N , W
I
SE
LF
R
ID
G E
AI
R
N
AT
IO
N
AL
G
U
AR
D B
AS
E, M
IC
H
IG
AN
R
U N
W
AY
E N
C R
O
AC
H M
EN
T
SO
LU
TI
O
N
PR
O
JE
C
T #2
AI
R
FI
EL
D
IM
PR
O
VE
M
EN
TS
TA
SK
M C
C A
M
IT
IG
AT
E R
U N
W
AY
E N
C R
O
AC
H M
EN
T
Y
TY
PE
B -3
0% F
IN
AL
S U
BM
IT
TA
L
M
JR
D
LU
PA
B
D R
P
AI
R
FI
EL
D
E
LE
C
TR
IC
AL
D
ET
AI
LS
EA510
FURNISH AND INSTALL 1'-5 1/4" Ø SNOW
PLOW RING MOUNTED ON L-868C 1'-3" Ø
BASE CAN
BOLT HOLE FOR SNOW PLOW RING
BOLT HOLE FOR LIGHT FIXTURE
DIRECTION OF LIGHT
3/8" -16 CERAMIC FLUOROPOLYMER COATED STEEL
BOLT AND 2 PIECE LOCKWASHER (TYP)
P-606 RIGID SEALANT
(NOTE 10)
L-868C BASE CAN
SNOW PLOW RING
(NOTE 1)
PAVEMENT SURFACE,
SLOPE PER CIVIL PLANSO-RING
IN GROOVE
TOP EDGE OF IN-PAVEMENT
LIGHT FIXTURE (NOTE 11)
SEALANT FAA P-605
(NOTE 10)
FACTORY ATTACHED
FIXTURE GROUND LUG
(BY LIGHT FIXTURE
MANUFACTURER)
BRAIDED COPPER
GROUND STRAP
NOTE 1
NOTE 11
INSIDE AND OUTSIDE OF BASE CAN
SNOW RING
SEE INSTALLATION
METHODOLOGY BELOW
1/4"
MAX
1'-3 1/2" Ø
TOP OF BASE CAN
10"
11 1/4"
1'-2 1/4"
1'-5 1/4"
1/ 2" 1/ 2"
DRAWING NOTES - FIGURE 48E:
1. INSTALL CORNER EDGE OF SNOW PLOW RING FLUSH WITH
PAVEMENT SURFACE WITH A TOLERANCE OF +0", -1/16".
CHECK TOLERANCE WITH STRAIGHT EDGE. SEE FIGURE 19B.
2. SUBMIT ALL BASE CAN INSTALLATION TECHNIQUES,
METHODS, MATERIALS, ETC., TO THE GOVERNMENT FOR
REVIEW AND APPROVAL PRIOR TO THE START OF WORK.
3. BEFORE BACKFILLING AROUND THE BASE CANS, THE
CONTRACTOR MUST DEMONSTRATE TO THE GOVERNMENT
THAT THE BASE CANS ARE AT THE CORRECT LOCATION,
ELEVATION, AZIMUTH, AND ROTATION.
4. PROTECT THE FINISHED PAVEMENT SURFACE FROM
FOREIGN SUBSTANCES WHICH COULD CAUSE STAINING, I.E.,
CONCRETE, OIL, ETC.. THE CONTRACTOR MUST
IMMEDIATELY CLEAN ALL SPILLS AND CORRECT/CLEAN ANY
STAINED SURFACES AT NO ADDITIONAL COST TO THE
GOVERNMENT.
5. THE BASE CAN COVER MOUNTING BOLTS MUST EXTEND
THRU THE BASE CAN MOUNTING FLANGE INTO THE BASE
CAN A MINIMUM OF 0.5". THE BOLTS MUST BE THREADED
THE FULL LENGTH OF THE BOLT.
6. CONCRETE AROUND BASE CANS AND DUCT/CONDUIT MUST
BE COMPLETELY CONSOLIDATED BY MECHANICAL MEANS
AND FREE OF ANY VOIDS.
7. FOR BLANK BASE CANS, DELETE LIGHT FIXTURE AND
INSTALL 3/4" STEEL BLANK COVER.
8. AIR FORCE / ARMY AIRFIELDS: CONNECT LOCAL GROUND
ROD TO BASE CANS. ROUTE COUNTERPOISE AROUND BASE
CANS. NAVY AIRFIELDS: CONNECT COUNTERPOISE TO BASE
CANS.
9. INSTALL TOP OF EDGE OF SNOW PLOW RING FLUSH WITH
PAVEMENT SURFACE WITH A TOLERANCE OF +0", -1/16"
(1.6mm).
10. IF THE DISTANCE BETWEEN THE EDGE OF THE SNOW RING
AND CONCRETE IS 1/8" OR LESS, SEAL TOP OF OPENING
WITH P-605 SEALANT AND DELETE THE P-606 COMPOUND.
11. THE TOP OF FIXTURE MUST NOT EXCEED THE TOP OF THE
SNOW PLOW RING (+0, -1/8").
12. INSTALL FINISHED SURFACE OF CONCRETE BEAM FLUSH
WITH ADJACENT PAVEMENT (+0, -1/16").
FAA-E-982 PAR 56 LAMP
HOLDER ASSEMBLY
2" ELECTRICAL METALLIC
TUBING (EMT) LENGTH AS
REQUIRED
APPLY SMALL AMOUNT OF
GREASE/ANTI-SEIZE COMPOUND
BEFORE INSERTION INTO
COMPRESSION RING
COMPRESSION RING W/ NUT
FURNISHED W/ FRANGIBLE
COUPLING, TIGHTEN
SUFFICIENTLY TO HOLD
EMT RIGID
COVER PLATE AND GASKET
RED OR GREEN COLOR
FILTER WHERE REQUIRED
FINISHED
GRADE
FRANGIBLE
COUPLING
FIELD ATTACHED CONNECTOR
L-823 PLUG AND RECEPTACLE
1'-0" Ø, L-867 BASE
NON-LOAD BEARING
6' -0
M
AX
IM
U M
M O
U N
TI
N
G H
EI
G
H T
6"
MINIMMUM CONCRETE ENCASEMENT
DRAWING NOTES - FIGURE 49:
1. GREEN COLOR FILTER FOR THRESHOLD BAR.
2. RED COLOR FILTER FOR BARRETTES PRE-THRESHOLD AND
TERMINATING BARS (ALSF-1).
3. NO COLOR FILTER FOR CENTERLINE BARS; 1000' BAR (ALSF-1).
REINFORCEMENT
PER FIGURE 12
LEGENDRUNWAY
RUNWAY THRESHOLD
RUNWAY EDGE LIGHTS
STA 15+00
STA 30+00
STA 5+00
STA 3+00
NOTE 2
STA 10+00
THRESHOLD BAR
5'-0" SPACING (AIR
FORCE)
PRE-THRESHOLD BAR
INBOARD LIGHT IN LINE
WITH RUNWAY EDGE LIGHTS
3'-6" SPACING
TERMINATING BAR
5'-0" SPACING
1000' BAR 5'-0" SPACING
OF 8 OUTER LIGHTS CENTERLINE BAR 3'-4 1/2"
SPACING
EL
EV
AT
ED
A
PP
R O
AC
H
L
IG
H
TS
'-0
'-0
'-0
'-0
SE
M
IF
LU
SH
L
IG
H
TS
(N
O
TE
15'-0"
75'-0" 75'-0"
STA 1+00
STA 2+00
C
EN
TE
R
LI
N E
BA
R
S
0' -0
" S
PA
C
IN
G
F
LA
SH
ER
S
70'-0"
GATE
GREEN/RED BI-DIRECTIONAL
RUNWAY THRESHOLD/END
LIGHT
NOTE 3
15'-0"
CL
40'-0"
10'-0"
MAX
40'-0"
10'-0"MAX
0'
-0 " 1
'-0
0' -0
RED SIDE ROW APPROACH
LIGHT
GREEN RUNWAY THRESHOLD
LIGHT
WHITE SEQUENCED FLASHING
LIGHT
WHITE APPROACH LIGHT
35'-0" 15'-0" 15'-0" 35'-0"
DRAWING NOTES - FIGURE 50A:
1. THE THRESHOLD AND THE APPROACH LIGHT SYSTEM UP TO AND INCLUDING STATION 9+00 ARE
IN-PAVEMENT IN PAVED OVERRUNS, AND ELEVATED IN NON-PAVED OVERRUNS.
2. FOR REFERENCE ONLY, RUNWAY END LIGHTS CONSIST OF 10 RED LIGHTS ARRANGED IN TWO GROUPS OF 5 LIGHTS. THE LIGHTS IN EACH GROUP MUST HAVE A UNIFORM SPACING OF 10'. THE OUTBOARD MOST LIGHT IN EACH GROUP MUST BE IN LINE WITH THE LINE OF THE RUNWAY EDGE LIGHTS ON THAT SIDE OF THE RUNWAY. THE GROUPS MUST BE LOCATED SYMMETRICALLY ABOUT, AND ON A LINE PERPENDICULAR TO, THE RUNWAY CENTERLINE WITHIN 10' OF THE END OF THE USABLE RUNWAY SURFACE. WHERE THEY ARE COLLOCATED, RUNWAY END LIGHTS MAY BE INCORPORATED INTO THE OPPOSITE END THRESHOLD
FIXTURES.
3. THE THRESHOLD BAR MAY BE “GATED” TO ALLEVIATE THE PROBLEM OF TAIL HOOK BOUNCE. THE THRESHOLD GATE IS ACCOMPLISHED BY ELIMINATING THOSE LIGHTS IN THE CENTER 70' PORTION
CENTERED ABOUT THE RUNWAY CENTERLINE.
LEGEND
UNI-DIRECTIONAL GREEN THRESHOLD LIGHT
BI-DIRECTIONAL THRESHOLD-RED/OBSCURED
RUNWAY END LIGHT (NOTE 1)
THRESHOLD LIGHT CIRCUIT
(NOTE 2)
EDGE LIGHT CIRCUIT
R1/R19
RUNWAY EDGE LIGHT
LA
N
D
IN
G T
H R
ES
H
O
LD
RUNWAY
CENTERLINE
NOTE 3
EDGE LIGHT CIRCUIT
#R1/R19
THRESHOLD CKT.
G
AT
E
AR
EA
FOR TAILHOOK OPERATIONS, LIGHTS IN
MIDDLE 70'-0" MAY BE OMITTED
DRAWING NOTES - FIGURE 4-5B:
1. THE BI-DIRECTIONAL RUNWAY END/THRESHOLD LIGHT MAY BE INSTALLED AS SEPARATE
UNI-DIRECTIONAL FIXTURES. THE BI-DIRECTIONAL FIXTURE MUST MEET THE PHOTOMETRICS FOR
THRESHOLD AND END LIGHTS AS INDICATED IN UFC 3-535-01.
2. CONTROL CIRCUITS FOR THRESHOLD REGULATOR MUST BE WIRED IN PARALLEL WITH EDGE
LIGHTING CONTROL CIRCUITS REGULATOR(S) SUCH THAT THRESHOLD LIGHTS ARE ENERGIZED
AND AT SAME INTENSITY AS RUNWAY EDGE LIGHTS.
3. WHERE THERE ARE AN EVEN NUMBER OF THRESHOLD BAR LIGHTS, THE TWO ADJACENT LIGHTS
ABOUT THE RUNWAY CENTERLINE MUST BE CONNECTED TO THE SAME CIRCUIT TO PROVIDE A
SYMMETRICAL LIGHTING PATTERN ON EACH SIDE OF THE RUNWAY CENTERLINE.
MOUNTING HARDWARE DETAILL12 SCALE: NTS
TOP VIEWG12 SCALE: NTS
TYPICAL HIGH INTENSITY ELEVATED APPROACH/THRESHOLD LIGHT 6-0" MAX.L11 SCALE: NTS
ALSF-1 APPROACH LIGHT SYSTEM CONFIGURATIONF6 SCALE: NTS (AIR FORCE)
WIRING DIAGRAMB1 SCALE: NTS (AIR FORCE)
HIGH INTENSITY THRESHOLD BAR
BI-DIRECTIONAL THRESHOLD-GREEN/YELLOW
RUNWAY END LIGHT (NOTE 1)
B
C
D
E
F
G
H
J
K
L
M
N
P
SU
BM
IT
TE
D B
Y:
C H
EC
KE
D B
Y:
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
IS
SU
E D
AT
E:
SI
ZE
M
AR
K
D
ES
C R
IP
TI
O N
D
AT
E
SHEET ID
SHEET OF 467
MI ANGB
ST
AT
E O
F M
IC
H
IG
AN
D
EP
AR
TM
EN
T
O F
TE
C
H N
O
LO
G Y, ST
AT
E
FA
C
IL
IT
IE
S
AD
M
IN
IS
TR
AT
IO
N D
ES
IG
N A
N D
C O
N
ST
R U
C
TI
O N
D
IV
IS
IO
N
LA
N C
IN
G
, M
IC
H
IG
AN
M
AN
AG
EM
EN
T, A N
D B
U D
E
5, AN
SI
D
M
EA
D
H U
N T, IN
C
D
EM
IN
G W
AY
M
ID
D
LE
TO
N , W
I
SE
LF
R
ID
G E
AI
R
N
AT
IO
N
AL
G
U
AR
D B
AS
E, M
IC
H
IG
AN
R
U N
W
AY
E N
C R
O
AC
H M
EN
T
SO
LU
TI
O
N
PR
O
JE
C
T #2
AI
R
FI
EL
D
IM
PR
O
VE
M
EN
TS
TA
SK
M C
C A
M
IT
IG
AT
E R
U N
W
AY
E N
C R
O
AC
H M
EN
T
Y
TY
PE
B -3
0% F
IN
AL
S U
BM
IT
TA
L
M
JR
D
LU
PA
B
D R
P
AI
R
FI
EL
D
E
LE
C
TR
IC
AL
D
ET
AI
LS
EA511
REMOTE CONTROL PANEL
INPUT POWER TO REGULATORS
LEGEND
AUXILIARY RELAY ASSEMBLY
WHITE APPROACH LIGHT
RED SIDE ROW APPROACH LIGHT
ISOLATION TRANSFORMER
WHITE SEQUENCED FLASHING LIGHT
TYPICAL CIRCUIT BREAKER PER NATIONAL
ELECTRICAL CODE (SIZE AND NUMBER OF POLES
DEPENDS ON PARTICULAR INSTALLATION)
TYPICAL CONSTANT CURRENT REGULATOR
(CCR) L-828 OR L-829
SSALR
CKT A
ALSF-1
CKT B
ALSF-1
CKT C
ALSF-1
CKT D
MASTER
TIMER ADJ
L-841
12345678911 1012131420 1516171819
FAA L-880 STYLE "B" SYSTEM (WITH TILT SWITCHES)
3 LAMPS PER LIGHT UNIT
300W, 6.6/6.6A ISOLATION TRANSFORMER (OR AS REOQUIRED BY
MANUFACTURER)
100W, 6.6/6.6A ISOLATION TRANSFORMER (OR AS REQUIRED BY
MANUFACTURER)
CONSOLIDATING HARNESS FROM MANUFACTURER
POWER LEADS WITH APPROPRIATE L-823 CONNECTORS,
USE L-824 TYPE C #6 (L-823 CONNECTOR KITS).
TILT SWITCH LEADS (USE MANUFACTURER SUPPLIED)5
PAPI LIGHT
UNIT
ASSEMBLY
MASTER
PAPI LIGHT
UNIT
ASSEMBLY
SLAVE
PAPI LIGHT
UNIT
ASSEMBLY
SLAVE
PAPI LIGHT
UNIT
ASSEMBLY
SLAVE
3 3 3 3
5 5 54 4
1 1 2 1 1 1 1 1 1
INCOMING POWER FEED 6.6 AMPS
CONSTANT CURRENT
INDICATES
PRIMARY
PLUG
INDICATES
SECONDARY
RECEPTACLE
INDICATES
SECONDARY
PLUG
INDICATES
PRIMARY
RECEPTACLE
INDICATES FIELD
WATERPROOF
CUSTOMER SPLICE
CONCRETE BASE
1" PVC WITH #4 GND
3/4" X 10'-0"
GROUND ROD
SECTIONAL VIEW
2" SCH 40 PVC
CONDUIT BETWEEN
PAPI LIGHT UNITS
ANCHOR ROD
AIM TOWARD
THRESHOLD
EXPANSION
JOINT (TYP)
EXOTHERMIC
CONNECTION
L-880 3-LAMP LIGHT UNIT
(TYP FOR 4 LIGHT UNITS
IN SYSTEM)
FRANGIBLE
COUPLING (TYP)
WATER-TIGHT
FLEXIBLE CONDUIT
BREAKABLE COUPLING AS
SPECIFIED BY PAPI MANUFACTURER
INTERNAL GROUND LUG
FINISHED
GRADE
5'-0"
LIGHT BASE, FAA
L-867, SIZE D
LIGHT
ELEVATION
AS SHOWN
ON CONTRACT
DRAWINGS
1'-0"
10'-0" 6"
ADJUST LEG
HEIGHT AS
REQUIRED
4' -0
" M
IN
EX
TE
N D
B
EL
O W
FR
O
ST
L
IN
E
IF
R
EQ
U
IR
ED
4"
2"
VARIES BY MANUFACTURER'S INSTALLATION DIAGRAM
2" TY
P
REINFORCEMENT WELDED WIRE FABRIC
DRAWING NOTES - FIGURE 65A:
1. EACH LIGHT UNIT MUST BE AIMED OUTWARD INTO THE
APPROACH ZONE ON A LINE PARALLEL TO THE RUNWAY
CENTERLINE WITHIN ±1/2 DEGREE.
2. THE BEAM CENTERS OF ALL LIGHT UNITS MUST BE WITHIN ±1" OF
HORIZONTAL PLANE.
3. THE FRONT FACE OF EACH LIGHT UNIT IN A BAR MUST BE
LOCATED ON A LINE PERPENDICULAR TO THE RUNWAY
CENTERLINE WITHIN A TOLERANCE OF ±1".
4. DIMENSIONS ARE APPROXIMATE AND MUST BE COORDINATED
WITH PAPI MANUFACTURER.
5. AIMING ANGLE AND LOCATION OF UNITS MUST BE INDICATED ON
CONTRACT DOCUMENTS.
CONCRETE
MOW PAD
CONCRETE
MOW PAD
N O
TE
4'-0" THICK CONCRETE SLAB WITH
LIGHT BROOM FINISH
PAPI
SUPPORT LEG
(TYP FOR 3)
PAPI
REFERENCE
POINT
PAPI OUTLINE
1" PVC WITH
GROUND WIRE
EXPANSION JOINT
2" SCH 40 PVC (TYP)
2" CONDUIT TO NEXT PAPI UNIT
2" CONDUIT TO NEXT PAPI UNIT
MOW PAD - 4" THICK
WITH WIRE MESH, 1/2"
CHAMFER
L-867D DEEP BASE CAN,
2'-0" DEEP
DUCT
SEAL
EXOTHERMIC
TEE-CONNECTION
3/4" X 10'-0" MIN
COPPERCLAD GROUND
ROD WITH EXOTHERMIC
TEE-CONNECTION5'-0"
2'-0" 8"
10'-0"
5'-0"
1'-0" MIN
SLIP-FITTER/RUBBER
GROMMET (TYP)
AIM TOWARD
THRESHOLD
DRAWING NOTES - FIGURE 65B:
#6 SOLID BARE COPPER
(AIR FORCE/ ARMY)
#4 STRANDED BARE COPPER
(NAVY)
TO NEXT PAPI
TO NEXT
PAPI
1. EACH LIGHT UNIT MUST BE AIMED OUTWARD INTO THE APPROACH ZONE ON A LINE PARALLEL TO THE
RUNWAY CENTERLINE WITHIN ±1/2 DEGREE.
2. THE BEAM CENTERS OF ALL LIGHT UNITS MUST BE WITHIN ±1" OF HORIZONTAL PLANE.
3. THE FRONT FACE OF EACH LIGHT UNIT IN A BAR MUST BE LOCATED ON A LINE PERPENDICULAR TO THE
RUNWAY CENTERLINE WITHIN A TOLERANCE OF ±1".
4. DIMENSIONS ARE APPROXIMATE AND MUST BE COORDINATED WITH PAPI MANUFACTURER.
5. AIMING ANGLE AND LOCATION OF UNITS MUST BE INDICATED ON CONTRACT DOCUMENTS.
RUNWAY CENTERLINE
CROWN
CALCULATIONS - PAPI 23
PAPI LIGHT ELEVATION
(D = ) * TAN (3°)
THRESHOLD CROSSING EL
THRESHOLD ELEVATION
THRESHOLD CROSSING HT
RUNWAY SLOPE (%) = VARIES
RUNWAY SLOPE DIRECTION
* PAPI IS SITED ON A RUNWAY END WITH A GLIDE SLOPE.
CENTERLINE
OF PAPI LIGHT
ELEVATION = 2422.06'
30'-0" 30'-0" 30'-0"
THRESHOLD CROSSING
HEIGHT = 49.99'
OBSTACLE CLEARANCE
SURFACE
4 STATUE MILE RADIUS
THRESHOLD
ELEVATION = 2419.71' STA 0+00
RUNWAY CENTERLINE
PAPI
(4 BOX)
EDGE OF
PAVEMENT
CLEXISTING ELEVATION = 2422.06' STA 09+09.00
R/W 23
PROPOSED
GLIDESLOPE
ANTENNA
STA 10+00
AIMING ANGLE
NORMAL APPROACH - 3.0 DEGREES
AIMING ANGLE 1° 50' - OBSTACLE CLEARANCE SURFACE
10°
300'-0"
909'-0"
125'-0" FOR 150'-0" WIDE RUNWAY
SCALE: NTS
PAPI ELEVATION
FLASH HEAD
PRIMARY
UNIT
SECONDARY
UNIT
TRIGGER SYNCHRONIZATION
AS REQUIRED BY MANUFACTURER
SERIES RUNWAY LIGHTING CIRCUIT
L-830 ISOLATION
TRANSFORMER
L-830
ISOLATION
TRANSFORMER
HIGH INTENSITY ALSF-1/SSALR WIRING DIAGRAMK14 SCALE: NTS
FAA L-880 STYLE B PAPI (CONSTANT CURRENT) SYSTEM WIRING DIAGRAMF14 SCALE: NTS
PAPI LIGHT HOUSING ELEVATIONA10 SCALE: NTS
PAPI LIGHT HOUSING - PLANH7 SCALE: NTS
L849I(L)RIEL SYSTEM SCHEMATIC WIRING DIAGRAMH1 SCALE: NTS
RUNWAY 23 OBSTACLE CLEARANCE SURFACESA1 SCALE: NTS
NOTE: USE MANUFACTURER SUPPLIED
WIRING DIAGRAM FOR SEQUENCE
FLASHERS
4' -0
6'-0"
AutoCAD SHX Text
UNIT A
AutoCAD SHX Text
UNIT B
AutoCAD SHX Text
UNIT C
AutoCAD SHX Text
UNIT D
B
C
D
E
F
G
H
J
K
L
M
N
P
SU
BM
IT
TE
D B
Y:
C H
EC
KE
D B
Y:
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
IS
SU
E D
AT
E:
SI
ZE
M
AR
K
D
ES
C R
IP
TI
O N
D
AT
E
SHEET ID
SHEET OF 467
MI ANGB
ST
AT
E O
F M
IC
H
IG
AN
D
EP
AR
TM
EN
T
O F
TE
C
H N
O
LO
G Y, ST
AT
E
FA
C
IL
IT
IE
S
AD
M
IN
IS
TR
AT
IO
N D
ES
IG
N A
N D
C O
N
ST
R U
C
TI
O N
D
IV
IS
IO
N
LA
N C
IN
G
, M
IC
H
IG
AN
M
AN
AG
EM
EN
T, A N
D B
U D
E
5, AN
SI
D
M
EA
D
H U
N T, IN
C
D
EM
IN
G W
AY
M
ID
D
LE
TO
N , W
I
SE
LF
R
ID
G E
AI
R
N
AT
IO
N
AL
G
U
AR
D B
AS
E, M
IC
H
IG
AN
R
U N
W
AY
E N
C R
O
AC
H M
EN
T
SO
LU
TI
O
N
PR
O
JE
C
T #2
AI
R
FI
EL
D
IM
PR
O
VE
M
EN
TS
TA
SK
M C
C A
M
IT
IG
AT
E R
U N
W
AY
E N
C R
O
AC
H M
EN
T
Y
TY
PE
B -3
0% F
IN
AL
S U
BM
IT
TA
L
M
JR
D
LU
PA
B
D R
P
AI
R
FI
EL
D
E
LE
C
TR
IC
AL
D
ET
AI
LS
EA512
L-867 SIZE B CLASS I LIGHT BASE W/ 3/8"
STEEL COVER (NOTE 3)
FLEXIBLE PVC
CONDUIT (TYP)
EMT CONDUIT PER
MANUFACTURER'S
REQUIREMENTS (TYP)
3/4" Ø X 10'-0" GROUND
ROD
TO R/W CKT TO REIL SLAVE UNIT
#4 BARE COPPER
2" (53mm) ELBOWS RGS
TO REIL MASTER UNIT
NOTE 2
EMT FLEXIBLE CONDUIT
PER MANUFACTURER'S
REQUIREMENTS (TYP)
3/4" Ø X 10'-0" GROUND
ROD
#4 BARE COPPER
EXOTHERMIC WELD
EXTERNAL GROUND LUG
GROUNDING CLAMP
GROUNDING CLAMP
3/4" SCH 40 PVC
EXOTHERMIC WELD
3/4" SCH 40 PVC
2" ELBOW RGS
FRANGIBLE COUPLING (TYP)
2" RGS COUPLING (TYP)
FRANGIBLE COUPLING (TYP)
2" RGS COUPLING (TYP)
DRAWING NOTES - FIGURE 67:
1. DIMENSIONS AND LAYOUT VARY WITH MANUFACTURER. INSTALL PER MANUFACTURER'S REQUIREMENTS.
2. DIMENSION OF CONCRETE FOUNDATION VARIES WITH EQUIPMENT SUPPLIED. DEPTH MUST BE 36" OR 6" (150mm) BELOW FROST LINE WHICHEVER IS GREATER.
3. L-867 BASE FOR MOUNTING L-830 ISOLATION TRANSFORMER MAY BE PART OF FOUNDATION OR MOUNTED
SEPARATELY.
4. WIRE PER MANUFACTURER'S REQUIREMENTS.
5. INCOMING POWER WIRING AND CONDUIT NOT INDICATED FOR CLARITY. POWER WIRING MAY ENTER L-867
LIGHT BASE IN A SEPARATE CONDUIT FROM THE SERIES CIRCUIT LIGHTING CABLES.
1'-8"
(TYP)
1'-6"
(TYP)
1'-8"
(TYP)
DRAIN CONDUIT
(NOTE 8)
NOTES 6 AND 7
#6 COUNTERPOISE WITH EXOTHERMIC
CONNECTION AS REQUIRED
#6
COUNTERPOISE
(TYP)
CIRCUIT ID
MARKER (TYP)
NOTES 6 AND 7
GROUND ROD
3/4" X 10'-0"
(TYP)
1' -8
(T
YP
1' -0
(T
YP
2'-0"
(TYP)
1'-0"
(TYP)
6" (T
YP
3/8 COVER PLATE AND NEOPRENE GASKET
REINFORCING
2" PVC MALE ADAPTER (TYP)
2" SCH 40 PVC CONDUIT (TYP)
L-867D, 1'-4" Ø X 2'-0" DP
CONCRETE
EXTERNAL GROUND
LUG CONNECTION
#6 COUNTERPOISE
2' -0
(T
YP
6"
1/
2"
1" M
AX
PLAN
A
74 SCALE: NTS
SECTION
DRAWING NOTES - FIGURE 74:
1. NUMBER OF JUNCTION CANS AND CONDUIT CONFIGURATIONS
VARY. SEE LAYOUT PLAN SHEETS FOR ORIENTATION.
2. CONDUITS WHICH ARE NOT USED IN THE PROJECT MUST BE
CAPPED 12" OUTSIDE OF PLAZA CONCRETE.
3. ORIENT PLAZA AS INDICATED ON LAYOUT PLAN SHEETS.
4. CONTRACTOR MUST PROVIDE A 2" DIA DOMED BRONZE
MARKER AT EACH JUNCTION CAN AS INDICATED. MARKER
MUST BE STAMPED WITH CIRCUIT IDENTIFICATION AS
INDICATED ON LAYOUT PLAN SHEETS.
5. INSTALL GROUND RODS AND GROUND LOOP AT ALL JUNCTION
CAN PLAZAS AS INDICATED. TWO GROUND RODS PER PLAZA
LOCATED AT OPPOSITE CORNERS MUST BE PROVIDED.
COUNTERPOISE MUST BE LOCATED NOMINALLY 12" BELOW
EXISTING GRADE.
6. CONTRACTOR MUST LABEL 2 ENDS OF EACH JUNCTION CAN
PLAZA (JCP) BY IMPRESSING THE JCP IDENTIFICATION
NUMBER INTO THE CONCRETE FOUNDATION DURING
PLACEMENT. LETTERS AND NUMBERS MUST BE 4" IN HEIGHT,
PROPORTIONAL IN WIDTH, AND HAVE A STROKE WIDTH OF 1/2"
AND 1/4" DEPTH.
7. SEE LAYOUT PLAN SHEETS FOR JCP IDENTIFICATION
NUMBERS.
8. DRAIN CONDUITS MUST BE PROVIDED WHERE INDICATED ON
THE LIGHTING AND SIGNAGE LAYOUT SHEETS. SEE FIGURE 76
FOR CONNECTION TO JUNCTION CANS.
REIL MASTER UNIT INSTALLATIONL15 SCALE: NTS
REIL SLAVE UNIT INSTALLATIONF16 SCALE: NTS
JUNCTION CAN PLAZA, TYPE AA11 SCALE: NTS (AIR FORCE ONLY)
SCALE: NTS
DRAWING NOTES
1. DO NOT CONNECT COUNTERPOISE TO THE TRANSFORMER BASE.
CONNECT TRANSFORMER BASE AND COUNTERPOISE TO SEPARATE
GROUND RODS.
2. SIGN PAD MUST HAVE A 1" CHAMFER ON ALL EXPOSED HORIZONTAL
EDGES. EXTEND PAD 36" CLEAR ON ALL SIDES OF SIGN. SLOPE THE
TOP SURFACE TO DRAIN AWAY FROM SIGN, APPROXIMATELY 1%
(1/8"/FT). THE TOP OF THE PAD MUST BE APPROXIMATELY 1" ABOVE
THE SURROUNDING GRADE.
3. MAXIMUM OVERALL SIGN LENGTH: SIZE 3 - 14'-2".
4. ONE TETHER AT EACH END OF THE SIGN IF SEPARATE SIGN MODULES
ARE CONNECTED TOGETHER WITHIN A CONTINUOUS FRAME.
5. THE FRANGIBILITY POINT MUST BE NO GREATER THAN 3" ABOVE THE
GRADE ADJACENT TO THE PAD.
6. SURROUNDING GRADE MUST SLOPE 1/4" PER FOOT AWAY FROM THE
PAD FOR 15'-0". SOD OR SEED AS REQUIRED.
7. PAD THICKNESS AND REINFORCING WILL VARY DEPENDING ON THE
LENGTH AND NUMBER OF SIGN MODULES INSTALLED AS WELL AS THE
WIND LOADING (JET BLAST) EXPECTED.
FLASH HEAD
PRIMARY
UNIT
SECONDARY
UNIT
TRIGGER SYNCHRONIZATION
AS REQUIRED BY MANUFACTURER
SERIES RUNWAY LIGHTING CIRCUIT
L-830 ISOLATION
TRANSFORMER
L-830
ISOLATION
TRANSFORMER
L849I(L)RIEL SYSTEM SCHEMATIC WIRING DIAGRAMH9 SCALE: NTS
6.
LENGTH=SIGN LENGTH+6.00'
3.00'
#4 BARS EQUALLY
SPACED 18" O.C.
REFER TO PLANS FOR STATION AND OFFSET DISTANCE
RUNWAY GUIDANCE SIGN
1.5'
1.
OVERALL MOUNTING HEIGHT:
SIZE 3 - 3'-0" TO 3'-6"
SIZE 4 - 4'-6" TO 5'-0"
REINFORCING (NOTE 7)
STAINLESS
STEEL
EXPANSION
ANCHOR BOLT
(TYP.)
COMPACTED
SUBGRADE OR
CRUSHED STONE
LAYER FRANGIBLE
COUPLING (TYP.)
NOTE 4
NOTE 5
3"
REINFORCED CONCRETE
SIGN PAD (NOTE 2)
2"
MAX
3/4" X 10'-0"
COPPER-CLAD
STEEL GROUND ROD
3.00'
1.50'
#6 SOLID COPPER
COUNTERPOISE
(SEE NOTE 1)
#6 SOLID COPPER
COUNTERPOISE
(SEE NOTE 1)
FINISHED GRADE
(NOTE 6)
L-867, CLASS I TRANSFORMER
BASE, SIZE B, 1'-0" Ø, 2'-0"
DEEP WITH 3/8" GALVANIZED
STEEL COVER PLATE
L-867 CLASS 1A, SIGN
BASE, 1'-0" Ø X 3" DEEP
2" SCH. 40
PVC
SEE POWER LEG
MOUNTING DETAIL ON
SHEET EA513
6-#5 VERTICAL
BARS EQUALLY
SPACED
6-#4 VERTICAL
BARS EQUALLY
SPACED
#4 TIES EQUALLY
SPACED 1.0' O.C
6"
RDR GUIDANCE SIGN DETAILA3 SCALE: NTS
2" PVC DRAIN
CONNECTED TO
UNDERDRAIN SYSTEM
3' -2
.5
1.00'
B
C
D
E
F
G
H
J
K
L
M
N
P
SU
BM
IT
TE
D B
Y:
C H
EC
KE
D B
Y:
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
IS
SU
E D
AT
E:
SI
ZE
M
AR
K
D
ES
C R
IP
TI
O N
D
AT
E
SHEET ID
SHEET OF 467
MI ANGB
ST
AT
E O
F M
IC
H
IG
AN
D
EP
AR
TM
EN
T
O F
TE
C
H N
O
LO
G Y, ST
AT
E
FA
C
IL
IT
IE
S
AD
M
IN
IS
TR
AT
IO
N D
ES
IG
N A
N D
C O
N
ST
R U
C
TI
O N
D
IV
IS
IO
N
LA
N C
IN
G
, M
IC
H
IG
AN
M
AN
AG
EM
EN
T, A N
D B
U D
E
5, AN
SI
D
M
EA
D
H U
N T, IN
C
D
EM
IN
G W
AY
M
ID
D
LE
TO
N , W
I
SE
LF
R
ID
G E
AI
R
N
AT
IO
N
AL
G
U
AR
D B
AS
E, M
IC
H
IG
AN
R
U N
W
AY
E N
C R
O
AC
H M
EN
T
SO
LU
TI
O
N
PR
O
JE
C
T #2
AI
R
FI
EL
D
IM
PR
O
VE
M
EN
TS
TA
SK
M C
C A
M
IT
IG
AT
E R
U N
W
AY
E N
C R
O
AC
H M
EN
T
Y
TY
PE
B -3
0% F
IN
AL
S U
BM
IT
TA
L
M
JR
D
LU
PA
B
D R
P
AI
R
FI
EL
D
E
LE
C
TR
IC
AL
D
ET
AI
LS
EA513
2" SCH 40 PVC TEE OR 90
2" SCH 40 PVC DRAIN (TYP)
2" TO 1 1/2" REDUCING
BUSHING
LIGHTBASE OR JUNCTION CAN (TYP)
DRAWING NOTES - FIGURE 76:
1. SEE LAYOUT PLAN SHEETS FOR LOCATION OF DRAIN CONDUITS.
2. SLOPE DRAIN CONDUITS 1/8" PER FOOT MINIMUM TOWARD DRAINAGE STRUCTURES.
3. PENETRATE INLET/MANHOLE WITH DRAIN CONDUIT ABOVE STORM SEWER PIPES WHERE POSSIBLE
WHILE MAINTAINING SLOPE REQUIREMENT.
4. SEAL ENTRY AROUND DRAIN CONDUIT AT THE INLET/MANHOLE WITH COMPATIBLE NON-SHRINK
GROUT.
TOP SECTION
OF MANHOLE
1'-0" X 6" X 1/4" (MIN) SEE
'GROUND BUS DETAIL'
MINIMUM #6
BARE STRANDED
GROUND FOR CONSTANT
VOLTAGE CIRCUITS
#4 BARE STRANDED
GROUND
3/4" X 10'-0" GROUND
ROD
BOTTOM SECTION
OF MANHOLE
TO METALLIC
CABLE RACK
SEAL GROUND ROD
OPENING P-605
FACTORY INSTALLED GROUND
LUG ON COVER FRAME
#4 BARE STRANDED GROUND TO
MANHOLE COVER FRAME
1' -0
6"
#4 BARE
STRANDED GROUND
(TO COVER FRAME)
1'-0" X 6" X 1/4" MIN GROUND BUS
#6 TW,
GREEN GROUND
(TO CONDUIT)
OFFSET INSULATOR MOUNT
#4 BARE STRANDED GROUND
(TO GROUND ROD)
INSIDE MANHOLE WALL
1/2"
MIN
NOTE 1
DRAWING NOTES - FIGURE 80A:
1. ALL CONDUITS THAT CONTAIN COPPER CABLES FOR CONSTANT VOLTAGE CIRCUITS MUST BE
EQUIPPED WITH A MINIMUM #6 (16 SQUARE mm), TW GREEN GROUND WIRE. ALL CONDUITS
THAT ARE EMPTY MUST NOT CONTAIN A GROUND WIRE.
2. GROUND ALL METALLIC PARTS OF THE MANHOLE WITH A #4 (25 SQUARE mm) BARE STRANDED
GROUND WIRE.
3. THE CONTRACTOR MUST INSTALL A 200 LB POLYPROPYLENE PULL ROPE/STRING IN EACH DUCT
AND CONDUIT INSTALLED AND PLUG OR CAP THE DUCT. THE ROPE MUST BE SECURELY
ATTACHED TO THE PULL IRON IN EACH MANHOLE, OR A STAKE WHERE THE DUCT TERMINATES
UNDERGROUND.
4. ALL MANHOLES MUST BE INSTALLED AS INDICATED ON THE PLANS. COORDINATE FINAL
LOCATION WITH GRADING AND DRAINAGE PLANS. WHEN EXTENDING EXISTING DUCT TO NEW
MANHOLE, PUT MANHOLE IN LINE WITH EXISTING DUCT WHEN POSSIBLE. MANHOLES MUST NOT
BE INSTALLED IN DITCHES, DRAINAGE SWALES OR WHERE WATER WILL POND ON TOP OF THE
MANHOLE.
5. ALL PVC CONDUIT AND FITTINGS MUST BE SCHEDULE 40 AND MUST BE U.L. LISTED.
6. PVC PLUGS MUST BE INSTALLED IN EACH EMPTY SLEEVE AND DUCT.
7. PROVIDE PULLING IRONS ON ALL WALLS OPPOSITE CONDUIT ENTRY POINTS.
8. ALL WALL REINFORCEMENT (LOOP AND VERTICAL) AFFECTED BY DUCTWORK MUST BE
RELOCATED ON EITHER SIDE OF THE DUCT AND DETAILED IN THE SUBMITTAL.
9. THE CONTRACTOR MUST SUBMIT SHOP DRAWINGS SHOWING ALL REINFORCING STEEL AND
OTHER CONSTRUCTION DETAILS (SHIP-LAP JOINT, ETC.) PRIOR TO FABRICATION.
10. EACH DUCT CROSSING UNDER PAVEMENT MUST BE LOCATED AND DIMENSIONED ON THE
RECORD DRAWINGS, ACCURATE TO 0.5' (150mm). THE ENTRANCE AND EXIT FROM UNDER THE
PAVEMENT MUST BE MARKED WITH AN EMBEDDED ID MARKER AND STAMPED WITH THE DUCT
BANK NUMBER.
1'-2" HORIZONTAL MEMBER
LAY CABLES FLAT ON RACK AND
TIE EACH CABLE TO RACK WITH
NYLON TIE. INSTALL ADDITIONAL
CABLE TAG AT CENTER POINT OF
MANHOLE WALL
STAINLESS STEEL
EXPANSION ANCHORS
PER MANUFACTURES'
RECOMMENDATIONS
INSIDE WALL OF MANHOLE
3' -0
1"
NOTE 1
8" (T
YP
2" (T
YP
DRAWING NOTES - FIGURE 80B:
1. THE CABLE RACKING SYSTEM MUST BE RATED FOR 300 LBS. CABLE RACKS MUST
BE PLACED ON ALL MANHOLE WALLS WHETHER CURRENTLY USED OR NOT.
CABLES MUST BE TIED TO RACKS USING CABLE TIES.
2. GROUND ALL METALLIC PARTS OF THE MANHOLE WITH A #4 BARE STRANDED
GROUND WIRE.
WELD ALL
AROUND
INSTALL FLUSH +0,
-1/16"
3/ 8"
TE
XT
(T
YP
1/ 2"
(T
YP
1/2"
2" Ø
1/
8" M
IN
2"
3/8" 1/ 4" 1/
2"
1/ 4"
3/ 4"
1/ 8"
ID TEXT (TYPICAL)
PLAN
COMPLETE UNIT
YELLOW BRASS
FINISHED
SURFACE
SECTION A
SECTION
SCALE: NTS
A 80C
DRAWING NOTES - FIGURE 80C:
1. PROVIDE A BRASS SURVEY MARKER WITH ID TEXT STAMPED INTO IT FOR EACH AIRFIELD
LIGHTING MANHOLE.
DRAINS FOR JUNCTION CANSL16 SCALE: NTS (AIR FORCE ONLY)
GROUND BUS DETAILA15 SCALE: NTS
CABLE RACK OPTION DETAILL11 SCALE: NTS
BRASS SURVEY MARKER DETAILE10 SCALE: NTS
#6 GREEN INSULATED GROUND
INTERNAL GROUND LUG (NOTE 1)
L-858 GUIDANCE SIGN
FRANGIBLE COUPLING
NOTE 3
6" TRANSFORMER STAND
NEOPRENE GROMMET
WHERE SPECIFIED
L-823, TYPE II, CLASS A, STYLE 8
SECONDARY CONNECTOR
COPPER CONNECTOR. ONE PER
CONDUCTOR, BOLTED TO
INTERNAL GROUND LUG
CABLE CLAMP
NEOPRENE GROMMET
L-867 CLASS 1A, SIGN
BASE, 1'-0" Ø X 3" DEEP
REINFORCEMENT
(BAR CAGE
DETAIL)
L-823, CONNECTOR
#6 GREEN INSULATED
PRIMARY CIRCUIT SAFETY
GROUND (NOTE 2)
2" THREADED HUB WHERE
REQUIRED
3"
#6 SOLID BARE
COPPER TO
3/4" X 10'-0"
GROUND ROD
ATTACH CABLE TO
GROUND LUG
(NOTE 4)
1/2" EXPANSION JOINT
FILLER MATERIAL
EXOTHERMIC
WELD
DRAWING NOTES
1. SEE SPECIFICATIONS FOR ADDITIONAL GROUNDING REQUIREMENTS INSIDE THE SIGN.
2. GROUNDING CONDUCTORS MUST BE THWN-2 OR XHHW-2.
3. PROVIDE BOTTOM DRAIN TO UNDERDRAIN SYSTEM.
SIGN BASE POWER LEG MOUNTING DETAILJ1 SCALE: NTS
MAINTAIN MIN 3"
COVER ON REBAR
TIE BAR CAGE
6 - #5 (#15M)
REBAR, LENGTH
AS REQUIRED #4 (#13M) REBAR
TIES
@ 6"± OC
STD 90° HOOK
LIGHT BASE BAR CAGE DETAILF6 SCALE: NTS
LED ARRESTING GEAR MARKER (FAA L-858B)
FAA SIZE 4, STYLE 3, CLASS 1, MODE 3
INTEGRAL LAMP SHORTING SWITCH
ACTUAL DIMENSIONS, BOLT
PATTERN AND CONNECTIONS PER THE MFR.
SEE ELECTRICAL
CONNECTION DETAIL
SIGN BASE AND INSTALLATION MUST BE IN
ACCORDANCE WITH FAA AC 150/5345-18.
VERIFY ARRESTING GEAR MARKER
REQUIREMENTS WITH AIR NATIONAL GUARD.
1.)
2.)
NO…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .