LIMITED ASBESTOS AND LEAD CONTAINING PAINT

PRE-ALTERATION INSPECTION REPORT

Project ID: 081517-BD41-Egress

Sampling Date: August 15 and 16, 2017

Sampling Location: DFC BD 41 1st Floor Warehouse

Inspector/Cert#: Andi Driessner CDPHE# 20945

Project Scope: Project to install proper egress within the 1st floor warehouse.

BACKGROUND

This limited pre-alteration inspection was completed prior to a renovation project within the federally owned and occupied Building 41 (BD 41) located on the Denver Federal Center with the objective of assessing all building materials set for disturbance specific to the project listed above for asbestos content and lead-containing paint identification.

BD41 is a 498,389 square foot, two-story commercial structure built in 1941 with a brick and wood frame structure; primary use of the building is office space. Prior renovations are vast and full details are unknown. This assessment is limited to three 1st floor warehouse areas: the Central Stair, South Stair and West Egress (detailed in map below), and the northern exterior of BD 41. All other areas and materials not listed in this report are excluded from this survey.

LIMITED ASBESTOS INSPECTION

A limited asbestos inspection was completed in accordance with all applicable local, state, and federal regulations, including but not limited to Colorado Department of Public Health and Environment Air Quality Control Commission Regulation No. 8, Part B Asbestos (5 CCR 1001-10, Part B), U.S. Environmental Protection Agency (EPA) Asbestos Hazard Emergency Response Act (AHERA) sampling protocols (40 CFR

763.86 et seq.), EPA National Emission Standards for Hazardous Air Pollutants (NESHAP)(40 CFR 61 Subpart M), and Occupational Safety and Health Administration (OSHA) asbestos regulations (29 CFR 1910.1001 and 29 CFR 1926.1101) in effect at the time of inspection.

The number of samples taken for each homogeneous area corresponds to the specific material type and quantity to be disturbed. Any further renovation activities that may disturb suspect materials other than those identified for this survey, including larger areas of materials already sampled for this survey, may require further testing and should be completed only after additional sampling of such materials has been conducted. This is not an abatement scope of work nor should it be used as such.

Please contact OFM if further testing is needed.

Samples collected for asbestos analysis were obtained by qualified and appropriately certified/licensed personnel utilizing proper safety measures such as wetting the material prior to sampling, cleaning up the area by wet wiping any resulting residual debris, and wearing proper personal protective equipment, as needed. In order to be certain of sampling the entire thickness of a material, coring tools and knives were utilized to penetrate all layers of a material. All collected samples were then placed in appropriately labeled airtight containers for shipment to the laboratory for analysis under chain of custody protocols.

Nineteen bulk samples, encompassing a total of twenty-eight homogeneous areas, were collected and submitted for bulk sample analysis at EMSL Analytical, Inc. (EMSL).

EMSL is an American Industrial Hygiene Association (AIHA) and National Institute of Standards and Technology (NIST) National Voluntary Laboratory Accreditation Program (NVLAP) laboratory accredited to perform asbestos analytical services. All materials were analyzed by PLM (Polarized Light Microscopy) in accordance with the EPA 600/R- 93/116 method. Multi-layered samples were analyzed by individual layers. A total of forty-seven analyses were conducted accounting for multi-layered samples.

According to OSHA, EPA AHERA, and the EPA National Emission Standards for Hazardous Air Pollutants (NESHAP) criteria, asbestos-containing materials are defined as materials which have at least one (1) sample containing an asbestos content of more than one (1) percent (%) from a homogeneous material area set of samples and all bulk samples from a homogeneous area must be found to contain one (1)% or less of asbestos in order to be classified as non-asbestos-containing. OSHA guidelines apply during the disturbance of materials that contain asbestos detected in any amount;

therefore, materials that were identified as “Trace” (less than one [1] % ACM) by analysis should be accounted for during the planning process for renovation activities.

LEAD-CONTAINING PAINT IDENTIFICATION

Lead-containing paint identification was completed following procedures outlined in the EPA Lead-Based Paint Activities (40 CFR 745 Subpart L), U.S. Housing and Urban Development (HUD) Lead-Based Paint Poisoning Prevention in Certain Residential Structures (24 CFR 35), HUD Guidelines for the Evaluation and Control of Lead-Based Paint Hazards in Housing, OSHA lead regulations (29 CFR 1910.1025 and 29 CFR 1926.62) and the Federal Management Regulation- Real Property, Safety and Environmental Management (41 CFR 102-80.30) in effect at the time of inspection. It should be noted that EPA, HUD, and state regulations don’t apply to non-child occupied commercial or public buildings and have been referenced here as guidance only.

Samples collected for lead paint chip analysis were obtained in a manner consistent with the above referenced regulations by qualified individuals. One representative paint chip sample from each homogenous area, grouped by component type, substrate, visible color, and texture was collected from all coated and painted substrates identified for disturbance during this project. Any materials not identified in this report are excluded from this assessment and would need to be tested or assumed as lead-containing for the project to proceed.

Nine lead paint chip samples were collected and submitted under chain-of-custody protocols for flame atomic absorption spectroscopy (FAAS) analysis via EPA Method SW 846 3050B/7000B to EMSL Analytical, Inc., a laboratory accredited by the EPA National Lead Laboratory Accreditation Program (NLLAP) and AIHA Environmental Lead Laboratory Accreditation Program (ELLAP), and participating in the AIHA Environmental Lead Proficiency Analytical Testing (ELPAT) program. Under the OSHA Lead in Construction Standard, all detectable levels of lead in paints and coatings are regulated, not just the EPA/HUD definition of lead based paint (LBP) of 0.5% by weight.

FINDINGS/CONCLUSIONS

Table 1 below lists all materials sampled, homogeneous areas included, and asbestos results for each sample. Laboratory analysis indicated that asbestos was found in two of the test samples. One type of non-friable asbestos-containing material was identified, the beige 12x12 floor tile in the Central Stair east corridor area #3, partial floor.

Any ACM identified for disturbance or removal in this survey must be removed in accordance with local, state and federal regulations. The removal must be performed by a certified abatement contractor or otherwise appropriately trained. As the disturbance of ACM is less than the trigger levels for Regulation No. 8, being 160 square feet or 260 linear, this activity will fall under the OSHA Asbestos in Construction Standard, 29 CFR

1926.1101. The OSHA defined Competent Person for whomever is completing the work must make the determination of the appropriate class this work will fall into and must comply with all requirements sets forth in 29 CFR 1926.1101. All other materials identified are non-asbestos containing and renovation activities for such may proceed unless other hazards have been identified.

Table 2 below lists lead paint chip sample results for all materials sampled, represented areas included. Laboratory analysis indicated that detectable levels of lead were found in seven of the test samples. All painted surfaces set for disturbance within the West Egress, South Stair and northern exterior area are lead-containing. For the Central Stair, the multilayered paint over brick in Room 107 is lead-containing, although the white painted drywall and plywood walls within the east corridor area #3 did not contain detectable levels for lead. See Table 2 for detailed descriptions and lead concentrations. The OSHA Lead in Construction Standard (29 CFR 1926.62) applies to disturbance of paints or coatings with any detectable concentration of lead. Disturbance includes sanding, burning, welding, scraping, or otherwise impacting. Any project that disturbs assumed or confirmed lead-containing paint must comply with this standard.

Lead-containing paint that is intact and in good condition need not be abated unless required for alteration or demolition and may be removed intact via component removal.

All lead containing debris and lead bearing waste shall be double bagged in 6-millimeter, labeled polyethylene bags, containerized, and transported and properly disposed of off-site at an appropriate facility. The contractor preforming the work shall be responsible for the proper characterization and management of lead bearing waste or debris in accordance with applicable federal, state, and local hazardous waste regulations. Lead bearing waste or debris shall be assumed to be hazardous waste due to the characteristic of toxicity (Lead, EPA Waste Code D008) or have representative waste stream samples submitted to an accredited analytical laboratory for analysis via EPA Method SW-846 Test Method 1311: Toxicity Characteristic Leaching Procedure (TCLP). As applicable, the waste characterization and manifest documentation shall be provided to GSA as part of the deliverable.

Please attach this report to the scope of work for this project. Contact OFM for removal method approval, clearance perimeters, if required, with any questions regarding these results, or if other hazards have been encountered or are suspected in the project area.

Robert V. Smith, CHMM Andi Driessner GSA Regional Industrial Hygienist Industrial Hygienist, Certified BI-Asbestos Robertv.smith@gsa.gov Andrea.driessner@gsa.gov 720-275-7459 720-309-5024 mailto:Robertv.smith@gsa.gov mailto:Andrea.driessner@gsa.gov

Table 1: Asbestos Bulk Sample Results

Sample No.

Homogeneous Material Area A

Area Represented

Sample Location Asb % Friable Cond. B

081517-

BD41-

Egress-

FT1-1

HA# 1

Beige 12x12 floor tile

HA# 2

Yellow mastic

BD 41, central stair, east corridor storage area #3, partial floor

West end storage, by west storage Floor tile:

2% Chrysotile

Mastic:

ND

No Good

081517-

BD41-

Egress-

FT1-2

West end storage, by west storage No Good

081517-

BD41-

Egress-

CT1-1

HA# 3

4x2 faux 2x2 ceiling tile

BD 41, central stair, east corridor storage area #3, ceiling

Southwest entrance ceiling

ND Yes Good

081517-

BD41-

Egress-

CT2-1

HA# 4

2x4 streak & pinhole ceiling tile

BD 41, central stair, east corridor storage area #3 and Rm 107, lodge and bank hallway, partial ceiling

East side ceiling ND Yes Good

081517-

BD41-

Egress-

CT3-1

HA# 5

2x4 streaked ceiling tile

BD 41, central stair, east corridor storage area #3 and Rm 107, lodge and bank hallway, partial ceiling

East side ceiling ND Yes Good

081517-

BD41-

Egress-

CT4-1

HA# 6

2x4 pinholed ceiling tile

BD 41, central stair, east corridor storage area #3 and Rm 107, lodge and bank hallway, partial ceiling

East side ceiling ND Yes Good

Table 1: Asbestos Bulk Sample Results

Sample No.

Homogeneous Material Area A

Area Represented

Sample Location Asb % Friable Cond. B

081517-

BD41-

Egress-

DWT2-1

HA# 7

Light orange peel texture

HA# 8

Drywall

BD 41, central stair, east corridor storage area #3, partial walls

East wall, mid room by cage ND Yes Good

081517-

BD41-

Egress-

DWT2-2

East wall, mid room by cage ND Yes Good

081517-

BD41-

Egress-

DWT2-3

East wall, mid room by cage ND Yes Good

081517-

BD41-

Egress-

WBM1-1 HA# 9

Black residual wallboard mastic

BD 41, central stair, east corridor storage area #3, wall base

East wall, mid room, at base ND No Good

081517-

BD41-

Egress-

WBM1-2

East wall, mid room, at base ND No Good

081517-

BD41-

Egress-

WBM2-1 HA# 10

Tan residual wallboard mastic

BD 41, central stair, east corridor storage area #3, wall base

East wall, mid room, at base ND No Good

081517-

BD41-

Egress-

WBM2-2

East wall, mid room, at base ND No Good

Table 1: Asbestos Bulk Sample Results

Sample No.

Homogeneous Material Area A

Area Represented

Sample Location Asb % Friable Cond. B

081517-

BD41-

Egress-

CM1-1

HA# 11

Brown carpet mastic

BD 41, central stair, east corridor storage area #3, Rm 107 floor under green carpet squares

Rm 107 floor, near south entrance threshold

ND No Good

081517-

BD41-

Egress-

CBM3-1

HA# 12

4” black cove base

HA# 13

Tan mastic

BD 41, central stair, east corridor storage area #3, Rm 107 wall base

North wall, northeast corner at base ND No Good

081517-

BD41-

Egress-

CBM3-2

North wall, northeast corner at base ND No Good

081517-

BD41-

Egress-

RB1-1

HA# 14

Rubber bumper

BD 41, west exterior concrete wall

West exterior concrete partial wall ND No Good

081517-

BD41-

Egress-

DWT1-1

HA# 15

Light orange peel texture

HA# 16

Tape

HA# 17

Joint compound

HA# 18

Drywall

BD 41, west egress, corridor

102 and 103, partial walls, above plywood

Corridor 103, southeast wall 10’ from main entrance

ND Yes Good

081517-

BD41-

Egress-

DWT1-2

Corridor 103, southeast wall 30’ from main entrance

ND Yes Good

081517-

BD41-

Egress-

DWT1-3

Corridor 103, southeast wall 20’ from main entrance

ND Yes Good

Table 1: Asbestos Bulk Sample Results

Sample No.

Homogeneous Material Area A

Area Represented

Sample Location Asb % Friable Cond. B

081517-

BD41-

Egress-

PL1-1

HA# 19

Painted plaster

BD 41, west egress, corridor 102, walls over brick

Corridor 102, east wall by roll up ND Yes Good

081517-

BD41-

Egress-

PL1-2

Corridor 102, east wall by roll up ND Yes Good

081517-

BD41-

Egress-

PL1-3

Corridor 102, east wall by roll up ND Yes Good

081517-

BD41-

Egress-

CM2-1 HA# 20

Tan and white carpet mastic

BD 41, south stairwell, stairs

South stairwell, bottom stairs, 4th step up

ND No Good

081517-

BD41-

Egress-

CM2-2

South stairwell, 2nd stair set, 3rd step up

ND No Good

081517-

BD41-

Egress-

FT2-1

HA# 21

Beige floor tile

HA# 22

Yellow mastic

HA# 23

Black mastic

HA# 24

Black mastic

BD 41, south stairwell, top of top landing, floors under carpet

South stairwell, top landing at stair threshold

ND No Good

081517-

BD41-

Egress-

FT2-2

South stairwell, top landing at stair threshold

ND No Good

081517-

BD41-

Egress- L1-1

HA# 25

Gray leveler

BD 41, south stairwell, top of top landing, under CBM4

South stairwell, top landing under

CMB4-1

ND No Good

Table 1: Asbestos Bulk Sample Results

Sample No.

Homogeneous Material Area A

Area Represented

Sample Location Asb % Friable Cond. B

081517-

BD41-

Egress-

CBM4-1

HA# 26

4” black cove base

HA# 27

Cream mastic

BD 41, south stairwell, top of top landing wall base

South stairwell, southeast wall, wall base at stairs

ND No Good

081517-

BD41-

Egress-

CBM4-2

South stairwell, southeast wall, wall base at stairs

ND No Good

081517-

BD41-

Egress-

TF1-1

HA# 28

Tar felt

BD 41, south stairwell, top of top landing, floor under FT2

South stairwell, top landing, under

FT2-1

ND Yes Good

A = Homogeneous material descriptions include an alpha numeric descriptor delineating the various homogeneous area/materials with a physical description of the material.

B = EPA AHERA Asbestos Assessment Hazard Rankings (condition and friability).

Table 2: Lead Paint Chip Results

Sample No.

Component/ Substrate Paint Color Area

Represented Sample Location

Lead Content (% by wt.)

Pb1 Brick wall White, tan, and green

Central Stair, Room 107 east wall

Room 107, east wall 0.13%

Pb3 Wood frame Brown Exterior wood framing

Exterior loading dock, above roll up 24%

Pb4 Plywood wall White

Central Stair, East corridor storage area

#3 walls

Outside Room 1124, wall BRL*

Pb6 Plaster wall White West Egress, Corridor 102, walls

Corridor 102, wall 0.019%

Pb7 Metal bollard

Brown, yellow, and red

Exterior metal bollards

Exterior metal bollard outside loading dock

11%

Pb8 Metal handrail

Gray, black, yellow, and red

South Stairwell handrails

South stairwell, bottom handrail 0.53%

Pb9 Wood wall Green South stairwell wood walls

South stairwell, wall 0.12%

Pb10 Brick wall White and green

South stairwell brick walls

South stairwell, wall 0.30%

Pb11 Drywall wall Off-white

Central Stair, East corridor storage area #3 drywall walls

East corridor storage area

#3 wall

BRL*

*BRL = Below Reporting Limit ** Samples Pb2 and Pb5 had insufficient sample size and were discluded from analysis.

Map of project and sample locations- Central Stair

= FT1

= CT1

= CT2

= CT3

= CT4

= DWT2

= WBM1

= WBM2

= CM1

= CBM3

= RB1

Map of project and sample locations- Central Stair

= FT1

Map of project and sample locations- West Egress

= DWT1

Map of project and sample locations- West Egress

= PL1

= CM2

= FT2

= L1

= CBM4

= TF1

Map of project and sample locations- South Stair

EMSL Analytical, Inc.

1010 Yuma Street Denver, CO 80204

Tel/Fax: (303) 740-5700 / (303) 741-1400 http://www.EMSL.com / denverlab@emsl.com

221705673EMSL Order:

Customer ID: GSAL42

Customer PO:

Project ID:

Attention: Phone:Robert Smith (720) 275-7459

Fax:GSA

Received Date:Denver Federal Center Bldg 08/16/2017 4:35 PM

Analysis Date:BLDG 41 PO Box 25006 08/23/2017

Collected Date:Lakewood, CO 80225 08/15/2017

Project: 081517-BD41-Egress

Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized

Light Microscopy

Sample Description Appearance % Fibrous % Non-Fibrous

Non-Asbestos Asbestos

% Type

FT1-1-Floor Tile

221705673-0001

2% ChrysotileNon-fibrous (Other)98%Beige

Non-Fibrous

Homogeneous

Beige 12x12 w/ yellow mastic E. corridor

Storage Rm3

HA: 1

FT1-1-Mastic

221705673-0001A

None DetectedNon-fibrous (Other)100%Yellow

Non-Fibrous

Homogeneous

Beige 12x12 w/ yellow mastic E. corridor

Storage Rm3

HA: 1

FT1-2-Floor Tile

221705673-0002

2% ChrysotileNon-fibrous (Other)98%Beige

Non-Fibrous

Homogeneous

Beige 12x12 w/ yellow mastic E. corridor

Storage Rm3

HA: 1

FT1-2-Mastic

221705673-0002A

None DetectedNon-fibrous (Other)100%Yellow

Non-Fibrous

Homogeneous

Beige 12x12 w/ yellow mastic E. corridor

Storage Rm3

HA: 1

CT1-1

221705673-0003

None DetectedNon-fibrous (Other)20%Cellulose

Glass

60%

20%

Gray/White

Fibrous

Homogeneous

4x2 faux 2x2 CT E.

Corridor Storage Rm

HA: 2

CT2-1

221705673-0004

None DetectedNon-fibrous (Other)20%Cellulose

Min. Wool

50%

30%

Gray/White

Fibrous

Homogeneous

2x4 pinhole & streak main CT E. Corridor

Storage Rm 3

HA: 3

CT3-1

221705673-0005

None DetectedNon-fibrous (Other)20%Cellulose

Glass

50%

30%

Gray/White

Fibrous

Homogeneous

2x4 streaked CT E.

Corridor Storage Rm

HA: 4

CT4-1

221705673-0006

None DetectedNon-fibrous (Other)10%Cellulose

Glass

70%

20%

Tan/White

Fibrous

Homogeneous

2x4 pinhole CT E.

Corridor Storage Rm

HA: 5

DWT2-1-Texture

221705673-0007

None DetectedNon-fibrous (Other)100%White

Non-Fibrous

Homogeneous

Light OPT over drywall E. Corridor

Storage RM 3

Inseparable paint / coating layer included in analysis

HA: 6

DWT2-1-Drywall

221705673-0007A

None DetectedGypsum

Non-fibrous (Other)

50%

40%

Cellulose10%Brown/White

Fibrous

Homogeneous

Light OPT over drywall E. Corridor

Storage RM 3

HA: 6

DWT2-2

221705673-0008

None DetectedGypsum

Non-fibrous (Other)

50%

40%

Cellulose10%Brown/White

Fibrous

Homogeneous

Light OPT over drywall E. Corridor

Storage RM 3

Inseparable paint / coating layer included in analysis

HA: 6

WBM1-1

221705673-0009

None DetectedNon-fibrous (Other)100%White/Black

Fibrous

Homogeneous

Black WB mastic residual E. Corridor

Storage Rm 3

HA: 7

Initial report from: 08/23/2017 20:45:50

Page 1 of 4ASB_PLM_0008_0001 - 1.78 Printed: 8/23/2017 6:45 PM

Tel/Fax: (303) 740-5700 / (303) 741-1400 http://www.EMSL.com / denverlab@emsl.com

221705673EMSL Order:

Customer ID: GSAL42

Customer PO:

Project ID:

Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized

Light Microscopy

Sample Description Appearance % Fibrous % Non-Fibrous

Non-Asbestos Asbestos

% Type

WBM1-2

221705673-0010

None DetectedNon-fibrous (Other)100%White/Black

Fibrous

Homogeneous

Black WB mastic residual E. Corridor

Storage Rm 3

HA: 7

WBM2-1

221705673-0011

None DetectedNon-fibrous (Other)100%Brown

Non-Fibrous

Homogeneous

Tan WB mastic residual E. Corridor

Storage Rm 3

HA: 8

WBM2-2

221705673-0012

None DetectedNon-fibrous (Other)100%Brown

Non-Fibrous

Homogeneous

Tan WB mastic residual E. Corridor

Storage Rm 3

HA: 8

CM1-1

221705673-0013

None DetectedNon-fibrous (Other)100%Brown

Non-Fibrous

Homogeneous

Brown carpet mastic

Rm 107

HA: 9

CBM3-1-Cove Base

221705673-0014

None DetectedNon-fibrous (Other)100%Black

Non-Fibrous

Homogeneous

4" black cove base with mastic Rm 107

HA: 10

CBM3-1-Mastic

221705673-0014A

None DetectedNon-fibrous (Other)100%Tan

Non-Fibrous

Homogeneous

4" black cove base with mastic Rm 107

HA: 10

CBM3-2-Cove Base

221705673-0015

None DetectedNon-fibrous (Other)100%Black

Non-Fibrous

Homogeneous

4" black cove base with mastic Rm 107

HA: 11

CBM3-2-Mastic

221705673-0015A

None DetectedNon-fibrous (Other)100%Tan

Non-Fibrous

Homogeneous

4" black cove base with mastic Rm 107

HA: 11

RB1-1

221705673-0016

None DetectedNon-fibrous (Other)85%Glass15%Black

Fibrous

Homogeneous

Ext Rubber bumper on Loading Dock

HA: 12

DWT1-1-Drywall

221705673-0017

None DetectedGypsum

Non-fibrous (Other)

65%

15%

Cellulose20%Brown/White

Fibrous

Homogeneous

Light OPT over drywall Corridors (102

& 103)

Inseparable paint / coating layer included in analysis

HA: 13

DWT1-2-Drywall

221705673-0018

None DetectedGypsum

Non-fibrous (Other)

65%

15%

Cellulose20%Brown/White

Fibrous

Homogeneous

Light OPT over drywall Corridors (102

& 103)

Inseparable paint / coating layer included in analysis

HA: 13

DWT1-3-Texture

221705673-0019

None DetectedNon-fibrous (Other)100%White

Non-Fibrous

Homogeneous

Light OPT over drywall Corridors (102

& 103)

Inseparable paint / coating layer included in analysis

HA: 13

DWT1-3-Tape

221705673-0019A

None DetectedNon-fibrous (Other)1%Cellulose99%Beige

Fibrous

Homogeneous

Light OPT over drywall Corridors (102

& 103)

HA: 13

Page 2 of 4ASB_PLM_0008_0001 - 1.78 Printed: 8/23/2017 6:45 PM

Tel/Fax: (303) 740-5700 / (303) 741-1400 http://www.EMSL.com / denverlab@emsl.com

221705673EMSL Order:

Customer ID: GSAL42

Customer PO:

Project ID:

Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized

Light Microscopy

Sample Description Appearance % Fibrous % Non-Fibrous

Non-Asbestos Asbestos

% Type

DWT1-3-Joint

Compound

221705673-0019B

None DetectedNon-fibrous (Other)100%White

Non-Fibrous

Homogeneous

Light OPT over drywall Corridors (102

& 103)

HA: 13

DWT1-3-Drywall

221705673-0019C

None DetectedGypsum

Non-fibrous (Other)

65%

15%

Cellulose20%Brown/White

Fibrous

Homogeneous

Light OPT over drywall Corridors (102

& 103)

HA: 13

PL1-1

221705673-0020

None DetectedQuartz

Non-fibrous (Other)

20%

80%

Gray/White

Non-Fibrous

Homogeneous

Painted plaster wall

Corridor 102

HA: 14

PL1-2

221705673-0021

None DetectedQuartz

Non-fibrous (Other)

20%

80%

Gray

Non-Fibrous

Homogeneous

Painted plaster wall

Corridor 102

HA: 14

PL1-3

221705673-0022

None DetectedQuartz

Non-fibrous (Other)

20%

80%

Gray

Non-Fibrous

Homogeneous

Painted plaster wall

Corridor 102

HA: 14

CM2-1

221705673-0023

None DetectedNon-fibrous (Other)100%Yellow

Non-Fibrous

Homogeneous

White & tan carpet mastic S. stairwell

HA: 15

CM2-2

221705673-0024

None DetectedNon-fibrous (Other)100%Yellow

Non-Fibrous

Homogeneous

White & tan carpet mastic S. stairwell

HA: 15

FT2-1-Yellow Mastic

221705673-0025

None DetectedNon-fibrous (Other)100%Yellow

Non-Fibrous

Homogeneous

Floor tile under carpet w/ leveler & 2-3 mastics Top of S.

Stairwell

HA: 16

FT2-1-Leveler

221705673-0025A

None DetectedNon-fibrous (Other)70%Cellulose30%Gray

Non-Fibrous

Homogeneous

Floor tile under carpet w/ leveler & 2-3 mastics Top of S.

Stairwell

HA: 16

FT2-1-Floor Tile

221705673-0025B

None DetectedNon-fibrous (Other)100%Beige

Non-Fibrous

Homogeneous

Floor tile under carpet w/ leveler & 2-3 mastics Top of S.

Stairwell

HA: 16

FT2-1-Black Mastic

221705673-0025C

None DetectedNon-fibrous (Other)100%Black

Non-Fibrous

Homogeneous

Floor tile under carpet w/ leveler & 2-3 mastics Top of S.

Stairwell

HA: 16

FT2-2-Yellow Mastic

221705673-0026

None DetectedNon-fibrous (Other)100%Yellow

Non-Fibrous

Homogeneous

Floor tile under carpet w/ leveler & 2-3 mastics Top of S.

Stairwell

HA: 16

FT2-2-Leveler

221705673-0026A

None DetectedNon-fibrous (Other)90%Cellulose10%Gray

Non-Fibrous

Homogeneous

Floor tile under carpet w/ leveler & 2-3 mastics Top of S.

Stairwell

HA: 16

Page 3 of 4ASB_PLM_0008_0001 - 1.78 Printed: 8/23/2017 6:45 PM

Tel/Fax: (303) 740-5700 / (303) 741-1400 http://www.EMSL.com / denverlab@emsl.com

221705673EMSL Order:

Customer ID: GSAL42

Customer PO:

Project ID:

Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized

Light Microscopy

Sample Description Appearance % Fibrous % Non-Fibrous

Non-Asbestos Asbestos

% Type

FT2-2-Floor Tile

221705673-0026B

None DetectedNon-fibrous (Other)100%Beige

Non-Fibrous

Homogeneous

Floor tile under carpet w/ leveler & 2-3 mastics Top of S.

Stairwell

HA: 16

FT2-2-Black Mastic

221705673-0026C

None DetectedNon-fibrous (Other)100%Black/Yellow

Non-Fibrous

Homogeneous

Floor tile under carpet w/ leveler & 2-3 mastics Top of S.

Stairwell

HA: 16

L1-1

221705673-0027

None DetectedNon-fibrous (Other)80%Cellulose20%Gray

Non-Fibrous

Homogeneous

Leveler associated with CB Top of S.

Stairwell

HA: 17

CBM4-1-Cove Base

221705673-0028

None DetectedNon-fibrous (Other)100%Black

Non-Fibrous

Homogeneous

4" black CB with cream mastic Top of

S. Stairwell

HA: 18

CBM4-1-Mastic

221705673-0028A

None DetectedNon-fibrous (Other)100%Beige

Non-Fibrous

Homogeneous

4" black CB with cream mastic Top of

S. Stairwell

HA: 18

CBM4-2-Cove Base

221705673-0029

None DetectedNon-fibrous (Other)100%Black

Non-Fibrous

Homogeneous

4" black CB with cream mastic Top of

S. Stairwell

HA: 18

CBM4-2-Mastic

221705673-0029A

None DetectedNon-fibrous (Other)100%Beige

Non-Fibrous

Homogeneous

4" black CB with cream mastic Top of

S. Stairwell

HA: 18

TF1-1

221705673-0030

None DetectedNon-fibrous (Other)100%Non-Fibrous

Homogeneous

Tar felt under FT2 Top of S. Stairwell

HA: 19

DTW2-3

221705673-0031

Not SubmittedLight OPT over drywall E. Corridor

Storage Rm 3

HA: 6

WB1-03-Drywall

221705673-0032

None DetectedGypsum

Non-fibrous (Other)

65%

20%

Cellulose

Glass

15%

<1%

Brown/White

Fibrous

Homogeneous

Sample not on COC

Inseparable paint / coating layer included in analysis

HA: 7

Analyst(s)

Amanda Lang (13)

Patricia Wood (34)

Amanda Lang, Asbestos Laboratory Manager or Other Approved Signatory

EMSL maintains liability limited to cost of analysis . This report relates only to the samples reported and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations. Interpretation and use of test results are the responsibility of the client. This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST or any agency of the federal government . Non-friable organically bound materials present a problem matrix and therefore EMSL recommends gravimetric reduction prior to analysis. Samples received in good condition unless otherwise noted. Estimated accuracy, precision and uncertainty data available upon request. Unless requested by the client, building materials manufactured with multiple layers (i.e. linoleum, wallboard, etc.) are reported as a single sample. Reporting limit is 1%

Samples analyzed by EMSL Analytical, Inc. Denver, CO NVLAP Lab Code 200828-0

Page 4 of 4ASB_PLM_0008_0001 - 1.78 Printed: 8/23/2017 6:45 PM

Client Sample Description ConcentrationLab ID Analyzed Lead

Collected

EMSL Analytical, Inc.

200 Route 130 North, Cinnaminson, NJ 08077 Phone/Fax: (856) 303-2500 / (856) 786-5974 http://www.EMSL.com cinnaminsonleadlab@emsl.com

Attn: Robert Smith

GSA

Denver Federal Center Bldg BLDG 41 PO Box 25006 Lakewood, CO 80225

Received: 08/17/17 10:15 AM

081517-BD41-Egress

Fax:

Phone: (720) 275-7459

Project:

8/16/2017Collected:

Test Report: Lead in Paint Chips by Flame AAS (SW 846 3050B/7000B)*

201708253 CustomerID: GSAL42 CustomerPO:

ProjectID:

EMSL Order:

Site: White/tan/green on brick, Rm 107 E.Wall 201708253-0001Pb1 0.13 % wt8/22/20178/15/2017

Site: Ext brown on wood beam, loading dock 201708253-0003Pb3 24 % wt8/22/20178/15/2017

Site: White on plywood corridor by Rm 1124 201708253-0004Pb4 <0.014 % wt8/22/20178/15/2017

Site: White on plaster wall, corridor (Rm 102) 201708253-0006Pb6 0.019 % wt8/22/20178/15/2017

Site: Ext brown/yellow/red on metal bollard 201708253-0007Pb7 11 % wt8/22/20178/15/2017

Site: Gray/black/yellow/red on metal handrails S.Stairwell 201708253-0008Pb8 0.53 % wt8/22/20178/16/2017

Site: Green on wood wall S.Stairwell 201708253-0009Pb9 0.12 % wt8/22/20178/16/2017

Site: White/green on brick wall S.Stairwell 201708253-0010Pb10 0.30 % wt8/22/20178/16/2017

Site: Off-white on drywall E. Corridor Storage Rm No.3 201708253-0011Pb11 <0.0080 % wt8/22/20178/16/2017

Phillip Worby, Lead Laboratory Manager or other approved signatory

Test Report ChmSnglePrm/nQC-7.32.3 Printed: 8/23/2017 11:50:47 AM

*Analysis following Lead in Paint by EMSL SOP/Determination of Environmental Lead by FLAA. Reporting limit is 0.008 % wt based on the minimum sample weight per our SOP. Unless noted, results in this report are not blank corrected. This report relates only to the samples reported above and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities. Samples received in good condition unless otherwise noted. "<" (less than) result signifies that the analyte was not detected at or above the reporting limit. Measurement of uncertainty is available upon request. The QC data associated with the sample results included in this report meet the recovery and precision requirements unless specifically indicated otherwise.

Definitions of modifications are available upon request.

Samples analyzed by EMSL Analytical, Inc. Cinnaminson, NJ NELAP Certifications: NJ 03036, NY 10872, PA 68-00367, AIHA-LAP, LLC ELLAP 100194, A2LA 2845.01

Initial report from 08/23/2017 11:50:47 http://www.EMSL.com mailto:cinnaminsonleadlab@emsl.com

OrderID: 221705673

OrderID: 201708253

File details come from the government source that posted it.