Text version
LIMITED ASBESTOS AND LEAD CONTAINING PAINT
PRE-ALTERATION INSPECTION REPORT
Project ID: 081517-BD41-Egress
Sampling Date: August 15 and 16, 2017
Sampling Location: DFC BD 41 1st Floor Warehouse
Inspector/Cert#: Andi Driessner CDPHE# 20945
Project Scope: Project to install proper egress within the 1st floor warehouse.
BACKGROUND
This limited pre-alteration inspection was completed prior to a renovation project within the federally owned and occupied Building 41 (BD 41) located on the Denver Federal Center with the objective of assessing all building materials set for disturbance specific to the project listed above for asbestos content and lead-containing paint identification.
BD41 is a 498,389 square foot, two-story commercial structure built in 1941 with a brick and wood frame structure; primary use of the building is office space. Prior renovations are vast and full details are unknown. This assessment is limited to three 1st floor warehouse areas: the Central Stair, South Stair and West Egress (detailed in map below), and the northern exterior of BD 41. All other areas and materials not listed in this report are excluded from this survey.
LIMITED ASBESTOS INSPECTION
A limited asbestos inspection was completed in accordance with all applicable local, state, and federal regulations, including but not limited to Colorado Department of Public Health and Environment Air Quality Control Commission Regulation No. 8, Part B Asbestos (5 CCR 1001-10, Part B), U.S. Environmental Protection Agency (EPA) Asbestos Hazard Emergency Response Act (AHERA) sampling protocols (40 CFR
763.86 et seq.), EPA National Emission Standards for Hazardous Air Pollutants (NESHAP)(40 CFR 61 Subpart M), and Occupational Safety and Health Administration (OSHA) asbestos regulations (29 CFR 1910.1001 and 29 CFR 1926.1101) in effect at the time of inspection.
The number of samples taken for each homogeneous area corresponds to the specific material type and quantity to be disturbed. Any further renovation activities that may disturb suspect materials other than those identified for this survey, including larger areas of materials already sampled for this survey, may require further testing and should be completed only after additional sampling of such materials has been conducted. This is not an abatement scope of work nor should it be used as such.
Please contact OFM if further testing is needed.
Samples collected for asbestos analysis were obtained by qualified and appropriately certified/licensed personnel utilizing proper safety measures such as wetting the material prior to sampling, cleaning up the area by wet wiping any resulting residual debris, and wearing proper personal protective equipment, as needed. In order to be certain of sampling the entire thickness of a material, coring tools and knives were utilized to penetrate all layers of a material. All collected samples were then placed in appropriately labeled airtight containers for shipment to the laboratory for analysis under chain of custody protocols.
Nineteen bulk samples, encompassing a total of twenty-eight homogeneous areas, were collected and submitted for bulk sample analysis at EMSL Analytical, Inc. (EMSL).
EMSL is an American Industrial Hygiene Association (AIHA) and National Institute of Standards and Technology (NIST) National Voluntary Laboratory Accreditation Program (NVLAP) laboratory accredited to perform asbestos analytical services. All materials were analyzed by PLM (Polarized Light Microscopy) in accordance with the EPA 600/R- 93/116 method. Multi-layered samples were analyzed by individual layers. A total of forty-seven analyses were conducted accounting for multi-layered samples.
According to OSHA, EPA AHERA, and the EPA National Emission Standards for Hazardous Air Pollutants (NESHAP) criteria, asbestos-containing materials are defined as materials which have at least one (1) sample containing an asbestos content of more than one (1) percent (%) from a homogeneous material area set of samples and all bulk samples from a homogeneous area must be found to contain one (1)% or less of asbestos in order to be classified as non-asbestos-containing. OSHA guidelines apply during the disturbance of materials that contain asbestos detected in any amount;
therefore, materials that were identified as “Trace” (less than one [1] % ACM) by analysis should be accounted for during the planning process for renovation activities.
LEAD-CONTAINING PAINT IDENTIFICATION
Lead-containing paint identification was completed following procedures outlined in the EPA Lead-Based Paint Activities (40 CFR 745 Subpart L), U.S. Housing and Urban Development (HUD) Lead-Based Paint Poisoning Prevention in Certain Residential Structures (24 CFR 35), HUD Guidelines for the Evaluation and Control of Lead-Based Paint Hazards in Housing, OSHA lead regulations (29 CFR 1910.1025 and 29 CFR 1926.62) and the Federal Management Regulation- Real Property, Safety and Environmental Management (41 CFR 102-80.30) in effect at the time of inspection. It should be noted that EPA, HUD, and state regulations don’t apply to non-child occupied commercial or public buildings and have been referenced here as guidance only.
Samples collected for lead paint chip analysis were obtained in a manner consistent with the above referenced regulations by qualified individuals. One representative paint chip sample from each homogenous area, grouped by component type, substrate, visible color, and texture was collected from all coated and painted substrates identified for disturbance during this project. Any materials not identified in this report are excluded from this assessment and would need to be tested or assumed as lead-containing for the project to proceed.
Nine lead paint chip samples were collected and submitted under chain-of-custody protocols for flame atomic absorption spectroscopy (FAAS) analysis via EPA Method SW 846 3050B/7000B to EMSL Analytical, Inc., a laboratory accredited by the EPA National Lead Laboratory Accreditation Program (NLLAP) and AIHA Environmental Lead Laboratory Accreditation Program (ELLAP), and participating in the AIHA Environmental Lead Proficiency Analytical Testing (ELPAT) program. Under the OSHA Lead in Construction Standard, all detectable levels of lead in paints and coatings are regulated, not just the EPA/HUD definition of lead based paint (LBP) of 0.5% by weight.
FINDINGS/CONCLUSIONS
Table 1 below lists all materials sampled, homogeneous areas included, and asbestos results for each sample. Laboratory analysis indicated that asbestos was found in two of the test samples. One type of non-friable asbestos-containing material was identified, the beige 12x12 floor tile in the Central Stair east corridor area #3, partial floor.
Any ACM identified for disturbance or removal in this survey must be removed in accordance with local, state and federal regulations. The removal must be performed by a certified abatement contractor or otherwise appropriately trained. As the disturbance of ACM is less than the trigger levels for Regulation No. 8, being 160 square feet or 260 linear, this activity will fall under the OSHA Asbestos in Construction Standard, 29 CFR
1926.1101. The OSHA defined Competent Person for whomever is completing the work must make the determination of the appropriate class this work will fall into and must comply with all requirements sets forth in 29 CFR 1926.1101. All other materials identified are non-asbestos containing and renovation activities for such may proceed unless other hazards have been identified.
Table 2 below lists lead paint chip sample results for all materials sampled, represented areas included. Laboratory analysis indicated that detectable levels of lead were found in seven of the test samples. All painted surfaces set for disturbance within the West Egress, South Stair and northern exterior area are lead-containing. For the Central Stair, the multilayered paint over brick in Room 107 is lead-containing, although the white painted drywall and plywood walls within the east corridor area #3 did not contain detectable levels for lead. See Table 2 for detailed descriptions and lead concentrations. The OSHA Lead in Construction Standard (29 CFR 1926.62) applies to disturbance of paints or coatings with any detectable concentration of lead. Disturbance includes sanding, burning, welding, scraping, or otherwise impacting. Any project that disturbs assumed or confirmed lead-containing paint must comply with this standard.
Lead-containing paint that is intact and in good condition need not be abated unless required for alteration or demolition and may be removed intact via component removal.
All lead containing debris and lead bearing waste shall be double bagged in 6-millimeter, labeled polyethylene bags, containerized, and transported and properly disposed of off-site at an appropriate facility. The contractor preforming the work shall be responsible for the proper characterization and management of lead bearing waste or debris in accordance with applicable federal, state, and local hazardous waste regulations. Lead bearing waste or debris shall be assumed to be hazardous waste due to the characteristic of toxicity (Lead, EPA Waste Code D008) or have representative waste stream samples submitted to an accredited analytical laboratory for analysis via EPA Method SW-846 Test Method 1311: Toxicity Characteristic Leaching Procedure (TCLP). As applicable, the waste characterization and manifest documentation shall be provided to GSA as part of the deliverable.
Please attach this report to the scope of work for this project. Contact OFM for removal method approval, clearance perimeters, if required, with any questions regarding these results, or if other hazards have been encountered or are suspected in the project area.
Robert V. Smith, CHMM Andi Driessner GSA Regional Industrial Hygienist Industrial Hygienist, Certified BI-Asbestos Robertv.smith@gsa.gov Andrea.driessner@gsa.gov 720-275-7459 720-309-5024 mailto:Robertv.smith@gsa.gov mailto:Andrea.driessner@gsa.gov
Table 1: Asbestos Bulk Sample Results
Sample No.
Homogeneous Material Area A
Area Represented
Sample Location Asb % Friable Cond. B
081517-
BD41-
Egress-
FT1-1
HA# 1
Beige 12x12 floor tile
HA# 2
Yellow mastic
BD 41, central stair, east corridor storage area #3, partial floor
West end storage, by west storage Floor tile:
2% Chrysotile
Mastic:
ND
No Good
081517-
BD41-
Egress-
FT1-2
West end storage, by west storage No Good
081517-
BD41-
Egress-
CT1-1
HA# 3
4x2 faux 2x2 ceiling tile
BD 41, central stair, east corridor storage area #3, ceiling
Southwest entrance ceiling
ND Yes Good
081517-
BD41-
Egress-
CT2-1
HA# 4
2x4 streak & pinhole ceiling tile
BD 41, central stair, east corridor storage area #3 and Rm 107, lodge and bank hallway, partial ceiling
East side ceiling ND Yes Good
081517-
BD41-
Egress-
CT3-1
HA# 5
2x4 streaked ceiling tile
BD 41, central stair, east corridor storage area #3 and Rm 107, lodge and bank hallway, partial ceiling
East side ceiling ND Yes Good
081517-
BD41-
Egress-
CT4-1
HA# 6
2x4 pinholed ceiling tile
BD 41, central stair, east corridor storage area #3 and Rm 107, lodge and bank hallway, partial ceiling
East side ceiling ND Yes Good
Table 1: Asbestos Bulk Sample Results
Sample No.
Homogeneous Material Area A
Area Represented
Sample Location Asb % Friable Cond. B
081517-
BD41-
Egress-
DWT2-1
HA# 7
Light orange peel texture
HA# 8
Drywall
BD 41, central stair, east corridor storage area #3, partial walls
East wall, mid room by cage ND Yes Good
081517-
BD41-
Egress-
DWT2-2
East wall, mid room by cage ND Yes Good
081517-
BD41-
Egress-
DWT2-3
East wall, mid room by cage ND Yes Good
081517-
BD41-
Egress-
WBM1-1 HA# 9
Black residual wallboard mastic
BD 41, central stair, east corridor storage area #3, wall base
East wall, mid room, at base ND No Good
081517-
BD41-
Egress-
WBM1-2
East wall, mid room, at base ND No Good
081517-
BD41-
Egress-
WBM2-1 HA# 10
Tan residual wallboard mastic
BD 41, central stair, east corridor storage area #3, wall base
East wall, mid room, at base ND No Good
081517-
BD41-
Egress-
WBM2-2
East wall, mid room, at base ND No Good
Table 1: Asbestos Bulk Sample Results
Sample No.
Homogeneous Material Area A
Area Represented
Sample Location Asb % Friable Cond. B
081517-
BD41-
Egress-
CM1-1
HA# 11
Brown carpet mastic
BD 41, central stair, east corridor storage area #3, Rm 107 floor under green carpet squares
Rm 107 floor, near south entrance threshold
ND No Good
081517-
BD41-
Egress-
CBM3-1
HA# 12
4” black cove base
HA# 13
Tan mastic
BD 41, central stair, east corridor storage area #3, Rm 107 wall base
North wall, northeast corner at base ND No Good
081517-
BD41-
Egress-
CBM3-2
North wall, northeast corner at base ND No Good
081517-
BD41-
Egress-
RB1-1
HA# 14
Rubber bumper
BD 41, west exterior concrete wall
West exterior concrete partial wall ND No Good
081517-
BD41-
Egress-
DWT1-1
HA# 15
Light orange peel texture
HA# 16
Tape
HA# 17
Joint compound
HA# 18
Drywall
BD 41, west egress, corridor
102 and 103, partial walls, above plywood
Corridor 103, southeast wall 10’ from main entrance
ND Yes Good
081517-
BD41-
Egress-
DWT1-2
Corridor 103, southeast wall 30’ from main entrance
ND Yes Good
081517-
BD41-
Egress-
DWT1-3
Corridor 103, southeast wall 20’ from main entrance
ND Yes Good
Table 1: Asbestos Bulk Sample Results
Sample No.
Homogeneous Material Area A
Area Represented
Sample Location Asb % Friable Cond. B
081517-
BD41-
Egress-
PL1-1
HA# 19
Painted plaster
BD 41, west egress, corridor 102, walls over brick
Corridor 102, east wall by roll up ND Yes Good
081517-
BD41-
Egress-
PL1-2
Corridor 102, east wall by roll up ND Yes Good
081517-
BD41-
Egress-
PL1-3
Corridor 102, east wall by roll up ND Yes Good
081517-
BD41-
Egress-
CM2-1 HA# 20
Tan and white carpet mastic
BD 41, south stairwell, stairs
South stairwell, bottom stairs, 4th step up
ND No Good
081517-
BD41-
Egress-
CM2-2
South stairwell, 2nd stair set, 3rd step up
ND No Good
081517-
BD41-
Egress-
FT2-1
HA# 21
Beige floor tile
HA# 22
Yellow mastic
HA# 23
Black mastic
HA# 24
Black mastic
BD 41, south stairwell, top of top landing, floors under carpet
South stairwell, top landing at stair threshold
ND No Good
081517-
BD41-
Egress-
FT2-2
South stairwell, top landing at stair threshold
ND No Good
081517-
BD41-
Egress- L1-1
HA# 25
Gray leveler
BD 41, south stairwell, top of top landing, under CBM4
South stairwell, top landing under
CMB4-1
ND No Good
Table 1: Asbestos Bulk Sample Results
Sample No.
Homogeneous Material Area A
Area Represented
Sample Location Asb % Friable Cond. B
081517-
BD41-
Egress-
CBM4-1
HA# 26
4” black cove base
HA# 27
Cream mastic
BD 41, south stairwell, top of top landing wall base
South stairwell, southeast wall, wall base at stairs
ND No Good
081517-
BD41-
Egress-
CBM4-2
South stairwell, southeast wall, wall base at stairs
ND No Good
081517-
BD41-
Egress-
TF1-1
HA# 28
Tar felt
BD 41, south stairwell, top of top landing, floor under FT2
South stairwell, top landing, under
FT2-1
ND Yes Good
A = Homogeneous material descriptions include an alpha numeric descriptor delineating the various homogeneous area/materials with a physical description of the material.
B = EPA AHERA Asbestos Assessment Hazard Rankings (condition and friability).
Table 2: Lead Paint Chip Results
Sample No.
Component/ Substrate Paint Color Area
Represented Sample Location
Lead Content (% by wt.)
Pb1 Brick wall White, tan, and green
Central Stair, Room 107 east wall
Room 107, east wall 0.13%
Pb3 Wood frame Brown Exterior wood framing
Exterior loading dock, above roll up 24%
Pb4 Plywood wall White
Central Stair, East corridor storage area
#3 walls
Outside Room 1124, wall BRL*
Pb6 Plaster wall White West Egress, Corridor 102, walls
Corridor 102, wall 0.019%
Pb7 Metal bollard
Brown, yellow, and red
Exterior metal bollards
Exterior metal bollard outside loading dock
11%
Pb8 Metal handrail
Gray, black, yellow, and red
South Stairwell handrails
South stairwell, bottom handrail 0.53%
Pb9 Wood wall Green South stairwell wood walls
South stairwell, wall 0.12%
Pb10 Brick wall White and green
South stairwell brick walls
South stairwell, wall 0.30%
Pb11 Drywall wall Off-white
Central Stair, East corridor storage area #3 drywall walls
East corridor storage area
#3 wall
BRL*
*BRL = Below Reporting Limit ** Samples Pb2 and Pb5 had insufficient sample size and were discluded from analysis.
Map of project and sample locations- Central Stair
= FT1
= CT1
= CT2
= CT3
= CT4
= DWT2
= WBM1
= WBM2
= CM1
= CBM3
= RB1
Map of project and sample locations- Central Stair
= FT1
Map of project and sample locations- West Egress
= DWT1
Map of project and sample locations- West Egress
= PL1
= CM2
= FT2
= L1
= CBM4
= TF1
Map of project and sample locations- South Stair
EMSL Analytical, Inc.
1010 Yuma Street Denver, CO 80204
Tel/Fax: (303) 740-5700 / (303) 741-1400 http://www.EMSL.com / denverlab@emsl.com
221705673EMSL Order:
Customer ID: GSAL42
Customer PO:
Project ID:
Attention: Phone:Robert Smith (720) 275-7459
Fax:GSA
Received Date:Denver Federal Center Bldg 08/16/2017 4:35 PM
Analysis Date:BLDG 41 PO Box 25006 08/23/2017
Collected Date:Lakewood, CO 80225 08/15/2017
Project: 081517-BD41-Egress
Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized
Light Microscopy
Sample Description Appearance % Fibrous % Non-Fibrous
Non-Asbestos Asbestos
% Type
FT1-1-Floor Tile
221705673-0001
2% ChrysotileNon-fibrous (Other)98%Beige
Non-Fibrous
Homogeneous
Beige 12x12 w/ yellow mastic E. corridor
Storage Rm3
HA: 1
FT1-1-Mastic
221705673-0001A
None DetectedNon-fibrous (Other)100%Yellow
Non-Fibrous
Homogeneous
Beige 12x12 w/ yellow mastic E. corridor
Storage Rm3
HA: 1
FT1-2-Floor Tile
221705673-0002
2% ChrysotileNon-fibrous (Other)98%Beige
Non-Fibrous
Homogeneous
Beige 12x12 w/ yellow mastic E. corridor
Storage Rm3
HA: 1
FT1-2-Mastic
221705673-0002A
None DetectedNon-fibrous (Other)100%Yellow
Non-Fibrous
Homogeneous
Beige 12x12 w/ yellow mastic E. corridor
Storage Rm3
HA: 1
CT1-1
221705673-0003
None DetectedNon-fibrous (Other)20%Cellulose
Glass
60%
20%
Gray/White
Fibrous
Homogeneous
4x2 faux 2x2 CT E.
Corridor Storage Rm
HA: 2
CT2-1
221705673-0004
None DetectedNon-fibrous (Other)20%Cellulose
Min. Wool
50%
30%
Gray/White
Fibrous
Homogeneous
2x4 pinhole & streak main CT E. Corridor
Storage Rm 3
HA: 3
CT3-1
221705673-0005
None DetectedNon-fibrous (Other)20%Cellulose
Glass
50%
30%
Gray/White
Fibrous
Homogeneous
2x4 streaked CT E.
Corridor Storage Rm
HA: 4
CT4-1
221705673-0006
None DetectedNon-fibrous (Other)10%Cellulose
Glass
70%
20%
Tan/White
Fibrous
Homogeneous
2x4 pinhole CT E.
Corridor Storage Rm
HA: 5
DWT2-1-Texture
221705673-0007
None DetectedNon-fibrous (Other)100%White
Non-Fibrous
Homogeneous
Light OPT over drywall E. Corridor
Storage RM 3
Inseparable paint / coating layer included in analysis
HA: 6
DWT2-1-Drywall
221705673-0007A
None DetectedGypsum
Non-fibrous (Other)
50%
40%
Cellulose10%Brown/White
Fibrous
Homogeneous
Light OPT over drywall E. Corridor
Storage RM 3
HA: 6
DWT2-2
221705673-0008
None DetectedGypsum
Non-fibrous (Other)
50%
40%
Cellulose10%Brown/White
Fibrous
Homogeneous
Light OPT over drywall E. Corridor
Storage RM 3
Inseparable paint / coating layer included in analysis
HA: 6
WBM1-1
221705673-0009
None DetectedNon-fibrous (Other)100%White/Black
Fibrous
Homogeneous
Black WB mastic residual E. Corridor
Storage Rm 3
HA: 7
Initial report from: 08/23/2017 20:45:50
Page 1 of 4ASB_PLM_0008_0001 - 1.78 Printed: 8/23/2017 6:45 PM
Tel/Fax: (303) 740-5700 / (303) 741-1400 http://www.EMSL.com / denverlab@emsl.com
221705673EMSL Order:
Customer ID: GSAL42
Customer PO:
Project ID:
Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized
Light Microscopy
Sample Description Appearance % Fibrous % Non-Fibrous
Non-Asbestos Asbestos
% Type
WBM1-2
221705673-0010
None DetectedNon-fibrous (Other)100%White/Black
Fibrous
Homogeneous
Black WB mastic residual E. Corridor
Storage Rm 3
HA: 7
WBM2-1
221705673-0011
None DetectedNon-fibrous (Other)100%Brown
Non-Fibrous
Homogeneous
Tan WB mastic residual E. Corridor
Storage Rm 3
HA: 8
WBM2-2
221705673-0012
None DetectedNon-fibrous (Other)100%Brown
Non-Fibrous
Homogeneous
Tan WB mastic residual E. Corridor
Storage Rm 3
HA: 8
CM1-1
221705673-0013
None DetectedNon-fibrous (Other)100%Brown
Non-Fibrous
Homogeneous
Brown carpet mastic
Rm 107
HA: 9
CBM3-1-Cove Base
221705673-0014
None DetectedNon-fibrous (Other)100%Black
Non-Fibrous
Homogeneous
4" black cove base with mastic Rm 107
HA: 10
CBM3-1-Mastic
221705673-0014A
None DetectedNon-fibrous (Other)100%Tan
Non-Fibrous
Homogeneous
4" black cove base with mastic Rm 107
HA: 10
CBM3-2-Cove Base
221705673-0015
None DetectedNon-fibrous (Other)100%Black
Non-Fibrous
Homogeneous
4" black cove base with mastic Rm 107
HA: 11
CBM3-2-Mastic
221705673-0015A
None DetectedNon-fibrous (Other)100%Tan
Non-Fibrous
Homogeneous
4" black cove base with mastic Rm 107
HA: 11
RB1-1
221705673-0016
None DetectedNon-fibrous (Other)85%Glass15%Black
Fibrous
Homogeneous
Ext Rubber bumper on Loading Dock
HA: 12
DWT1-1-Drywall
221705673-0017
None DetectedGypsum
Non-fibrous (Other)
65%
15%
Cellulose20%Brown/White
Fibrous
Homogeneous
Light OPT over drywall Corridors (102
& 103)
Inseparable paint / coating layer included in analysis
HA: 13
DWT1-2-Drywall
221705673-0018
None DetectedGypsum
Non-fibrous (Other)
65%
15%
Cellulose20%Brown/White
Fibrous
Homogeneous
Light OPT over drywall Corridors (102
& 103)
Inseparable paint / coating layer included in analysis
HA: 13
DWT1-3-Texture
221705673-0019
None DetectedNon-fibrous (Other)100%White
Non-Fibrous
Homogeneous
Light OPT over drywall Corridors (102
& 103)
Inseparable paint / coating layer included in analysis
HA: 13
DWT1-3-Tape
221705673-0019A
None DetectedNon-fibrous (Other)1%Cellulose99%Beige
Fibrous
Homogeneous
Light OPT over drywall Corridors (102
& 103)
HA: 13
Page 2 of 4ASB_PLM_0008_0001 - 1.78 Printed: 8/23/2017 6:45 PM
Tel/Fax: (303) 740-5700 / (303) 741-1400 http://www.EMSL.com / denverlab@emsl.com
221705673EMSL Order:
Customer ID: GSAL42
Customer PO:
Project ID:
Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized
Light Microscopy
Sample Description Appearance % Fibrous % Non-Fibrous
Non-Asbestos Asbestos
% Type
DWT1-3-Joint
Compound
221705673-0019B
None DetectedNon-fibrous (Other)100%White
Non-Fibrous
Homogeneous
Light OPT over drywall Corridors (102
& 103)
HA: 13
DWT1-3-Drywall
221705673-0019C
None DetectedGypsum
Non-fibrous (Other)
65%
15%
Cellulose20%Brown/White
Fibrous
Homogeneous
Light OPT over drywall Corridors (102
& 103)
HA: 13
PL1-1
221705673-0020
None DetectedQuartz
Non-fibrous (Other)
20%
80%
Gray/White
Non-Fibrous
Homogeneous
Painted plaster wall
Corridor 102
HA: 14
PL1-2
221705673-0021
None DetectedQuartz
Non-fibrous (Other)
20%
80%
Gray
Non-Fibrous
Homogeneous
Painted plaster wall
Corridor 102
HA: 14
PL1-3
221705673-0022
None DetectedQuartz
Non-fibrous (Other)
20%
80%
Gray
Non-Fibrous
Homogeneous
Painted plaster wall
Corridor 102
HA: 14
CM2-1
221705673-0023
None DetectedNon-fibrous (Other)100%Yellow
Non-Fibrous
Homogeneous
White & tan carpet mastic S. stairwell
HA: 15
CM2-2
221705673-0024
None DetectedNon-fibrous (Other)100%Yellow
Non-Fibrous
Homogeneous
White & tan carpet mastic S. stairwell
HA: 15
FT2-1-Yellow Mastic
221705673-0025
None DetectedNon-fibrous (Other)100%Yellow
Non-Fibrous
Homogeneous
Floor tile under carpet w/ leveler & 2-3 mastics Top of S.
Stairwell
HA: 16
FT2-1-Leveler
221705673-0025A
None DetectedNon-fibrous (Other)70%Cellulose30%Gray
Non-Fibrous
Homogeneous
Floor tile under carpet w/ leveler & 2-3 mastics Top of S.
Stairwell
HA: 16
FT2-1-Floor Tile
221705673-0025B
None DetectedNon-fibrous (Other)100%Beige
Non-Fibrous
Homogeneous
Floor tile under carpet w/ leveler & 2-3 mastics Top of S.
Stairwell
HA: 16
FT2-1-Black Mastic
221705673-0025C
None DetectedNon-fibrous (Other)100%Black
Non-Fibrous
Homogeneous
Floor tile under carpet w/ leveler & 2-3 mastics Top of S.
Stairwell
HA: 16
FT2-2-Yellow Mastic
221705673-0026
None DetectedNon-fibrous (Other)100%Yellow
Non-Fibrous
Homogeneous
Floor tile under carpet w/ leveler & 2-3 mastics Top of S.
Stairwell
HA: 16
FT2-2-Leveler
221705673-0026A
None DetectedNon-fibrous (Other)90%Cellulose10%Gray
Non-Fibrous
Homogeneous
Floor tile under carpet w/ leveler & 2-3 mastics Top of S.
Stairwell
HA: 16
Page 3 of 4ASB_PLM_0008_0001 - 1.78 Printed: 8/23/2017 6:45 PM
Tel/Fax: (303) 740-5700 / (303) 741-1400 http://www.EMSL.com / denverlab@emsl.com
221705673EMSL Order:
Customer ID: GSAL42
Customer PO:
Project ID:
Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized
Light Microscopy
Sample Description Appearance % Fibrous % Non-Fibrous
Non-Asbestos Asbestos
% Type
FT2-2-Floor Tile
221705673-0026B
None DetectedNon-fibrous (Other)100%Beige
Non-Fibrous
Homogeneous
Floor tile under carpet w/ leveler & 2-3 mastics Top of S.
Stairwell
HA: 16
FT2-2-Black Mastic
221705673-0026C
None DetectedNon-fibrous (Other)100%Black/Yellow
Non-Fibrous
Homogeneous
Floor tile under carpet w/ leveler & 2-3 mastics Top of S.
Stairwell
HA: 16
L1-1
221705673-0027
None DetectedNon-fibrous (Other)80%Cellulose20%Gray
Non-Fibrous
Homogeneous
Leveler associated with CB Top of S.
Stairwell
HA: 17
CBM4-1-Cove Base
221705673-0028
None DetectedNon-fibrous (Other)100%Black
Non-Fibrous
Homogeneous
4" black CB with cream mastic Top of
S. Stairwell
HA: 18
CBM4-1-Mastic
221705673-0028A
None DetectedNon-fibrous (Other)100%Beige
Non-Fibrous
Homogeneous
4" black CB with cream mastic Top of
S. Stairwell
HA: 18
CBM4-2-Cove Base
221705673-0029
None DetectedNon-fibrous (Other)100%Black
Non-Fibrous
Homogeneous
4" black CB with cream mastic Top of
S. Stairwell
HA: 18
CBM4-2-Mastic
221705673-0029A
None DetectedNon-fibrous (Other)100%Beige
Non-Fibrous
Homogeneous
4" black CB with cream mastic Top of
S. Stairwell
HA: 18
TF1-1
221705673-0030
None DetectedNon-fibrous (Other)100%Non-Fibrous
Homogeneous
Tar felt under FT2 Top of S. Stairwell
HA: 19
DTW2-3
221705673-0031
Not SubmittedLight OPT over drywall E. Corridor
Storage Rm 3
HA: 6
WB1-03-Drywall
221705673-0032
None DetectedGypsum
Non-fibrous (Other)
65%
20%
Cellulose
Glass
15%
<1%
Brown/White
Fibrous
Homogeneous
Sample not on COC
Inseparable paint / coating layer included in analysis
HA: 7
Analyst(s)
Amanda Lang (13)
Patricia Wood (34)
Amanda Lang, Asbestos Laboratory Manager or Other Approved Signatory
EMSL maintains liability limited to cost of analysis . This report relates only to the samples reported and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations. Interpretation and use of test results are the responsibility of the client. This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST or any agency of the federal government . Non-friable organically bound materials present a problem matrix and therefore EMSL recommends gravimetric reduction prior to analysis. Samples received in good condition unless otherwise noted. Estimated accuracy, precision and uncertainty data available upon request. Unless requested by the client, building materials manufactured with multiple layers (i.e. linoleum, wallboard, etc.) are reported as a single sample. Reporting limit is 1%
Samples analyzed by EMSL Analytical, Inc. Denver, CO NVLAP Lab Code 200828-0
Page 4 of 4ASB_PLM_0008_0001 - 1.78 Printed: 8/23/2017 6:45 PM
Client Sample Description ConcentrationLab ID Analyzed Lead
Collected
EMSL Analytical, Inc.
200 Route 130 North, Cinnaminson, NJ 08077 Phone/Fax: (856) 303-2500 / (856) 786-5974 http://www.EMSL.com cinnaminsonleadlab@emsl.com
Attn: Robert Smith
GSA
Denver Federal Center Bldg BLDG 41 PO Box 25006 Lakewood, CO 80225
Received: 08/17/17 10:15 AM
081517-BD41-Egress
Fax:
Phone: (720) 275-7459
Project:
8/16/2017Collected:
Test Report: Lead in Paint Chips by Flame AAS (SW 846 3050B/7000B)*
201708253 CustomerID: GSAL42 CustomerPO:
ProjectID:
EMSL Order:
Site: White/tan/green on brick, Rm 107 E.Wall 201708253-0001Pb1 0.13 % wt8/22/20178/15/2017
Site: Ext brown on wood beam, loading dock 201708253-0003Pb3 24 % wt8/22/20178/15/2017
Site: White on plywood corridor by Rm 1124 201708253-0004Pb4 <0.014 % wt8/22/20178/15/2017
Site: White on plaster wall, corridor (Rm 102) 201708253-0006Pb6 0.019 % wt8/22/20178/15/2017
Site: Ext brown/yellow/red on metal bollard 201708253-0007Pb7 11 % wt8/22/20178/15/2017
Site: Gray/black/yellow/red on metal handrails S.Stairwell 201708253-0008Pb8 0.53 % wt8/22/20178/16/2017
Site: Green on wood wall S.Stairwell 201708253-0009Pb9 0.12 % wt8/22/20178/16/2017
Site: White/green on brick wall S.Stairwell 201708253-0010Pb10 0.30 % wt8/22/20178/16/2017
Site: Off-white on drywall E. Corridor Storage Rm No.3 201708253-0011Pb11 <0.0080 % wt8/22/20178/16/2017
Phillip Worby, Lead Laboratory Manager or other approved signatory
Test Report ChmSnglePrm/nQC-7.32.3 Printed: 8/23/2017 11:50:47 AM
*Analysis following Lead in Paint by EMSL SOP/Determination of Environmental Lead by FLAA. Reporting limit is 0.008 % wt based on the minimum sample weight per our SOP. Unless noted, results in this report are not blank corrected. This report relates only to the samples reported above and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities. Samples received in good condition unless otherwise noted. "<" (less than) result signifies that the analyte was not detected at or above the reporting limit. Measurement of uncertainty is available upon request. The QC data associated with the sample results included in this report meet the recovery and precision requirements unless specifically indicated otherwise.
Definitions of modifications are available upon request.
Samples analyzed by EMSL Analytical, Inc. Cinnaminson, NJ NELAP Certifications: NJ 03036, NY 10872, PA 68-00367, AIHA-LAP, LLC ELLAP 100194, A2LA 2845.01
Initial report from 08/23/2017 11:50:47 http://www.EMSL.com mailto:cinnaminsonleadlab@emsl.com
OrderID: 221705673
OrderID: 201708253
File details come from the government source that posted it.