3-_Location_3_Reference_Only.xlsm

XLSM spreadsheet 151 KB Posted

Attached to
Fire Protection & Safety Surveys Federal contract opportunity
Solicitation number
47PF0019Q0048
Issued by
General Services Administration Public Buildings Service Region 5

About this file

Location 3 Reference Attachment

View the file

Other files for this federal contract opportunity

Other files attached to Fire Protection & Safety Surveys, newest first.
File Type Posted
Combined_Synopsis-Solicitation.pdf PDF
1-_Location_1_Reference_Only.xlsx XLSX spreadsheet
47PF0019Q0048__SF18.pdf PDF
4-_Location_4_Reference_Only.xlsm XLSM spreadsheet
5-_Location_5_Reference_Only.xlsm XLSM spreadsheet
6-_Location_6_Reference_Only.xlsm XLSM spreadsheet
8-_FLS_Contractor_Quote_Sheet.xlsx XLSX spreadsheet
2-_Location_2_Reference_Only.xlsm XLSM spreadsheet
7-_Location_7_Reference_Only.xlsm XLSM spreadsheet
RFQ_Fire_and_Safety_Surveys.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

RAC Summary

National Consolidated Risk Management Survey

FIRE PROTECTION

RAC Summary

Survey AreaRAC Score
Means of Egress
Fire Detection and Alarm
Fire Suppression
Smoke Control
Other

Fire Protection Survey Overall RAC Score:

Building Information

National Consolidated Risk Management Survey

Building Information

Questions Response Findings/Observations

Building Profile
Region5
GSA Building NumberIL0220ZZ
GSA Building NameFederal Building
Building Street Address650 W Missouri Ave.
Building CityEast St. Louis
Building StateIL 62201-2955
Date(s) of Onsite Survey
Surveyor
Type of Occupancies
Building Point(s) of Contact for SurveysJames Hill (618) 482-9377
Date of Building Construction1966
Date of Last Major Building Renovation2011 = Roof replacement and Sprinkler Project
Has any work been done since the last survey (e.g., any tenant fit-outs, changes in occupancy, etc.)? If yes, please describe in the findings section.N/A
Property TypeFB
What is the tenant breakdown?Multiple
Primary TenantsSSA, U.S. Courts
Is there a law enforcement tenant in this facility?Unknown
Name of O&M or Facilities Management Services Contractor
Name of Custodial Services Contractor
Identify any Unique Space Type(s). If "other" is chosen, please describe the "other" unique space in the comments section.
Building Size (GSF)33,802
Building Size (RSF)31,990
Total Number of Floors Above Grade2
Total Number of Floors Below Grade
Is the building a highrise according to Rexus?No
Is the building a highrise according to FPE?No
What is the building construction classification (IBC Code)?
What is the pitch of roof?
Are there photovoltaic (PV) cells on the roof?Unknown
Type of Roof Anchoring System
Are there antennas?Unknown
How many elevators are there?
Identify Fuel Fired Equipment
What are the fuel types?
How many confined spaces are there?
What type of confined spaces are there?
How many permit-required confined spaces are there?
What is the potable water source?
Is there asbestos containing material(s)?
Is there lead paint or other lead material(s)?
Is there PCB containing material(s)?
What energy sources are used onsite? (select all that apply)
Above-Ground Storage Tanks (ASTs)
Are there any ASTs?
If yes, how many are there?
What is their total value?
Tank Size (gallons)
Type
Tank Location
Fuel Type
Installation Date
Underground Storage Tanks (USTs)
Are there any USTs?No
If yes, how many are there?N/A
What is their total value?N/A
Tank Size (gallons)N/A
TypeN/A
Tank LocationN/A
Fuel TypeN/A
Installation DateN/A
Occupant Emergency Plan (OEP)
Is there an OEP?
Date of plan
Are persons in plan current?
Is there OEP training for designated persons?
Are there procedures for evacuation of disabled persons?
Are there procedures for after-hours emergencies?
Is there a fire department pre-fire plan?

Means of Egress

National Consolidated Risk Management Survey

Means of Egress

#QuestionsResponseFindings/ObservationsRegulatory CitationRisk Assessment Code (RAC)Recommended Corrective Actions
ProbabilitySeverityRACIs there a recommended corrective action associated with this item?LocationRecommended Action
Means of Egress Components
1Are doors in compliance? If no, identify and describe the circumstances in the findings section.
2Are stairs in compliance? If no, identify and describe the circumstances in the findings section.
3Are handrail/guards in compliance? If no, identify and describe the circumstances in the findings section.
4Are ramps in compliance? If no, identify and describe the circumstances in the findings section.
5Are horizontal exits in compliance? If no, identify and describe the circumstances in the findings section.
6Are exit passageways in compliance? If no, identify and describe the circumstances in the findings section.
7Other means of egress elements noted? If no, identify and describe the circumstances in the findings section.
Capacity of Means of Egress
8Is the means of egress capacity based on occupant load for floor and area adequate?
9Is egrees capacity adequate at convergence points?
Means of Egress Minimum Width
10Is the means of egress minimum width maintained (i.e. 44" or 36" where permitted)?
Number of Exits
11Are the required number of exits provided for floor or area?
12Are there interlocking or scissor stairs present (if yes, counts as 1 exit)?---
Arrangement of Means of Egress
13Are exits readily accessible? If no, identify and describe the circumstances in the findings section.
14Are common path of travel and dead end arrangements in compliance? If no, identify and describe the circumstances in the findings section.
15Are exits arranged to be remote per code? If no, identify and describe the circumstances in the findings section.
16Are travel distances in compliance? If no, identify and describe the circumstances in the findings section.
Discharge of Means of Egress
17Is the exit discharge in compliance? If no, identify and describe the circumstances in the findings section.
Illumination of Means of Egress
18If emergency lighting is provided, is there adequate coverage? If no, identify and describe the circumstances in the findings section.
19Is there a current emergency lighting testing and maintenance report? If yes, please identify the date and any findings in the findings section.
Marking Means of Egress
20Are adequate markings of means of egress provided? If no, identify and describe the circumstances in the findings section.
21Is the illumination of the markings of means of egress in compliance? If no, identify and describe the circumstances in the findings section.
Elevators
22How many elevators are in the building?---
23What is the installation date(s) of the elevator(s)?---
24Do elevators have firemans recall phase I or II?---
25Are any of the elevators used as a required means of egress?---
Other Findings
26

Overall Means of Egress RAC

Once the surveyor has reviewed the Means of Egress findings and Overall RAC provided above, if the RAC does not represent the risk associated with the findings as a whole, please provide an adjusted RAC and explanation below.

User Adjusted Means of Egress RAC

Explanation of User Adjusted RAC

Fire Detection and Alarm

National Consolidated Risk Management Survey

Fire Detection and Alarm

#QuestionsResponseFindings/ObservationsRegulatory CitationRisk Assessment Code (RAC)Recommended Corrective Actions
ProbabilitySeverityRACIs there a recommended corrective action associated with this item?LocationRecommended Action
Fire Detection and Alarm
27Is there a fire alarm system installed? If no, please explain in the findings section.---
28If there is a fire alarm system installed, is the system operational and functioning correctly?
29What is the fire alarm system type?---
30Is there a current (NFPA 72) test and maintenance report? If yes, please identify the date and any findings in the findings section.
31Is there off-site notification? If yes, please describe notification in the findings section.---
Fire Alarm Control Panel
32What is the age of the control panel?---
33Where is the fire alarm control panel located?---
34Identify the fire alarm manufacturer (type/model).---
35Is there a fire command station or emergency control center? If yes, please identify in the findings section.---
Initiating Devices
36Are there manual pull station issues? If yes, please describe in the findings section.
37Are there smoke detectors issues? If yes, please describe in the findings section.
38Are there duct detectors issues? If yes, please describe in the findings section.
39Are there heat detectors issues? If yes, please describe in the findings section.
40Are there water flow switches issues? If yes, please describe in the findings section.
41Are there valve supervision issues? If yes, please describe in the findings section.
42Are there any other initiating devices with issues? If yes, please describe in the findings section.
Notification Devices
43Are there any visual device problems? If yes, please describe problems and date of test and maintenance report in the findings section.
44Are there any audibility problems? If yes, please describe in the findings section.
Other Findings
45

Overall Fire Detection and Alarm RAC

Once the surveyor has reviewed the Fire Detection and Alarm findings and Overall RAC provided above, if the RAC does not represent the risk associated with the findings as a whole, please provide an adjusted RAC and explanation below.

User Adjusted Fire Detection and Alarm RAC

Explanation of User Adjusted RAC

Fire Suppression

National Consolidated Risk Management Survey

Fire Suppression

#QuestionsResponseFindings/ObservationsRegulatory CitationRisk Assessment Code (RAC)Recommended Corrective Actions
ProbabilitySeverityRACIs there a recommended corrective action associated with this item?LocationRecommended Action
Automatic Sprinklers
46Is there a fire sprinkler system installed? If no, please explain in the findings section. If yes, please complete the questions below.
47What is type of fire sprinkler system?---
48What is the age of the oldest sprinkler?
49What percentage of the facility has a fire protection system?
50Is there a current (NFPA 25) maintenance report? If yes, please identify the date and any findings in the findings section.
51Are there any identified fire sprinkler issues? If yes, please explain in the findings section.
Standpipes
52What are the types of standpipes?---
53Is there current (NFPA 25) maintenance record? If yes, please identify the date and any findings in the findings section.
54Are there any standpipe issues? If yes, please explain in the findings section.
Fire Pumps
55Are there any fire pump(s)? If yes, please complete the questions below.---
56What is the location of the fire pump(s)?---
57What is the size of the fire pump, ___gpm at ___psi?---
58Is there a current (NFPA 25) maintenance record? If yes, please identify the date and any findings in the findings section.
59Are there any fire pump issues? If yes, please explain in the findings section.
60What is the power source? If diesel, identify any fuel storage issues in the findings section.
Fire Extinguishers
61Are there fire extinguishers? If yes, please complete the questions below.---
62Have the fire extinguishers been maintained per NFPA 10? If no, identify issues in the findings section.
63Are the fire extinguishers properly located and sized in compliance with NFPA 10? If no, please explain in the findings section.
Other Suppression Systems
64Are there other suppression systems? If yes, please describe location and type in the findings section.
65Are there current maintenance records? What is the date of the last test?
66Are there identified issues? If yes, please explain in the findings section.
Other Findings
67

Overall Fire Suppression RAC

Once the surveyor has reviewed the Fire Suppression findings and Overall RAC provided above, if the RAC does not represent the risk associated with the findings as a whole, please provide an adjusted RAC and explanation below.

User Adjusted Fire Suppression RAC

Explanation of User Adjusted RAC

Smoke Control

National Consolidated Risk Management Survey

Smoke Control

#QuestionsResponseFindings/ObservationsRegulatory CitationRisk Assessment Code (RAC)Recommended Corrective Actions
ProbabilitySeverityRACIs there a recommended corrective action associated with this item?LocationRecommended Action
Smoke Control
68Is there a smoke control system present?
69What is the application of the smoke control system? Please provide the location in the findings section.
70Is there a current maintenance record? If yes, please identify the date and any findings in the findings section.
71Are there any smoke control issues? If yes, please explain in the findings section.
Other Findings
72

Overall Smoke Control RAC

Once the surveyor has reviewed the Smoke Control findings and Overall RAC provided above, if the RAC does not represent the risk associated with the findings as a whole, please provide an adjusted RAC and explanation below.

User Adjusted Smoke Control RAC

Explanation of User Adjusted RAC

Other

National Consolidated Risk Management Survey

Other

#QuestionsResponseFindings/ObservationsRegulatory CitationRisk Assessment Code (RAC)Recommended Corrective Actions
ProbabilitySeverityRACIs there a recommended corrective action associated with this item?LocationRecommended Action
Fire and Smoke Barriers
73Are vertical applications (i.e. stairwell, HVAC shafts) properly maintained? If no, please describe in the comments section.
74Are horizontal applications (i.e. floors, corridors, special hazard areas) properly maintained? If no, please describe in the comments section.
75Are special use areas (i.e. laboratories, firing range) properly maintained? If no, please describe in the comments section.
76Are penetrations properly maintained? If no, please describe in the comments section.
77Are opening protective's properly maintained? If no, please describe in the comments section.
78Are all other fire barriers properly maintained? If no, please describe in the comments section.
79Are there fire dampers, smoke dampers, or combination dampers? If yes, provide where they are located in the findings section.
80Is there a current maintenance record (NFPA 80)? If yes, please identify the date and any findings in the findings section.
On-Site Power Generation
81Is there on-site power generation? If yes, please select the appropriate type from the drop down menu.---
82Identify on-site power generation location.---
83Are firefighter provisions in place?---
On-Site Fuel Storage
84Is there on-site fuel storage? If yes, please select the appropriate type from the drop down menu and provide the location and size in the findings section.
85What is the intended use of on-site fuel?---
86Are there any maintenance records and associated identified issues or concerns? If yes, please explain in the findings section.
Emergency Power
87Are there emergency generator(s)?---
88Is there a current maintenance record (NFPA 110)? If yes, please identify the date and any findings in the findings section.
89Are there any identified issues? If yes, please explain in the findings section.
Kitchen Use
90Is there commercial cooking equipment present? If yes, identify equipment and related fire protection features (i.e. ventilation hoods) in the findings section.
91Are there any current (NFPA 96) maintenance records? If yes, please identify the date and any findings in the findings section.
92Are there any identified kitchen issues? If yes, please explain in the findings section.
Interior Finishes
93Are interior finishes compliant with the occupancy use? If no, please describe in the findings section.
Fire Planning and Prevention
94Is the fire rating being maintained? If no, then note areas not maintained in the findings section.
95Is there a fire command room?---
96Are there any other overall fire prevention issues? If yes, please describe in the findings section.
Other Findings
97

Overall Other RAC

Once the surveyor has reviewed the Other findings and Overall RAC provided above, if the RAC does not represent the risk associated with the findings as a whole, please provide an adjusted RAC and explanation below.

User Adjusted Other RAC

Explanation of User Adjusted RAC

Work Item Summary

National Consolidated Risk Management Survey

Work Item Summary and Tracking Sheet

# Findings/Observations Recommended Action Location Action Taken Completion Date

Means of EgressMeans of Egress
1
2
3
4
5
6
7
Capacity of Means of Egress
8
9
Means of Egress Minimum Width
10
Number of Exits
11
12
Arrangement of Means of Egress
13
14
15
16
Discharge of Means of Egress
17
Illumination of Means of Egress
18
19
Marking Means of Egress
20
21
Elevators
22
23
24
25
Other Findings - Means of Egress
26
Fire Detection and AlarmFire Detection and Alarm
27
28
29
30
31
Fire Alarm Control Panel
32
33
34
35
Initiating Devices
36
37
38
39
40
41
42
Notification Devices
43
44
Other Findings - Fire Detection and Alarm
45
Fire SuppressionAutomatic Sprinklers
46
47
48
49
50
51
Standpipes
52
53
54
Fire Pumps
55
56
57
58
59
60
Fire Extinguishers
61
62
63
Other Suppression Systems
64
65
66
Other Findings - Fire Suppression
67
Smoke ControlSmoke Control
68
69
70
71
Other Findings - Smoke Control
72
OtherFire and Smoke Barriers
73
74
75
76
77
78
79
80
On-Site Power Generation
81
82
83
On-Site Fuel Storage
84
85
86
Emergency Power
87
88
89
Kitchen Use
90
91
92
Interior Finishes
93
Fire Planning and Prevention
94
95
96
Other Findings - Other
97

RAC Guidance

National Consolidated Risk Management Survey Severity and Probability Assessment Guidance

SEVERITY ASSESSMENT GUIDANCE
SCOPE and APPLICABILITY
Environmental RiskFire Protection RiskSafety & Health Risk
Contamination of air, water soil, and biota or non-compliance with environmental regulationsEffects to occupants or facility as a result of a condition or potential event.Adverse health effects or injury to facility occupants, contractors or visitors in response to a condition or event
SEVERITY LEVEL DEFINITIONS
CATASTROPHICIrreversible long-term impacts.(1) Death, permanent disability or irreversible health effect to occupants or (2) a loss of an entire facility.Permanent disability, irreversible health effect or death.

SEVERE Reversible long-term damage (5+ years to remediate). (1) Severe injury, potential long-term health effect or (2) major loss or impact to a facility. Potential long-term health effect or severe injury.

SIGNIFICANT Reversible medium-term damage (1-5 years to remediate). (1) Minor injury or reversible health effect or (2) damage to a portion of a facility requiring an extended period of time to repair. Reversible health effect or minor injury.

MODERATE Reversible short-term impact (<1 year to remediate). (1) First aid, no lost time or (2) damage to a facility requiring a minimal amount of time to repair. First aid or no lost time.

MINOR De minimis regulatory violation. De minimis code violation. De minimis code violation.

NO IMPACTNo risk of impact.No risk of impact to the occupants or facility.No risk of impact.
PROBABILITY ASSESSMENT GUIDANCE
PROBABILITY LEVEL DEFINITIONS
LikelyImminent

or

1 in 10
ProbableProbable

or

1 in 100
PossiblePossible

or

1 in 1000
RemoteRemote

or

1 in 10,000
UnlikelyUnlikely

or

1 in 100,000
Not PossibleNon-existent

RAC

ProbabilityRAC_probabilityRAC severity
SeverityImminentProbablePossibleRemoteUnlikelyNot Possible
Catastrophic112336AI
Severe123346BII
SIGNIFICANT233446CIII
MODERATE334456DIV
MINOR344556EV
NO IMPACT666666

Lists

Yes/Noyes/No/NANFPA:Common TerminologyNFPAFireAlarmSystemsIBCStandpipe TypesRegionsOldest SprinklersOccupancy TypesOffsite NotificationSprinkler SystemSmoke Control SystemGenerator TypeOn Site Fuel StorageBuilding MaterialsRisersNAYNActionProbabilitySeverityFireProtectionPropertyTypeTenant BreakdownUnique SpacesConfinedSpacesPotable Water SourceAnchoring SystemEnergySources
YesEmergency Communication Systems1YesImminentCatastrophic0-24%MultipleCafeteriaManholesMunicipalDavitFossil Fuels
YesNoType I (443)Fire Resistive, Non-CombustibleType I (443)/Fire Resistive, Non-CombustibleProtected Premise SystemsIAClass I2StandardBusinessMegacenterWetStair PressurizationPhotovoltaicLP ContainersCombustible4N/ANoProbableSevere25-49%Border StationSingleCCCSewage Ejection PitWell-waterEngineeredNatural Gas
NoN/AType I (332)Fire Resistive, Non-CombustibleType I (332)/Fire Resistive, Non-CombustibleIBClass II3Quick ResponsePublic AssemblyLocal Fire DepartmentDryAtriumWind TurbinesDieselLimited Combustible6PossibleSignificant50-74%CHExplosive StorageTanksTie-backWind
UnknownType II (222)Fire Resistive, Non-CombustibleType II (222)/Fire Resistive, Non-CombustibleIIAClass III4StorageUL Central StationDelugeOtherGeothermalGasolineNon-Combustible8RemoteModerate75-99%FBFiring RangeVaultedSolar
Type II (111)Protected Non-combustibleType II (111)/Protected Non-combustibleIIBCombination5Light IndustrialOtherPre-ActionN/AMicroturbinesOtherOtherUnlikelyMinor100%GarageHolding CellsOtherGeothermal
Type II (000)Unprotected Non-combustibleType II (000)/Unprotected Non-combustibleIIIAWet6Child CareOther (Please Identify in Comments)N/ANot PossibleNo ImpactWarehouseLaboratoryN/AHydropower
Type III (211)Protected OrdinaryType III (211)/Protected OrdinaryIIIBDry7Mixed OccupancyNoneWareyardSallyportOther
Type III (200)Unprotected OrdinaryType III (200)/Unprotected OrdinaryIVN/A8OtherSecure Space
Type IV (2HH)Heavy TimberType IV (2HH)/Heavy TimberVAUnknown9WWTP
Type V (111)Protected CombustibleType V (111)/Protected CombustibleVB10Other
Type V (000)Unprotected CombustibleType V (000)/Unprotected Combustible11