47PB0020B0001Tab_2_West_Berkshire_Booth_Replacement_SOW_2019_07_02.pdf

PDF 605 KB Posted

Attached to
East Richford LPOE Intrusion Detection System and Refresh Federal contract opportunity
Solicitation number
47PB0020B0001
Issued by
General Services Administration Public Buildings Service Region 1

About this file

This pre-solicitation notice seeks construction services for renovations and upgrades at three land port of entry facilities located in Vermont. Renovations include creating office spaces, restrooms, security upgrades, and replacing inspection booths. Temporary facilities are also required during construction. The estimated value is between $1 and $2 million. The solicitation will be available on October 17th and bids are due by November 18th. The contract is a 100% small business set-aside under NAICS Code 236220. A pre-bid site visit will be held on October 29th. The General Services Administration is the contracting agency.

West Berkshire Booth Replacement Scope of Work

View the file

Other files for this federal contract opportunity

Other files attached to East Richford LPOE Intrusion Detection System and Refresh, newest first.
File Type Posted
285-053-002_Port_Refresh_East_Richford_LPOE_dwgs.pdf PDF
47PB0020B0001_Tab_2_Richford_Booth_Replace_SOW_2019_07_02.pdf PDF
AD-101_Rev_1.pdf PDF
Port_Refresh_East_Richford_LPOE_Specifications.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

WEST BERKSHIRE – BOOTH REPLACEMENT PROJECT

FFR 17-1345

’-9

6’

-1

11’-10”12’-0”3’-0” 11’-8” 3’-8”

MIRROR

FIELD MEASUREMENTS

CURB HEIGHT - 7”

BOOTH SIZE – 4’-7” X 6’-4”

ROADWAY SLOPE / See Elevations page. (approx. 20’)

Heated

HVAC/ELECTRICAL/DATA CHASE

• HVAC UNIT located on roof of booth under canopy.

• Provide electrical outlet on roof for equipment usage by repair personnel.

• Continue chase horizontally under windows and counter.

• Add vertical chase to ceiling for data and electrical to CCTV in location shown. No exposed conduit.

LIGHTING

• Interior: 2 2X2 LED lights over counter.

• Exterior: LED light over doors and one mounted on side without door. See elevation drawings for locations.

HEATING

• Quick recovery unit.

• Heated Floor Mat sized to the booth floor.

WINDOWS and DOORS

• Level 3, BR Rated glass with tinting.

• Add shades for each window.

COUNTER

• Solid surface material

• Blocking under counter for CPU hanger.

• Minimum of three (3) 2” grommet holes for wire management.

BOOTH ENVELOPE

• Level 3, BR rated material. All exterior piping and connections to be sealed.

CAMERAS AND MICROPHONES

• Install two (2) cameras with microphone capability, or install separate microphone under camera, on booth as shown. They are to be mounted at approximately 60” to 66” – actual height to be determined at time of installation to insure viewing inside vehicle is correct.

STATEMENT OF WORK

WEST BERKSHIRE – BOOTH REPLACEMENT PROJECT

FFR 17-1345

EQUIPMENT RE-INSTALLATION AND NEW

• Install panel to house the RPM annunciators (2), the switch to the siren, duress button and switch for lane lights. Wire all items into this panel and label accordingly.

• Add a radio console in booth.

• Replace existing siren with a new siren.

• Add two (2) Cameras and Microphones, can be combined unit or separate.- see note under

“Cameras and Microphones.”

• Add CCTV Monitor (23”) and bracket suspended from ceiling.

SIGNAGE AND LANE PAVEMENT/RE-ALIGNMENT

• Score pavement starting from the start of LANE 1 under canopy, realign curbing and pave area sloping the roadway to meet at the top of the curb at booth and tapering away toward the building. Pavement slope not to exceed 3% and transition to be gradual for vehicle to easily transition back to level roadway. Refer to Elevation drawing.

• Install three 2” posts in pavement at LANE 1.(signage provided by CBP).

11’-10”

6’-1”

8’-0”

HVAC/DATA

CHASE

CEILING HATCH

LIGHTING

LIGHTING

COUNTER

RIGHT SIDE

LEFT SIDE

BUILDING

OUTBOUND LANE

CAMERA AND MIC

CAMERA AND MIC

PLAN VIEW

11’-10”

6’-1”

8’-0”

HVAC/ELEC/

DATA CHASE

HVAC/ELECTRICAL/DATA CHASE

• UTILIZE CHASE FOR WIRING

RUNS AND OUTLETS, PANELS

AND DATA BOXES.

COUNTER

1N DATA & 1 DUPLEX

AT CEILING FOR CCTV.

1 DUPLEX BELOW

COUNTER.

3N/1R DATA & 1 QUAD

BELOW COUNTER.

3N/1T DATA & 1 QUAD

BELOW COUNTER.

1 DUPLEX BELOW

COUNTER.

RIGHT SIDE

LEFT SIDE

CPU HANGER

LOCATION.

PANEL BOX TO HOUSE:

• SIREN BUTTON

• RPM ANNUNCIATORS

• DURESS BUTTON

• SWITCH FOR LANE LIGHTS

DATA – 3N/1R AND 3N/1T

DATA – 1N

DUPLEX

QUAD

KEY AND NOTES

PLAN VIEW - ELECTRICAL/DATA

BUILDING

OUTBOUND LANE

ANGLED WALL

SOLID SURFACE

COUNTER

DATA/ELECTRICAL CHASE

MOUNTING BRACKET FOR CCTV

DATA & ELECTRICAL FOR CCTV

PANEL BOX TO HOUSE:

• SIREN BUTTON

• RPM ANNUNCIATORS

• DURESS BUTTON

• SWITCH FOR LANE LIGHTS

SINGLE DATA FOR CCTV

3N/1R DATA

3N/1T DATA

DUPLEX

QUAD

HEATED FLOOR

MAT

ELECTRICAL FOR

HEATED FLOOR MAT

CPU HANGER

ELEVATION – Interior facing Canada

KEY

ROLLER SHADES

ELEVATIONS

SLOPE ROADWAY UP TO MEET CURB AT BOOTH AND

GRADE DOWN TO EXISTING LEVEL ON BUILDING SIDE.

REPLACE CURBING AS NECESSARY.

Create a gradual hump in roadway so vehicle is angled not more than 3% . Extend hump past booth for easy transition back to grade.

7”

ROADWAY IN LANE 1

CURB CURB

7”

8”

HEIGHT OF CANOPY IS 13’-8”

41’-4”

11’-8”

NEW BOOTH ELEVATION

DIRECTION OF TRAVEL ENTERING THE USA VIA LANE 1

EXTERIOR LIGHTING

BACK DOOR

CAMERA W/MIC

8’-0”

7”

8”

HEIGHT OF CANOPY IS 13’-8”

41’-4”

11’-8”

NEW BOOTH ELEVATION

DIRECTION OF TRAVEL IN OUTBOUND LANE TO CANADA

CAMERA W/MIC

EXTERIOR DUPLEX

HVAC UNIT

EXTERIOR LIGHTING

Slide Number 1
Slide Number 2
Slide Number 3
Slide Number 4
Slide Number 5
Slide Number 6
Slide Number 7
Slide Number 8
Slide Number 9
Slide Number 10

File details come from the government source that posted it. Updated .