47PB0020B0001_Tab_2_Richford_Booth_Replace_SOW_2019_07_02.pdf

PDF 895 KB Posted

Attached to
East Richford LPOE Intrusion Detection System and Refresh Federal contract opportunity
Solicitation number
47PB0020B0001
Issued by
General Services Administration Public Buildings Service Region 1

About this file

This notice describes a construction project for renovations and upgrades at three land ports of entry along the United States-Canada border. The project involves renovating space at the East Richford LPOE for Customs and Border Protection, including new bathrooms, offices, work areas, and security upgrades. Temporary facilities are also required during construction. Replacement of an inspection booth is outlined for the Richford and West Berkshire LPOEs, involving HVAC, electrical, lighting, security systems, and associated site work.

The General Services Administration will award a 100% small business set-aside contract for an estimated value between $1,000,000 and $2,000,000 in November 2019. A pre-bid site visit will be held on October 29th, with bids due on November 18th. The selected contractor must obtain security clearances and provide payment and performance bonds. Interested parties must register in the System for Award Management and monitor the Federal Business Opportunities website for solicitation documents and any amendments.

Richford Booth Replacement Scope of Work

View the file

Other files for this federal contract opportunity

Other files attached to East Richford LPOE Intrusion Detection System and Refresh, newest first.
File Type Posted
AD-101_Rev_1.pdf PDF
Port_Refresh_East_Richford_LPOE_Specifications.pdf PDF
47PB0020B0001Tab_2_West_Berkshire_Booth_Replacement_SOW_2019_07_02.pdf PDF
285-053-002_Port_Refresh_East_Richford_LPOE_dwgs.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

RICHFORD – BOOTH REPLACEMENT PROJECT

FFR 17-1344

LANE 1 - POV LANE 2 – POV

NOT USEDCOMMERCIAL PULLS UP

IN OUTSIDE LANE NOT

REALLY SHOWN.

FIELD MEASUREMENTS

38’-8”

6’ -0

NOTES

• COLUMNS ARE 8” X 8”

• CURB IS 1”-2” ABOVE ROADWAY

• BOOTH STEP IS 3”-3-1/2” ABOVE CURB.

• EXISTING BOOTH IS 4’X8’. 12

’-0

’-0

LANE 1 - POV

LANE 2/ used to park pursuit vehicle

COMMERCIAL

11’-9”

HVAC/ELECTRICAL/DATA CHASE

• HVAC UNIT located on roof of booth under canopy.

• Provide electrical outlet on roof for equipment usage by repair personnel.

• Continue chase horizontally under windows and counter.

• Add vertical chase to ceiling for data and electrical to CCTV in location shown. No exposed conduit.

LIGHTING

• Interior: 2 2X2 LED lights over counter.

• Exterior: LED light over doors and one mounted on side without door. See elevation drawings for locations.

HEATING

• Quick recovery unit.

• Heated Floor Mat sized to the booth floor.

WINDOWS and DOORS

• Level 3, BR Rated glass with tinting.

• Add shades for each window.

COUNTER

• Solid surface material

• Blocking under counter for CPU hanger.

• Minimum of three (3) 2” grommet holes for wire management.

BOOTH ENVELOPE

• Level 3, BR rated material. All exterior piping and connections to be sealed.

CAMERAS AND MICROPHONES

• Install two (2) cameras with microphone capability, or install separate microphone under camera, on booth as shown. They are to be mounted at approximately 60” to 66” – actual height to be determined at time of installation to insure viewing inside vehicle is correct.

STATEMENT OF WORK

EQUIPMENT RE-INSTALLATION AND NEW

• Install panel to house the RPM annunciators (2), the switch to the siren, duress button and switch for lane lights. Wire all items into this panel and label accordingly.

• Add a radio console in booth.

• Replace existing siren with a new siren.

• Add two (2) Cameras and Microphones, can be combined unit or separate.- see note under

“Cameras and Microphones.”

• Add CCTV Monitor (23”) and bracket suspended from ceiling.

SIGNAGE – Refer to drawing for locations.

• Relocate POV sign to a 2” sign post (MINIMUM 8’ above ground) in between the RPM bollards in LANE 1.

• Install three (3) 2” sign posts (MINIMUM 5’ above ground) along LANE 1 prior to the RPM where vehicle is stopped and waiting to be brought forward.

• Install two (2) 2” sign posts (MINIMUM 8’ above ground) along Commercial Lane prior to the RPM where vehicle is stopped and waiting to be brought forward.

RICHFORD – BOOTH REPLACEMENT PROJECT

FFR 17-1344

6’-0”

8’-0”

HVAC/DATA

CHASE

CEILING HATCH

LIGHTING

LIGHTING

COUNTER

RIGHT SIDE

LEFT SIDE

BUILDING

OUTBOUND LANE

CAMERA AND MIC

CAMERA AND MIC

PLAN VIEW

6’-0”

8’-0”

HVAC/ELEC/

DATA CHASE

HVAC/ELECTRICAL/DATA CHASE

• UTILIZE CHASE FOR WIRING

RUNS AND OUTLETS, PANELS

AND DATA BOXES.

COUNTER

1N DATA & 1 DUPLEX

AT CEILING FOR CCTV.

1 DUPLEX BELOW

COUNTER.

3N/1R DATA & 1 QUAD

BELOW COUNTER.

3N/1T DATA & 1 QUAD

BELOW COUNTER.

1 DUPLEX BELOW

COUNTER.

RIGHT SIDE

LEFT SIDE

CPU HANGER

LOCATION.

PANEL BOX TO HOUSE:

• SIREN BUTTON

• RPM ANNUNCIATORS

• DURESS BUTTON

• SWITCH FOR LANE LIGHTS

DATA – 3N/1R AND 3N/1T

DATA – 1N

DUPLEX

QUAD

KEY AND NOTES

PLAN VIEW - ELECTRICAL/DATA

BUILDING

LANE 2

ANGLED WALL

SOLID SURFACE

COUNTER

DATA/ELECTRICAL CHASE

MOUNTING BRACKET FOR CCTV

DATA & ELECTRICAL FOR CCTV

PANEL BOX TO HOUSE:

• SIREN BUTTON

• RPM ANNUNCIATORS

• DURESS BUTTON

• SWITCH FOR LANE LIGHTS

SINGLE DATA FOR CCTV

3N/1R DATA

3N/1T DATA

DUPLEX

QUAD

HEATED FLOOR

MAT

ELECTRICAL FOR

HEATED FLOOR MAT

CPU HANGER

ELEVATION – Interior facing Canada

KEY

ROLLER SHADES

7”

8”

HEIGHT OF CANOPY IS 13’-8”

38’-8”

11’-9”

NEW BOOTH ELEVATION

DIRECTION OF TRAVEL ENTERING THE USA VIA LANE 1

EXTERIOR LIGHTING

BACK DOOR

CAMERA W/MIC

8’-0”

7”

8”

HEIGHT OF CANOPY IS 13’-8”

41’-4”

11’-8”

NEW BOOTH ELEVATION

DIRECTION OF TRAVEL IN OUTBOUND LANE TO CANADA

CAMERA W/MIC

EXTERIOR DUPLEX

HVAC UNIT

EXTERIOR LIGHTING

Install two (2) 2” sign posts (MINIMUM 8’ above ground) along Commercial Lane prior to the RPM where vehicle is stopped and waiting to be brought forward.

SIGNAGE

Relocate POV sign to a 2” sign post (MINIMUM 8’ above ground) in between the RPM bollards in LANE 1.

Install three (3) 2” sign posts (MINIMUM 5’ above ground) along LANE 1 prior to the RPM where vehicle is stopped and waiting to be brought forward.

Slide Number 1
Slide Number 2
Slide Number 3
Slide Number 4
Slide Number 5
Slide Number 6
Slide Number 7
Slide Number 8
Slide Number 9
Slide Number 10
Slide Number 11

File details come from the government source that posted it. Updated .