472.22420.TAP_BaragaCFRoofReplacement_Addendum 2_Issued_241127.pdf

PDF 182 KB Posted

Attached to
472/22420. TAP; Baraga CF - Housing Unit 8 Roof Replacement
Solicitation number
RFQ 171 250000000042 3
Issued by
Baraga County, Michigan

About this file

This addendum document pertains to the Baraga Correctional Facility Housing Unit 8 Roof Replacement project, issued by Michigan DTMB (Department of Technology, Management & Budget) and MDOC (Department of Corrections). Addendum No. 2, dated November 27, 2024, modifies the original contract documents dated September 30, 2024, and does not change the bid date of Wednesday, December 4, 2024. The addendum introduces new specifications for steel siding materials and revises existing architectural details and drawings. Key modifications include the addition of Section 074619 (Steel Siding) to the General Project Manual, revision of Architectural Note 5 on drawing A-101 to specify blow-in fiberglass insulation providing R-20 total insulation throughout the attic space, and revision of Details 2 and 4 on drawing A-301 to change all references from vinyl fascia and soffit to steel fascia and soffit.

The steel soffit and fascia specifications require galvanized steel products complying with ASTM A653/A653M with G90 coating, featuring 16-inch exposure in V-grooved, double-board style soffit with minimum 29-gauge thickness and smooth fascia with pencil ribs (if exceeding 6 inches) in minimum 26-gauge thickness. Acceptable manufacturers include EDCO Products Inc., Gentek Building Products Inc., Norandex, Quality Edge, Rollex Corporation, and United States Seamless Inc. The specification includes a 15-year warranty period for chalking and fading from the date of Substantial Completion, requirements for perforated soffit ventilation, and provisions for hot-dip galvanized-steel fasteners with color-matched prefinished options where exposed. Installation must comply with manufacturer specifications and include protective measures against galvanic action where dissimilar metals contact steel components.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

ADDENDUM NO. 2

DATE: November 27, 2024

PROJECT: Baraga Correctional Facility Housing Unit 8 Roof Replacement

DTMB FILE NO.: 472/22420.TAP

OWNER: MI DTMB/DOC

BID DATE: Wednesday, December 4, 2024 ** THIS ADDENDUM DOES NOT CHANGE

THE BID DATE

The following shall be incorporated into the Contract Documents dated 30 SEPT 2024.

GENERAL

PROJECT MANUAL

074619 STEEL SIDING

This specification section is added to the documents to provide requirements for steel fascia and soffit as noted on revised details on A-301. (see below).

DRAWINGS

A-101 ROOF PLAN

Revise Architectural note 5 to read as follows: Blow-in fiberglass insulation to add a total of R-20 insulation throughout the attic space.

A-301 DETAILS

Regarding Detail 2 and Detail 4, all references to vinyl fascia and soffit are to be revised to steel fascia and soffit.

End of Addendum No. 2

DTMB/MDOC

Baraga Correctional Facility Housing Unit 8 Roof Replacement DTMB No.: 472/15244.TAP OHM File No.: 7136-21-0030

STEEL SIDING

074619 - Page 1 of 2

Addendum 2 - 11/27/2024

Copyright © 2024 by the American Institute of Architects. Warning: This AIA MasterSpec-based document is protected by U.S. Copyright Law and International Treaties.

It was created by "OHM Advisors" for "Baraga Correctional Facility Housing Unit 8 Roof Replacement". A valid, current MasterSpec license is required for editing and use of this document for any other project.(25265)

SECTION 074619 - STEEL SIDING

PART 1 - GENERAL

1.1 SUMMARY

A. Section includes steel soffit and fascia.

1.2 ACTION SUBMITTALS

A. Product Data: For each type of product.

B. Samples: For steel soffit and fascia including related accessories.

1.3 CLOSEOUT SUBMITTALS

A. Maintenance data.

1.4 WARRANTY

A. Special Warranty: Manufacturer agrees to repair or replace products that fail in materials or workmanship within specified warranty period.

1. Warranty Period for Chalking and Fading: 15 years from date of Substantial Completion.

PART 2 - PRODUCTS

2.1 STEEL SOFFIT AND FASCIA

A. Steel Soffit and Fascia: Formed product made from galvanized steel complying with ASTM A653/A653M, G90 coating.

1. Manufacturers: Subject to compliance with requirements, available manufacturers offering products that may be incorporated into the Work include, but are not limited to, the following:

a. EDCO Products Inc.

b. Gentek Building Products, Inc.

c. Norandex.

d. Quality Edge.

e. Rollex Corporation.

f. United States Seamless Inc.

B. Soffit Pattern: 16-inch exposure in V-grooved, double-board style.

http://www.specagent.com/LookUp/?ulid=9167&mf=04&src=wd

DTMB/MDOC

Baraga Correctional Facility Housing Unit 8 Roof Replacement DTMB No.: 472/15244.TAP OHM File No.: 7136-21-0030

STEEL SIDING

074619 - Page 2 of 2

Addendum 2 - 11/27/2024

Copyright © 2024 by the American Institute of Architects. Warning: This AIA MasterSpec-based document is protected by U.S. Copyright Law and International Treaties.

It was created by "OHM Advisors" for "Baraga Correctional Facility Housing Unit 8 Roof Replacement". A valid, current MasterSpec license is required for editing and use of this document for any other project.(25265)

C. Fascia: Smooth with pencil ribs if more than 6"

D. Texture: Smooth.

E. Ventilation: Provide perforated soffit.

F. Nominal Thickness Soffit: min. 29 gauge.

G. Nominal Thickness Fascia: min. 26 gauge.

H. Finish: Manufacturer's standard.

1. Colors: As selected by Architect from manufacturer's full range of colors.

2.2 ACCESSORIES

A. Fasteners:

1. For fastening galvanized steel, use hot-dip galvanized-steel fasteners. Where fasteners are exposed to view, use prefinished galvanized-steel fasteners in color to match item being fastened.

PART 3 - EXECUTION

3.1 INSTALLATION

A. General: Comply with manufacturer's written installation instructions applicable to products and applications indicated unless more stringent requirements apply.

B. Where steel siding contacts dissimilar metals, protect against galvanic action by painting contact surfaces with primer or by applying sealant or tape or installing nonconductive spacers as recommended by manufacturer for this purpose.

3.2 ADJUSTING AND CLEANING

A. Remove damaged, improperly installed, or otherwise defective materials and replace with new materials complying with specified requirements.

B. Clean finished surfaces according to manufacturer's written instructions and maintain in a clean condition during construction.

END OF SECTION 074619

ADDENDUM NO. 2
GENERAL
PROJECT MANUAL
DRAWINGS

File details come from the government source that posted it. Updated .