472-24052.JGH Statewide Perimeter Repair-Replacement - Lakeland Correctional - Bid Set.pdf

PDF 2 MB Posted

Attached to
472/24052. JGH; Lakeland CF - Perimeter Fence Repair/ Replace
Solicitation number
RFQ-171-250000000552-3
Issued by
Barry County, Michigan

About this file

This is a bid set of construction documents from the State of Michigan Department of Technology, Management and Budget (State Facilities Administration, Design and Construction Division) for the Lakeland Correctional Facility Statewide Perimeter Repair/Replacement project located in Coldwater, Michigan. The project involves comprehensive fencing enhancements, including installing new anti-climb razor mesh panels, removing and reinstalling existing fencing around various facility areas, reinforcing fence supports, repairing fence fabric, and modifying gates and perimeter security infrastructure. The bid set is dated 07/18/2025 and was prepared by Matrix Consulting Engineers, Inc., with detailed site plans, fencing details, and specific enhancement locations mapped across the facility's administrative and main campus areas.

The project scope includes multiple specific fencing modifications such as installing new 'B' fence over roofs, adding detainer hook razor ribbon with 12" loop spacing, reinforcing existing fence posts, repairing damaged fence sections, and creating new man gates. The technical specifications outline precise installation requirements, including concrete footings, steel post installations, wire connections, and specific placement of razor mesh and anti-climb features. The documents provide comprehensive technical details for contractors, including scaled drawings of fence panel replacements, roof fence details, gate modifications, and exterior fence reinforcement strategies, indicating a thorough approach to upgrading the correctional facility's perimeter security infrastructure.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

T-000

BTT

JFS

file no.

checked by drawn by consultant issue date index no.

contract order no.

consultant job no.

24233.00 sheet title

M a t r ix

472/24052.JGH

D

EP

A R

TM

EN

T O

F

TE

C H

N O

LO

G

Y , M

A N

A G

EM

EN

T A

N D

B U

D G

ET

ST

A

TE

O F

M

IC

H

IG

A N

R O

B

ER

T C

. H A

LL

, R

A , N

C A

R B

, D

IR

EC

TO

R

ST

A

TE

F

A C

IL

IT

IE

S

A D

M

IN

IS

TR

A

TI

O N

D

ES

IG

N

A N

D C

O N

ST

R

U C

TI

O

N D

IV

IS

IO

N

BID SET 07/18/2025

1 1 22 22 21 1 1

22 22

2111 5

2 1 2 1 1

4 4 4 4

13'

18'

FENCING KEY NOTES

PROVIDE AND INSTALL NEW ANTI-CLIMB RAZOR MESH PANEL PER DETAIL 1

ON SHEET C-200.

REMOVE EXISTING VERTICAL RAZOR RIBBON. INSTALL NEW ANTI-CLIMB

RAZOR MESH PANEL PER DETAIL 1 ON SHEET C-200.

REMOVE EXISTING DAMAGED FIRST PANEL OF FENCING IN EACH DIRECTION

OF CORNER AT LOCATION SHOWN. INSTALL NEW FENCE PANELS PER

DETAILS 2 & 3 ON SHEET C-200.

INSTALL NEW SUPPORT POST AT INDICATED LOCATION TO REINFORCE

LEANING "A" FENCE. SEE DETAILS 4, 5, AND 6 ON SHEET C-200 FOR MORE

INFORMATION.

REPAIR EXISTING DAMAGED FENCE FABRIC NEAR LOCATION SHOWN PER

DETAIL 7 ON SHEET C-200.

INSTALL NEW RAZOR MESH PANELS TO TOP OF EXISTING DOUBLE GATES

PER DETAIL 8 ON SHEET C-200.

INSTALL WELDED PLATES ONTO SLIDING SALLYPORT GATES TO CLOSE GAP

BETWEEN BOTH EXISTING FABRICS. SEE DETAIL 9 ON SHEET C-200.

C-100

BTT

JFS

SCALE: 1" = 80'-0"

200 10 40 80 160 200

N SITE PLAN - FENCING ENHANCEMENTS

file no.

checked by drawn by consultant issue date index no.

contract order no.

consultant job no.

24233.00 sheet title

M a t r ix

472/24052.JGH

D

EP

A R

TM

EN

T O

F

TE

C H

N O

LO

G

Y , M

A N

A G

EM

EN

T A

N D

B U

D G

ET

ST

A

TE

O

F M

IC

H

IG

A

N

R O

B

ER

T C

. H A

LL

, R

A , N

C A

R B

, D

IR

EC

TO

R

ST

A

TE

F

A C

IL

IT

IE

S

A D

M

IN

IS

TR

A

TI

O N

D

ES

IG

N

A N

D C

O N

ST

R

U C

TI

O

N D

IV

IS

IO

13'

18'

EXISTING 'A' FENCE TO BE

REMOVED/REINSTALL AFTER

ROOF WORK IS COMPLETED.

NEW MAN GATE

EXISTING 'B' FENCE TO BE

REMOVED/REINSTALLED AFTER ROOF

WORK IS COMPLETED. INSTALL NEW

FENCE FABRIC OVER CHIMNEY.

INSTALL NEW 'B' FENCE OVER

ROOF AT LOCATION SHOWN

file no.

checked by drawn by consultant issue date index no.

contract order no.

consultant job no.

24233.00 sheet title

M a t r ix

472/24052.JGH

D

EP

A R

TM

EN

T O

F

TE

C H

N O

LO

G

Y , M

A N

A G

EM

EN

T A

N D

B U

D G

ET

ST

A

TE

O F

M

IC

H

IG

A N

R O

B

ER

T C

. H A

LL

, R

A , N

C A

R B

, D

IR

EC

TO

R

ST

A

TE

F

A C

IL

IT

IE

S

A D

M

IN

IS

TR

A

TI

O N

D

ES

IG

N

A N

D C

O N

ST

R

U C

TI

O

N D

IV

IS

IO

N

BID SET 07/18/2025

N SITE PLAN - ADMIN. BUILDING FENCING ENHANCEMENTS

SCALE: 1" = 30'-0"

01 5 20 40 75

BTT

JFS

C-101

FENCE FABRIC - RAZOR MESH

SCALE: N.T.S.1

EXISTING FABRIC

EXISTING

DETECTION CABLE

PROVIDE AND INSTALL STAINLESS STEEL TIE WIRES.

TIES SHALL BE TWIST TO SECURE THE RAZOR MESH

TO FENCE. INSTALL AT 12" O.C. WITH 9 GAUGE AND NO

LESS THAN 5 COMPLETE TWISTS.

NOTES:

(3) EXISTING

ROWS OF DETAINER

HOOK RAZOR RIBBON

EXISTING

1.660" MID RAIL

RAZOR MESH 24"

WIDE MIN. ON SECURE

SIDE OF FENCE

EXISTING

TENSION BANDS

EXISTING

TENSION BARS

EXISTING

1.660" BOTTOM RAIL

EXISTING

1.660" TOP RAIL

~10'

~10'

CORNER OF INTERIOR

"A" FENCE

REMOVE ALL EXISTING COMPONENTS

OF FENCING PANEL & REINSTALL ALL

NEW ASSOCIATED PARTS

2 FENCE PANEL - REPLACEMENT DETAIL - AERIAL VIEW

SCALE: N.T.S.

REMOVE ALL EXISTING COMPONENTS

OF FENCING PANEL & REINSTALL ALL

NEW ASSOCIATED PARTS

NEW

FENCE FABRIC

(TYP.)

NEW 1.660"

MID RAIL

NEW 1.660"

BOTTOM RAIL

NEW 1.660"

TOP RAIL

x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x

EXISTING DETAINER

HOOK RAZOR RIBBON

NEW 4" DIA.

FENCEPOST (TYP)

NEW CAP FOR

4" DIA. VERTICAL FENCEPOST

(TYP.)

~10'

(PANEL WIDTH MAY VARY)

3 FENCE PANEL - REPLACEMENT DETAIL

SCALE: N.T.S.

NEW 18" DIA.

CONCRETE FOOTING (TYP)

12'

FINISHED GRADE EXISTING SALLYPORT

GATES

EXISTING FENCE

FABRIC

x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x

NEW MINI MESH

ANTI-CLIMB

x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x

EXISTING FENCE

FABRIC

NEW 4" TALL WELDED

PLATE TO COVER BREAK

IN FENCE FABRICS (TYP.)

EXISTING DETAINER

HOOK RAZOR RIBBON

HOG RING TO CHAIN LINK

FABRIC BOTH SIDES

SOFT TAPPING SCREWS

BOTH SIDES

SCALE: N.T.S.

FENCE REINFORCEMENT DETAIL - TOP ATTACHMENT4

EXISTING "A" FENCE

EXISTING RUSTED POST

10'-0" TYP.

SCALE: N.T.S.

FENCE REINFORCEMENT - EXTERIOR FENCE DETAIL

GRADE

40 36 36

31 28

BETWEEN FENCES

NEW 18" DIA x 4'-8"

CONCRETE FOOTING,

TYP

INSTALL NEW 4" DIA

STEEL COLUMNS

INSTALL NEW MINI

MESH ANTI CLIMB TO

BOTH SIDES OF NEW

SUPPORTS OUTSIDE

INSIDE

EXTERIOR FENCE

INTERIOR FENCE

CONTRACTOR TO PROVIDE ALL STAINLESS STEEL

HARDWARE. ALL BOLTS SHALL INCLUDE FLAT AND

LOCK WASHERS.

NOTES:

EXISTING

1.660" TOP RAIL

EXISTING

1.660" MID RAIL

EXISTING

1.660" BOTTOM RAIL

EXISTING FABRIC

WEAVE

NEW FABRIC

TOGETHER

TWIST ENDS ON

NEW FABRIC

(ALL SIDES)

TENSION RODS

(ALL SIDES) WELD

AND GALVANIZE

ALL BARS/FABRIC

EXISTING

1.660" TOP RAIL

EXISTING

1.660" MID RAIL

EXISTING

1.660" BOTTOM RAIL

NEW 1.660" VERTICAL

SUPPORT RAIL

EXISTING FABRIC

REVIVE

NEW FABRIC

TOGETHER

INSTALL

TENSION BAR

(REMOVE UPON

COMPLETION OF

REPAIRS)

FENCE FABRIC REPAIR

SCALE: N.T.S.7

INSTALL

TENSION BAR

(REMOVE UPON

COMPLETION OF

REPAIRS)

EXISTING "A" FENCE

10'-0" TYP.

SCALE: N.T.S.

FENCE REINFORCEMENT DETAIL - MIDRAIL ATTACHMENT5

CLAMP NEW POST TO THE

MIDDLE RAILS OF THE

EXISTING FENCE SYSTEM

EXISTING RUSTED POST

8 RAZOR MESH ANTI-CLIMB ON EXISTING DOUBLE GATES

SCALE: N.T.S.

9 WELDED PLATE INSTALLATION ON EXISTING SALLYPORT GATES

SCALE: N.T.S.

EXISTING DOUBLE

GATES

x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x

NEW MINI MESH

ANTI-CLIMB

x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x

EXISTING DETAINER

HOOK RAZOR RIBBON

FINISHED GRADE EXISTING FENCE

FABRIC

EXISTING FENCE

FABRIC

BTT

JFS

C-200 file no.

checked by drawn by consultant issue date index no.

contract order no.

consultant job no.

24233.00 sheet title

M a t r ix

472/24052.JGH

D

EP

A R

TM

EN

T O

F

TE

C H

N O

LO

G

Y , M

A N

A G

EM

EN

T A

N D

B U

D G

ET

ST

A

TE

O

F M

IC

H

IG

A

N

R O

B

ER

T C

. H A

LL

, R

A , N

C A

R B

, D

IR

EC

TO

R

ST

A

TE

F

A C

IL

IT

IE

S

A D

M

IN

IS

TR

A

TI

O N

D

ES

IG

N

A N

D C

O N

ST

R

U C

TI

O

N D

IV

IS

IO

N

BID SET 07/18/2025

STRAIGHT CORNER

BA

PARTIAL FABRIC SECTIONVERTICAL FABRIC SECTION

EXISTING ROOF

SCALE: N.T.S.

ROOF FENCE DETAIL - 'B' FENCE1

+/- 27' +/- 27'

ADMIN. BUILDING

6" POST 6" POST

SUPPORT POST

THRU PEAK

GRADEGRADE

ADD NEW 31" DETAINER

HOOK RAZOR RIBBON

w/ 12" LOOP SPACING

20' 53'

LOADING DOCK

SCALE: N.T.S.

EXTERIOR FENCE DETAIL2

NEW EXTERIOR

"B" FENCE

ADD DETAINER HOOK

RAZOR RIBBON w/ 12"

LOOP SPACING, TYP

x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x

ADD DETAINER HOOK

RAZOR RIBBON w/ 12"

LOOP SPACING, TYP

ADD INSTABARRIER

RAZOR RIBBON w/ 12"

LOOP SPACING, TYP

B

OUTSIDE

x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x

INSTALL NEW

SHAKER WIRE

6'-0"

EQ

MATCH

ADJACENT

FENCE

EQ

1/4" PLATE STEEL

GUSSET (TYP.)

FENCE

SUPPORT POST (TYP)

9 GAUGE 2" CHAIN LINK

FABRIC GATES & FENCE

4'-0" X X'-X"

MAN GATE

6'-0"

1 ROLL 36" NOM. DIAM.

RAZOR RIBBON

WHERE INDICATED.

SEE SITE PLAN E-200.

C201

STEEL PLATE

AROUND BOTTOM

OF GATE - REFER

TO DETAIL ON SITE.

KEY NOTES

USE (1) PIECE OF FABRIC AN EACH GATE.

3 TYPICAL MAN GATE DETAIL

SCALE: N.T.S.

1'-0"

4'-0"

4 TYPICAL FENCE FOOTING

SCALE: N.T.S.

6" OF SOIL

WIRE TIES TO CONNECT

5/6" STEEL ROD TO PIER,

TYP.

CONCRETE FOOTING

TYP., 18" DIA.

6" DEEP MDOT 23A

CRUSHED LIMESTONE

5'-0"

C201

FINISHED GRADE

EXISTING

DOUBLE GATE LATCH

MODIFICATIONS TO

MAN GATE LOCK

SCALE: N.T.S.

CUT SECTION INTO

FENCE TO ALLOW

EXCESS TO LOCK FROM

BOTH SIDES OF GATE

4"

BTT

JFS

C-201 file no.

checked by drawn by consultant issue date index no.

contract order no.

consultant job no.

24233.00 sheet title

M a t r ix

472/24052.JGH

D

EP

A R

TM

EN

T O

F

TE

C H

N O

LO

G

Y , M

A N

A G

EM

EN

T A

N D

B U

D G

ET

ST

A

TE

O

F M

IC

H

IG

A

N

R O

B

ER

T C

. H A

LL

, R

A , N

C A

R B

, D

IR

EC

TO

R

ST

A

TE

F

A C

IL

IT

IE

S

A D

M

IN

IS

TR

A

TI

O N

D

ES

IG

N

A N

D C

O N

ST

R

U C

TI

O

N D

IV

IS

IO

T000-2423300-LAKE-T-000
C100-2423300-LAKE-30x42
C101-2423300-LAKE-30x42
C200-2423300-LAKE-30x42
C201-2423300-LAKE-30x42

File details come from the government source that posted it. Updated .