472_19527_SMD Addendum_1.pdf

PDF 2 MB Posted

Attached to
472/19527. SMD; Bellamy Creek CF - ADA Egress Ramps
Solicitation number
RFQ 171 260000000310 2
Issued by
Huron County, Michigan

About this file

This is Construction Bid Addendum No. 1 issued by the Michigan Department of Technology, Management and Budget (DTMB), State Facilities Administration Design and Construction Division for the Bellamy Creek Correctional Facility Housing Unit 2 ADA Ramps and Improvements project. The addendum, issued June 4, 2026, with a bid opening date of June 10, 2026, provides clarifications and modifications to the original bidding documents. Key modifications include alterations to cells 132, 133, 134, and 135; clarification that stainless steel desk dimensions are 30" x 18"; extended epoxy flooring in front of ramps and adjacent to showers with added stainless steel gates; replacement of epoxy flooring specifications with resinous flooring (Stonhard product) for shower rooms and ramps; addition of a Class A flammability-rated plastic dust barrier under existing stairs; and deletion of work related to exhaust fan replacement. The project professional is Straub Pettitt Mann Architecture with project director Scott DeKorte. Reissued drawing sheets include A1, A2, and A5, with detailed specifications for cell modifications, shower room renovations, and ramp improvements throughout the Lower B-Wing corridor.

The addendum addresses eight items with specific clarifications regarding materials, fixtures, and construction logistics. The Owner will furnish combi toilet-sink units and reusable shower heads and controls from existing demolished showers, with removed toilets and sinks to be turned over to the Facility. The project specifications include a Folding Shower Seat (Norix Group Ironman Detention Furnishings ADA shower seat) and require ADA compliance throughout. Contractors may value engineer equal epoxy products to the specified Stonhard standard. The Facility will maintain one available escort during construction with a second available only by special arrangement with 48 hours' notice. Standard working hours are Monday through Friday, 7 a.m. to 3:30 p.m., though the Facility demonstrates flexibility. The Facility is working to maintain a vacant Lower B-Wing during construction to minimize operational disruption. Acknowledgement of this addendum is required in the bid submission; failure to acknowledge may result in bid rejection.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

DTMB-0414 (Rev 6/16)

DEPARTMENT OF TECHNOLOGY, MANAGEMENT AND BUDGET

State Facilities Administration Design and Construction Division

CONSTRUCTION BID ADDENDUM NO. 1

This form identifies an Addendum to Bidding Documents, and incorporates interpretations or clarifications, modifications, acceptance of proposed “or equal” materials, and other information into the Bidding Documents.

Addenda will be numbered by the Professional and distributed through www.michigan.gov/SIGMAVSS as an attachment.

TO:

ALL BIDDERS

DATE ISSUED

June 4, 2026

PROJECT NAME

Bellamy Creek Correctional Facility – Housing Unit 2 ADA ramps and improvements

FILE NUMBER

472/19527.SMD

PROFESSIONAL

Straub Pettitt Mann Architecture Richard Mann

PROJECT DIRECTOR

Scott DeKorte

BID OPENING DATE:

June 10, 2026

ADDENDUM ITEMS:

Reissued are sheets A1, A2, and A5

Item 1:

Refer to reissued sheet A1. Alteration will be made to cell numbers: 132, 133, 134 and 135.

Item 2:

Refer to reissued sheet A2. Clarified dimensions on cell stainless steel desk to be 30” x 18”.

It

Item 3:

Refer to reissued sheet A5. Extended epoxy flooring in front of the ramps and adjacent to the showers, to be the width of ramp and to extend past the existing drinking fountain.

Added stainless steel gates to the new showers. Added details 6/A5 and 7/A5 of new stainless-steel gates.

Shower walls to receive a spray-on waterproofing base coat compatible with the top epoxy high-performance coating. Extend high-performance coating on existing walls in shower room, including existing shower.

Shower floor to receive a resinous flooring over new compatible mud bed. Extend resinous flooring to trench drains, across room to janitor closet and into existing shower, then out into the Wing corridor.

Labeled grab bars, shower seat, shower heads and shower controls. Eliminated soap dish, shower curtains and track.

Item 4:

Refer to sheets A3 and A4 (not reissued). Add a Class A flammability rated plastic sheet on the underside of the existing stair to the upper level for a dust barrier.

The notes that mention epoxy flooring shall be changed to resinous flooring.

Item 5:

Refer to Sheet MP2 (not reissued):

Delete all work related to replacing the existing exhaust fan. The exhaust fan was replaced a few years ago and meets current MDOC standards.

The shower heads, shower controls, combi toilet-sink units will be furnished by the Owner for this project.

http://www.michigan.gov/SIGMAVSS

Item 6:

Clarifications:

1. Reuse the existing shower control buttons and shower heads from the existing demolished showers. The Facility has a spare set so that both new showers will have a high and low shower head.

2. Turn over removed toilets and sinks to the Facility.

3. The Owner will furnish the combi toilet-sink units. The Owner is ordering them now in an effort to not delay the construction by waiting on the units to be ordered by the Contractor after contract award.

4. The Facility is working to have the entire Lower B-Wing vacant of inmates during the time of construction.

5. One escort will be made available during the project. A second escort may be made available only through special arrangement with the Facility at least 48 hours in advance and only for a day or two at a time.

6. The Facility is flexible with working hours; however, generally they are used to Monday through Friday 7 am to 3:30 pm.

Item 7:

Specifications Section 102813.63 Detention Toilet Accessories:

Add Folding Shower Seat: Norix Group Ironman Detention Furnishings ADA shower seat. Shower seat shall be recess mounted, stainless steel with ADA compliant “L” shaped seat. Compliant with ADA 4.21.3 and 4.26.3, and ANSI 610.3.2 and 610.4.

Item 8:

Questions:

o Please clarify the dimensions for the desk. See addendum item 2.

o Drawing sheet A5 shows CMU with waterproofing with nothing else on the walls. The drawing also shows Stonhard overlayment on the floor at the shower drain. See addendum item 3.

o Lighting in noted on the architectural drawing. There are no electrical plans. Will we be using the same circuit and wiring that the existing lighting is connected to? Yes. The new fixtures are a one-for-one replacement/upgrade.

o The drawings call for an epoxy floor coating at the new ramp, the specs for the resinous flooring only call fro Stonhard which was assumed to only be used at the shower rooms. Will the Stonhard flooring be used at the ramp or will a different epoxy/resinous product be used at the ramp? The intent is to continue the resinous flooring from the shower room out into the corridor space and up the ramp. Also see addendum item 4.

o The drawings are shower a mud bed running to the French drains and no finish over this such as epoxy, tile, etc. Having a mudbed only will not create and finish look and is meant as an underlayment, will you please advise if that is what you are looking for or if a flooring product will need to go over the mud bed? The resinous flooring will extend to the edge of the trench drain. See revisions made to sheet A5 in addendum item 3.

o Can we value engineer an equal epoxy product to the Stonhard product? Yes, the specifications use Stonhard as the “Standard of Design.”

Attached herewith are the Pre-Bid Attendance sign-in sheet and the drawing sheets A1, A2 and A5.

Photos are included under a separate file.

s

ACKNOWLEDGEMENT: This Addendum must be acknowledged by the Bidder in the space provided in the Bid Summary and Bid Form. Failing to acknowledge Addenda may be cause for the Bid to be rejected. Addenda will become part of the Contract Documents.

PROFESSIONAL: DATE

Richard Mann, Straub Pettitt Mann Architecture June 4, 2026

APPROVED BY:

Scott DeKorte DATE June 4, 2026

A2

A5

A3

UP

INMATE

ALTERNATE 1

INMATE

INMATE

INMATE

INMATE

INMATE

INMATE

INMATE

INMATE

INMATE

INMATE

INMATE

INMATE

INMATE

INMATE

INMATE

INMATE

INMATE

INMATE

INMATE

INMATE

INMATE

INMATE

INMATE

INMATE

INMATE

INMATE

INMATE

INMATE

INMATE

INMATE

INMATE

INMATE

INMATE

INMATE

INMATE

INMATE

INMATE

INMATE

INMATE

INMATE

INMATE

INMATE

INMATE

INMATE

INMATE

INMATE

KITCHENETTE KITCHENETTE

STORAGE GAMEROOM

CORRIDOR

CORRIDOR

CONTROL

LEVEL

CONTROL

LEVEL

INMATE

LIBRARY

DAY

ROOM

CORRIDOR

OFFICE OFFICE OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

MECHANICAL

DAYROOM

CORRIDOR

ELECTRICAL

COSTIC

RM

INMATE

ALTERNATE 1

INMATE

ALTERNATE 1

INMATE

ALTERNATE 1

INMATE

INMATE

INMATE

INMATE

INMATE

INMATE

INMATE

INMATE

INMATE

INMATE

UP

RA

M P

B. W

IN

G C

ORR

ID

OR A. W

ING CORRIDOR

OBSERVATION

EXITEX

IT

EXISTING RECREATION COURTYARD

TO REMAIN

FL

OOR

IN

FIL

L

CODE COMPLIANCE:

MICHIGAN REHABILITATION CODE FOR EXISTING BUILDINGS 2021

MICHIGAN MECHANICAL CODE 2021

MICHIGAN PLUMBING CODE 2021

NATIONAL ELECTRIC CODE 2023

LIFE SAFETY CODE: NFPA 101-2012

ALTERATION LEVEL 2

USE GROUP:

1-3 CONDITION IV

EXISTING DETENTION AND CORRECTIONAL

CONSTRUCTION TYPE:

2B

II (0,0,0)

NUMBER OF STORIES: 2

TOTAL BUILDING AREA: 18018.23 sf AREA OF RENOVATIONS: 12092.12 sf

OCCUPANCY: 250

BUILDING FULLY SPRINKLED.

NOTE: AT COMPLETION OF ALL CONSTRUCTION ACTIVITIES, THE

CONTRACTOR SHALL CLEAN AREA OF CONSTRUCTION FROM TOP TO BOTTOM INSIDE,

INCLUDING BUT NOT LIMITED TO FLOORS EQUIPMENT, FURNITURE,

DOORS, WINDOWS, PLUMBING FIXTURES, AND LIGHT FIXTURES.

RE

NOVATE

SHOW

ER

S

RENOVATE CELLS BASE BID

STARC TEMPORARY WALL/

OR NON COMP. PLYWOOD

AND STEEL STUD

P e t t i t t Y a s t e

S t r a u b

200S

LAWSON,C MICHIGAN

UITE

48017-1311

F A X248-658-7781 248-658-7777 P H O N E

C850 NORTH ROOKS ROAD

PL

UR

IB

U

E S

U N U

M

C I

R C

U M

S P

I C

E

S I

Q U

E R

E I S

P E

N I

N S

U L

A M

A M

OE

N

A M

D

EP

A R

TM

EN

T O

F

TE

C H

N O

LO

G

Y , M

A N

A G

EM

EN

T A

N D

B U

D G

ET

ST

A

TE

O F

M

IC

H

IG

A N

A D

A M

P . L

A C

H , R

A , D

IR

EC

TO

R

ST

A

TE

F

A C

IL

IT

IE

S

A D

M

IN

IS

TR

A

TI

O N

D

ES

IG

N

A N

D C

O N

ST

R

U C

TI

O

N D

IV

IS

IO

N

A1

ADDENDUM No.1 6/4/2026

RELEASED FOR BIDS 5/15/2026

100% OWNER REVIEW 5/14/2026

90% OWNER REVIEW 3/30/2026

RELEASED FOR REBID 2/9/2022

REVISED FOR PERMITTING 10/18/2022

RELEASED FOR BIDS 9/1/2022

HOUSING UNIT 2 FLOOR PLAN

FILE NO: 472/19527. SMD

ACCT NO: 472 IBC MAINTPROJ

1727 BLUEWATER HWY

IONA, MI 48846

BELLAMY CREEK

CORRECTIONAL FACILITY

HOUSING UNIT 2

ADA RAMPS AND

IMPROVEMENT

LOWER AND CORE LEVEL PLAN

SCALE: 3/32" = 1'-0"

AutoCAD SHX Text

PROJECT NUMBER 2013

2"

ADA COMPLIANT COMBY UNIT

GRAB BAR

EXT.BED

M A

X 3'

-0

M

IN

'-9

3'-6"

2' -1

1"

1'-35 8"

3' -4

EXT. FINNED TUBE

RAD COVER.

M A

X 3'

-5

M

IN

'-3

2' -4

7"

1'-

18"X36" POLISHED

STAINLESS STEEL

MIRROR

REPAINT CEILING, TYP.

REPAINT WALLS, TYP.

3'-5"

MAX. 9"

MIN. 7"

INSTALL TOILET PAPER HOLDER IN

EXISTING CMU WALL. CORE DRILL APPROX. 5"Ø HOLE,

APPROX 4 1/2" DEEP (VERIFY REQUIREMENTS WITH PRODUCT

TO BE INSTALLED). STACK UNITS ON OPPOSITE SIDES OF WALL.

PATCH CMU AT NEW OPENING AND BACKSIDE.

EXT. PERF. ENCLOSURE PLATE

NOTE: REMOVE EXISTING ANCHORS AT

REMOVE ITEMS AND PATCH HOLES

FLUSH WITH WALL FACES.

ANTI-LIGATURE

PLATE THIS SIDE

ANTI-LIGATURE

PLATE THIS SIDE

T.P. HOLDER

OPP. CELL

T.P. HOLDER

'-0

1'-6"

3'-35

8" NEW 30" X 18"

STAINLESS STEEL

12" X 12" LOCKERS

RELOCATED

SEAL BETWEEN MIRROR

AND CMU ALL AROUND

SECURITY HEAD SS SCREWS

INTO EXPN ANCHORS.

2' -6

SEAL BET. DESK

AND CMU

ALL AROUND

SEAL BETWEEN COMBY

UNIT AND CMU. ALL AROUND.

SEAL BETWEEN COMBY

UNIT AND FLOOR.

8"

LOCKER BASE

RELOCATED

THRU BOLT DESK

AND LOCKERS W/

MIN. 3 8"Ø BOLTS.

CUT OFF EXCESS

THREADS AND WELD

TIGHTENED NUT TO

BOLT

2"

1'-6

2'-6"

2'-6"

2"2"

" 2"

1'-6"

FABRICATE FROM 10 ga STAINLESS STEEL

NOTE:

DEGREASE AND #4 BRUSH FINISH POWDER COAT

GRIND AND DEBURR ALL SHARP EDGES.

ALL SHEET METAL BREAKS 90 DEGREES WITH 0.06 INNER

RADIUS.

1/2" DIAMETER HOLES FOR 3/8" FASTENERS

1'-

2'-6"

MOUNT DESKS BACK TO BACK USE 3/8"

STEEL THROUGH BOLTS. TACK WELD NUT TO

BOLT. CUT OFF EXCESS BOLT THREADS

REMOVE EXISTING CONC. DESK

REMOVE EXISTING CONC. STOOL

SAW CUT CMU WALL

4'-8" (AREA TO REMOVE)

1'-

2'

-0

RECONSTRUCT OPENING WITH

NEW 6" CMU GROUTED SOLID

AND HORIZONTAL JOINT REINF.

EXISTING STEEL BED PLANK AND SKIRT TO REMAIN

#4 DOWELS X MIN. 12" LONG

VERTICAL AND HORIZONTAL, TYPICAL AT

5 LOCATIONS

PATCH EXISTING SLEEVE THRU

WALL WITH CMU OR GROUT

EXISTING BED TO REMAIN

REMOVE EXISTING GRAB

BAR

REMOVE EXISTING GRAB

BAR

REMOVE EXISTING

LAVATORY

REMOVE EXISTING

MIRROR

REMOVE EXISTING

TOILET

EXISTING FINNED TUBE

COVER TO REMAIN

4' -8

SAW CUT AND REMOVE

APPROX. 4'-8"" WIDE

SECTION OF EXISTING

CMU WALL TO FIRST

JOINT ABOVE DESK

B

1/

2" 2'

-6

1'-

1'-

1/ 2"

3' -9

1'-

2' -6

A

BARRIER FREE

TURNING RADIUS

EXISTING SLIDING DOOR TO REMAIN

C

CORE DRILL 4" DEEP HOLE

IN EXISTING WALL FOR

NEW TOILET PAPER

HOLDERS. VERIFY DIAMETER

WITH APPROVED SHOP

DRAWINGS.

EXISTING

PLUMBING

OPENING

TO REMAIN

FURNISHINGS

1 NEW STAINLESS STEEL DESK

2 NEW COMBY ADA SINK AND TOILET

3 NEW 1-1/2" DIA. GRAB BAR

4 RELOCATED 12" X 12" X 6' LOCKER

5 EXISTING 2'-6" X 7'-6" METAL BED

6 NEW 18"X36" POLISHED STAINLESS STEEL

MIRROR

CELL ELEVATION A

3/4"=1'-0"

CELL ELEVATION B

3/4"=1'-0"

TYPICAL CELL PLAN

1/2"=1'-0"

NOTE: EXISTING TOILETS, SINKS, GRAB BARS AND MIRRORS ARE TO BE TURNED OVER TO THE FACILITY.

DESK PLAN

DESK FRONT

DESK ISOMETRIC

DESK SIDE

ROOM FINISH SCHEDULE:

CELLS:

FLOOR: NO WORK

WALLS: PAINT OR REPAINT

BASE: PAINT OR REPAINT

CEILING: PAINT OR REPAINT

SHOWER ROOMS:

FLOOR: RESINOUS FLOOR COATING

BASE: PAINT OR REPAINT

SHOWER WALLS: EPOXY WALL COATINGS

WALLS: PAINT OR REPAINT

CEILING: PAINT OR REPAINT

RAMP:

FLOOR: RESINOUS FLOOR COATING

BASE/WALL AT RAMP: RESINOUS COATING

WALL: PAINT OR REPAINT

BASE AT MASONRY: PAINT OR REPAINT

CEILING: NO WORK

NOTE: PATCH EXISTING VCT AT FLOORS.

P e t t i t t Y a s t e

S t r a u b

200S

LAWSON,C MICHIGAN

UITE

48017-1311

F A X248-658-7781 248-658-7777 P H O N E

C850 NORTH ROOKS ROAD

PL

UR

IB

U

E S

U N U

M

C I

R C

U M

S P

I C

E

S I

Q U

E R

E I S

P E

N I

N S

U L

A M

A M

OE

N

A M

D

EP

A R

TM

EN

T O

F

TE

C H

N O

LO

G

Y , M

A N

A G

EM

EN

T A

N D

B U

D G

ET

ST

A

TE

O

F M

IC

H

IG

A

N

A D

A M

P . L

A C

H , R

A , D

IR

EC

TO

R

ST

A

TE

F

A C

IL

IT

IE

S

A D

M

IN

IS

TR

A

TI

O N

D

ES

IG

N

A N

D C

O N

ST

R

U C

TI

O

N D

IV

IS

IO

N

A2

ADDENDUM No.1 6/4/2026

RELEASED FOR BIDS 5/15/2026

100% OWNER REVIEW 5/14/2026

90% OWNER REVIEW 3/30/2026

RELEASED FOR REBID 12/9/2022

RELEASED FOR BIDS 9/1/2022

CELL PLAN AND DETAILS

FILE NO: 472/19527. SMD

ACCT NO: 472 IBC MAINTPROJ

1727 BLUEWATER HWY

IONA, MI 48846

BELLAMY CREEK

CORRECTIONAL FACILITY

HOUSING UNIT 2

ADA RAMPS AND

IMPROVEMENT

A1

DESK AND STOOL ELEVATION C

3/4"=1'-0"

TYPICAL DEMO. TYPICAL NEW WORK.

NOTE: TYPICAL DEMOLITION AND NEW WORK TO OCCUR IN CELLS NOTED ON SHEET A1.

5'-0"

2' -1

2"

3'-0"

2' -0

12"X 48" STEEL ACCESS PANEL

BUILT INTO STAINLESS STEEL FILLER PANEL

ROLL IN TYPE ADA SHOWERADA TRANSFER

SHOWER UNIT

CYLINDER OPERATED

CAM LOCK

STAINLESS STEEL FILLER PANEL

BETWEEN SHOWER UNITS

2" MUD BED

SLOPED IN WALK

AREA

18X33 "L" GRAB

BAR

FOLDING SHOWER

SEAT

REUSE OWNER FURNISHED

SHOWER HEADS

48" GRAB BAR

30" GRAB BAR EACH END

A3

2' -0

5'

-0

3' -0

'-0

A5

REINSTALL EXISTING METAL GATE AND PANEL

EXISTING DRINKING

FOUNTAIN TO REMAIN

5' -4

'-2

REMOVE AND REPLACE EXISTING CEILING MOUNTED LIGHT FIXTURES.

NEW SLOPED MUD BED ON CONCRETE SLAB/

SLOPE TO TRENCH DRAINS

NOTE: PREPARE AND PATCH EXISTING PLASTER CEILING OR DRYWALL CEILING.

A5

A5

3'-0"

NEW 4" x 8" x 16" CMU

WITH WATER PROOFING

3'-0"

REMOVE EXISTING TILES WITHIN OUTLINE AND INSTALL

EPOXY FLOORING

INSTALL

NEW STAINLESS

STEEL GATE

INSTALL

NEW STAINLESS

STEEL GATE

EXISTING METAL

GATE

3' -0

A5

A5

A5

EXISTING DRINKING

FOUNTAIN TO REMAIN

REMOVE AND PROTECT EXISTING

METAL GATE AND PANEL

EXISTING CEILING

ACCESS DOOR TO

REMAIN

REMOVE EXISTING PLASTER CEILING

THIS AREA

3'-0"

ROLL IN TYPE

ADA SHOWER UNIT

MUD BED

TRENCH DRAIN

1'-0"

4"

2"

EXISTING DOUBLE 5/8"

GYPSUM BOARD CEILING

REPLACE/ PATCH AS

NEEDED

NEW LIGHT FIXTURE

MAX. 14" PER FOOT

SLOPE TO DRAIN

WATER PROOFING ON

NEW4" x 8" x 16" CMU

7'-

REUSE OWNER

FURNISHED

SHOWER HEADS

REUSE OWNER

FURNISHED

SHOWER CONTROLS

4"

4"

3"

4"

4"4"

SLOPED MUD BED

MAX. 14" PER FOOT

RESINOUS

FLOORING

STONHARD OVERLAYMENT

SPRAY ON TYPE WATER PROOFING AND

HIGH-PERFORMANCE EPOXY COATING

ON CMU WALL

POLYETHYLENE

BACKER

ROD

STONESET

GROUT (PITCHED

TO ADA

COMPLIANCE)

4"21

2"

15 8"

A5

ACCESS DOOR

SHOWER ROOM- NEW WORK

SCALE: 1/2"= 1'-0"

SHOWER ROOM- DEMOLITION

SCALE: 1/2"= 1'-0"

P e t t i t t Y a s t e

S t r a u b

200S

LAWSON,C MICHIGAN

UITE

48017-1311

F A X248-658-7781 248-658-7777 P H O N E

C850 NORTH ROOKS ROAD

PL

UR

IB

U

E S

U N

U M

C I

R C

U M

S P

I C

E

S I

Q U

E R

E I S

P E

N I

N S

U L

A M

A M

OE

N

A M

D

EP

A R

TM

EN

T O

F

TE

C H

N O

LO

G

Y , M

A N

A G

EM

EN

T A

N D

B U

D G

ET

ST

A

TE

O F

M

IC

H

IG

A N

A D

A M

P . L

A C

H , R

A , D

IR

EC

TO

R

ST

A

TE

F

A C

IL

IT

IE

S

A D

M

IN

IS

TR

A

TI

O N

D

ES

IG

N

A N

D C

O N

ST

R

U C

TI

O

N D

IV

IS

IO

N

A5

ADDENDUM No.1 6/3/2026

RELEASED FOR BIDS 5/15/2026

100% OWNER REVIEW 5/14/2026

90% OWNER REVIEW 3/30/2026

RELEASED FOR REBID 12/9/2022

RELEASED FOR BIDS 9/1/2022

SHOWER PLAN AND DETAILS

FILE NO: 472/19527. SMD

ACCT NO: 472 IBC MAINTPROJ

1727 BLUEWATER HWY

IONA, MI 48846

BELLAMY CREEK

CORRECTIONAL FACILITY

HOUSING UNIT 2

ADA RAMPS AND

IMPROVEMENT

A5

A5

SHOWER ROOM SECTION

3/8"=1'-0"A5

2 SHOWER ROOM ELEVATION

3/8"=1'-0"A5

3 RAMP ELEVATION

3/8"=1'-0"A5

1. NEW 60"X36" ROLL-IN SHOWER UNIT

2. NEW 36"X36" TRANSFER SHOWER UNIT

3. NEW TRENCH DRAIN - SEE SECTION DETAIL 8/A5

SHOWER ROOM SCHEDULE

TRENCH DRAIN DETAIL

1 1/2" = 1'-0"

NEW LIGHT FIXTURE MODEL DETAIL:

1. COOPER LIGHTING MODEL: FVS8- 4 - LD4 - 2 - STD - 40 - VNV - P187 - EDC1 - WL

2. KURTZON LIGHTING MODEL: VL-S - 1 - 1X4 - 2 - LEDH - 840 - UNV - 3 - SW

EXISTING FINNED TUBE RADIATION AND COVER TO

REMAIN

PROTECTED DURING CONSTRUCTION, REPAIR/

REPLACE IF DAMAGED

BY CONSTRUCTION ACTIVITY REMOVE EXISTING CONC.

MASONRY WALLS

REMOVE EXISTING FLUORESCENT SURFACE MOUNT

LIGHT FIXTURE

6" CONC. FLOOR

SLAB

STAINLESS

STEEL PANEL

NOTE: TURN OVER EXISTING SHOWER DOORS TO THE

FACILITY. REMOVE AND REINSTALL EXISTING SHOWER

CONTROLS AND HEADS INT0 NEW SHOWERS. FACILITY

WILL PROVIDE FORTH CONTROL AND SHOWER HEAD.

SHOWER DRAIN SECTION

3/8"=1'-0"A5

STAINLESS STEEL GATE JAMB

1 1/2" = 1'-0"

A5

A5

STAINLESS STEEL GATE

1 1/2" = 1'-0"A5

STAINLESS STEEL GATE

W/2"x2" SQUARE MESH

FASTEN TO CMU

Sheets and Views
HU2 Plans - 2026-A3 RAMP
HU2 Plans - 2026-A5 SHOWER ROOM
HU2 Plans - 2026-A4 RAMP DETAILS
HU2 Plans - 2026-A2 CELLS
HU2 Plans - 2026-C3 SITE DETAILS
HU2 Plans - 2026-C1 SITE DEMO
HU2 Plans - 2026-C2 SITE
HU2 Plans - 2026-A1 FLOOR PLAN
HU2 Plans - 2026-P1 Demo
HU2 Plans - 2026-P2 New Work
A5.pdf
Sheets and Views
A5 SHOWER ROOM
A1.pdf
Sheets and Views
A1 FLOOR PLAN
A2.pdf
Sheets and Views
A2 CELLS
A5.pdf
Sheets and Views
A5 SHOWER ROOM
A5.pdf
Sheets and Views
A5 SHOWER ROOM