466535 SDARNG AASF - Addendum 1 Drawings_2026-04-16.pdf
PDF 33 MB Posted
- Solicitation number
- 26IFB19796
- Issued by
- Pennington County, South Dakota
About this file
SDARNG AASF - Addendum 1 Drawings Summary
This document set comprises architectural, structural, mechanical, plumbing, and fire suppression construction drawings for the South Dakota Department of the Military's Rapid City Army Aviation Support Facility (AASF) Building 3 renovation project (CFMO# 466535). The project involves comprehensive interior renovation of approximately 20,000 square feet of office spaces, bathrooms, locker rooms, classrooms, hallways, vestibules, and related areas within the main hangar structure. Work is divided into two distinct phases to maintain continuous building occupancy. The scope includes concrete floor removal and replacement, underground plumbing relocation, structural damage correction, installation of two rooftop air handling units (rated at 1,850 CFM and 2,050 CFM), fire suppression system modifications with wet pipe sprinkler protection, electrical upgrades including new 225-amp panelboards and LED lighting with occupancy sensors, comprehensive plumbing installations, ADA accessibility compliance upgrades, and modern finish installation throughout the facility. The project requires substantial completion within 426 consecutive calendar days from the Notice to Proceed, with an anticipated completion date of August 1, 2027. An optional pre-bid conference is scheduled for April 24, 2026 at 8:00 AM MT at the facility's east entrance, and bids are due May 7, 2026 at 12:00 PM MT.
The project must comply with the 2021 International Building Code, NFPA 13 sprinkler design standards, and the Build America Buy America Act requiring all iron, steel, manufactured products, and construction materials to be produced in the United States. Bids exceeding $100,000 require either a 5% certified check or 10% bid bond. Successful bidders must provide Performance and Payment Bonds and maintain Commercial General Liability insurance of $1,000,000 minimum and Builder's Risk Insurance for the full contract value. Liquidated damages are assessed at $1,150.00 per calendar day for delays in achieving substantial completion and $575.00 per calendar day for delays beyond substantial completion. Stone Group Architects (600 East 7th Street, Sioux Falls, SD 57103; phone 605-271-1144) serves as the architect/engineer and issuing office, with consulting structural engineer Michael Albertson from Albertson Engineering. Project Manager Kyle Roe handles inquiries at (605) 381-4093 or kyle.roe@state.sd.us. No specific contract award value or budget has been disclosed in the available materials.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SYMBOLS LEGEND
RIGID INSULATION
WOOD ROUGH (CONTINUOUS)
WOOD ROUGH (SPACED)
EARTH
CONCRETE
BLOCK WALL/VENEER
GYPSUM BOARD
PLYWOOD
BATT INSULATION
NEW CONSTRUCTION
EXISTING CONSTRUCTION TO
BE REMOVED
DIMENSION LINE
BREAK LINE
DETAIL INDICATOR
X
X-XX
DETAIL INDICATOR
X
X-XX
X
WALL SECTION
INDICATOR
X
X-XX
X
X-XX
ELEVATION
INDICATOR, EXTERIOR
ELEVATION INDICATOR
CENTER LINE
ELEVATION INDICATOR,
INTERIOR,X-XX
X
X-XX
X
X
X
X
NORTH ARROW
CG
CORNER GUARD
FEC FIRE EXTINGUISHER CABINET
XX KEYNOTE
A GRID LINES
XXX
ROOM
ROOM NAME AND NUMBER
XX
FURNITURE, FIXTURE OR EQUIPMENT,
AND FINISHES INDICATOR
XXX
DOOR OPENING/BORROWED
LIGHT IDENTIFIER
XX DRAWING BLOCK
TITLE, TYPICAL
DRAWING TITLE
XX=XX
XX INTERIOR PARTITION TYPES
NORTH
X
X-XX
BUILDING SECTION
INDICATOR
X
X-XX
DETAIL INDICATOR
X-XX
VICINITY MAP
Address:
Office Phone:
Project Manager:
E-mail:
Michael Albertson mike@albertsonengineering.com
ENGINEER Michael Albertson
600 E. 7th Street Sioux Falls, SD 57103
Address:
605.271.1144Office Phone:
Project Manager:
E-mail:
ARCHITECT Todd Stone
GarryB@stonegrouparch.com
Garry Black
4/
/2
4:
:0
P
M
SDARNG AASF
Permit / Bid Set
04.26.2024
RAPID CITY REGIONAL AIRPORT
AVIATION SUPPORT FACILITY
SHEET INDEX
01 - GENERAL
G-000 COVER SHEET
G-001 ACCESSIBILITY DETAILS
G-002 ACCESSIBILITY DETAILS
G-003 LIFE SAFETY CODE REVIEW
G-004 LIFE SAFETY PLAN - NEW WALL RATINGS
G-005 LIFE SAFETY PLAN - EXISTING WALL RATINGS
03 - STRUCTURAL
S-001 STRUCTURAL GENERAL NOTES
S-002 IBC INSPECTION TABLES
S-003 IBC INSPECTION TABLES CONT.
S-101 PARTIAL FOUNDATION PLAN
S-102 PARTIAL FRAMING PLAN
S-501 DETAILS
S-601 STANDARD DETAILS / SCHEDULES
S-602 STANDARD DETAILS / SCHEDULES
05 - ARCHITECTURAL DEMOLITION
SD-101 FLOOR PLAN-AREA A
SD-102 FLOOR PLAN-AREA B
SD-103 FLOOR PLAN-AREA C
AD-001 EXIST / DEMO PLAN-OVERALL - PHASE PLAN
AD-101 EXIST / DEMO PLAN-OVERALL
AD-110 EXIST / DEMO PLAN-AREA A
AD-111 EXIST / DEMO PLAN-AREA B
AD-112 EXIST / DEMO PLAN-AREA C
AD-120 EXIST / DEMO REFLECTED CEILING PLAN-OVERALL
06 - ARCHITECTURAL
A-001 FLOOR PLAN-OVERALL- PHASE PLAN
A-101 FLOOR PLAN-OVERALL
A-102 FLOOR PLAN-AREA A
A-103 FLOOR PLAN-AREA B
A-104 FLOOR PLAN-AREA C
ABBREVIATIONS
SYMBOLS
# POUND OR NUMBER
& AND
< ANGLE
<< DOUBLE ANGLE
@ AT
d PENNEY
Ø ROUND OR DIAMETER
A
A/E ARCHITECT/ENGINEER
AB ANCHOR BOLT
ABV ABOVE
AC ASPHALTIC CONCRETE/AIR CONDITIONER
ACC ACCESSIBLE
ACM ALUMINUM COMPOSITE MATERIAL
ACOUS ACOUSTICAL
ACT ACOUSTICAL CEILING TILE
AD AREA DRAIN
ADA AMERICANS WITH DISABILITIES ACT
ADD ADDENDUM
ADH ADHESIVE
ADJ ADJUSTABLE, ADJACENT, ADJOINING
AFF ABOVE FINISHED FLOOR
AFG ABOVE FINISHED GRADE
AHJ AUTHORITY HAVING JURISDICTION
ALT ALTERNATIVE
ALUM ALUMINUM
ANSI AMERICAN NATIONAL STANDARDS INSTITUTE
APC ACOUSTICAL PANEL CEILING
APPROX APPROXIMATE
ARCH ARCHITECT (URAL)
ASI ARCHITECT'S SUPPLEMENTAL INSTRUCTIONS
B
BD BOARD
BEV BEVELED
BFF BELOW FINISH FLOOR
BL BRICK LEDGE
BLDG BUILDING
BLKG BLOCK (ING)
BM BEAM
BO BOTTOM OF
BOC BOTTOM OF CONCRETE
BOF BOTTOM OF FOOTING
BOT BOTTOM
BRG BEARING
BRK BRICK
BRKT BRACKET
BSMT BASEMENT
BTWN BETWEEN
BUR BUILT UP ROOFING
C
C CHANNEL/CELSIUS
CAB CABINET
CB CERAMIC BASE
CCW COUNTER CLOCKWISE
CD CONSTRUCTION DOCUMENTS
SHEET INDEX
A-105 ENLARGED FLOOR PLAN-RESTROOMS
A-106 FLOOR PLAN-OVERALL - ALTERNATES
A-107 ADD ALTERNATES
A-108 ADD ALTERNATES
A-110 REFLECTED CEILING PLAN-OVERALL
A-111 REFLECTED CEILING PLAN-AREA A
A-112 REFLECTED CEILING PLAN-AREA B
A-113 REFLECTED CEILING PLAN-AREA C
A-450A INTERIOR ELEVATIONS-AREA A
A-450B INTERIOR ELEVATIONS-AREA A
A-450C INTERIOR ELEVATIONS-AREA A
A-451A INTERIOR ELEVATIONS-AREA B
A-451B INTERIOR ELEVATIONS-AREA B
A-452 INTERIOR ELEVATIONS-AREA C
A-453 CASEWORK-FLIGHT OPS
A-454 CASEWORK-FLIGHT OPS & CORR. 158
A-501 SECTIONS / DETAILS
A-601 SCHEDULES
A-602 SIGNAGE PLAN & SCHEDULE
A-801 FINISH SCHEDULES
A-802 FINISH PLAN
08 - FIRE PROTECTION
FG101 FIRE PROTECTION SYMBOLS LEGEND AND GENERAL
NOTES
FD101 FIRE SUPPRESSION DEMOLITION PLAN-OVERALL
FD103 1ST LEVEL FIRE SUPPRESSION DEMOLITION
PLAN-ALSE MAINTENANCE SUPPORT-AREA B
FX101 1ST LEVEL FIRE SUPPRESSION PLAN-OVERALL
FX102 1ST LEVEL FIRE SUPPRESSION PLAN-ADMIN
TRAINING-AREA A
FX103 1ST LEVEL FIRE SUPPRESSION PLAN-ALSE
MAINTENANCE SUPPORT-AREA B
FX104 1ST LEVEL FIRE SUPPRESSION PLAN-FLIGHT
OPERATIONS-AREA C
F-401 FIRE SUPPRESSION LARGE-SCALE DEMOLITION PLANS
F-402 FIRE SUPPRESSION LARGE-SCALE PLANS
F-403 FIRE SUPPRESSION ISOMETRICS
09 - PLUMBING
PD001 PLUMBING FOUNDATION DEMOLITION PLAN
PD101 1ST LEVEL PLUMBING DEMOLITION PLAN-OVERALL
PL001 OVERALL FOUNDATION PLUMBING PLAN
PL002 FOUNDATION PLUMBING PLAN-ADMIN TRAINING-AREA
A
PL003 FOUNDATION PLUMBING PLAN-ALSE MAINTENANCE
SUPPORT-AREA B
PL004 FOUNDATION PLUMBING PLAN-FLIGHT
OPERATIONS-AREA C
PL101 OVERALL 1ST LEVEL PLUMBING PLAN
PL102 1ST LEVEL PLUMBING PLAN-ADMING TRAINING-AREA-A
PL103 1ST LEVEL PLUMBING PLAN-ALSE MAINTENANCE
SUPPORT-AREA B
PL104 1ST LEVEL PLUMBING PLAN-FLIGHT
OPERATIONS-AREA C
P-201 PLUMBING RISERS
P-301 PLUMBING FIXTURES
P-501 PLUMBING DETAILS & SCHEDULES
10 - MECHANICAL
SHEET INDEX
MG101 MECHANICAL SYMBOLS LEGEND AND GENERAL
NOTES
MD101 1ST LEVEL HVAC DEMOLITION PLAN-OVERALL
MD102 1ST LEVEL HVAC DEMOLITION PLAN-ADMIN
TRAINING-AREA A
MD103 1ST LEVEL HVAC DEMOLITION PLAN-ALSE
MAINTENANCE SUPPORT-AREA B
MD104 1ST LEVEL HVAC DEMOLITION PLAN-FLIGHT
OPERATIONS-AREA C
MD105 1ST LEVEL MECHANICAL PIPING DEMOLITION
PLAN-OVERALL
MD106 1ST LEVEL MECHANICAL PIPING DEMOLITION
PLAN-ADMIN TRAINING-AREA A
MD107 1ST LEVEL MECHANICAL PIPING DEMOLITION
PLAN-ALSE MAINTENANCE SUPPORT-AREA B
MD108 1ST LEVEL MECHANICAL PIPING DEMOLITION
PLAN-FLIGHT OPERATION-AREA C
MD109 ROOF MECHANICAL DEMOLITION PLAN-OVERALL
MH101 1ST LEVEL HVAC PLAN-OVERALL
MH102 1ST LEVEL HVAC PLAN-ADMIN TRAINING-AREA A
MH103 1ST LEVEL HVAC PLAN-ALSE MAINTENANCE
SUPPORT-AREA B
MH104 1ST LEVEL HVAC PLAN-FLIGHT OPERATIONS-AREA C
MH105 ROOF MECHANICAL PLAN-OVERALL
MP101 1ST LEVEL MECHANICAL PIPING PLAN-OVERALL
MP102 1ST LEVEL MECHANICAL PIPING PLAN-ADMIN
TRAINING-AREA A
MP103 1ST LEVEL MECHANICAL PIPING PLAN-ALSE
MAINTENANCE SUPPORT-AREA B
MP104 1ST LEVEL MECHANICAL PIPING PLAN-FLIGHT
OPERATION-AREA C
M-501 MECHANICAL DETAILS
M-701 MECHANICAL SCHECULES
11 - ELECTRICAL
EG101 ELECTRICAL SYMBOLS LEGEND AND GENERAL NOTES
ED101 OVERALL 1ST LEVEL ELECTRICAL DEMOLITION PLAN
ED102 1ST LEVEL ELECTRICAL DEMOLITION PLAN-ADMIN
TRAINING-AREA A
ED103 1ST LEVEL ELECTRICAL DEMOLITION PLAN-ALSE
MAINTENANCE SUPPORT-AREA B
ED104 1ST LEVEL ELECTRICAL DEMOLITION PLAN-FLIGHT
OPERATION-AREA C
EL101 1ST LEVEL LIGHTING PLAN-OVERALL
EL102 1ST LEVEL LIGHTING PLAN-ADMIN TRAINING-AREA A
EL103 1ST LEVEL LIGHTING PLAN-ALSE MAINTENANCE
SUPPORT-AREA B
EL104 1ST LEVEL LIGHTING PLAN-FLIGHT OPERATIONS-AREA
C
EP101 1ST LEVEL POWER PLAN-OVERALL
EP102 1ST LEVEL POWER PLAN-ADMIN TRAINING-AREA A
EP103 1ST LEVEL POWER PLAN-ALSE MAINTENANCE
SUPPOERT-AREA B
EP104 1ST LEVEL POWER PLAN-FLIGHT OPERATIONS-AREA C
EY101 OVERALL 1ST LEVEL SPECIAL SYSTEMS PLAN
EY102 1ST LEVEL SPECIAL SYSTEM PLAN-ADMIN
TRAINING-AREA A
EY103 1ST LEVEL SPECIAL SYSTEM PLAN-ALSE
MAINTENANCE SUPPORT-AREA B
EY104 1ST LEVEL SPECIAL SYSTEM PLAN-FLIGHT
OPERATIONS-AREA C
E-501 ELECTRICAL DETAILS
E-701 ELECTRICAL SCHEDULES
TOTAL SHEET COUNT: 112
ABBREVIATIONS
CEM CEMENT
CF CUBIC FEET OR FOOT
CG CORNER GUARD
CH CHANNEL
CIPC CAST-IN-PLACE CONCRETE
CJ CONTROL/CONSTRUCTION JOINT
CL CENTER LINE
CLKG CAULKING
CLO CLEAR, CLEARANCE
CMU CONCRETE MASONRY UNIT
CO CHANGE ORDER/CLEANOUT
COL COLUMN
COMB COMBINATION
COMP COMPOSITE/COMPOSITION
CONC CONCRETE
CONN CONNECT (ION)
CONST CONSTRUCTION
CONT CONTINUOUS, CONTINUE
CONTR CONTRACT (OR)
COORD COORDINATE
CORR CORRUGATED/CORRIDOR
CPPT CARPET TILE
CPT CARPET
CSMT CASEMENT
CT CERAMIC TILE
CTB CARPET TILE BASE
CTR CENTER
D
D DEPTH
DBL DOUBLE
DEMO DEMOLITION, DEMOLISH
DEPT DEPARTMENT
DET DETAIL
DF DRINKING FOUNTAIN
DIA DIAMETER
DIAG DIAGONAL
DIM DIMENSION
DISP DISPENSER
DN DOWN
DR DOOR
DS DOWNSPOUT
DW DISHWASHER
DWG DRAWING (S)
DWR DRAWER
DWTR DUMBWAITER
E
(E) EXISTING
E EAST
EA EACH
EF EACH FACE
EJ EXPANSION JOINT
EL ELEVATION
ELEC ELECTRICAL
ELVE ELEVATOR
EMER EMERGENCY
ENGR ENGINEER
ENL ENLARGED
ABBREVIATIONS
EOP EDGE OF PAVEMENT
EPDM ETHYLENE PROPYLENE DIENE TERPOLYMER
MEMBRANE
EPS EXPANDED POLYSTYRENE BOARD
EPT EPOXY PAINT
EQ EQUAL
EQUIP EQUIPMENT
ES EACH SIDE
EST ESTIMATE
ETC ETCETERA
ETR EXISTING TO REMAIN
EW EACH WAY
EWC ELECTRIC WATER COOLER
EXC EXCAVATE/EXCAVATION
EXH EXHAUST
EXIST EXISTING
EXP EXPANSION/EXPOSED
EXT EXTERIOR
F
FA FIRE ALARM
FAB FABRICATE/FABRICATION
FD FLOOR DRAIN
FDC FIRE DEPARTMENT CONNECTION
FDTN FOUNDATION
FE FIRE EXTINGUISHER
FEC FIRE EXTINGUISHER CABINET
FF FINISHED FLOOR
FFE FINISHED FLOOR ELEVATION
FIN FINISH (ED)
FLR FLOOR (ING)
FLUOR FLUORESCENT
FO FACE OF
FOC FACE OF CONCRETE
FOF FACE OF FINISH
FOM FACE OF MASONRY
FOS FACE OF STUD
FR FIRE RESISTANT/FRAME
FRP FIBERGLASS REINFORCED PANEL
FS FLOOR SINK
FT FOOR, FEET/FIRE TREATED
FTG FOOTING
FURN FURNISH
FUT FUTURE
G
GA GAGE, GAUGE
GALV GALVANIZED
GB GRAB BAR
GC GENERAL CONTRACTOR
GI GALVANIZED IRON
GL GLASS
GLU LAM GLUE LAMINATED (BEAM)
GWB GYPSUM WALL BOARD
GYP BD GYPSUM
H
HB HOSE BIB
HC HANDICAP / HOLLOW CORE
ABBREVIATIONS
HD HEAVY DUTY
HDBD HARDBOARD
HDR HEADER
HM HOLLOW METAL
HORZ HORIZONTAL
HR HOUR
HT HEIGHT
HVAC HEATING, VENTILATION, AIRCONDITIONING
I
IBC INTERNATIONAL BUILDING CODE
ICC INTERNATIONAL CODE COUNCIL
ID INSIDE DIAMETER/DIMENSION
IFC INTERNATIONAL FIRE CODE
IN INCH (ES)
INCL INCLUDE (D), INCLUDING
INFO INFORMATION
INSP INSPECTION
INSTR INSTRUCTION (S)
INSUL INSULATE (D), INSULATION
INT INTERIOR
J
JAN JANITOR
JST JOIST
JT JOINT
K
KCJ KEYED CONSTRUCTION JOINT
KO KNOCK OUT
L
L LENGHT / ANGLE
LAB LABORATORY
LAM LAMINATE (D)
LAV LAVATORY
LB POUND
LF LINEAR FEET
LH LEFT HAND
LKR LOCKER
LOC LOCATION
LONG LONGITUDINAL
LT LIGHT
LVR LOUVER
LVT LUXURY VINYL TILE
M
MAS MASONRY
MATL MATERIAL
MAX MAXIMUM
MC MEDICINE CABINET
MECH MECHANICAL
MEMB MEMBRANE
MEZZ MEZZANINE
MFR MANUFACTURE (R)
MIN MINIMUM
MISC MISCELLANEOUS
MNTG MOUNTING
MO MASONRY OPENING
ABBREVIATIONS
MR MIRROR
MTL METAL
N
(N) NEW
N NORTH
NA NOT APPLICABLE
NIC NOT IN CONTRACT
NO NUMBER
NOM NOMINAL
NTS NOT TO SCALE
O
OC ON CENTER
OD OUTSIDE DIAMETER
OFCI OWNER FURNISHED / CONTRACTOR
INSTALLED
OFOI OWNER FURNISHED / OWNER INSTALLED
OH OVERHEAD
OPG OPENING
OPP OPPOSITE
ORD OVERFLOW ROOF DRAIN
ORIG ORIGINAL
OZ OUNCE
P
PAR PARALLEL
PCF POUNDS PER CUBIC FOOT
PED PEDISTAL
PERF PERFORATED
PERP PERPENDICULAR
PL PLATE
PLAM PLASTIC LAMINATE
PLMG PLUMBING
PLYWD PLYWOOD
PNL PANEL
PR PAIR / PROPOSAL REQUEST
PRCST PRECAST
PREFAB PREFABRICATE
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
PT PAINT / PRESSURE TREATED
PTD PAPER TOWEL DISPENSER
PTN PARTITION
PTR PAPER TOWEL RECEPTICAL
PVC POLYVINYL CHOLORIDE
Q
QT QUARRY TILE
R
R RADIUS / RISER
RB RUBBER BASE
RBR RUBBER
RCP REFLECTED CEILING PLAN
RD ROOF DRAIN
REBAR REINFORCING BAR
REC RECESSED
REF REFERENCE / REFRIGERATOR
ABBREVIATIONS
REINF REINFORC (D), (ING), (MENT)
REQ REQUIRE
REQD REQUIRED
RES RESILIENT FLOORING
RET RETURN
REV REVISION (S), REVISED
RFG ROOFING
RFI REQUEST FOR INFORMATION
RFP REQUEST FOR PROPOSAL
RH RIGHT HAND
RL RIDGE LINE
RM ROOM
RO ROUGH OPENING
ROW RIGHT OF WAY
RVS REVERSE (SIDE)
RWL RAIN WATER LEADER
S
S SOUTH
SB SPLASH BACK
SC SOLID CORE
SCHED SCHEDULE
SCR SHOWER CURTAIN ROD
SCT SECTION
SD SOAP DISPENSER
SF SQUARE FOOT
SHT SHEET
SHTHG SHEATHING
SIM SIMILAR
SLDG SLIDING
SLNT SEALANT
SND SANITARY NAPKIN DISPENSER
SNX SANIARY NAPKIN DISPOSAL
SOG SLAB ON GRADE
SPEC SPECIFICATION (S)
SQ SQUARE
SSM SOLID SURFACE MATERIAL
SST STAINLESS STEEL
ST STREET
STC SOUND TRANSMISSION CLASS
STD STANDARD
STL STEEL
STOR STORAGE
STRUCT STRUCTURAL
SUSP SUSPENDED
SV SHEET VINYL
SW SHEARWALL
SYM SYMMETRICAL
T
T TREAD
T&B TOP & BOTTOM
T&G TOUNGE AND GROOVE
TB TOWEL BAR
TBD TO BE DETERMINED
TEMP TEMPORARY / TEMPERED
TER TERRAZZO
TFE TOP FOOTING ELEVATION
THD THREAD (ED) (S)
ABBREVIATIONS
THK THICKNESS
THRU THROUGH
TKBD TACKBOARD
TL TILE
TO TOP OF
TOB TOP OF BEAM
TOC TOP O F CONCRETE/CURB
TOD TOP OF DECK
TOF TOP OF FOOTING (FOUNDATION)
TOJ TOP OF JOIST
TOM TOP OF MASONRY
TOP TOP OF PIER
TOS TOP OF SLAB/STEEL
TOW TOP OF WALL
TPD TOILET PAPER DISPENSER
TPO THERMOPLASTIC POLYOLEFIN
TPTN TOILET PARTITION
TRANS TRANSVERSE
TS TUBE STEEL
TYP TYPICAL
U
UG UNDERGROUND
UH UNIT HEATER
UNFIN UNFINISHED
UNO UNLESS NOTED OTHERWISE
UON UNLESS OTHERWISE NOTED
UTIL UTILITY
V
V SHEAR
VAR VARIES
VB VAPOR BARRIER
VCT VINYL COMPOSITION TILE
VERT VERTICAL
VEST VESTIBULE
VIF VERIFY IN FIELD
VR VAPOR RETARDER
VWC VINYL WALL COVERING
W
W WEST/WIDTH
W/ WITH
W//O WITHOUT
WA WEDGE ACHOR
WB WOOD BASE
WC WATER CLOSET
WD WOOD/WOODWORK
WDW WINDOW
WF (W) WIDE FLANGE
WG WALL GUARD
WH WATER HEATER
WI WROUGHT IRON
WL WIND LOAD
WP WATERPROOF (ING)
WR WATER RESISTANT
WSCT WAINSCOT
WT WEIGHT / WINDOW TREATMENT
WWF WELDED WIRE FABRIC
PROJECT LOCATION
MEP ENGINEER
Address:
Office phone:
Mechanical Engineer:
Email:
Electrical Engineer:
Email:
12700 West Dodge Road Omaha, NE 69154
402-330-5900
Joseph D. Bannwarth jbannwarth@farris-usa.com
Robert J. Hotovy rhotovy@farris-usa.com
SD-44
NO. ISSUE LOG DATE
1 Permit / Bid Set 04-26-2024
2 Addendum 1 04-16-2026
Figure 302.2 Carpet Pile Height
Figure 303.2 Vertical Change in Level
1/ 2" m ax
1/ 4" m ax
Figure 302.3 Elongated Openings in Floor or
Ground Surfaces d ir ec ti o n o f tr av el lo n g d im d o m in an t p er p in d ic u la r to
1/2" max dominant direction of travel
Figure 303.3 Beveled Change in Level
1/
1/
1/
1/
Figure 304.3.1.2 Circular Turning Space - Existing
Buildings Size and Overlap
Figure 304.3.1.1 Circular Turning Space - New Buildings Size and Overlap m ax
Overlap of knee and toe clearance Overlap of knee and toe clearance
6.
2.
m ax
P er ø 5'-7" min ø 5'-0" min
Figure 304.3.2.2 T-Shaped Turning Space New Buildings - Size and Overlap ar m ar m base
Figure 304.3.2.1(A) T-Shaped Turning Space New Buildings - Option 1 ar m ar m base
68" min min
16" min
36" min
16" m in m in36 m in
Figure 304.3.2.1(B) T-Shaped Turning Space New Buildings - Option 2 ar m ar m base
64" min min
11" min
42" min
11" m in m in m in
Figure 304.3.2.1(C) T-Shaped Turning Space New Buildings - Option 3 ar m ar m base
64" min min
12" min
40" min
12" m in m in m in
60" min min
12" min
36" min
12" m in36 m in m in
Figure 305.3.2 Clear Floor or Ground
Space- Existing Buildings
Figure 305.5 Position of Clear Floor or Ground Space
Figure 305.7.1 Maneuvering Clearance in an
Alcove, Forward Approach
Figure 305.7.2 Maneuvering Clearance in an
Alcove, Parallel Approach
(a) forward
(b) parallel
Figure 305.3.1 Clear Floor or Ground Space- New Buildings
52" min m in
48" min m in
30" min m in
48" min m in
36" min
X
4"
60" min
X
5"
Figure 306.2 Toe Clearance
Figure 306.3 Knee Clearance
(b) plan
(a) elevation
9"
6" max m in
17"- 25"
(b) plan
(a) elevation m in
25" max
11" min
8" min m in
Figure 307.2 Limits of Protruding Objects
4" max
X
7"
X
0"
Figure 307.3 Post-Mounted Protruding Objects
(b)(a)
0"
12" max 12" max m ax X > 12"
X > 12" m in
Figure 307.4 Vertical Clearance
M ax
X
Figure 308.3.1 Unobstructed Side Reach
Figure 308.3.2 Unobstructed High Side Reach
Figure 308.2.2 Obstructed High Forward Reach
Figure 308.2.1 Unobstructed
Forward Reach
(a) (b)
(b)(a) m in m ax m ax
20" max m ax
20"- 25" max
10" max m in m ax
10" max 10" - 24" max m ax m ax m ax m ax
B U
IL
D
IN
G
B L
O C
K S
Figure 403.5.2 Clear Width at Turn Existing Buildings
Figure 403.5.1 Clear Width of an Accessible Route
(a) 180 degree turn
(b) 180 degree turn
(Exception)
Figure 403.5.2.1 Clear Width at Turn
(A) 180 degree turn
New Buildings - Option 1 m in
(B) 180 degree turn
New Buildings - Option 2 m in
(C) 180 degree turn
New Building - Option 3 m in
38" min m in
36" min m in
Figure 403.5.3.1 Clear Width At 90-Degree Turn
36" min m in
4" min 28" min
4" m in m in
Figure 403.5.3.2 Clear Width At 90-Degree Turn
Existing Buildings
36" min m in
Figure 403.5.3.1 Clear Width At 90-Degree Turn
Existing Buildings
36" min m in
36" min
X<52"
36" min 42" min
X<52"
42" min 43" min
X<52"
43" min m in m in
42" min
X<48"
42" min 36" min
X<48"
36" min
32" min
36" min
32" min
36" min m ax m in m ax
(a) 90 degree trun
New Building - Option 1
(b) 90 degree trun
New Building - Option 2
(c) 90 degree trun
New Building - Option 3
A C
C E
S S
IB
L
E R
O U
T E
S
Figure 405.7 Ramp Landings landing landingramp run ramp run landing ra m p ru n
(a) straight
(b) change in direction
60" Min 60" Min 60" Min
M in
Figure 405.9.1 Extended Floor or Ground Surface
Edge Protection
Figure 405.9.2 Curb or Barrier Edge Protection
Figure 406.2 Counter Slope of Surfaces Adjacent to Curb Ramps curb ramp slope adjoining surface maximum slope
Figure 406.3 Sides of Curb Ramps flared sides 1:10 max slope slope slope
Figure 406.2 (A) Perpendicular Curb Ramp
Where a pedestrian circulation path crosses, flared sides sloped 1:10
48" Min
M in
Curb of ramp flares painted if adjacent curb is painted (Section 406.5.6)
Building or sidewalk edge
Figure 406.2 (B) Perpendicular Curb Ramp
M in
48" Min Building or sidewalk edge
Planting area Planting area
Figure 406.3
(A) Parallel curb ramp
M in
48" Min Building or sidewalk edge
Figure 406.3
(B) Parallel curb ramp
Building or sidewalk edge
Planting area
M in
48" min
Figure 406.4 Landings at the Top of Curb Ramps
Figure 406.6 Diagonal or Corner Type Curb Ramps
Figure 406.7 Islands in Crossings
(a) cut through an island
(b) curb ramp at island
24" Min
24" Min
48" Min at least as wide as curb ramp
Figure 705.6 (A) Extent of Detectable Warning-
Perpendicular m in m in
Figure 705.6 (B) Extent of Detectable Warning-
Returnd Curb
Figure 705.6 (C) Extent of Detectable Warning-
Parallel m in
(section 403.5)
32" -36" min
M in at least as wide as curb ramp
M in
36" Min full width of the curb ramp full width of the curb ramp at least as wide as ramp run
12" Min 12" Min
X < 4"
C U
R B
S A
N D
R A
M P
S
SHEET TITLE:
CHECKED BY:
PROJECT NO.:
ISSUE DATE:
DESIGNED BY:
DRAWN BY:
SHEET NUMBER:
A
B
D
1 2 3 4
C
F ul l s iz e x3
6;
H al f s iz e x1
A
B
D
C
1 2 3 4 5
600 E. 7th Street Sioux Falls, SD 57103 phone: 605.271.1144 stonegrouparchitects.com
© Copyright 2024
4/
/2
1:
:0
P
M
G-001
221060
04.26.2024
JM, JH, JD
JH/JD
JM
A V
IA
T
IO
N
S U
P P
O R
T F
A C
IL
IT
Y S
D A
R N
G A
A S
F R
A P
ID
C
IT
Y
R E
G
IO
N A
L A
IR
P
O R
T
ACCESSIBILITY DETAILS
Permit / Bid Set
NO. ISSUE LOG DATE
1 Permit / Bid Set 04-26-2024
Figure 611.4 Height of Laundry
Compartment Opening
(a) top loading
(b) front loading m ax
Figure 604.2 Water Closet
Location
(a) wheelchair accessible water closets
(b) ambulatory accessible
Water closets
Figure 604.3.1 Size of Clearance at
Water Closets
Figure 604.3.2 (exception) Overlap of Water Closet Clearance in Residential
Dwelling Units
Figure 604.5.1 Side Wall Grab Bar at
Water Closets
Figure 604.5.2 Rear Wall Grab Bar at Water Closets
Figure 1104.11.1.1 Swing-up Grab Bar for Water Closet
Figure 604.7 Dispenser Outlet Location
Figure 604.8.1.2 Wheelchair Accessible Toilet
Compartment Doors
Figure 604.8.1.4 Wheelchair Accessible Toilet Compartment Toe Clearance
Figure 604.8.2 Ambulatory Accessible
Toilet Compartment
Transfer Side comply with section 609.3
(a) adult wall hung water closet
(b) adult floor mounted water closet and children's water closet
(b) elevation children
(a) elevation adult
(c) plan alternate door location
Figure 604.9.2.3 Wheelchair Toilet Compartments Alternate
Wheelchair Toilet Compartment m in
60" min
Figure 604.8.1.1 Size of Wheelchair Accessible Toilet Compartments m in
60" min m in
60" min 42 m in
4" max
4" m ax m in m in
35" - 37"
6" m in
6" min
6" min
9" m in m in6" min
Partition m in m ax7" - 9"
18" min 18" min
15 3/4" 15 3/4"36" min
24" min min
12" 12" max 42" min
54" min
42" m in
39" - 41" m in m in
60" min
18" min m in
60" min
16" - 18"
17" - 19"
P L
U M
B
IN
G E
L E
M E
N T
S A
N D
F A
C
IL
IT
IE
S
Figure 602.2.1 (A) Clear Floor Space at Wheelchair Drinking
Fountains
Figure 602.2.1 (B) Clear Floor Space at Wheelchair Drinking Fountains Primarly for
Children's use Exception
Children Adults
Figure 602.2.3 Wheelchair Drinking
Fountain Spout Height and Location
-4 m ax
-4 m ax
Figure 602.3.2 Standing use Drinking Fountain Spout Height and Location
Figure 602.3.3 Drinking Fountain
Spout Location m ax m ax
Children Adults
5" max (602.2.4)
15" min for Adults
D R
IN
K
IN
G
F O
U N
T A
IN
S
Figure 609.2.2 Grab Bar Non-Circular Cross Section
4" - 4.8" perimeter
2" m ax 2" max
(a) (b)
Figure 607.2 Clearance for Bathtubs
Figure 607.4.1 Grab Bars for Bathtubs with
Permanent Seats
Figure 607.4.2 Grab Bars for Bathtubs with Removable In-Tub Seats
Figure 607.5 Bathtub Control
Location
Figure 610.2 Bathtub Seats back wall head end wallcontrol end wall back wall head end wall control end wall
(b) plan back wall head end wall control end wall back wall head end wall control end wall
(a) removable in-tub seat
(b) permanent seat control end wall
(a) Removable In-Tub seat
(b) Permanent seat
(a) elevation
(b) plan
Length of Bathtub m in
Length of Bathtub 12" min m in
(a) elevation
8"
0"
15" max12" max m in
8"
0" m in
24" min
12" max 24" max m in
15" min15" - 16"
Figure 608.3.1 Grab Bars for Transfer-
Type Showers
Figure 608.3.2 Grab Bars for Standard Roll-In Type Showers
Figure 608.3.3 Grab Bars for Alternate Roll-In Type Showers seat wall control wall back wall back wall side wall side wall back wall back wall front wall side wall side wall side wall side wall
(b) with seat
Figure 608.2.1.2(B) Transfer-Type Shower Compartment Clearances
New Buildings- Option 2 seat wall control wall back wall
52" max m ax
4" max
Figure 608.2.1.2(C) Transfer-Type Shower Compartment Clearances
Existing Buildings- Option 2 seat wall control wall back wall m ax
48" max
18"
4" M ax
6" m ax
6" m ax
6" max 6" max
6" max6" max
6" m ax
Figure 608.5.1 Transfer-Type Shower Compartment Control
Location
Figure 608.5.2 Standard Roll-In Type Shower Compartment
Control Location
Figure 608.5.3 Alternate Roll-In Type Shower Compartment Control Location
Figure 609.3 Spacing of Grab Bars side wall back wall can be located on any wall of shower
(a) without seat
(b) with seat
(a) projecting objects
(b) recessed objects side wall back wall
(a) with seat
(elevation)
(b) with seat
(elevation)
(d) with seat
(plan)
(c) without seat
(plan) side wall side wall side wall side wall back wallback wall front wall front wall
15" max m in m ax m in m ax m ax
Figure 610.3 Extent of Seat
Figure 610.3.1 Rectangular Shower Seat
Figure 610.3.2 L-Shaped Shower Seat seat wall seat wall
(a) size
(b) distance from wall seat wall
(a) rectangular
(b) L-shaped compartment entry compartment entry
15" max m in
1/
2" m ax
3" m ax
3" m ax
(a) without seat
2 1/2" max
15" - 16"
1/
2" m ax
2 1/2" max15" - 16"
22" - 23"
1/
2" m ax m in m ax
27" max m in m ax m in
6" m ax
6" max
" T U
B S
A N
D S
H O
W E
R S
Figure 703.6.1 Pictogram Field
MEN not in pictogram field
6" M in
Figure 705.1 Size and Spacing of Truncated Domes base diameter of 0.9"-1.4" top diameter of 50%-65% of the base diameter
(a) elevation (enlarged)
(b) plan
.6 5"
M in
1.6" - 2.4"
1.
6"
.4
Figure 707.6.2 Numeric Key Layout
(a) 12-key ascending
(b) 12-key descending
1 2 3
4 5 6
7 8 9
* 0 #
7 8 9
4 5 6
1 2 3
* 0 #
Figure 703.2.5 Height of Raised
Characters
LIBRARY
5/ 8"
"0.
2"
Figure 703.3.1 Braille Measurement single braille cell blank cell space between words raised dot no raised dot
Figure 703.3.2 Position of Braille
AREA OF
REFUGE
3/ 8" m in
3/ 8" m in
Figure 703.7.2.1 International Symbol of Accessibility
Figure 703.7.2.2 International TTY Symbol
Figure 703.7.2.3 Volume-Controlled Telephone
Figure 703.7.2.4 International Symbol of Access for
Hearing Loss
Figure 704.2.1.1 Parallel Approach to
Telephone
Figure 704.2.1.2 Forward Approach to
Telephone
Figure 703.4.1 Height of Tactile Characters
Above Floor or Ground
Figure 703.4.2 Location of Tactile Signs at Doors
AREA OF
REFUGE
centered on tactile characters
AREA OF
REFUGE
.00
M ax
M ax
M in
M ax
18" Min
M in distance between corresponding dots from one cell directly below distance between dots in the same cell distance between corresponding dots in adjacent cells distance between dots in the same cell base diameter
C O
M M
U N
IC
A
T
IO
N E
L E
M E
N T
S A
N D
F E
A T
U R
E S
SHEET TITLE:
CHECKED BY:
PROJECT NO.:
ISSUE DATE:
DESIGNED BY:
DRAWN BY:
SHEET NUMBER:
A
B
D
1 2 3 4
C
F ul l s iz e x3
6;
H al f s iz e x1
A
B
D
C
1 2 3 4 5
600 E. 7th Street Sioux Falls, SD 57103 phone: 605.271.1144 stonegrouparchitects.com
© Copyright 2024
4/
/2
1:
:0
P
M
G-002
221060
04.26.2024
JM, JH, JD
JH/JD
JM
A V
IA
T
IO
N
S U
P P
O R
T F
A C
IL
IT
Y S
D A
R N
G A
A S
F R
A P
ID
C
IT
Y
R E
G
IO
N A
L A
IR
P
O R
T
ACCESSIBILITY DETAILS
Permit / Bid Set
SHEET TITLE:
CHECKED BY:
PROJECT NO.:
ISSUE DATE:
DESIGNED BY:
DRAWN BY:
SHEET NUMBER:
A
B
D
1 2 3 4
C
F ul l s iz e x3
6;
H al f s iz e x1
A
B
D
C
1 2 3 4 5
600 E. 7th Street Sioux Falls, SD 57103 phone: 605.271.1144 stonegrouparchitects.com
© Copyright 2024
4/
/2
3:
:1
P
M
G-003
221060
04.26.2024
JM, JH, JD
JH/JD
JM
A V
IA
T
IO
N
S U
P P
O R
T F
A C
IL
IT
Y
S D
A R
N G
A A
S F
R A
P
ID
C
IT
Y R
E G
IO
N
A L
A
IR
P O
R T
LIFE SAFETY CODE REVIEW
Permit / Bid Set
HORIZONTAL BUILDING SEPARATION
ALLOWANCE
NA NA 510.2 FOR
REQUIREMENTS
INCIDENTAL USES SEPARATION IF REQUIRED NA NA TABLE 509
SEPARATION OF OCCUPANCIES IF REQUIRED H AND B EXISTING 1 HOUR RATED WALLS TABLE 508.4
ALLOWABLE AREA NA NA TABLE 506.2
SPRINKLER SYSTEM FULL SPRINKLER SYSTEM NFPA 13
ALLOWABLE NUMBER OF STORIES ABOVE
GRADE PLANE
NA TABLE 504.4
ALLOWABLE BUILDING HEIGHT IN FEET
ABOVE GRADE
NA NA TABLE 504.3
BUILDING CONSTRUCTION TYPE II-A TABLE 503
ADDRESS IDENTIFICATION ON STREET SIDE, AT MAIN DOOR. 501.2
BUILDING HEIGHTS & AREAS SPRINKLER SYSTEM INSTALLED IBC CHAPTER 5
SPECIALTY OCCUPANCY REQUIREMENTS (PARKING GARAGE INFORMATION?) IBC CHAPTER 4
B,S,H-4
OCCUPANCY GROUP IBC CHAPTER 3
BUILDING CLASSIFICATION
HEIGHT NA NA
LOT FRONTAGE NA NA
STREET SIDE YARD NA NA
SIDE NA NA
REAR NA NA
FRONT NA NA
SETBACKS REQ
ZONING
CHAPTER
NUMBER OF VAN ACCESSIBLE STALLS
REQUIRED
NA
NUMBER OF ACCESSIBLE STALLS REQUIRED NA
NUMBER OF STALLS REQUIRED NA NA
PARKING REQ:
ZONING
CHAPTER
IBC REQUIRED/AHJ/ALLOWED ACTUAL PROVIDED 1/3
PERMIT REQ'D Y/N: YES
ZONE: PUD
AHJ: State of South Dakota
* STATE AND LOCAL ORDINANCES AS APPLY
* AMERICANS WITH DISABILITIES ACT (ADA) 2010
* AMERICAN NATIONAL STANDARDS INSTITUTE (ANSI 117.1) 2003
* UNIFORM PLUMBING CODE 2015
* NFPA 13 (Exeption 8.14.1.2)
* NATIONAL ELECTRICAL CODE (NEC) 2020
* INTERNATIONAL FIRE CODE 2015
* INTERNATIONAL FUEL GAS CODE 2015
* INTERNATIONAL MECHANICAL CODE 2015
APPLICABLE CODES: * INTERNATIONAL BUILDING CODE (IBC) 2021
SITE AREA: MULTI BUILDING SITE
SITE ADDRESS: Army Aviation Support Facility - Rapid City Airport, SD Rapid City, SD
PARCEL NO: GOV'T LOT 1 SEC. 20-99-36 SD Nat. Guard
South Dakota Army Reserve National Guard CFMO# 466535
PROJECT NO: 221060
CODE REVIEW
CARBON MONOXIDE DETECTORS EXISTING
4TH FLR NA NA
3RD FLR NA NA
2ND FLR EXISTING EXISTING
1ST FLR EXISTING EXISTING
NUMBER OF FEC REQUIRED PER FLR
MAX TRAVEL DISTANCE TO FEC 75 FEET >75 FEET TABLE 906.3(1)
MAXIMUM FLOOR AREA FOR
EXTINGUISHER
11,250 SQ FT >11,250 SQ FT
MAXIMUM FLOOR AREA PER UNIT OF
CLASS A
3,000 SQ FT >3,000 SQ FT
MINIMUM RATED SINGLE EXITNGUISHER EXT TYPE = 2A EXISTING NFPA 10
FIRE EXTINGUISHER REQUIREMENTS
FIRE DEPARTMENT ACCESS WITHIN 300 FT OF ALL PORTIONS OF THE FIRST
FLOOR OF THE BUILDING
EXISTING
AUTOMATIC SPRINKLER SYSTEM FULL FULL 13 TABLE 903.2
FIRE PROTECTION SYSTEMS REVIEW INTERNATIONAL FIRE CODE (IFC) IBC CHAPTER 9
INTERIOR FINISHES IBC CHAPTER 8
DRAFT STOPS IN ATTIC NA 717.4.3
DRAFT STOPS IN FLOORS NA 717.3.3
FIRE WALL 706.1 MOST RESTRICTIVE OCCUPANCY SHALL
GOVERN IF FIRE WALLS ARE REQUIRED
706.1
MAXIMUM AREA OF EXTERIOR WALL
OPENINGS
UNLIMITED (EXCEEDS 30'-0" AND IS FULLY
SPRINKLED BUILDING)
TABLE 705.8
FIRE WALLS REQUIRED (Y/N) NO SECTION 706
TABLE 705.8
BUILDINGS ON THE SAME LOT (Y/N) YES, USE LINE SECTION 705.3
30 FEET OR GREATER 20 FEET TABLE 705.2
GREATER THAN 3 FEET TO LESS THAN
30 FEET
24 INCHES PLUS 8 INCHES FOR EVERY FOOT OF
FSD BEYOND 3 FEET OR FRACTION THEREOF
TABLE 705.2
GREATER THAN 2 FEET TO 3 FEET 24 INCHES TABLE 705.2
O FEET TO 2 FEET PROJECTIONS NOT PERMITTED PROJECTIONS FROM WALLS OF TYPE I OR TYPE II
CONSTRUCTION SHALL BE OF NONCOMBUSTIBLE
MATERIALS OR COMBUSTIBLE MATERIALS AS
ALLOWED BY SECTIONS 1406.3 & 1406.4
TABLE 705.2
EXTERIOR PROJECTIONS NON-RATED TABLE 705.2
SYSTEM IN PLACE SPRINKLER SYSTEM INSTALLED
FIRE & SMOKE PROTECTION IBC CHAPTER 7
JOINING DOORS NA
UNIT DOORS NA
RATED WALL OPENINGS AT CORRIDORS
SHAFT WALL 1 NA
ELEVATOR 1 NA
STAIRS 1 CMU
CORRIDOR RATING 1 CMU
ROOF CONSTRUCTION 1
FLOOR CONSTRUCTION 1 NA
NON BEARING WALLS AND PARTITIONS -
INTERIOR
TABLE 601
NONBEARING WALLS AND PARTITIONS -
EXTERIOR
Less than 30' requires 1 hour, greater than 30' requires no rating. TABLE 602
INTERIOR 1 CMU TABLE 601
EXTERIOR 1 TABLE 601
BEARING WALLS 1 CMU
PRIMARY STRUCTURE 1 CMU TABLE 601
CONSTRUCTION TYPE: II-A IBC CHAPTER 6
IBC REQUIRED/AHJ/ALLOWED ACTUAL PROVIDED 2/3
See Chapter 6 for Rated assemblies
UL-RATED SYSTEMS AND DESIGN
NUMBER SEE WALL TYPE LEGEND / BUILDING SECTIONS
SOUND TRANSMISSION EXISTING SECTION 1207
LABELING FIRE WALLS LABEL ALL FIRE WALLS ABOVE ALL ACT CEILINGS. SECTION 703.7
MISCELLANEOUS INFORMATION
SPECIALTY REQUIREMENTS NONE
REQUIRED? NA
ELEVATORS & CONVEYING SYSTEMS CHAPTER 30
SERVICE SINK 1 1 TABLE 2902.1
DRINKING FOUNTAINS 1 PER 100 = 3 2 TABLE 2902.1
LAVATORIES - FEMALE 1 PER 40 = 4 4
LAVATORIES - MALE 1 PER 40 = 4 7 TABLE 2902.1
WATER CLOSETS - FEMALE 1 PER 25 = 6 4
WATER CLOSETS - MALE 1 PER 25 = 6 15 TABLE 2902.1
OCCUPANCY # 255
MINIMUM NUMBER OF REQUIRED
PLUMBING FIXTURES
REQUIRED TYPE OF FIXTURES PROVIDED TYPE OF FIXTURE TABLE 2902.1
PLUMBING SYSTEMS CHAPTER 29
SPECIAL OCCUPANCIES NONE SECTION 1108
ACCESSIBLE SHOWER UNITS 2 2 ROLL-IN SHOWERS TABLE
1107.6.1.1
ACCESSIBLE ROUTES AT LEAST ONE ACCESSIBLE ROUTE. PROVIDED. SECTION 1107.4
ACCESSIBLE PARKING SPACES EXISTING EXISTING TABLE 1106.1
ACCESSIBLE ENTRANCES MINIMUM 60% 2 /3 ENTRANCES ARE ACCESSIBLE SECTION 1105
ACCESSIBLE ROUTE AT LEAST ONE ACCESSIBLE ROUTE. MAIN DOOR ON STREET SIDE. SECTION 1104
REQUIREMENTS APPLICABLE EXCEPTIONS? NONE SECTION 1103
ACCESSIBILITY 68 UNITS CHAPTER 11
DEAD END CORRIDOR LENGTH 50'-0" SEE CODE PLANS 1020.4
MAX COMMON PATH OF TRAVEL 75'-0" SEE CODE PLANS TABLE 1006.3.2
H-4 = 75'
ALLOWABLE EXIT ACCESS TRAVEL
DISTANCE
B = 100' TABLE 1017.2
AREA OF REFUGE REQUIRED NO FULLY SPRINKLED BUILDING SECTION 1009
MEANS OF EGRESS ILLUMINATION
REQUIRED?
YES SEE SECTION
MINIMUM NUMBER OF EXITS OR ACCESS
TO EXITS PER STORY
Existing Existing TABLE 1006.3.1
SPECIAL EXCEPTIONS NONE 1006.2
ONE EXIT REQUIRED? Existing Existing TABLE 1006.2.1
NUMBER OF EXITS & EXIT ACCESS
DOORWAYS REQUIRED
2 (IN AREAS WITH MORE THAN 50 OCC.) Teaching rooms SECTION 1006
MINIMUM CORRIDOR WIDTH 44" Existing TABLE 1020.2
DOOR SWINGS ≥ 50 OCCUPANT = SWING IN DIRECTION OF
TRAVEL
DOORS (multiply by 0.2 inches/occupant) SEE CODE PLANS 1005.7.1
STAIRWAYS (multiply by 0.3 inches/occupant - sprinkled throughout)
SEE CODE PLANS 1005.3.1
MEANS OF EGRESS SIZING
Aircraft Hanger 500 gross Existing
Assembly 15 net Existing
Business 150 gross Existing
LIST TYPE LIST FACTOR TOTAL OCCUPANTS TABLE 1004.1.2
OCCUPANCY LOAD - FUNCTION OF SPACE
(LIST BELOW)
OCCUPANT LOAD FACTOR
MEANS OF EGRESS IBC CHAPTER 10
IBC REQUIRED/AHJ/ALLOWED ACTUAL PROVIDED 3/3
NO. ISSUE LOG DATE
1 Permit / Bid Set 04-26-2024
2 Addendum 1 04-16-2026
UP
DN
16.2"
60.0"
16.2"
30.0"
16.2"
30.0"
6.0"
30.0"
6.0"
30.0"
15.3"
30.0"
150 SF
FLIGHT INST.
(AIRCRAFT)
140 SF
FLIGHT INST.
(AIRCRAFT)
95 SF
FLIGHT INST.
(SAFETY)
131 SF
FACILITY
STORAGE
243 SF
FLIGHT
PLANNING
141 SF
ADMIN
245 SF
AIRCRAFT PILOT
SUPERVISION
742 SF
122B
BRIEFING ROOM
B
395 SF
MEN LATRINE
495 SF
MEN LOCKER
ROOM
117 SF
UNISEX
279 SF
JANITORIAL &
STORAGE
132 SF
OFFICE
201 SF
FLIGHT
SURGEON
128 SF
OFFICE
202 SF
MAINT. OFFICE
317 SF
MEN LOCKER
ROOM
163 SF
WOMEN
SHOWER
657 SF
148A
UNIT STORAGE
180 SF
148B
VAULT
1381 SF
CLASSROOM
567 SF
122A
BRIEFING ROOM
A
294 SF
CONFERENCE
ROOM
201 SF
SECRETARY
346 SF
STORAGE
207 SF
ADMIN OFFICE
251 SF
FACILITY
COMMANDER
176 SF
FLIGHT
INSTRUCTOR
130 SF
OFFICE
131 SF
VENDING
314 SF
MEN SHOWER
129 SF
WOMEN TOILET430 SF
WOMEN LOCKER
ROOM 109 SF
MEN SHOWER
160 SF
OFFICE
69 SF
ASSET
157 SF
OFFICE
651 SF
FLIGHT OPS
432 SF
OFFICE
484 SF
OFFICE
396 SF
MECHANICAL
471 SF
STORAGE
962 SF
EXERCISE ROOM
1222 SF
ALSE AREA
5316 SF
HANGAR5990 SF
HANGAR AREA B
20224 SF
HANGAR AREA A
22.3622.31
22.36
75'-0"
75'-0"
75'-0"
75'-0"
10.42
10.42
10.42
10.42
10.42
10.42
10.42
10.42
10.42
10.42
10.14
10.14
22.13A
75'-0"
75'-0"
'-0
75'-0"
75'-0"
75'-0"
HATCH INDICATES AREA OUTSIDE
OF SCOPE OF WORK
137A
MECH
A. ANY DISCREPANCIES OR CONFLICTS FOUND IN THE VARIOUS PARTS OF THE CONSTRUCTION
DOCUMENTS SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT AND THE OWNER BEFORE
PROCEEDING WITH THE WORK.
B. SMOKE SEALS ON ALL RATED DOORS.
C. SEE MECHANICAL, ELECTRICAL AND PLUMBING DRAWINGS FOR ADDITIONAL INFORMATION.
D. WITH THE ADDITION OF THE NEW SPRINKLER SYSTEM, SOME EXISTING WALL RATINGS ARE NO
LONGER REQUIRED, SEE BOTH EXISTING AND NEW CODE PLANS FOR CLARIFICATIONS.
GENERAL CODE PLAN NOTES:
CODE PLAN LEGEND
0.0"
0.0"
OCCUPANTS
REQUIRED WIDTH
PROVIDED WIDTH
OCCUPANT LOAD
RATED WALL KEY
1-HOUR WALL
2-HOUR WALL
SHEET TITLE:
CHECKED BY:
PROJECT NO.:
ISSUE DATE:
DESIGNED BY:
DRAWN BY:
SHEET NUMBER:
A
B
D
1 2 3 4
C
F ul l s iz e x3
6;
H al f s iz e x1
A
B
D
C
1 2 3 4 5
600 E. 7th Street Sioux Falls, SD 57103 phone: 605.271.1144 stonegrouparchitects.com
© Copyright 2024
4/
/2
1:
:1
P
M
G-004
221060
04.26.2024
JM, JH, JD
JH/JD
JM
A V
IA
T
IO
N
S U
P P
O R
T F
A C
IL
IT
Y S
D A
R N
G A
A S
F R
A P
ID
C
IT
Y
R E
G
IO
N A
L A
IR
P
O R
T
LIFE SAFETY PLAN - NEW
WALL RATINGS
Permit / Bid Set
1/16" = 1'-0" A2
CODE PLAN - NEW / REVISED WALL RATINGS
NORTH
KEYNOTES_SGA
Key Value Keynote Text
10.14 HORIZONTAL SURFACE MOUNTED BABY CHANGING STATION
10.42 WALL-MOUNTED FIRE EXTINGUISHER
22.13A ADA COMPLIANT SHOWER WITH FOLDING ADA COMPLIANT SHOWER SEAT - SEE PLUMBING.
22.31 MOP SINK - SEE PLUMBING.
22.36 WATER FOUNTAIN - EXISTING TO REMAIN IN PLACE
22.3622.31
22.36
10.42
10.42
10.42
10.42
10.42
10.42
10.42
10.42
10.42
10.42
HATCH INDICATES AREA OUTSIDE
OF SCOPE OF WORK
A. ANY DISCREPANCIES OR CONFLICTS FOUND IN THE VARIOUS PARTS OF THE CONSTRUCTION
DOCUMENTS SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT AND THE OWNER BEFORE
PROCEEDING WITH THE WORK.
B. SMOKE SEALS ON ALL RATED DOORS.
C. SEE MECHANICAL, ELECTRICAL AND PLUMBING DRAWINGS FOR ADDITIONAL INFORMATION.
D. WITH THE ADDITION OF THE NEW SPRINKLER SYSTEM, SOME EXISTING WALL RATINGS ARE NO
LONGER REQUIRED, SEE BOTH EXISTING AND NEW CODE PLANS FOR CLARIFICATIONS.
GENERAL CODE PLAN NOTES:
CODE PLAN LEGEND
0.0"
0.0"
OCCUPANTS
REQUIRED WIDTH
PROVIDED WIDTH
OCCUPANT LOAD
RATED WALL KEY
1-HOUR WALL
2-HOUR WALL
SHEET TITLE:
CHECKED BY:
PROJECT NO.:
ISSUE DATE:
DESIGNED BY:
DRAWN BY:
SHEET NUMBER:
A
B
D
1 2 3 4
C
F ul l s iz e x3
6;
H al f s iz e x1
A
B
D
C
1 2 3 4 5
600 E. 7th Street Sioux Falls, SD 57103 phone: 605.271.1144 stonegrouparchitects.com
© Copyright 2024
4/
/2
1:
:1
P
M
G-005
221060
04.26.2024
JM, JH, JD
JH/JD
JM
A V
IA
T
IO
N
S U
P P
O R
T F
A C
IL
IT
Y S
D A
R N
G A
A S
F R
A P
ID
C
IT
Y
R E
G
IO
N A
L A
IR
P
O R
T
LIFE SAFETY PLAN -
EXISTING WALL RATINGS
Permit / Bid Set
1/16" = 1'-0" A2
CODE PLAN - EXISTING WALL RATINGS
NORTH
KEYNOTES_SGA
Key Value Keynote Text
10.42 WALL-MOUNTED FIRE EXTINGUISHER
22.31 MOP SINK - SEE PLUMBING.
22.36 WATER FOUNTAIN - EXISTING TO REMAIN IN PLACE
1/2" 1"0" 2"SCALE: FULL
XC1 R1
XX" Ø X
XX'-X" XX'-X"
X
XN
XXNNN
XN
XXNNN
XN
XXNNN
F1
A
HSS _x_x_
B1
20GA TYPE 'W3' MTL DECK
PC S
PAN
Hx R15:12
B
B
GENERAL STRUCTURAL NOTES INDEX TO STRUCTURAL SHEETSSYMBOLS LEGEND
COORDINATE SYSTEM
S J
W--x--
(XXX'-XX")
ELEVATION
INDICATOR
CUT SECTION
INDICATOR
WALL
REINFORCING
INDICATOR
PC SPAN
IDENTIFIER
STEP TOP OF
WALL INDICATOR
PIER TAG CALLOUT INDICATOR
ROOF SLOPE
INDICATOR
STEP TOP OF
FOOTING
IDENTIFIER
MASONRY PIER
INDICATOR
CORNER REINF
INDICATOR
CONTINUOUS
BEAM
INDICATOR
MATCH LINE INDICATOR
PLAN NORTH ORIENTED 90°
TO THE SHEET W/ MAGNETIC
NORTH (OPTIONAL)
SHEET TYPE DESIGNATORS
SHEET IDENTIFICATION
SHEET TYPE
DESIGNATOR
SHEET SEQUENCE
NUMBER 01-99
MODIFIER
CHARACTER
DISCIPLINE
CHARACTER
-S
AA
DETAIL BUBBLE
INDICATOR
DETAIL/SECTION/PLAN
BLOCK TITLE INDICATOR
EXT ELEVATION
INDICATOR
COLUMN
INDICATOR(S)
KEYNOTE
IDENTIFIER
REVISION
SYMBOL
NNN
0 GENERAL (SYMBOLS LEGEND, NOTES, ETC)
1 PLANS (HORIZONTAL VIEWS)
2 ELEVATIONS (VERTICAL VIEWS)
3 SECTIONS (SECTIONAL VIEWS)
4 LARGE SCALE VIEWS (PLANS, ELEV, OR SECTIONS, NOT DETAILS)
5 DETAILS
6 SCHEDULES AND DIAGRAMS
7 USER DEFINED
8 USER DEFINED
9 3D REPRESENTATIONS (ISOMETRICS, PERSPECTIVES, PHOTOGRAPHS)
A1
54321
FOOTING/PIER
IDENTIFIER
STEP
INDICATOR
HOLDOWN
INDICATOR
BEAM
INDICATOR(S)
MOMENT
INDICATOR
DECK INDICATOR
SHEAR WALL
INDICATOR
LINTEL
INDICATOR
RAFTER
INDICATOR
ASTERISK
INDICATOR
SLOPE
INDICATOR
WORK POINT
INDICATOR
54321
D
B
A
C
D
B
A
C
A3
C5C4
D4
C3
D3
XN
ELEVATION INDICATOR
SECTION
INDICATOR
COLUMN/FND
GRID INDICATOR
SLAB JOINT
INDICATOR
STRUCTURAL HATCH PATTERNS
BRICK
CONCRETE
NATIVE
UNDISTURBED
SOIL
BACKFILL/FILL
ENGINEERED FILL
DRAINAGE
COURSE
GYPSUM
BOARD
WD- BLKG
OR SHIM
PLYWOOD/OSB
/PARTICLE BD
WD- GLUED
/LAMINATED
WOOD-
CONTINUOUS
FRAMING
INSUL/FIRE
SAFING
METAL FLOOR
GRATING
GROUT
RIGID
INSUL/ICF/SIP
/EIFS SYSTEMS
METALS
MORTAR
CMU
ROUGH LOG
WALL
WOOD STUD
BRG WALL
CONC WALL
HOLDOWN
(BLOCKOUT)
STONE/
ROCK WALL
C1
Hx
NTRUE
NORTH
CONT
MC-x
-xx"
/REF - ---
/REF - ---
INSULATED
PRECAST WALL
SW
-x
SOLID PRECAST
WALL
CONCRETE PROPERTIES
LOCATION
28 DAY
COMPRESSIVE
STRENGTH
ENTRAINED
AIR
SLUMP
MAX W/C
RATIO
FOOTINGS
INTERIOR SLABS
FND WALLS & ALL
OTHER CONC
EXTERIOR SLABS
3,500 PSI
4,500 PSI
4,000 PSI
5,000 PSI
4.0% - 6.0%
5.0% - 7.0%
≤ 3.0%
5.0% - 7.0%
5" +/- 1"
4"+/- 1"
3" +/- 1"
3" +/ - 1"
0.55
0.45
0.5
0.40
POST INSTALLED ANCHORS & REBAR
ANCHOR TYPE
ADHESIVE ANCHORS /
REBAR IN CONCRETE
REMARKS
ADHESIVE ANCHORS / REBAR IN
CONCRETE W/ > 12" EMBEDMENT
PRODUCT
HILTI HIT - HY 200 V3
SIMPSON AT-XP
HILTI HIT - RE 500 V3
SIMPSON SET-3G
ADHESIVE ANCHORS /
REBAR IN GROUT FOR
HOLLOW MASONRY
HILTI HIT - HY 270
SIMPSON SET-XP
PROVIDE
MANUFACTURER'S
RECOMMENDED
SCREEN TUBES IN
HOLLOW MASONRY
---EXPANSION ANCHORS
IN CONCRETE
HILTI KWIK BOLT TZ
SIMPSON STRONG
BOLT 2
EXPANSION ANCHORS IN
GROUTED MASONRY
HILTI KWIK BOLT 3
SIMPSON STRONG
BOLT 2
SCREW ANCHORS IN CONCRETE
OR GROUTED MASONRY
SIMPSON TITEN HD
1. STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION WITH JOB
SPECIFICATIONS AND ARCHITECTURAL, MECHANICAL, ELECTRICAL, PLUMBING AND
SITE DRAWINGS. CONSULT THESE DRAWINGS FOR SLEEVES, DEPRESSIONS AND
OTHER DETAILS NOT SHOWN ON STRUCTURAL DRAWINGS.
2. ALL DIMENSIONS AND CONDITIONS MUST BE VERIFIED IN THE FIELD. ANY
DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER BEFORE
PROCEEDING WITH THE AFFECTED PART OF THE WORK.
3. THE STRUCTURE IS DESIGNED TO BE SELF SUPPORTING AND STABLE AFTER THE
BUILDING IS COMPLETE. IT IS THE CONTRACTOR'S SOLE RESPONSIBILITY TO
DETERMINE ERECTION PROCEDURES AND SEQUENCE TO ENSURE SAFETY OF THE
BUILDING AND ITS COMPONENTS DURING ERECTION. THIS INCLUDES THE ADDITION
OF NECESSARY SHORING, SHEETING, TEMPORARY BRACING (AND ACCOMPANYING
FOOTINGS), GUYS OR TIE-DOWNS.
4. ADDITIONAL OBSERVATIONS AS A RESULT OF REJECTION OF WORK COMPLETED
AND/OR ADDITIONAL OBSERVATIONS DUE TO THE DEFICIENCIES IN WORK OBSERVED
WILL BE AT THE EXPENSE OF THE CONTRACTOR.
5. ALL STRUCTURAL SHOP DRAWINGS TO BE REVIEWED BY JOB SUPERINTENDENT IN
ADDITION TO ALL PERSONNEL DEEMED NECESSARY BY CONTRACTOR PRIOR TO
SUBMITTAL TO ENGINEER FOR APPROVAL.
6. ALL SHOP DRAWINGS TO BE REVIEWED BY ALBERTSON ENGINEERING INC. SHALL
HAVE ELECTRONIC COPIES PROVIDED TO ALBERTSON ENGINEERING INC. FOR
REVIEW. AN ELECTRONIC MARKED SET OF THOSE DRAWINGS WILL BE RETURNED TO
THE CONTRACTOR. NO ADDITIONAL HARD COPIES OF THE SHOP DRAWINGS NEED TO
BE PROVIDED TO ALBERTSON ENGINEERING INC., ALTHOUGH OTHER PARTIES MAY
REQUIRE HARD COPIES OF THE MARKED UP DRAWINGS. THESE REQUIREMENTS ARE
IN ADDITION TO THE TYPICAL PROJECT SHOP DRAWING SUBMITTAL REQUIREMENTS
STATED IN THE PROJECT SPECIFICATIONS.
7. THE DESIGN OF THE STRUCTURE SHOWN IN THESE CONSTRUCTION DOCUMENTS IS
FOR THE ONE-TIME USE AT THE SPECIFIC SITE REFERENCED IN THE GEOTECHNICAL
REPORT.
MINIMUM SLEEVE SPACING SHALL BE TWO DIAMETERS CENTER TO CENTER TO THE
LARGER SLEEVE OR 6" CLEAR BETWEEN SLEEVES, WHICHEVER IS GREATER. PRIOR TO
CONSTRUCTION SLEEVE LOCATIONS AND SIZES SHALL BE APPROVED BY THE
STRUCTURAL ENGINEER OF RECORD.
1. SHALL BE ASTM F1554, GR. 36 ROD WITH THREADED ENDS. PROVIDE HOT DIP
GALVANIZE FINISH ON ALL ANCHOR BOLTS PERMANENTLY EXPOSED TO EXTERIOR
OR IN CONTACT WITH PRESSURE TREATED LUMBER.
2. THREADED ROD EMBEDMENT DEPTH SPECIFIED IN THE DRAWINGS SHALL BE FROM
TOP OF CONCRETE TO TOP OF DOUBLE NUT.
1. CONCRETE TESTING SHALL BE PAID FOR BY THE OWNER. TESTING LABORATORY SHALL
PERFORM THE FOLLOWING TEST ON CAST-IN-PLACE CONCRETE:
A. ASTM C143 - "STANDARD TEST METHOD FOR SLUMP OF PORTLAND CEMENT
CONCRETE."
B. ASTM C39 - "STANDARD TEST METHOD FOR COMPRESSIVE STRENGTH OF
CYLINDRICAL CONCRETE SPECIMENS. A SEPARATE TEST SHALL BE CONDUCTED
FOR EACH CLASS, FOR EVERY 50 CUBIC YARDS (OR FRACTION THEREOF), PLACED
PER DAY. REQUIRED CYLINDER(S) QUANTITIES AND TEST AGE AS FOLLOWS:
a. (1) AT 7 DAYS
b. (2) AT 28 DAYS
c. (1) ADDITIONAL RESERVE CYLINDER TO BE TESTED UNDER THE DIRECTION OF
THE ENGINEER, IF REQUIRED. IF 28 DAY STRENGTH IS ACHIEVED, THE
ADDITIONAL CYLINDER(S) MAY BE DISCARDED.
C. TESTING SHALL BE BASED UPON CONCRETE TAKEN AT POINT OF PLACEMENT.
D. IN ADDITION TO TYPICAL TESTING REQUIREMENTS, SLUMP AND AIR CONTENT
SAMPLES SHALL BE TAKEN AT BEGINNING OF FIRST TRUCK PRIOR TO ANY
PLACEMENT AND REPEATED AT THE MIDDLE OF FIRST TRUCK. CONCRETE
PLACEMENT SHALL NOT START IF INITIAL TEST(S) FAIL AND SHALL NOT CONTINUE IF
TEST TAKEN AT MIDDLE OF FIRST LOAD FAILS.
E. IF ANY SLUMP OR AIR CONTENT FAILS DURING PLACEMENT, TESTS SHALL BE
IMMEDIATELY REPORTED AND RETAKEN. IF RETAKEN TESTS FAIL THEN ALL
SUBSEQUENT LOADS MUST BE TESTED AT ARRIVAL AND TEST MUST SHOW
COMPLIANCE PRIOR TO THE CONCRETE IN THAT TRUCK BEING ALLOWED FOR USE
ON PROJECT. ALL COSTS FOR ADDITIONAL TESTING SHALL BE CREDITED TO THE
OWNER.
NO PENETRATIONS SHALL BE MADE IN ANY STRUCTURAL MEMBERS OTHER THAN THOSE
LOCATED ON THESE DRAWINGS WITHOUT PREVIOUS APPROVAL OF THE ENGINEER.
4. COARSE AND FINE AGGREGATES SHALL COMPLY WITH ASTM C33 AND ACI 302.1,
CURRENT VERSIONS.
a. COMPLIANCE WITH THE NON-REACTIVE REQUIREMENTS OF ACI 302.1 SHALL NOT BE
PROVIDED FOR BY THE PROVISION OF ACI 302.1 (SUBSECTION 7.3) THAT EXCLUDES
THE AGGREGATES BEING CLASSIFIED AS DELETERIOUSLY REACTIVE WITH ALKALIES
IF THE AGGREGATE HAS A SATISFACTORY SERVICE RECORD EVALUATION OR WITH
THE ADDITION OF A MATERIAL THAT HAS SHOWN TO PREVENT HARMFUL EXPANSION
DUE TO ALKALI-AGGREGATE REACTION.
b. CONCRETE MIX DESIGN SHALL INCLUDE TEST RECORDS OF THE COMPLIANCE OF THE
AGGREGATE MEETING THE REQUIREMENTS OF ASTM C1260, AND THAT THE
EXPANSION OF THE MORTAR SAMPLE SHALL NOT EXCEED 0.10% WHEN TESTED IN
ACCORDANCE WITH ASTM C1260 AT 14 DAYS. USE OF ADMIXTURES THAT MITIGATE
THE EFFECT OF THE REACTIVE AGGREGATE TO BE PROPOSED IN CONCRETE MIX
SHOP DRAWING MAY BE AN APPROVED APPROACH BY THE ENGINEER TO ALLOW FOR
THE USE OF OTHERWISE REACTIVE AGGREGATES. IF SUCH MITIGATING MEASURES
ARE PROPOSED, THEY MUST BE INCLUDED WITHIN MIX DESIGN SUBMITTAL. THE
ENGINEER IS GIVEN DISCRETION AS TO WHETHER OR NOT TO ACCEPT MITIGATING
MEASURES OR TO MAINTAIN REQUIREMENTS THAT NONREACTIVE AGGREGATES
MUST BE USED. AT A MINIMUM, SUCH DOCUMENTATION MUST SHOW THAT REACTIVE
AGGREGATES USED IN COMBINATION WITH A GIVEN AMOUNT OF ADMIXTURE
RESULTS IN THE EXPANSION OF THE MORTAR SAMPLE BEING LESS THAN 0.10% WHEN
TESTED IN ACCORDANCE WITH ASTM C1567 AT 14 DAYS. LIABILITY OF THE
PERFORMANCE OF THE CONCRETE MIX REMAINS SOLELY WITH GENERAL
CONTRACTOR.
c. IF CONCRETE MIXES ARE APPROVED BY THE ENGINEER THAT CONTAIN EITHER FINE
OR COARSE AGGREGATE, THAT EITHER SEPARATELY OR IN COMBINATION EXCEED
THE 0.10% EXPANSION WHEN TESTED ACCORDING TO ASTM C1260, SPECIAL
CONSIDERATIONS MUST BE GIVEN TO SLAB CURING (SLABS ON GRADE AND
ELEVATED SLABS). IN SUCH INSTANCES SLABS SHALL BE CURED USING EITHER A
WET BURLAP OR CONTINUOUS WETTING/FOGGING METHOD FOR SLABS FOR AT
LEAST 10 DAYS. USE OF CURING AND/OR SEALING COMPOUNDS IS NOT ACCEPTABLE
UNTIL THE SLAB HAS CURED A MINIMUM OF 28 DAYS AND THE CONDITIONS FOR THE
APPLICATION OF THE CURING COMPOUND ON THE CONCRETE SLAB SET BY THE
MANUFACTURER’S RECOMMENDATIONS HAVE BEEN MET.
d. ENGINEER HAS SOLE DISCRETION IN DETERMINING ACCEPTABILITY OF A CONCRETE
SLAB THAT IS EXHIBITING ALKALI-SILICA REACTION. FOR SLABS SHOWING AN ALKALI
SILICA REACTION SOLELY WITHIN THE FINE AGGREGATE: A SLAB SHOWING AN
AVERAGE DENSITY OF POPOUTS GREATER THAN 1 PER 8 SQUARE FEET OVER ANY
CONTIGUOUS AREA OF 100 SQUARE FEET OR LARGER, OR ANY AREA WITH A DENSITY
OF 1 POPOUTS PER 2 SQUARE FEET WITHIN ANY AREA UP TO 100 SQUARE FEET
WOULD BE CONSIDERED AS A BASIS FOR THE REJECTION OF THE SLAB FROM WHICH
THOSE SAMPLE AREAS ARE INCLUDED. FOR A ALKALI SILICA REACTION WITHIN THE
COARSE AGGREGATE: THE POPOUT DENSITIES CONSIDERED FOR REJECTION OF THE
CONCRETE SLAB SHALL BE ½ OF THE DENSITIES GIVEN FOR FINE AGGREGATE. THE
EXTENT OF REJECTED SLAB TO BE DETERMINED BY ENGINEER. THE TIME FRAME FOR
OBSERVATION OF ALKALI SILICA REACTIONS AND DETERMINATION OF REJECTION OF
THE CONCRETE SLAB SHALL BE AT LEAST 56 DAYS FROM THE DATE OF POUR.
e. CONCRETE MIXES UTILIZING CRUSHED LIMESTONE AS COARSE AGGREGATE AND
CONTAINING AT LEAST 25% CLASS F FLY ASH AND HAVING A SATISFACTORY SERVICE
RECORD PER ACI 302.1 IS CONSIDERED AN ACCEPTABLE ALTERNATIVE APPROACH TO
THE COMPLIANCE REQUIREMENTS OUTLINED IN PROVISIONS 4a THROUGH 4d ABOVE.
5. THE CONCRETE STRENGTHS SHOWN IN THE SECTION ABOVE AND IN THE
SPECIFICATIONS ARE MINIMUM COMPRESSIVE STRENGTHS. THE ENGINEER SHALL
DETERMINE IF THE CONCRETE IS ACCEPTABLE, OR TO BE REMOVED, OR TO RECEIVE
SPECIAL CURING IF THE COMPRESSIVE STRENGTHS ARE LESS THAN SPECIFIED.
6. WATER REDUCING AGENTS MAY BE USED IN THE CONCRETE MIX. PLASTICIZERS AND
SUPER-PLASTICIZERS MAY BE USED ONLY WHEN WRITTEN PERMISSION OF THE
ENGINEER IS GIVEN.
7. NO SALTS OF ANY KIND MAY BE USED IN CONCRETE BEFORE OBTAINING THE ENGINEER'S
WRITTEN PERMISSION FOR THEIR USE.
SHT NO SHEET NAME
FND
PKG
FRMG
PKG
S-001 STRUCTURAL GENERAL NOTES
S-002 IBC INSPECTION TABLES
S-101 PARTIAL FOUNDATION PLAN
S-102 PARTIAL FRAMING PLAN
S-501 DETAILS
S-601 STANDARD DETAILS / SCHEDULES
S-602 STANDARD DETAILS / SCHEDULES
NOTE:
ANY DRAWINGS INCLUDED IN THE FRAMING PACKAGE CONTAINED WITHIN THIS SET
ARE FOR INFORMATION PURPOSES ONLY AND ARE NOT INTENDED TO BE USED FOR
CONSTRUCTION.
1. ALL CONCRETE SHALL BE PLACED IN ACCORDANCE WITH ACI 301 AND ACI 117 EXCEPT AS
MODIFIED BELOW:
A. ACI 117 ITEM 4.3.1.1 ELEVATIONS OF SLABS-ON-GRADE TOP OF SLAB ELEVATION
SHALL BE WITHIN A 3/8" ENVELOPE EITHER SIDE OF THE THEORETICAL DESIGN
SURFACE.
B. ACI 117 ITEM 4.5.7 FLOOR FINISH TOLERANCES AS MEASURED BY PLACING A
FREESTANDING (UNLEVELED) 10 FT. STRAIGHTEDGE ANYWHERE ON THE SLAB AND
ALLOWING IT TO REST UPON TWO HIGH SPOTS WITHIN 28 DAYS AFTER SLAB
CONCRETE PLACEMENT. THE GAP AT ANY POINT BETWEEN THE STRAIGHT EDGE AND
THE FLOOR SHALL NOT EXCEED 1/4".
2. ALL REINFORCING STEEL TO BE ASTM A615, GRADE 60 (#4 AND LARGER), EXCEPT WHERE
NOTED OTHERWISE. REINFORCING SHALL NOT BE WELDED
3. WELDED WIRE FABRIC TO CONFORM TO ASTM A185 AND SHALL BE FREE FROM OIL,
SCALE, AND RUST. PLACE WWF IN ACCORDANCE WITH THE TYPICAL PLACING DETAILS OF
ACI STANDARDS AND THE SPECIFICATIONS. MINIMUM LAPS SHALL BE ONE SPACE PLUS 2"
4. ALL REINFORCING STEEL BARS TO BE DETAILED AND PLACED IN ACCORDANCE WITH THE
LATEST ACI MANUALS.
5. LAP ALL REINFORCING SPLICES IN CONCRETE A MINIMUM OF 48 BAR DIAMETERS OR 24
INCHES, WHICHEVER IS GREATER, UNLESS NOTED OTHERWISE ON DRAWINGS (CLASS B
SPLICE).
6. PROVIDE CORNER BARS OF SAME BAR DIAMETER AS SPECIFIED FOR THE WALL, BEAM OR
FOOTING. PROVIDE MINIMUM OF 40 BAR DIAMETER LAP FOR ALL CORNER BARS, UNLESS
NOTE OTHERWISE.
7. PROVIDE FOUNDATION DOWELS AS SHOWN. MINIMUM SIZE DOWELS TO BE #4, UNLESS
OTHERWISE NOTED. ALL VERTICAL REINFORCING STEEL IN COLUMNS AND PIERS, OR
VERTICAL REINFORCING IN WALLS, SHALL BE DOWELED INTO THE FOOTINGS WITH SAME
SIZE AND QUANTITY DOWEL AS THE VERTICAL REINFORCING.
8. WHERE SHOWN ON THE DRAWINGS, PROVIDE WELD PLATES, WELDMENTS, OR
CONCRETE INSERTS FOR FASTENING AND SECURING OTHER COMPONENTS. CONCRETE
INSERTS SHALL BE FURNISHED BY THE CONTRACTOR REQUIRING THEM AND INSTALLED
BY THE CONTRACTOR CASTING THE CONCRETE AROUND THEM. CLIP ANGLES SHALL BE
FURNISHED BY THE CONTRACTOR REQUIRING THEM.
9. REINFORCING STEEL SHALL RECEIVE CONCRETE COVER AS FOLLOWS:
DESCRIPTION MINIMUM COVER
CAST AGAINST & PERMANENTLY 3"
EXPOSED TO EARTH
EXPOSED TO EARTH OR WEATHER
#6 THROUGH #18 BARS 2"
#5 BARS OR SMALLER 1 1/2"
NOT EXPOSED TO EARTH OR WEATHER
OR IN CONTACT WITH THE GROUND, SLABS
AND WALLS
#11 BARS OR SMALLER 3/4"
#14 AND #18 1 1/2"
BEAMS AND COLUMNS 1 1/2"
SHELLS, FOLDED PLATE MEMBERS:
NO. 6 BAR AND LARGER 3/4"
NO. 5 BAR, W31 OR D31 WIRE AND SMALLER 1/2"
10. PROVIDE TWO (2) #5'S, ONE AT EACH FACE, UNLESS NOTED OTHERWISE, AROUND ALL
OPENINGS LESS THAN 12"x12" IN CAST-IN-PLACE CONCRETE. EXTEND REINFORCING 2'-0"
BEYOND OPENING IN BOTH DIRECTIONS. CONTACT ENGINEER FOR ALL OPENINGS
GREATER THAN 12"x12" FOR DESIGN.
11. COLD WEATHER AND HOT WEATHER PROVISIONS OF ACI 306 AND 305 (CURRENT
EDITIONS), RESPECTIVELY, SHALL BE MAINTAINED.
12. UNLESS NOTED OTHERWISE ALL UNDER SLAB VAPOR RETARDERS SHALL CONFORM TO
THE REQUIREMENTS OF ASTM E1745 CLASS A AND SHALL BE INSTALLED AS PER
MANUFACTURER'S RECOMMENDATIONS.
THE STRUCTURAL SYSTEM FOR THIS BUILDING HAS BEEN DESIGNED WITH THE
FOLLOWING SUPERIMPOSED LOADINGS BASED ON A RISK CATEGORY III:
ROOF:
SNOW LOAD 34 PSF + DRIFT
GROUND SNOW LOAD 40 PSF
SNOW EXPOSURE FACTOR 1.0
SNOW THERMAL FACTOR 1.0
SNOW IMPORTANCE FACTOR 1.1
DEAD LOAD 20 PSF
LIVE LOAD 20 PSF (REDUCIBLE)
GENERAL NOTES:
PLUMBING SLEEVES:
DESIGN LOADS:
PENETRATIONS:
CONCRETE MIX DESIGN (CONTINUED):
CONCRETE AND REINFORCING PLACEMENT:
CONCRETE TESTING:
ANCHOR RODS:
MM/DD/YY
OF E IS S
E
T
MICHAEL D.
ALBERTSON
E R
U O
S
E T
S I
G
D
E R R
P R
E
DA KH
O
T
A
E R
O. NG
L A
NO
N G
I N
E
SHEET TITLE:
CHECKED BY:
PROJECT NO.:
ISSUE DATE:
DESIGNED BY:
DRAWN BY:
SHEET NUMBER:
A
B
D
1 2 3 4
C
F ul l s iz e x3
6;
H al f s iz e x1
A
B
D
C
1 2 3 4 5
© Copyright 2023
1 PERMIT / BID SET 04-26-2024
4/
/2
9:
:2
A
M
S-001
2023-259
04-26-2024
MDA
AEI
DEL
A V
IA
T
IO
N
S U
P P
O R
T F
A C
IL
IT
Y
S D
A R
N G
A A
S F
R A
P
ID
C
IT
Y R
E G
IO
N
A L
A
IR
P O
R T
STRUCTURAL GENERAL
NOTES
04-26-2024
• 2021 INTERNATIONAL BUILDING CODE.
• ACI 318-19 BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE AND
COMMENTARY.
• AISC 360-16 SPECIFICATIONS FOR STRUCTURAL STEEL BUILDINGS.
• ASCE 7-16 MINIMUM DESIGN LOADS AND ASSOCIATED CRITERIA FOR BUILDINGS AND
OTHER STRUCTURES.
• SDI RD-2017 STANDARD FOR STEEL ROOF DECK.
• SJI 100-15 STANDARD SPECIFICATIONS, LOAD TABLES AND WEIGHT TABLES FOR
STEEL JOISTS & JOIST GIRDERS.
• TMS 402-16 BUILDING CODE FOR MASONRY STRUCTURES.
DESIGN CODES:
ANCHORING ADHESIVE SHALL BE A TWO-COMPONENT SOLID EPOXY BASED SYSTEM
SUPPLIED IN MANUFACTURER'S STANDARD SIDE-BY-SIDE CARTRIDGE AND DISPENSED
THROUGH A STATIC-MIXING NOZZLE SUPPLIED BY THE MANUFACTURER. EPOXY SHALL
MEET THE MINIMUM REQUIREMENTS OF ASTM C-881 SPECIFICATION FOR TYPE I, II, IV,
AND V, GRADE 3, CLASS B, AC, AND D AND MUST DEVELOP A MINIMUM 12,650 PSI
COMPRESSIVE YIELD STRENGTH AFTER 7 DAY CURE. EPOXY MUST HAVE A HEAT
DEFLECTION TEMPERATURE OF A MINIMUM 136 FA (58 AC). ADHESIVE SHALL BE EPOXY-
TIE SET FROM SIMPSON STRONGTIE OR THE HILTI HIT HY-200 ADHESIVE SYSTEM.
ANCHORS SHALL BE INSTALLED PER THE MANUFACTURERS INSTRUCTIONS.
HIGH STRENGTH EPOXY:
1. ALL PERSONNEL INSTALLING POST-INSTALLED ANCHORS SHALL HAVE COMPLETED
INSTALLATION TRAINING FROM THE MANUFACTURER FOR ALL OF THE ANCHORING
PRODUCTS SPECIFIED. TRAINING MUST HAVE BEEN COMPLETED NO MORE THAN 5 YEARS
FROM THE DATE OF PROJECT INITIATION. IF TRAINING HAS NOT BEEN COMPLETED OR IF
TRAINING OCCURRED MORE THAN 5 YEARS BEFORE THE DATE OF PROJECT INITIATION,
THE CONTRACTOR SHALL ARRANGE AN ANCHOR MANUFACTURER'S REPRESENTATIVE TO
PROVIDE ON-SITE INSTALLATION TRAINING. CONTRACTOR SHALL SUBMIT DOCUMENT
CONFIRMING THAT ALL PERSONNEL INSTALLING ANCHORS HAVE PASSED THE TRAINING
COURSE PRIOR TO THE COMMENCEMENT OF…
This is the start of the file's text. The full file is on GovTribe.