This is Addendum No. 2 to the bid documents for a roofing and window wind mitigation project at Delgado Community College's Westbank Campus in New Orleans, Louisiana, issued September 9, 2026. The project involves membrane roofing and window replacement in Building 1 and metal roofing and window replacement in Building 2 located at 2600 General Meyer Avenue. The scope encompasses SBS Modified Bituminous Membrane Roofing by SOPREMA, Inc., Standing Seam Metal Roof Panels by Metal Roofing Systems, Inc., and retrofit roof framing systems by Top Hat Enhanced Engineering. The mandatory pre-bid conference was held on August 28, 2026, with site tours available after the meeting and on August 31, 2026. Sealed bids were due September 16, 2026 at 2:00 p.m. CST. The project budget is approximately $3,000,000, with a project number of 40006-R0031505.

The addendum clarifies insurance requirements, increasing the Combined Single Limit of Insurance for projects in this value range from $2,000,000 to $3,000,000 for all applicable policies, including the Builders' Risk policy. The Owners' Protective Indemnity (OPI) limit equals the bid amount. Approved equal roofing products from SOPREMA, Inc. are specified with detailed material specifications including field plies, interply materials, and various flashing options. A pull test report dated August 22, 2025 (Report PT-21135) documents testing of the existing roof assembly on 24,844 square feet, performed on a steel deck with single-ply roofing. The test results show fastener pull values ranging from 523 to 821 pounds-force across twelve test locations using Siplast Parafast XHD and Parafast HD fasteners with 3/4-inch penetration.

View the file

Other files

File Type Posted
40006-R0031505-3.pdf PDF
40006-R0031505-1.pdf PDF
40006-R0031505.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Page-1

ADDENDUM NO. 2

TO THE BID DOCUMENTS FOR:

DELGADO COMMUNITY COLLEGE

WESTBANK, BUILDING 1 AND 2

ROOFING AND WINDOW WIND MITIGATION

2600 GENERAL MEYER AVE.

NEW ORLEANS, LOUISIANA 70119

PROJECT NO. 40006-R0031505

September 9, 2026

I. Scope:

1. Addendum No. 2 is issued in accordance with the provisions of the general specifications for the referenced project and is now considered to be an integral part of those original plans, specifications and contract documents.

2. ADDENDUM NO. 2 has been issued and shall also be posted and distributed by e-mail to Plan Holders of Record.

This addendum contains the following items:

General

Pre-Bid Meeting Minutes.

Pre-Bid Sign-In Sheet.

Clarifications to Specifications.

Approved Equals.

Requests for Information.

II. General:

Pre-Bid Meeting Minutes are attached to this Addendum.

Pre-Bid Meeting Sign-In Sheet is attached to this Addendum.

III. Clarifications to the Specifications:

Insurance:

Change the Combined Single Limit of Insurance for projects between a million dollars and ten million dollars on page S-15 from a minimum limit and aggregate of $2,000,000, to a minimum limit and aggregate of $3,000,000. This coincides with the amount listed in the front-end docs;

those limits are correct along with the building valuation which would put the combined single limit at $3,000,000. It would also apply to the Builders’ Risk policy which should be $3,000,000. OPI limit equals the bid amount.

ADDENDUM NO. 002

DELGADO COMMUNITY COLLEGE

Page-2

IV. Approved Equals

075500 SBS Modified Bituminous Membrane Roofing:

SOPREMA, Inc.:

Field Plies:

Cap Sheet: Sopralene 180 Granules FR; (160 mils/4.0 mm thick, weight 108 lbs per square; polyester reinforced).

Interply: Sopralene 180 sanded 2.2, polyester reinforced (90 mils/2.2 mm thick, 58 lbs.

per square).

Mopped Granular Flashing Plies:

Cap Ply: Sopralene 180 Granules FR; (160 mils/4.0 mm thick, weight 108 lbs. per square; polyester reinforced).

Stripping Ply: Sopralene 180 sanded 2.2, polyester reinforced (90 mils/2.2 mm thick, 58 lbs. per square).

Heat Fused Granular Flashing Plies:

Cap Ply: Sopralene Flam 180 FR GR; (157 mils/4.0mm thick, weight 118 lbs. per one square roll; with a non-woven polyester mat) Stripping Ply: Sopralene Flam 180; (118 mils/3.0mm thick, weight 81 lbs. per one square roll; with a non-woven polyester mat)

Heat Fused Aluminum Clad Flashing Plies:

Cap Ply: Sopralast TV Aluminum, fiberglass reinforced (162 mils/4.2 mm thick, 97 lbs per square), torch applied.

Stripping Ply: Sopralene Flam 180

Cold Adhesive: Colply

074113.16 Standing Seam Metal Roof Panels:

Metal Roofing Systems, Inc.:

MRS System 3000

051650 Retrofit Roof Framing Systems

Top Hat Enhanced Engineering:

Zee-Strip Retrofit Sub Frame including all optional system components required to meet wind uplift parameters.

V. Requests for Information

The pull test and pictures of the roofing core performed on the existing flat roofs are attached for Contractor’s General Information.

End of Addendum No. 2

Meeting Minutes

MichaelBuisson Rectangle

What is the budget? Approximately $3,000,000

Can we visit the site again? The buildings will be open after this meeting and again on Monday, August 31, 2026 for Contractors to tour.

1 | Delgado West Bank PT-21135

PULL TEST REPORT

JOB NAME Delgado West Bank REPORT NUMBER PT-21135

JOB LOCATION New Orleans, LA TEST DATE / TIME 8/22/2025 10:30:00 AM

ROOF AREA (SQFT) 24,844 AMBIENT TEMPERATURE 90°F

BUILDING HEIGHT (FT) 20’ TESTER MANUFACTURER DMD Force-2000

PROJECT TYPE Re-roof MAX CAP OF TESTER

(LBS)

2,000

THICKNESS OF EXISTING

ROOF ASSEMBLY

3-7” TEST PERFORMED BY Koy Kresta

ROOF COVER TYPE M/A Single Ply TEST CUT AREA

REPAIRED BY

Brian

NEW SYSTEM

MANUFACTURER

Siplast TEST WITNESSED BY Michael Buisson, Brian

FASTENER(S) TESTED Parafast XHD, Parafast HD

INSULATION MANUFACTURER INSULATION TYPE THICKNESS

Siplast Unknown Unknown

DECK TYPE THICKNESS

Steel Unknown

Disclaimer: Manufacturer’s installation requirements shall be followed when using any of the tested fasteners or adhesives.

Neither the technician performing the pullout tests, nor his/her company is responsible for the waterproofing integrity of the repairs. This test report does not certify the structural integrity of the roof deck.

2 | Delgado West Bank PT-21135

TEST RESULTS

TEST LOCATION

NUMBER

PULL VALUE

(LBF) FASTENER TESTED

PENETRATION

(IN)

BIT DIAMETER

(IN) COMMENTS

1 523 Siplast Parafast XHD 3/4”

2 704 Siplast Parafast HD 3/4”

3 534 Siplast Parafast XHD 3/4”

4 812 Siplast Parafast HD 3/4”

5 644 Siplast Parafast XHD 3/4”

6 562 Siplast Parafast HD 3/4”

7 621 Siplast Parafast XHD 3/4”

8 676 Siplast Parafast HD 3/4”

9 821 Siplast Parafast XHD 3/4”

10 730 Siplast Parafast HD 3/4”

11 523 Siplast Parafast XHD 3/4”

12 567 Siplast Parafast HD 3/4”

3 | Delgado West Bank PT-21135

ROOF IMAGE/DIAGRAM

DELGADO WEST BANK

4 | Delgado West Bank PT-21135

END OF REPORT