These are construction drawings for the Repair Launch Facility Concrete project at Malmstrom Air Force Base in Montana, dated February 13, 2025, under project number NZAS 22-6000. The drawings are issued by Global Strike Command and consist of three sheets: a cover sheet with location maps and sheet index, a typical site layout showing facility access points (north, south, east, and west access), and a demo and repair plan identifying concrete areas requiring work.
The demo and repair plan indicates the scope includes removal and replacement of concrete surfaces throughout the launch facility, with existing joints, bearing surfaces, and typical base plate grout areas marked for reference. Key contractor responsibilities outlined in the drawings include obtaining necessary permits, maintaining compliance with state and federal erosion control requirements, restoring all damaged drainage ditches to original condition, protecting surrounding concrete and adjacent surfaces from damage during construction, and ensuring all materials are installed per manufacturer specifications with prior written approval from the contracting officer. At minimum, one traffic lane must be maintained at all times to allow vehicle access to the site, and the contractor is responsible for providing utilities. The drawings serve as technical specifications for the concrete repair work required at this military installation.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 10_LF Concrete Q and A.pdf | ||
| 1_Specs.pdf | ||
| 7_Section L and M.pdf | ||
| 2_Submittal Schedule.pdf | ||
| 8_Past Performance Reference Sheet.pdf | ||
| 9_Subcontractor Consent.pdf | ||
| Solicitation - FA462626R0013.pdf | ||
| 5_WD MT20260077 (17May26).pdf | ||
| 3_Schedule of Drawings.pdf | ||
| 6_LF Concrete Bid Schedule.xlsx | XLSX spreadsheet |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
M O N T A N A
CONSTRUCTION DRAWINGS
REPAIR LAUNCH FACILITY CONCRETE
Malmstrom AFB, MT 59402
DATE 02/13/2025
NZAS 22-6000
SHEET INDEX
NOTES:
GLOBAL STRIKE COMMAND
MALMSTROM AIR FORCE BASE, MONTANA
AutoCAD SHX Text
1. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY NECESSARY PERMITS. 2. THE CONTRACTOR SHALL BE RESPONSIBLE FOR COMPLIANCE THE CONTRACTOR SHALL BE RESPONSIBLE FOR COMPLIANCE WITH STATE AND/OR FEDERAL EROSION CONTROL REQUIREMENTS. 3. ALL DRAINAGE DITCHES AFFECTED BY CONSTRUCTION SHALL ALL DRAINAGE DITCHES AFFECTED BY CONSTRUCTION SHALL BE RESTORED TO ORIGINAL CONDITION, UNLESS OTHERWISE NOTED ON PLANS.
AutoCAD SHX Text
MISSOULA
AutoCAD SHX Text
KALISPELL
AutoCAD SHX Text
HELENA
AutoCAD SHX Text
CASCADE
AutoCAD SHX Text
CONRAD
AutoCAD SHX Text
SHELBY
AutoCAD SHX Text
FORT
AutoCAD SHX Text
BENTON
AutoCAD SHX Text
GREAT FALLS
AutoCAD SHX Text
HAVRE
AutoCAD SHX Text
LEWISTOWN
AutoCAD SHX Text
SHEET NUMBER
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
COVER SHEET, LOCATION MAPS & SHEET INDEX
AutoCAD SHX Text
TYPICAL SITE LAYOUT
AutoCAD SHX Text
DEMO AND REPAIR PLAN
AutoCAD SHX Text
AutoCAD SHX Text
ROY
AutoCAD SHX Text
FA4626-24-X-XXXX
AutoCAD SHX Text
REV.
AutoCAD SHX Text
DATE
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
DRAWN
AutoCAD SHX Text
APPR'D
AutoCAD SHX Text
DRAWN BY
AutoCAD SHX Text
DESIGNED BY
AutoCAD SHX Text
REVIEWED BY
AutoCAD SHX Text
SCALE
AutoCAD SHX Text
DATE
AutoCAD SHX Text
PLATE
AutoCAD SHX Text
PAGE
AutoCAD SHX Text
OF
AutoCAD SHX Text
PROJECT NUMBERS
AutoCAD SHX Text
ACAD DRAWING NUMBER
AutoCAD SHX Text
RECORD FILE NUMBER
AutoCAD SHX Text
AS SHOWN
AutoCAD SHX Text
AutoCAD SHX Text
LAUNCH FACILITY CONCRETE REPAIR
AutoCAD SHX Text
NZAS 22-6000
AutoCAD SHX Text
AutoCAD SHX Text
JTS
AutoCAD SHX Text
COVER SHEET, LOCATION MAPS & SHEET INDEX
AutoCAD SHX Text
ATTACHMENT 4
AutoCAD SHX Text 2/18/2026
AutoCAD SHX Text
JTS
GLOBAL STRIKE COMMAND
MALMSTROM AIR FORCE BASE, MONTANA
Feet 0 10 20
AutoCAD SHX Text
TYPICAL SITE LAYOUT
AutoCAD SHX Text NOTES: 1. EACH SITE ONLY HAS ONE OF THE FOUR ACCESS EACH SITE ONLY HAS ONE OF THE FOUR ACCESS SHOWN IN THIS TYPICAL. 2. ANY STRUCTURES, UTILITIES, OR SITE SURFACES ANY STRUCTURES, UTILITIES, OR SITE SURFACES DAMAGED DURING CONSTRUCTION WILL NEED TO BE REPAIRED/REPLACED IN KIND BY THE CONTRACTOR. 3. AS A MINIMUM, ONE LANE OF TRAFFIC MUST BE AS A MINIMUM, ONE LANE OF TRAFFIC MUST BE MAINTAINED TO ALLOW VEHICLE ACCESS TO THE SITE AT ALL TIMES.
AutoCAD SHX Text
FA4626-24-X-XXXX
AutoCAD SHX Text
REV.
AutoCAD SHX Text
DATE
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
DRAWN
AutoCAD SHX Text
APPR'D
AutoCAD SHX Text
DRAWN BY
AutoCAD SHX Text
DESIGNED BY
AutoCAD SHX Text
REVIEWED BY
AutoCAD SHX Text
SCALE
AutoCAD SHX Text
DATE
AutoCAD SHX Text
PLATE
AutoCAD SHX Text
PAGE
AutoCAD SHX Text
OF
AutoCAD SHX Text
PROJECT NUMBERS
AutoCAD SHX Text
ACAD DRAWING NUMBER
AutoCAD SHX Text
RECORD FILE NUMBER
AutoCAD SHX Text
AS SHOWN
AutoCAD SHX Text
AutoCAD SHX Text
LAUNCH FACILITY CONCRETE REPAIR
AutoCAD SHX Text
NZAS 22-6000
AutoCAD SHX Text
AutoCAD SHX Text
JTS
AutoCAD SHX Text
TYPICAL SITE LAYOUT
AutoCAD SHX Text
ATTACHMENT 4
AutoCAD SHX Text 2/18/2026
AutoCAD SHX Text
JTS
AutoCAD SHX Text
SOUTH ACCESS
AutoCAD SHX Text
WEST ACCESS
AutoCAD SHX Text
NORTH ACCESS
EAST ACCESS
GLOBAL STRIKE COMMAND
MALMSTROM AIR FORCE BASE, MONTANA
Feet 0 5 10
AutoCAD SHX Text
CONCRETE AREAS
AutoCAD SHX Text
TYPICAL BASE PLATE GROUT AREAS
AutoCAD SHX Text
EXISTING JOINTS
AutoCAD SHX Text
BEARING SURFACE
AutoCAD SHX Text
FA4626-24-X-XXXX
AutoCAD SHX Text
REV.
AutoCAD SHX Text
DATE
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
DRAWN
AutoCAD SHX Text
APPR'D
AutoCAD SHX Text
DRAWN BY
AutoCAD SHX Text
DESIGNED BY
AutoCAD SHX Text
REVIEWED BY
AutoCAD SHX Text
SCALE
AutoCAD SHX Text
DATE
AutoCAD SHX Text
PLATE
AutoCAD SHX Text
PAGE
AutoCAD SHX Text
OF
AutoCAD SHX Text
PROJECT NUMBERS
AutoCAD SHX Text
ACAD DRAWING NUMBER
AutoCAD SHX Text
NZAS 22-6000
AutoCAD SHX Text
AutoCAD SHX Text
JTS
AutoCAD SHX Text
DEMO AND REPAIR PLAN
AutoCAD SHX Text
ATTACHMENT 4
AutoCAD SHX Text 2/18/2026
AutoCAD SHX Text
JTS
AutoCAD SHX Text
DEMO AND REPAIR PLAN
AutoCAD SHX Text NOTES: 1. CONTRACTOR TO PROVIDE OWN UTILITIES. CONTRACTOR TO PROVIDE OWN UTILITIES. 2. THE CONTRACTOR SHALL PROTECT ALL SURROUNDING THE CONTRACTOR SHALL PROTECT ALL SURROUNDING CONCRETE AND ADJACENT SURFACES FROM DAMAGE, STAINING, OR CONTAMINATION DURING REPAIR OPERATIONS. ANY MATERIAL SMEARED, SPILLED, OR DEPOSITED OUTSIDE THE REPAIR LIMITS SHALL BE REMOVED AND THE AFFECTED SURFACES RESTORED TO THEIR ORIGINAL CONDITION AT NO ADDITIONAL COST TO THE GOVERNMENT. 3. ALL MATERIALS SHALL BE INSTALLED, APPLIED, MIXED, AND ALL MATERIALS SHALL BE INSTALLED, APPLIED, MIXED, AND CURED IN STRICT ACCORDANCE WITH THE MANUFACTURER’S S RECOMMENDATIONS. THE CONTRACTOR SHALL OBTAIN AND FOLLOW THE MOST CURRENT INSTALLATION INSTRUCTIONS, INCLUDING REQUIREMENTS FOR SURFACE PREPARATION, ENVIRONMENTAL CONDITIONS, AND APPLICATION PROCEDURES. ANY DEVIATION FROM THE MANUFACTURER’S S RECOMMENDATIONS SHALL REQUIRE PRIOR WRITTEN APPROVAL FROM THE CONTRACTING OFFICER.
AutoCAD SHX Text
RECORD FILE NUMBER
AutoCAD SHX Text
AS SHOWN
AutoCAD SHX Text
LAUNCH FACILITY CONCRETE REPAIR
| Sheets and Views |
| Project Drawings 22-6000 65-Cover Sheet |
| Project Drawings 22-6000 65-TYPICAL SITE LAYOUT |
| Project Drawings 22-6000 65-Demo and Repair Plans |
File details come from the government source that posted it. Updated .