4-4. Planset AKA-22-OME IFC SCATTERED SITES PHASE II.pdf

PDF 16 MB Posted

Attached to
Nome - IFB ANTHC 25-B-391043 Residential Well & Septic Installations
Solicitation number
IFB ANTHC 25-B-391043
Issued by
Nome Census Area, Alaska

About this file

This is a construction plan set for scattered wastewater and water infrastructure improvements in Nome, Alaska, prepared by the Alaska Native Tribal Health Consortium's Division of Environmental Health and Engineering for the Jessica Blanford property. The project involves installing a new residential water and sewer system including a 1,500-gallon steel septic tank with lift station, pressure mound drainfield system with 64 infiltrator chambers, arctic water well with drainback or circulation system, insulated arctic pipe systems, and associated electrical controls. The comprehensive 37-sheet plan set includes detailed drawings for septic system schematics, arctic pipe fittings, well details, pressure systems, electrical components, and construction specifications for cold-climate installations requiring freeze protection measures.

The project addresses the challenging arctic construction environment with specialized components including 4-inch insulated arctic pipe carriers, heat trace systems, pressure tank details with drainback capabilities, and arctic service boxes designed for permafrost conditions. The plans specify extensive insulation requirements, including 4-inch rigid boardstock insulation over all septic system components and specialized arctic well caps and sleeves. Construction must comply with Alaska Department of Environmental Conservation regulations and incorporate anchoring systems for high groundwater conditions, with all installations requiring minimum 4-foot cover depths and specialized cold-weather materials and techniques throughout the system.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

NOME, ALASKA

SCATTERED SITES - PHASE II

ISSUED FOR CONSTRUCTION

PLAN SET NUMBER: AKA-22-OME

ANTHC PROJECT NUMBER: AKA-C6K.1276

RUSSIA

A L E U T I A N

OF

ANCHORAGE

BRISTOL BAY

CO

O K

IN

LE

T

NORTON SOUND

NOME

KOTZEBUE

JUNEAU

FAIRBANKS

CANADA

ARCTIC OCEAN

GULF

ALASKA

I S L A N D S

BERING SEA

CHUKCHI SEA

KODIAK

BETHEL

UNALASKA

Su si tn a

Koyukuk Yukon

Yu ko n

Ku sk ok wi m

River

River Rive r

River

Tanana

River

River

Kobuk

Colville Rive r

C op pe r

Rive r

River

ST. LAWRENCE

ISLAND

ST.

MATTHEW

ISLAND

NUNIVAK

ISLAND

PRIBILOF

ISLANDS

SEC 26, T11S, R34W, KATEEL

RIVER MERIDIAN

NOME

UTQIAGVIK

TOTAL SHEETSOFUSER: JEELLORIN PRODUCT: Autodesk Civil 3D 2023 - English FILE: P:\Nome\AKA-22-OME_Phase_II\CAD\Civil\OME-C-STLGND.dwg LAYOUT: COVR PRINTED: 5/1/2024 1:43:29 PM 1 37

ALASKA NATIVE

TRIBAL HEALTH

CONSORTIUM

DIVISION OF ENVIRONMENTAL

HEALTH AND ENGINEERING

4500 DIPLOMACY DRIVE

ANCHORAGE, ALASKA, 99508-3440

PHONE: (907) 729-3600

FAX: (907) 729-4090

http://www.dehe.org

SHEET LIST TABLE

SHEET # SHEET TITLE PG #

- COVER SHEET 1

C-001 COMMUNITY MAP 2

C-002 LEGEND AND DESIGN CRITERIA 3

C-101 JESSICA BLANFORD PLAT 4

C-102 JESSICA BLANDFORD SITE PLAN 5

C-103 JESSICA BLANDFORD DESIGN NOTES 6

C-104 JESSICA BLANDFORD DESIGN PLAN 7

SSSD-100 SEPTIC SYSTEM SCHEMATIC 8

SSSD-200 ARCTIC GRAVITY PIPE AND FITTINGS 9

SSSD-201 ARCTIC PRESSURE PIPE FITTINGS 10

SSSD-202 ARCTIC PIPE CONNECTIONS 11

SSSD-300 SEWER SERVICE AND CLEANOUT - ARCTIC PIPE 12

SSSD-304 SERVICE UTILITY BOX 13

SSSD-306 SERVICE UTILITY BOX SEWER HOUSE - BELOW FINISHED FLOOR 14

SSSD-400 SEWER SERVICE LINE TRENCH 15

SSSD-401 WATER SERVICE LINE TRENCH 16

SSSD-523 IM-1530 - 1500 GALLON SEPTIC TANK - ANCHORING SYSTEM 17

SSSD-545 STEEL SEPTIC TANK FROM ANC TANK AND LIFT STATION - PERMAFROST 18

SSSD-566 LIBERTY PUMP LIFT STATION 19

SSSD-567 ANCHORAGE SEPTIC TANK 20

SSSD-640 MOUND SYSTEM (ABOVE-GRADE) 21

SSSD-643 PRESSURE MOUND LATERAL ORIFICE SPACING 22

SSSD-700 ARCTIC BOX - WATER SERVICE CONNECTION 23

SSSD-701 ARCTIC BOX - WATER SERVICE CONNECTION 24

SSSD-730 ARCTIC DRAINBACK WELL WITH PRESSURE SYSTEM 25

SSSD-731 ARCTIC WELL DETAILS (DRAINBACK SYSTEM) 26

SSSD-740 CIRCULATING WELL WITH PRESSURE SYSTEM 27

SSSD-741 CIRCULATING WELL DETAILS 28

SSSD-781 CIRC PUMP FOR ARCTIC CIRCULATION LONG HEAT TRACE 29

SSSD-800 PRESSURE TANK DETAIL 30

SSSD-801 PRESSURE TANK DETAIL WITH DRAINBACK 31

SSSD-850 BOLLARD DETAIL 32

SSSD-900 ELECTRICAL LEGEND 33

SSSD-930 ELECTRICAL - ARCTIC WELL DETAILS 34

SSSD-940 ELECTRICAL - CIRCULATING WELL DETAILS 35

SSSD-951 ELECTRICAL SEWER SERVICE - LIFT STATION 36

SSSD-960 EFFLUENT PUMP CONTROL PANEL 37

http://anthc.org http://anthc.org http://anthc.org http://anthc.org http://anthc.org http://anthc.org http://anthc.org http://anthc.org http://anthc.org http://anthc.org http://www.dehe.org

SHEET OF

4500 Diplomacy Drive Anchorage, Alaska 99508

(907) 729-3600

D

A

B

C

1 2 3 4

M R

K D

AT

E

D

ES

C R

IP

TI

O N

PROJ MGR:

DRAWN BY:

DRUMS ENG:

PROJ ENG:

PLAN SET:

SHEET TITLE

Division of Environmental Health and Engineering

IN

IT

BAR IS ONE INCH ON

ORIGINAL DRAWING, IF NOT

ADJUST SCALES ACCORDINGLY

USER: MCYANDELL PRODUCT: Autodesk Civil 3D 2023 - English FILE: P:\Nome\AKA-22-OME_Phase_II\CAD\Civil\OME-C-STLGND.dwg LAYOUT: COMM PRINTED: 5/1/2024 11:32:54 AM

0 1"

TOTAL SHEETSOF

C-001 1 6

MY

ML

KS

AKA-22-OME

COMMUNITY MAP

N O

M E, A K

SC

A

TT

ER

ED

S

IT

ES

PH

A

SE

II

IS

SU

ED

F O

R C

O N

ST

R

U C

TI

O

N

49 THST

ATE OF ALASKA

REENIGN

ANOISSE L E

FORPDERETS

GE

R

I

KURT D. SAUERS

CE-10280

BESSIE RD JESSICA BLANFORD,

SEE SHEET C-104

BEAM RD

DE

XT

ER

B

YP

AS

S

B

EA

M R

D

BEAM R

D

OSBORNE RD

OSBORNE RDNO

M

E

TE

LL

ER

H W

Y

CE

NT

ER

CR

EE

K

RD

NOME

AIRPORT

NOME TELLER HWY

NORTON SOUND

05/01/2024

Anchorage, Alaska 99508

(907) 729-3600

D

A

B

C

1 2 3 4

M R

K D

AT

E

D

ES

C R

IP

TI

O N

PROJ MGR:

DRAWN BY:

DRUMS ENG:

PROJ ENG:

PLAN SET:

SHEET TITLE

Division of Environmental Health and Engineering

IN

IT

BAR IS ONE INCH ON

ORIGINAL DRAWING, IF NOT

ADJUST SCALES ACCORDINGLY

USER: MCYANDELL PRODUCT: Autodesk Civil 3D 2023 - English FILE: P:\Nome\AKA-22-OME_Phase_II\CAD\Civil\OME-C-STLGND.dwg LAYOUT: CRTR PRINTED: 5/1/2024 11:32:55 AM

0 1"

TOTAL SHEETSOF

C-002 2 6

MY

ML

KS

AKA-22-OME

LEGEND AND DESIGN

CRITERIA

N O

M E, A K

SC

A

TT

ER

ED

S

IT

ES

PH

A

SE

II

IS

SU

ED

F O

R C

O N

ST

R

U C

TI

O

N

49 THST

ATE OF ALASKA

REENIGN

ANOISSE L E

FORPDERETS

GE

R

I

KURT D. SAUERS

CE-10280

GENERAL DESIGN NOTES

1. GRAVITY WASTEWATER SERVICE LINE FROM HOUSE TO TANK SHALL BE

SET AT A MINIMUM OF 2% SLOPE. HOWEVER, THIS MAY BE A BIT STEEPER

AS SLOPE VARIES BASED ON LENGTH AND DISTANCE AND THE SLOPE

EQUALS RISE OVER RUN.

2. SEWER SERVICE LINES TO BE ABS; SEPTIC TANKS, DRAINFIELD, AND

REPS UNITS WILL NEED 4” OF RIGID BOARDSTOCK OVER THEM.

3. THERE SHALL BE A MINIMUM OF 4 FT OF COVER OVER PIPE, TANK, AND

DRAINFIELD TO PREVENT FREEZING.

4. PER DEC THE BOTTOM OF DRAINFIELD (GRAVEL BASE) MUST HAVE 4 FT

OF CLEARANCE TO GROUNDWATER AND 6 FT TO IMPERMEABLE LAYER.

5. A 100 FT SEPARATION DISTANCE MUST BE MAINTAINED BETWEEN THE

WELL AND SEPTIC TANK AND DRAINFIELD. INCLUDING 100 FT FROM

NEIGHBORING WELLS, LAKES, RIVERS, SLOUGHS, AND STREAMS.

6. THERE MUST BE 10 FT OF SEPARATION FROM THE SEPTIC SYSTEM TO

THE PROPERTY LINES.

7. THE DRAINFIELD MUST BE LOCATED GREATER THAN 50 FT AWAY FROM A

25% SLOPE.

GENERAL CONSTRUCTION NOTES:

1. CONTRACTOR MUST COMPLY WITH ALL OSHA TRENCHING

REQUIREMENTS, REFER TO SECTION 31 23 16.13, TRENCHING.

EXCAVATION LIMITS AND SLOPES SHOWN ARE 1:1 AND ASSUMED TO BE

TYPE B SOILS, BUT MUST BE VERIFIED BY CONTRACTOR. MOUND SYSTEM

FINISHED GRADE SLOPES SHOULD BE 3:1 FOR EASE OF MAINTENANCE.

2. GENERAL LANDSCAPING AND SITE CLEAN-UP - IN GENERAL, ALL

DISTURBED AREAS SHALL BE GRADED, COMPACTED, LEVELED, AND HAND

OR MACHINE RAKED. ROCKS LARGER THAN 3” SHOULD BE REMOVED

FROM THE SURFACE. ALL CONSTRUCTION DEBRIS, BRUSH, ROOT BALLS,

AND LIMBED TREE BRANCHES SHALL BE REMOVED FROM THE SITE.

BUCKED LOGS CAN BE NEATLY STACKED AND LEFT, IF HOMEOWNER

AGREES. ALL SEPTIC SYSTEM OBSERVATION PORTS SHALL BE VERTICAL

AND PLUMB, AND CAPPED, AND SHALL BE CLEANED OFF OF ALL MUD,

DIRT AND MARKINGS. ACCESS RISERS ON SEPTIC TANKS SHALL BE

SECURED AND BE CLEARED OF DIRT AND MUD. IF GRAVEL OR PAVED

DRIVEWAYS ARE IMPACTED THEY MUST BE REPLACED TO AN “OR

BETTER” STATUS.

3. THE GRAVEL/SEWER ROCK FOR THE DRAINFIELD MUST BE RAKED LOOSE

AND NOT COMPACTED BY EQUIPMENT.

4. THE BOARDSTOCK LAYER MUST BE LAID ONTO SMOOTH SOIL SURFACE

WITHOUT LARGE ROCKS OR VOIDS, AND CAPPED WITH CLEAN BACKFILL

WITHOUT LARGE ROCKS OR VOIDS.

5. CONSTRUCTION PHOTOS AND WORK LOGS MUST BE SUBMITTED DAILY,

AS WORK PROCEEDS.

6. THE SYSTEM MUST BE INSTALLED AS DESIGNED, AND ONLY CHANGED OR

RE-POSITIONED WITH APPROVAL OF THE ENGINEER.

7. UNDERGROUND UTILITIES MUST BE IDENTIFIED AND LOCATED PRIOR TO

EXCAVATION. PLEASE CALL ALASKA DIGLINE, INC AT 811, A MINIMUM OF

THREE WORKING DAYS PRIOR TO INSTALLATION OF THE SYSTEM.

8. ONCE LOCATED, UNDERGROUND UTILITIES MAY NEED TO BE PROTECTED

FROM DAMAGE DURING INSTALLATION.

9. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO NOT ENCROACH

OVER PROPERTY LINES.

10. SEWER ROCK AND COARSE FILTER SAND MUST MEET AK DEC

SPECIFICATIONS

11. THE CONTRACTOR IS RESPONSIBLE FOR LOCATING ALL BURIED UTILITIES,

EASEMENTS, PROPERTY LINES, RIGHT-OF-WAYS, SURFACE WATER

SET-BACKS, WELL RADIUS, AND WATER SERVICE LINES, THAT MAY

INTRUDE INTO THE DESIGN LAYOUT OF THE PROPOSED ON-SITE SEPTIC

SYSTEM.

12. ANY ENCROACHMENTS FOUND, THAT WERE NOT IDENTIFIED ON THE

ENGINEERING PLANS SHOULD BE BROUGHT TO THE ATTENTION OF THE

ENGINEER-OF-RECORD.

13. CONTRACTOR TO ESTABLISH SURVEY BENCHMARKS, FROM WHICH TO

ESTABLISH ELEVATIONS. THE ON-SITE SEPTIC SYSTEM HAS BEEN

DESIGNED USING ELEVATIONS.

14. SITE INSPECTIONS - THE CONTRACTOR MUST NOTIFY THE PROJECT

MANAGER AND ENGINEER AT LEAST 24 HRS PRIOR TO BEGINNING

CONSTRUCTION. INSPECTIONS SHOULD TAKE PLACE DURING NORMAL

BUSINESS HOURS.

a. THE FOLLOWING ARE INSPECTION POINTS THAT MUST BE PHOTO

DOCUMENTED BY THE CONTRACTOR.

i. INITIAL BEFORE PHOTOS OF THE SITE, PRIOR TO THE START OF

CONSTRUCTION

ii. THE BOTTOM OF ALL TRENCHES

iii. THE BOTTOM /BEDDING OF THE SEPTIC TANK AND PUMP CHAMBERS iv.THE BOTTOM OF THE PRESSURE MOUND DRAINFIELD

v. TOP OF SAND LINER OF PRESSURE MOUND DRAINFIELD vi.TOP OF SEWER ROCK OF PRESSURE MOUND DRAINFIELD

vii. LAYOUT OF PERFORATED DISTRIBUTION MANIFOLD AND DRAINFIELD

CHAMBERS

viii. BOARDSTOCK COVERING OF BED SYSTEM ix.GEO-FABRIC COVERING OF BED SYSTEM

x. TOP OF SEPTIC TANK, RISERS, AND PUMP CHAMBERS xi.CONTROL AND ALARM PANEL KIOSK, INTERIOR OF PANELS, AND

EXTERIOR

xii. SEWER SERVICE LINE AND CLEAN-OUT

xiii. SEWER SERVICE LINE HOUSE PENETRATION OF CONNECTION POINT

xiv. FINAL GRADING AND FINISHED GRADE OF SEPTIC SYSTEM FROM

MULTIPLE ANGLES

15. THE CONTRACTOR SHALL PROVIDE ANTHC OPERATION AND

MAINTENANCE MATERIALS, AND ANY COPIES OF MANUFACTURER'S

LITERATURE OF THE SYSTEM COMPONENTS. ANTHC WILL COMPILE THE

O&M MANUAL FOR THE HOMEOWNER.

REFERENCES

· STATE OF ALASKA ADEC ONSITE WASTEWATER SYSTEM INSTALLERS

MANUAL, JANUARY 2016

· ONSITE WASTEWATER TREATMENT SYSTEMS: SOIL AND SITE EVALUATIONS,

DESIGN, CONSTRUCTION AND MAINTENANCE, TYLER AND ASSOCIATES, INC.

· WISCONSIN MOUND SOIL ABSORPTION SYSTEMS: SITING, DESIGN, AND

CONSTRUCTION MANUAL, JC CONVERSE AND EJ TYLER, JANUARY 2000

· PRESSURE DISTRIBUTION NETWORK DESIGN, JC CONVERSE, JANUARY 2000

· WASHINGTON STATE DEPT. OF HEALTH, PRESSURE DISTRIBUTION

SYSTEMS, 2012

· ADEC WASTEWATER DISPOSAL REGULATIONS 18AAC72, NOVEMBER 2017

· ANTHC TECHNICAL SPECIFICATIONS - 2021

DEC DESIGN LOADING CRITERIA I

DESCRIPTION DESIGN LOADING

GW

WELL GRADED GRAVEL, FASTER THAN 1 MIN/IN;

ADD 2' OF COARSE FILTER SAND UNDER

DRAINFIELD, WHEN PERC RATE IS FASTER THAN 1

MIN/IN

150 SF/BR

GW WELL GRADED GRAVEL, SLOWER THAN 1 MIN/IN 125 SF BR

GP

POORLY GRADED GRAVEL, FASTER THAN 1 MIN/IN;

ADD 2' OF COARSE FILTER SAND UNDER

DRAINFIELD, WHEN PERC RATE IS FASTER THAN 1

MIN/IN

150 SF BR

GP POORLY GRADED GRAVEL, SLOWER THAN 1 MIN/IN 125 SF BR

SW WELL GRADED SAND 150 SF BR

SP POORLY GRADED SAND 150 SF BR

GM SILTY GRAVEL PERC TEST

SM SILTY SAND PERC TEST

ML SILT PERC TEST

DEC DESIGN LOADING CRITERIA II

PERC TEST DESIGN LOADING

1-5 MIN / IN 125 SF BR

6-15 MIN / IN 190 SF BR

16 - 30 MIN / IN 250 SF BR

31 - 60 MIN / IN 335 SF BR

61-120 MIN / IN ENGINEER

120 AND GREATER NOPE

SEPTIC TANK SIZING

@ BEDROOMS MIN SIZE

1-3 1,000 GAL

4 1,250 GAL

5 1,500 GAL

6 1,750 GAL

7 2,000 GAL

8 2,250 GAL

GENERAL NOTES:

THESE DRAWINGS HAVE BEEN DEVELOPED FOR CONSTRUCTION BY

CONSTRUCTION CONTRACT METHODOLOGY. CONSTRUCTION SPECIFICATIONS

HAVE ALSO BEEN DEVELOPED SPECIFICALLY FOR THIS PROJECT. TOGETHER,

THE DRAWINGS AND CONSTRUCTION SPECIFICATIONS CONSTITUTE A

COMPLETE AND INSEPARABLE SET OF CONSTRUCTION DOCUMENTS, INCLUDING

ALL NECESSARY CONSTRUCTION AND MATERIALS SPECIFICATIONS TO ENSURE

THE PROJECT AS CONSTRUCTED MEETS THE DESIGN INTENT. ANY CHANGES

TO CONSTRUCTION METHODS OR MATERIALS SHALL BE APPROVED IN ADVANCE

BY THE RESPONSIBLE REGISTERED PROFESSIONAL.

REGARDING BRAND NAMES IN ENGINEERING DRAWINGS AND TECHNICAL

SPECIFICATIONS. WHILE SPECIFIC BRANDS ARE LISTED BASED ON AVAILABILITY

AND MEETING CERTAIN CRITERIA, ALTERNATIVES CAN BE CONSIDERED.

HOWEVER, ANY SUBSTITUTIONS MUST UNDERGO REVIEW BY THE ENGINEER-OF

RECORD TO ENSURE THEY MEET PROJECT REQUIREMENTS AND DESIGN

INTENT.

SITE STRUCTURES

WATER

POWER AND COMMUNICATION

ELECTRIC METER

SANITARY SEWER

TOPO AND VEGETATION

WATER WELL

SEWER MANHOLE

CLEANOUT

SEPTIC VENT

SEWER LIFT STATION

SEPTIC TANK

ARCTIC BOX

POWER POLE

ANTENNA

BOLLARD

CULVERT

FUEL TANK

PROPANE TANK

GATE POST

TEST HOLE

WATER

SANITARY SEWER

SITE

WATER MAIN

WATER SERVICE

GRAVITY SEWER MAIN

SEWER SERVICE

SEWER FORCE MAIN

FENCE LINE

W

A

CO

L

S

V

EM

ST

AB

B

FT

G

PT

TH

DRAINAGE CHANNEL

WATER ELEVATION

SILT FENCE LINE

X

O

W

WS

W

SS

FM

SITE PLAN LEGEND

BUILDING SERVED THIS PLANSET

RESTRICTED LOT

BURIAL GROUND, GRAVES

OR CEMETERY

RUINS

WETLANDS - MARSH - SWAMP

DRIVEWAY - MINOR ROAD - PATH

BUILDING NOT SERVED THIS PLANSET

OCEAN - LAKE - POND

SOIL - EXCAVATION

SOIL - FILL

05/01/2024

Anchorage, Alaska 99508

(907) 729-3600

D

A

B

C

1 2 3 4

M R

K D

AT

E

D

ES

C R

IP

TI

O N

PROJ MGR:

DRAWN BY:

DRUMS ENG:

PROJ ENG:

PLAN SET:

SHEET TITLE

Division of Environmental Health and Engineering

IN

IT

BAR IS ONE INCH ON

ORIGINAL DRAWING, IF NOT

ADJUST SCALES ACCORDINGLY

USER: MCYANDELL PRODUCT: Autodesk Civil 3D 2023 - English FILE: P:\Nome\AKA-22-OME_Phase_II\CAD\Civil\OME-C-STSITE_JBlandford.dwg LAYOUT: PLAT PRINTED: 5/1/2024 11:32:57 AM

0 1"

TOTAL SHEETSOF

C-101 3 6

MY

ML

KS

AKA-22-OME

JESSICA BLANFORD

PLAT

N O

M E, A K

SC

A

TT

ER

ED

S

IT

ES

PH

A

SE

II

IS

SU

ED

F O

R C

O N

ST

R

U C

TI

O

N

49 THST

ATE OF ALASKA

REENIGN

ANOISSE L E

FORPDERETS

GE

R

I

KURT D. SAUERS

CE-10280

JESSICA AND JESS BLANFORD -

LOT4, BLOCK 6 DEXTER TOWNSITE

05/01/2024

W S

W S

SP

OH/E

OH/E

OH/E

OH/E

OH/E

OH/E

OH/E

OH/E

OH/E

OH/E

OH/E

OH/E

OH/E

OH/E

OH/E

OH/E

OH/E

OH/E

OH/E

OH/E

OH/E

OH/E

FT

S S

S

S S

S S

FT

EM

ST

ST

CO

C

W

A

W

N77°59'37"W

190.00'

N

°0 0'

"E

4.

N77°59'36"W

190.00' N

°0

0'

"E

5.

TH

W

B

B

56'

54'

53'

54'

53'

WS

WS

WS

WS

AB

TH

60'

AB

SITE PLANA1 1" = 20'

MILE 8.5 KOUGARAK ROAD NOME, AK 99762

LOT 4 BLK 5 DEXTER TOWNSITE PLAT 83-14 CAPE NOME R.D.

LAT: 64°35'2.73"N LONG: 165°16'12.03"W; 46,609.2 SF (±1.07 AC)

SHEET OF

4500 Diplomacy Drive

B

C

1 2 3 4

M R

K D

AT

E

D

ES

C R

IP

TI

O N

PROJ MGR:

DRAWN BY:

DRUMS ENG:

PROJ ENG:

PLAN SET:

SHEET TITLE

Division of Environmental Health and Engineering

IN

IT

BAR IS ONE INCH ON

ORIGINAL DRAWING, IF NOT

ADJUST SCALES ACCORDINGLY

USER: MCYANDELL PRODUCT: Autodesk Civil 3D 2023 - English FILE: P:\Nome\AKA-22-OME_Phase_II\CAD\Civil\OME-C-STSITE_JBlandford.dwg LAYOUT: SITE PRINTED: 5/1/2024 3:12:35 PM

0 1"

TOTAL SHEETSOF

C-102 4 6

MY

ML

KS

AKA-22-OME

JESSICA BLANDFORD

SITE PLAN

N O

M E, A K

SC

A

TT

ER

ED

S

IT

ES

PH

A

SE

II

IS

SU

ED

F O

R C

O N

ST

R

U C

TI

O

N

0 20' 40'10'

49 THST

ATE OF ALASKA

REENIGN

ANOISSE L E

FORPDERETS

GE

R

I

KURT D. SAUERS

CE-10280

SCOPE OF WORK

WATER

· DRILL NEW RESIDENTIAL ARCTIC WATER WELL.

· THE WELL WILL BE EITHER AN ARCTIC DRAIN-BACK SYSTEM OR IT WILL BE A

CIRCULATING WELL, WITH CIRCULATING WATER SERVICE LINES AND DROP

PIPES. THIS DEPENDS ON THE DEPTH OF PERMAFROST ENCOUNTERED.

· INSTALL NEW WELL PUMP, DROP PIPE, PITLESS ADAPTER, AND PRESSURE

SYSTEM.

§ PRESSURE SYSTEM TO BE INSTALLED INSIDE HOUSE.

· INSTALL NEW INSULATED WATER SERVICE LINE, TO CONNECT THE WELL TO

THE HOUSE (40FT). WATER LINE IS 1” PEX OR HDPE PIPE, INSIDE A 4”X12”

ARCTIC PIPE CARRIER PIPE, WITH 4” OF BOARDSTOCK INSULATION OVER

PIPE.

· INSTALL LONG RUN HEAT TRACE WITH TIMERS AND CONTROLS. HEAT

TRACE TO RUN ALONG SERVICE LINE, AND DOWN WELL CASING TO BELOW

WELL PUMP.

· INSTALL SHORT RUN HEAT TRACE IN UTILIDOR AND ARCTIC BOX WITH

TIMERS AND CONTROLS

· INSTALL NEW ARCTIC BOX AND INSULATED UTILIDOR TO CONNECT WATER

LINE TO THE HOUSE, FROM THE BACK OF THE ARCTIC BOX TO THE FLOOR

PENETRATION.

· THE WELL NEEDS TO BE OPERATED TO ENSURE THAT THE SYSTEM IS

FULLY FUNCTIONAL. THE WELL CANNOT BE CONNECTED TO HOUSE

PLUMBING UNTIL AFTER THE WATER ANALYSIS SHOWS THAT THE WATER IS

SAFE TO DRINK. WATER TREATMENT EQUIPMENT MAY BE NEEDED TO BE

INSTALLED TO ACHIEVE THIS.

· OBTAIN A RAW WATER SAMPLE FOR BACTERIA AND THE LIST OF

CONTAMINANTS OUTLINED IN THE TECHNICAL SPECIFICATIONS,

APPROXIMATELY 35 ANALYTES.

· PROVIDE FINAL LANDSCAPING OVER WATER SERVICE LINE. COMPACT,

LEVEL, GRASS SEED AND FERTILIZE AREA. MOUND UP OVER SERVICE LINE

TO COMPENSATE FOR SETTLEMENT. ENSURE SURFACE WATER DRAINAGE

DOES NOT FLOW TOWARD HOUSE OR STRUCTURES ON PROPERTY.

SEWER

· INSTALL NEW SEPTIC TANK AND LIFT STATION AND A PRESSURE DOSING

MOUND DRAINFIELD.

· INSTALL NEW ARCTIC BOX AND INSULATED UTILIDOR IN CRAWLSPACE TO

CONNECT TO EXISTING SEWER SERVICE LINE AND HOUSE PLUMBING.

· INSTALL NEW INSULATED SEWER SERVICE LINE, 4”X12” INSULATED ARCTIC

PIPE, WITH 4” OF BOARDSTOCK INSULATION OVER PIPE, FROM THE HOUSE

TO THE SEPTIC TANK (30FT). THIS GRAVITY PIPE WILL NEED A HEAT TRACE

CHANNEL.

· INSTALL NEW 1,500 GALLON, EPOXY-COATED STEEL SEPTIC TANK FROM

ANCHORAGE TANK, WITH 4” OF BOARDSTOCK INSULATION OVER AND

AROUND SEPTIC TANK. NO INSULATION IS NEEDED UNDER TANK, UNLESS

PERMAFROST IS ENCOUNTERED. HIGH FLOWING GROUNDWATER TO BE

PUMPED FOR EXCAVATION AND INSTALLATION OF TANK. SEPTIC TANK TO

BE ANCHORED DUE TO HIGH GROUNDWATER.

· INSTALL NEW RESIDENTIAL EFFLUENT PUMPING STATION (REPS) UNIT

§ PROVIDE A 3/4 HP SUBMERSIBLE SEWAGE (EFFLUENT) PUMP CAPABLE

OF DELIVERING

§ 43 GPM @ 53 FT OF HEAD. (LIBERTY EFFLUENT PUMP, FL70 SERIES,

MODEL # FL72M-2, 2” DISCHARGE, WITH WEATHERPROOF CONTROL

PANEL ON KIOSK)

§ LIFT STATION BASIN TO BE A LIBERTY FIBERGLASS BASIN, 36”

DIAMETER X 11FT TALL.

· INSTALL NEW 2” HDPE PRESSURE FORCE MAIN INSIDE A 4”X12” INSULATED

ARCTIC PIPE CARRIER PIPE, WITH 4” OF BOARDSTOCK INSULATION OVER

PIPE, FROM THE LIFT STATION TO THE PRESSURE MOUND DRAINFIELD

(30FT).

· INSTALL 3 IMMERSION HEATERS, 2 IN THE SEPTIC TANK AND 1 IN THE LIFT

STATION.

· HEAT TRACE WILL BE RUN ON THE SEWER LINE, FROM THE ARCTIC BOX, TO

THE SEPTIC TANK AND LIFT STATION, TO THE FORCE MAIN GOING TO THE

MOUND DRAINFIELD.

· INSTALL NEW PRESSURE DOSING EFFLUENT MOUND DRAINFIELD.

§ THE MOUND CONSISTS OF 16 ROWS OF 4 CHAMBERS, FOR A TOTAL OF

64 CHAMBERS AND 724 SQ FT OF TREATMENT AREA. THE PERFORATED

PIPING IS PLACED UNDER DRAINFIELD CHAMBERS, THE CHAMBERS ARE

COVERED WITH GEOTEXTILE FABRIC AND 4” OF BOARDSTOCK

INSULATION. THERE IS 2FT OF DEC APPROVED SEWER ROCK UNDER

THE CHAMBERS AND 4FT OF DEC APPROVED COARSE-GRADED FILTER

SAND, BETWEEN THE GROUNDWATER TABLE AND THE BOTTOM OF THE

SEWER ROCK. FROM TEST HOLES, THE GROUNDWATER IS ESTIMATED

TO BE 3FT BELOW GRADE, AND THERE NEEDS TO BE A 4FT SEPARATE

BETWEEN GROUNDWATER AND BOTTOM OF THE SEWER ROCK (FILTER

SAND CAN BE WITHIN THIS DISTANCE).

· FINAL LANDSCAPING: COMPACT, LEVEL, GRASS SEED, AND FERTILIZE AREA.

CLEAN UP SITE. ENSURE DRAINAGE DOES NOT POOL UP ALONG SEPTIC

SYSTEM. MOUND-OVER SERVICE LINE, SEPTIC TANK, REPS UNIT, AND

MOUND DRAINFIELD SYSTEM TO COMPENSATE FOR SETTLEMENT. ENSURE

DRAINAGE DOES NOT POOL UP ANYWHERE NOR RUN TOWARD THE HOUSE

OR STRUCTURES ON PROPERTY.

· INSTALL A DRAINAGE SWALE BETWEEN THE HOUSE AND THE DRAINFIELD

MOUND TO DIRECT WATER TO THE WEST AND SOUTH OF THE HOUSE.

100' EXISTING

WELL RADIUS

RED FOX ROAD

TEST HOLE

TEST HOLE

100.00'

OFFSET TO LAKE

LOT 4 LOT 5

LOT 3

WETLAND

AREA

100' NEW WELL RADIUS

PLAN AND PROFILE,

SEE SHEET C-104

05/01/2024

BOH @ 12'

GROUNDWATER SEEPS AT 10FT

NO IMPERMEABLE LAYER

ENCOUNTERED

ABSORPTION FIELD DESIGN CRITERIA

· 5 BEDROOM HOUSE

· DESIGN FLOW RATE: 150 GAL/DAY/BEDROOM

· TOTAL DESIGN FLOW: 750 GAL/DAY

· TEST HOLE #1 - GROUNDWATER AT 3FT BG

· TEST HOLE #2 - SOIL TYPE @ 4FT IS: WELL-GRADED GRAVEL W/ SAND -

USCS CLASSIFICATION: GW

· TEST HOLE #2 - SOIL TYPE @ 8FT IS: WELL-GRADED GRAVEL W/ SAND -

USCS CLASSIFICATION: GW

· GROUNDWATER ENCOUNTERED AT 3FT - AT BOTH HOLES

· ELEVATION OF EXISTING GROUND AT TEST HOLE: 55 FT ASL (ABOVE SEA

LEVEL)

· THE PERCOLATION TEST WAS NOT PERFORMED DUE TO HIGH

GROUNDWATER

· GW SOILS ARE EITHER 125 SF/BEDROOM OR 150 SF/BEDROOM BASED ON

THE PERCOLATION RATE. ASSUME WORSE CASE SCENARIO AND USE 150

SF/BEDROOM AND ADD 2' SAND LINER

· IN ORDER TO PROVIDE 4FT SEPARATION TO GROUNDWATER, A

RESIDENTIAL EFFLUENT PUMPING STATION (REPS) OR LIFT STATION WILL

BE REQUIRED

· DESIGN WILL BE AN ABOVE-GRADE PRESSURE DISTRIBUTION MOUND

DRAINFIELD

· THE SYSTEM WILL HAVE 2FT OF 3” MINUS, DEC APPROVED, SEWER ROCK

· IT WILL INCLUDE 4FT OF DEC APPROVED COARSE-GRADED FILTER SAND -

DUE TO HIGH GROUNDWATER AND GW SOILS WITHOUT PERC TEST. NEED

TO MAKE UP FILL TO GET 4FT SEPARATION DISTANCE, AND GW 3FT BG

· THE PRESSURE DISTRIBUTION PIPING WILL BE PROTECTED WITH THE USE

OF INFILTRATOR CHAMBERS, THAT WILL PROTECT THE DISCHARGE PIPING

FROM CLOGGING AND PROVIDE VOID SPACE THAT CAN HANDLE SEVERE

PEAK FLOW EVENTS, AND HELPS WITH THE DISTRIBUTION OF THE

WASTEWATER.

· INFILTRATION AREA REQUIRED = 5 BEDROOMS * 150 SQ FT /BEDROOM =

750 SQ FT

· CHAMBER AREA PER UNIT IS: 2.83FT X 4FT LONG = 11.32 SQ FT/CHAMBER

· # OF CHAMBERS REQUIRED IS = 750 SQ FT / 11.32 SQ FT/CHAMBER = 66

CHAMBERS

· USE 64 CHAMBERS WITH 16 ROWS OF 4 CHAMBERS PER ROW (724 SQ FT)

· FINAL LOADING RATE IS: 750 GAL/DAY / 724 SQ FT = 1.04 GAL/DAY/SQ FT

· 1.04 GAL/DAY/SQ FT IS CLOSE TO THE E.J. TYLER RECOMMENDED LOADING

RATE OF 0.8 GAL/DAY/SQ FT FOR COARSE SAND WITH A BOD5 LOADING

RATE GREATER THAN 30MG/L WASTEWATER STRENGTH. HOWEVER, THE

ACTUAL FOOTPRINT OF THE SEWER ROCK WILL BE 24' x 49' = 1,078 SQ FT

FOR A FINAL INFILTRATION RATE OF 750 GAL/DAY / 1,078 SF = 0.70

GAL/DAY/SQ FT. (AN ACCEPTABLE LOADING RATE)

· SEPTIC TANK SIZING: DEC REQUIREMENT FOR 5 BEDROOM HOME IS A

1,500 GAL SEPTIC TANK. USE A 1,500 GALLON INSULATED EPOXY COATED

STEEL SEPTIC TANK FROM ANCHORAGE TANK

· THE SEPTIC TANK WILL NEED TO BE ANCHORED IN THE GROUNDWATER.

· THE PUMP CHAMBER WILL BE A SEPARATE PUMP BASIN, USE LIBERTY

EFFLUENT PUMP BASIN, 36” DIAMETER X 11FT LONG. (DUE TO HIGH

GROUNDWATER)

DESIGN OF PRESSURE DISTRIBUTION LATERALS AND PUMP DESIGN

· USE 2”, SDR 11, HDPE PRESSURE SEWER FORCE MAIN, RUN INSIDE A 4” X

12” ARCTIC PIPE CARRIER PIPE, FROM THE LIFT STATION TO THE HEADER

ASSEMBLY OF THE PRESSURE MOUND DRAINFIELD (12FT).

· TRANSITION TO 1½” SCH 40 PVC FOR HEADER AND DISTRIBUTION

LATERALS (300FT)

· THERE ARE 16 LATERALS OF 4 CHAMBERS

· THERE ARE 64 CHAMBERS (@11.32SQ FT/CHAMBER = 724 SQ FT)

· USE ¼” CLEAN DRILLED HOLES EVERY 24”, POINTED DOWNWARD

(6-O'CLOCK) AND HUNG UNDER THE CHAMBER. THE SYSTEM NEEDS TO

DRAIN AND DRAINBACK TO THE PUMP CHAMBER FOR FREEZE

PROTECTION.

· THERE ARE 2 HOLES PER CHAMBER OR 128 HOLES TOTAL, AND/OR 8

ORIFICES PER LATERAL WITH 16 LATERALS.

· ONE UPWARD FACING ¼” ORIFICE WILL NEED TO DRILLED AT THE END OF

EACH LATERAL, TO ALLOW AIR INTO THE SYSTEM AND THE LATERALS TO

FULLY DRAIN.

· EACH HOLE WILL COVER/PROVIDE: 724 SQ FT / 128 HOLES = 5.7 SQ FT PER

ORIFICE OF APPLICATION

· E. J. TYLER RECOMMENDS ABOUT A MAXIMUM TREATMENT AREA OF 6 SQ

FT PER ORIFICE, SO OKAY.

· THEY RECOMMEND A LATERAL DISTAL PRESSURE OF 2.5FT OF HEAD

PRESSURE AT END OF LATERAL (OR ABOUT 1.1PSI)

· PER E.J. TYLER, TABLE A-1 DISCHARGE RATE FOR ORIFICES, ¼” ORIFICE @

2.5' DISTAL PRESSURE = 1.17 GPM PER ORIFICE

· IDEAL FLOW RATE TO MAINTAIN PRESSURE AT FAR END OF DISTRIBUTION

SYSTEM = 1.17 GPM * 128 ORIFICES = 150 GPM

· STATIC ELEVATION HEAD = 10 FT

· ASSUMED HEADLOSS = 43 FT (300FT @ 14.3FT PER 100FT OF 1.5" SCH 40

PVC PIPE)

· TOTAL DYNAMIC HEAD = 53 FT

· ACTUAL FLOW RATE OF SEWAGE PUMP SELECTED IS:

· LIBERTY EFFLUENT PUMP, FL75, ¾ HP PUMP. BASED ON PUMP CURVE AT

53 FT OF HEAD PUMP PRODUCES 43 GPM

· 43 GPM IS BELOW THE 150 GPM NEEDED TO MAINTAIN AN IDEAL 2.5 PSI, AT

EACH ORIFICE, SO IDEAL PRESSURE WILL NOT BE MAINTAINED TO THE

FAR END OF THE DRAINFIELD. HOWEVER, ORIFICES ARE TURNED DOWN,

SO DISTRIBUTION LATERALS WILL STILL DRAIN BY GRAVITY, EVEN UNDER

0 PSI PRESSURE.

· RESULT WILL BE A LITTLE UNEVEN DISTRIBUTION WITHIN THE DRAINFIELD,

BUT KEEPS THE PUMP SIZE REASONABLE FOR OPERATIONAL COSTS AND

DOSING. IT IS NOT IDEAL, BUT WILL WORK. POSITIVE PRESSURE WILL

STILL BE MAINTAINED.

· 43 GPM / 128 ORIFICES = 0.34 GPM/ORIFICE (LESS THAN THE

RECOMMENDED 1.17 GPM/ORIFICE, BUT ACCEPTABLE)

DOSING OF DISTRIBUTION SYSTEM

· VOLUME OF PUMPING CHAMBER (LIBERTY PUMP BASIN)

· 36” DIAMETER, SAY FLOATS ARE 4 FT APART

· PUMP VOLUME IS ((3.14)*(D^2)/4) *(L) *(7.48 GAL/CU FT) =

((3.14)*(3FT^2)/4)*(4FT)*(7.48 GAL/CU FT) = 211 GALLONS.

· SET PUMP-OFF FLOAT AT 1FT FROM BOTTOM OF TANK, AND PUMP-ON WILL

BE ABOUT 5FT FROM THE BOTTOM OF TANK, RESULTING IN A PUMP

VOLUME OF ABOUT 211 GALLONS

· PUMP RUN TIME = 211 GAL/CYCLE / 43 GAL/MIN = 4.9 MIN/CYCLE

· PUMP CYCLE TIME = 750 GPD / 211 GAL/CYCLE = 3.6 CYCLES PER DAY

(ACCEPTABLE)

· THE REPS PUMP WILL RUN FOR 4.9 MIN/CYCLE * 3.6 CYCLES/DAY = 17.6

MINUTES PER DAY

SITE SPECIFIC DESIGN AND CONSTRUCTION NOTES

SEWER

· INSTALL 3 IMMERSION HEATERS, 2 IN THE SEPTIC TANK AND 1 IN THE LIFT

STATION. MIRACO, 110V, 500 WATT STOCK CERAMIC COATED STOCK TANK

HEATER, OR APPROVED EQUAL.

· HEAT TRACE WILL BE RUN ON THE SEWER LINE, FROM THE ARCTIC BOX,

TO THE SEPTIC TANK, AND PAST THE SEPTIC TANK AND LIFT STATION, TO

THE FORCE MAIN GOING TO THE MOUND DRAINFIELD.

· THE SYSTEM MUST DRAINBACK INTO THE PUMP CHAMBER AFTER EACH

PUMP CYCLE, SO THE PRESSURE LINE MUST SLOPE BACK TO THE PUMP

CHAMBER AND A 1/4” WEEP HOLE DRILLED UPSTREAM OF THE CHECK

VALVE, BUT DOWNSTREAM OF THE BALL VALVE. AN UPWARD FACING

ORIFICE WILL NEED TO BE INSTALLED AT THE END OF THE LATERAL IN THE

DRAINFIELD TO ALLOW AIR INTO THE SYSTEM TO DRAIN.

· AS THIS SYSTEM IS A REPS UNIT WITH PRESSURE DISTRIBUTION

DRAINFIELD, THE START-UP OF THE FACILITY SHALL BE COORDINATED

AND ARRANGED WITH THE PROJECT MANAGER AND ENGINEER.

SUCCESSFUL SYSTEM START-UP, TROUBLESHOOTING, AND ADDRESSING

ANY INSPECTION CONCERNS, MUST ALL BE COMPLETED BEFORE FINAL

CONTRACT PAYMENT.

· THE SEWER SERVICE LINE FROM THE HOUSE TO THE SEPTIC TANK WILL

BE 4” x 12” ARCTIC PIPE.

· THE SEPTIC TANK AND REPS UNIT WILL NEED TO BE INSULATED AND

COVERED WITH 4” OF INSULATION

· THE 2” HDPE PRESSURE LINE WILL BE RUN INSIDE A 4”X12” ARCTIC PIPE

CARRIER PIPE.

· THERE WILL BE A MINIMUM 4FT OF COVER OVER THE SEWER PIPE, SEPTIC

TANK, REPS UNIT, AND DRAINFIELD.

WATER

· THIS WELL IS CONSIDERED AN ARCTIC WELL AND WILL REQUIRE AN

INSULATED SLEEVE AROUND THE TOP 10FT OF WELL CASING AND

INCLUDE A FABRICATED ARCTIC CAP.

· THE 1” WATER SERVICE LINE WILL BE RUN INSIDE A 4” X 12” ARCTIC PIPE

CARRIER, WILL HAVE A MINIMUM OF 4' OF SOIL COVER.

· HEAT TRACE, INSIDE 1” PEX CARRIER PIPE, SHOULD EXTEND ALONG THE

WATER SERVICE LINE, INSIDE THE ARCTIC PIPE CARRIER, AND RUN UP

BETWEEN THE OUTSIDE OF THE CASING AND ARCTIC SLEEVE FOR EASE

OF REPLACEMENT. IT TRANSITIONS AT A JUNCTION BOX AT THE WELL

HEAD AND THEN ALSO RUNS BACK DOWN THE INSIDE OF THE CASING,

PAST THE PITLESS ADAPTER, DOWN BELOW WHERE THE PUMP IS SET,

WHEN IN PERMAFROST.

· THE PITLESS ADAPTER SHOULD BE INSTALLED A MINIMUM OF 8' BELOW

EXISTING GRADE TO PREVENT FREEZING ISSUES.

· A STANDARD ARCTIC WELL IS A DRAIN-BACK SYSTEM, BUT IF

PERMAFROST IS ENCOUNTERED, THEN A CIRCULATION SYSTEM IS

REQUIRED.

· IF THE SYSTEM IS A CIRCULATION SYSTEM, THEN THERE WILL BE TWO, 1”

WATERLINES INSIDE THE 4” X 12” CARRIER PIPE, ALONG WITH THE 1” HEAT

TRACE CARRIER PIPE. THIS REQUIRES A DOUBLE PITLESS ADAPTER. THE

RETURN OF THE DROP PIPE WILL OCCUR BELOW THE PERMAFROST

LAYER.

TH 8' (9-21-2021)

TH EL = 55'TH PHOTO (7-7-2021)

TH NOTES:

ENCOUNTERED WATER AT 3'.

PERC TEST LOG

DUE TO HIGH GROUNDWATER

AT 3FT BG, NO PERCOLATION

TEST WAS PERFORMED.

0'-0"

4'-0"

8'-0"

2'-0"

6'-0"

10'-0"

WELL-GRADED

GRAVEL W/ SAND (GW)

ORGANIC

WELL GRADED SAND,

FINE TO COARSE SAND

49 THST

ATE OF ALASKA

REENIGN

ANOISSE L E

FORPDERETS

GE

R

I

KURT D. SAUERS

CE-10280

SHEET OF

4500 Diplomacy Drive

B

C

1 2 3 4

M R

K D

AT

E

D

ES

C R

IP

TI

O N

PROJ MGR:

DRAWN BY:

DRUMS ENG:

PROJ ENG:

PLAN SET:

SHEET TITLE

Division of Environmental Health and Engineering

IN

IT

BAR IS ONE INCH ON

ORIGINAL DRAWING, IF NOT

ADJUST SCALES ACCORDINGLY

USER: MCYANDELL PRODUCT: Autodesk Civil 3D 2023 - English FILE: P:\Nome\AKA-22-OME_Phase_II\CAD\Civil\OME-C-STSITE_JBlandford.dwg LAYOUT: NOTES PRINTED: 5/1/2024 11:33:02 AM

0 1"

TOTAL SHEETSOF

C-103 5 6

MY

ML

KS

AKA-22-OME

JESSICA BLANDFORD

DESIGN NOTES

N O

M E, A K

SC

A

TT

ER

ED

S

IT

ES

PH

A

SE

II

IS

SU

ED

F O

R C

O N

ST

R

U C

TI

O

N

12'-0"

GROUNDWATER

WELL-GRADED

GRAVEL W/ SAND (GW)

SOIL ANALYSIS

3'-0"

05/01/2024

WS

WS

WS

WS

WS

O H

/E O

H /E

O H

/E O

H /E

O H

/E O

H /E

O H

/E O

H /E

FTSS

S S S S

S S

S S S S

S S S S

FT

ST

STCO

W

N12°00'20"E 245.00'

TH

W

B B

T 01

HB 01

HB 02

ST 01

LS 01

AB 01

55'

54'

56'

53'

W S

W S

W S

W S

W S

W S

W S

W S

W S

AB

TH

AB

0+00 0+20

0+

0+

1+

EL

EV

AT

IO

N

ELEVATIO

N

40'

50'

60'

70'

40'

50'

60'

70'

-0+10 0+00 0+10 0+20 0+30 0+40 0+50 0+60 0+70 0+80 0+90 1+00

EG

: 5

5.

8'

EG

: 5

5.

7'

EG

: 5

6.

2'

EG

: 5

6.

0'

EG

: 5

5.

8'

EG

: 5

5.

6'

EG

: 5

5.

2'

EG

: 5

4.

8'

EG

: 5

4.

5'

EG

: 5

4.

3'

EG

: 5

4.

1'

EG

: 5

4.

0'

FG

FG

FG

: 5

8.

2'

FG

: 5

8.

3'

FG

: 5

8.

3'

FG

: 5

9.

2'

FG

: 6

3.

0'

FG

: 6

3.

0'

FG

: 6

3.

0'

FG

: 5

9.

8'

FG

: 5

4.

8'

FG

HOUSE

FF=59.9'

ST

LS

VB

VB

T

AB

H B

H B

FM 04

FM 05

FM 06

AB

FM 07

SS 02 FM 03SS 01

MAJOR STRUCTURES

ID

AB 01

ST 01

LS 01

HB 01

HB 02

T 01

STATION

0+00.0

0+22.0

0+32.5

0+37.5

0+39.5

0+49.5

DESCRIPTION

ARCTIC BOX, SEE SSSD-303

1,500 GALLON ANC STEEL SEPTIC TANK, SEE SSSD-546

LIBERTY PUMP BASIN 36' X 11', SEE-SSSD-566 .

45° HORIZONTAL BEND, SEE SSSD-201

45° HORIZONTAL BEND, SEE SSSD-201

4" TEE, SEE SSSD-201

SEWER SERVICE

ID

SS 01

SS 02

FM 03

FM 04

FM 05

FM 06

FM 07

START

0+00

0+28

0+34

0+38

0+40

0+43

0+48

END

0+16

0+31

0+38

0+40

0+43

0+48

0+50

LENGTH

16 LF

3 LF

4 LF

2 LF

4 LF

7 LF

2 LF

SLOPE

2.0%

2.0%

0.0%

0.0%

0.0%

-100.0%

0.0%

DESCRIPTION

4" x 12" AGP W/ 4" INSULATION .

4" x 12" AGP W/ 4" INSULATION

4" x 12" ARCTIC PIPE

2" HDPE IN 4" x 12" AGP

W/ 2" INSULATION

2" HDPE IN 4" x 12" AGP

W/ 2" INSULATION

2" HDPE IN 4" x 12" AGP

W/ 2" INSULATION

2" HDPE IN 4" x 12" AGP

W/ 2" INSULATION

49 THST

ATE OF ALASKA

REENIGN

ANOISSE L E

FORPDERETS

GE

R

I

KURT D. SAUERS

CE-10280

HORZ. SCALE

VERT. SCALE

PLAN AND PROFILEA1

1" = 10' 1" = 10'

SEWER SWING TIE TABLE

DESC DSGN AB DESC DSGN AB

ST RISER I 19' DF PORT II 42'

ST RISER I 21' DF PORT II 26'

ST RISER II 28' DF PORT III 72'

ST RISER II 29' DF PORT III 64'

LIFT

STATION 33' DF PORT IV 65'

LIFT

STATION 34' DF PORT IV 61'

DF PORT I 28' WELL 16'

DF PORT I 17' WELL 14'

A 1 A 5

B 1 B 5

A 2 A 6

B 2 B 6

A 3 A 7

B 3 B 7

A 4 C W

B 4 D W

SHEET OF

4500 Diplomacy Drive

B

C

1 2 3 4

M R

K D

AT

E

D

ES

C R

IP

TI

O N

PROJ MGR:

DRAWN BY:

DRUMS ENG:

PROJ ENG:

PLAN SET:

SHEET TITLE

Division of Environmental Health and Engineering

IN

IT

BAR IS ONE INCH ON

ORIGINAL DRAWING, IF NOT

ADJUST SCALES ACCORDINGLY

USER: MCYANDELL PRODUCT: Autodesk Civil 3D 2023 - English FILE: P:\Nome\AKA-22-OME_Phase_II\CAD\Civil\OME-C-STSITE_JBlandford.dwg LAYOUT: DSGN PRINTED: 5/1/2024 3:53:48 PM

0 1"

TOTAL SHEETSOF

C-104 6 6

MY

ML

KS

AKA-22-OME

JESSICA BLANDFORD

DESIGN PLAN

N O

M E, A K

SC

A

TT

ER

ED

S

IT

ES

PH

A

SE

II

IS

SU

ED

F O

R C

O N

ST

R

U C

TI

O

N

CONTRACTOR AS-BUILTS:

COVER OVER SEWER SERVICE LINE:

SEPTIC TANK INVERT IN:

SEPTIC TANK INVERT OUT:

COVER OVER SEPTIC TANK:

COVER OVER CHAMBERS/ DRAINFIELD:

0 10' 20'

TWO STORY HOUSE

5 BEDROOM

FF= 59.9'

BED STYLE DRAINFIELD

64 CHAMBERS; 16 ROWS

OF 4 CHAMBERS (724 SF)

GRADING TABLE

ID DESCRIPTION VOL (CuYd) ELEV

EXCAVATION (EXC) 109 -

FILL (FG) 840 -

BOTTOM OF INFILTRATORS CHAMBERS 30 58'

BOTTOM OF 2' COARSE SEWER ROCK 80 56'

BOTTOM OF 2' COARSE SAND 80 54

BOTTOM OF SEPTIC TANK & LIFT STATION 14 49'

BOTTOM OF 2' SAND TANK BEDDING 9 48'

NET VOLUME: (A+B+C+D+E) - FILL (FG) -627 -

NET VOLUME = SEPTIC SYSTEM (EXCESS SOIL) - MOUND

POSITIVE VOLUME = EXCESS SOIL | NEGATIVE VOLUME = SOIL NEEDED

VALUES ARE ESTIMATED | EXPANSION & COMPACTION NOT FACTORED IN

A

B

C

D

E

EG

C

A

B

DE

100' EXISTING

WELL RADIUS

DRIVEWAY

RED FOX

ROAD

TEST HOLE

CAUTION:

OVERHEAD

ELECTRIC

GRAY WATER

DISCHARGE 4" PVC

ONE STORY HOUSE

TEST HOLE

1 2 3

5 6

A

B

FG = 63'

FG = 58.5'

49.33' MOUND & GRAVEL

.0

0'

CAUTION: AVOID CROSSING OVER PROPERTY

LINES. CONTRACTOR IS RESPONSIBLE FOR

ESTABLISHING PROPERTY LINES

NOTE:

1. ABANDON EXISTING SEPTIC SYSTEM PER DEC. REMOVE WOOD

STRUCTURE OVER TANK. CRUSH SEPTIC TANK IN PLACE. BUT KEEP

AWAY FROM NEW SEWER SERVICE LINE, PULL EXPOSED PIPES.

100'R EXISTING WELL CLEARANCE

C

D

.0

0'

53.33' SAND

INSTALL BOLLARDS

SEE SSSD-850

2:1

4" TEE4" TEE

CRAWL

SPACE

GW @ 3' BG

SEWER ROCK ELEVATION WAS SET TO MEET SEPARATION

DISTANCE TO AN ASSUMED IMPERMEABLE LAYER

INSTALL LIFT STATION ANCHOR

DUE TO GROUNDWATER SEE SSSD-566

WSL ~40LF

WSL ~73LF

INSTALL WELL,

SEE SSSD-730

GW @ 3' BG

CAUTION: THERE IS HIGH, FAST FLOWING

GROUNDWATER AT THIS SITE. APPROPRIATE

GROUNDWATER PUMPS WILL BE REQUIRED TO

DEWATER THE SITE IN ORDER TO SET THE

SEPTIC TANK AND LIFT STATION BASIN.

3'

1'

1'

2" THICK OF

3/4" MINUS SEWER

DRAIN ROCK

KEY GEOFABRIC

INTO BANK

USE PROPEX

WOVEN GEOTEXTILE

GEOTEX 200ST OR

FABRIC DRAINFIELD

DRAINAGE SWALE

3'W x 1'H x 50'L

DRAINAGE SWALE

HORIZONTAL SEPARATION

DISTANCES (NEAREST EDGE TO NEAREST EDGE IN FEET)

LIST DISTANCES

TO ALL

NEAREST:

PRIVATE

WELL

PUBLIC

WELL WATERLINE SURFACE

WATER

PROPERTY

LINE

SEPTIC TANK

SOIL

ABSORPTION

SYSTEM

LIFT STATION

SEWER LINE (S)

HORIZONTAL SEPARATION DISTANCE FROM SOIL ABSORPTION SYSTEM TO

SLOPE EXCEEDING 25%:

HOUSE

DUAL

COMPARTMENT

SEPTIC TANK

INFILTRATORS

2' MIN2' MIN

5' MAX

4' MIN

6' MIN

GROUND

WATER TABLE

IMPERMEABLE LAYER

ELEVATION VIEW

PLAN VIEW

INFILTRATORS

HOUSE

DISTRIBUTION BOX

SEPTIC TANK AND ABSORPTION FIELD SCHEMATICA1 NTS

SEPTIC TANK WITH PUMP AND PRESSURE MOUND SYSTEM SCHEMATICA3 NTS

HOUSE

DUAL

COMPARTMENT

SEPTIC TANK

INFILTRATORS

2' MIN

5' MAX

4' MIN

6' MIN

GROUND

WATER TABLE

IMPERMEABLE LAYER

ELEVATION VIEW

PLAN VIEW

DUAL

COMPARTMENT

SEPTIC TANK

HOUSE

PUMP CHAMBER

DUAL

COMPARTMENT

SEPTIC TANK

PUMP CHAMBER

CLEANOUT CLEANOUT

CLEANOUT

CLEANOUT

INSPECTION PIPE (TYP)

DISTRIBUTION BOX

INSPECTION PIPE (TYP)

INSPECTION PIPE (TYP)

INFILTRATORS

PRESSURE PIPE

INSPECTION PIPE (TYP)

PRESSURE PIPE

PUMP OUT PORTS

SHEET OF

4500 Diplomacy Drive Anchorage, Alaska 99508

(907) 729-3600

D

A

B

C

1 2 3 4

Division of Environmental Health and Engineering

BAR IS ONE INCH ON

ORIGINAL DRAWING, IF NOT

ADJUST SCALES ACCORDINGLY

USER: MCYANDELL PRODUCT: Autodesk Civil 3D 2023 - English FILE: P:\_Eng_Ref\z_Restricted_Access\_Scattered_Sites_Library\SSD-G-STSCOP.dwg LAYOUT: SSSD-100 SEPTIC SYSTEM SCHEMATIC PRINTED: 4/18/2024 3:58:07 PM

0 1"

TH

E

R

EG

IS

TE

R

ED

E N

G

IN

EE

R

F O

R T

H E

PR

O

JE

C

T

IS

R

ES

PO

N

SI

BL

E

FO

R T

H E

PR

O

PE

R

A

PP

LI

C

AT

IO

N A

N D

IN

TE

G R

AT

IO

N O

F

TH

ES

E

D

ET

AI

LS

A N

D A

N Y

M O

D

IF

IC

AT

IO

N

S

SH

O W

N . T

H E

AL

AS

KA

N

AT

IV

E

TR

IB

AL

H

EA

LT

H

C O

N

SO

R

TI

U M

(A N

TH

C

) O R

IT

S

AG

EN

TS

O

R E

M

PL

O

YE

ES

S

H

AL

L N

O T

BE

H

EL

D

R

ES

PO

N

SI

BL

E

FO

R T

H E

AC

C

U R

AC

Y

O R

C O

M

PL

ET

EN

ES

S

O F

SC

AN

N

ED

C O

PI

ES

O F

TH

IS

P

LA

N S

H

EE

T.

T

H

IS

D R

AW

IN

G H

AS

BE

EN

P

R

EP

AR

ED

B Y

AN

TH

C A

S

AN

IN

ST

R U

M

EN

T O

F

SE

R

VI

C E

AN

D

S H

AL

L

R

EM

AI

N

T H

E

PR

O

PE

R

TY

O F

AN

TH

C . A

N

TH

C S

H

AL

L R

ET

AI

N A

LL

C

O M

M O

N L

AW

, S

TA

TU

TO

R

Y

AN

D O

TH

ER

R

ES

ER

VE

D R

IG

H

TS

, I

N C

LU

D

IN

G

C O

PY

R

IG

H

T

TH

ER

ET

O

STANDARD

DETAIL

VERSION

SSSD-100

1 1

SE

PT

IC

S

YS

TE

M S

C H

EM

A

TI

C

1.0

NOT USED

8 OF 37 TOTAL SHEETS

05/01/2024

12" (TYP)

CONTINUOUS

WELD (TYP)CONTINUOUS

WELD (TYP)

SEE

SPECIFICATION

33 31 30

SEE

SPECIFICATION

33 31 30

SEE

SPECIFICATION

33 31 30

12" (TYP)

CONTINUOUS

WELD (TYP)

ARCTIC 11.25 DEGREE GRAVITY FITTINGA1 1" = 1'-0"

ARCTIC 45 DEGREE GRAVITY FITTINGA3 1" = 1'-0"

ARCTIC 22.5 DEGREE GRAVITY FITTINGB1 1" = 1'-0"

ARCTIC 90 DEGREE GRAVITY FITTINGB3 1" = 1'-0"

ARCTIC WYE GRAVITY FITTINGC1 1" = 1'-0"

ARCTIC LONG RADIUS 90 DEGREE GRAVITY FITTINGC3 1" = 1'-0"

ARCTIC GRAVITY PIPED1 1" = 1'-0"

CONTINUOUS

WELD (TYP)

12" (TYP)

R

X

Y

PIPE JACKET X Y R

3" 12.9" 34.6" 23.5" 10.5" 4" 12.9" 34.6" 23.5" 13.5" 6" 12.9" 34.6" 23.5" 19.9"

Y

X

PIPE JACKET X Y R

3" 12.9" 35.7" 35.7" 10.5" 4" 12.9" 35.7" 35.7" 13.5" 6" 12.9" 35.7" 35.7" 19.9"

12" (TYP)

R

X

Y

PIPE JACKET X Y R

3" 12.9" 26.3" 15.3" 10.5" 4" 12.9" 26.3" 15.3" 13.5" 6" 12.9" 26.3" 15.3" 19.9"

12" (TYP)

R

X

Y

PIPE JACKET X Y R

3" 12.9" 28.0" 17.5" 10.5" 4" 12.9" 28.0" 17.5" 13.5" 6" 12.9" 28.0" 17.5" 19.9"

CONTINUOUS

WELD (TYP)

X

Y

PIPE JACKET X Y

3" 12.9" 42.3" 40.5" 4" 12.9" 42.3" 40.5" 6" 12.9" 42.3" 40.5"

Y

PIPE JACKET X Y

3" 12.9" 20' 12.9" 4" 12.9" 20' 12.9" 6" 12.9" 20' 12.9"

X

12" (TYP)

CONTINUOUS

WELD (TYP)

R

Y

X PIPE JACKET X Y R

3" 12.9" 47.1" 47.1" 32.0" 4" 12.9" 47.1" 47.1" 32.0" 6" 12.9" 47.1" 47.1" 32.0"

R

SHEET OF

4500 Diplomacy Drive Anchorage, Alaska 99508

(907) 729-3600

D

A

B

C

1 2 3 4

Division of Environmental Health and Engineering

BAR IS ONE INCH ON

ORIGINAL DRAWING, IF NOT

ADJUST SCALES ACCORDINGLY

USER: MCYANDELL PRODUCT: Autodesk Civil 3D 2021 - English FILE: P:\_Eng_Ref\z_Restricted_Access\_Scattered_Sites_Library\SSD-C-DTAGPF.dwg LAYOUT: SSSD-200 ARCTIC GRAVITY PIPE AND FITTINGS PRINTED: 4/18/2024 3:58:17 PM

0 1"

TH

E

R

EG

IS

TE

R

ED

E N

G

IN

EE

R

F O

R T

H E

PR

O

JE

C

T

IS

R

ES

PO

N

SI

BL

E

FO

R T

H E

PR

O

PE

R

A

PP

LI

C

AT

IO

N A

N D

IN

TE

G R

AT

IO

N O

F

TH

ES

E

D

ET

AI

LS

A N

D A

N Y

M O

D

IF

IC

AT

IO

N

S

SH

O W

N . T

H E

AL

AS

KA

N

AT

IV

E

TR

IB

AL

H

EA

LT

H

C O

N

SO

R

TI

U M

(A N

TH

C

) O R

IT

S

AG

EN

TS

O

R E

M

PL

O

YE

ES

S

H

AL

L N

O T

BE

H

EL

D

R

ES

PO

N

SI

BL

E

FO

R T

H E

AC

C

U R

AC

Y

O R

C O

M

PL

ET

EN

ES

S

O F

SC

AN

N

ED

C O

PI

ES

O F

TH

IS

P

LA

N S

H

EE

T.

T

H

IS

D R

AW

IN

G H

AS

BE

EN

P

R

EP

AR

ED

B Y

AN

TH

C A

S

AN

IN

ST

R U

M

EN

T O

F

SE

R

VI

C E

AN

D

S H

AL

L

R

EM

AI

N

T H

E

PR

O

PE

R

TY

O F

AN

TH

C . A

N

TH

C S

H

AL

L R

ET

AI

N A

LL

C

O M

M O

N L

AW

, S

TA

TU

TO

R

Y

AN

D O

TH

ER

R

ES

ER

VE

D R

IG

H

TS

, I

N C

LU

D

IN

G

C O

PY

R

IG

H

T

TH

ER

ET

O

STANDARD

DETAIL

VERSION

SSSD-200

1 1

A R

C

TI

C G

R A

VI

TY

P

IP

E A

N D

FI

TT

IN

G

S

1.0

9 OF 37 TOTAL SHEETS

05/01/2024

12" (TYP)

12" (TYP)

12" (TYP)

12" (TYP)

12" (TYP)

12" (TYP)

12" (TYP)

12" (TYP)

12" (TYP)

12" (TYP)

A

12" (TYP)

12" (TYP)

ARCTIC 11.25 DEGREE PRESSURE FITTINGA1 1" = 1'-0"

ARCTIC 45 DEGREE PRESSURE FITTINGA3 1" = 1'-0"

ARCTIC 22.5 DEGREE PRESSURE FITTINGB1 1" = 1'-0"

ARCTIC 90 DEGREE PRESSURE FITTINGB3 1" = 1'-0"

ARCTIC TEE PRESSURE FITTINGC1 1" = 1'-0"

ARCTIC WYE PRESSURE FITTINGC3 1" = 1'-0"

ARCTIC PRESSURE PIPED1 1" = 1'-0"

ARCTIC TIGHT RADIUS 90 DEGREE PRESSURE FITTINGD3 1" = 1'-0"

12" (TYP)

R

RR

R

X

R

Y

Y

X

Y

X

X

Y

X

Y

X

Y

X

Y

Y

X; 40' - 0" OPTIONAL

A

PIPE JACKET X Y R

2" 2.2" 3" 12.9" 24.9" 24.9" 3.2" 4" 12.9" 24.9" 24.9" 4.1" 6" 12.9" 24.4" 24.9" 6" 8" 7.8"

PIPE JACKET X Y A

2" 45° 3" 12.9" 42.3" 30.6" 45° 4" 12.9" 42.3" 30.6" 45° 6" 12.9" 42.3" 30.6" 45°

PIPE JACKET X Y R

2" 7.1" 3" 12.9" 35.7" 35.7" 10.5" 4" 12.9" 35.7" 35.7" 13.5" 6" 12.9" 35.7" 35.7" 19.9" 8" 25.9"

PIPE JACKET X Y R

2" 7.1" 3" 12.9" 34.6" 23.5" 10.5" 4" 12.9" 34.6" 23.5" 13.5" 6" 12.9" 34.6" 23.5" 19.9" 8" 25.9"

PIPE JACKET X Y R

2" 7.1" 3" 12.9" 26.3" 15.3" 10.5" 4" 12.9" 26.3" 15.3" 13.5" 6" 12.9" 26.3" 15.3" 19.9" 8" 25.9"

PIPE JACKET X Y R

2" 7.1" 3" 12.9" 28.0" 17.5" 10.5" 4" 12.9" 28.0" 17.5" 13.5" 6" 12.9" 28.0" 17.5" 19.9" 8" 25.9"

PIPE JACKET X Y A

2" 90° 3" 12.9" 36.9" 26.9" 90° 4" 12.9" 36.9" 26.9" 90° 6" 12.9" 36.9" 26.9" 90°

PIPE JACKET X Y

2" 3" 12.9" 20' 12.9" 4" 12.9" 20' 12.9" 6" 12.9" 20' 12.9" 8"

SHEET OF

4500 Diplomacy Drive Anchorage, Alaska 99508

(907) 729-3600

D

A

B

C

1 2 3 4

Division of Environmental Health and Engineering

BAR IS ONE INCH ON

ORIGINAL DRAWING, IF NOT

ADJUST SCALES ACCORDINGLY

USER: MCYANDELL PRODUCT: Autodesk Civil 3D 2021 - English FILE: P:\_Eng_Ref\z_Restricted_Access\_Scattered_Sites_Library\SSD-C-DTAPPF.dwg LAYOUT: SSSD-201 ARCTIC PRESSURE PIPE FITTINGS PRINTED: 4/18/2024 3:58:28 PM

0 1"

TH

E

R

EG

IS

TE

R

ED

E N

G

IN

EE

R

F O

R T

H E

PR

O

JE

C

T

IS

R

ES

PO

N

SI

BL

E

FO

R T

H E

PR

O

PE

R

A

PP

LI

C

AT

IO

N A

N D

IN

TE

G R

AT

IO

N O

F

TH

ES

E

D

ET

AI

LS

A N

D A

N Y

M O

D

IF

IC

AT

IO

N

S

SH

O W

N . T

H E

AL

AS

KA

N

AT

IV

E

TR

IB

AL

H

EA

LT

H

C O

N

SO

R

TI

U M

(A N

TH

C

) O R

IT

S

AG

EN

TS

O

R E

M

PL

O

YE

ES

S

H

AL

L N

O T

BE

H

EL

D

R

ES

PO

N

SI

BL

E

FO

R T

H E

AC

C

U R

AC

Y

O R

C O

M

PL

ET

EN

ES

S

O F

SC

AN

N

ED

C O

PI

ES

O F

TH

IS

P

LA

N S

H

EE

T.

T

H

IS

D R

AW

IN

G H

AS

BE

EN

P

R

EP

AR

ED

B Y

AN

TH

C A

S

AN

IN

ST

R U

M

EN

T O

F

SE

R

VI

C E

AN

D

S H

AL

L

R

EM

AI

N

T H

E

PR

O

PE

R

TY

O F

AN

TH

C . A

N

TH

C S

H

AL

L R

ET

AI

N A

LL

C

O M

M O

N L

AW

, S

TA

TU

TO

R

Y

AN

D O

TH

ER

R

ES

ER

VE

D R

IG

H

TS

, I

N C

LU

D

IN

G

C O

PY

R

IG

H

T

TH

ER

ET

O

STANDARD

DETAIL

VERSION

SSSD-201

1 1

A R

C

TI

C P

R

ES

SU

R

E

PI

PE

F

IT

TI

N G

S

1.0

10 OF 37 TOTAL SHEETS

05/01/2024

WASHER

OD

WASHER

ID

2"

FLEXIBLE CLOSED CELL FOAM

INSULATION

6" (TYP) 6" (TYP)

COUPLING BAND METAL JACKET

ARCTIC PIPE

16 GAUGE MIN

THICKNESS, SINGLE

PIECE ALUMINUM

COUPLING BAND

1/2" x 6" CADMIUM-PLATED

CARRIAGE BOLT WITH

SHOULDERED NUT (TYP OF 3)

2" x 2" x 3/16" ALUMINUM ANGLE

ATTACHED TO BAND WITH

CONTINUOUS WELD (TYP)

COUPLING BAND

INSTALL INSULATION

WASHER EACH JOINT

METAL JACKET

ARCTIC PIPE

NOTES:

1. WATER MAIN JOINTS WILL BE INSTALLED A MINIMUM OF 10 FEET FROM

SEWER MAIN JOINTS.

2. IF POSSIBLE CENTER WATER MAIN AT THE SEWER MAIN CROSSING TO

MAXIMIZE JOINT SPACING.

3. FUSION JOINTS AT SEWER CROSSING WILL BE VISUALLY INSPECTED

BEFORE AND AFTER TO ENSURE JOINTS ARE FUSED PROPERLY.USE

FUSION JOINTS AT SEWER CROSSING TO PROVIDE SECONDARY

CONTAINMENT. RECORD INFORMATION IN JOINT FUSION LOG.

4. BUTT FUSION JOINTS ARE THE RECOMMENDED METHOD OF JOINING.

5. ELECTROFUSION COUPLINGS ARE NOT TO BE USED UNLESS

ABSOLUTELY NECESSARY.

6. WRAP JOINT WITH INSULATION HALF SHELL, CUT TO FIT, AND SEAL

WITH VISCOTAQ WRAP IN SATURATED AREAS.

7. ALL INSULATION DIMENSIONS ± 1/8".

2'-0"

NOMINAL

WASHER

DIMENSIONS

ID OD

2" 2 3/8" 8"

3" 3 1/2" 12"

4" 4 1/2" 12"

6" 6 5/8" 12"

8" 8 5/8" 16"

2" OVERLAP AT MAX BAND ID

SHEET OF

4500 Diplomacy Drive Anchorage, Alaska 99508

(907) 729-3600

D

A

B

C

1 2 3 4

Division of Environmental Health and Engineering

BAR IS ONE INCH ON

ORIGINAL DRAWING, IF NOT

ADJUST SCALES ACCORDINGLY

USER: MCYANDELL PRODUCT: Autodesk Civil 3D 2021 - English FILE: P:\_Eng_Ref\z_Restricted_Access\_Scattered_Sites_Library\SSD-C-DTCONS.dwg LAYOUT: SSSD-202 ARCTIC PIPE CONNECTIONS PRINTED: 4/18/2024 3:58:37 PM

0 1"

TH

E

R

EG

IS

TE

R

ED

E N

G

IN

EE

R

F O

R T

H E

PR

O

JE

C

T

IS

R

ES

PO

N

SI

BL

E

FO

R T

H E

PR

O

PE

R

A

PP

LI

C

AT

IO

N A

N D

IN

TE

G R

AT

IO

N O

F

TH

ES

E

D

ET

AI

LS

A N

D A

N Y

M O

D

IF

IC

AT

IO

N

S

SH

O W

N . T

H E

AL

AS

KA

N

AT

IV

E

TR

IB

AL

H

EA

LT

H

C O

N

SO

R

TI

U M

(A N

TH

C

) O R

IT

S

AG

EN

TS

O

R E

M

PL

O

YE

ES

S

H

AL

L N

O T

BE

H

EL

D

R

ES

PO

N

SI

BL

E

FO

R T

H E

AC

C

U R

AC

Y

O R

C O

M

PL

ET

EN

ES

S

O F

SC

AN

N

ED

C O

PI

ES

O F

TH

IS

P

LA

N S

H

EE

T.

T

H

IS

D R

AW

IN

G H

AS

BE

EN

P

R

EP

AR

ED

B Y

AN

TH

C A

S

AN

IN

ST

R U

M

EN

T O

F

SE

R

VI

C E

AN

D

S H

AL

L

R

EM

AI

N

T H

E

PR

O

PE

R

TY

O F

AN

TH

C . A

N

TH

C S

H

AL

L R

ET

AI

N A

LL

C

O M

M O

N L

AW

, S

TA

TU

TO

R

Y

AN

D O

TH

ER

R

ES

ER

VE

D R

IG

H

TS

, I

N C

LU

D

IN

G

C O

PY

R

IG

H

T

TH

ER

ET

O

STANDARD

DETAIL

VERSION

SSSD-202

1 1

A R

C

TI

C P

IP

E

C O

N N

EC

TI

O N

S

1.0

ARCTIC GRAVITY PIPE COUPLING BANDB3 1 1/2" = 1'-0"

ARCTIC GRAVITY PIPE CONNECTION - COUPLING BANDC3 1 1/2" = 1'-0"

GRAVITY PIPE INSULATION WASHERA3 1 1/2" = 1'-0"

11 OF 37 TOTAL SHEETS

05/01/2024

SEWER SERVICE - ARCTIC PIPEB1 1" = 1'-0"

10 GAUGE ALUMINUM

CAP WITH INSULATION

ATTACH TO ARCTIC

PIPE WITH 3 x 1/2" SELF

TAPPING SHEET METAL SCREWS

PULL ROPE ON

FROST PLUG

FLAT WASHER WITH KNOT

RUBBER JIM CAP

ON 4" ARCTIC PIPE

13"

12"

6"

TO SEPTIC TANK

OR SEWER MAIN

ARCTIC LATERAL TEE II

CARRIER PIPE

COUPLING BAND (TYP)

EXISTING

GROUND

INSULATION

WASHER (TYP)

ALUMINUM CAP

FROM HOUSE

(IF SINGLE)(BOTH IF DOUBLE)

ARCTIC LATERAL TEE I

2'-0"

FINISHED

FLOOR

WALL

CRAWLSPACE

OPTION 2:

4" PVC SCH 40 THROUGH

STEM-WALL PENETRATION

OPTION 3:

RUN SEWER SERVICE

LINE UNDER FOUNDATION

WALL AND FOOTER

OPTION 1:

USE ARCTIC BOX IF

SEWER CONNECTION

IS ABOVE GRADE

HOUSE

CONCRETE BLOCK

SEE SEWER SERVICE

TRENCH DETAILS

FOR BEDDING AND

BACKFILL REQUIREMENTS 4'-0" MIN

CRAWL

SPACE

WIDTH

VARIES

CONCRETE

STEM WALL

WOOD AND CONCRETE STEM WALL PENETRATION NOTE:

LOCATION OF STEM WALL PENETRATION SHALL BE APPROVED BY HOME OWNER AND FIELD VERIFIED TO ENSURE PROPER LOCATION.

PENETRATION TO BE CLEANLY CORED OR DRILLED.

ELASTOMERIC SEAL

ELEMENT LS MODEL

(C, L, S-316, O, OS-316, T)

(LINK SEAL)

LINK SEAL W/ BOLTS

CAST/CORE

DRILLED HOLE

SPRAYED

LOW-EXPANDING

URETHANE

INSULATION

INSULATE

WITH

SPRAYED

URETHANE

INSULATION

STEM WALL - CONCRETEA4 3" = 1'-0"

STEM WALL - WOODA3 3" = 1'-0"

BITUTHANE SHEET

COVED AROUND

PIPE, SEAL WITH

VISCOTAQ WRAP

SPRAYED

LOW-EXPANDING

URETHANE

INSULATION

1/2" PLYWOOD

CRAWL

SPACE

ALUMINUM CAPA1 3" = 1'-0"

4"x12" ARCTIC

PIPE (12.75"Ø, 10

GAUGE ALUMINUM

SPIR-L-LOCK JACKET)

SHEET OF

4500 Diplomacy Drive Anchorage, Alaska 99508

(907) 729-3600

D

A

B

C

1 2 3 4

Division of Environmental Health and Engineering

BAR IS ONE INCH ON

ORIGINAL DRAWING, IF NOT

ADJUST SCALES ACCORDINGLY

USER: MCYANDELL PRODUCT: Autodesk Civil 3D 2021 - English FILE: P:\_Eng_Ref\z_Restricted_Access\_Scattered_Sites_Library\SSD-C-DTSSWR.dwg LAYOUT: SSSD-300 SEWER SERVICE AND CLEANOUT - ARCTIC PIPE PRINTED: 4/18/2024 3:58:49 PM

0 1"

TH

E

R

EG

IS

TE

R

ED

E N

G

IN

EE

R

F O

R T

H E

PR

O

JE

C

T

IS

R

ES

PO

N

SI

BL

E

FO

R T

H E

PR

O

PE

R

A

PP

LI

C

AT

IO

N A

N D

IN

TE

G R

AT

IO

N O

F

TH

ES

E

D

ET

AI

LS

A N

D A

N Y

M O

D

IF

IC

AT

IO

N

S

SH

O W

N . T

H E

AL

AS

KA

N

AT

IV

E

TR

IB

AL

H

EA

LT

H

C O

N

SO

R

TI

U M

(A N

TH

C

) O R

IT

S

AG

EN

TS

O

R E

M

PL

O

YE

ES

S

H

AL

L N

O T

BE

H

EL

D

R

ES

PO

N

SI

BL

E

FO

R T

H E

AC

C

U R

AC

Y

O R

C O

M

PL

ET

EN

ES

S

O F

SC

AN

N

ED

C O

PI

ES

O F

TH

IS

P

LA

N S

H

EE

T.

T

H

IS

D R

AW

IN

G H

AS

BE

EN

P

R

EP

AR

ED

B Y

AN

TH

C A

S

AN

IN

ST

R U

M

EN

T O

F

SE

R

VI

C E

AN

D

S H

AL

L

R

EM

AI

N

T H

E

PR

O

PE

R

TY

O F

AN

TH

C . A

N

TH

C S

H

AL

L R

ET

AI

N A

LL

C

O M

M O

N L

AW

, S

TA

TU

TO

R

Y

AN

D O

TH

ER

R

ES

ER

VE

D R

IG

H

TS

, I

N C

LU

D

IN

G

C O

PY

R

IG

H

T

TH

ER

ET

O

STANDARD

DETAIL

VERSION

SSSD-300

1 1

SE

W

ER

S

ER

VI

C E

A N

D C

LE

A

N O

U T

A

R C

TI

C

P

IP

E

1.0

12 OF 37 TOTAL SHEETS

05/01/2024

2X6

(TYP)

2X4

(TYP)

15° BEVEL

8" x 50 MIL NEOPRENE

RUBBER ACROSS FULL WIDTH OF LID

24" SS CONTINUOUS

PIANO HINGE ATTACHED WITH

#10 x 3/4" PAN HEAD SS SCREWS

3/8"-16 x 4" HEX

HEAD CAP SCREW

3/8"-16 T-NUT

1'-0"

1'-11"

1'-11"

2' -4

1'-8"

2' -0

"1'-11 5/8"

2' -0

/1

6"

2'-5"

2'-3 1/4"

2" RIGID INSULATION (TYP)

1 1/2" RIGID INSULATION (TYP)

SIDE PANEL

SIDEPANEL

REMOVABLE

FRONT PANEL

LID

4" 1'

-5

1' -1

7/

8"

4 7/8"

DRILL 7/16" SLOT HOLES

FOR 3/8" x 2" HEADLESS

HANGER SCREWS WITH

HEX NUTS AND WASHERS

FOR REMOVABLE FRONT

PANEL OR USE WOOD TO

METAL DOWEL SCREWS WITH

WING NUTS (4 EA) ADD

HINGE TO BOTTOM OF

REMOVABLE FRONT PANEL

FOR DROP DOWN ACCESS

DRILL 7/16" HOLE

FOR 3/8" x 4" BOLTS

FOR LID TIE DOWN

BOX BOTTOM INSULATION

SHALL BE FIELD CUT FOR

PIPE PENETRATION

BEVEL LID AND UPPER

FRAMING MEMBERS 15°

26 GAUGE ALUMINUM

SHEATHING WITH A 3/4"

LIP ON 3 SIDES SO IT

CAN BE SLIPPED ONTO

THE LID (BOTH IN FRONT

OF AND BEHIND THE HINGE)

1'-11"

11 1/2"

11 1/2"

1 1/2" ALUMINUM THRESHOLD

ATTACHED WITH #10 x 3/4"

PAN HEAD SS SCREWS, @ 4" OC

BOTTOM PANEL

FOR WATER SERVICE

BOTTOM PANEL

FOR SEWER SERVICE

RIGHT SIDE PANEL

LID

CAULK BETWEEN HOUSE

AND BOX, PROVIDE BACKER

ROD FOR GAPS GREATER

THAN 3/16"

2'-0 1/4"

1'-11"

1'-11"

11 1/2"

9"

9"

8"

1'-11"

1' -1

0" 1' -6

/4

3 1/8"

2'-7 1/4"

1 3/8"

2' -6

/8

2'-1"

2' -6

/8

1'-11"

BACK

PANEL

5" FASTENMASTER HEADLOCK

SCREWS TOP AND BOTTOM

INTO HOUSE FRAMING WALL

STUD AND BOTTOM PLATE ON

EACH SIDE (TYP)

NOTES:

1. ALL BOX FRAMING HEM-FIR #2 OR BETTER.

2. BOX FRAMING IS ASSEMBLED WITH WOOD GLUE AND 3" DECK SCREWS.

3. BOX VERTICAL SHEATHING 5/8" T1-11 SIDING.

4. ATTACH BOX VERTICAL SHEATHING TO FRAMING WITH WOOD GLUE

AND 1 5/8" DECK SCREWS.

5. BOX LID, BOTTOM, AND BACK 5/8" EXTERIOR PLYWOOD.

6. ATTACH BOX BOTTOM TO FRAMING WITH WOOD GLUE AND 1 5/8"

DECK SCREWS.

7. LINE BOX WITH 2 LAYERS OF RIGID INSULATION 1 LAYER 1 1/2" AND 1

LAYER 2".

8. THE ARCTIC BOX COMPONENTS, BOTH THE WOOD FRAMING AND T1-11

SIDING, SHOULD BE SEALED AND PROTECTED FROM MOISTURE. BOTH

THE EXTERIOR AND INTERIOR OF THE BOX SHALL RECEIVE TWO

COATINGS OF THE SEALANT. THE SEALANT CAN HAVE A CLEAR FINISH,

SUCH AS CLEAR POLYURETHANE, OR THE BOX CAN BE SEALED WITH

PRIMER AND PAINTED WITH A WEATHERPROOF EXTERIOR GRADE

PAINT THAT MATCHES THE EXISTING HOUSE SIDING. IF THE BOXES ARE

MANUFACTURED AND SEALED OFF-SITE, THEY NEED TO BE

RE-TOUCHED UP IN THE FIELD AFTER INSTALLATION.

9. VERTICALLY LOCATE BOX TO ENSURE HOUSE PIPING PENETRATION

ALLOWS CONNECTION TO SERVICE LINE.

10. SEAL ALL JOINTS IN INSULATION WITH SILICONE CAULK.

11. AFTER COMPLETING ARCTIC BOX PLUMBING CONNECTIONS FILL VOID

SPACE IN BOX WITH FIBERGLASS BATT INSULATION SEALED IN PLASTIC

BAGS.

ADD HINGE FOR DROP

DOWN ACCESS TO FRONT

PANEL AND CLEAN OUT

UTILITY BOX REAR FRAMINGA1 1" = 1'-0"

LID TIE DOWN SECTIONA2 3" = 1'-0"

UTILITY BOX SECTIONA3 3" = 1'-0"

UTILITY BOX ISOMETRICB1 NTS

SHEET OF

4500 Diplomacy Drive Anchorage, Alaska 99508

(907) 729-3600

D

A

B

C

1 2 3 4

Division of Environmental Health and Engineering

BAR IS ONE INCH ON

ORIGINAL DRAWING, IF NOT

ADJUST SCALES ACCORDINGLY

USER: MCYANDELL PRODUCT: Autodesk Civil 3D 2021 - English FILE: P:\_Eng_Ref\z_Restricted_Access\_Scattered_Sites_Library\SSD-C-DTABOX.dwg LAYOUT: SSSD-304 SERVICE UTILITY BOX PRINTED: 4/18/2024 3:59:08 PM

0 1"

TH

E

R

EG

IS

TE

R

ED

E N

G

IN

EE

R

F O

R T

H E

PR

O

JE

C

T

IS

R

ES

PO

N

SI

BL

E

FO

R T

H E

PR

O

PE

R

A

PP

LI

C

AT

IO

N A

N D

IN

TE

G R

AT

IO

N O

F

TH

ES

E

D

ET

AI

LS

A N

D A

N Y

M O

D

IF

IC

AT

IO

N

S

SH

O W

N . T

H E

AL

AS

KA

N

AT

IV

E

TR

IB

AL

H

EA

LT

H

C O

N

SO

R

TI

U M

(A N

TH

C

) O R

IT

S

AG

EN

TS

O

R E

M

PL

O

YE

ES

S

H

AL

L N

O T

BE

H

EL

D

R

ES

PO

N

SI

BL

E

FO

R T

H E

AC

C

U R

AC

Y

O R

C O

M

PL

ET

EN

ES

S

O F

SC

AN

N

ED

C O

PI

ES

O F

TH

IS

P

LA

N S

H

EE

T.

T

H

IS

D R

AW

IN

G H

AS

BE

EN

P

R

EP

AR

ED

B Y

AN

TH

C A

S

AN

IN

ST

R U

M

EN

T O

F

SE

R

VI

C E

AN

D

S H

AL

L

R

EM

AI

N

T H

E

PR

O

PE

R

TY

O F

AN

TH

C . A

N

TH

C S

H

AL

L R

ET

AI

N A

LL

C

O M

M O

N L

AW

, S

TA

TU

TO

R

Y

AN

D O

TH

ER

R

ES

ER

VE

D R

IG

H

TS

, I

N C

LU

D

IN

G

C O

PY

R

IG

H

T

TH

ER

ET

O

STANDARD

DETAIL

VERSION

SSSD-304

1 1

SE

R

VI

C

E U

TI

LI

TY

B

O X

1.0

13 OF 37 TOTAL SHEETS

05/01/2024

ARCTIC SEWER SERVICE - BELOW FINISHED FLOORA2 1 1/2" = 1'-0"

OPTION 1B

EXISTING GROUND

3" ABS DWV SPIGOT

CLEANOUT INSERTS, 2 EACH

3" ABS DWV

DOUBLE SANITARY TEE

3" ABS DWV PIPE

3" FERNCO FLEXIBLE

COUPLING 1056 x 33

TO 3" TURBO SLEEVE (TYP)

ARCTIC SERVICE BOX

FILL SPACE WITH

BAGGED FIBERGLASS

BATTING INSULATION

FINISHED FLOOR

18" ALUMINUM

COUPLING

(TYP EACH JOINT)

4" ARCTIC LONG RADIUS

90° GRAVITY FITTING

INSULATION

WASHER AT

JOINTS (TYP)

PROVIDE THREE WRAPS

OF 6 MIL POLYETHYLENE

SHEETING ON VERTICAL

SECTION (TYP)

ARCTIC BOOT WITH

FLANGE ADAPTER

RING (TO INCLUDE

6" OF EXPANSION /

C0NTRACTION SLACK)

FLEXIBLE FOAM

INSULATION

WASHER (4 EACH)

1/2" STAINLESS

STEEL HOSE CLAMP (TYP)

6"

4" HDPE ARCTIC PIPE

3" SILICONE TURBO SLEEVE

- MIN 12" INSERTION

GREASE OR LUBRICATE

PIPE COLD TEMP GREASE

SLOPE 2% MIN TO SEWER

MAIN OR SEPTIC TANK

BURY DEPTH

4'-0" MIN

4" ARCTIC PIPE

(INSULATED AND

JACKETED 4" HDPE

PIPE) WITH 12" OD

INTERIOR

OF HOME

CRAWLSPACE

SEAL PENETRATIONWITH SILICONE

CAULKING TO MAINTAIN INTEGRITY

OF HOUSE WRAP AND VAPOR RETARDER

4" (2EA-2") RIGID

BOARDSTUCK INSULATION

(3 SIDES TYP)

CONNECT TO

EXISTING WASTEWATER

DRAIN PIPING

3/4" PRESSURE

TREATED PLYWOOD

3/4" PRESSURE

TREATED PLYWOOD

UTILIDOR SECTIOND1 1" = 4'

CONTINUE AS ARCTIC

PIPE OR TRANSITION

TO UNINSULATED PVC

OR ABS PIPE

MOUNT TO

FLOOR JOISTS

PIPEHANGER

4" ABS PIPE

HEAT TRACE

FLOOR

2" EXTRUDED POLYSTYRENE

RIGID INSULATION (4" TOTAL)

2" X 4" FIR LUMBER

1/2" PRESSURE

TREATED PLYWOOD

1'-9 1/2"

1'-6"

1/2" x 4"

LAG SCREWS

FLOOR PENETRATION

NOTE: LENGTH OF

UTILIDOR WILL BE

DEPENDENT ON

INDIVIDUAL HOUSE

AND DISTANCE TO

PLUMBING

PENETRATION

SHEET OF

4500 Diplomacy Drive Anchorage, Alaska 99508

(907) 729-3600

D

A

B

C

1 2 3 4

Division of Environmental Health and Engineering

BAR IS ONE INCH ON

ORIGINAL DRAWING, IF NOT

ADJUST SCALES ACCORDINGLY

USER: JEELLORIN PRODUCT: Autodesk Civil 3D 2023 - English FILE: P:\_Eng_Ref\z_Restricted_Access\_Scattered_Sites_Library\SSD-C-DTSSVC.dwg LAYOUT: SSSD-306 PRINTED: 4/18/2024 3:59:17 PM

0 1"

TH

E

R

EG

IS

TE

R

ED

E N

G

IN

EE

R

F O

R T

H E

PR

O

JE

C

T

IS

R

ES

PO

N

SI

BL

E

FO

R T

H E

PR

O

PE

R

A

PP

LI

C

AT

IO

N A

N D

IN

TE

G R

AT

IO

N O

F

TH

ES

E

D

ET

AI

LS

A N

D A

N Y

M O

D

IF

IC

AT

IO

N

S

SH

O W

N . T

H E

AL

AS

KA

N

AT

IV

E

TR

IB

AL

H

EA

LT

H

C O

N

SO

R

TI

U M

(A N

TH

C

) O R

IT

S

AG

EN

TS

O

R E

M

PL

O

YE

ES

S

H

AL

L N

O T

BE

H

EL

D

R

ES

PO

N

SI

BL

E

FO

R T

H E

AC

C

U R

AC

Y

O R

C O

M

PL

ET

EN

ES

S

O F

SC

AN

N

ED

C O

PI

ES

O F

TH

IS

P

LA

N S

H

EE

T.

T

H

IS

D R

AW

IN

G H

AS

BE

EN

P

R

EP

AR

ED

B Y

AN

TH

C A

S

AN

IN

ST

R U

M

EN

T O

F

SE

R

VI

C E

AN

D

S H

AL

L

R

EM

AI

N

T H

E

PR

O

PE

R

TY

O F

AN

TH

C . A

N

TH

C S

H

AL

L R

ET

AI

N A

LL

C

O M

M O

N L

AW

, S

TA

TU

TO

R

Y

AN

D O

TH

ER

R

ES

ER

VE

D R

IG

H

TS

, I

N C

LU

D

IN

G

C O

PY

R

IG

H

T

TH

ER

ET

O

STANDARD

DETAIL

VERSION

SSSD-306

1 1

SE

R

VI

C

E U

TI

LI

TY

B

O X

SE

W

ER

H

O U

SE

B

EL

O W

F

IN

IS

H

ED

F

LO

O

R

1.0

3" ABS

14 OF 37 TOTAL SHEETS

05/01/2024

NOTES:

1. SEE SPECIFICATION FOR ADDITONAL EARTHWORKS REQUIREMENTS.

2. SEE SPECIFICATION FOR SEEDING REQUIREMENTS.

3. 4" MIN GRAVEL LEVELING COURSE, COMPACTED, IN DRIVEWAYS AND

ROADWAYS ONLY.

4. 12" TOPSOIL OVER COMPACTED FILL, 12" OVER SURROUNDING GRADE,

RAKED SMOOTH, MOUNDED AND LANDSCAPED WITH GRADE AND

FERTILIZED, EXCEPT NEAR HOME. MOUND SHOULD SLOPE WATER AWAY

FROM HOME.

5. LIMITS OF EXCAVATION, TYP. MINIMUM SLOPE OR PROTECTIVE SYSTEM AS

REQUIRED BY OSHA - BASED ON SOIL TYPE AND CONDITIONS 1 1/2 :1

SHOWN FOR TYPE C SOILS FOR REFERENCE.

6. WHERE DRIVEWAY IS IMPACTED FROM CONSTRUCTION ACTIVITIES,

REPLACE WITH 4" OF D1 SPECIFIED GRAVEL AND GEOGABRIC AND

COMPACT AND LEVEL

6" MIN

(TYP ALL SIDES)

4'-0" MIN

CLEAN

COMPACTED

BACKFILL

6" WIDE

HAZARD TAPE

3/4" MINUS GRAVEL OR SAND PIPE BEDDING,

SEE SPECIFICATIONS

NATIVE MATERIAL

2'-0"

ARCTIC PIPE, 4" x 12"

1.5

(2) 2" THICK x 24" WIDE BOARDSTOCK

1.5

4" PVC. SCH 40 PIPE OR 4" ABS PIPE

6" MIN

(TYP ALL SIDES)

4'-0" MIN

CLEAN

COMPACTED

BACKFILL

6" WIDE HAZARD TAPE

3/4" MINUS GRAVEL OR SAND PIPE BEDDING,

SEE SPECIFICATIONS

NATIVE MATERIAL

2'-0"

1.5

1.5

3 4

3 4

OPTION 1:

EXISTING DRIVEWAY, SIDEWALK, OR PATHWAY

OPTION 2:

YARD AND NON-PAVED AREA

OPTION 1:

EXISTING DRIVEWAY, SIDEWALK, OR PATHWAY

OPTION 2:

YARD AND NON-PAVED AREA

SEWER TRENCH DETAIL - ABS OR PVC PIPEA1 3/4" = 1'-0"

SEWER TRENCH DETAIL - ARCTIC PIPEC1 3/4" = 1'-0"

6" MIN

6" MIN

4"

1" PEX HEAT TRACE CARRIER PIPE

SHEET OF

4500 Diplomacy Drive Anchorage, Alaska 99508

(907) 729-3600

D

A

B

C

1 2 3 4

Division of Environmental Health and Engineering

BAR IS ONE INCH ON

ORIGINAL DRAWING, IF NOT

ADJUST SCALES ACCORDINGLY

USER: JEELLORIN PRODUCT: Autodesk Civil 3D 2023 - English FILE: P:\_Eng_Ref\z_Restricted_Access\_Scattered_Sites_Library\SSD-C-DTRNC.dwg LAYOUT: SSSD-400 SEWER SERVICE LINE TRENCH PRINTED: 4/18/2024 3:59:28 PM

0 1"

TH

E

R

EG

IS

TE

R

ED

E N

G

IN

EE

R

F O

R T

H E

PR

O

JE

C

T

IS

R

ES

PO

N

SI

BL

E

FO

R T

H E

PR

O

PE

R

A

PP

LI

C

AT

IO

N A

N D

IN

TE

G R

AT

IO

N O

F

TH

ES

E

D

ET

AI

LS

A N

D A

N Y

M O

D

IF

IC

AT

IO

N

S

SH

O W

N . T

H E

AL

AS

KA

N

AT

IV

E

TR

IB

AL

H

EA

LT

H

C O

N

SO

R

TI

U M

(A N

TH

C

) O R

IT

S

AG

EN

TS

O

R E

M

PL

O

YE

ES

S

H

AL

L N

O T

BE

H

EL

D

R

ES

PO

N

SI

BL

E

FO

R T

H E

AC

C

U…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .