4-3-3F Drawings.pdf
PDF 10 MB Posted
- Attached to
- PIP-II CPB Overhead Door Mods
- Solicitation number
- Not on record
About this file
This document appears to be a set of drawings labeled "4-3-3F Drawings.pdf" related to the federal contract opportunity titled "PIP-II CPB Overhead Door Mods".
The key details of the federal contract opportunity are:
- Solicitation Number: PIPIICPBDoorsSTE
- Scope of Work: Temporary protective measures including fire-resistant partitions, demolition and removal of existing metal siding, structural steel, personnel door, and overhead coiling door, architectural work including installation of a new overhead coiling door, guideways, tracks, flashings, and relocation of an existing personnel door, painting, and electrical work for power connections, security systems, and cable tray
- Agency: Department of Energy Fermi National Accelerator Laboratory
- This is a pre-solicitation notice, indicating the final drawings and project manual may change.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 4-3-3F Project Manual.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
ealcaraz Image ealcaraz Image ealcaraz Callout
REMOVE EXISTING OVERHEAD DOOR AND PROVIDE TO FRA
ealcaraz Callout REMOVE EXISTING CONCRETE BOLLARD AND STAINLESS STEEL BOLLARD COVER ADN PROVIDE TO FRA AND SAWCUT/GRIND CONCRETE FOUNDATION FLUSH WITH ASPHALT PAVEMENT ealcaraz Callout
REMOVE AND RELOCATE EXISTING DOOR
ealcaraz Callout
REMOVE EXISTING METAL WALL PANEL AND DISPOSE
ealcaraz Callout
REMOVE AND RELOCATE EXISTING METAL WALL PANELS
ealcaraz PolyLine ealcaraz Callout
REMOVE EXISTING OVERHEAD COILING DOOR AND PROVIDE TO FRA
ealcaraz Callout
REMOVE EXISTING OVERHEAD COILING DOOR HOOD AND PROVIDE TO FRA
ealcaraz Arrow ealcaraz Polygon ealcaraz Callout
REMOVE AND RELOCATE EXISTING DOOR
ealcaraz Text Box
EXTERIOR EAST ELEVATION
(NORTH OVERHEAD DOOR)
ealcaraz Text Box
INTERIOR EAST ELEVATION
(NORTH OVERHEAD DOOR)
ealcaraz Image ealcaraz Text Box
ENLARGED FRAMING PLAN VIEW
(NORTH OVERHEAD DOOR)
ealcaraz Callout REMOVE AND RELOCATE EXISTING HSS6x6x3/8 POST ealcaraz Arrow ealcaraz Callout
REMOVE AND RELOCATE FIRE ALARM/PROTECTION
ealcaraz Callout
REMOVE AND RELOCATE FIRE EXTINGUISHER
ealcaraz Callout REMOVE AND RELOCATE COLD FORMED STEEL FRAMING BEHIND WALL TO ACCOMODATE NEW FRAMING SCHEME ealcaraz Text Box
SWITCH
ealcaraz Text Box
SWITCH
ealcaraz Image ealcaraz Text Box
EAST ELEVATION STRUCTURAL FRAMING
(NORTH OVERHEAD DOOR)
ealcaraz Callout REMOVE AND RELOCATE EXISTING HSS6x6x3/8 POST ealcaraz Callout
REMOVE AND RELOCATE ALL ELECTRICAL ELEMENTS ON AND BEHIND WALL
ealcaraz Image ealcaraz Image ealcaraz Image ealcaraz Rectangle ealcaraz Rectangle ealcaraz Rectangle ealcaraz Rectangle ealcaraz Rectangle ealcaraz Rectangle ealcaraz Text Box
ENLARGED FRAMING PLAN VIEW
(NORTH OVERHEAD DOOR)
ealcaraz Rectangle ealcaraz Text Box
EXTERIOR EAST ELEVATION
(NORTH OVERHEAD DOOR)
ealcaraz Callout
NEW OVERHEAD COILING DOOR (SEE NOTE 1)
ealcaraz Callout
RELOCATED DOOR (SEE NOTE 2)
ealcaraz Callout
RELOCATED METAL WALL PANELS (SEE NOTE 2)
ealcaraz Text Box
NOTES:
1. SUBCONTRACTOR SHALL PROVIDE NEW OVERHEAD COILING DOOR AND HOOD AND REUSE MOTOR AND ELECTRICAL COMPONENTS IF THEY MEET THE NEW LOAD AND ELECTRICAL REQUIREMENTS.
2. SUBCONTRACTOR SHALL RELOCATE ALL ELEMENTS TO PROVIDE A CLEAR OPENING OF 17'-0' WIDE BY 16'-0" TALL
3. SUBCONTRACTOR SHALL PROVIDE BUILDING WEATHER PROTECTION AND EGRESS TO WITHSTAND ALL ELEMENTS DURING CONSTRUCTION.
4. ALL LINEWORK SHOWN IN MONOCHROME IS EXISTING.
5. RELOCATE HOOD OVER STEEL TUBE IF NECESSARY TO ACHIEVE 16'-0" CLEAR HEIGHT AND SUPPORT ACCORDINGLY.
6. EXISTING METAL WALL PANELS WERE MANUFACTURED BY CENTRIA AND INSTALLED BY G&L ASSOCIATES. EXISTING OVERHEAD COILING DOOR WAS MANUFACTURED BY COOKSON DOOR.
ealcaraz Callout RELOCATED HSS6x6x3/8 POST (SEE NOTE 2) ealcaraz Rectangle ealcaraz Line ealcaraz Line ealcaraz Line ealcaraz Text Box 24 1/4" ealcaraz PolyLine ealcaraz Arrow ealcaraz Text Box
EXISTING OVERHEAD COILING DOOR (FOR REFERENCE)
(NORTH OVERHEAD DOOR)
ealcaraz Image ealcaraz Line ealcaraz Line ealcaraz Text Box
17'-0" MINIMUM
ealcaraz Line ealcaraz Text Box
16'-0" MINIMUM
ealcaraz Line ealcaraz Image ealcaraz Callout
NEW OVERHEAD COILING DOOR (SEE NOTE 1)
ealcaraz Rectangle ealcaraz Rectangle ealcaraz Callout
RELOCATED DOOR (SEE NOTE 2)
ealcaraz Rectangle ealcaraz Rectangle ealcaraz Callout
NEW OVERHEAD COILING DOOR HOOD (SEE NOTE 5)
ealcaraz Text Box
INTERIOR EAST ELEVATION
(NORTH OVERHEAD DOOR)
ealcaraz Rectangle ealcaraz Callout NEW AND/OR REWORKED COLD FORMED STEEL FRAMING, DRYWALL, ELECTRICAL AND FIRE PROTECION
| D-01 |
| SK-01 |