4-04 BicentennialParkRoofReplacements 20260908.pdf

PDF 3 MB Posted

Attached to
Bicentennial Park Pavilion C and Roof Replacements
Solicitation number
US.260327
Issued by
Northampton County, Pennsylvania

About this file

Summary

This document is a set of architectural and engineering plans prepared by Hanover Engineering Associates, Inc. for East Allen Township, Northampton County, Pennsylvania, detailing roof replacement specifications for Bicentennial Park. The project encompasses four structures: Pavilion A (2,108 square feet of new roofing), Pavilion B (1,300 square feet of new roofing), the Restroom Building (850 square feet of new roofing), and the Maintenance Building (2,100 square feet of new roofing). The proposal submission deadline is December 3, 2026, at 1:00 p.m. via the PennBid program, with public opening of proposals at the Township Engineer's Office in Bethlehem, Pennsylvania. A non-mandatory pre-bid conference is scheduled for November 17, 2026, at 2:00 p.m. at Pavilion B Parking Lot, and final questions must be submitted by 4:00 p.m. on November 24, 2026. Bidders are required to submit a bid bond or other acceptable security equal to 10% of the total base bid, and bids shall remain effective for 60 calendar days from the opening date.

The scope of work includes demolition of existing asphalt roof shingles, felt paper, drip edge, fascia, and soffits; removal of deteriorated plywood roof decking where required; and installation of new 30-pound asphalt-impregnated felt, 22-gauge raised panel steel roofing (color selected by owner), metal fascia, metal drip edge, snow guards, and louvered gable vents. All work must conform to the Uniform Construction Code and the 2018 International Building Code. The Restroom Building and Maintenance Building require additional work including new metal siding and soffit installation. Contractors must comply with the Pennsylvania Prevailing Wage Act and include prevailing wage requirements in all subcontracts. Specific pricing terms are not provided in this technical specification document; pricing information will be determined through the formal bidding process outlined in the contract documents available through the PennBid platform.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Br od he ad

R oa d, S ui te

Be th le he m , P

A

7-

P :6

.6

.5

F:

0.

1.

H an ov er En g.

co m

Be th le he m O ffi ce

AutoCAD SHX Text

NORTH ELEVATION (LOOKING SOUTH) SCALE "=1'-0"14"=1'-0"

AutoCAD SHX Text 27'-5"

AutoCAD SHX Text 1'-4"

AutoCAD SHX Text 1'-4"

AutoCAD SHX Text

OVERHANG

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

11'-11 " (REF)516" (REF)

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

15'-7 " (REF)916" (REF)

AutoCAD SHX Text

EXISTING 8" BLOCK WALL

AutoCAD SHX Text

INSTALL NEW METAL SIDING, COLOR BY OWNER

AutoCAD SHX Text 2'-0"

AutoCAD SHX Text 2'-3 "12"

AutoCAD SHX Text 2'-0"

AutoCAD SHX Text 2'-3 "12"

AutoCAD SHX Text

INSTALL NEW METAL FASCIA, COLOR BY OWNER

AutoCAD SHX Text INSTALL NEW 18"x24" RECTANGULAR PVC WEATHER FILTER GABLE LOUVER VENT, COLOR TO MATCH ROOF

AutoCAD SHX Text

EXISTING SECURITY CAMERA TO REMAIN

AutoCAD SHX Text

EXISTING FIXTURE TO REMAIN

AutoCAD SHX Text

EXISTING SECURITY SENDING MAST TO REMAIN

AutoCAD SHX Text

WEST ELEVATION (LOOKING EAST) SCALE "=1'-0"14"=1'-0"

AutoCAD SHX Text 17'-11"

AutoCAD SHX Text

EXISTING PAVILION

AutoCAD SHX Text

EXISTING RESTROOMS

AutoCAD SHX Text 47'-10"

AutoCAD SHX Text 1 "12"

AutoCAD SHX Text 1 "12"

AutoCAD SHX Text

OVERHANG

AutoCAD SHX Text 1'-4"

AutoCAD SHX Text 1'-4"

AutoCAD SHX Text

OVERHANG

AutoCAD SHX Text INSTALL NEW 30# ASPHALT IMPREGNATED FELT OVER ENTIRE ROOF, INSTALL NEW 22 GAUGE RAISED PANEL STEEL ROOF, COLOR BY OWNER

AutoCAD SHX Text 67'-2 "12"

AutoCAD SHX Text

NOTE: : PAVILION A DOES NOT HAVE RAIN GUTTERS OR DOWNSPOUTS

AutoCAD SHX Text

EXISTING 8" BLOCK WALL

AutoCAD SHX Text

EXISTING 8" BLOCK (TYP)

AutoCAD SHX Text

INSTALL SNOW GUARDS STAGGERED, TYPICAL ON BOTH SIDES OF ROOF.

AutoCAD SHX Text

INSTALL NEW METAL FASCIA, COLOR BY OWNER

AutoCAD SHX Text A

AutoCAD SHX Text

AutoCAD SHX Text N

AutoCAD SHX Text

(REFERENCE)

AutoCAD SHX Text 65'-9"

AutoCAD SHX Text

PLAN VIEW - ROOF EXISTING PAVILION A SCALE "=1'-0"14"=1'-0"

AutoCAD SHX Text 27'-5"

AutoCAD SHX Text 1'-4"

AutoCAD SHX Text 1'-4"

AutoCAD SHX Text

OVERHANG

AutoCAD SHX Text 1'-4"

AutoCAD SHX Text 1'-4"

AutoCAD SHX Text

OVERHANG

AutoCAD SHX Text 1 "12"

AutoCAD SHX Text 1 "12"

AutoCAD SHX Text

OVERHANG

AutoCAD SHX Text 67'-2 "12"

AutoCAD SHX Text 1'-4"

AutoCAD SHX Text 1'-4"

AutoCAD SHX Text

OVERHANG

AutoCAD SHX Text 30'-1"

AutoCAD SHX Text

EXISTING 8" CMU WALL BELOW

AutoCAD SHX Text

EXISTING 8" CMU WALL BELOW

AutoCAD SHX Text

SLOPE

AutoCAD SHX Text

SLOPE

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

ROOF RIDGE

AutoCAD SHX Text INSTALL NEW 30# ASPHALT IMPREGNATED FELT OVER ENTIRE ROOF, INSTALL 2108 SQUARE FOOT OF NEW 22 GAUGE RAISED PANEL ROOF, COLOR BY OWNER

AutoCAD SHX Text RETAIN EXISTING PLYWOOD ROOF DECKING, REPLACE DETERIORATED ROOF DECKING AS REQUIRED.

AutoCAD SHX Text

INSTALL NEW METAL FASCIA, COLOR BY OWNER (TYP)

AutoCAD SHX Text

OUTLINE OF WALLS BELOW (TYP)

AutoCAD SHX Text

NEW 22 GAUGE RAISED PANEL ROOF

AutoCAD SHX Text

NEW 22 GAUGE RAISED PANEL ROOF

AutoCAD SHX Text A

AutoCAD SHX Text

AutoCAD SHX Text THIS DOCUMENT IS THE PROPERTY OF HANOVER ENGINEERING ASSOCIATES, INC. ANY USE OF A COPY OF THIS DOCUMENT THAT DOES NOT CONTAIN AN ORIGINAL SEAL AND SIGNATURE IS STRICTLY PROHIBITED. THIS DOCUMENT IS NOT PUBLISHED AND ALL RIGHTS ARE RESERVED BY HANOVER ENGINEERING ASSOCIATES, INC. THIS PLAN HAS BEEN SEALED WITH EITHER A RED INK SEAL OR A CRIMP SEAL. IF NEITHER APPEARS ON THIS PLAN, POSSIBLE REPRODUCTIONS OR ALTERATIONS MAY HAVE BEEN MADE WITHOUT THE APPROVAL OR KNOWLEDGE OF THE SIGNATORY.

AutoCAD SHX Text

DATE

AutoCAD SHX Text

NO.

AutoCAD SHX Text

REVISIONS

AutoCAD SHX Text

PLAN TITLE:

AutoCAD SHX Text

PROJECT TITLE:

AutoCAD SHX Text

SEAL:

AutoCAD SHX Text

OF

AutoCAD SHX Text

SHEET NO.

AutoCAD SHX Text

PROJECT NO.

AutoCAD SHX Text

DRAWN BY:

AutoCAD SHX Text

CHECKED BY:

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text

DATE:

AutoCAD SHX Text

EAF

AutoCAD SHX Text

JLS

AutoCAD SHX Text 09-08-26

AutoCAD SHX Text

EA26-28

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

BICENTENNIAL PARK ROOF REPLACEMENTS

AutoCAD SHX Text

PAVILION A

AutoCAD SHX Text

EAST ALLEN TOWNSHIP NORTHAMPTON COUNTY PENNSYLVANIA

AutoCAD SHX Text

NOTED

AutoCAD SHX Text SCOPE OF WORK FOR PAVILION A: : DEMOLITION: 1. REMOVE EXISTING ASPHALT ROOF SHINGLES AND FELT PAPER. REMOVE EXISTING ASPHALT ROOF SHINGLES AND FELT PAPER. 2. REMOVE EXISTING DRIP EDGE AT EAVE AND RAKE EDGES OF ROOF. REMOVE EXISTING DRIP EDGE AT EAVE AND RAKE EDGES OF ROOF. 3. REMOVE ANY DETERIORATED PLYWOOD ROOF DECKING. REMOVE ANY DETERIORATED PLYWOOD ROOF DECKING. 4. REMOVE EXISTING LOUVERED GABLE VENT AT NORTH ELEVATION AND AT SECTION A, REST ROOM REMOVE EXISTING LOUVERED GABLE VENT AT NORTH ELEVATION AND AT SECTION A, REST ROOM END OF BUILDING. INSTALLATION: 1. REPLACE ANY DETERIORATED CDX PLYWOOD ROOF DECKING. REPLACE ANY DETERIORATED CDX PLYWOOD ROOF DECKING. 2. INSTALL NEW METAL FASCIA ON BOTH SIDES OF PAVILION AND BOTH GABLE ENDS. INSTALL NEW METAL FASCIA ON BOTH SIDES OF PAVILION AND BOTH GABLE ENDS. 3. INSTALL NEW METAL EXTENDED EAVE DRIP EDGE ALONG EAVE AND RAKE EDGES OF ROOF. INSTALL NEW METAL EXTENDED EAVE DRIP EDGE ALONG EAVE AND RAKE EDGES OF ROOF. 4. INSTALL NEW 22 GAUGE RAISED PANEL METAL ROOF. ROOF PANELS SHALL HAVE A MINIMUM INSTALL NEW 22 GAUGE RAISED PANEL METAL ROOF. ROOF PANELS SHALL HAVE A MINIMUM NUMBER OF FASTENERS REQUIRED BY MANUFACTURER, INSTALL ROOF PANELS PER MANUFACTURERS SPECIFICATIONS. 5. INSTALL SNOW GUARDS AS SHOWN ON DRAWING. INSTALL SNOW GUARDS AS SHOWN ON DRAWING. 6. INSTALL NEW LOUVERED GABLE VENT AT NORTH ELEVATION AND AT SECTION A, REST ROOM END INSTALL NEW LOUVERED GABLE VENT AT NORTH ELEVATION AND AT SECTION A, REST ROOM END OF THE BUILDING. 7. INSTALL NEW METAL SIDING OVER EXISTING WOOD SIDING AT REST ROOM END OF BUILDING. INSTALL NEW METAL SIDING OVER EXISTING WOOD SIDING AT REST ROOM END OF BUILDING. MATERIALS: 1. REPLACEMENT DECKING TO BE 1/2" CDX PLYWOOD. REPLACEMENT DECKING TO BE 1/2" CDX PLYWOOD. 2. DRIP EDGE TO BE METAL EXTENDED EAVE DRIP EDGE. COLOR SELECTED BY OWNER. DRIP EDGE TO BE METAL EXTENDED EAVE DRIP EDGE. COLOR SELECTED BY OWNER. 3. 30 POUND FELT PAPER, BLACK ASPHALT UNDERLAYMENT, 36 INCH WIDE, OVERLAP. 30 POUND FELT PAPER, BLACK ASPHALT UNDERLAYMENT, 36 INCH WIDE, OVERLAP. 4. METAL 22 GAUGE RAISED PANEL ROOF, COLOR SELECTED BY OWNER FROM STANDARD COLORS. METAL 22 GAUGE RAISED PANEL ROOF, COLOR SELECTED BY OWNER FROM STANDARD COLORS. 5. ROOFING FASTENERS TO BE PER MANUFACTURERS SPECIFICATIONS. ROOFING FASTENERS TO BE PER MANUFACTURERS SPECIFICATIONS. 6. METAL FASCIA COLOR TO BE SELECTED BY OWNER FROM STANDARD COLORS. METAL FASCIA COLOR TO BE SELECTED BY OWNER FROM STANDARD COLORS. 7. LOUVERED GABLE VENT COLOR SELECTED BY OWNER. LOUVERED GABLE VENT COLOR SELECTED BY OWNER. 8. METAL SIDING COLOR BY OWNER FROM STANDARD COLORS.METAL SIDING COLOR BY OWNER FROM STANDARD COLORS.

AutoCAD SHX Text GENERAL NOTES: : 1. ALL WORK TO CONFORM TO UNIFORM CONSTRUCTION CODE AND ALL OTHER ADOPTED CODES SUCH ALL WORK TO CONFORM TO UNIFORM CONSTRUCTION CODE AND ALL OTHER ADOPTED CODES SUCH AS THE 2018 INTERNATIONAL BUILDING CODE. 2. CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AND EXISTING CONDITIONS BEFORE CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AND EXISTING CONDITIONS BEFORE PROCEEDING WITH ANY PHASE OF WORK. ANY DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE OWNER/ENGINEER. 3. CONTRACTOR TO REMOVE AND DISPOSE OF ALL MATERIALS AND DEBRIS FROM SITE IN A PROPER CONTRACTOR TO REMOVE AND DISPOSE OF ALL MATERIALS AND DEBRIS FROM SITE IN A PROPER MANNER. 4. SITE TO BE CLEANED AND SECURED AT THE END OF EACH DAY. SITE TO BE CLEANED AND SECURED AT THE END OF EACH DAY. 5. CONTRACTOR TO PROVIDE DEMONSTRATION TO OWNER/ENGINEER OF TYPICAL FASTENING OF METAL CONTRACTOR TO PROVIDE DEMONSTRATION TO OWNER/ENGINEER OF TYPICAL FASTENING OF METAL RAISED ROOF PANEL TO ROOF DECK. 6. THERE ARE NO RAIN GUTTERS AND DOWNSPOUT PIPES ON EXISTING PAVILION "A". THERE ARE NO RAIN GUTTERS AND DOWNSPOUT PIPES ON EXISTING PAVILION "A".

Br od he ad

R oa d, S ui te

Be th le he m , P

A

7-

.6

.5

F:

0.

1.

H an ov er En g.

co m

Be th le he m O ffi ce

AutoCAD SHX Text

SOUTH ELEVATION (LOOKING NORTH) SCALE "=1'-0"14"=1'-0"

AutoCAD SHX Text 27'-5"

AutoCAD SHX Text 1'-4"

AutoCAD SHX Text 1'-4"

AutoCAD SHX Text

OVERHANG

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

11'-11 " (REF)516" (REF)

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 2'-0"

AutoCAD SHX Text 23'-5"

AutoCAD SHX Text 2'-0"

AutoCAD SHX Text 2'-0"

AutoCAD SHX Text 2'-3 "12"

AutoCAD SHX Text 2'-0"

AutoCAD SHX Text 2'-3 "12"

AutoCAD SHX Text

EXISTING FIXTURE

AutoCAD SHX Text

EXISTING SECURITY CAMERA TO REMAIN

AutoCAD SHX Text 8'-0"

AutoCAD SHX Text

INSTALL NEW METAL FASCIA, COLOR BY OWNER

AutoCAD SHX Text 27'-5"

AutoCAD SHX Text 47'-10"

AutoCAD SHX Text 17'-11"

AutoCAD SHX Text

PLAN VIEW EXISTING PAVILION A SCALE "=1'-0"14"=1'-0"

AutoCAD SHX Text

EXISTING CMU WALL

AutoCAD SHX Text 27'-5"

AutoCAD SHX Text 1'-4"

AutoCAD SHX Text 3'-4"

AutoCAD SHX Text 4'-0"

AutoCAD SHX Text 4'-0"

AutoCAD SHX Text

OPENING

AutoCAD SHX Text 10'-1"

AutoCAD SHX Text 4'-0"

AutoCAD SHX Text 4'-0"

AutoCAD SHX Text

OPENING

AutoCAD SHX Text 3'-4"

AutoCAD SHX Text 1'-4"

AutoCAD SHX Text 2'-0"

AutoCAD SHX Text 23'-5"

AutoCAD SHX Text 2'-0"

AutoCAD SHX Text 6'-1"

AutoCAD SHX Text 2'-0"

AutoCAD SHX Text 6'-0"

AutoCAD SHX Text 2'-0"

AutoCAD SHX Text 6'-0"

AutoCAD SHX Text 2'-0"

AutoCAD SHX Text 5'-11"

AutoCAD SHX Text 2'-0"

AutoCAD SHX Text 6'-0"

AutoCAD SHX Text 2'-0"

AutoCAD SHX Text 5'-10"

AutoCAD SHX Text 2'-0"

AutoCAD SHX Text 4'-8"

AutoCAD SHX Text 1'-4"

AutoCAD SHX Text 4'-4"

AutoCAD SHX Text 4'-8"

AutoCAD SHX Text 1'-4"

AutoCAD SHX Text 4'-4"

AutoCAD SHX Text N

AutoCAD SHX Text

(REFERENCE)

AutoCAD SHX Text

PAVILION

AutoCAD SHX Text

MENS ROOM

AutoCAD SHX Text

LADIES ROOM

AutoCAD SHX Text

UTILITY ROOM

AutoCAD SHX Text

CONCESSION AREA

AutoCAD SHX Text A

AutoCAD SHX Text

AutoCAD SHX Text

EXISTING CMU PILLARS (TYP)

AutoCAD SHX Text

EXISTING CMU PILLARS (TYP)

AutoCAD SHX Text

SECTION (LOOKING SOUTH) SCALE "=1'-0"14"=1'-0"

AutoCAD SHX Text 27'-5"

AutoCAD SHX Text 1'-4"

AutoCAD SHX Text 1'-4"

AutoCAD SHX Text

OVERHANG

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

EXISTING 8" BLOCK WALL

AutoCAD SHX Text INSTALL NEW 18"x24" RECTANGULAR PVC WEATHER FILTER GABLE LOUVER VENT, COLOR TO MATCH ROOF

AutoCAD SHX Text

EXISTING SECURITY CAMERA TO REMAIN

AutoCAD SHX Text

INSTALL NEW METAL SIDING, COLOR BY OWNER

AutoCAD SHX Text A

AutoCAD SHX Text

AutoCAD SHX Text

EXISTING STEEL DOOR

AutoCAD SHX Text

EXISTING LIGHT FIXTURE TO REMAIN

AutoCAD SHX Text 4'-4"

AutoCAD SHX Text 4'-4"

AutoCAD SHX Text

EAST ELEVATION (LOOKING WEST) SCALE "=1'-0"14"=1'-0"

AutoCAD SHX Text 17'-11"

AutoCAD SHX Text

EXISTING PAVILION

AutoCAD SHX Text

EXISTING RESTROOMS

AutoCAD SHX Text 47'-10"

AutoCAD SHX Text 1 "12"

AutoCAD SHX Text 1 "12"

AutoCAD SHX Text

OVERHANG

AutoCAD SHX Text 1'-4"

AutoCAD SHX Text 1'-4"

AutoCAD SHX Text

OVERHANG

AutoCAD SHX Text INSTALL NEW 30# ASPHALT IMPREGNATED FELT OVER ENTIRE ROOF, INSTALL NEW 22 GAUGE RAISED PANEL STEEL ROOF, COLOR BY OWNER

AutoCAD SHX Text 67'-2 "12"

AutoCAD SHX Text

NOTE: : PAVILION A DOES NOT HAVE RAIN GUTTERS OR DOWNSPOUTS

AutoCAD SHX Text

EXISTING 8" BLOCK WALL

AutoCAD SHX Text

EXISTING 8" BLOCK (TYP)

AutoCAD SHX Text

INSTALL SNOW GUARDS STAGGERED, TYPICAL ON BOTH SIDES OF ROOF.

AutoCAD SHX Text

INSTALL NEW METAL FASCIA, COLOR BY OWNER

AutoCAD SHX Text A

AutoCAD SHX Text

AutoCAD SHX Text THIS DOCUMENT IS THE PROPERTY OF HANOVER ENGINEERING ASSOCIATES, INC. ANY USE OF A COPY OF THIS DOCUMENT THAT DOES NOT CONTAIN AN ORIGINAL SEAL AND SIGNATURE IS STRICTLY PROHIBITED. THIS DOCUMENT IS NOT PUBLISHED AND ALL RIGHTS ARE RESERVED BY HANOVER ENGINEERING ASSOCIATES, INC. THIS PLAN HAS BEEN SEALED WITH EITHER A RED INK SEAL OR A CRIMP SEAL. IF NEITHER APPEARS ON THIS PLAN, POSSIBLE REPRODUCTIONS OR ALTERATIONS MAY HAVE BEEN MADE WITHOUT THE APPROVAL OR KNOWLEDGE OF THE SIGNATORY.

AutoCAD SHX Text

DATE

AutoCAD SHX Text

NO.

AutoCAD SHX Text

REVISIONS

AutoCAD SHX Text

PLAN TITLE:

AutoCAD SHX Text

PROJECT TITLE:

AutoCAD SHX Text

SEAL:

AutoCAD SHX Text

OF

AutoCAD SHX Text

SHEET NO.

AutoCAD SHX Text

PROJECT NO.

AutoCAD SHX Text

DRAWN BY:

AutoCAD SHX Text

CHECKED BY:

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text

DATE:

AutoCAD SHX Text

EAF

AutoCAD SHX Text

JLS

AutoCAD SHX Text 09-08-26

AutoCAD SHX Text

EA26-28

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

BICENTENNIAL PARK ROOF REPLACEMENTS

AutoCAD SHX Text

PAVILION A

AutoCAD SHX Text

EAST ALLEN TOWNSHIP NORTHAMPTON COUNTY PENNSYLVANIA

NOTED

Br od he ad

R oa d, S ui te

Be th le he m , P

A

7-

.6

.5

F:

0.

1.

H an ov er En g.

co m

Be th le he m O ffi ce

AutoCAD SHX Text N

AutoCAD SHX Text

(REFERENCE)

AutoCAD SHX Text 48'-0"

AutoCAD SHX Text

PLAN VIEW - ROOF EXISTING PAVILION B SCALE "=1'-0"14"=1'-0"

AutoCAD SHX Text 20'-0"

AutoCAD SHX Text 2'-0"

AutoCAD SHX Text 2'-0"

AutoCAD SHX Text

OVERHANG

AutoCAD SHX Text 2'-0"

AutoCAD SHX Text 2'-0"

AutoCAD SHX Text

OVERHANG

AutoCAD SHX Text 52'-0"

AutoCAD SHX Text 2'-0"

AutoCAD SHX Text 2'-0"

AutoCAD SHX Text

OVERHANG

AutoCAD SHX Text 24'-0"

AutoCAD SHX Text

ROOF RIDGE

AutoCAD SHX Text RETAIN EXISTING PLYWOOD ROOF DECKING, REPLACE DETERIORATED ROOF DECKING AS REQUIRED.

AutoCAD SHX Text 2'-0"

AutoCAD SHX Text 2'-0"

AutoCAD SHX Text

OVERHANG

AutoCAD SHX Text

INSTALL NEW METAL FASCIA, COLOR BY OWNER (TYP)

AutoCAD SHX Text INSTALL NEW 30# ASPHALT IMPREGNATED FELT OVER ENTIRE ROOF, INSTALL 1300 SQUARE FOOT OF NEW 22 GAUGE RAISED PANEL ROOF, COLOR BY OWNER

AutoCAD SHX Text

SLOPE

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

SLOPE

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

NEW 22 GAUGE RAISED PANEL ROOF

AutoCAD SHX Text

NEW 22 GAUGE RAISED PANEL ROOF

AutoCAD SHX Text SOUTH ELEVATION (LOOKING NORTH) NORTH ELEVATION OPPOSITE HAND SCALE "=1'-0"14"=1'-0"

AutoCAD SHX Text 2'-0"

AutoCAD SHX Text 2'-0"

AutoCAD SHX Text

OVERHANG

AutoCAD SHX Text 2'-0"

AutoCAD SHX Text 2'-0"

AutoCAD SHX Text

OVERHANG

AutoCAD SHX Text 52'-0"

AutoCAD SHX Text

NOTE: : PAVILION B DOES NOT HAVE RAIN GUTTERS OR DOWNSPOUTS

AutoCAD SHX Text

EXISTING 6X6 WOOD POSTS (TYP)

AutoCAD SHX Text INSTALL NEW 30# ASPHALT IMPREGNATED FELT OVER ENTIRE ROOF, INSTALL NEW 22 GAUGE RAISED PANEL STEEL ROOF, COLOR BY OWNER

AutoCAD SHX Text

INSTALL SNOW GUARDS STAGGERED, TYPICAL ON BOTH SIDES OF ROOF.

AutoCAD SHX Text

INSTALL NEW METAL FASCIA, COLOR BY OWNER

AutoCAD SHX Text WEST ELEVATION (LOOKING EAST) EAST ELEVATION OPPOSITE HAND SCALE "=1'-0"14"=1'-0"

AutoCAD SHX Text 20'-0"

AutoCAD SHX Text 2'-0"

AutoCAD SHX Text 2'-0"

AutoCAD SHX Text

OVERHANG

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

11'-0 " (REF)316" (REF)

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 8'-0"

AutoCAD SHX Text 19'-1"

AutoCAD SHX Text 5 "12"

AutoCAD SHX Text 5 "12"

AutoCAD SHX Text 2'-0"

AutoCAD SHX Text 2'-0"

AutoCAD SHX Text

OVERHANG

AutoCAD SHX Text

12'-5 " (REF)1516" (REF)

AutoCAD SHX Text

EXISTING 6X6 WOOD POSTS (TYP)

AutoCAD SHX Text 2'-0"

AutoCAD SHX Text 2'-3 "12"

AutoCAD SHX Text 2'-0"

AutoCAD SHX Text 2'-3 "12"

AutoCAD SHX Text

INSTALL NEW METAL FASCIA, COLOR BY OWNER

AutoCAD SHX Text THIS DOCUMENT IS THE PROPERTY OF HANOVER ENGINEERING ASSOCIATES, INC. ANY USE OF A COPY OF THIS DOCUMENT THAT DOES NOT CONTAIN AN ORIGINAL SEAL AND SIGNATURE IS STRICTLY PROHIBITED. THIS DOCUMENT IS NOT PUBLISHED AND ALL RIGHTS ARE RESERVED BY HANOVER ENGINEERING ASSOCIATES, INC. THIS PLAN HAS BEEN SEALED WITH EITHER A RED INK SEAL OR A CRIMP SEAL. IF NEITHER APPEARS ON THIS PLAN, POSSIBLE REPRODUCTIONS OR ALTERATIONS MAY HAVE BEEN MADE WITHOUT THE APPROVAL OR KNOWLEDGE OF THE SIGNATORY.

AutoCAD SHX Text

DATE

AutoCAD SHX Text

NO.

AutoCAD SHX Text

REVISIONS

AutoCAD SHX Text

PLAN TITLE:

AutoCAD SHX Text

PROJECT TITLE:

AutoCAD SHX Text

SEAL:

AutoCAD SHX Text

OF

AutoCAD SHX Text

SHEET NO.

AutoCAD SHX Text

PROJECT NO.

AutoCAD SHX Text

DRAWN BY:

AutoCAD SHX Text

CHECKED BY:

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text

DATE:

AutoCAD SHX Text

EAF

AutoCAD SHX Text

JLS

AutoCAD SHX Text 09-08-26

AutoCAD SHX Text

EA26-28

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

BICENTENNIAL PARK ROOF REPLACEMENTS

AutoCAD SHX Text

PAVILION B

AutoCAD SHX Text

EAST ALLEN TOWNSHIP NORTHAMPTON COUNTY PENNSYLVANIA

AutoCAD SHX Text

NOTED

AutoCAD SHX Text SCOPE OF WORK FOR PAVILION B: : DEMOLITION: 1. REMOVE EXISTING ASPHALT ROOF SHINGLES AND FELT PAPER. REMOVE EXISTING ASPHALT ROOF SHINGLES AND FELT PAPER. 2. REMOVE EXISTING DRIP EDGE AT EAVE AND RAKE EDGES OF ROOF. REMOVE EXISTING DRIP EDGE AT EAVE AND RAKE EDGES OF ROOF. 3. REMOVE ANY DETERIORATED PLYWOOD ROOF DECKING. REMOVE ANY DETERIORATED PLYWOOD ROOF DECKING. INSTALLATION: 1. REPLACE ANY DETERIORATED CDX PLYWOOD ROOF DECKING. REPLACE ANY DETERIORATED CDX PLYWOOD ROOF DECKING. 2. INSTALL NEW METAL FASCIA. INSTALL NEW METAL FASCIA. 3. INSTALL NEW EXTENDED EAVE DRIP EDGE ALONG EAVE AND RAKE EDGES OF ROOF. INSTALL NEW EXTENDED EAVE DRIP EDGE ALONG EAVE AND RAKE EDGES OF ROOF. 4. INSTALL NEW 22 GAUGE RAISED PANEL METAL ROOF. ROOF PANELS SHALL HAVE A MINIMUM INSTALL NEW 22 GAUGE RAISED PANEL METAL ROOF. ROOF PANELS SHALL HAVE A MINIMUM NUMBER OF FASTENERS REQUIRED BY MANUFACTURER, INSTALL ROOF PANELS PER MANUFACTURERS SPECIFICATIONS. 5. INSTALL SNOW GUARDS AS SHOWN ON DRAWING. INSTALL SNOW GUARDS AS SHOWN ON DRAWING. MATERIALS: 1. REPLACEMENT DECKING TO BE 1/2" CDX PLYWOOD. REPLACEMENT DECKING TO BE 1/2" CDX PLYWOOD. 2. DRIP EDGE TO BE METAL EXTENDED EAVE DRIP EDGE. COLOR SELECTED BY OWNER. DRIP EDGE TO BE METAL EXTENDED EAVE DRIP EDGE. COLOR SELECTED BY OWNER. 3. 30 POUND FELT PAPER, BLACK ASPHALT UNDERLAYMENT, 36 INCH WIDE, OVERLAP. 30 POUND FELT PAPER, BLACK ASPHALT UNDERLAYMENT, 36 INCH WIDE, OVERLAP. 4. METAL 22 GAUGE RAISED PANEL ROOF, COLOR SELECTED BY OWNER FROM STANDARD COLORS. METAL 22 GAUGE RAISED PANEL ROOF, COLOR SELECTED BY OWNER FROM STANDARD COLORS. 5. ROOFING FASTENERS TO BE PER MANUFACTURERS SPECIFICATIONS. ROOFING FASTENERS TO BE PER MANUFACTURERS SPECIFICATIONS. 6. METAL FASCIA, COLOR TO BE SELECTED BY OWNER FROM STANDARD COLORS.METAL FASCIA, COLOR TO BE SELECTED BY OWNER FROM STANDARD COLORS.

GENERAL NOTES: : 1. ALL WORK TO CONFORM TO UNIFORM CONSTRUCTION CODE AND ALL OTHER ADOPTED CODES SUCH ALL WORK TO CONFORM TO UNIFORM CONSTRUCTION CODE AND ALL OTHER ADOPTED CODES SUCH AS THE 2018 INTERNATIONAL BUILDING CODE. 2. CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AND EXISTING CONDITIONS BEFORE CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AND EXISTING CONDITIONS BEFORE PROCEEDING WITH ANY PHASE OF WORK. ANY DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE OWNER/ENGINEER. 3. CONTRACTOR TO REMOVE AND DISPOSE OF ALL MATERIALS AND DEBRIS FROM SITE IN A PROPER CONTRACTOR TO REMOVE AND DISPOSE OF ALL MATERIALS AND DEBRIS FROM SITE IN A PROPER MANNER. 4. SITE TO BE CLEANED AND SECURED AT THE END OF EACH DAY. SITE TO BE CLEANED AND SECURED AT THE END OF EACH DAY. 5. CONTRACTOR TO PROVIDE DEMONSTRATION TO OWNER/ENGINEER OF TYPICAL FASTENING OF METAL CONTRACTOR TO PROVIDE DEMONSTRATION TO OWNER/ENGINEER OF TYPICAL FASTENING OF METAL RAISED ROOF PANEL TO ROOF DECK. 6. THERE ARE NO RAIN GUTTERS AND DOWNSPOUT PIPES ON EXISTING PAVILION "B". THERE ARE NO RAIN GUTTERS AND DOWNSPOUT PIPES ON EXISTING PAVILION "B".

Br od he ad

R oa d, S ui te

Be th le he m , P

A

7-

.6

.5

F:

0.

1.

H an ov er En g.

co m

Be th le he m O ffi ce

AutoCAD SHX Text N

AutoCAD SHX Text

(REFERENCE)

AutoCAD SHX Text 35'-5"

AutoCAD SHX Text

PLAN VIEW - ROOF EXISTING RESTROOM BUILDING SCALE "=1'-0"14"=1'-0"

AutoCAD SHX Text 19'-4 "12"

AutoCAD SHX Text 1'-1"

AutoCAD SHX Text 1'-1"

AutoCAD SHX Text

OVERHANG

AutoCAD SHX Text 1'-0"

AutoCAD SHX Text 1'-0"

AutoCAD SHX Text

OVERHANG

AutoCAD SHX Text 37'-5"

AutoCAD SHX Text 1'-1"

AutoCAD SHX Text 1'-1"

AutoCAD SHX Text

OVERHANG

AutoCAD SHX Text 21'-6 "12"

AutoCAD SHX Text

SLOPE

AutoCAD SHX Text

SLOPE

AutoCAD SHX Text

AutoCAD SHX Text 3 3/4

AutoCAD SHX Text

AutoCAD SHX Text

ROOF RIDGE

AutoCAD SHX Text INSTALL NEW 30# ASPHALT IMPREGNATED FELT OVER ENTIRE ROOF, INSTALL 850 SQUARE FOOT OF NEW 22 GAUGE RAISED PANEL ROOF, COLOR BY OWNER

AutoCAD SHX Text RETAIN EXISTING PLYWOOD ROOF DECKING, REPLACE DETERIORATED ROOF DECKING AS REQUIRED.

AutoCAD SHX Text 1'-0"

AutoCAD SHX Text 1'-0"

AutoCAD SHX Text

OVERHANG

AutoCAD SHX Text 3 3/4

AutoCAD SHX Text

EXISTING PLUMBING VENT STACK

AutoCAD SHX Text

NEW 22 GAUGE RAISED PANEL ROOF

AutoCAD SHX Text

NEW 22 GAUGE RAISED PANEL ROOF

AutoCAD SHX Text

INSTALL NEW METAL FASCIA, COLOR BY OWNER (TYP)

AutoCAD SHX Text

WEST ELEVATION (LOOKING EAST) SCALE "=1'-0"14"=1'-0"

AutoCAD SHX Text 1'-0"

AutoCAD SHX Text 1'-0"

AutoCAD SHX Text

OVERHANG

AutoCAD SHX Text 1'-0"

AutoCAD SHX Text 1'-0"

AutoCAD SHX Text

OVERHANG

AutoCAD SHX Text

EXISTING 8" BLOCK WALL

AutoCAD SHX Text

NOTE: : RESTROOM BUILDING DOES NOT HAVE RAIN GUTTERS OR DOWNSPOUTS

AutoCAD SHX Text

INSTALL NEW METAL FASCIA AND SOFFIT (TYP)

AutoCAD SHX Text 37'-5"

AutoCAD SHX Text

EXISTING PLUMBING VENT STACK

AutoCAD SHX Text INSTALL NEW 30# ASPHALT IMPREGNATED FELT OVER ENTIRE ROOF, INSTALL NEW 22 GAUGE RAISED PANEL STEEL ROOF, COLOR BY OWNER

AutoCAD SHX Text

INSTALL SNOW GUARDS STAGGERED, TYPICAL ON BOTH SIDES OF ROOF.

AutoCAD SHX Text

INSTALL NEW METAL FASCIA AND SOFFIT, COLOR BY OWNER (TYP)

AutoCAD SHX Text

NORTH ELEVATION (LOOKING SOUTH) SCALE "=1'-0"14"=1'-0"

AutoCAD SHX Text 19'-4 "12"

AutoCAD SHX Text 1'-1"

AutoCAD SHX Text 1'-1"

AutoCAD SHX Text

OVERHANG

AutoCAD SHX Text 1'-1"

AutoCAD SHX Text 1'-1"

AutoCAD SHX Text

OVERHANG

AutoCAD SHX Text

EXISTING 8" BLOCK WALL

AutoCAD SHX Text

AutoCAD SHX Text 3 3/4

AutoCAD SHX Text

11'-10 " (REF)14" (REF)

AutoCAD SHX Text

AutoCAD SHX Text 3 3/4

AutoCAD SHX Text

11'-3 " (REF)58" (REF)

AutoCAD SHX Text

EXISTING PLUMBING VENT STACK

AutoCAD SHX Text

INSTALL NEW METAL FASCIA AND SOFFIT, COLOR BY OWNER (TYP)

AutoCAD SHX Text 2'-0"

AutoCAD SHX Text 1'-6"

AutoCAD SHX Text INSTALL NEW 18"x24" RECTANGULAR PVC WEATHER FILTER GABLE LOUVER VENT, COLOR TO MATCH ROOF. TYPICAL BOTH GABLE ENDS.

AutoCAD SHX Text

INSTALL NEW METAL SIDING, COLOR BY OWNER

AutoCAD SHX Text

SOUTH ELEVATION (LOOKING NORTH) SCALE "=1'-0"14"=1'-0"

AutoCAD SHX Text 19'-4 "12"

AutoCAD SHX Text 1'-1"

AutoCAD SHX Text 1'-1"

AutoCAD SHX Text

OVERHANG

AutoCAD SHX Text 1'-1"

AutoCAD SHX Text 1'-1"

AutoCAD SHX Text

OVERHANG

AutoCAD SHX Text

EXISTING 8" BLOCK WALL

AutoCAD SHX Text

AutoCAD SHX Text 3 3/4

AutoCAD SHX Text

AutoCAD SHX Text 3 3/4

AutoCAD SHX Text

EXISTING PLUMBING VENT STACK

AutoCAD SHX Text

INSTALL NEW METAL FASCIA AND SOFFIT (TYP)

AutoCAD SHX Text

INSTALL NEW METAL SIDING, COLOR BY OWNER

AutoCAD SHX Text INSTALL NEW 18"x24" RECTANGULAR PVC WEATHER FILTER GABLE LOUVER VENT, COLOR TO MATCH ROOF. TYPICAL BOTH GABLE ENDS.

AutoCAD SHX Text

EAST ELEVATION (LOOKING WEST) SCALE "=1'-0"14"=1'-0"

AutoCAD SHX Text 1'-0"

AutoCAD SHX Text 1'-0"

AutoCAD SHX Text

OVERHANG

AutoCAD SHX Text 1'-0"

AutoCAD SHX Text 1'-0"

AutoCAD SHX Text

OVERHANG

AutoCAD SHX Text

EXISTING 8" BLOCK WALL

AutoCAD SHX Text

NOTE: : RESTROOM BUILDING DOES NOT HAVE RAIN GUTTERS OR DOWNSPOUTS

AutoCAD SHX Text

INSTALL NEW METAL FASCIA AND SOFFIT (TYP)

AutoCAD SHX Text 37'-5"

AutoCAD SHX Text INSTALL NEW 30# ASPHALT IMPREGNATED FELT OVER ENTIRE ROOF, INSTALL NEW 22 GAUGE RAISED PANEL STEEL ROOF, COLOR BY OWNER

AutoCAD SHX Text

INSTALL SNOW GUARDS STAGGERED, TYPICAL ON BOTH SIDES OF ROOF.

AutoCAD SHX Text

INSTALL NEW METAL FASCIA AND SOFFIT, COLOR BY OWNER (TYP)

AutoCAD SHX Text

EXISTING 8" BLOCK WALL

AutoCAD SHX Text THIS DOCUMENT IS THE PROPERTY OF HANOVER ENGINEERING ASSOCIATES, INC. ANY USE OF A COPY OF THIS DOCUMENT THAT DOES NOT CONTAIN AN ORIGINAL SEAL AND SIGNATURE IS STRICTLY PROHIBITED. THIS DOCUMENT IS NOT PUBLISHED AND ALL RIGHTS ARE RESERVED BY HANOVER ENGINEERING ASSOCIATES, INC. THIS PLAN HAS BEEN SEALED WITH EITHER A RED INK SEAL OR A CRIMP SEAL. IF NEITHER APPEARS ON THIS PLAN, POSSIBLE REPRODUCTIONS OR ALTERATIONS MAY HAVE BEEN MADE WITHOUT THE APPROVAL OR KNOWLEDGE OF THE SIGNATORY.

AutoCAD SHX Text

DATE

AutoCAD SHX Text

NO.

AutoCAD SHX Text

REVISIONS

AutoCAD SHX Text

PLAN TITLE:

AutoCAD SHX Text

PROJECT TITLE:

AutoCAD SHX Text

SEAL:

AutoCAD SHX Text

OF

AutoCAD SHX Text

SHEET NO.

AutoCAD SHX Text

PROJECT NO.

AutoCAD SHX Text

DRAWN BY:

AutoCAD SHX Text

CHECKED BY:

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text

DATE:

AutoCAD SHX Text

EAF

AutoCAD SHX Text

JLS

AutoCAD SHX Text 09-08-26

AutoCAD SHX Text

EA26-28

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

BICENTENNIAL PARK ROOF REPLACEMENTS

AutoCAD SHX Text

RESTROOM BUILDING

AutoCAD SHX Text

EAST ALLEN TOWNSHIP NORTHAMPTON COUNTY PENNSYLVANIA

AutoCAD SHX Text

NOTED

AutoCAD SHX Text SCOPE OF WORK FOR RESTROOM: : DEMOLITION: 1. REMOVE EXISTING ASPHALT ROOF SHINGLES AND FELT PAPER. REMOVE EXISTING ASPHALT ROOF SHINGLES AND FELT PAPER. 2. REMOVE EXISTING DRIP EDGE AT EAVE AND RAKE EDGES OF ROOF. REMOVE EXISTING DRIP EDGE AT EAVE AND RAKE EDGES OF ROOF. 3. REMOVE EXISTING FLASHING AT PLUMBING VENT STACK. REMOVE EXISTING FLASHING AT PLUMBING VENT STACK. 4. REMOVE ANY DETERIORATED PLYWOOD ROOF DECKING. REMOVE ANY DETERIORATED PLYWOOD ROOF DECKING. 5. REMOVE EXISTING FASCIA AND SOFFIT. REMOVE EXISTING FASCIA AND SOFFIT. 6. REMOVE EXISTING LOUVERED GABLE VENT AT EACH END OF BUILDING. REMOVE EXISTING LOUVERED GABLE VENT AT EACH END OF BUILDING. INSTALLATION: 1. REPLACE ANY DETERIORATED CDX PLYWOOD ROOF DECKING. REPLACE ANY DETERIORATED CDX PLYWOOD ROOF DECKING. 2. INSTALL NEW METAL FASCIA AND SOFFIT. INSTALL NEW METAL FASCIA AND SOFFIT. 3. INSTALL NEW METAL EXTENDED EAVE DRIP EDGE ALONG EAVE AND RAKE EDGES OF ROOF. INSTALL NEW METAL EXTENDED EAVE DRIP EDGE ALONG EAVE AND RAKE EDGES OF ROOF. 4. INSTALL NEW FLASHING AT PLUMBING VENT STACK. INSTALL NEW FLASHING AT PLUMBING VENT STACK. 5. INSTALL NEW 22 GAUGE RAISED PANEL METAL ROOF. ROOF PANELS SHALL HAVE A MINIMUM INSTALL NEW 22 GAUGE RAISED PANEL METAL ROOF. ROOF PANELS SHALL HAVE A MINIMUM NUMBER OF FASTENERS REQUIRED BY MANUFACTURER, INSTALL ROOF PANELS PER MANUFACTURERS SPECIFICATIONS. 6. INSTALL SNOW GUARDS AS SHOWN ON DRAWING. INSTALL SNOW GUARDS AS SHOWN ON DRAWING. 7. INSTALL NEW LOUVERED GABLE VENT AT EACH END OF THE BUILDING. INSTALL NEW LOUVERED GABLE VENT AT EACH END OF THE BUILDING. 8. INSTALL NEW METAL SIDING OVER EXISTING WOOD SIDING. INSTALL NEW METAL SIDING OVER EXISTING WOOD SIDING. MATERIALS: 1. REPLACEMENT DECKING TO BE 1/2" CDX PLYWOOD. REPLACEMENT DECKING TO BE 1/2" CDX PLYWOOD. 2. DRIP EDGE TO BE METAL EXTENDED EAVE DRIP EDGE. COLOR SELECTED BY OWNER. DRIP EDGE TO BE METAL EXTENDED EAVE DRIP EDGE. COLOR SELECTED BY OWNER. 3. 30 POUND FELT PAPER, BLACK ASPHALT UNDERLAYMENT, 36 INCH WIDE, OVERLAP. 30 POUND FELT PAPER, BLACK ASPHALT UNDERLAYMENT, 36 INCH WIDE, OVERLAP. 4. METAL 22 GAUGE RAISED PANEL ROOF, COLOR SELECTED BY OWNER FROM STANDARD COLORS. METAL 22 GAUGE RAISED PANEL ROOF, COLOR SELECTED BY OWNER FROM STANDARD COLORS. 5. ROOFING FASTENERS TO BE PER MANUFACTURERS SPECIFICATIONS. ROOFING FASTENERS TO BE PER MANUFACTURERS SPECIFICATIONS. 6. METAL FASCIA AND SOFFIT, COLOR TO BE SELECTED BY OWNER FROM STANDARD COLORS. METAL FASCIA AND SOFFIT, COLOR TO BE SELECTED BY OWNER FROM STANDARD COLORS. 7. LOUVERED GABLE VENT, COLOR SELECTED BY OWNER. LOUVERED GABLE VENT, COLOR SELECTED BY OWNER. 8. METAL SIDING, COLOR BY OWNER FROM STANDARD COLORS.METAL SIDING, COLOR BY OWNER FROM STANDARD COLORS.

GENERAL NOTES: : 1. ALL WORK TO CONFORM TO UNIFORM CONSTRUCTION CODE AND ALL OTHER ADOPTED CODES SUCH ALL WORK TO CONFORM TO UNIFORM CONSTRUCTION CODE AND ALL OTHER ADOPTED CODES SUCH AS THE 2018 INTERNATIONAL BUILDING CODE. 2. CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AND EXISTING CONDITIONS BEFORE CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AND EXISTING CONDITIONS BEFORE PROCEEDING WITH ANY PHASE OF WORK. ANY DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE OWNER/ENGINEER. 3. CONTRACTOR TO REMOVE AND DISPOSE OF ALL MATERIALS AND DEBRIS FROM SITE IN A PROPER CONTRACTOR TO REMOVE AND DISPOSE OF ALL MATERIALS AND DEBRIS FROM SITE IN A PROPER MANNER. 4. SITE TO BE CLEANED AND SECURED AT THE END OF EACH DAY. SITE TO BE CLEANED AND SECURED AT THE END OF EACH DAY. 5. CONTRACTOR TO PROVIDE DEMONSTRATION TO OWNER/ENGINEER OF TYPICAL FASTENING OF METAL CONTRACTOR TO PROVIDE DEMONSTRATION TO OWNER/ENGINEER OF TYPICAL FASTENING OF METAL RAISED ROOF PANEL TO ROOF DECK. 6. THERE ARE NO RAIN GUTTERS AND DOWNSPOUT PIPES ON EXISTING RESTROOM BUILDING. THERE ARE NO RAIN GUTTERS AND DOWNSPOUT PIPES ON EXISTING RESTROOM BUILDING.

Br od he ad

R oa d, S ui te

Be th le he m , P

A

7-

.6

.5

F:

0.

1.

H an ov er En g.

co m

Be th le he m O ffi ce

AutoCAD SHX Text

WEST ELEVATION (LOOKING EAST) SCALE "=1'-0"14"=1'-0"

AutoCAD SHX Text

EXISTING BUILDING

AutoCAD SHX Text

CONTINUOUS RIDGE VENT

AutoCAD SHX Text

13'-11 " (REFERENCE)12" (REFERENCE)

AutoCAD SHX Text 42'-0"

AutoCAD SHX Text

EXISTING BUILDING

AutoCAD SHX Text

INSTALL SNOW GUARDS STAGGERED, TYPICAL ON BOTH SIDES OF ROOF.

AutoCAD SHX Text

EXISTING BLOCK WALL

AutoCAD SHX Text

EXISTING DOOR

AutoCAD SHX Text

NORTH ELEVATION (LOOKING SOUTH) SCALE "=1'-0"14"=1'-0"

AutoCAD SHX Text

FINISHED GRADE ELEVATIONS TO BE DETERMINED IN THE FIELD BY CONTRACTOR

AutoCAD SHX Text 24'-0"

AutoCAD SHX Text 2'-0"

AutoCAD SHX Text 2'-0"

AutoCAD SHX Text

OVERHANG

AutoCAD SHX Text 2'-0"

AutoCAD SHX Text 2'-0"

AutoCAD SHX Text

OVERHANG

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 3'-0"

AutoCAD SHX Text 2'-0"

AutoCAD SHX Text 3'-0"

AutoCAD SHX Text 2'-0"

AutoCAD SHX Text

INSTALL NEW METAL SIDING, COLOR BY OWNER

AutoCAD SHX Text INSTALL NEW 18"x24" RECTANGULAR PVC WEATHER FILTER GABLE LOUVER VENT, COLOR TO MATCH ROOF

AutoCAD SHX Text

INSTALL NEW METAL FASCIA, COLOR BY OWNER

AutoCAD SHX Text

15'-2 " (REFERENCE)316" (REFERENCE)

AutoCAD SHX Text

EXISTING BLOCK WALL

AutoCAD SHX Text

EXISTING OVERHEAD DOOR

AutoCAD SHX Text

INSTALL NEW METAL SOFFIT, COLOR BY OWNER

AutoCAD SHX Text

FINISHED GRADE ELEVATIONS TO BE DETERMINED IN THE FIELD BY CONTRACTOR

AutoCAD SHX Text 24'-0"

AutoCAD SHX Text 8'-0"

AutoCAD SHX Text 2'-0"

AutoCAD SHX Text 2'-0"

AutoCAD SHX Text

OVERHANG

AutoCAD SHX Text 2'-0"

AutoCAD SHX Text 2'-0"

AutoCAD SHX Text

OVERHANG

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 3'-0"

AutoCAD SHX Text 2'-0"

AutoCAD SHX Text 3'-0"

AutoCAD SHX Text 2'-0"

AutoCAD SHX Text

INSTALL NEW METAL SIDING, COLOR BY OWNER

AutoCAD SHX Text INSTALL NEW 18"x24" RECTANGULAR PVC WEATHER FILTER GABLE LOUVER VENT, COLOR TO MATCH ROOF

AutoCAD SHX Text

INSTALL NEW METAL FASCIA, COLOR BY OWNER

AutoCAD SHX Text

15'-2 " (REFERENCE)316" (REFERENCE)

AutoCAD SHX Text

INSTALL NEW METAL SOFFIT, COLOR BY OWNER

AutoCAD SHX Text

SOUTH ELEVATION (LOOKING NORTH) SCALE "=1'-0"14"=1'-0"

AutoCAD SHX Text

EAST ELEVATION (LOOKING WEST) SCALE "=1'-0"14"=1'-0"

AutoCAD SHX Text

EXISTING BUILDING

AutoCAD SHX Text

13'-11 " (REFERENCE)12" (REFERENCE)

AutoCAD SHX Text 42'-0"

AutoCAD SHX Text

EXISTING BUILDING

AutoCAD SHX Text

CONTINUOUS RIDGE VENT

AutoCAD SHX Text

INSTALL SNOW GUARDS STAGGERED, TYPICAL ON BOTH SIDES OF ROOF.

AutoCAD SHX Text 42'-0"

AutoCAD SHX Text

MAINTENANCE BUILDING - ROOF VIEW SCALE "=1'-0"14"=1'-0"

AutoCAD SHX Text

EXISTING BUILDING

AutoCAD SHX Text A

AutoCAD SHX Text

AutoCAD SHX Text A

AutoCAD SHX Text

AutoCAD SHX Text

INSTALL NEW VINYL VENTED SOFFIT AND ALUMINUM GUTTER

AutoCAD SHX Text

INSTALL NEW VINYL VENTED SOFFIT AND ALUMINUM GUTTER

AutoCAD SHX Text N

AutoCAD SHX Text

(REFERENCE)

AutoCAD SHX Text

5/12 ROOF SLOPE

AutoCAD SHX Text

5/12 ROOF SLOPE

AutoCAD SHX Text

FIELD VERIFY EXISTING ROOF SLOPE

AutoCAD SHX Text

FIELD VERIFY EXISTING ROOF SLOPE

AutoCAD SHX Text INSTALL NEW 30# ASPHALT IMPREGNATED FELT OVER ENTIRE ROOF, INSTALL 2100 SQUARE FOOT OF NEW 22 GAUGE RAISED PANEL ROOF, COLOR BY OWNER

AutoCAD SHX Text 1 "12"

AutoCAD SHX Text 1 "12"

AutoCAD SHX Text

OVERHANG

AutoCAD SHX Text

CONTINUOUS RIDGE VENT

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

EXISTING PRE-ENGINEERED ROOF TRUSS

AutoCAD SHX Text NEW 2x4 NAILER

AutoCAD SHX Text

NEW METAL FASCIA

AutoCAD SHX Text

EXISTING CMU WALL

AutoCAD SHX Text

NEW METAL VENTED SOFFIT

AutoCAD SHX Text

SECTION SCALE "=1'-0"12"=1'-0"

AutoCAD SHX Text A

AutoCAD SHX Text

AutoCAD SHX Text

NEW METAL DRIP EDGE

AutoCAD SHX Text THIS DOCUMENT IS THE PROPERTY OF HANOVER ENGINEERING ASSOCIATES, INC. ANY USE OF A COPY OF THIS DOCUMENT THAT DOES NOT CONTAIN AN ORIGINAL SEAL AND SIGNATURE IS STRICTLY PROHIBITED. THIS DOCUMENT IS NOT PUBLISHED AND ALL RIGHTS ARE RESERVED BY HANOVER ENGINEERING ASSOCIATES, INC. THIS PLAN HAS BEEN SEALED WITH EITHER A RED INK SEAL OR A CRIMP SEAL. IF NEITHER APPEARS ON THIS PLAN, POSSIBLE REPRODUCTIONS OR ALTERATIONS MAY HAVE BEEN MADE WITHOUT THE APPROVAL OR KNOWLEDGE OF THE SIGNATORY.

AutoCAD SHX Text

DATE

AutoCAD SHX Text

NO.

AutoCAD SHX Text

REVISIONS

AutoCAD SHX Text

PLAN TITLE:

AutoCAD SHX Text

PROJECT TITLE:

AutoCAD SHX Text

SEAL:

AutoCAD SHX Text

OF

AutoCAD SHX Text

SHEET NO.

AutoCAD SHX Text

PROJECT NO.

AutoCAD SHX Text

DRAWN BY:

AutoCAD SHX Text

CHECKED BY:

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text

DATE:

AutoCAD SHX Text

EAF

AutoCAD SHX Text

JLS

AutoCAD SHX Text 09-08-26

AutoCAD SHX Text

EA26-28

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

BICENTENNIAL PARK ROOF REPLACEMENTS

AutoCAD SHX Text

MAINTENANCE BUILDING

AutoCAD SHX Text

EAST ALLEN TOWNSHIP NORTHAMPTON COUNTY PENNSYLVANIA

AutoCAD SHX Text

NOTED

AutoCAD SHX Text GENERAL NOTES 1. THE CONSTRUCTION MUST BE PERFORMED IN STRICT ACCORDANCE WITH THE PROJECT DRAWINGS. ANY THE CONSTRUCTION MUST BE PERFORMED IN STRICT ACCORDANCE WITH THE PROJECT DRAWINGS. ANY DEVIATION FROM THE DRAWINGS MUST BE APPROVED IN WRITING BY THE ENGINEER. ERRORS AND/OR OMISSIONS FOUND ON THE DRAWING MUST BE BROUGHT TO THE ENGINEER'S ATTENTION IMMEDIATELY. 2. THE ENGINEER IS NOT RESPONSIBLE FOR, AND WILL NOT HAVE CONTROL OF THE CONSTRUCTION MEANS, THE ENGINEER IS NOT RESPONSIBLE FOR, AND WILL NOT HAVE CONTROL OF THE CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, OR PROCEDURES, OR FOR SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH THE CONSTRUCTION WORK, NOR WILL THE ENGINEER BE RESPONSIBLE FOR THE CONTRACTOR'S FAILURE TO CARRY OUT THE CONSTRUCTION WORK IN ACCORDANCE WITH THE CONTRACT DOCUMENTS. 3. CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS, DIMENSIONS, AND ELEVATIONS IN THE FIELD CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS, DIMENSIONS, AND ELEVATIONS IN THE FIELD BEFORE ORDERING ANY MATERIALS, OR STARTING ANY WORK. CONFLICTS BETWEEN FIELD CONDITIONS AND CONTRACT DRAWINGS SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER IMMEDIATELY. 4. ALL WORK TO CONFORM TO UNIFORM CONSTRUCTION CODE AND ALL OTHER ADOPTED CODES ALL WORK TO CONFORM TO UNIFORM CONSTRUCTION CODE AND ALL OTHER ADOPTED CODES SUCH AS THE INTERNATIONAL BUILDING CODE, 2018 INTERNATIONAL BUILDING CODE. 5. ROOF SHEATHING SHALL BE 1/2" CDX PLYWOOD A.P.A. RATED. ROOF SHEATHING SHALL BE 1/2" CDX PLYWOOD A.P.A. RATED.

SCOPE OF WORK: : 1. ROOF REPLACEMENT OF EXISTING PARK MAINTENANCE ROOF REPLACEMENT OF EXISTING PARK MAINTENANCE BUILDING, CONSISTING OF THE FOLLOWING: REMOVE EXISTING ASPHALT SHINGLES, DRIP EDGE, FASCIA AND SOFFITS. REMOVE ANY EXISTING DETERIORATED ROOF SHEATHING, AS REQUIRED. REMOVE EXISTING GABLE VENTS AT EACH END OF BUILDING. INSTALL NEW PLYWOOD SHEATHING ON EXISTING BUILDING, AS REQUIRED. INSTALL NEW 30# FELT PAPER OVER ENTIRE ROOF. INSTALL NEW METAL DRIP EDGE. INSTALL NEW METAL RAISED SEAM METAL ROOF WITH CONTINUOUS RIDGE VENT. INSTALLATION OF METAL FASCIA AND SOFFITS. INSTALLATION OF NEW GABLE VENTS, EACH END OF BUILDING.

File details come from the government source that posted it. Updated .