2-02 BicentennialParkPavilionCStructural 20260908.pdf
PDF 5 MB Posted
- Solicitation number
- US.260327
- Issued by
- Northampton County, Pennsylvania
About this file
This is a structural plan document prepared by Hanover Engineering Associates, Inc. for East Allen Township, Northampton County, Pennsylvania, detailing the construction specifications for Bicentennial Park Pavilion C. The project involves the removal and replacement of Pavilion C and roof replacements for Pavilions A and B, the Restroom Building, and the Maintenance Building. The pavilion structure is designed as an open-air assembly facility measuring 80 feet by 40 feet with a maximum occupant load of 213 people, classified as Assembly Group A-2 under the 2018 International Building Code with Type VB construction. The pavilion features a 4/12 roof slope with engineered roof trusses, 8x8 pressure-treated wood posts with concrete foundations, and a 6-inch thick poured concrete floor with welded wire reinforcement. Proposals will be received online through PennBid until 1:00 p.m. prevailing time on December 3, 2026, with public opening at Hanover Engineering Associates' office in Bethlehem, Pennsylvania. A non-mandatory pre-bid conference is scheduled for November 17, 2026 at 2:00 p.m. at Pavilion B Parking Lot, with final questions due by 4:00 p.m. on November 24, 2026.
The project requires compliance with Pennsylvania's prevailing wage requirements under the Act of August 15, 1961, and all subcontractors must adhere to these wage provisions. A bid bond or acceptable security in the amount of 10 percent of the total Base Bid is required with proposal submission. Bids will remain effective for 60 calendar days from the opening date and cannot be withdrawn during this period. Bidders must submit bids on all items listed on the Bid Form. The structural plans specify materials including pressure-treated structural lumber rated UC3B for exterior use and UC4B for ground contact, with a maximum moisture content of 19 percent. Concrete is specified at 4,000 psi minimum compressive strength at 28 days, and all roof trusses must be engineered by the manufacturer and sealed by a registered Pennsylvania engineer. The complete bidding documents, including contract forms, specifications, and drawings, are available through the project page at https://pennbid.bonfirehub.com.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Br od he ad
R oa d, S ui te
Be th le he m , P
A
7-
P :6
.6
.5
F:
0.
1.
H an ov er En g.
co m
Be th le he m O ffi ce
LOCATION MAP
SCALE: N.T.S.
SOURCE: CATASAUQUA USGS
AutoCAD SHX Text
CONTINUOUS RIDGE VENT
AutoCAD SHX Text
22 GAUGE STEEL ROOF
AutoCAD SHX Text
EAST ELEVATION (LOOKING WEST) SCALE "=1'-0"14"=1'-0"
AutoCAD SHX Text 80'-0"
AutoCAD SHX Text 3 "58"
AutoCAD SHX Text
7 " (TYP)14" (TYP)
AutoCAD SHX Text 79'-4 "34"
AutoCAD SHX Text 3 "58"
AutoCAD SHX Text 7'-0"
AutoCAD SHX Text 6x6 P.T. KNEE BRACE
AutoCAD SHX Text 8x8 P.T. WOOD POST
AutoCAD SHX Text 2'-10"
AutoCAD SHX Text 2'-10"
AutoCAD SHX Text 4'-0"
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
INSTALL SNOW GUARDS STAGGERED, TYPICAL ON BOTH SIDES OF ROOF.
AutoCAD SHX Text
SEE CIVIL DWGS FOR CONCRETE WALKWAY INFO
AutoCAD SHX Text
SEE CIVIL DWGS FOR CONCRETE WALKWAY INFO
AutoCAD SHX Text 9'-11 "332"
AutoCAD SHX Text 9'-11 "332"
AutoCAD SHX Text 9'-11 "332"
AutoCAD SHX Text 9'-11 "332"
AutoCAD SHX Text 9'-11 "332"
AutoCAD SHX Text 9'-11 "332"
AutoCAD SHX Text 9'-11 "332"
AutoCAD SHX Text 9'-11 "332"
AutoCAD SHX Text INSTALL 24"x30" (MIN) ACCESS PANEL BETWEEN CEILING JOISTS
AutoCAD SHX Text
AutoCAD SHX Text FOLLOWING INFORMATION FROM 2018 INTERNATIONAL BUILDING CODE: : 1. OCCUPANCY CLASSIFICATION SECTION 303.3 ASSEMBLY GROUP A-2. OCCUPANCY CLASSIFICATION SECTION 303.3 ASSEMBLY GROUP A-2. 2. CONSTRUCTION TYPE SECTION 602, TABLE 601 TYPE VB. CONSTRUCTION TYPE SECTION 602, TABLE 601 TYPE VB. 3. OCCUPANT LOAD SECTION 1004.1.2, TABLE 1004.1.2 ASSEMBLY AREAS WITHOUT OCCUPANT LOAD SECTION 1004.1.2, TABLE 1004.1.2 ASSEMBLY AREAS WITHOUT FIXED SEATING UNCONCENTRATED (TABLES AND CHAIRS) 15 NET. (80' x 40' = 3200 SQUARE FOOT. 3200 BY 15 NET) MAXIMUM 213 OCCUPANTS TOTAL. 4. DESIGN LOAD: DESIGN LOAD: TABLE 1607.1, ASSEMBLY AREAS 100 PSF UNIFORM LIVE LOAD.
AutoCAD SHX Text GENERAL NOTES: : 1. ALL WORK TO CONFORM TO UNIFORM CONSTRUCTION CODE AND ALL OTHER ALL WORK TO CONFORM TO UNIFORM CONSTRUCTION CODE AND ALL OTHER ADOPTED CODES SUCH AS THE INTERNATIONAL BUILDING CODE, 2018 INTERNATIONAL BUILDING CODE. 2. CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AND EXISTING CONDITIONS CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AND EXISTING CONDITIONS BEFORE PROCEEDING WITH ANY PHASE OF WORK. ANY DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE DESIGNER. 3. ALL LUMBER TO BE ACQ PRESSURE TREATED STRUCTURAL, UC3B FOR STANDARD ALL LUMBER TO BE ACQ PRESSURE TREATED STRUCTURAL, UC3B FOR STANDARD EXTERIOR USE AND UC4B FOR LUMBER IN CONTACT WITH THE GROUND. LUMBER NOT TO EXCEED A MOISTURE CONTENT OF 19%. 4. CHANGES IN LEVEL GREATER THAN INCH IN HEIGHT SHALL BE RAMPED AND SHALL CHANGES IN LEVEL GREATER THAN INCH IN HEIGHT SHALL BE RAMPED AND SHALL 12 INCH IN HEIGHT SHALL BE RAMPED AND SHALL COMPLY WITH SECTION 405 OR 406 OF THE ICC A117.1-2015 CODE. 5. GUARDS TO BE INSTALLED ON EACH SIDE OF STAIRS WITH HANDRAIL FASTENED TO GUARDS TO BE INSTALLED ON EACH SIDE OF STAIRS WITH HANDRAIL FASTENED TO GUARD POSTS. OPENING LIMITATIONS AT GUARD BALUSTRADE SHALL NOT ALLOW PASSAGE OF A SPHERE 4 INCHES IN DIAMETER TO PASS. 6. FASTENERS, NAILS AND SCREWS TO BE COMPATIBLE WITH ACQ TREATED LUMBER. FASTENERS, NAILS AND SCREWS TO BE COMPATIBLE WITH ACQ TREATED LUMBER. 7. LOADS: LOADS: ROOF LOADS = 50 P.S.F. GROUND SNOW LOAD 10 P.S.F. DEAD LOAD TOTAL = 60 P.S.F. 8. ALL ROOF TRUSS ARE DESIGNED ROOF TRUSS SYSTEM. ALL ROOF TRUSS SHALL BE ALL ROOF TRUSS ARE DESIGNED ROOF TRUSS SYSTEM. ALL ROOF TRUSS SHALL BE ENGINEERED BY THE TRUSS MANUFACTURER AND SUBMITTED TO THE BUILDER AND TOWNSHIP FOR REVIEW BEFORE TRUSS ARE MANUFACTURED. ENGINEERED ROOF TRUSS DRAWINGS MUST BE SEALED BY ENGINEER REGISTERED IN THE STATE OF PA. 9. ROOF SHEATHING SHALL BE 19/32" PLYWOOD SHEATHING A.P.A. RATED. ROOF SHEATHING SHALL BE 19/32" PLYWOOD SHEATHING A.P.A. RATED. 10. DIMENSIONS MAY NOT BE SCALED FROM DRAWINGS. DIMENSIONS MAY NOT BE SCALED FROM DRAWINGS.
AutoCAD SHX Text DRAWINGS WERE PREPARED IN ACCORDANCE WITH INTERNATIONAL CODE COUNCIL (ICC) "INTERNATIONAL BUILDING CODE 2018"
AutoCAD SHX Text
NORTH ELEVATION (LOOKING SOUTH) SCALE "=1'-0"14"=1'-0"
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 10'-0"
AutoCAD SHX Text 40'-0"
AutoCAD SHX Text
7 " (TYP)14" (TYP)
AutoCAD SHX Text
18'-2 " REFERENCE916" REFERENCE
AutoCAD SHX Text 2'-10"
AutoCAD SHX Text 2'-10"
AutoCAD SHX Text 7'-0"
AutoCAD SHX Text 4'-0"
AutoCAD SHX Text
AutoCAD SHX Text 4'-4"
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
STEEL SIDING
AutoCAD SHX Text 18"x24" RECTANGULAR PVC WEATHER FILTER GABLE LOUVER VENT, COLOR TO MATCH ROOF. TYPICAL BOTH GABLE ENDS
AutoCAD SHX Text
STEEL SIDING, TYPICAL BOTH GABLE ENDS
AutoCAD SHX Text A
AutoCAD SHX Text
AutoCAD SHX Text
WALL PACK LIGHT
AutoCAD SHX Text
SEE CIVIL DWGS FOR CONCRETE WALKWAY INFO
AutoCAD SHX Text
SEE CIVIL DWGS FOR CONCRETE WALKWAY INFO
AutoCAD SHX Text 3 "58"
AutoCAD SHX Text 3 "58"
AutoCAD SHX Text 9'-10 "316"
AutoCAD SHX Text 9'-10 "316"
AutoCAD SHX Text 9'-10 "316"
AutoCAD SHX Text 9'-10 "316"
AutoCAD SHX Text 2'-10"
AutoCAD SHX Text 2'-10"
AutoCAD SHX Text
OVERHANG
AutoCAD SHX Text
SECTION SCALE "=1'-0"14"=1'-0"
AutoCAD SHX Text
AutoCAD SHX Text
1/2" PLYWOOD WITH STEEL SIDING, TYPICAL
AutoCAD SHX Text
(3) 2x12 P.T. HEADERS2x12 P.T. HEADERS
AutoCAD SHX Text 6x6 P.T. KNEE BRACE
AutoCAD SHX Text 8x8 P.T. POST
AutoCAD SHX Text 11'-0"
AutoCAD SHX Text 18"x24" GABLE LOUVER VENT
AutoCAD SHX Text A
AutoCAD SHX Text 01/04
AutoCAD SHX Text
CONTINUOUS RIDGE VENT
AutoCAD SHX Text
SEE CIVIL DWGS FOR CONCRETE WALKWAY INFO
AutoCAD SHX Text
PROVIDE DRAG TRUSS AT END OF PAVILION; 155#/FT
AutoCAD SHX Text
SIMPSON A35 CONNECTOR @ 2'-0" OC
AutoCAD SHX Text PROVIDE 2x6 NAILER AS REQ'D ON INSIDE FACE OF PAVILION FOR KBS1Z CONNECTOR TO POST
AutoCAD SHX Text THIS DOCUMENT IS THE PROPERTY OF HANOVER ENGINEERING ASSOCIATES, INC. ANY USE OF A COPY OF THIS DOCUMENT THAT DOES NOT CONTAIN AN ORIGINAL SEAL AND SIGNATURE IS STRICTLY PROHIBITED. THIS DOCUMENT IS NOT PUBLISHED AND ALL RIGHTS ARE RESERVED BY HANOVER ENGINEERING ASSOCIATES, INC. THIS PLAN HAS BEEN SEALED WITH EITHER A RED INK SEAL OR A CRIMP SEAL. IF NEITHER APPEARS ON THIS PLAN, POSSIBLE REPRODUCTIONS OR ALTERATIONS MAY HAVE BEEN MADE WITHOUT THE APPROVAL OR KNOWLEDGE OF THE SIGNATORY.
AutoCAD SHX Text
DATE
AutoCAD SHX Text
NO.
AutoCAD SHX Text
REVISIONS
AutoCAD SHX Text
PLAN TITLE:
AutoCAD SHX Text
PROJECT TITLE:
AutoCAD SHX Text
SEAL:
AutoCAD SHX Text
OF
AutoCAD SHX Text
SHEET NO.
AutoCAD SHX Text
PROJECT NO.
AutoCAD SHX Text
DRAWN BY:
AutoCAD SHX Text
CHECKED BY:
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
EAF
AutoCAD SHX Text
TMT
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 03-12-24
AutoCAD SHX Text
AutoCAD SHX Text
ADDED 6X6 POST AND 3/4 PLYWOOD
AutoCAD SHX Text
AS NOTED
AutoCAD SHX Text 10-19-22
AutoCAD SHX Text
EA26-28
AutoCAD SHX Text
EAST ALLEN TOWNSHIP NORTHAMPTON COUNTY PENNSYLVANIA
AutoCAD SHX Text
BICENTENNIAL PARK PAVILION C STRUCTURAL PLANS
AutoCAD SHX Text
NORTH & EAST ELEVATIONS, NOTES
AutoCAD SHX Text OWNER: : EAST ALLEN TOWNSHIP 5344 NOR-BATH BOULEVARD NORTHAMPTON, PA 18067 BICENTENNIAL PARK LOCATION: : 5351 PARK WEST LANE BETHLEHEM, PA 18017
AutoCAD SHX Text
SITE LOCATION
AutoCAD SHX Text N
AutoCAD SHX Text DRAWING LIST: : SHEET 01 OF 04 NORTH & EAST ELEVATIONS, NOTES SHEET 02 OF 04 SOUTH & WEST ELEVATIONS, SECTIONS SHEET 03 OF 04 FOUNDATION PLAN SHEET 04 OF 04 ROOF PLAN - FASTENER SCHEDULE
AutoCAD SHX Text 04-25-25
AutoCAD SHX Text
AutoCAD SHX Text
REVISED PER TOWNSHIP COMMENTS,
AutoCAD SHX Text
CHANGED SHEET NUMBERS
AutoCAD SHX Text 09-08-26
AutoCAD SHX Text
AutoCAD SHX Text
ISSUED FOR BID
Br od he ad
R oa d, S ui te
Be th le he m , P
A
7-
.6
.5
F:
0.
1.
H an ov er En g.
co m
Be th le he m O ffi ce
AutoCAD SHX Text
CONTINUOUS RIDGE VENT
AutoCAD SHX Text
22 GAUGE STEEL ROOF
AutoCAD SHX Text
WEST ELEVATION (LOOKING EAST) SCALE "=1'-0"14"=1'-0"
AutoCAD SHX Text 80'-0"
AutoCAD SHX Text 7'-0"
AutoCAD SHX Text 6x6 P.T. KNEE BRACE
AutoCAD SHX Text 8x8 P.T. WOOD POST
AutoCAD SHX Text 2'-10"
AutoCAD SHX Text 2'-10"
AutoCAD SHX Text
INSTALL SNOW GUARDS STAGGERED, TYPICAL ON BOTH SIDES OF ROOF.
AutoCAD SHX Text
AutoCAD SHX Text INSTALL 24"x30" (MIN) ACCESS PANEL BETWEEN CEILING JOISTS
AutoCAD SHX Text
AutoCAD SHX Text 4'-0"
AutoCAD SHX Text
3/4 EXTERIOR GRADE PLYWOOD FOR BREAKER BOX, ONE CORNER ONLY, SEE PLAN VIEW
AutoCAD SHX Text
3/4 EXTERIOR PLYWOOD WITH STEEL SIDING, ONE CORNER ONLY, SEE PLAN VIEW
AutoCAD SHX Text
AutoCAD SHX Text
SEE CIVIL DWGS FOR CONCRETE WALKWAY INFO
AutoCAD SHX Text
SEE CIVIL DWGS FOR CONCRETE WALKWAY INFO
AutoCAD SHX Text 3 "58"
AutoCAD SHX Text
7 " (TYP)14" (TYP)
AutoCAD SHX Text 79'-4 "34"
AutoCAD SHX Text 3 "58"
AutoCAD SHX Text 9'-11 "332"
AutoCAD SHX Text 9'-11 "332"
AutoCAD SHX Text 9'-11 "332"
AutoCAD SHX Text 9'-11 "332"
AutoCAD SHX Text 9'-11 "332"
AutoCAD SHX Text 9'-11 "332"
AutoCAD SHX Text 9'-11 "332"
AutoCAD SHX Text 9'-11 "332"
AutoCAD SHX Text DRAWINGS WERE PREPARED IN ACCORDANCE WITH INTERNATIONAL CODE COUNCIL (ICC) "INTERNATIONAL BUILDING CODE 2018"
AutoCAD SHX Text
SOUTH ELEVATION (LOOKING NORTH) SCALE "=1'-0"14"=1'-0"
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 10'-0"
AutoCAD SHX Text 40'-0"
AutoCAD SHX Text
18'-2 " REFERENCE916" REFERENCE
AutoCAD SHX Text 2'-10"
AutoCAD SHX Text 2'-10"
AutoCAD SHX Text 7'-0"
AutoCAD SHX Text 4'-4"
AutoCAD SHX Text
STEEL SIDING
AutoCAD SHX Text
STEEL SIDING, TYPICAL BOTH GABLE ENDS
AutoCAD SHX Text
AutoCAD SHX Text 18"x24" RECTANGULAR PVC WEATHER FILTER GABLE LOUVER VENT, COLOR TO MATCH ROOF. TYPICAL BOTH GABLE ENDS
AutoCAD SHX Text 5'-0"
AutoCAD SHX Text
STEEL SIDING EXTERIOR, ONE CORNER ONLY
AutoCAD SHX Text
STEEL SIDING EXTERIOR, ONE CORNER ONLY
AutoCAD SHX Text
AutoCAD SHX Text
WALL PACK LIGHT
AutoCAD SHX Text 4'-0"
AutoCAD SHX Text
SEE CIVIL DWGS FOR CONCRETE WALKWAY INFO
AutoCAD SHX Text
SEE CIVIL DWGS FOR CONCRETE WALKWAY INFO
AutoCAD SHX Text
7 " (TYP)14" (TYP)
AutoCAD SHX Text 3 "58"
AutoCAD SHX Text 3 "58"
AutoCAD SHX Text 9'-10 "316"
AutoCAD SHX Text 9'-10 "316"
AutoCAD SHX Text 9'-10 "316"
AutoCAD SHX Text 9'-10 "316"
AutoCAD SHX Text 11'-0"
AutoCAD SHX Text 30"
AutoCAD SHX Text
1 " STANDING SEAM RAISED 12" STANDING SEAM RAISED PANEL ROOF, 22 GAUGE
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
PRE-ENGINEERED ROOF TRUSS, SEE TRUSS MANUFACTURERS DRAWINGS FOR SPACING
AutoCAD SHX Text 2x6 FASCIA COVERED IN ALUMINUM
AutoCAD SHX Text
ALUMINUM GUTTER
AutoCAD SHX Text 8x8 P.T. WOOD POST
AutoCAD SHX Text SIMPSON MOMENT POST BASE, MPB88Z FOR 8x8 WOOD POST
AutoCAD SHX Text
SONA TUBE WITH POURED CONCRETE, SEE SONA DETAIL
AutoCAD SHX Text 5 1/4"x11 7/8" PSL PLUS
AutoCAD SHX Text
TYPICAL WALL SECTION SCALE "=1'-0"12"=1'-0"
AutoCAD SHX Text
7 " (REF)14" (REF)
AutoCAD SHX Text 2'-10"
AutoCAD SHX Text 4'-0"
AutoCAD SHX Text 6"
AutoCAD SHX Text
12" EXPANSION JOINT
AutoCAD SHX Text
2" CLEAR
AutoCAD SHX Text 6"
AutoCAD SHX Text 6"
AutoCAD SHX Text 6" THICK POURED CONCRETE FLOOR WITH W2.9 x W2.9 WELDED WIRE REINFORCEMENT TOP AND BOTTOM
AutoCAD SHX Text
6" CRUSHED STONE
AutoCAD SHX Text
6" CRUSHED STONE
AutoCAD SHX Text
FOR SONA TUBE REINFORCEMENT SEE 30" SONA DETAIL ONSHEET 02
AutoCAD SHX Text 6x6 P.T. KNEE BRACE
AutoCAD SHX Text
5/8" CDX PLYWOOD SHEATHING WITH 30# FELT ROOF PAPER OVER
AutoCAD SHX Text
INSTALL SNOW GUARDS STAGGERED, TYPICAL ON BOTH SIDES OF ROOF
AutoCAD SHX Text
3/4" PLYWOOD CEILING WITH FLAT METAL ROOF MATERIAL ON BOTTOM SIDE OF PLYWOOD
AutoCAD SHX Text
3/4" PLYWOOD SOFFIT WITH FLAT METAL ROOF MATERIAL ON BOTTOM SIDE OF PLYWOOD
AutoCAD SHX Text 7'-0"
AutoCAD SHX Text
H10S SIMPSON HURRICANE TIE, (TYPICAL)
AutoCAD SHX Text
CC68 SIMPSON COLUMN CAP, (TYPICAL)
AutoCAD SHX Text B
AutoCAD SHX Text
AutoCAD SHX Text 2x4 NAILER
AutoCAD SHX Text
SEE CIVIL DWGS FOR CONCRETE WALKWAY INFO
AutoCAD SHX Text
BLOCKING BETWEEN TRUSSES BY TRUSS MANUFACTURER
AutoCAD SHX Text PROVIDE 2x6 NAILER AS REQ'D ON INSIDE FACE OF PAVILION FOR KBS1Z CONNECTOR TO POST
AutoCAD SHX Text 30"
AutoCAD SHX Text
SECTION SCALE "=1'-0"12"=1'-0"
AutoCAD SHX Text
6" CRUSHED STONE
AutoCAD SHX Text
6" CRUSHED STONE
AutoCAD SHX Text
FOR SONA TUBE REINFORCEMENT SEE 30" SONA DETAIL ONSHEET 02
AutoCAD SHX Text
CC68 SIMPSON COLUMN CAP, (TYPICAL)
AutoCAD SHX Text 6x6 P.T. KNEE BRACE (TYPICAL)
AutoCAD SHX Text
12" EXPANSION JOINT
AutoCAD SHX Text 6" THICK POURED CONCRETE FLOOR WITH W2.9 x W2.9 WELDED WIRE REINFORCEMENT TOP AND BOTTOM
AutoCAD SHX Text SIMPSON MOMENT POST BASE, MPB88Z FOR 8x8 WOOD POST
AutoCAD SHX Text 5 1/4"x11 7/8" PSL PLUS
AutoCAD SHX Text
3/4" PLYWOOD CEILING WITH FLAT METAL ROOF MATERIAL ON BOTTOM SIDE OF PLYWOOD
AutoCAD SHX Text
PRE-ENGINEERED ROOF TRUSS, SEE TRUSS MANUFACTURERS DRAWINGS FOR SPACING
AutoCAD SHX Text B
AutoCAD SHX Text
AutoCAD SHX Text
H10S SIMPSON HURRICANE TIE, (TYPICAL)
AutoCAD SHX Text SIMPSON KBS1Z CONNECTOR; BOTH SIDES OF EACH BRACE, BOTH ENDS OF EACH BRACE (TYPICAL)
AutoCAD SHX Text THIS DOCUMENT IS THE PROPERTY OF HANOVER ENGINEERING ASSOCIATES, INC. ANY USE OF A COPY OF THIS DOCUMENT THAT DOES NOT CONTAIN AN ORIGINAL SEAL AND SIGNATURE IS STRICTLY PROHIBITED. THIS DOCUMENT IS NOT PUBLISHED AND ALL RIGHTS ARE RESERVED BY HANOVER ENGINEERING ASSOCIATES, INC. THIS PLAN HAS BEEN SEALED WITH EITHER A RED INK SEAL OR A CRIMP SEAL. IF NEITHER APPEARS ON THIS PLAN, POSSIBLE REPRODUCTIONS OR ALTERATIONS MAY HAVE BEEN MADE WITHOUT THE APPROVAL OR KNOWLEDGE OF THE SIGNATORY.
AutoCAD SHX Text
DATE
AutoCAD SHX Text
NO.
AutoCAD SHX Text
REVISIONS
AutoCAD SHX Text
PLAN TITLE:
AutoCAD SHX Text
PROJECT TITLE:
AutoCAD SHX Text
SEAL:
AutoCAD SHX Text
OF
AutoCAD SHX Text
SHEET NO.
AutoCAD SHX Text
PROJECT NO.
AutoCAD SHX Text
DRAWN BY:
AutoCAD SHX Text
CHECKED BY:
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
EAF
AutoCAD SHX Text
TMT
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 04-25-25
AutoCAD SHX Text
AutoCAD SHX Text
REVISED PER TOWNSHIP COMMENTS,
AutoCAD SHX Text
AS NOTED
AutoCAD SHX Text 10-19-22
AutoCAD SHX Text
EA26-28
AutoCAD SHX Text
EAST ALLEN TOWNSHIP NORTHAMPTON COUNTY PENNSYLVANIA
AutoCAD SHX Text
SOUTH & WEST ELEVATIONS, SECTIONS
AutoCAD SHX Text
CHANGED SHEET NUMBERS
AutoCAD SHX Text 09-08-26
AutoCAD SHX Text
AutoCAD SHX Text
ISSUED FOR BID
BICENTENNIAL PARK PAVILION C STRUCTURAL PLANS
Br od he ad
R oa d, S ui te
Be th le he m , P
A
7-
.6
.5
F:
0.
1.
H an ov er En g.
co m
Be th le he m O ffi ce
AutoCAD SHX Text
FOUNDATION PLAN SCALE "=1'-0"14"=1'-0"
AutoCAD SHX Text 40'-0"
AutoCAD SHX Text 9'-11 "332"
AutoCAD SHX Text 9'-11 "332"
AutoCAD SHX Text 9'-11 "332"
AutoCAD SHX Text 9'-11 "332"
AutoCAD SHX Text 80'-0"
AutoCAD SHX Text 3 "58"
AutoCAD SHX Text 3 "58"
AutoCAD SHX Text 3 "58"
AutoCAD SHX Text 6" THICK POURED CONCRETE FLOOR WITH W2.9 x W2.9 WELDED WIRE REINFORCEMENT TOP AND BOTTOM
AutoCAD SHX Text 9'-11 "332"
AutoCAD SHX Text 9'-11 "332"
AutoCAD SHX Text 9'-11 "332"
AutoCAD SHX Text 9'-11 "332"
AutoCAD SHX Text 9'-10 "316"
AutoCAD SHX Text 9'-10 "316"
AutoCAD SHX Text 9'-10 "316"
AutoCAD SHX Text
(25) 30" SONA TUBES,STEEL REINFORCED FILLED WITH CONCRETE FOR 8x8 PT POST (SEE 30" SONA DETAILTHIS SHEET)
AutoCAD SHX Text
EXPANSION JOINT
AutoCAD SHX Text
CONTROL JOINT
AutoCAD SHX Text
CONTROL JOINT
AutoCAD SHX Text N
AutoCAD SHX Text
(REFERENCE)
AutoCAD SHX Text 5'-0"
AutoCAD SHX Text
3/4 EXTERIOR GRADE PLYWOOD (FLOOR TO BOTTOM OF ROOF TRUSS)
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 9'-10 "316"
AutoCAD SHX Text DRAWINGS WERE PREPARED IN ACCORDANCE WITH INTERNATIONAL CODE COUNCIL (ICC) "INTERNATIONAL BUILDING CODE 2018"
AutoCAD SHX Text 30" SONA DETAIL (FOR 8x8 POST) - (25) REQUIRED SCALE "=1'-0" 34"=1'-0"
AutoCAD SHX Text 2'-6"
AutoCAD SHX Text
4'-0" (MIN.)
AutoCAD SHX Text 6"
AutoCAD SHX Text C
AutoCAD SHX Text
CRUSHED STONE
AutoCAD SHX Text
FINISHED GRADE
AutoCAD SHX Text 3"
AutoCAD SHX Text 3"
AutoCAD SHX Text
#4 TIES @ 10" (TOP 3 BARS @ 3" SPACING)
AutoCAD SHX Text
(11) #7 VERTICAL BARS
AutoCAD SHX Text
3" CLEAR
AutoCAD SHX Text 7 "14"
AutoCAD SHX Text SIMPSON MOMENT POST BASE, MPB88Z FOR 8x8 WOOD POST
AutoCAD SHX Text 8 "14"
AutoCAD SHX Text C
AutoCAD SHX Text C
AutoCAD SHX Text
(THIS SHEET)
AutoCAD SHX Text 2 "38"
AutoCAD SHX Text
AutoCAD SHX Text
SECTION C-C SCALE "=1'-0" 34"=1'-0"
AutoCAD SHX Text
SEE 30" SONA TUBEDETAIL FOR REBAR SIZE AND SPACING
AutoCAD SHX Text 2'-6"
AutoCAD SHX Text 6"
AutoCAD SHX Text 1"
AutoCAD SHX Text 6"
AutoCAD SHX Text
6" AASHTO #57, COMPACTED
AutoCAD SHX Text
TYPICAL EXPANSION JOINT JOINT FORMED FULL DEPTH OF FLOOR SLAB SCALE 1 1/2"=1'-0"
AutoCAD SHX Text
FIBER EXPANSION JOINT
AutoCAD SHX Text
SIKA FLEX 20, NS, TG COLOR GRAY
AutoCAD SHX Text 5"
AutoCAD SHX Text 2"
AutoCAD SHX Text 2"
AutoCAD SHX Text 6"
AutoCAD SHX Text
CONTROL JOINT SCALE 1 1/2"=1'-0"
AutoCAD SHX Text
6" AASHTO #57, COMPACTED
AutoCAD SHX Text
SAW CUT 1 " DEEP12" DEEP
AutoCAD SHX Text 6"
AutoCAD SHX Text 1 "12"
AutoCAD SHX Text 2"
AutoCAD SHX Text 2"
AutoCAD SHX Text THIS DOCUMENT IS THE PROPERTY OF HANOVER ENGINEERING ASSOCIATES, INC. ANY USE OF A COPY OF THIS DOCUMENT THAT DOES NOT CONTAIN AN ORIGINAL SEAL AND SIGNATURE IS STRICTLY PROHIBITED. THIS DOCUMENT IS NOT PUBLISHED AND ALL RIGHTS ARE RESERVED BY HANOVER ENGINEERING ASSOCIATES, INC. THIS PLAN HAS BEEN SEALED WITH EITHER A RED INK SEAL OR A CRIMP SEAL. IF NEITHER APPEARS ON THIS PLAN, POSSIBLE REPRODUCTIONS OR ALTERATIONS MAY HAVE BEEN MADE WITHOUT THE APPROVAL OR KNOWLEDGE OF THE SIGNATORY.
AutoCAD SHX Text
DATE
AutoCAD SHX Text
NO.
AutoCAD SHX Text
REVISIONS
AutoCAD SHX Text
PLAN TITLE:
AutoCAD SHX Text
PROJECT TITLE:
AutoCAD SHX Text
SEAL:
AutoCAD SHX Text
OF
AutoCAD SHX Text
SHEET NO.
AutoCAD SHX Text
PROJECT NO.
AutoCAD SHX Text
DRAWN BY:
AutoCAD SHX Text
CHECKED BY:
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
EAF
AutoCAD SHX Text
TMT
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AS NOTED
AutoCAD SHX Text 10-19-22
AutoCAD SHX Text
EA26-28
AutoCAD SHX Text
EAST ALLEN TOWNSHIP NORTHAMPTON COUNTY PENNSYLVANIA
AutoCAD SHX Text
FOUNDATION PLAN & DETAILS
AutoCAD SHX Text CONCRETE NOTES: : 1. CONCRETE SPECIFICATIONS: A. CONCRETE MINIMUM COMPRESSIVE STRENGTH: 4000 PSI @ 28 DAYS, WITH CONCRETE MINIMUM COMPRESSIVE STRENGTH: 4000 PSI @ 28 DAYS, WITH WATER/CEMENT RATIO = 0.47 (MAX.) B. PRODUCTS CONTAINING CALCIUM CHLORIDE SHALL NOT BE USED PRODUCTS CONTAINING CALCIUM CHLORIDE SHALL NOT BE USED C. ALL REINFORCING STEEL TO BE NEW DOMESTIC DEFORMED BILLET STEEL ALL REINFORCING STEEL TO BE NEW DOMESTIC DEFORMED BILLET STEEL CONFORMING TO ASTM A-615 GRADE 60. D. ALL CONCRETE WORK TO BE IN ACCORDANCE WITH "THE BUILDING CODE ALL CONCRETE WORK TO BE IN ACCORDANCE WITH "THE BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE" ACI 318-14. E. ALL REINFORCEMENT DETAILS TO CONFORM TO "MANUAL OF STANDARD ALL REINFORCEMENT DETAILS TO CONFORM TO "MANUAL OF STANDARD PRACTICE FOR DETAILING REINFORCED CONCRETE STRUCTURES" ACI315-91 UNLESS OTHERWISE SPECIFIED. F. CONTRACTOR TO PROVIDE ALL SPACERS, CHAIRS, BOLSTERS, ETC. NECESSARY CONTRACTOR TO PROVIDE ALL SPACERS, CHAIRS, BOLSTERS, ETC. NECESSARY TO SUPPORT REINFORCING STEEL. CHAIRS WHICH BEAR ON EXPOSED CONCRETE SURFACES TO HAVE ENDS WHICH ARE PLASTIC TIPPED OR STAINLESS STEEL. 2: MATERIALS A. CEMENT USED IN CONCRETE MIX TO CONFORM TO THE REQUIREMENTS OF ASTM CEMENT USED IN CONCRETE MIX TO CONFORM TO THE REQUIREMENTS OF ASTM C-150 FOR TYPE I AND IIA PORTLAND CEMENT. B. FINE AGGREGATE TO BE NATURAL SAND CONFORMING TO ASTM C-33. FINE AGGREGATE TO BE NATURAL SAND CONFORMING TO ASTM C-33. C. COARSE AGGREGATE TO CONFORM TO ASTM C-33 SIZE NO. 57. MATERIAL TO COARSE AGGREGATE TO CONFORM TO ASTM C-33 SIZE NO. 57. MATERIAL TO BE CRUSHED LIMESTONE OR QUARTZ WITH AN ABSORPTION NO GREATER THAN 0.3%. D. ALL CONCRETE TO HAVE A SLUMP NO LESS THAN 2" OR GREATER THAN 4". ALL CONCRETE TO HAVE A SLUMP NO LESS THAN 2" OR GREATER THAN 4". E. ALL CONCRETE TO BE AIR ENTRAINED WITH AN AIR CONTENT BY VOLUME OF ALL CONCRETE TO BE AIR ENTRAINED WITH AN AIR CONTENT BY VOLUME OF AT LEAST 3% AND NOT MORE THAN 6%. 3. EXECUTION: A. FORMS TO CONFORM TO THE SHAPE, LINES, GRADES AND DIMENSIONS OF THE FORMS TO CONFORM TO THE SHAPE, LINES, GRADES AND DIMENSIONS OF THE CONCRETE AS CALLED FOR ON THE DRAWINGS. LUMBER USED IN FORMS FOR EXPOSED SURFACES TO BE DRESSED TO A UNIFORM THICKNESS AND BE FREE FROM LOOSE KNOTS OR OTHER DEFECTS. FORMS TO BE SUFFICIENTLY TIGHT TO PREVENT LEAKAGE OF MORTAR. THEY NEED TO BE PROPERLY BRACED TOGETHER SO AS TO MAINTAIN THE DESIRED POSITION AND SHAPE DURING AND AFTER PLACING CONCRETE FOR QUICK AND EASY RELEASE. B. THE INSIDE FORMS TO BE COATED WITH NON-STAINING WATER REPELLENT THE INSIDE FORMS TO BE COATED WITH NON-STAINING WATER REPELLENT MATERIAL TO PREVENT ADHESION OF CONCRETE TO THE FORMS AND PROVIDE FOR QUICK RELEASE. C. FORMS ARE NOT TO BE REMOVED FROM VERTICAL SURFACES EARLIER THAN 24 FORMS ARE NOT TO BE REMOVED FROM VERTICAL SURFACES EARLIER THAN 24 HOURS AFTER CONCRETE IS POURED. 4. REINFORCEMENT: A. BEFORE BEING POSITIONED, REINFORCING BARS TO BE FREE FROM LOOSE MILL BEFORE BEING POSITIONED, REINFORCING BARS TO BE FREE FROM LOOSE MILL AND RUST SCALE FROM COATINGS: INCLUDING ICE, THAT DESTROYS OR REDUCES THE BOND. WHERE THERE IS DELAY IN DEPOSTING CONCRETE, REINFORCEMENT SHALL BE REINSPECTED AND CLEANED WHEN NECESSARY. B. REINFORCING BARS ARE NOT TO BE SPLICED BY WELDING. SPLICES ARE TO BE REINFORCING BARS ARE NOT TO BE SPLICED BY WELDING. SPLICES ARE TO BE LAPPED IN ACCORDANCE WITH ACI 318-11 SECTION 12.14 C. REINFORCING BARS TO BE ACCURATELY POSITIONED AND SECURED AGAINST REINFORCING BARS TO BE ACCURATELY POSITIONED AND SECURED AGAINST DISPLACEMENT BY USING ANNEALED IRON WIRE TIES OR SUITABLE CLIPS AT INTERSECTIONS AND BE SUPPORTED BY CONCRETE OR METAL SUPPORTS, SPACERS OR METAL HANGERS. THE USE OF METAL SUPPORTS TO BE IN ACCORDANCE WITH THE AMERICAN CONCRETE INSTITUTE STANDARD. 5. PLACING OF CONCRETE A. WATER TO BE REMOVED FROM THE SPACE TO BE OCCUPIED BY CONCRETE WATER TO BE REMOVED FROM THE SPACE TO BE OCCUPIED BY CONCRETE BEFORE CONCRETE IS DEPOSITED, UNLESS OTHERWISE DIRECTED BY OWNER. B. CONCRETE TO BE DEPOSITED IN A MANNER THAT WILL AVOID INCLUSION OF CONCRETE TO BE DEPOSITED IN A MANNER THAT WILL AVOID INCLUSION OF AIR POCKETS. C. ALL CONCRETE PLACED UNDER THESE SPECIFICATION TO BE SO PROTECTED ALL CONCRETE PLACED UNDER THESE SPECIFICATION TO BE SO PROTECTED THAT THE TEMPERATURE AT THE SURFACE WILL NOT FALL BELOW 50°F.BEFORE PLACING CONCRETE, FORMS AND/OR SUBGRADE TO BE FREE FROM FROST AND ICE, AND AFTER THE CONCRETE IS PLACED IT SHALL BE PROTECTED ON ALL EXPOSED SIDES BY STRAW, TARPAULINS OR OTHER APPROVED MEANS. THE METHODS OF HEATING THE MATERIAL AND METHODS OF HEATING THE MATERIAL AND PROTECTING THE CONCRETE TO BE APPROVED BY THE OWNER. SLATS, CHEMICALS AND OTHER FOREIGN MATERIALS WILL NOT BE MIXED WITH THE CONCRETE FOR THE PURPOSE OF PREVENTING FREEZING. TEMPERATURE OF CONCRETE NOT TO EXCEED 90°F.D. SHOULD POOR SOILS, SUCH AS LOOSE SAND OR VERY SOFT CLAY BE SHOULD POOR SOILS, SUCH AS LOOSE SAND OR VERY SOFT CLAY BE ENCOUNTERED DURING EXCAVATION, FOOTING DEPTHS TO BE INCREASED TO GOOD BEARING DISTANCE OR 12", WHICHEVER IS GREATER 6. FINISHES AND RESURFACING: A. THE CONTRACTOR TO EXERCISE THE NECESSARY CARE AND PROVIDE THE CONTRACTOR TO EXERCISE THE NECESSARY CARE AND PROVIDE EXPERIENCED CRAFTSMEN TO CONSTRUCT THE CONCRETE STRUCTURES TO THE DIMENSIONS AS SHOWN ON THE DRAWINGS. HORIZONTAL SURFACES TO BE HORIZONTAL SURFACES TO BE ACCURATE WITHIN " OF THE THEORETICAL ELEVATIONS. SURFACES MUST BE 14" OF THE THEORETICAL ELEVATIONS. SURFACES MUST BE SMOOTH AND NOT VARY MORE THAN " AS MEASURED UNDER A 10 FOOT 14" AS MEASURED UNDER A 10 FOOT STRAIGHTEDGE. B. EXPOSED CONCRETE SURFACES TO BE TRUE AND EVEN, FREE FROM ROUGH EXPOSED CONCRETE SURFACES TO BE TRUE AND EVEN, FREE FROM ROUGH AREAS, DEPRESSIONS OR PROJECTIONS. C. ALL TOP SURFACES OF CONCRETE STRUCTURES MUST FIRST BE LEVELED BY ALL TOP SURFACES OF CONCRETE STRUCTURES MUST FIRST BE LEVELED BY STRIKING OFF THE FRESHLY PLACED CONCRETE TO THE ELEVATION DESIRED. THE FINISH TO BE WOOD FLOATED AND FINISHED WITH A FLEXIBLE BRISTLE BROOM. 7. CURING: CONCRETE TO BE CURED AND PROTECTED FROM FREEZING ACCORDING TO THE RECOMMENDATIONS OF THE ACI COMMITTEE 306 REPORT, COLD WEATHER CONCRETING. 8. USE OF STRUCTURES: STRUCTURES MAY NOT BE USED UNTIL CONCRETE DESIGN STRENGTH HAS BEEN REACHED (APPROXIMATELY 7 DAYS OR LESS), KEEP CONCRETE WET UNTIL THEN. 9. FOUNDATIONS: FOUNDATIONS ARE DESIGNED ASSUMING 2,500 PSF BEARING CAPACITY. BEARING CAPACITY MUST BE CONFIRMED BY A REGISTERED PROFESSIONAL GEOTECHNICAL ENGINEER PRIOR TO CONSTRUCTION.
AutoCAD SHX Text 03-12-24
AutoCAD SHX Text
AutoCAD SHX Text
ADDED 6X6 POST AND 3/4 PLYWOOD
AutoCAD SHX Text 04-25-25
AutoCAD SHX Text
AutoCAD SHX Text
REVISED PER TOWNSHIP COMMENTS,
AutoCAD SHX Text
CHANGED SHEET NUMBERS
AutoCAD SHX Text 09-08-26
AutoCAD SHX Text
AutoCAD SHX Text
ISSUED FOR BID
Br od he ad
R oa d, S ui te
Be th le he m , P
A
7-
.6
.5
F:
0.
1.
H an ov er En g.
co m
Be th le he m O ffi ce
AutoCAD SHX Text
ROOF PLAN SCALE "=1'-0"14"=1'-0"
AutoCAD SHX Text 40'-0"
AutoCAD SHX Text 3 "58"
AutoCAD SHX Text 80'-0"
AutoCAD SHX Text 3 "58"
AutoCAD SHX Text 3 "58"
AutoCAD SHX Text 3 "58"
AutoCAD SHX Text 9'-10 "316"
AutoCAD SHX Text 9'-10 "316"
AutoCAD SHX Text
4/12 ROOF SLOPE
AutoCAD SHX Text
CONTINUOUS RIDGE VENT
AutoCAD SHX Text
4/12 ROOF SLOPE
AutoCAD SHX Text 2'-10"
AutoCAD SHX Text 2'-10"
AutoCAD SHX Text 45'-8"
AutoCAD SHX Text 2'-10"
AutoCAD SHX Text 2'-10"
AutoCAD SHX Text 85'-8"
AutoCAD SHX Text PRE-ENGINEERED ROOF TRUSS SYSTEM DESIGN DRAWINGS TO BE SUPPLIED BY TRUSS MANUFACTURER AND CARRY A PROFESSIONAL ENGINEER'S SEAL IN THE STATE OF PENNSYLVANIA.
AutoCAD SHX Text 2x6 FASCIA
AutoCAD SHX Text PRE-ENGINEERED ROOF TRUSS SYSTEM DESIGN DRAWINGS TO BE SUPPLIED BY TRUSS MANUFACTURER AND CARRY A PROFESSIONAL ENGINEER'S SEAL IN THE STATE OF PENNSYLVANIA.
AutoCAD SHX Text 5 1/4"x11 7/8" PSL PLUS
AutoCAD SHX Text 8x8 P.T. WOOD POST (TYP)
AutoCAD SHX Text 2x6 FASCIA
AutoCAD SHX Text
(3) 2x12 HEADER
AutoCAD SHX Text
(3) 2x12 HEADER
AutoCAD SHX Text
(3) 2x12 HEADER
AutoCAD SHX Text
(3) 2x12 HEADER
AutoCAD SHX Text
(3) 2x12 HEADER
AutoCAD SHX Text
(3) 2x12 HEADER
AutoCAD SHX Text
AutoCAD SHX Text N
AutoCAD SHX Text
(REFERENCE)
AutoCAD SHX Text A
AutoCAD SHX Text
AutoCAD SHX Text 24"x30" (MIN) CEILING ACCESS PANEL BELOW, TYPICAL (2) PLACES (BETWEEN ROOF TRUSS)
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 5'-0"
AutoCAD SHX Text
3/4 EXTERIOR GRADE PLYWOOD (FLOOR TO BOTTOM OF ROOF TRUSS)
AutoCAD SHX Text
AutoCAD SHX Text 5 1/4"x11 7/8" PSL PLUS
AutoCAD SHX Text 5 1/4"x11 7/8" PSL PLUS
AutoCAD SHX Text 5 1/4"x11 7/8" PSL PLUS
AutoCAD SHX Text 5 1/4"x11 7/8" PSL PLUS
AutoCAD SHX Text 5 1/4"x11 7/8" PSL PLUS
AutoCAD SHX Text 5 1/4"x11 7/8" PSL PLUS
AutoCAD SHX Text 5 1/4"x11 7/8" PSL PLUS
AutoCAD SHX Text 5 1/4"x11 7/8" PSL PLUS
AutoCAD SHX Text 5 1/4"x11 7/8" PSL PLUS
AutoCAD SHX Text 5 1/4"x11 7/8" PSL PLUS
AutoCAD SHX Text 5 1/4"x11 7/8" PSL PLUS
AutoCAD SHX Text 5 1/4"x11 7/8" PSL PLUS
AutoCAD SHX Text 5 1/4"x11 7/8" PSL PLUS
AutoCAD SHX Text 5 1/4"x11 7/8" PSL PLUS
AutoCAD SHX Text 5 1/4"x11 7/8" PSL PLUS
AutoCAD SHX Text 9'-11 "332"
AutoCAD SHX Text 9'-11 "332"
AutoCAD SHX Text 9'-11 "332"
AutoCAD SHX Text 9'-11 "332"
AutoCAD SHX Text 9'-11 "332"
AutoCAD SHX Text 9'-11 "332"
AutoCAD SHX Text 9'-11 "332"
AutoCAD SHX Text 9'-11 "332"
AutoCAD SHX Text 9'-10 "316"
AutoCAD SHX Text 9'-10 "316"
AutoCAD SHX Text
(3) 2x12 HEADER
AutoCAD SHX Text
(3) 2x12 HEADER
AutoCAD SHX Text DRAWINGS WERE PREPARED IN ACCORDANCE WITH INTERNATIONAL CODE COUNCIL (ICC) "INTERNATIONAL BUILDING CODE 2018"
AutoCAD SHX Text
NUMBER AND TYPE OF FASTENER
AutoCAD SHX Text
DESCRIPTION OF BUILDING ELEMENTS
AutoCAD SHX Text
SPACING OF FASTENERS
AutoCAD SHX Text 3-8d (2 1/2" x 0.113")
AutoCAD SHX Text
BLOCKING BETWEEN JOISTS OR TRUSS TO TOP PLATE, TOE NAIL
AutoCAD SHX Text
AutoCAD SHX Text 3-8d (2 1/2" x 0.113")
AutoCAD SHX Text
CEILING JOISTS TO PLATE, TOE NAIL
AutoCAD SHX Text
AutoCAD SHX Text 4-10d
AutoCAD SHX Text
CEILING JOISTS NOT ATTACHED TO PARALLEL RAFTER, LAPS OVER PARTITIONS, FACE NAIL
AutoCAD SHX Text
AutoCAD SHX Text 4-10d (3" x 0.148")
AutoCAD SHX Text COLLAR TIE RAFTER, FACE NAIL OR 1 " x 20 GAUGE 14" x 20 GAUGE RIDGE STRAP
AutoCAD SHX Text
AutoCAD SHX Text 3-16d (3 1/2" x 0.135")
AutoCAD SHX Text
RAFTER TO PLATE, TOE NAIL
AutoCAD SHX Text
AutoCAD SHX Text 4-16d (3 1/2" x 0.135") 3-16d (3 " x 0.135")12" x 0.135")
AutoCAD SHX Text
ROOF TRUSS TO RIDGE, VALLEY OR HIP TRUSS: TOE NAIL FACE NAIL
AutoCAD SHX Text
AutoCAD SHX Text
ROOF
AutoCAD SHX Text
WALL
AutoCAD SHX Text 16d (3 1/2" x 0.162")
AutoCAD SHX Text
16" O.C. ALONG EACH EDGE
AutoCAD SHX Text
CONTINUED HEADER
AutoCAD SHX Text
BUILT-UP HEADER, TWO PIECES WITH " SPACER12" SPACER
AutoCAD SHX Text 4-10d (3" x 0.128")
AutoCAD SHX Text
AutoCAD SHX Text 4-8d (2 1/2" x 0.131")
AutoCAD SHX Text
CONTINUOUS HEADER TO STUD, TOE NAIL
AutoCAD SHX Text
AutoCAD SHX Text
FASTENER SCHEDULE FOR STRUCTURAL MEMBERS
AutoCAD SHX Text
DESCRIPTION OF FASTENER
AutoCAD SHX Text
DESCRIPTION OF BUILDING MATERIALS
AutoCAD SHX Text
SPACING OF FASTENERS
AutoCAD SHX Text
EDGES (INCHES)
AutoCAD SHX Text
INTERMEDIATE SUPPORTS (INCHES)
AutoCAD SHX Text WOOD STRUCTURAL PANELS, SUBFLOOR, ROOF AND INTERIOR WALL SHEATHING TO FRAMING AND PARTICALEBOARD WALL SHEATHING TO FRAME
AutoCAD SHX Text 3/8" - 1/2"
AutoCAD SHX Text 6d COMMON (2" x 0.113") NAIL (SUBFLOOR, WALL) 8d COMMON (2 1/2" x 0.131") NAIL (ROOF)
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 5/16" - 1/2"
AutoCAD SHX Text 6d COMMON (2" x 0.113") NAIL (SUBFLOOR, WALL) 8d COMMON (2 1/2" x 0.131") NAIL (ROOF)
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 19/32" - 1"
AutoCAD SHX Text 8d COMMON NAIL (2 1/2" x 0.131")
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
OTHER WALL SHEATHING
AutoCAD SHX Text
1/2" STRUCTURAL CELLULOSIC FIBERBOARD SHEATHING
AutoCAD SHX Text 1 1/2" GALVANIZED ROOFING NAIL, 7/16" HEAD DIA. OR 1" CROWN STAPLE 16 GA. 1 1/4" LONG
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
25/32" STRUCTURAL CELLULOSIC FIBERBOARD SHEATHING
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 1 3/4" GALVANIZED ROOFING NAIL, 7/16" HEAD DIA. OR 1" CROWN STAPLE 16 GA. 1 1/4" LONG
AutoCAD SHX Text
1. ALL NAILS ARE SMOOTH-COMMON, BOX OR REFORMED SHANKS EXCEPT WHERE OTHERWISE STATED. NAILS ALL NAILS ARE SMOOTH-COMMON, BOX OR REFORMED SHANKS EXCEPT WHERE OTHERWISE STATED. NAILS USED FOR FRAMING AND SHEATHING CONNECTIONS SHALL HAVE MINIMUM AVERAGE BENDING YIELD STRENGTHS AS SHOWN: 80 ksi FOR SHANK DIAMETER OF 0.192 INCH (20D COMMON NAIL), 90 ksi FOR SHANK DIAMETERS LARGER THAN 0.142 INCH BUT NOT LARGER THAN 0.177 INCH, AND 100 ksi FOR SHANK DIAMETERS OF 0.142 INCH OR LESS. 2. STAPLES ARE 16 GAGE WIRE AND HAVE A MINIMUM 7/16 INCH ON DIAMETER CROWN WIDTH. STAPLES ARE 16 GAGE WIRE AND HAVE A MINIMUM 7/16 INCH ON DIAMETER CROWN WIDTH. 3. NAILS SHALL BE SPACED AT NOT MORE THAN 6 INCHES ON CENTER AT ALL SUPPORTS WHERE SPANS ARE NAILS SHALL BE SPACED AT NOT MORE THAN 6 INCHES ON CENTER AT ALL SUPPORTS WHERE SPANS ARE 48" OR GREATER. 4. SPACING OF FASTENERS ON ROOF SHEATHING PANEL EDGES TO PANEL EDGES SUPPORTED BY FRAMING SPACING OF FASTENERS ON ROOF SHEATHING PANEL EDGES TO PANEL EDGES SUPPORTED BY FRAMING MEMBERS AND REQUIRED BLOCKING.
AutoCAD SHX Text
SEE SHEET 01 FOR GENERAL NOTES, LOADS, ROOF TRUSS AND SHEATHING NOTES.
AutoCAD SHX Text
MATERIAL STRENGTH
AutoCAD SHX Text
WOOD FRAMING MEMBER
AutoCAD SHX Text
SOUTHERN PINE, #1 GRADE
AutoCAD SHX Text
SOLID WOOD POSTS
AutoCAD SHX Text
STRUCTURAL WOOD MEMBER SCHEDULE
AutoCAD SHX Text
SOUTHERN PINE, #1 GRADE
AutoCAD SHX Text
DIAGONAL BRACES
AutoCAD SHX Text WEYERHAEUSER PARALLAM E =1,650,000 PSI, Fb = 2,275 PSI, Fv = 215 PSI
AutoCAD SHX Text
PARALLEL STRAND PRESERVATIVE TREATED LUMBER (PSL PLUS)
AutoCAD SHX Text
SOUTHERN PINE, #1 GRADE
AutoCAD SHX Text 2x12 BEAMS
AutoCAD SHX Text
1. ALL WOOD FRAMING MEMBERS MUST BE PRESERVATIVE TREATED.ALL WOOD FRAMING MEMBERS MUST BE PRESERVATIVE TREATED.
AutoCAD SHX Text THIS DOCUMENT IS THE PROPERTY OF HANOVER ENGINEERING ASSOCIATES, INC. ANY USE OF A COPY OF THIS DOCUMENT THAT DOES NOT CONTAIN AN ORIGINAL SEAL AND SIGNATURE IS STRICTLY PROHIBITED. THIS DOCUMENT IS NOT PUBLISHED AND ALL RIGHTS ARE RESERVED BY HANOVER ENGINEERING ASSOCIATES, INC. THIS PLAN HAS BEEN SEALED WITH EITHER A RED INK SEAL OR A CRIMP SEAL. IF NEITHER APPEARS ON THIS PLAN, POSSIBLE REPRODUCTIONS OR ALTERATIONS MAY HAVE BEEN MADE WITHOUT THE APPROVAL OR KNOWLEDGE OF THE SIGNATORY.
AutoCAD SHX Text
DATE
AutoCAD SHX Text
NO.
AutoCAD SHX Text
REVISIONS
AutoCAD SHX Text
PLAN TITLE:
AutoCAD SHX Text
PROJECT TITLE:
AutoCAD SHX Text
SEAL:
AutoCAD SHX Text
OF
AutoCAD SHX Text
SHEET NO.
AutoCAD SHX Text
PROJECT NO.
AutoCAD SHX Text
DRAWN BY:
AutoCAD SHX Text
CHECKED BY:
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
EAF
AutoCAD SHX Text
TMT
AutoCAD SHX Text 10-19-22
AutoCAD SHX Text
EA26-28
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
EAST ALLEN TOWNSHIP NORTHAMPTON COUNTY PENNSYLVANIA
AutoCAD SHX Text
AS NOTED
AutoCAD SHX Text
ROOF PLAN & WOOD SCHEDULES
AutoCAD SHX Text 03-12-24
AutoCAD SHX Text
AutoCAD SHX Text
ADDED 6X6 POST AND 3/4 PLYWOOD
AutoCAD SHX Text 04-25-25
AutoCAD SHX Text
AutoCAD SHX Text
REVISED PER TOWNSHIP COMMENTS,
AutoCAD SHX Text
CHANGED SHEET NUMBERS
AutoCAD SHX Text 09-08-26
AutoCAD SHX Text
AutoCAD SHX Text
ISSUED FOR BID
File details come from the government source that posted it. Updated .