4-04 - Attachment C (Style 2 - 3 rail flush bottom).pdf

PDF 1 MB Posted

Attached to
ITB 2026-004 Golf Course Fence Replacement
Solicitation number
ITB 2026-004
Issued by
Johnson County, Texas

About this file

This is a technical specification drawing for a 3-rail flush bottom fence panel system (Model C2-Titan-3R-FB) produced by SPS Centurion 2, submitted by Robert Curry in support of the Texas golf course fence replacement project (ITB 2026-004). The drawing details the construction specifications for wrought iron fence panels designed to accommodate the approximately 5,280 linear feet of 6-foot-tall fencing required for the project. The specification includes comprehensive post setting charts indicating panel widths of 6 feet and 8 feet with corresponding post heights ranging from 3 feet to 8 feet tall, post sizes varying from 2 inches to 6 inches, and internal locking rods through each rail and picket for structural integrity. The fence system features 1-1/2-inch by 14-gauge rails, 3/4-inch by 16-gauge pickets spaced at 1/2-inch on center, and multiple mounting bracket options including Boulevard line brackets, corner brackets, end brackets, and commercial swivel brackets for flexible installation configurations.

The specification provides detailed selections for post materials, including plated post options in gauges ranging from 16 to 3/16 inches depending on post size, and multiple ornament options for aesthetic customization. Mounting options include concrete anchor bolts with three flat mount commercial brackets and various depth selections. The drawing indicates that 6-foot panels will contain 15 pickets with post spacing as shown in the accompanying post setting chart, with all posts mounted to the center of the plate unless offset installation is required. Plated posts are noted as optional, and internal locking rods are provided through each rail and picket for enhanced structural performance and security.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Drawing NO.Revision NO.

Effective Date

Robert Curry Drawn By:

Approved By/Date

Project:

8'

3" POSTS

96"

POST

SETTINGS

± 1/2" O.C.

2-1/2" POSTS

76-3/4"

POST SIZE

PANEL WIDTH 6'8'6'

95-1/2" 77-1/4"

2" POSTS

95"76-1/4"

6'8'6'

4" POSTS

97"78-1/4"

8'

80-1/4"

6" POSTS

6' 8'

99"

Post Setting Chart

Concrete Anchor Bolt

Flat Mount Commercial Bracket

Boulevard Line Bracket

Boulevard Corner Bracket

Boulevard End Bracket

Commercial Swivel Bracket

Mounting Bracket Options

Boulevard Brackets only work with

2” and 2-1/2” Post

C2-Titan-3R-FB

SPS Centurion 2 Panel :

Titan 3-Rail

3-15/16”

TYP1-1/8”

5-1/2”

2”

1-1/2” x 14 Ga. Rail

1-1/2” x 14 Ga. Rail

1-1/2” x 14 Ga. Rail

3/4” x16 Ga.

Picket

6-5/8”

1-1/2” x 1-1/2” x 14 Ga. Rail

See Post Setting Chart ± 1/2" O.C.

4x4 6x6 8x8 12x12

Size Thickness

Plate Selection for Plated Post Post

Distance -/+

-NTS

Notes 6' Panels will be identical to this drawing, except there will be 15 pickets and post spacing shown in post setting chart.

Rings are optional.

Plated post optional. All post will be mounted to center of plate unless o�set is needed for installation

2 Ornament Options

Depth Selection

Plated Post

36”

3’ Tall 3.5’ Tall 4’ Tall 5’ Tall 6’ Tall 7’ Tall 8’ Tall

Height Selection Box

3’ Tall = 32-1/2” 3.5’ Tall = 38-1/2” 4’ Tall = 44-1/2” 5’ Tall = 56-1/2” 6’ Tall = 68-1/2” 7’ Tall = 80-1/2” 8’ Tall = 92-1/2”

Internal locking rods through each rail & picket

2-1/2” x 16 Ga. Post 2” x 14 Ga. Post

2-1/2” x 14 Ga. Post 2-1/2” x 12 Ga. Post

3” x 12 Ga. Post 4” x 11 Ga. Post

6” x 3/16” Wall. Post

2” x 16 Ga. Post Post Selection Box

File details come from the government source that posted it. Updated .