This is a unit price sheet for the MCC 3rd Avenue Ventilation Project (Event 4386), which outlines the equipment and services required for a ventilation system upgrade. The project encompasses four primary components: replacement and installation of two exhaust fans (EF-1 and EF-2) and two supply fans (SF-1 and SF-2) with specifications ranging from 24,000 to 26,250 CFM at 0.25" water column with 3.0 to 5.0 HP motors operating at 480V/3PH; installation of a CO/NO2 monitoring system including sensors, control panels, wiring, programming, testing, and protective cages; additional work including backdraft dampers, manual override switches, and ductwork modifications; and an optional Variable Frequency Drive (VFD) alternate for all four fans with programming and integration services. Bidders must provide pricing for all line items to be considered responsive, with the award based on the lowest lump sum bid rather than individual unit prices.
The pricing structure requires bidders to complete five bid categories: Ventilation Fans, CO/NO2 Monitoring System, Additional Work, and Alternate No. 1 for VFDs, with subtotals for each category leading to a base bid total to be entered in eSupplier. For the CO/NO2 monitoring system, bidders must select from five system options: ACME, MACURCO, TOXALERT, HONEYWELL, or CET OPERA. No set-asides, contract term, renewal options, funding sources, or award dates are specified in this unit price sheet.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Responsible_Contractor_A1_A2_combined.pdf | ||
| Call_for_Bids.pdf | ||
| Event_4386_Specifications.pdf | ||
| BID_-_MCC_-_3rd_Avenue_Ventilation_Project.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Ventilation Fans
| UNIT PRICE SHEET | |
| MCC - 3rd Avenue Ventilation Project | |
| EVENT: 4386 | |
| COMPANY NAME: | |
| Bidders must provide a price for ALL lines in order to be considered responsive. | |
| Please note: we are asking for Unit Prices but the bid will be awarded based on the lowest Lump Sum Bid. | |
| 1 | Ventilation Fan Unit Pricing |
| Description | QTY | Unit Price | Extended Price | ||
| 1 | EF-1: 24,000 CFM, 0.25" WC, Direct Drive, 3.0 HP, 480V/3: Replace & Install Exhaust Fan Level 1 | 1 | $ - 0 | ||
| 2 | SF-1: 24,000 CFM, 0.25" WC, Direct Drive, 3.0 HP, 480V/3PH: Replace & Install Supply Fan Level 1 | 1 | $ - 0 | ||
| 3 | |||||
| EF-2: 26,250 CFM, 0.25" WC, Direct Drive, 5.0 HP, 480V/3PH: Replace & Install Exhaust Fan Level 2 | 1 | $ - 0 | |||
| 4 | SF-2: 26,250 CFM, 0.25" WC, Direct Drive, 5.0 HP, 480V/3PH: Replace & Install Supply Fan Level 2 | 1 | $ - 0 | ||
| Total | $ - 0 | ||||
| 2 | CO/NO2 Monitoring System Unit Pricing | ||||
| Description | QTY | Unit Price | Extended Price | ||
| 1 | CO/NO2 Sensors: Install per drawings and coverage requirements | 1 | $ - 0 | ||
| 2 | Control Panel(s): Provide and install | 1 | $ - 0 | ||
| 3 | System integration: Wiring, programming, testing (Lot) | 1 | $ - 0 | ||
| 4 | CO/NO₂ Sensor Protective Cages, Furnish & Install | 1 | $ - 0 | ||
| 5 | System Selection (Choose from Selection Below) | ||||
| 6 | Select | ||||
| Total | $ - 0 | ||||
| 3 | Additional Work | ||||
| Description | QTY | Unit Price | Extended Price | ||
| 1 | Backdraft dampers: As required | 2 | $ - 0 | ||
| 2 | Manual override switches: As shown on drawings | 2 | $ - 0 | ||
| 3 | Misc. ductwork modifications: Per field conditions | 1 | $ - 0 | ||
| Total | $ - 0 |
4 Alternate No. 1 - Variable Frequency Drives (VFDs)
| Description | QTY | Unit Price | Extended Price | |
| VFD for EF-1 | 1 | $ - 0 | ||
| VFD for SF-1 | 1 | $ - 0 | ||
| VFD for EF-2 | 1 | $ - 0 | ||
| VFD for SF-2 | 1 | $ - 0 | ||
| Programming, Integration & Startup Lump Sum | 1 | $ - 0 | ||
| Total | $ - 0 | |||
| 5 | Bid Summary | |||
| Category | Subtotal ($) | |||
| 1 | Ventilatiopn Fans | $ - 0 | ||
| 2 | CO/NO2 Monitoring System | $ - 0 | ||
| 3 | Additional Work | $ - 0 | ||
| 5 | Base Bid Total (Enter This Amount in eSupplier) | $ - 0 |