36E77619R0080-0004003.pdf
PDF 105 KB Posted
- Attached to
- 36E77619R0080 - Fayetteville D-Wing Renovation
- Solicitation number
- 36E77619R0080
About this file
36E77619R0080 0004 08 71 00 Door Hardware.pdf
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36E77619R0080-0007000.docx | DOCX document | |
| 36E77619R0080-0006000.docx | DOCX document | |
| 36E77619R0080-0005001.pdf | ||
| 36E77619R0080-0005000.docx | DOCX document | |
| 36E77619R0080-0004004.pdf | ||
| 36E77619R0080-0004001.pdf | ||
| 36E77619R0080-0004000.docx | DOCX document | |
| 36E77619R0080-0004002.pdf | ||
| 36E77619R0080-0003000.docx | DOCX document | |
| 36E77619R0080-0002000.docx | DOCX document | |
| 36E77619R0080-0001000.docx | DOCX document | |
| 36E77619R0080-012.pdf | ||
| 36E77619R0080-008.pdf | ||
| 36E77619R0080-006.pdf | ||
| 36E77619R0080-005.pdf | ||
| 36E77619R0080-011.docx | DOCX document | |
| 36E77619R0080-009.pdf | ||
| 36E77619R0080-001.docx | DOCX document | |
| 36E77619R0080-002.doc | DOC document | |
| 36E77619R0080-004.pdf | ||
| 36E77619R0080-010.docx | DOCX document | |
| 36E77619R0080-003.pdf | ||
| 36E77619R0080-007.pdf | ||
| 36E77619R0080-000.docx | DOCX document |
Show all 24
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
FAYETTEVILLE VA MEDICAL CENTER RENOVATE D WING DENTAL
CD Submission January 2019
DOOR HARDWARE 08 71 00-1
SECTION 08 71 00
DOOR HARDWARE
PART 1 - GENERAL
1.1 DESCRIPTION
A. Door hardware and related items necessary for co mplete installation and operation of doors.
1.2 RELATED WORK
A. Caulking: Section 07 92 00 JOINT SEALANTS.
B. Application of Hardware: Section 08 14 00, WOOD DOORS; Section 08 11
13, HOLLOW METAL DOORS AND FRAMES;
C. Painting: Section 09 91 00, PAINTING.
D. Electrical: Division 26, ELECTRICAL.
E. Fire Detection: Section 28 31 00, FIRE DETECTION AND ALARM.
1.3 GENERAL
A. All hardware shall comply with UFAS, (Uniform Fe deral Accessible
Standards) unless specified otherwise.
B. Provide rated door hardware assemblies where req uired by most current version of the International Building Code (IBC).
C. Hardware for Labeled Fire Doors and Exit Doors: Conform to requirements of NFPA 80 for labeled fire doors and to NFPA 101 f or exit doors, as well as to other requirements specified. Provide ha rdware listed by UL, except where heavier materials, large size, or bett er grades are specified herein under paragraph HARDWARE SETS. In lieu of UL labeling and listing, test reports from a nationally recogni zed testing agency may be submitted showing that hardware has been tes ted in accordance with UL test methods and that it conforms to NFPA r equirements.
D. Hardware for application on metal and wood doors and frames shall be made to standard templates. Furnish templates to th e fabricator of these items in sufficient time so as not to delay t he construction.
E. The following items shall be of the same manufac turer, except as otherwise specified:
1. Mortise locksets.
2. Hinges for hollow metal and wood doors.
3. Surface applied overhead door closers.
4. Exit devices.
5. Floor closers.
DOOR HARDWARE 08 71 00-2
1.4 WARRANTY
A. Automatic door operators shall be subject to the terms of FAR Clause
52.246-21, except that the Warranty period shall be two years in lieu of one year for all items except as noted below:
1. Locks, latchsets, and panic hardware: 5 years.
2. Door closers and continuous hinges: 10 years.
1.5 MAINTENANCE MANUALS
A. In accordance with Section 01 00 00, GENERAL REQ UIREMENTS Article titled "INSTRUCTIONS", furnish maintenance manuals and instructions on all door hardware. Provide installation instruction s with the submittal documentation.
1.6 SUBMITTALS
A. Submittals shall be in accordance with Section 0 1 33 23, SHOP DRAWINGS, PRODUCT DATA AND SAMPLES. Submit 6 copies of the sc hedule per Section
01 33 23. Submit 2 final copies of the final approv ed schedules to VAMC
Locksmith as record copies (VISN Locksmith if the V AMC does not have a locksmith).
B. Hardware Schedule: Prepare and submit hardware s chedule in the following form:
Hardware Item
Quantity Size Reference Publication Type No.
Finish Mfr.
Name and Catalog No.
Key Control Symbols
UL Mark (if fire rated and listed)
ANSI/BHMA
Finish Designation
C. Samples and Manufacturers' Literature:
1. Samples: All hardware items (proposed for the pr oject) that have not been previously approved by Builders Hardware Manuf acturers
Association shall be submitted for approval. Tag an d mark all items with manufacturer's name, catalog number and projec t number.
2. Samples are not required for hardware listed in the specifications by manufacturer's catalog number, if the contractor proposes to use the manufacturer's product specified.
D. Certificate of Compliance and Test Reports: Subm it certificates that hardware conforms to the requirements specified her ein. Certificates
DOOR HARDWARE 08 71 00-3
shall be accompanied by copies of reports as refere nced. The testing shall have been conducted either in the manufacture r's plant and certified by an independent testing laboratory or c onducted in an independent laboratory, within four years of submit tal of reports for approval.
1.7 DELIVERY AND MARKING
A. Deliver items of hardware to job site in their o riginal containers, complete with necessary appurtenances including scr ews, keys, and instructions. Tag one of each different item of har dware and deliver to
Resident Engineer for reference purposes. Tag shall identify items by
Project Specification number and manufacturer's cat alog number. These items shall remain on file in Resident Engineer's o ffice until all other similar items have been installed in project, at which time the
Resident Engineer will deliver items on file to Con tractor for installation in predetermined locations on the proj ect.
1.8 PREINSTALLATION MEETING
A. Convene a preinstallation meeting not less than 30 days before start of installation of door hardware. Require attendance of parties directly affecting work of this section, including Contracto r and Installer, Architect, Project Engineer and VA Locksmith, Hardw are Consultant, and
Hardware Manufacturer’s Representative. Review the following:
1. Inspection of door hardware.
2. Job and surface readiness.
3. Coordination with other work.
4. Protection of hardware surfaces.
5. Substrate surface protection.
6. Installation.
7. Adjusting.
8. Repair.
9. Field quality control.
10. Cleaning.
1.9 INSTRUCTIONS
A. Hardware Set Symbols on Drawings: Except for pro tective plates, door stops, mutes, thresholds and the like specified her ein, hardware requirements for each door are indicated on drawing s by symbols.
Symbols for hardware sets consist of letters (e.g., "HW") followed by a number. Each number designates a set of hardware it ems applicable to a door type.
DOOR HARDWARE 08 71 00-4
B. Keying: All cylinders shall be keyed into existi ng Great Grand Master
Key System. Provide removable core cylinders that a re removable only with a special key or tool without disassembly of k nob or lockset.
Cylinders shall be 7 pin type. Keying information shall be furnished at a later date by the Resident Engineer.
1.10 APPLICABLE PUBLICATIONS
A. The publications listed below form a part of thi s specification to the extent referenced. The publications are referenced in the text by the basic designation only. In text, hardware items are referred to by series, types, etc., listed in such specifications and standards, except as otherwise specified.
B. American Society for Testing and Materials (ASTM ):
F883-04.................Padlocks
E2180-07................Standard Test Method for De termining the
Activity of Incorporated Antimicrobial Agent(s)
In Polymeric or Hydrophobic Materials
C. American National Standards Institute/Builders H ardware Manufacturers
Association (ANSI/BHMA):
A156.1-06...............Butts and Hinges
A156.2-03...............Bored and Pre-assembled Loc ks and Latches
A156.3-08...............Exit Devices, Coordinators, and Auto Flush
Bolts
A156.4-08...............Door Controls (Closers)
A156.5-01(R2010)........Cylinders and Input Devices for Locks.
A156.6-05...............Architectural Door Trim
A156.8-05...............Door Controls-Overhead Stop s and Holders
A156.12-05 .............Interconnected Locks and La tches
A156.13-05..............Mortise Locks and Latches S eries 1000
A156.14-07 .............Sliding and Folding Door Ha rdware
A156.15-06..............Release Devices-Closer Hold er, Electromagnetic and Electromechanical
A156.16-08..............Auxiliary Hardware
A156.17-04 .............Self-Closing Hinges and Piv ots
A156.18-06..............Materials and Finishes
A156.20-06 .............Strap and Tee Hinges, and H asps
A156.21-09..............Thresholds
A156.22-05..............Door Gasketing and Edge Sea l Systems
DOOR HARDWARE 08 71 00-5
A156.23-04..............Electromagnetic Locks
A156.24-03..............Delayed Egress Locking Syst ems
A156.25-07 .............Electrified Locking Devices
A156.26-06..............Continuous Hinges
A156.28-07 .............Master Keying Systems
A156.29-07 .............Exit Locks and Alarms
A156.30-03 .............High Security Cylinders
A156.31-07 .............Electric Strikes and Frame Mounted Actuators
A250.8-03...............Standard Steel Doors and Fr ames
D. National Fire Protection Association (NFPA):
80-10...................Fire Doors and Fire Windows
101-09..................Life Safety Code
E. Underwriters Laboratories, Inc. (UL):
Building Materials Directory (2008)
PART 2 - PRODUCTS
2.1 BUTT HINGES
A. ANSI A156.1. Provide only three-knuckle hinges, except five-knuckle where the required hinge type is not available in a three-knuckle version (e.g., some types of swing-clear hinges). T he following types of butt hinges shall be used for the types of doors listed, except where otherwise specified:
1. Exterior Doors: Type A2112/A5112 for doors 900 m m (3 feet) wide or less and Type A2111/A5111 for doors over 900 mm (3 feet) wide.
Hinges for exterior outswing doors shall have non-r emovable pins.
Hinges for exterior fire-rated doors shall be of st ainless steel material.
2. Interior Doors: Type A8112/A5112 for doors 900 m m (3 feet) wide or less and Type A8111/A5111 for doors over 900 mm (3 feet) wide.
Hinges for doors exposed to high humidity areas (sh ower rooms, toilet rooms, kitchens, janitor rooms, etc. shall b e of stainless steel material.
B. Provide quantity and size of hinges per door lea f as follows:
1. Doors up to 1210 mm (4 feet) high: 2 hinges.
2. Doors 1210 mm (4 feet) to 2260 mm (7 feet 5 inches) high: 3 hinges minimum.
3. Doors greater than 2260 mm (7 feet 5 inches) high: 4 hinges.
4. Doors up to 900 mm (3 feet) wide, standard weight: 114 mm x 114 mm
(4-1/2 inches x 4-1/2 inches) hinges.
DOOR HARDWARE 08 71 00-6
5. Doors over 900 mm (3 feet) to 1065 mm (3 feet 6 inc hes) wide, standard weight: 127 mm x 114 mm (5 inches x 4-1/2 inches).
6. Doors over 1065 mm (3 feet 6 inches) to 1210 mm (4 feet), heavy weight: 127 mm x 114 mm (5 inches x 4-1/2 inches).
7. Provide heavy-weight hinges where specified.
8. At doors weighing 330 kg (150 lbs.) or more, furnis h 127 mm (5 inch) high hinges.
C. See Articles "MISCELLANEOUS HARDWARE" and "HARDW ARE SETS" for pivots and hinges other than butts specified above and con tinuous hinges specified below.
2.2 CONTINUOUS HINGES
A. ANSI/BHMA A156.26, Grade 1-600.
1. Listed under Category N in BHMA's "Certified Pro duct Directory."
B. General: Minimum 0.120-inch- (3.0-mm-) thick, h inge leaves with minimum overall width of 4 inches (102 mm); fabrica ted to full height of door and frame and to template screw locations; with components finished after milling and drilling are complete
C. Continuous, Barrel-Type Hinges: Hinge with knuc kles formed around a
Teflon-coated 6.35mm (0.25-inch) minimum diameter p in that extends entire length of hinge.
1. Base Metal for Exterior Hinges: Stainless steel.
2. Base Metal for Interior Hinges: Stainless steel.
3. Base Metal for Hinges for Fire-Rated Assemblies: Stainless steel.
4. Provide with non-removable pin (hospital tip opt ion) at lockable outswing doors.
5. Where required to clear adjacent casing, trim, a nd wall conditions and allow full door swing, provide wide throw hinge s of minimum width required.
6. Provide with manufacturer’s cut-outs for separat e mortised power transfers and/or mortised automatic door bottoms wh ere they occur.
7. Where thru-wire power transfers are integral to the hinge, provide hinge with easily removable portion to allow easy a ccess to wiring connections.
8. Where models are specified that provide an integ ral wrap-around edge guard for the hinge edge of the door, provide manuf acturer’s adjustable threaded stud and machine screw mechanis m to allow the door to be adjusted within the wrap-around edge gua rd.
DOOR HARDWARE 08 71 00-7
2.3 DOOR CLOSING DEVICES
A. Closing devices shall be products of one manufac turer and coordinated with the campus requirements.
2.4 OVERHEAD CLOSERS
A. Conform to ANSI A156.4, Grade 1.
B. Closers shall conform to the following:
1. The closer shall have minimum 50 percent adjusta ble closing force over minimum value for that closer and have adjusta ble hydraulic back check effective between 60 degrees and 85 degr ees of door opening.
2. Where specified, closer shall have hold-open fea ture.
3. Size Requirements: Provide multi-size closers, s izes 1 through 6, except where multi-size closer is not available for the required application.
4. Material of closer body shall be forged or cast.
5. Arm and brackets for closers shall be steel, mal leable iron or high strength ductile cast iron.
6. Where closers are exposed to the exterior or are mounted in rooms that experience high humidity, provide closer body and arm assembly of stainless steel material.
7. Closers shall have full size metal cover; plasti c covers will not be accepted.
8. Closers shall have adjustable hydraulic back-che ck, separate valves for closing and latching speed, adjustable back-che ck positioning valve, and adjustable delayed action valve.
9. Provide closers with any accessories required fo r the mounting application, including (but not limited to) drop pl ates, special soffit plates, spacers for heavy-duty parallel arm fifth screws, bull-nose or other regular arm brackets, longer or shorter arm assemblies, and special factory templating. Provid e special arms, drop plates, and templating as needed to allow moun ting at doors with overhead stops and/or holders.
10. Closer arms or backcheck valve shall not be use d to stop the door from overswing, except in applications where a sepa rate wall, floor, or overhead stop cannot be used.
11. Provide parallel arm closers with heavy duty ri gid arm.
DOOR HARDWARE 08 71 00-8
12. Where closers are to be installed on the push s ide of the door, provide parallel arm type except where conditions r equire use of top jamb arm.
13. Provide all surface closers with the same body attachment screw pattern for ease of replacement and maintenance.
14. All closers shall have a 1 ½” (38mm) minimum pi ston diameter.
2.5 DOOR STOPS
A. Conform to ANSI A156.16.
B. Provide door stops wherever an opened door or an y item of hardware thereon would strike a wall, column, equipment or o ther parts of building construction. For concrete, masonry or qua rry tile construction, use lead expansion shields for mounti ng door stops.
C. Provide floor stops (Type L02141 or L02161 in of fice areas; Type L02121 x 3 screws into floor elsewhere. Wall bumpers, wher e used, must be installed to impact the trim or the door within the leading half of its width. Floor stops, where used, must be installed within 4-inches of the wall face and impact the door within the leadin g half of its width.
D. Where drywall partitions occur, use floor stops, Type L02141 or L02161 in office areas, Type L02121 elsewhere.
E. Provide appropriate door mounted stop on doors i n individual toilets where floor or wall mounted stops cannot be used.
F. Provide door stops on doors where combination cl oser magnetic holders are specified, except where wall stops cannot be us ed or where floor stops cannot be installed within 4-inches of the wa ll.
2.6 OVERHEAD DOOR STOPS AND HOLDERS
A. Conform to ANSI Standard A156.8. Overhead holder s shall be of sizes recommended by holder manufacturer for each width o f door. Set overhead holders for 110 degree opening, unless limited by b uilding construction or equipment. Provide Grade 1 overhead concealed sl ide type: stop-only at rated doors and security doors, hold-open type w ith exposed hold-open on/off control at all other doors requiring ov erhead door stops.
2.7 FLOOR DOOR HOLDERS
A. Conform to ANSI Standard A156.16. Provide extens ion strikes for Types
L01301 and L01311 holders where necessary.
2.8 LOCKS AND LATCHES
A. Conform to ANSI A156.2. Locks and latches for do ors 45 mm (1-3/4 inch) thick or over shall have beveled fronts. Lock cylin ders shall have not
DOOR HARDWARE 08 71 00-9
less than seven pins. Cylinders for all locksets sh all be removable core type. Cylinders shall be furnished with constr uction removable cores and construction master keys. Cylinder shall be removable by special key or tool. Construct all cores so that th ey will be interchangeable into the core housings of all morti se locks, rim locks, cylindrical locks, and any other type lock included in the Great Grand
Master Key System. Disassembly of lever or lockset shall not be required to remove core from lockset. All locksets or latches on double doors with fire label shall have latch bolt with 19 mm (3/4 inch) throw, unless shorter throw allowed by the door man ufacturer’s fire label. Provide temporary keying device or construct ion core of allow opening and closing during construction and prior t o the installation of final cores.
B. In addition to above requirements, locks and lat ches shall comply with following requirements:
1. Mortise Lock and Latch Sets: Conform to ANSI/BHM A A156.13. Mortise locksets shall be series 1000, minimum Grade 2. All locksets and latchsets, except on designated doors in Psychiatri c (Mental Health) areas, shall have lever handles fabricated from cas t stainless steel. Provide sectional (lever x rose) lever desi gn matching the existing hospital lever standard. No substitute lev er material shall be accepted. All locks and latchsets shall be furni shed with 122.55 mm (4-7/8-inch) curved lip strike and wrought box. At outswing pairs with overlapping astragals, provide flat lip strip with 21mm (7/8-inch) lip-to-center dimension. Lock function F02 s hall be furnished with emergency tools/keys for emergency entrance. A ll lock cases installed on lead lined doors shall be lead lined b efore applying final hardware finish. Furnish armored fronts for a ll mortise locks.
Where mortise locks are installed in high-humidity locations or where exposed to the exterior on both sides of the opening, provide non-ferrous mortise lock case.
2. Cylindrical Lock and Latch Sets: levers shall me et ADA (Americans with Disabilities Act) requirements. Cylindrical lo cksets shall be series 4000 Grade I. All locks and latchsets shall be furnished with
122.55 mm (4-7/8-inch) curved lip strike and wrough t box. At outswing pairs with overlapping astragals, provide flat lip strip with 21mm (7/8-inch) lip-to-center dimension. Prov ide lever design
DOOR HARDWARE 08 71 00-10
to match design selected by Architect or to match e xisting lever design. Where two turn pieces are specified for lo ck F76, turn piece on inside knob shall lock and unlock inside k nob, and turn piece on outside knob shall unlock outside knob whe n inside knob is in the locked position. (This function is intended to allow emergency entry into these rooms without an emergen cy key or any special tool.)
3. Auxiliary locks shall be as specified under hard ware sets and conform to ANSI A156.5.
4. Locks on designated doors in Psychiatric (Mental Health) areas shall be paddle type with arrow projection covers and be UL Listed.
Provide these locks with paddle in the down positio n on both sides of the door. Locks shall be fabricated of wrought s tainless steel.
5. Privacy locks in non-mental-health patient rooms shall have an inside thumbturn for privacy and an outside thumbtu rn for emergency entrance. Single occupancy patient privacy doors s hall typically swing out; where such doors cannot swing out, provi de center-pivoted doors with rescue hardware (see HW-2B).
2.9 PUSH-BUTTON COMBINATION LOCKS
A. ANSI/BHMA A156.5, Grade 1. Battery operated push button entry.
B. Construction: Heavy duty mortise lock housing c onforming to ANSI/BHMA
A156.13, Grade 1. Lever handles and operating comp onents in compliance with the UFAS and the ADA Accessibility Guidelines. Match lever handles of locks and latchsets on adjacent doors.
C. Special Features: Key override to permit a mast er keyed security system and a pushbutton security code activated pas sage feature to allow access without using the entry code.
2.10 ELECTROMAGNETIC LOCKS
A. ANSI/BHMA A156.23; electrically powered, of stre ngth and configuration indicated; with electromagnet attached to frame and armature plate attached to door. Listed under Category E in BHMA's "Certified Product
Directory."
1. Type: Full exterior or full interior, as requir ed by application indicated.
2. Strength Ranking: 1500 lbf (6672 N).
3. Inductive Kickback Peak Voltage: Not more than 0.
DOOR HARDWARE 08 71 00-11
4. Residual Magnetism: Not more than 0 lbf (0 N) to separate door from magnet.
B. Delayed-Egress Locks: BHMA A156.24. Listed under Category G in BHMA's
"Certified Product Directory".
1. Means of Egress Doors: Lock releases within 15 s econds after applying a force not more than 15 lbf (67 N) for no t more than 3 seconds, as required by NFPA 101.
2. Security Grade: Activated from secure side of do or by initiating device.
3. Movement Grade: Activated by door movement as in itiating device.
4. The lock housing shall not project more than 4-i nches (101mm) from the underside of the frame head stop.
2.11 ELECTRIC STRIKES
A. ANSI/ BHMA A156.31 Grade 1.
B. General: Use fail-secure electric strikes at fi re-rated doors.
2.12 KEYS
A. Stamp all keys with change number and key set sy mbol. Furnish keys in quantities as follows:
Locks/Keys Quantity
Cylinder locks 2 keys each
Cylinder lock change key blanks
100 each different key way
Master-keyed sets 6 keys each
Grand Master sets 6 keys each
Great Grand Master set 5 keys
Control key 2 keys
B. Psychiatric keys shall be cut so that first two bittings closest to the key shoulder are shallow to provide greater strengt h at point of greatest torque.
2.13 KEY CABINET
A. ANSI Standard A156.5. Provide key cabinet made o f cold rolled, 1.2 mm
(0.0478 inch) thick furniture steel electro-welded. Doors shall have
"no sag" continuous brass-pin piano type hinge and be equipped with chrome plated locking door handles, hook cam and me chanical pushbutton door lock. Key Cabinet and Key Control System shal l accommodate all keys for this project plus 25 percent. Provide min imum number of
DOOR HARDWARE 08 71 00-12
multiple cabinets where a single cabinet of largest size will not accommodate the required number of keys.
B. Key tags shall consist of two sets: Permanent se lf-locking and loan key snaphook type with tag colors as follows: Red fiber marker of the permanent self-locking type approximately 32 mm (1- 1/4 inch) in diameter engraved with the legend "FILE KEY MUST NO T BE LOANED." Also furnish for each hook a white cloverleaf key marker with snap-hooks engraved with the legend "LOAN KEY."
C. The manufacturer of the lock cylinders and locks shall attach a key tag to keys of each lock cylinder and shall mark thereo n the respective item number and key change number. Provide each gro up of keys in a key gathering envelope (supplied by Key Cabinet Manufac turer) in which the lock manufacturer shall include the following infor mation: Item number, key change number and door number. The contractor s hall furnish the Key
Cabinet Manufacturer the hardware and keying schedu les and change keys.
D. The Key Cabinet Manufacturer shall set up a thre e-way cross index system, including master keys, listing the keys alp habetically, the hooks numerically and the key changes numerically o n different colored index cards. Index cards shall be typewritten and i nserted in a durable binder. Attach the keys to the two sets of numbered tags supplied with the cabinet. (The permanent tag and the loan key ta g). Instruct the owner in proper use of the system. Install cabinet as directed by the
Resident Engineer.
2.14 ARMOR PLATES, KICK PLATES, MOP PLATES AND DOOR EDGING
A. Conform to ANSI Standard A156.6.
B. Provide protective plates and door edging as spe cified below:
1. Kick plates, mop plates and armor plates of meta l, Type J100 series.
2. Provide kick plates and mop plates where specifi ed. Kick plates shall be 254 mm (10 inches) or 305 mm (12 inches) h igh. Mop plates shall be 152 mm (6 inches) high. Both kick and mop plates shall be minimum 1.27 mm (0.050 inches) thick. Provide kick and mop plates beveled on all 4 edges (B4E). On push side of door s where jamb stop extends to floor, make kick plates 38 mm (1-1/2 inc hes) less than width of door, except pairs of metal doors which sh all have plates
25 mm (1 inch) less than width of each door. Extend all other kick and mop plates to within 6 mm (1/4 inch) of each ed ge of doors. Kick
DOOR HARDWARE 08 71 00-13
and mop plates shall butt astragals. For jamb stop requirements, see specification sections pertaining to door frames.
3. Kick plates and/or mop plates are not required o n following door sides:
a. Armor plate side of doors;
b. Exterior side of exterior doors;
c. Closet side of closet doors;
d. Both sides of aluminum entrance doors.
4. Armor plates for doors are listed under Article "Hardware Sets".
Armor plates shall be thickness as noted in the har dware set, 875 mm
(35 inches) high and 38 mm (1-1/2 inches) less than width of doors, except on pairs of metal doors. Provide armor plate s beveled on all
4 edges (B4E). Plates on pairs of metal doors shal l be 25 mm (1 inch) less than width of each door. Where top of in termediate rail of door is less than 875 mm (35 inches) from door b ottom, extend armor plates to within 13 mm (1/2 inch) of top of i ntermediate rail.
On doors equipped with panic devices, extend armor plates to within
13 mm (1/2 inch) of panic bolt push bar.
5. Where louver or grille occurs in lower portion o f doors, substitute stretcher plate and kick plate in place of armor pl ate. Size of stretcher plate and kick plate shall be 254 mm (10 inches) high.
6. Provide stainless steel edge guards where so spe cified at wood doors. Provide mortised type instead of surface typ e except where door construction and/or ratings will not allow. P rovide edge guards of bevel and thickness to match wood door. Provide edge guards with factory cut-outs for door hardware that must be installed through or extend through the edge guard. Provide full-height edge guards except where door rating does no t allow; in such cases, provide edge guards to height of bottom of t ypical lockset armor front. Forward edge guards to wood door manu facturer for factory installation on doors.
2.15 EXIT DEVICES
A. Conform to ANSI Standard A156.3. Exit devices sh all be Grade 1; type and function are specified in hardware sets. Provid e flush with finished floor strikes for vertical rod exit device s in interior of building. Trim shall have cast satin stainless stee l lever handles of design similar to locksets, unless otherwise specif ied. Provide key
DOOR HARDWARE 08 71 00-14
cylinders for keyed operating trim and, where speci fied, cylinder dogging.
B. Surface vertical rod panics shall only be provid ed less bottom rod;
provide fire pins as required by exit device and do or fire labels. Do not provide surface vertical rod panics at exterior doors.
C. Concealed vertical rod panics shall be provided less bottom rod at interior doors, unless lockable or otherwise specif ied; provide fire pins as required by exit device and door fire label s. Where concealed vertical rod panics are specified at exterior doors , provide with both top and bottom rods.
D. Where removable mullions are specified at pairs with rim panic devices, provide mullion with key-removable feature.
E. At non-rated openings with panic hardware, provi de panic hardware with key cylinder dogging feature.
F. Exit devices for fire doors shall comply with Un derwriters
Laboratories, Inc., requirements for Fire Exit Hard ware. Submit proof of compliance.
2.16 FLUSH BOLTS (LEVER EXTENSION)
A. Conform to ANSI A156.16. Flush bolts shall be Ty pe L24081 unless otherwise specified. Furnish proper dustproof strik es conforming to
ANSI A156.16, for flush bolts required on lower par t of doors.
B. Lever extension manual flush bolts shall only be used at non-fire-rated pairs for rooms only accessed by maintenance person nel.
C. Face plates for cylindrical strikes shall be rec tangular and not less than 25 mm by 63 mm (1 inch by 2-1/2 inches).
D. Friction-fit cylindrical dustproof strikes with circular face plate may be used only where metal thresholds occur.
E. Provide extension rods for top bolt where door h eight exceeds 2184 mm
(7 feet 2 inches).
2.17 FLUSH BOLTS (AUTOMATIC)
A. Conform to ANSI A156.3. Dimension of flush bolts shall conform to ANSI
A115. Bolts shall conform to Underwriters Laborator ies, Inc., requirements for fire door hardware. Flush bolts sh all automatically latch and unlatch. Furnish dustproof strikes confor ming to ANSI A156.16 for bottom flushbolt. Face plates for dustproof str ike shall be rectangular and not less than 38 mm by 90 mm (1-1/2 by 3-1/2 inches).
B. At interior doors, provide auto flush bolts less bottom bolt, unless otherwise specified, except at wood pairs with fire -rating greater than
DOOR HARDWARE 08 71 00-15
20 minutes; provide fire pins as required by auto f lush bolt and door fire labels.
2.18 DOOR PULLS WITH PLATES
A. Conform to ANSI A156.6. Pull Type J401, 152 mm ( 6 inches) high by 19 mm
(3/4 inches) diameter with plate Type J302, 90 mm b y 350 mm (3-1/2 inches by 14 inches), unless otherwise specified. P rovide pull with projection of 70 mm (2 3/4 inches) and a clearance of 51 mm (2 inches).
Cut plates of door pull plate for cylinders, or tur n pieces where required.
2.19 PUSH PLATES
A. Conform to ANSI A156.6. Metal, Type J302, 200 mm (8 inches) wide by 350 mm (14 inches) high. Provide metal Type J302 plates 100 mm (4 inches wide by 350 mm (14 inches) high) where push plates are specified for doors with stiles less than 200 mm (8 inches) wide. Cut plates for cylinders, and turn pieces where required.
2.20 COMBINATION PUSH AND PULL PLATES
A. Conform to ANSI 156.6. Type J303, stainless stee l 3 mm (1/8 inch) thick, 80 mm (3-1/3 inches) wide by 800 mm (16 inch es) high), top and bottom edges shall be rounded. Secure plates to woo d doors with 38 mm
(1-1/2 inch) long No. 12 wood screws. Cut plates fo r turn pieces, and cylinders where required. Pull shall be mounted dow n.
2.21 COORDINATORS
A. Conform to ANSI A156.16. Coordinators, when spec ified for fire doors, shall comply with Underwriters Laboratories, Inc., requirements for fire door hardware. Coordinator may be omitted on e xterior pairs of doors where either door will close independently re gardless of the position of the other door. Coordinator may be omit ted on interior pairs of non-labeled open where open back strike is used. Open back strike shall not be used on labeled doors. Paint co ordinators to match door frames, unless coordinators are plated. Provi de bar type coordinators, except where gravity coordinators are required at acoustic pairs. For bar type coordinators, provide filler bars for full width and, as required, brackets for push-side surface mounted closers, overhead stops, and vertical rod panic str ikes.
2.22 THRESHOLDS
A. Conform to ANSI A156.21, mill finish extruded al uminum, except as otherwise specified. In existing construction, thre sholds shall be installed in a bed of sealant with ¼-20 stainless s teel machine screws
DOOR HARDWARE 08 71 00-16
and expansion shields. In new construction, embed a luminum anchors coated with epoxy in concrete to secure thresholds. Furnish thresholds for the full width of the openings.
B. For thresholds at elevators entrances see other sections of specifications.
C. At exterior doors and any interior doors exposed to moisture, provide threshold with non-slip abrasive finish.
D. Provide with miter returns where threshold exten ds more than 12 mm (0.5 inch) from fame face.
2.23 AUTOMATIC DOOR BOTTOM SEAL AND RUBBER GASKET FOR LIGHT PROOF OR SOUND
CONTROL DOORS
A. Conform to ANSI A156.22. Provide mortise or und er-door type, except where not practical. For mortise automatic door bo ttoms, provide type specific for door construction (wood or metal).
2.24 WEATHERSTRIPS (FOR EXTERIOR DOORS)
A. Conform to ANSI A156.22. Air leakage shall not t o exceed 0.50 CFM per foot of crack length (0.000774m 3/s/m).
2.25 MISCELLANEOUS HARDWARE
A. Access Doors (including Sheet Metal, Screen and Woven Wire Mesh Types):
Except for fire-rated doors and doors to Temperatur e Control Cabinets, equip each single or double metal access door with Lock Type E76213, conforming to ANSI A156.5. Key locks as directed. S hip lock prepaid to the door manufacturer. Hinges shall be provided by door manufacturer.
B. Cylinders for Various Partitions and Doors: Key cylinders same as entrance doors of area in which partitions and door occur, except as otherwise specified. Provide cylinders to operate l ocking devices where specified for following partitions and doors:
1. Folding doors and partitions.
2. Wicket door (in roll-up door assemblies).
3. Slide-up doors.
4. Swing-up doors.
5. Fire-rated access doors-Engineer's key set.
6. Doors from corridor to electromagnetic shielded room.
7. Day gate on vault door.
C. Mutes: Conform to ANSI A156.16. Provide door mut es or door silencers
Type L03011 or L03021, depending on frame material, of white or light gray color, on each steel or wood door frame, excep t at fire-rated frames, lead-lined frames and frames for sound-resi stant, lightproof
DOOR HARDWARE 08 71 00-17
and electromagnetically shielded doors. Furnish 3 m utes for single doors and 2 mutes for each pair of doors, except do uble-acting doors.
Provide 4 mutes or silencers for frames for each Du tch type door.
Provide 2 mutes for each edge of sliding door which would contact door frame.
2.26 PADLOCKS FOR VARIOUS DOORS, GATES AND HATCHES
A. ASTM E883, size 50 mm (2 inch) wide chain; furni sh extended shackles as required by job conditions. Provide padlocks, with key cylinders, for each door in following areas as noted.
B. Key padlocks as follows:
1. Constant Temperature Rooms in Research Departmen ts: Research
Laboratory Set.
2. Cold Room in Morgue Department: Autopsy Set.
3. Refrigerators in Canteen Department: Canteen Sto rage Set.
4. All Refrigerator Rooms in Main Kitchen Departmen t: Kitchen Storage
Set.
5. Chain Link Fence Gates for Electrical Substation and other Fenced
Buildings or Areas: Engineer's set, except as other wise specified.
6. Chain Link Fence Gates for Oxygen Storage Buildi ngs: Maintenance supply set.
7. Roof Access and Scuttles: Engineer's set.
8. Hinged Wicket in Post Office Partitions: Post Of fice set.
C. Omit padlocks on communicating refrigerator door s.
2.27 THERMOSTATIC TEMPERATURE CONTROL VALVE CABINETS
A. Where lock is shown, equip each cabinet door (me tal) with lock Type
E06213, conforming to ANSI A156.5. Key locks in Key Sets approved by
Contracting Officer. See mechanical drawings and sp ecifications for location of cabinets.
B. Cabinet manufacturer shall supply the hinges, bo lts and pulls. Ship locks to cabinet manufacturer for installation.
2.28 HINGED WIRE GUARDS (FOR WINDOWS, DOORS AND TRANSOMS) AND WIRE PARTITION
DOORS
A. Butt hinges, type A8133 (special swaging) 100 mm by 90 mm (4 inches by
3-1/2 inches), Finish US2C.
1. 3 hinges for guards over 1060 mm (3-1/2 feet) hi gh.
2. 2 hinges for guards less than 1060 mm (3-1/2 fee t) high.
B. Conform to ANSI A156.5. Lock Type E06081 for gua rds and Type E06061 for partitions.
DOOR HARDWARE 08 71 00-18
1. Keying: Except as noted otherwise, key locks lik e entrance door or space wherein guards and partitions are located exc ept as otherwise specified.
2. Key locks for partitions enclosing mechanical an d electrical equipment in Engineer's Set. (See detailed drawings for number of locks and butt hinges required for each guard).
2.29 FINISHES
A. Exposed surfaces of hardware shall have ANSI A15 6.18, finishes as specified below. Finishes on all hinges, pivots, cl osers, thresholds, etc., shall be as specified below under "Miscellane ous Finishes." For field painting (final coat) of ferrous hardware, se e Section 09 91 00, PAINTING.
B. 626 or 630: All surfaces on exterior and interio r of buildings, except where other finishes are specified.
C. Miscellaneous Finishes:
1. Hinges --exterior doors: 626 or 630.
2. Hinges --interior doors: 652 or 630.
3. Pivots: Match door trim.
4. Door Closers: Factory applied paint finish. Dull or Satin Aluminum color.
5. Thresholds: Mill finish aluminum.
6. Cover plates for floor hinges and pivots: 630.
7. Other primed steel hardware: 600.
D. Hardware Finishes for Existing Buildings: U.S. S tandard finishes shall match finishes of hardware in (similar) existing sp aces except where otherwise specified.
E. Special Finish: Exposed surfaces of hardware for dark bronze anodized aluminum doors shall have oxidized oil rubbed bronz e finish (dark bronze) finish on door closers shall closely match doors.
F. Anti-microbial Coating: All hand-operated hardwa re (levers, pulls, push bars, push plates, paddles, and panic bars) shall b e provided with an anti-microbial/anti-fungal coating that has passed ASTM E2180 tests.
Coating to consist of ionic silver (Ag+). Silver i ons surround bacterial cells, inhibiting growth of bacteria, mol d, and mildew by blockading food and respiration supplies.
DOOR HARDWARE 08 71 00-19
2.30 BASE METALS
A. Apply specified U.S. Standard finishes on differ ent base metals as following:
Finish Base Metal
652 Steel
626 Brass or bronze
630 Stainless steel
PART 3 - EXECUTION
3.1 HARDWARE HEIGHTS
A. For existing buildings locate hardware on doors at heights to match existing hardware. The Contractor shall visit the s ite, verify location of existing hardware and submit locations to VA Res ident Engineer for approval.
B. Hardware Heights from Finished Floor:
1. Exit devices centerline of strike (where applica ble) 1024 mm (40-
5/16 inches).
2. Locksets and latch sets centerline of strike 102 4 mm (40-5/16 inches).
3. Deadlocks centerline of strike 1219 mm (48 inche s).
4. Hospital arm pull 1168 mm (46 inches) to centerl ine of bottom supporting bracket.
5. Centerline of door pulls to be 1016 mm (40 inche s).
6. Push plates and push-pull shall be 1270 mm (50 i nches) to top of plate.
7. Push-pull latch to be 1024 mm (40-5/16 inches) t o centerline of strike.
8. Locate other hardware at standard commercial hei ghts. Locate push and pull plates to prevent conflict with other hard ware.
3.2 INSTALLATION
A. Closer devices, including those with hold-open f eatures, shall be equipped and mounted to provide maximum door openin g permitted by building construction or equipment. Closers shall b e mounted on side of door inside rooms, inside stairs, and away from cor ridors. At exterior doors, closers shall be mounted on interior side. W here closers are mounted on doors they shall be mounted with sex nut s and bolts; foot shall be fastened to frame with machine screws.
DOOR HARDWARE 08 71 00-20
B. Hinge Size Requirements:
Door Thickness Door Width Hinge Height
45 mm (1-3/4 inch) 900 mm (3 feet) and less 113 mm (4-1/2 inches)
45 mm (1-3/4 inch) Over 900 mm (3 feet) but not more than 1200 mm (4 feet)
125 mm (5 inches)
35 mm (1-3/8 inch) (hollow core wood doors)
Not over 1200 mm (4 feet) 113 mm (4-1/2 inches)
C. Hinge leaves shall be sufficiently wide to allow doors to swing clear of door frame trim and surrounding conditions.
D. Where new hinges are specified for new doors in existing frames or existing doors in new frames, sizes of new hinges s hall match sizes of existing hinges. Existing hinges shall not be reuse d on door openings having new doors and new frames. Coordinate prepara tion for hinge cut-outs and screw-hole locations on doors and frames.
E. Hinges Required Per Door:
Doors 1500 mm (5 ft) or less in height 2 butts
Doors over 1500 mm (5 ft) high and not over 2280 mm (7 ft 6 in) high
3 butts
Doors over 2280 mm (7 feet 6 inches) high 4 butts
Dutch type doors 4 butts
Doors with spring hinges 1370 mm (4 feet 6 inches) high or less
2 butts
Doors with spring hinges over 1370 mm (4 feet 6 inc hes) 3 butts
F. Fastenings: Suitable size and type and shall har monize with hardware as to material and finish. Provide machine screws and lead expansion shields to secure hardware to concrete, ceramic or quarry floor tile, or solid masonry. Fiber or rawl plugs and adhesives are not permitted.
All fastenings exposed to weather shall be of nonfe rrous metal.
G. After locks have been installed; show in presenc e of Resident Engineer that keys operate their respective locks in accorda nce with keying requirements. (All keys, Master Key level and above shall be sent
Registered Mail to the Medical Center Director alon g with the bitting list. Also a copy of the invoice shall be sent to t he Resident Engineer for his records.) Installation of locks which do no t meet specified
DOOR HARDWARE 08 71 00-21
keying requirements shall be considered sufficient justification for rejection and replacement of all locks installed on project.
3.3 FINAL INSPECTION
A. Installer to provide letter to VA Resident/Proje ct Engineer that upon completion, installer has visited the Project and h as accomplished the following:
1. Re-adjust hardware.
2. Evaluate maintenance procedures and recommend ch anges or additions, and instruct VA personnel.
3. Identify items that have deteriorated or failed.
4. Submit written report identifying problems.
3.4 DEMONSTRATION
A. Demonstrate efficacy of mechanical hardware and electrical, and electronic hardware systems, including adjustment a nd maintenance procedures, to satisfaction of Resident/Project Eng ineer and VA
Locksmith.
3.5 HARDWARE SETS
A. Following sets of hardware correspond to hardwar e symbols shown on drawings. Only those hardware sets that are shown o n drawings will be required. Disregard hardware sets listed in specifi cations but not shown on drawings.
B. Hardware Consultant working on a project will be responsible for providing additional information regarding these ha rdware sets. The numbers shown in the following sets come from BHMA standards.
ELECTRIC HARDWARE ABBREVIATIONS LEGEND:
ADO = Automatic Door Operator
EMCH = Electro-Mechanical Closer-Holder
MHO = Magnetic Hold-Open (wall- or floor-mounted)
DOOR HARDWARE 08 71 00-22
INTERIOR SINGLE DOORS
HW-1
Each Door to Have: NON-RATED
1 Continuous Hinge
1 Door Pull w/ Plate J401 x J302
1 Push Plate J302
1 Kick Plate J102
1 Mop Plate (@ Inswing Doors) J103
1 Closer C02011/C02021
1 Floor Stop L02121 x 3 FASTENERS
3 Silencers L03011
HW-1B
Each Door to Have: NON-RATED/RATED
1 Continuous Hinge x INTEGRAL HINGE GUARD CHANNE L
X SWING-CLEAR X ADJUSTA-SCREWS
1 Hospital Latch F01 x PADDLES POINTING DOWN
1 Armor Plate J101 x 1.275 MM (0.050 INCH) THICK NESS
1 Edge Guard (@ Wood Doors) J208M / J211 (VERIFY), CUT: HARDWARE
1 Overhead Stop C01541-ADJUSTABLE
1 Set Seals R0Y164
NO CLOSER REQUIRED DUE TO EXEMPTION FOR PATIENT ROOM DOORS.
DOOR HARDWARE 08 71 00-23
HW-1L
1 Latchset F04
1 Kick Plate J102
1 Wall Stop L02101 CONVEX
1 Threshold J32300 x 57 MM WIDTH (2-1/4 INCHES)
1 Auto Door Bottom R0Y346 – HEAVY DUTY
2 Sets Self-Adhesive Seals R0Y154
HW-1M
1 Floor Closer C06011
2 Push Plates J302
2 Kick Plates J102
2 Edge Guard (@ Wood Doors) J209M / J212 (VERIFY)
1 Overhead Stop C01541-ADJUSTABLE
HW-1P
Each Lead-Lined Door to Have: NON-RATED
1 Floor Closer C6062
2 Push Plates J302 8” x 16”
2 Kick Plates J102
2 Edge Guard (@ Wood Doors) J209M / J212 (VERIFY)
1 Overhead Stop C01541-ADJUSTABLE
HW-2
Each Door to Have: RATED/NON-RATED
Hinges QUANTITY & TYPE AS REQUIRED
1 Keyed Privacy Indicator Lock F13 x OCCUPANCY INDI CATOR
1 Closer C02011/C02021
1 Kick Plate J102
1 Mop Plate (@ Inswing Doors) J103
1 Floor Stop L02121 x 3 FASTENERS
1 Set Self-Adhesive Seals R0Y154
STONE THRESHOLD BY OTHER TRADES.
DOOR HARDWARE 08 71 00-24
HW-2C
1 Privacy Lock F02-MOD X OCCUPANCY INDICATOR
1 Kick Plate J102
1 Mop Plate (@ Inswing Doors) J103
1 Wall Stop L02101 CONVEX
HW-2G
1 Keyed Privacy Indicator Lock F13 x OCCUPANCY INDI CATOR
1 Closer C02011/C02021
1 Kick Plate J102
1 Mop Plate (@ Inswing Doors) J103
1 Floor Stop L02121 x 3 FASTENERS
1 Auto Door Bottom R0Y346 – HEAVY DUTY
2 Set Self-Adhesive Seals R0Y154
HW-3E
1 Office Lock F04
1 Floor Stop L02121 x 3 FASTENERS
1 Set Self-Adhesive Seals R0Y154
1 Coat Hook L03121
OMIT COAT HOOK WHERE GLASS LITE PREVENTS INSTALLATI ON.
DOOR HARDWARE 08 71 00-25
HW-3G
1 Office Lock F04
1 Floor Stop L02121 x 3 FASTENERS
1 Coat Hook L03121
1 Door Viewer (Mental Health Only) L03221 – 190° (VIEW INTO CORRIDOR)
1 Threshold J32300 x 57 MM WIDTH (2-1/4 INCHES)
1 Auto Door Bottom R0Y346 – HEAVY DUTY
2 Sets Self-Adhesive Seals R0Y154
OMIT VIEWER IF DOOR PROVIDED WITH VISION LITE.
OMIT COAT HOOK WHERE GLASS LITE PREVENTS INSTALLATI ON.
HW-4
1 Classroom Lock F08
1 Overhead Stop C04541
DOOR HARDWARE 08 71 00-26
HW-4B
1 Public Restroom Lock F09
1 Closer C02011/C02021
1 Closer CO2051/CO2061
1 Kick Plate J102
1 Mop Plate (@ Inswing Doors) J103
1 Floor Stop (@ Outswing Doors) L02121 x 3 FASTENER S
1 Wall Stop (@ Inswing Doors) L02101 CONVEX
1 Threshold J32300 x 57 MM WIDTH (2-1/4 INCHES)
1 Auto Door Bottom R0Y346 – HEAVY DUTY
2 Sets Self-Adhesive Seals R0Y154
PROVIDE NON-HOLD-OPEN CLOSER AT TOILET ROOMS.
HW-4C
Each Door to Have: RATED
X ADJUSTA-SCREWS
1 Hospital Utility Lock F09 x PADDLES POINTING DOW N
1 Key Cylinder TYPE AS REQUIRED
1 Closer C02011/C02021
1 Armor Plate J101 x 1.275 MM (0.050 INCH) THICK NESS
1 Edge Guard (@ Wood Doors) J208M / J211 (VERIFY), CUT: HARDWARE
1 Overhead Stop C01541-ADJUSTABLE
1 Threshold J32300 x 57 MM WIDTH (2-1/4 INCHES)
1 Set Seals R0Y164
DOOR HARDWARE 08 71 00-27
HW-4F
1 Utility Lock F09
1 Closer C02011/C02021
1 Armor Plate J101 x 1.275 MM (0.050 INCH) THICK NESS
1 Edge Guard (@ Wood Doors) J208M / J211 (VERIFY), CUT: HARDWARE
1 Floor Stop (@ Outswing Doors) L02121 x 3 FASTENER S
1 Wall Stop (@ Inswing Doors) L02101 CONVEX
1 Set Self-Adhesive Seals R0Y154
HW-4G
1 Utility Lock F09
1 Closer (@ Rated Doors) C02011/C02021
1 Kick Plate J102
1 Floor Stop L02121 x 3 FASTENERS
1 Set Self-Adhesive Seals R0Y154
HW-4J
1 Utility Lock F09
1 Closer (@ Rated Doors) C02011/C02021
1 Kick Plate J102
1 Floor Stop L02121 x 3 FASTENERS
1 Threshold J32300 x 57 MM WIDTH (2-1/4 INCHES)
2 Sets Self-Adhesive Seals R0Y154
DOOR HARDWARE 08 71 00-28
HW-4K
1 Utility Lock F09
1 Armor Plate J101 x 1.275 MM (0.050 INCH) THICK NESS
1 Edge Guard (@ Wood Doors) J208M / J211 (VERIFY), CUT: HARDWARE
HW-4M
1 Classroom Hospital Lock F08 x PADDLES POINTING D OWN
1 Heavy-Duty Armor Plate J101 x 3.175 MM (0.125 IN CH) THICKNESS
1 Edge Guard (@ Wood Doors) J208M / J211 (VERIFY), CUT: HARDWARE
DOOR HARDWARE 08 71 00-29
HW-4P
1 Classroom Hospital Lock F08 x PADDLES POINTING D OWN
1 Armor Plate J101 x 1.275 MM (0.050 INCH) THICK NESS
1 Edge Guard (@ Wood Doors) J208M / J211 (VERIFY), CUT: HARDWARE
1 Overhead Stop C01541-ADJUSTABLE
1 Threshold J32300 x 57 MM WIDTH (2-1/4 INCHES)
1 Auto Door Bottom R0Y346 – HEAVY DUTY
2 Sets Self-Adhesive Seals R0Y154
HW-4Q
1 Pivot Set C07162 x 454KG (1000 LBS) WEIGHT CAP ACITY
1 Intermediate Pivot CO7311
1 Utility Hospital Lock F09 x LEAD-LINED x PADDLES POINTING DOWN
1 Armor Plate J101 x 1.275 MM (0.050 INCH) THICK NESS
2 Edge Guard (@ Wood Doors) J208M / J211 (VERIFY), CUT: HARDWARE
1 Overhead Stop C01541-ADJUSTABLE
1 Set Self-Adhesive Seal R0Y154
DOOR HARDWARE 08 71 00-30
HW-4U
1 Public Restroom Lock F09
1 Closer C02011/C02021
1 Closer CO2051/CO2061
1 Kick Plate J102
1 Mop Plate (@ Inswing Doors) J103
1 Floor Stop (@ Outswing Doors) L02121 x 3 FASTENER S
1 Wall Stop (@ Inswing Doors) L02101 CONVEX
1 Set Self-Adhesive Seals R0Y154
PROVIDE NON-HOLD-OPEN CLOSER AT TOILET ROOMS.
HW-5
1 Storeroom Lock F07
1 Closer C02011/C02021
1 Kick Plate J102 (@ STORAGE, EVM, & HAC ROOMS O NLY)
DOOR HARDWARE 08 71 00-31
HW-5B
1 Storeroom Lock F07
1 Closer C02011/C02021
1 Armor Plate J101 x 1.275 MM (0.050 INCH) THICK NESS
1 Edge Guard (@ Wood Doors) J208M / J211 (VERIFY), CUT: HARDWARE
1 Floor Stop L02121 x 3 FASTENERS
1 Set Self-Adhesive Seals R0Y154
HW-5D
1 Storeroom Lock F07
1 Kick Plate J102 (@ STORAGE, EVM, & HAC ROOMS O NLY)
1 Floor Stop (@ Inswing Doors) L02121 x 3 FASTENERS
1 Wall Stop (@ Outswing Doors) L02101 CONVEX
HW-5E
1 Storeroom Lock F13-MOD x RIGID OUTSIDE LEVER x KEY
RETRACTS DEADBOLT AND LATCHBOLT
1 Armor Plate J101 x 3.125 MM (0.125 INCH) THICK NESS
1 Edge Guard (@ Wood Doors) J208M / J211 (VERIFY), CUT: HARDWARE
DOOR HARDWARE 08 71 00-32
HW-5F
1 Storeroom Lock F07
1 Closer (@ Rated Doors) C02011/C02021
1 Heavy-Duty Armor Plate J101 x 3.175 MM (0.125 IN CH) THICKNESS
1 Edge Guard (@ Wood Doors) J208M / J211 (VERIFY), CUT: HARDWARE
HW-6
1 Exit Device TYPE 1 F13 LEVER
1 Key Cylinder TYPE AS REQUIRED
1 Closer C02011/C02021
1 Floor Stop L02121 x 3 FASTENERS
1 Set Self-Adhesive Seals R0Y154
HW-8D
Each [ADO] Aluminum Storefront Pair to Have: NON- RATED
2 Pivot Sets C07162
2 Intermediate Transfer Pivots C07321 x 4-WIRES
2 Intermediate Pivots C07321
2 Push/Pull Bar Sets J505 – 305 MM (12 INCH) CENTE R-TO-CENTER
PULL
2 Overhead Stops C01541-ADJUSTABLE
DOOR HARDWARE 08 71 00-33
HW-10H
Each [ADO] Lead-Lined Pair to Have: RATED/NON-R ATED
2 Bottom Pivots C07162 LESS TOP PIVOT x 454KG (10 00 LBS)
WEIGHT CAPACITY
1 Intermediate Pivot C07311 (MIDDLE OF ACTIVE LEAF )
1 Intermediate Transfer Pivot CO7311 x 4 WIRE TRANS FER (MIDDLE OF
INACTIVE LEAF)
2 Intermediate Transfer Pivot CO7311 x 4 WIRE TRANS FER (NEAR TOP OF
EACH LEAF)
1 Set Auto Flush Bolts TYPE 25 LESS BOTTOM BOLT X LEAD-LINED
1 Hospital Utility Lock F09 x PADDLES POINTING DOW N X LEAD-LINED
1 Electric Unlatch Strike E09321 (FAIL SECURE) (LE AD-LINED)
1 Power Supply REGULATED, FILTERED, 24VDC, AMPERA GE
AS REQUIRED
1 Coordinator TYPE 21A
1 Overlapping Astragal with R0Y634 x R0Y154 x THRU- BOLTS X LEAD-LINED
Self-Adhesive Seal
2 Armor Plates J101 x 1.275 MM (0.050 INCH) THICK NESS
4 Edge Guard (@ Wood Doors) J208M / J211 (VERIFY), CUT: HARDWARE
2 Overhead Stops C01541-ADJUSTABLE
1 Set Self-Adhesive Seals R0Y154
AUTOMATIC DOOR OPERATORS AND CONTROLS BY SECTION 08 71 13, AUTOMATIC DOOR
OPERATORS.
POWER TRANSFER PIVOTS NEAR TOP OF EACH DOOR FOR RE-ACTIVATION SENSOR
WIRING (RE-ACTIVATION SENSORS PROVIDED BY SECTION 0 8 71 13).
DOOR HARDWARE 08 71 00-34
INTERIOR SINGLE SECURITY DOORS
HW-SH-3C
Each [PB] Door to Have: NON-RATED/RATED
1 Push-button Combination Lock N3 – A156.13 F07 G1 E06
1 Closer C02011/C02021
1 Armor Plate J101 x 1.275 MM (0.050 INCH) THICK NESS
1 Edge Guard (@ Wood Doors) J208M / J211 (VERIFY), CUT: HARDWARE
HW-SH-3D
Each [AC, EL, REX, DPS] Door to Have: RATED
X ADJUSTA-SCREWS X 4-THRUWIRE
TRANSFER X IN-HINGE ACCESS PANEL
1 Electrified Lock F07 (E01-REX, E06) 24VDC
1 Power Supply REGULATED, FILTERED, 24VDC, AMPERA GE
AS REQUIRED
1 Closer C02011/C02021
1 Armor Plate J101 x 1.275 MM (0.050 INCH) THICK NESS
1 Edge Guard (@ Wood Doors) J208M / J211 (VERIFY), CUT: HARDWARE
1 Threshold J32300 x 57 MM WIDTH (2-1/4 INCHES)
1 Auto Door Bottom R0Y346 – HEAVY DUTY
2 Sets Self-Adhesive Seals R0Y154
1 Alarm Contact
120V…
This is the start of the file's text. The full file is on GovTribe.