36E77618B0087-0002001.pdf
PDF 805 KB Posted
- Solicitation number
- 36E77618B0087
About this file
36E77618B0087 0002 Sheet A142A - RFI Wall Type - Amendment.pdf
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36E77618B0087-0003000.docx | DOCX document | |
| 36E77618B0087-0004000.docx | DOCX document | |
| 36E77618B0087-0002002.pdf | ||
| 36E77618B0087-0002003.pdf | ||
| 36E77618B0087-0002000.docx | DOCX document | |
| 36E77618B0087-0001000.docx | DOCX document | |
| 36E77618B0087_1.docx | DOCX document | |
| Final_SCOPE_OF_WORK_501-330.doc | DOC document | |
| Specifications_-_Bldg_41-4A_20_Bed_Unit_Project_Manual_-_Issued_For_Bid_-_Volume_2.pdf | ||
| Wage_Determination_-_Building_-_New_Mexico.txt | TXT text file | |
| Zip_File_100__Drawings_Albuq_NM_02.zip | ZIP file | |
| Specification_-_Bldg_41-4A_20_Bed_Unit_Project_Manual_-_Issued_For_Bid_-_Volume_1.pdf |
Show all 12
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
C
12 13 14
E7
A343
E8
A343
B4
A240
A244
E3
A244E7
A244
E4
4A-107
PATIENT ROOM
4A-164
HALL
4A-106
PATIENT ROOM
4A-133A
TELECOM CLOSET
4A-133B
SIGNAL CLOSET
4A-133
HALL
4A-133C
ELECTRICAL CLOSET
4A-105
PATIENT ROOM
4A-104A
PATIENT BATHROOM
4A-105A
PATIENT BATHROOM
4A-104
PATIENT ROOM
4A-103
PATIENT ROOM
4A-102A
PATIENT BATHROOM
4A-103A
PATIENT BATHROOM
4A-160
CORRIDOR
4A-165
HALL
4A-140
WORKROOM TEAM
4A-139
CLEAN SUPPLY
4A-141
WORKROOM NURSE
4A-138
SOILED WORKROOM
4A-139
4A-103 4A-105
4A-133
4A-106
4A-106A
4A-103A
10 26 00.01
10 26 00.01
10 26 00.01
130.00° 130.00°
.0
ALIGN
ALIGN
10 26 00.01
A246
C1
A246
E4
2' - 7" 3' - 11" 13' - 4" 5' - 3" 7' - 0" 6' - 6" 9' - 0" 4' - 6"
4A-102A 4A-104A
4A-105A
3' - 5" 6' - 5" 8' - 5" 6' - 7 1/2" 7' - 6" 15' - 0" 4' - 2 3/8"
E3
A344
/8
/2
/8
/8
/8
S E
E G
E N
E R
A L N
O T E
B
R
' - 0
/8
/2
/8
P A
T
IE
N T
H E
A D
W A
L L
C E
N T
E R
L
IN
E
6' - 0 3/8" 15' - 3" 8' - 9 5/8"
11"
4A-138
09 22 16.13
A244
E1
A243 A7
A2
A4
A5
A AA A
C
A
E5
A343
09 22 16.36
09 22 16.36
09 22 16.36
4A-104
10 44 13.01
CRASH
CART
4A-107
22 13 20.02
ENCLOSED
VOID SPACE
09 22 16.12
09 22 16.12
09 22 16.12
09 22 16.12
09 22 16.11
09 22 16.12
09 22 16.11
09 22 16.12
09 22 16.12
09 22 16.11
09 22 16.11
10 44 13.01
4A-106A
PATIENT BATHROOM
09 22 16.36
6' - 1 1/2"
6' - 1 1/2"
/2
1' - 0"
/2
/2
R 4' - 11 1/2"
5' - 0" 6' - 8 1/2"
2' - 4"
1' - 0"
/2
2"
5' - 0 1/2"
ALIGN
4A-164B
LINEN STORAGE
4A-164B
A541
B5
TYPICAL
A541
B5
TYPICAL
A546
C8
SIM
B
A546
E6 Sim
A546
E6 Sim
A546
C8
SIM
F5
A243
KEY PLANREFERENCE KEYNOTESGENERAL NOTES
EXISTING TO REMAIN
SMOKE PARTITION, UNRATED: TYPE 1
HIGH STC PARTITION, TYPE 4
4" SHAFT WALL, 1 HOUR: TYPE 2
UNRATED ACOUSTIC PARTITION: TYPE 3
1 HOUR RATED PARTITION: TYPE 5
PARTITION LEGEND
CHASE/FURRING PARTITION: TYPE 6
A. DIMENSIONS TO LEFT OR BOTTOM FACE OF STUD OR GRIDLINE UNLESS NOTED
OTHERWISE
B. AT EGRESS PATH: FIELD VERIFY EXISTING CONDITIONS AND MAINTAIN MINIMUM
8' CLEAR BETWEEN CORRIDOR FINISHES
C. PATIENT ROOM MOCKUPS REQUIRED: CONTRACTOR TO CONSTRUCT TWO IN-
PLACE MOCKUPS OF A SINGLE PATIENT ROOM FOR REVIEW BY THE COR AND AE
TEAM.
• THE FIRST MOCKUP WILL BE OF THE HEADWALL TO FINALIZE SPECIFIC
CASEWORK AND MEP SYSTEM CONFIGURATION.
• THE SECOND MOCKUP WILL BE OF FINAL ROOM FINISHES TO FINALIZE
SPECIFIC MATERIAL TERMINATIONS AND DETAILS.
• THE THIRD MOCKUP WILL BE OF THE PATIENT ROOM LIFTS TO ENSURE
COORDINATION OF SYSTEM AND TRANSITION BETWEEN PATIENT ROOM AND
PATIENT BATHROOM.
OUTSIDE WORK AREA
IMPACT RESISTANT WALL
PROTECTION SHEET
SYMBOL LEGEND
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Dwg. ofRevisions: Date
CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1
B
A
C
D
E
F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
VA FORM 08-6231
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
NMVAHCS PLANNING AND ENGINEERING
NMVAHCS BLDG 41-
4A M/S 20 BED UNIT
501-330
41-A
D/P/S # 13-0044.001
C U s e rs \t y le ry \D o c u m e n ts
\1 -0
-A -B
U
IL
D O
U T
-v
T y le rY .r v t
/2
/2
:3
:3
A
M
LEVEL 4 ENLARGED FLOOR PLAN -
SECTOR 2
A142A
MP HA/MA
1501 San Pedro Dr SE Albuquerque, NM 87108
04-27-2018
ISSUED FOR BID
1/4" = 1'-0"E2 LEVEL 4 ENLARGED FLOOR PLAN - SECTOR 2
D A
BC
NORTH
09 22 16.11 2 1/2" STUD FURRING, TIGHT TO STRUCTURE, 5/8" GYPSUM BOARD ON
ROOM SIDE
09 22 16.12 3-5/8" METAL STUD FURRING, 5/8" GYPSUM BOARD ON ROOM SIDE
09 22 16.13 6" PARTITION
09 22 16.36 TYPICAL PATIENT ROOM WINDOW FURROUT: 3-5/8" WALL UP TO
WINDOW SILL, WITH SOLID SURFACE SILL.
10 26 00.01 HANDRAIL AND BUMPER RAIL WITH SHEET WALL PROTECTION
10 44 13.01 FIRE EXTINGUISHER CABINET
22 13 20.02 LINEAR SHOWER DRAIN - PROVIDE OFFSET TAILPIECE TO CLEAR BEAM
BELOW, AS REQUIRED
Bill Line
Bill Line
Bill Line
Bill Line
Bill Line
Bill Text Box
PLEASE CONFIRM THIS WALL TYPE IS CHASE/FURRING PARTITION TYPE 6
WITH DRYWALL ON ONLY 1 SIDE PER PARTITION TYPE DETAILS
File details come from the government source that posted it.