36C78627Q0014 Questions and Answers.docx
DOCX document 20 KB Posted
- Attached to
- Oily Water Waste Removal and Sand Interceptor Cleaning Services, Ft. Bliss National Cemetery
- Solicitation number
- 36C78627Q0014
About this file
This is a Questions and Answers document addressing clarifications for solicitation 36C78627Q0014, an RFQ for oily water waste removal and sand interceptor cleaning services at Ft. Bliss National Cemetery in El Paso, Texas.
The work scope involves removing approximately 375 gallons of non-hazardous oily water and sediment from a single-compartment 375-gallon oil/water separator tank and cleaning its sand interceptor four times annually on an as-needed, on-call basis rather than a fixed schedule. Service must be scheduled within 48 hours of notification, though completion is not required within that timeframe. The government will provide a water source (spigot) at the wash bay for cleaning and refilling the interceptor after service. The contractor must have minimum three years of experience in recycling and waste services, with this experience required of the prime contractor rather than a qualified subcontractor; subcontractors may be utilized subject to VA's limitations on subcontracting clause (VAAR 852.219-75). Access to the facility is limited to working hours Monday through Friday, 0730-1630, as the area is secured within the Front Maintenance Yard. The oily water is classified as non-hazardous in Texas but is heavily regulated; the prime contractor must be familiar with all applicable federal, state, and local laws. The contract award will be a firm, fixed-price definitive quantity contract (not an IDIQ), with the minimum/maximum guarantee language removed from the solicitation. The Option Year 4 CLINs will be renumbered from 4003/4004 to 4001/4002 for consistency with other contract periods.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36C78627Q0014 A00002.pdf | ||
| Price Schedule Ft Bliss Haz Waste.docx | DOCX document | |
| 36C78627Q0014 A00001.pdf | ||
| US Dept of Labor Wage Determination 2015-5229.txt | TXT text file | |
| Statement of Work Ft Bliss Haz Waste Treatment.docx | DOCX document | |
| Price Schedule Ft Bliss Haz Waste.docx | DOCX document |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
36C78627Q0014 Questions and Answers
| Q: | The SOW table under Section 2 lists only the 375-gallon oil/water separator tank. Can you confirm the size/capacity of the sand interceptor in gallons, and whether it is single or double compartment? |
| A: | Single compartment / 375 gallons |
| Q: | Task 2 calls for removal of approximately 300 gallons of oily water per service, while SOW 2.B.2 requires all liquid and solid material to be removed to the bottom and the chambers rinsed. What is the estimated total volume per service event (oily water, rinse water, and sand/sludge solids in gallons or pounds) to be transported and disposed? If available, please provide recent disposal manifests or weight/volume tickets from prior services. |
| A: | Single task 375 gallons - requires all liquid and solid material to be removed and the chambers rinsed. Information on recent disposal manifest is not available. The tank should never be filled to the max level before a service is required. |
| Q: | SOW Section 3 states that services will be on a fixed schedule, but also that the COR or Cemetery Staff will notify the Contractor by telephone when service is required, and SOW 10.a refers to unscheduled pickups within 48 hours. Are the four services per year performed on a fixed schedule or on call? |
| A: | The four services are “On Call” and is due dependent of the wash rack use. Usage varies and a set date can not be scheduled through out the year(s). |
| Q: | The notice anticipates a Firm-Fixed-Price Definitive Quantity contract, but also states a guaranteed minimum of $5,000, a maximum aggregate value of $75,000 over five one-year ordering periods, payment for actual services performed, and SOW 9.e says all quantities are estimated and not binding. Can you confirm whether the award will be a definitive quantity contract or an IDIQ contract? |
| A: | The min/max guarantee does not apply to this contract and will be removed from the RFQ description. The contract will be for a definitive firm, fixed-price contract not an IDIQ. |
| Q: | SOW 2.B.4 and 2.F require rinsing the chambers and refilling the interceptor/separator with fresh water after cleaning. Will the Government provide a water source (spigot or hydrant) at the maintenance building/wash bay, or must the contractor bring its own water? |
| A: | Government will provide a water source (spigot) at the wash bay |
| Q: | The Option Year 4 CLINs in the Price Schedule are numbered 4003 and 4004, while all other periods use x001 and x002. Should these be 4001 and 4002? |
| A: | Yes, they should be 4001 and 4002 and will be renumbered. |
| Q: | Experience Requirement: The PWS specifies a minimum of three years of experience in recycling and waste services. Can this requirement be satisfied through a qualified subcontractor with the necessary experience, licenses, and certifications? |
| A: | The prime contractor/offeror must have the necessary experience, licenses, and certifications. |
| Q: | Subcontracting: Would J&R Federal Solutions LLC be permitted to serve as the prime contractor while utilizing an experienced, licensed subcontractor to perform the onsite services, subject to the required government approvals? |
| A: | The prime contractor/offeror must have the necessary experience, licenses, and certifications. Subcontractors may be utilized provided compliance with VAAR clause 852.219-75 “VA Notice of Limitations on Subcontracting”. |
| Q: | Qualifications: Are there any additional prime contractor qualifications, limitations on subcontracting, or documentation requirements we should be aware of before submitting our quotation? |
| A: | All qualifications, limitations on subcontracting and documentation is outlined in the RFQ. |
| Q: | Can the four annual visits be scheduled in advance, or are they strictly as needed? |
| A: | Strictly as needed |
| Q: | Does the 48-hour response requirement mean service must be completed within that time frame? |
| A: | Within the 48 hours of notification the contractor must schedule the service. It does not need to be completed within 48 hours. |
| Q: | Are there any restricted access areas, security clearances, or confined space entry requirements? |
| A: | The area can only be accessed during working hours (0730-1630) Monday- Friday as it is secured and within the Front Maintenance Yard area. |
| Q: | Is the oily wastewater classified as hazardous or nonhazardous? Are waste profiles available? |
| A: | Oily water from an oil-water separator (OWS) is not automatically classified as a hazardous waste in Texas, though it is heavily regulated. The prime contractor must be familiar with all the federal, state and local laws. |
| Q: | What is the estimated sludge and sediment volume per service? |
| A: | Unknown |
| Q: | Is the separator directly accessible by vacuum truck? |
| A: | Yes – accessible by vacuum |
| Q: | Will water be available onsite for cleaning and refilling? |
| A: | Yes – water is available on site for cleaning and refilling |
| Q: | The notice title and NAICS code (562211) describe hazardous waste collection and disposal, but the Statement of Work and price schedule describe pumping about 300 gallons of oily water from the 375-gallon oil/water separator and cleaning its sand interceptor four times a year. Those are usually handled by different types of companies with different permits, so the answer affects who we team with and how we price it. Is the work only the separator pumping and sand interceptor cleaning in the SOW, and should the removed material be handled as hazardous waste or as non-hazardous oily water for recycling or disposal? |
| A: | Work involves removing 375 gallons of oily water and sediment from oil/water separator tank. Oily water from an oil-water separator (OWS) is not automatically classified as a hazardous waste in Texas, though it is heavily regulated. The prime contractor must be familiar with all the federal, state and local laws. In the past by the same company handled both services. |
| Q: | The notice title and NAICS (562211, Hazardous Waste Treatment and Disposal) describe hazardous waste collection and disposal, but Attachment A (Statement of Work, "Oily water Waste Removal Contract," Technical requirements Tasks 2 and 3) and Attachment C (CLINs 0001/0002) describe removing about 300 gallons of oily water from the 375-gallon oil/water separator and cleaning the sand interceptor four times per year. Can you confirm the scope is limited to the oil/water separator pumping and sand interceptor cleaning in the SOW, and whether the removed material is to be managed as hazardous waste or as non-hazardous oily water/used oil for recycling or disposal? |
| A: | Oily water from an oil-water separator (OWS) is not automatically classified as a hazardous waste in Texas, though it is heavily regulated. The prime contractor must be familiar with all the federal, state and local laws. Remove 375 gallons of non-hazardous oily water/and sediment (sand, dirt) and clean its sand interceptor |