15342-C-108 STORM UTILITY PLAN-2020.05.19.pdf
PDF 2 MB Posted
- Solicitation number
- 36C78620B0003
About this file
This document outlines a federal contract opportunity for the construction of Columbarium Plaza 2 at Leavenworth National Cemetery in Leavenworth, Kansas. The scope of work includes demolishing existing structures, site preparation, erosion control, excavation, backfilling, grading, constructing foundations and footings, installing 1,720 niches across four double-sided and two single-sided columbarium walls, as well as irrigation, landscaping, signage, storm drainage, utilities, road pavement, curbs and other tasks defined in the specifications and drawings. The National Cemetery Administration intends to issue an Invitation for Bid through solicitation number 36C78620B0003 to expand burial capacity and ensure continued options for the veteran population served by Leavenworth National Cemetery. The Department of Veterans Affairs National Cemetery Administration is the contracting agency.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36C78620B0003 0001.docx | DOCX document | |
| 36C78620B0003 0002.docx | DOCX document | |
| 36C78620B0003-002.pdf | ||
| 36C78620B0003-005.pdf | ||
| 36C78620B0003-004.pdf | ||
| 36C78620B0003-003.pdf | ||
| 36C78620B0003-006.pdf | ||
| 36C78620B0003-001.docx | DOCX document |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
L F
R
C
P
E
R
D
T
R
R
C
R
R
18 LF - 12" RCP
@ 1.00%
18 LF - 12" RCP
@ 1.00%
20 LF - 12" RCP
@ 0.50%
11 LF - 8" PVC
@ 1.74%
11 LF - 8" PVC
@ 1.00%
20 LF - 8" PVC
@ 1.00%
22 LF - 8" SOLID DT
@ 0.50%
21 LF - 8" SOLID DT
@ 0.50%
CB-213
RIM 787.53
I. 785.53(8" OUT SE)
CBMH-212
RIM 789.64
I. 787.76(12" IN SE)
I. 785.42(8" IN NW)
I. 785.68(8" IN SW)
I. 781.99(4" IN W)
I. 781.99(4" IN SW)
I. 781.32(12" OUT E)
I. 786.27(8" IN NE)
CB-214
RIM 788.47
I. 786.47(8" OUT SW)
CBMH-206
RIM 791.93
I. 780.62(24" OUT NW)
I. 780.82(12" IN W)
I. 783.59(4" IN NW)
I. 786.73(4" IN SW)
I. 781.25(12" IN S)
CBMH-205
RIM 792.66
I. 786.11(12" IN SW)
I. 786.10(12" OUT N)
I. 791.38(4" IN SE)
CBMH-203
RIM 794.96
I. 793.49(4" IN SW)
I. 786.98(12" OUT NE)
CBMH-211
RIM 790.97
I. 787.94(12" OUT NW)
I. 788.27(8" IN SW)
I. 784.50(4" IN SW)
I. 784.50(4" IN W)
22 LF - 8" SOLID DT
@ 0.50%
21 LF - 8" SOLID DT
@ 0.50%
CB-210
RIM 787.53
I. 782.10(8" OUT S)
CBMH-208
RIM 788.94
I. 781.99(4" IN E)
I. 781.32(12" OUT W)
I. 781.99(4" IN NE)
I. 783.64(12" IN SE)
I. 785.68(8" IN E)
I. 781.92(8" IN N)
CBMH-209
RIM 791.42
I. 781.23(12" IN E)
I. 781.22(12" OUT SW)
I. 786.22(4" IN S)
CBMH-202
RIM 791.26
I. 783.90(12" IN - NEW)
I. 787.10(12" IN - EX.)
I. 780.97(12" IN - NEW)
I. 780.77(24" OUT - NEW)
CBMH-201
RIM 793.56
I. 786.40(12" OUT W)
I. 792.44(4" IN NE)
I. 787.57(4" IN N)
CBMH-207
RIM 790.97
I. 783.83(12" OUT NW)
I. 788.27(8" IN E)
I. 784.49(4" IN E)
I. 784.46(4" IN NE)
EX. CBMH-104
RIM 783.90
NOTE: CORE DRILL 24" PIPE
OPENING & ADJUST CASTING
TO NEW RIM ELEVATION
I. 780.10(24" IN - NEW)
I. 774.80(60" IN - EX.)
I. 774.50(60" OUT - EX.)
EX. CBMH-103
RIM 787.56
NOTE: CORE DRILL 24"
PIPE OPENING, PATCH
PREVIOUS 12" OPENING
I. 780.30(24" IN - NEW)
I. 780.90(24" IN - EX.)
I. 779.70(60" IN - EX.)
I. 779.50(60" OUT - EX.)
CO-21
I. 794.72(4" OUT)
RIM 796.18
CO-24
I. 794.62(4" OUT)
RIM 796.08
CO-22
I. 788.00(4" OUT)
RIM 795.70
CO-25
I. 788.00(4" OUT)
RIM 795.64
CO-26
I. 793.42(4" OUT)
RIM 794.92
CO-28
I. 792.29(4" OUT)
RIM 793.79
CO-27
I. 877.00(4" OUT)
RIM 794.48
CO-29
I. 783.83(4" OUT)
RIM 788.94
CO-23
I. 787.20(4" OUT)
RIM 793.12
1 LF - 4" PERF DT
@ 340.47%
CBMH-204
I. 786.46(12" OUT)
I. 792.36(4" IN)
I. 787.72(4" IN)
I. 786.56(12" IN)
RIM 793.86
40 LF - 4" PERF. DT
@ 0.50%
40 LF - 4" PERF. DT
@ 0.50%
9 LF - 8" PERF. DT
@ 0.50%
13 LF - 8" PERF. DT
@ 0.50%
13 LF - 8" PERF. DT
@ 0.50%
6 LF - 4" SOLID DT
@ 43.36%
2 LF - 8" SOLID DT
@ 0.50%
8 LF - 4" SOLID DT
@ 31.39%
40 LF - 4" PERF. DT
@ 0.50%
40 LF - 4" PERF. DT
@ 0.50%
6 LF - 4" SOLID DT
@ 43.36%
2 LF - 8" SOLID DT
@ 0.50%
8 LF - 4" SOLID DT
@ 31.12%
13 LF - 8" PERF. DT
@ 0.50%
9 LF - 8" PERF. DT
@ 0.50%
13 LF - 8" PERF. DT
@ 0.50%
44 LF - 4" PERF. DT
@ 0.50%
44 LF - 4" PERF. DT
@ 0.50%
8 LF - 4" SOLID DT
@ 31.12%
2 LF - 8" SOLID DT
@ 0.50%
6 LF - 4" SOLID DT
@ 61.27%
40 LF - 4" PERF. DT
@ 0.50%
13 LF - 8" PERF. DT
@ 0.50%
9 LF - 8" PERF. DT
@ 0.50%
13 LF - 8" PERF. DT
@ 0.50%
40 LF - 4" PERF. DT
@ 0.50%
8 LF - 4" SOLID DT
@ 31.39%
2 LF - 8" SOLID DT
@ 0.50%
2 LF - 8" SOLID DT
@ 0.50%
6 LF - 4" SOLID DT
@ 43.36%
40 LF - 4" PERF. DT
@ 0.50%
13 LF - 8" PERF. DT
@ 0.50%
9 LF - 8" PERF. DT
@ 0.50%
13 LF - 8" PERF. DT
@ 0.50%
40 LF - 4" PERF. DT
@ 0.50%
1 LF - 4" PERF DT
@ 340.75%
2 LF - 8" SOLID DT
@ 0.50%
2 LF - 8" SOLID DT
@ 0.50%
8" INLET
RIM: 792.58
I: 788.47
8" INLET
RIM: 792.58
I: 788.51
8" INLET
RIM: 792.58
I: 788.58
8" INLET
RIM: 792.58
I: 788.40
8" INLET
RIM: 789.99
I: 785.81
8" INLET
RIM: 789.99
I: 785.88
8" INLET
RIM: 789.99
I: 785.92
8" INLET
RIM: 789.99
I: 785.99
8" INLET
RIM: 792.58
I: 788.51
8" INLET
RIM: 792.58
I: 788.47
8" INLET
RIM: 792.58
I: 788.40
8" INLET
RIM: 792.58
I: 788.58
8" INLET
RIM: 789.99
I: 785.99
8" INLET
RIM: 789.99
I: 785.92
8" INLET
RIM: 789.99
I: 785.88
8" INLET
RIM: 789.99
I: 785.81
2 LF - 8" SOLID DT
@ 0.50%
CO-18
I: 786.00
CO-14
I: 788.59
CO-13
I: 782.33
CO-17
I: 782.33
CO-20
I: 786.00
CO-19
I: 782.33
CO-16
I: 788.59
CO-15
I: 782.33
CO-9
I: 784.83
CO-10
I: 788.55
CO-5
I: 784.83
CO-6
I: 791.18
CO-1
I: 788.00
CO-2
I: 791.14
CO-4
I: 791.14
CO-3
I: 788.00
CO-8
I: 791.18
CO-7
I: 784.83
CO-12
I: 788.55
CO-11
I: 784.83
1 LF - 4" PERF DT
@ 340.47%
PROPOSED
STORM SEWER
STRUCTURE
SCHEDULE
NAME
CBMH-212
CBMH-211
CBMH-209
CBMH-208
CBMH-207
CBMH-206
CBMH-205
CBMH-204
CBMH-203
CBMH-202
CBMH-201
CB-214
CB-213
CB-210
SIZE
CASTING
R-2565
R-2565
R-2565
R-2565
R-2565
R-2565
R-2565
R-2565
R-2565
R-2565
R-2565
EJ 6106-N 1-1/2"
EJ 6106-N 1-1/2"
EJ 6106-N 1-1/2"
STRUCTURAL:
AST
7301 OHMS LANE
SUITE 215
EDINA, MN 55439
(952) 854-9302
JOHN LEVAR
IRRIGATION:
EC DESIGN
400 5TH STREET
WEST DES MOINES
IA 50265
(515) 225-6365
ERIK CHRISTIANSEN
COST ESTIMATING: GEOTECHNICAL:
TERRACON
15620 W 113th Street
LENEXA
KS 66219
(913) 998-7480
DAN BARNETT
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
Fil e P ath
BID DOCUMENTS
U.S. Department of Veterans Affairs
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseCONSULTANTS
321 5 6 7 8 9 10
Project Director
Revisions: Date:
o n e e i g h t h i n c o e f o t o n e q u a r t e r i n o t t h r e e e i g h t o t o n e h a l f i n o t t h r e e q u a r t e r s o t o n e i n o t o n e a d e h a l f i n o t t h r e e i n c h s o t
A
B
C
D
E
F
COLUMBARIUM PLAZA 2
150 MUNCIE ROAD
LEAVENWORTH, KANSAS 66048
897CM3022
JANUARY 9, 2020 OF 36
KEY MAP
BID DOCUMENTS
Office of Design and Construction
Services
StampARCHITECT/ENGINEER OF RECORD
1 3 6 0 5 1 s t A v e . N . # 1 0 0 P l y m o u t h , M N 5 5 4 4 1 P 7 6 3 . 4 1 2 . 4 0 0 0 | F 7 6 3 . 4 1 2 . 4 0 9 0 | a e - m n . c o m Anderson Engineering of Minnesota, LLC | Proj # 15342
CPMI
1001 GRAND AVE. #201
WEST DES MOINES
IA 50265
(515) 380-7370
BRYAN BERTRAND
1/9/2020
Y
V
A
N
A
A V
E N
W O
R T
H
N
C
C
O L U
M B
A R
I U
M
C i v i l
C
A l e s
S
H E
E T
S C
U
T I L I T
I E
S d w g
P
M
STORM UTILITY PLAN
C-108
14EB MM
N
0 10' 20'
SCALE:
STORM UTILITY PLAN
1" = 10' (30" x 42" PAPER SIZE)
LEGEND
GENERAL NOTES
1. INSTALL INLET PROTECTION
DOWNSTREAM OF CONSTRUCTION
2. INSTALL BIOROLL AT CONSTRUCTION
LIMITS
3. RESTORE DISTURBED AREA WITH 6"
TOPSOIL, SOD & IRRIGATION
EXISTING CONTOURS
EXISTING STORM SEWER
EXISTING STORM SEWER
INLET
UTILITY OFFSET
PROPOSED STORM
SEWER
PROPOSED SOLID WALL
PVC DRAINTILE
PROPOSED DRAINTILE
PROPOSED DRAINTILE
@ FOUNDATION, SEE
C-109
PROPOSED DRAINTILE
CLEANOUT
PROPOSED STORM
MANHOLE
INLET PROTECTION
N
0 5' 10'
SCALE:
STORM UTILITY PLAN - COLUMBARIUM COURT ENLARGEMENT
1" = 5' (30" x 42" PAPER SIZE)
C-108
FOUNDATION DRAINAGE
SEE C-109 FOR DETAILS
(TYP.)
1 REVISED FOUNDATION DRAIN ELEVATIONS 05/19/2020
AutoCAD SHX Text
BUILDING
AutoCAD SHX Text
RIM=786.2 SE INV=784.1
AutoCAD SHX Text
RIM=787.5 SE INV=782.7 NW INV=782.7 NE INV=782.7
AutoCAD SHX Text
RIM=791.3 NW INV=786.8 SE INV=787.1
AutoCAD SHX Text
60" CMP
AutoCAD SHX Text
12" PVC
AutoCAD SHX Text
12" PVC
AutoCAD SHX Text
12" RCP
AutoCAD SHX Text
12" RCP
AutoCAD SHX Text
12" PVC
AutoCAD SHX Text
15" CMP
AutoCAD SHX Text 26492
AutoCAD SHX Text
CO
| Sheets and Views |
| C-106 STORM UTILITY PLAN |
File details come from the government source that posted it. Updated .