About this file

36C78619R0063 J-1_Seed Project_Southeast District_788CM3919.pdf

View the file

Other files for this federal contract opportunity

Other files attached to National Cemetery Administration, multiple award task order contract (MATOC) for Southeast District, newest first.
File Type Posted
36C78619R0063-0001000.docx DOCX document
36C78619R0063-0001001.pdf PDF
36C78619R0063-0001002.xlsx XLSX spreadsheet
36C78619R0063-005.xlsx XLSX spreadsheet
36C78619R0063-004.pdf PDF
36C78619R0063-007.xlsx XLSX spreadsheet
36C78619R0063-001.docx DOCX document
36C78619R0063-006.xlsx XLSX spreadsheet
36C78619R0063-003.pdf PDF
36C78619R0063-000.docx DOCX document

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SCOPE OF WORK

IRRIGATION MAIN REPAIRS

NASHVILLE NATIONAL CEMETERY

NASHVILLE, TENNESSEE

Scope of Work:

1. Summary: A previous project completed a turf irrigation system for the entire cemetery. During construction of the Columbarium and Committal Shelter features, the 4” irrigation ring main was broken in Quad C, disabling the entire irrigation system in Quads C and D. This scope of work is to repair the mainline with an alternate routing behind the new columbarium to restore the original functionality of the irrigation main and affected irrigation zones in the vicinity of the new columbarium and committal shelter.

2. Attachments: As-Built drawings from contract VA786-12-C-0142, Irrigation System

3. Scope of Work: Work shall be proposed in a Base CLIN and 4 optional CLINs as follows.

Base CLIN 001: Irrigation Main Repair: Contractor shall provide all necessary supervision, labor, equipment, and materials to re-route and repair the 4” irrigation main in the vicinity of the new columbarium and committal shelter project while protecting and preventing damage to existing infrastructure. This work shall include (but is not limited to:

• Exploratory excavations as required to identify existing irrigation main, confirm irrigation main re-routing behind the new columbarium and committal shelter, and identify tie-in points required to repair irrigation main functionality.

• Installation of new 4” irrigation main segments to match existing. Conceptual routing is shown in Figure 1.

• Installation of control wires to match existing and restore original functionality.

• Location of buried gate valve in road (see as-builts) and restoring functionality and access point, or relocating gate value to a turf area to provide the same functionality and access as originally designed.

• Flushing of new irrigation main sections to remove any contamination or debris.

Figure 1: Base CLIN Conceptual Routing of new Irrigation Main segment

Optional CLIN 002: Assess/Restore Irrigation Zones adjacent to Columbarium/Committal Shelter

• Contractor shall provide all necessary supervision, labor, equipment, and materials to assess and repair as necessary of irrigation zone control valves and all associated laterals and sprinklers for zones 22, 23, 29, 30, 31, 32, 33, and 34.

• Removal of irrigation zone control valve 24 and capping the pipe to ensure no leakage while the rest of the system is in operation. This valve was previously designated for the area now occupied by the columbarium and committal shelter and shall be completely removed.

• Operational testing, from the controllers, of all remaining functional irrigation zones in Quads C and D to confirm control wires have been properly restored and irrigation system functions as originally designed and constructed.

Optional CLIN 003: Assess/Restore Irrigation Zones in vicinity of the lodge

• Contractor shall provide all necessary supervision, labor, equipment, and materials to assess and repair as necessary of irrigation zone control valves and all associated laterals and sprinklers for zones 18, 19, 20, 21, 10, 11, 12, and 13 to ensure they will function as per the original design.

• Operational testing and Distribution Uniformity Testing of all restored/repaired irrigation zones in this CLIN.

Optional CLIN 004: Redesign and Restore Irrigation Zone in vicinity of the former administrative building

• Contractor shall provide all necessary supervision, labor, equipment, and materials to redesign and/or repair as necessary of irrigation zone control valves and all associated laterals and sprinklers for Zone 8 to convert this zone to irrigate turfgrasses now in the place of the demolished former administrative office.

• Operational testing and Distribution Uniformity Testing of all restored/repaired irrigation zones in this CLIN.

Optional CLIN 005: Design and Install Irrigation Zone(s) in vicinity of the new columbarium and committal shelter

• Contractor shall provide all necessary supervision, labor, equipment, and materials to design and install new irrigation zones and all associated laterals and sprinklers for the new columbarium and committal shelter area to fully support all installed plants and grasses.

• Operational and Distribution Uniformity Testing of all restored/repaired irrigation zones in this CLIN.

• New Irrigation zone(s) shall be uniquely numbered and labelled with decoders, valve boxes, valve labelling, valve box lid branding to match existing.

4. General Requirements:

• Utility Location: Prior to commencing any excavation operations, the Contractor shall confirm the location of any utilities in the work area. Utilities include potable water systems, electrical power, gas, and water and sewer lines. A utility locator company may be brought in to assist in this process at the sole expense of the Contractor.

• Contractor Equipment: The Contractor shall not operate trucks, tractors, and other heavy equipment in excess of five tons on any turf area except when authorized in writing by the COR.

• Erosion Control: Contractor shall install and maintain erosion control material/methods to meet local requirements. Copies of these requirements may be reviewed by contacting the COR.

• Warning Signs: The Contractor shall provide adequate warning devices, signage, barricades, guards, flagmen or other necessary precautions, as determined by the COR(s) for the protection, safety, and warning to all pedestrians and vehicular traffic within the construction area.

• Qualifications: Irrigation Contractor must have demonstrated, using persons directly employed by the Contractor, experience with the installation of at least five irrigation systems having large diameter HDPE pipe (3-inch and larger) utilizing directional boring equipment, electro weld fittings and butt fusion fittings and joints.

5. Submittals:

• Provide irrigation information with table of contents and index sheet. Provide all required valves, sprinklers, pipe, ID tags, wire connectors, and fittings required to complete the work.

• Highlight items being supplied on the catalog cut sheets.

• Testing: Submit proof of testing report following completion of each test listed in Paragraph 6 this

Scope of Work. Unless otherwise noted, include name of test, date of test, name of the individual completing the test, name of the company completing the test and a summary of the test results. If repaired system fails test, document any and all retests until system passes test.

• Record Drawings: Submit information listed in Paragraph 12 of this Scope of Work.

6. Testing:

• Notify the COR five (5) working days in advance of any irrigation system testing.

• Pipelines jointed with solvent-welded PVC joints will be allowed to cure at least 24 hours before testing.

• Subsections of mainline and sub-mainline pipe may be tested independently, subject to the review of the COR.

• Furnish clean, clear water, pumps, labor, fittings and equipment necessary to conduct tests or retest.

For mainline repairs:

o Hydrostatic pressure testing of HDPE pipe must be conducted in accordance with ASTM F2164, Field Leak Testing of Polyethylene Pressure Piping Systems Using Hydrostatic Pressure. Fill HDPE pipe with water, raise to test pressure and allow to stabilize. Test pressure must be 1.5 times the operating pressure at the lowest point in the system. In accordance with ASTM F2164 section 9.8, pipe will pass test if the final pressure is within 5% of the test pressure for I hour. For safety reasons, hydrostatic testing only will be used.

o Purge air from pipe before test. Attach pressure gauge to a sprinkler riser in the middle of the sub-mainline pipe.

For any specified sprinkler zones requiring repairs per the SOW:

o Cap all sprinkler risers and conduct Hydrostatic Pressure Test for Solvent Weld Lateral Pipe.

o Subject pipe to a hydrostatic pressure equal to the anticipated operating pressure of 90 PSI for

30 minutes.

o Backfill any excavations to prevent pipe from moving under pressure.

o Purge air from pipe before test. Attach pressure gauge to a riser in the middle of the lateral.

o Pressurize the lateral via the remote-control valve then tum down flow control handle on remote control valve to seal off lateral.

o Observe pressure loss on pressure gauge. If pressure loss is greater than 5 PSI, identify reason for pressure loss. Replace defective pipe, fitting, joint, valve or appurtenance. Repeat test until pressure loss is equal to or less than 5 PSI.

o Cement or caulking to seal leaks is prohibited.

o After lateral passes test and prior to operational test, install sprinklers and backfill and compact all pipes, fittings, joints or appurtenance.

Operational Test-Valve-in-head sprinkler; Remote control valves, lateral piping and sprinklers for any specified sprinkler zones requiring repairs per the SOW o Activate each valve-in-head sprinkler and remote-control valve in sequence from each controller. Manual operation of the sprinklers or valves is not an acceptable method of activation. The COR will visually observe operation, water application patterns and leakage.

o Replace defective remote-control valve, solenoid, wiring or appurtenance to correct operational deficiencies.

o Replace, adjust, add or move water emission devices to correct operational or coverage deficiencies.

o Replace defective pipe, fitting, joint, valve, sprinkler or appurtenance to correct leakage problems. Cement or caulking to seal leaks is prohibited.

o Repeat test(s) until each lateral pass all test. Repeat tests, replace components and correct deficiencies at no additional cost to the Government.

7. Sleeving:

• Provide sleeve beneath hardscape for PVC irrigation pipe and wiring that cannot be horizontally bored. Provide separate sleeve beneath hardscape for wiring.

• Use high density, extra high molecular weight polyethylene pipe (HDPE), extruded from material meeting the specifications of cell classification on PE345434C, ASTM standard D3350, SDR I l, rated at 160 PSI conforming to the dimensions and tolerances established by ASTM F 714 for mainline pipe.

• Pipe sleeve sizes to be twice the diameter of the pipe routed through the sleeve. Wiring bundle contained in the sleeve should not exceed 40% of the available area within the sleeve per NEC recommendations.

8. Pipe and Fittings:

HDPE Mainline and Sub-mainline Pipe and Fittings:

o Use high density, extra high molecular weight polyethylene pipe (HDPE), extruded from material meeting the specifications of cell classification on PE 345434C, ASTM standard D3350, SDR I l, rated at I 60 PSI conforming to the dimensions and tolerances established by ASTM F 714 for mainline pipe.

o Join pipe lengths using butt-fusion technique as recommended by pipe manufacturer.

o Join HDPE to PVC pipe materials using HDPE (butt-fusion) x adapter with ductile iron back-up ring.

Lateral Pipe and Fittings (only as required to repair specified zones per the SOW):

o Use rigid, un-plasticized polyvinyl chloride (PVC) I 120, 1220 National Sanitation Foundation (NSF) approved pipe, extruded from material meeting the requirements of Cell Classification 12454-A or 12454-8, ASTM Standard D1784, with an integral belled end suitable for solvent Welding.

o Use Class 160, SDR-26, rated at 160 PSI, conforming to dimensions and tolerances established by ASTM Standard D2241 . Use PVC pipe rated at higher pressures than Class 160 in the case of small nominal diameters not manufactured in Class 160.

o Use solvent weld pipe for lateral pipe. Use Schedule 40, Type l, PVC solvent weld fittings conforming to ASTM Standards D2466 andDl784 for PVC pipe.

o Use primer approved by pipe manufacturer. Solvent cement to conform to ASTM Standard D2564, of type approved by pipe manufacturer.

9. Thrust Blocks

• Use thrust blocks for fittings on rubber gasketed pipe or transitions from HDPE pipe to PVC pipe. Use of mechanical restraints does not eliminate the need for installation of thrust blocks.

• Use 3,000-PSI concrete.

• Use 2-mil plastic.

• Use No. 4 Rebar wrapped or painted with asphalt tar-based mastic coating.

10. Controller Wire

• Control Wire: Use American Wire Gauge (AWG) #14 two-wire cable between control unit and decoder as recommended by control system manufacturer.

• Color: Wire color must be continuous over its entire length.

• Splices: Use 3M DBR/Y splices as recommended by control system manufacturer

• Valve Box: Use plastic (ABS) standard rectangular valve with black lid. Acceptable manufacturer is

Carson, Pentek, Rain Bird or approved equal.

• Warning tape: inert plastic film highly resistant to alkalis, acids, or other destructive chemical components likely to be encountered in soils. Three inches wide colored red and imprinted with "CAUTION: BURIED ELECTRIC LINE BELOW', in black lettering.

11. Other Components (only as required):

• Isolation Gate Valve Assembly: Match existing only as required to repair to original functionality.

• Remote Control Valve Assembly: Match existing only as required to repair specified irrigation zones if remote control valve is unserviceable.

• Pop-Up Rotor or Spray Sprinkler Assemblies: Match existing only as required to repair to original functionality. If original sprinkler assembly cannot be found, match adjacent existing and select the appropriate nozzle for the required throw distance and coverage area.

• All new or repaired irrigation zones will be installed with decoders to match existing, valve boxes to match existing, with valve box lid labelling and valve tags to match existing.

12. Record Drawings:

• The Contractor is responsible for documenting all repairs to the system and all changes to the as-built drawings provided from the previous project.

• Record irrigation components, pipe and wiring network alterations. Record Work that is installed differently than shown on the As-Built Documents. Special attention must be given to pipe routing and controller stations.

• At completion of repairs, Contractor must hire a Professional Licensed Surveyor to survey/document locations of all sprinklers, irrigation components enclosed within a valve box, controllers, flower water stations, wire splice boxes and "coordination points" that have been relocated from the provided as-built drawings. If necessary, Contractor must flag sprinklers for Surveyor. Surveyor must use "SPR" as attribute data for sprinklers, the branding in the valve box lid (for example "GV", 'AV", "QC') as the attribute data for components enclosed within a valve box, "CTLR" as the attribute data for controllers, "FWS" for flower water station, "WS" for wire splice boxes and "CP" for coordination points. COR will provide AutoCAD file for Surveyor showing coordination points to produce "Survey Drawing". Surveyor is to use the AutoCAD files to develop and provide an AutoCAD file of the Survey Drawing

• Prior to project completion, Contractor must provide the project redline drawings and the Survey Drawing" AutoCAD files to COR.

C D

QUAD_C

25262728

FS

FS

QUAD_D

N: 695948.67

E: 1753981.61

Z: 513.72

N:695292.22

E: 1754078.62

Z: 487.74

PARKING LOT

N:695776.46

E:1754577.90

Z:491.62

N:695432.73

E:1754450.77

Z:478.33

MATCH-LINE

M

A

T

C

H

L

I N

E

IR-1

IR-2

I R

I R

I R

M

A

T

C

H

L

I N

E

I R

I R

QUAD_C

QUAD_C

QUAD_C

QUAD_C

QUAD_D

QUAD_B

QUAD_A

1.

2.

3.

4.

5.

6.

0'

SCALE 1" = 30'

15' 30' 60'

SYMBOL MANUFACTURER/MODEL

HUNTER PROS-06 SPRAY HEAD 15` RADIUS

SYMBOL MANUFACTURER/MODEL

HUNTER I-20-04 ROTOR PART CIRCLE

HUNTER I-25-04 ROTOR PART CIRCLE

HUNTER I-25-04 ROTOR FULL CIRCLE

SYMBOL MANUFACTURER/MODEL

HUNTER ICV-G

QUICK COUPLER VALVE

FLORAL WATERING STATION

ISOLATION GATE VALVE (MAINLINE SIZE)

MASTER VALVE

AIR RELIEF VALVE

HUNTER ACC-99D CONTROLLER

HUNTER ACC-99D CONTROLLER

HUNTER ACC-99D CONTROLLER

HUNTER ACC-99D CONTROLLER

WEATHER STATION

FLOW SENSOR

IRRIGATION LATERAL LINE: PVC CLASS 200 SDR 21

IRRIGATION MAINLINE: HDPE

PIPE SLEEVE: HDPE

A

B

C

D

FS

IRRIGATION SCHEDULE

Nick Oval

Nick Oval

Nick Typewriter Existing valve has been paved over. Locate value, assess servicability, and install access point

Nick Oval

Nick Typewriter Control boxes are missing

Nick Typewriter Perform exploratory excavation to identify undamaged irrigation main tie-in location

Nick Arrow

Nick Line

Nick Line

Nick Line

Nick Typewriter Perform exploratory excavation to identify undamaged irrigation main tie-in location

Nick Oval

Nick Typewriter Routing is conceptual. Contractor to perform exploratory excavation as required to avoid existing utilities and adjust irrigation main routing to avoid existing utilities or other obstructions.

Nick Arrow

Nick Arrow

Nick Typewriter Base CLIN 001: Irrigation Main Repair

Nick Typewriter Optional CLIN 002: Assess/Restore Irrigation Zones adjacent to Columbarium/Committal Shelter

Nick Oval

Nick Typewriter Remove and Cap Line

Nick Arrow

Nick Typewriter Repair Irrigation Zone

Nick Oval

Nick Oval

Nick Oval

Nick Oval

Nick Oval

Nick Oval

Nick Oval

Nick Oval

Nick Typewriter Optional CLIN 003: Assess/Restore Irrigation Zones in vicinity of the lodge

Nick Oval

Nick Typewriter Repair Irrigation Zone

Nick Oval

Nick Oval

Nick Oval

Nick Oval

Nick Oval

Nick Oval

Nick Oval

Nick Oval

Nick Typewriter Redesign/Restore Irrigation Zone

Nick Oval

Nick Typewriter Optional CLIN 004: Redesign and Restore Irrigation Zone in vicinity of the former administrative building

Nick Oval

Nick Typewriter Redesign/Restore Irrigation Zone

Nick Oval

Nick Typewriter Optional CLIN 005: Design and Install Irrigation Zone(s) in vicinity of the new columbarium and committal shelter

Nick Cloud

Nick Typewriter New Irrigated Area

Nick Cloud

"General Decision Number: TN20190083 06/14/2019

Superseded General Decision Number: TN20180084

State: Tennessee

Construction Type: Building

County: Davidson County in Tennessee.

BUILDING CONSTRUCTION PROJECTS (does not include single family homes or apartments up to and including 4 stories).

Note: Under Executive Order (EO) 13658, an hourly minimum wage of $10.60 for calendar year 2019 applies to all contracts subject to the Davis-Bacon Act for which the contract is awarded (and any solicitation was issued) on or after January 1, 2015. If this contract is covered by the EO, the contractor must pay all workers in any classification listed on this wage determination at least $10.60 per hour (or the applicable wage rate listed on this wage determination, if it is higher) for all hours spent performing on the contract in calendar year 2019. If this contract is covered by the EO and a classification considered necessary for performance of work on the contract does not appear on this wage determination, the contractor must pay workers in that classification at least the wage rate determined through the conformance process set forth in 29 CFR 5.5(a)(1)(ii) (or the EO minimum wage rate,if it is higher than the conformed wage rate). The EO minimum wage rate will be adjusted annually. Please note that this EO applies to the above-mentioned types of contracts entered into by the federal government that are subject to the Davis-Bacon Act itself, but it does not apply to contracts subject only to the

Page 1 of 9beta.SAM.gov

7/8/2019https://beta.sam.gov/wage-determination/TN20190083/2/document

Davis-Bacon Related Acts, including those set forth at 29 CFR 5.1(a)(2)-(60). Additional information on contractor requirements and worker protections under the EO is available at www.dol.gov/whd/govcontracts.

Modification Number Publication Date 0 01/04/2019 1 05/03/2019 2 06/14/2019

BOIL0455-001 03/01/2018

Rates Fringes

Boilermaker....................$ 30.07 21.61

BRTN0005-009 05/01/2019

Rates Fringes

BRICKLAYER.......................$ 26.62 2.40

CARP0223-002 04/24/2016

Rates Fringes

CARPENTER (Cabinet Installation and Scaffold Builder Only)....................$ 23.95 11.36

* ELEC0429-005 06/01/2019

Rates Fringes

ELECTRICIAN......................$ 27.24 13.21

Page 2 of 9beta.SAM.gov

ENGI0369-007 05/01/2013

Rates Fringes

OPERATOR: Forklift..............$ 24.47 10.85

IRON0492-008 05/01/2018

Rates Fringes

IRONWORKER, STRUCTURAL AND

REINFORCING......................$ 26.11 14.02

PLUM0572-006 05/01/2018

Rates Fringes

PIPEFITTER, Includes HVAC Pipe Installation................$ 35.60 17.37

SHEE0177-004 05/01/2017

Rates Fringes

SHEET METAL WORKER, Includes HVAC Duct and Metal Roof Installation.....................$ 26.71 13.32

SUTN2009-082 09/21/2009

Rates Fringes

CARPENTER, Includes Drywall Hanging, and Form Work (Excludes Cabinet Installation, and Scaffold Building)........................$ 17.83 3.69

Page 3 of 9beta.SAM.gov

CEMENT MASON/CONCRETE FINISHER...$ 17.68 0.00

LABORER: Asphalt Raker..........$ 12.85 0.00

LABORER: Common or General......$ 12.41 1.04

LABORER: Landscape..............$ 9.60 0.80

LABORER: Mason Tender - Brick...$ 13.51 0.00

LABORER: Roof Tearoff...........$ 9.75 0.49

OPERATOR:

Backhoe/Excavator/Trackhoe.......$ 16.27 0.00

OPERATOR: Bobcat/Skid Steer/Skid Loader................$ 17.68 0.00

OPERATOR: Bulldozer.............$ 15.47 3.33

OPERATOR: Crane.................$ 19.16 3.35

OPERATOR: Mechanic..............$ 18.66 3.39

OPERATOR: Paver (Asphalt, Aggregate, and Concrete).........$ 14.25 0.00

OPERATOR: Roller................$ 12.83 0.00

PAINTER: Brush, Roller and Spray............................$ 13.15 0.00

PLUMBER, Excludes HVAC Pipe Installation.....................$ 20.03 9.00

ROOFER: Built up Roof...........$ 12.74 0.00

Page 4 of 9beta.SAM.gov

ROOFER: Rubber Roof.............$ 16.82 4.77

ROOFER: Single Ply Roof.........$ 16.50 0.32

TILE FINISHER....................$ 10.00 0.74

TRUCK DRIVER: Dump Truck........$ 12.16 0.00

TRUCK DRIVER: Material Truck....$ 12.16 1.66

TRUCK DRIVER: Pickup Truck......$ 11.70 3.92

WELDERS - Receive rate prescribed for craft performing operation to which welding is incidental.

Note: Executive Order (EO) 13706, Establishing Paid Sick Leave for Federal Contractors applies to all contracts subject to the Davis-Bacon Act for which the contract is awarded (and any solicitation was issued) on or after January 1, 2017. If this contract is covered by the EO, the contractor must provide employees with 1 hour of paid sick leave for every 30 hours they work, up to 56 hours of paid sick leave each year.

Employees must be permitted to use paid sick leave for their own illness, injury or other health-related needs, including preventive care; to assist a family member (or person who is like family to the employee) who is ill, injured, or has other health-related needs, including preventive care; or for reasons resulting from, or to assist a family member (or person who is like family to the employee) who is a victim of, domestic violence, sexual assault, or stalking. Additional information on contractor requirements and worker protections under the EO is available at www.dol.gov/whd/govcontracts.

Page 5 of 9beta.SAM.gov

Unlisted classifications needed for work not included within the scope of the classifications listed may be added after award only as provided in the labor standards contract clauses (29CFR 5.5 (a) (1) (ii)).

The body of each wage determination lists the classification and wage rates that have been found to be prevailing for the cited type(s) of construction in the area covered by the wage determination. The classifications are listed in alphabetical order of ""identifiers"" that indicate whether the particular rate is a union rate (current union negotiated rate for local), a survey rate (weighted average rate) or a union average rate (weighted union average rate).

Union Rate Identifiers

A four letter classification abbreviation identifier enclosed in dotted lines beginning with characters other than ""SU"" or ""UAVG"" denotes that the union classification and rate were prevailing for that classification in the survey. Example:

PLUM0198-005 07/01/2014. PLUM is an abbreviation identifier of the union which prevailed in the survey for this classification, which in this example would be Plumbers. 0198 indicates the local union number or district council number where applicable, i.e., Plumbers Local 0198. The next number, 005 in the example, is an internal number used in processing the wage determination. 07/01/2014 is the effective date of the most current negotiated rate, which in this example is July 1, 2014.

Union prevailing wage rates are updated to reflect all rate changes in the collective bargaining agreement (CBA) governing this classification and rate.

Page 6 of 9beta.SAM.gov

Survey Rate Identifiers

Classifications listed under the ""SU"" identifier indicate that no one rate prevailed for this classification in the survey and the published rate is derived by computing a weighted average rate based on all the rates reported in the survey for that classification. As this weighted average rate includes all rates reported in the survey, it may include both union and non-union rates. Example: SULA2012-007 5/13/2014. SU indicates the rates are survey rates based on a weighted average calculation of rates and are not majority rates. LA indicates the State of Louisiana. 2012 is the year of survey on which these classifications and rates are based. The next number, 007 in the example, is an internal number used in producing the wage determination. 5/13/2014 indicates the survey completion date for the classifications and rates under that identifier.

Survey wage rates are not updated and remain in effect until a new survey is conducted.

Union Average Rate Identifiers

Classification(s) listed under the UAVG identifier indicate that no single majority rate prevailed for those classifications; however, 100% of the data reported for the classifications was union data. EXAMPLE: UAVG-OH-0010 08/29/2014. UAVG indicates that the rate is a weighted union average rate. OH indicates the state. The next number, 0010 in the example, is an internal number used in producing the wage determination. 08/29/2014 indicates the survey completion date for the classifications and rates under that identifier.

A UAVG rate will be updated once a year, usually in January of each year, to reflect a weighted average of the current negotiated/CBA rate of the union locals from which the rate is based.

Page 7 of 9beta.SAM.gov

WAGE DETERMINATION APPEALS PROCESS

1.) Has there been an initial decision in the matter? This can be:

* an existing published wage determination

* a survey underlying a wage determination

* a Wage and Hour Division letter setting forth a position on a wage determination matter

* a conformance (additional classification and rate) ruling

On survey related matters, initial contact, including requests for summaries of surveys, should be with the Wage and Hour Regional Office for the area in which the survey was conducted because those Regional Offices have responsibility for the Davis-Bacon survey program. If the response from this initial contact is not satisfactory, then the process described in 2.)

and 3.) should be followed.

With regard to any other matter not yet ripe for the formal process described here, initial contact should be with the Branch of Construction Wage Determinations. Write to:

Branch of Construction Wage Determinations Wage and Hour Division U.S. Department of Labor 200 Constitution Avenue, N.W.

Washington, DC 20210

2.) If the answer to the question in 1.) is yes, then an interested party (those affected by the action) can request review and reconsideration from the Wage and Hour Administrator

Page 8 of 9beta.SAM.gov

(See 29 CFR Part 1.8 and 29 CFR Part 7). Write to:

Wage and Hour Administrator U.S. Department of Labor 200 Constitution Avenue, N.W.

Washington, DC 20210

The request should be accompanied by a full statement of the interested party's position and by any information (wage payment data, project description, area practice material, etc.) that the requestor considers relevant to the issue.

3.) If the decision of the Administrator is not favorable, an interested party may appeal directly to the Administrative Review Board (formerly the Wage Appeals Board). Write to:

Administrative Review Board U.S. Department of Labor 200 Constitution Avenue, N.W.

Washington, DC 20210

4.) All decisions by the Administrative Review Board are final.

END OF GENERAL DECISION"

Page 9 of 9beta.SAM.gov

P01_1-SOW_Nashville Irrigation Main Repairs
P01_2-Drawing_Nashville Irrigation Main Repairs
P07_WD BUILDING_Davidson County_Nashville Irrigation Main Repairs