36C78619B0014-0001004.pdf
PDF 16 MB Posted
- Attached to
- Grave Expansion- Roseburg Nat'l Cemetery
- Solicitation number
- 36C78619B0014
About this file
36C78619B0014 0001 190530 Roseburg 902-008 Bid Drawings - 4of5.pdf
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36C78619C0142-000.docx | DOCX document | |
| 36C78619B0014-0003000.docx | DOCX document | |
| 36C78619B0014-0002001.pdf | ||
| 36C78619B0014-0002000.docx | DOCX document | |
| 36C78619B0014-0001000.docx | DOCX document | |
| 36C78619B0014-0001003.pdf | ||
| 36C78619B0014-0001001.pdf | ||
| 36C78619B0014-0001002.pdf | ||
| 36C78619B0014-0001005.partial | — | |
| 36C78619B0014-007.pdf | ||
| 36C78619B0014-010.pdf | ||
| 36C78619B0014-009.xlsx | XLSX spreadsheet | |
| 36C78619B0014-006.docx | DOCX document | |
| 36C78619B0014-008.docx | DOCX document | |
| 36C78619B0014-001.docx | DOCX document | |
| 36C78619B0014-000.docx | DOCX document | |
| 36C78619B0014-000.docx | DOCX document |
Show all 17
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
S
R
PUMP HOUSE
3'-3
7'-
PUMP HOUSE
3'-3
7'-
LEGEND
PROPERTY LIMITS
CONSTRUCTION LIMITS
EXISTING MINOR CONTOUR
EXISTING MAJOR CONTOUR
PROPOSED MINOR CONTOUR
PROPOSED MAJOR CONTOUR
ADJACENT PROPERTY
BUILDING SETBACKS
PROPOSED STORM SEWER
PROPOSED DRAINTILE
OR ADVANEDGE
PROPOSED DRAINTILE
CLEANOUT
PROPOSED STORM MANHOLE
PROPOSED ACCESS DRIVE
EXISTING DECIDUOUS
TREES
EXISTING CONIFEROUS
TREES
INLET PROTECTION
CG-501
CG-501
CG-501
CG-501
Structural Engineering, Electrical Engineering:
AST
7301 Ohms Lane Edina, MN 55439
(952) 854-9302 John Levar
Irrigation:
Aqua Engineering 375 E. Horsetooth R Bldg. 2-202 Fort Collins, CO 80525
(907) 372-6104 Robert Beccard
Cost Estimating:
CPMI
3265 Northwood Circle Suite 170 Eagan, MN 55121
(952) 854-3663 Bryan Bertrand
Geotechnical Engineering:
Applied Geotechnical Engineering & Geologic Consulting 1314-B Center Drive #452 Medford, OR 97501
(541) 226-6658 Robin Warren
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
Fil e P ath
BID DOCUMENTS
U.S. Department of Veterans Affairs
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORDCONSULTANTS
321 4 5 6 7 8 9 10
Project Director
Revisions: Date:
o n e e i g h t h i n c o e f o t o n e q u a r t e r i n o t t h r e e e i g h o t o n e h a l f i n o t t h r e e q u a r t e r s o t o n e i n o t o n e a d e h a l f i n o t t h r e e i n c h o t
A
B
C
D
E
F
1 3 6 0 5 1 s t A v e . N # 1 0 0 P l y m o u t h , M i n n e s o t a 5 5 4 4 1 P 763.412.4000 F 763.412 4090 ae-mn.com
ROSEBURG NATIONAL CEMETERY
GRAVESITE EXPANSION
ROSEBURG, OREGON
902CM3008
MAY 9, 2019 OF 59
#15135
BID DOCUMENTS
Office of Design and Construction
Services
R
E
G
I
S
T
E
R
E
D
PR
O
F
E
S
S
I
O
N
A
L
E
N
G
I N
E
E
R
83168
OREGON
G
A
R
Y
R
. J
O
H
N
S
O
N
J
U
L
Y
EXP. JUNE 30, 2019
Stamp y v a n c a r o s e b u r g n a t c e m e t e r y g r a v e s i t e e x p a n s i o n c i v i l c a d f i l e s
S
H E
E T
S C
G
R A
D I N
G d w g
P
M
N
0 60' 120'
SCALE:
GRADING OVERALL
1" = 60' (30" x 42" PAPER SIZE)
CG-102
CG-103
CG-104
CG-105
CG-106
CG-108
CG-109
CG-107
GENERAL NOTES
1. ALL NEW STORM CATCH BASINS TO BE 48"
ROUND WITH A CASTING R-2595 CASTING
GRATE A FROM THE NEENAH FOUNDARY
CATALOG OR APPROVED EQUAL PER
DETAIL 1 & 2 OF SHEET CG-501.
GRADING OVERALL
CG-101
28GJ BF
AutoCAD SHX Text
14" PRESSURE PIPE
AutoCAD SHX Text
POSSIBLE EASEMENT PER VA PROVIDED RECORD PLANS
AutoCAD SHX Text
14" PRESSURE PIPE
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
CO
AutoCAD SHX Text
CO
AutoCAD SHX Text
CO
AutoCAD SHX Text
CO
AutoCAD SHX Text
CO
AutoCAD SHX Text
CO
AutoCAD SHX Text
CO
AutoCAD SHX Text
CO
AutoCAD SHX Text
CO
AutoCAD SHX Text
CO
AutoCAD SHX Text
CO
AutoCAD SHX Text
CO
AutoCAD SHX Text
CO
AutoCAD SHX Text
CO
AutoCAD SHX Text
CO
AutoCAD SHX Text
CO
AutoCAD SHX Text
CO
AutoCAD SHX Text
CO
AutoCAD SHX Text
CO
AutoCAD SHX Text
CO
450.6±
450.2±
450.5±
450.9±
448.4±
448.6±
448.2±
448.3±
447.5±
448.4±
451.2±
451.2±
LEGEND
PROPERTY LIMITS
CONSTRUCTION LIMITS
EXISTING MINOR CONTOUR
EXISTING MAJOR CONTOUR
PROPOSED MINOR CONTOUR
PROPOSED MAJOR CONTOUR
ADJACENT PROPERTY
BUILDING SETBACKS
PROPOSED STORM SEWER
PROPOSED DRAINTILE
OR ADVANEDGE
PROPOSED DRAINTILE
CLEANOUT
PROPOSED STORM MANHOLE
PROPOSED ACCESS DRIVE
EXISTING DECIDUOUS
TREES
EXISTING CONIFEROUS
TREES
INLET PROTECTION
CG-501
CG-501
CG-501
CG-501
Structural Engineering, Electrical Engineering:
AST
7301 Ohms Lane Edina, MN 55439
(952) 854-9302 John Levar
Irrigation:
Aqua Engineering 375 E. Horsetooth R Bldg. 2-202 Fort Collins, CO 80525
(907) 372-6104 Robert Beccard
Cost Estimating:
CPMI
3265 Northwood Circle Suite 170 Eagan, MN 55121
(952) 854-3663 Bryan Bertrand
Geotechnical Engineering:
Applied Geotechnical Engineering & Geologic Consulting 1314-B Center Drive #452 Medford, OR 97501
(541) 226-6658 Robin Warren
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
Fil e P ath
BID DOCUMENTS
U.S. Department of Veterans Affairs
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORDCONSULTANTS
321 4 5 6 7 8 9 10
Project Director
Revisions: Date:
o n e e i g h o t o n e q u a r t e r i n o t t h r e e e i g h o t o n e h a l f i n o t t h r e e q u a r t e o t o n e i n o t o n e a e h a l f i n o t t h r e e i n c h o t
A
B
C
D
E
F
1 3 6 0 5 1 s t A v e . N # 1 0 0 P l y m o u t h , M i n n e s o t a 5 5 4 4 1 P 763.412.4000 F 763.412 4090 ae-mn.com
ROSEBURG NATIONAL CEMETERY
GRAVESITE EXPANSION
ROSEBURG, OREGON
902CM3008
MAY 9, 2019 OF 59
#15135
BID DOCUMENTS
Office of Design and Construction
Services
R
E
G
I
S
T
E
R
E
D
PR
O
F
E
S
S
I
O
N
A
L
E
N
G
I N
E
E
R
83168
OREGON
G
A
R
Y
R
. J
O
H
N
S
O
N
J
U
L
Y
EXP. JUNE 30, 2019
Stamp y v a n c a r o s e b u r g n a t c e m e t e r y g r a v e s i t e e x p a n s i o n c i v i l c a d f i l e s
S
H E
E T
S C
G
R A
D I N
G d
P
M
N
0 10' 20'
SCALE:
GRADING ENLARGEMENT 1
1" = 10' (30" x 42" PAPER SIZE)
C.O.
R. 450.7
I. 445.1
C.O.
R. 450.1
I. 445.0
C.O.
R. 448.1
I. 445.3
C.O.
R. 448.5
I. 445.5
C.O.
R. 450.5
I. 446.0
C.O.
R. 450.0
I. 445.7
C.O.
R. 449.9
I. 445.3
KEY NOTES
INSTALL 45° 6X6 WYE AS SHOWN
INSTALL INLET PROTECTION
DOWNSTREAM OF CONSTRUCTION
INSTALL BIOROLL AT CONSTRUCTION
LIMITS
RESTORE DISTURBED AREA WITH 6"
TOPSOIL, SOD & IRRIGATION
P
R
O
P
E
R
T Y
L I N
E
P
R
O
P
E
R
N
E
CONSTRUCTION
LIMITS (TYP)
H
D
P
E
A
I
N
T
I
A
I
N
T
I
V
C
A
I
N
T
I
A
I
N
T
I
A
I
N
T
I
H
D P
E
D
R A
I N
T I
A
I
N
T
I
APPROXIMATE
LINE OF FLOOD
ZONE AREA
EX-M
CORE DRILL AND
CONNECT TO
EXISTING STRUCTURE
I. 444.3±
CG-501
(TYP.)
V
E
T E
R
A
N
W
A
Y
PROTECT
EXISTING
SIDEWALK
PROTECT
EXISTING
TREES (TYP.)
PROPOSED ACCESS
ROAD. SEE SHEET C-106
PROTECT EXISTING
IRRIGATION MAIN
PER AS-BUILT
DRAWINGS
PROTECT EXISTING
IRRIGATION MAIN &
FORCEMAIN (TYP.)
PROTECT EXISTING
UNDERGROUND
UTILIITES (TYP.)
CG-501
(TYP.)
GRADING ENLARGEMENT 1
CG-102
29GJ BF
AutoCAD SHX Text
RIM=447.5 INV=443.8
AutoCAD SHX Text
FILLED WITH WATER
AutoCAD SHX Text
NO VISIBLE OUTLET
AutoCAD SHX Text
8" PVC
AutoCAD SHX Text
6" PVC
AutoCAD SHX Text
6" PVC
AutoCAD SHX Text
6" PVC
AutoCAD SHX Text
14" PRESSURE PIPE
AutoCAD SHX Text
POSSIBLE EASEMENT PER VA PROVIDED RECORD PLANS
AutoCAD SHX Text
RIM=447.4 N. INV=444.3 E. INV=444.3 S. INV=444.1 W. INV=444.4
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
CO
AutoCAD SHX Text
CO
AutoCAD SHX Text
CO
AutoCAD SHX Text
CO
AutoCAD SHX Text
CO
AutoCAD SHX Text
CO
AutoCAD SHX Text
CO
AutoCAD SHX Text
RIM=447.4 N. INV=444.3 E. INV=444.3 S. INV=444.1 W. INV=444.4
3'- 35 8"
451.2±
CBMH-4
RIM 455.20
I. 452.00 (12" OUT)
55 LF -
12" RCP CL V
@ 0.55%
CBMH-3
RIM 456.30
I. 451.70 (12" IN)
I. 451.70 (12" OUT)
L
F R
C P
C L V
.8
STMH-2
RIM 454.50
I. 451.00 (12" IN)
I. 451.00 (12" OUT)
97 LF -
12" RCP CL V
@ 0.93%
FES-1
I. 450.10 (12" IN)
.1
456.5±
456.5±
456.5±
456.6±
456.6±
457.3±
456.8±
HP 456.1
456.35
456.35
LEGEND
PROPERTY LIMITS
CONSTRUCTION LIMITS
EXISTING MINOR CONTOUR
EXISTING MAJOR CONTOUR
PROPOSED MINOR CONTOUR
PROPOSED MAJOR CONTOUR
ADJACENT PROPERTY
BUILDING SETBACKS
PROPOSED STORM SEWER
PROPOSED DRAINTILE
OR ADVANEDGE
PROPOSED DRAINTILE
CLEANOUT
PROPOSED STORM MANHOLE
PROPOSED ACCESS DRIVE
EXISTING DECIDUOUS
TREES
EXISTING CONIFEROUS
TREES
INLET PROTECTION
CG-501
CG-501
CG-501
CG-501
Structural Engineering, Electrical Engineering:
AST
7301 Ohms Lane Edina, MN 55439
(952) 854-9302 John Levar
Irrigation:
Aqua Engineering 375 E. Horsetooth R Bldg. 2-202 Fort Collins, CO 80525
(907) 372-6104 Robert Beccard
Cost Estimating:
CPMI
3265 Northwood Circle Suite 170 Eagan, MN 55121
(952) 854-3663 Bryan Bertrand
Geotechnical Engineering:
Applied Geotechnical Engineering & Geologic Consulting 1314-B Center Drive #452 Medford, OR 97501
(541) 226-6658 Robin Warren
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
Fil e P ath
BID DOCUMENTS
U.S. Department of Veterans Affairs
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORDCONSULTANTS
321 4 5 6 7 8 9 10
Project Director
Revisions: Date:
o n e e i g h o t o n e q u a r t e r i n o t t h r e e e i g h o t o n e h a l f i n o t t h r e e q u a r t e o t o n e i n o t o n e a e h a l f i n o t t h r e e i n c h o t
A
B
C
D
E
F
1 3 6 0 5 1 s t A v e . N # 1 0 0 P l y m o u t h , M i n n e s o t a 5 5 4 4 1 P 763.412.4000 F 763.412 4090 ae-mn.com
ROSEBURG NATIONAL CEMETERY
GRAVESITE EXPANSION
ROSEBURG, OREGON
902CM3008
MAY 9, 2019 OF 59
#15135
BID DOCUMENTS
Office of Design and Construction
Services
R
E
G
I
S
T
E
R
E
D
PR
O
F
E
S
S
I
O
N
A
L
E
N
G
I N
E
E
R
83168
OREGON
G
A
R
Y
R
. J
O
H
N
S
O
N
J
U
L
Y
EXP. JUNE 30, 2019
Stamp y v a n c a r o s e b u r g n a t c e m e t e r y g r a v e s i t e e x p a n s i o n c i v i l c a d f i l e s
S
H E
E T
S C
G
R A
D I N
G d
P
M
N
0 10' 20'
SCALE:
GRADING ENLARGEMENT 2
1" = 10' (30" x 42" PAPER SIZE)
KEY NOTES
INSTALL 6X6 WYE & ROUND TO
ADVANTEDGE ADAPTERS FOR ALIGNMENT
AS SHOWN
EXISTING UNDERGROUND ELECTRICAL LINE
TO REMAIN IN PLACE (PROTECT).
PROTECT EXISTING CONCRETE WALK.
REPLACE IN-KIND IF DAMAGED DURING
CONSTRUCTION AT NO EXPENSE TO THE
OWNER.
FULL DEPTH SAWCUT AT CONCRETE WALK
JOINT. REPLACE PANELS AS NEEDED FOR
INSTALLATION OF STORM SEWER.
MAINTAIN SEPARATION BETWEEN SANITARY
AND STORM SEWER. PROTECT EXISTING
SANITARY SEWER.
INSTALL BIOROLL AT CONST. LIMITS
RESTORE DISTURBED AREA WITH 6"
TOPSOIL, SOD & IRRIGATION SYSTEM
REPAIR
C.O.
R. 458.0
I. 455.0
H
D P
E
A
D V
A N
E D
G
C.O.
R. 456.0
I. 453.0
CONSTRUCTION LIMITS
CONSTRUCTION LIMITS
A
I
N
T
I
TRENCH
DRAIN
CG-501
CG-501
(TYP.)
CG-501
C.O.
R. 458.1
I. 455.0
A
I
N
T
I
P
R
O
P
E
R
N
E
E X
I S
T I N
G
C
O N
C
W
A L K
O
M
A
A
C E
EXISTING IRRIGATION MAIN PER
AS-BUILT DRAWINGS (TYP.)
PROTECT EXISTING
IRRIGATION MAIN (TYP.)
CG-501
(TYP.)
C.O.
R. 456.0
I. 453.0
6" P V
C D
R A
IN
TILE
1.0%
GRADING ENLARGEMENT 2
CG-103
30GJ BF
AutoCAD SHX Text
INV=449.9
AutoCAD SHX Text
12" RCP
AutoCAD SHX Text
RIM=453.0 NE. INV=447.1 SW. INV=447.0
AutoCAD SHX Text
12" RCP
AutoCAD SHX Text
RIM=451.8 E. INV=446.9 W. INV=446.8
AutoCAD SHX Text
12" RCP
AutoCAD SHX Text
CO
AutoCAD SHX Text
CO
AutoCAD SHX Text
CO
AutoCAD SHX Text
CO
AutoCAD SHX Text
RIM=453.0 NE. INV=447.1 SW. INV=447.0
AutoCAD SHX Text
RIM=451.8 E. INV=446.9 W. INV=446.8
AutoCAD SHX Text
12" RCP
AutoCAD SHX Text
12" RCP
AutoCAD SHX Text
CO
AutoCAD SHX Text
EX SAN R. 454.1 I. 450.3 (E) I, 448.3 (W)
AutoCAD SHX Text
EX. 8" PVC SAN @ 1.67%
AutoCAD SHX Text
EX. 8" PVC SAN @ 1.18%
AutoCAD SHX Text
EXISTING STORMWATER POND HWL = 450.1
EXISTING FLAG ASSEMBLY AREA
CBMH-5
RIM 456.80
I. 451.15 (12" IN)
I. 451.15 (12" OUT)
CBHM-6
RIM 454.81
I. 451.59 (12" OUT)
F
32 LF -
12" RCP CL V
@ 0.50%
HP 455.1
455.7±
458.6±
458.7±
457.8±
456.4±
455.0±
LEGEND
PROPERTY LIMITS
CONSTRUCTION LIMITS
EXISTING MINOR CONTOUR
EXISTING MAJOR CONTOUR
PROPOSED MINOR CONTOUR
PROPOSED MAJOR CONTOUR
ADJACENT PROPERTY
BUILDING SETBACKS
PROPOSED STORM SEWER
PROPOSED DRAINTILE
OR ADVANEDGE
PROPOSED DRAINTILE
CLEANOUT
PROPOSED STORM MANHOLE
PROPOSED ACCESS DRIVE
EXISTING DECIDUOUS
TREES
EXISTING CONIFEROUS
TREES
INLET PROTECTION
CG-501
CG-501
CG-501
CG-501
Structural Engineering, Electrical Engineering:
AST
7301 Ohms Lane Edina, MN 55439
(952) 854-9302 John Levar
Irrigation:
Aqua Engineering 375 E. Horsetooth R Bldg. 2-202 Fort Collins, CO 80525
(907) 372-6104 Robert Beccard
Cost Estimating:
CPMI
3265 Northwood Circle Suite 170 Eagan, MN 55121
(952) 854-3663 Bryan Bertrand
Geotechnical Engineering:
Applied Geotechnical Engineering & Geologic Consulting 1314-B Center Drive #452 Medford, OR 97501
(541) 226-6658 Robin Warren
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
Fil e P ath
BID DOCUMENTS
U.S. Department of Veterans Affairs
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORDCONSULTANTS
321 4 5 6 7 8 9 10
Project Director
Revisions: Date:
o n e e i g h o t o n e q u a r t e r i n o t t h r e e e i g h o t o n e h a l f i n o t t h r e e q u a r t e o t o n e i n o t o n e a e h a l f i n o t t h r e e i n c h o t
A
B
C
D
E
F
1 3 6 0 5 1 s t A v e . N # 1 0 0 P l y m o u t h , M i n n e s o t a 5 5 4 4 1 P 763.412.4000 F 763.412 4090 ae-mn.com
ROSEBURG NATIONAL CEMETERY
GRAVESITE EXPANSION
ROSEBURG, OREGON
902CM3008
MAY 9, 2019 OF 59
#15135
BID DOCUMENTS
Office of Design and Construction
Services
R
E
G
I
S
T
E
R
E
D
PR
O
F
E
S
S
I
O
N
A
L
E
N
G
I N
E
E
R
83168
OREGON
G
A
R
Y
R
. J
O
H
N
S
O
N
J
U
L
Y
EXP. JUNE 30, 2019
Stamp y v a n c a r o s e b u r g n a t c e m e t e r y g r a v e s i t e e x p a n s i o n c i v i l c a d f i l e s
S
H E
E T
S C
G
R A
D I N
G d
P
M
N
0 10' 20'
SCALE:
GRADING ENLARGEMENT 3
1" = 10' (30" x 42" PAPER SIZE)
KEY NOTES
PROTECT EXISTING HEADSTONES
DURING CONSTRUCTION
MATCH PROPOSED GRADE TO BACK OF
CONCRETE CURB (TYP.)
INSTALL BIOROLL @ CONST. LIMITS
RESTORE AREA W/ 6" TOPSOIL
SOD & IRRIGATION REPAIR
PROTECT EXISTING GRID MONUMENT &
CLEANOUT
REMOVE & REPLACE GRAVESITE GRID
MONUMENT
INSTALL INLET PROTECTION DOWN
STREAM OF CONSTRUCTION.
PROTECT EXISTING UNDERDRAIN (TYP.)
EX-A
CORE DRILL AND
CONNECT TO EXISTING
STRUCTURE
I. 451.0±
C.O.
R. 457.8
I. 454.8
CONSTRUCTION
LIMITS
CG-501
C-507
M A
A
D
C.O.
R. 455.2
I. 452.2
12" HDPE
ADVANEDGE
@ 1.0%
EXISTING IRRIGATION
MAIN PER AS-BUILT
DRAWINGS (TYP.)
CG-501
GRADING ENLARGEMENT 3
CG-104
31GJ BF
EXISTING UNDERDRAIN
AS-BUILT DRAWINGS (TYP.)
AutoCAD SHX Text
12" RCP
AutoCAD SHX Text
4" PVC
AutoCAD SHX Text
15" RCP
AutoCAD SHX Text
12" RCP
AutoCAD SHX Text
15" RCP
AutoCAD SHX Text
12" RCP
AutoCAD SHX Text
4" PVC
AutoCAD SHX Text
4" DIP
AutoCAD SHX Text
4" DIP
AutoCAD SHX Text
12" RCP
AutoCAD SHX Text
CO
AutoCAD SHX Text
CO
AutoCAD SHX Text
CO
AutoCAD SHX Text
RIM=453.0 NE. INV=447.1 SW. INV=447.0
AutoCAD SHX Text
RIM=454.9 N. INV=447.6 E. INV=447.8 SW. INV=447.5
AutoCAD SHX Text
RIM=457.8 NE. INV=453.5 INV=453.5 E. INV=453.3 SE. INV=451.2 NW. INV=451.0
AutoCAD SHX Text
12" RCP
AutoCAD SHX Text
15" RCP
AutoCAD SHX Text
CO
EXISTING PPC SECTION 1
CBMH-7
RIM 463.00
I. 459.30 (12" OUT)
30 LF -
12" RCP CL V
@ 2.00%
463.6±
463.9±
464.5±
463.8±
464.0±
.5
.5
465.4±
465.9±
465.5±
LEGEND
PROPERTY LIMITS
CONSTRUCTION LIMITS
EXISTING MINOR CONTOUR
EXISTING MAJOR CONTOUR
PROPOSED MINOR CONTOUR
PROPOSED MAJOR CONTOUR
ADJACENT PROPERTY
BUILDING SETBACKS
PROPOSED STORM SEWER
PROPOSED DRAINTILE
OR ADVANEDGE
PROPOSED DRAINTILE
CLEANOUT
PROPOSED STORM MANHOLE
PROPOSED ACCESS DRIVE
EXISTING DECIDUOUS
TREES
EXISTING CONIFEROUS
TREES
INLET PROTECTION
CG-501
CG-501
CG-501
CG-501
Structural Engineering, Electrical Engineering:
AST
7301 Ohms Lane Edina, MN 55439
(952) 854-9302 John Levar
Irrigation:
Aqua Engineering 375 E. Horsetooth R Bldg. 2-202 Fort Collins, CO 80525
(907) 372-6104 Robert Beccard
Cost Estimating:
CPMI
3265 Northwood Circle Suite 170 Eagan, MN 55121
(952) 854-3663 Bryan Bertrand
Geotechnical Engineering:
Applied Geotechnical Engineering & Geologic Consulting 1314-B Center Drive #452 Medford, OR 97501
(541) 226-6658 Robin Warren
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
Fil e P ath
BID DOCUMENTS
U.S. Department of Veterans Affairs
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORDCONSULTANTS
321 4 5 6 7 8 9 10
Project Director
Revisions: Date:
o n e e i g h o t o n e q u a r t e r i n o t t h r e e e i g h o t o n e h a l f i n o t t h r e e q u a r t e o t o n e i n o t o n e a e h a l f i n o t t h r e e i n c h o t
A
B
C
D
E
F
1 3 6 0 5 1 s t A v e . N # 1 0 0 P l y m o u t h , M i n n e s o t a 5 5 4 4 1 P 763.412.4000 F 763.412 4090 ae-mn.com
ROSEBURG NATIONAL CEMETERY
GRAVESITE EXPANSION
ROSEBURG, OREGON
902CM3008
MAY 9, 2019 OF 59
#15135
BID DOCUMENTS
Office of Design and Construction
Services
R
E
G
I
S
T
E
R
E
D
PR
O
F
E
S
S
I
O
N
A
L
E
N
G
I N
E
E
R
83168
OREGON
G
A
R
Y
R
. J
O
H
N
S
O
N
J
U
L
Y
EXP. JUNE 30, 2019
Stamp y v a n c a r o s e b u r g n a t c e m e t e r y g r a v e s i t e e x p a n s i o n c i v i l c a d f i l e s
S
H E
E T
S C
G
R A
D I N
G d
P
M
N
0 10' 20'
SCALE:
GRADING ENLARGEMENT 4
1" = 10' (30" x 42" PAPER SIZE)
KEY NOTES
PROTECT EXISTING IN GROUND CREMAINS
DURING CONSTRUCTION (TYP.)
INSTALL & MAINTAIN BIOROLL @ CONST.
LIMITS
RESTORE DISTURBED AREA W/ 6" TOPSOIL
SOD & IRRIGATION REPAIR
REMOVE & REPLACE GRAVESITE GRID
MONUMENT
INSTALL INLET PROTECTION DOWN
STREAM OF CONSTRUCTION
PROTECT EXISTING WATERMAIN IN-PLACE
C.O.
R. 465.5
I. 462.5
C.O.
R. 464.1
I. 461.1
A
I
N
T
I
CG-501
CG-501
(TYP.)
V
A
N
E
D
CONSTRUCTION
LIMITS
CONSTRUCTION
LIMITS
EX-B
CORE DRILL AND
CONNECT TO
EXISTING STRUCTURE
I. 458.7±
C-507
EXISTING IRRIGATION
MAIN PER AS-BUILT
DRAWINGS (TYP.)
EX-C
GRADING ENLARGEMENT 4
CG-105
32GJ BF
EXISTING 1" PVC
WM PER AS-BUILT
DRAWINGS (TYP.)
AutoCAD SHX Text
12" RCP
AutoCAD SHX Text
4" PVC
AutoCAD SHX Text
12" RCP
AutoCAD SHX Text
4" PVC
AutoCAD SHX Text
4" PVC
AutoCAD SHX Text
CO
AutoCAD SHX Text
CO
AutoCAD SHX Text
RIM=464.0 (BEEHIVE) W. INV=455.2
AutoCAD SHX Text
12" RCP
AutoCAD SHX Text
RIM=463.6 N. INV=461.3 NE. INV=455.3 SW. INV=455.2
AutoCAD SHX Text
RIM=462.8 N. INV=454.7 SE.INV=460.5 SW. INV=454.4
AutoCAD SHX Text
12" RCP
AutoCAD SHX Text
RIM=463.9 NW. INV=458.9 12" RCP
AutoCAD SHX Text
CO
EXISTING IGC SECTION 6
CBMH-8
RIM 463.43
I. 459.70 (12" OUT)
HP 469.3
CBMH -9
RIM 466.00
I. 459.67 (12" OUT)
27 LF -
12" RCP CL V
@ 1.00%
.0
4.0
467.8
465.6
466.6
465.7
466.3
467.4
468.6
469.3
468.9
467.9
466.3
467.3
468.3
468.7
LEGEND
PROPERTY LIMITS
CONSTRUCTION LIMITS
EXISTING MINOR CONTOUR
EXISTING MAJOR CONTOUR
PROPOSED MINOR CONTOUR
PROPOSED MAJOR CONTOUR
ADJACENT PROPERTY
BUILDING SETBACKS
PROPOSED STORM SEWER
PROPOSED DRAINTILE
OR ADVANEDGE
PROPOSED DRAINTILE
CLEANOUT
PROPOSED STORM MANHOLE
PROPOSED ACCESS DRIVE
EXISTING DECIDUOUS
TREES
EXISTING CONIFEROUS
TREES
INLET PROTECTION
CG-501
CG-501
CG-501
CG-501
Structural Engineering, Electrical Engineering:
AST
7301 Ohms Lane Edina, MN 55439
(952) 854-9302 John Levar
Irrigation:
Aqua Engineering 375 E. Horsetooth R Bldg. 2-202 Fort Collins, CO 80525
(907) 372-6104 Robert Beccard
Cost Estimating:
CPMI
3265 Northwood Circle Suite 170 Eagan, MN 55121
(952) 854-3663 Bryan Bertrand
Geotechnical Engineering:
Applied Geotechnical Engineering & Geologic Consulting 1314-B Center Drive #452 Medford, OR 97501
(541) 226-6658 Robin Warren
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
Fil e P ath
BID DOCUMENTS
U.S. Department of Veterans Affairs
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORDCONSULTANTS
321 4 5 6 7 8 9 10
Project Director
Revisions: Date:
o n e e i g h o t o n e q u a r t e r i n o t t h r e e e i g h o t o n e h a l f i n o t t h r e e q u a r t e o t o n e i n o t o n e a e h a l f i n o t t h r e e i n c h o t
A
B
C
D
E
F
1 3 6 0 5 1 s t A v e . N # 1 0 0 P l y m o u t h , M i n n e s o t a 5 5 4 4 1 P 763.412.4000 F 763.412 4090 ae-mn.com
ROSEBURG NATIONAL CEMETERY
GRAVESITE EXPANSION
ROSEBURG, OREGON
902CM3008
MAY 9, 2019 OF 59
#15135
BID DOCUMENTS
Office of Design and Construction
Services
R
E
G
I
S
T
E
R
E
D
PR
O
F
E
S
S
I
O
N
A
L
E
N
G
I N
E
E
R
83168
OREGON
G
A
R
Y
R
. J
O
H
N
S
O
N
J
U
L
Y
EXP. JUNE 30, 2019
Stamp y v a n c a r o s e b u r g n a t c e m e t e r y g r a v e s i t e e x p a n s i o n c i v i l c a d f i l e s
S
H E
E T
S C
G
R A
D I N
G d
P
M
N
0 10' 20'
SCALE:
GRADING ENLARGEMENT 5
1" = 10' (30" x 42" PAPER SIZE)
KEY NOTES
MATCH PROPOSED GRADE TO BACK OF
CONCRETE CURB (TYP.)
INSTALL AND MAINTAIN BIOROLL @
CONSTRUCTION LIMITS.
INSTALL AND MAINTAIN INLET
PROTECTION DOWN STREAM OF
CONSTRUCTION.
CONTINUE GRADE EXTENDING 5'
BEYOND I.G.C. LIMITS.
PROTECT EXISTING 1" PVC WATERMAIN
IN PLACE
MAINTAIN 18" VERTICAL SEPARATION
BETWEEN WATER AND STORM. VERIFY
EXISTING WATERMAIN IS LOCATED 3.5'
BELOW EXISTING GRADE.
EX-D
CORE DRILL AND
CONNECT TO EXISTING
STRUCTURE I. 458.9±
EX-F
CORE DRILL
AND CONNECT
TO EXISTING
STRUCTURE
I. 459.4±
CONSTRUCTION
LIMITS (TYP.)
CG-501
CG-501
C.O.
R. 468.9
I. 465.9
C.O.
R. 466.0
I. 463.0
H
D
A
I N
T
I
A
I N
T
I
C.O.
R. 464.8
I. 462.2
H
D
A
I N
T
I
TEST PIT 3
SEE SHEET B-101 FOR
MORE INFORMATION
TEST PIT 4
SEE SHEET B-101 FOR
MORE INFORMATION
PROTECT
EXISTING TREE
TYP.
CG-501
TYP.
A
I N
T
I
C.O.
R. 469.0
I. 466.0
M
A
A
D
EXISTING IRRIGATION
MAIN PER AS-BUILT
DRAWINGS (TYP.)
E
X
E
GRADING ENLARGEMENT 5
CG-106
33GJ BF
AutoCAD SHX Text
CO
AutoCAD SHX Text
CO
AutoCAD SHX Text
CO
AutoCAD SHX Text
CO
AutoCAD SHX Text
CO
AutoCAD SHX Text
RIM=463.4 NE. INV=457.1 SE. INV=457.8 SW. INV=460.1 W. INV=456.5
AutoCAD SHX Text
RIM=463.9 NW. INV=458.9 12" RCP
AutoCAD SHX Text
RIM=463.4 SE. INV=458.6 SW. INV=460.8 NW. INV=458.6
AutoCAD SHX Text
RIM=465.5 N. INV=459.1 S. INV=462.4 SW. INV=459.0
AutoCAD SHX Text
18" RCP
AutoCAD SHX Text
4" PVC
AutoCAD SHX Text
12" RCP
AutoCAD SHX Text
4" PVC
CBMH-13
RIM 472.88
I. 465.90 (12" IN)
I. 464.14 (18" IN)
I. 464.14 (18" OUT)
474.9±
474.8±
475.1
474.9
474.8
474.85
474.85
475.0
474.9
475.0
475.0
474.9
475.0
475.0
475.1
475.0
475.1
474.8
475.0
474.9
474.7
474.75
474.7
474.8
474.85
474.8
474.5
474.5
474.5
474.6
474.7
474.85
474.8
474.8
474.8
474.65
474.65474.65
474.65
474.85
474.8
474.65
474.65
474.65 474.65
474.8
475.0
474.7
4:1
1.7%
1.9%
1.9%
1.8%
1.9%
474.9
474.95
474.95
475.0
475.0
475.0
474.95
474.8
474.80
CB-14
RIM 474.60
I. 466.40 (12" OUT)
I. 466.40 (12" IN)
P
CBMH-12
RIM 474.40
I. 467.40 (8" IN)
I. 466.20 (12" OUT)
I. 466.20 (12" IN)
39 LF -
8" HDPE
@ 4.00%
CBMH-11
RIM 474.39
I. 468.98 (8" IN)
I. 468.98 (8" OUT)
CB-10
RIM 474.40
I. 470.40 (8" OUT)
474.85474.85
35 LF -
8" HDPE PIPE
@ 4.00%
45° BEND
45° BEND
HP 474.8
474.8±
474.9±
474.9±
474.9±
CB-15
RIM 474.00
I. 466.18 (12" OUT)
37 LF -
12" HDPE PIPE
@ 0.53%
LEGEND
PROPERTY LIMITS
CONSTRUCTION LIMITS
EXISTING MINOR CONTOUR
EXISTING MAJOR CONTOUR
PROPOSED MINOR CONTOUR
PROPOSED MAJOR CONTOUR
ADJACENT PROPERTY
BUILDING SETBACKS
PROPOSED STORM SEWER
PROPOSED DRAINTILE
OR ADVANEDGE
PROPOSED DRAINTILE
CLEANOUT
PROPOSED STORM MANHOLE
PROPOSED ACCESS DRIVE
EXISTING DECIDUOUS
TREES
EXISTING CONIFEROUS
TREES
INLET PROTECTION
CG-501
CG-501
CG-501
CG-501
Structural Engineering, Electrical Engineering:
AST
7301 Ohms Lane Edina, MN 55439
(952) 854-9302 John Levar
Irrigation:
Aqua Engineering 375 E. Horsetooth R Bldg. 2-202 Fort Collins, CO 80525
(907) 372-6104 Robert Beccard
Cost Estimating:
CPMI
3265 Northwood Circle Suite 170 Eagan, MN 55121
(952) 854-3663 Bryan Bertrand
Geotechnical Engineering:
Applied Geotechnical Engineering & Geologic Consulting 1314-B Center Drive #452 Medford, OR 97501
(541) 226-6658 Robin Warren
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
Fil e P ath
BID DOCUMENTS
U.S. Department of Veterans Affairs
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORDCONSULTANTS
321 4 5 6 7 8 9 10
Project Director
Revisions: Date:
o n e e i g h o t o n e q u a r t e r i n o t t h r e e e i g h o t o n e h a l f i n o t t h r e e q u a r t e o t o n e i n o t o n e a e h a l f i n o t t h r e e i n c h o t
A
B
C
D
E
F
1 3 6 0 5 1 s t A v e . N # 1 0 0 P l y m o u t h , M i n n e s o t a 5 5 4 4 1 P 763.412.4000 F 763.412 4090 ae-mn.com
ROSEBURG NATIONAL CEMETERY
GRAVESITE EXPANSION
ROSEBURG, OREGON
902CM3008
MAY 9, 2019 OF 59
#15135
BID DOCUMENTS
Office of Design and Construction
Services
R
E
G
I
S
T
E
R
E
D
PR
O
F
E
S
S
I
O
N
A
L
E
N
G
I N
E
E
R
83168
OREGON
G
A
R
Y
R
. J
O
H
N
S
O
N
J
U
L
Y
EXP. JUNE 30, 2019
Stamp y v a n c a r o s e b u r g n a t c e m e t e r y g r a v e s i t e e x p a n s i o n c i v i l c a d f i l e s
S
H E
E T
S C
G
R A
D I N
G d
P
M
N
0 10' 20'
SCALE:
GRADING ENLARGEMENT 6
1" = 10' (30" x 42" PAPER SIZE)
KEY NOTES
CONSTRUCT CBMH-13 OVER EXISTING
18" RCP AT ELEVATION 464.1±.
INSTALL AND MAINTAIN BIOROLL @
BASE OF CONSTRUCTION FENCE ON
CONSTRUCTION SIDE.
INSTALL AND MAINTAIN INLET
PROTECTION DOWNSTREAM OF
CONSTRUCTION.
CONSTRUCTION
LIMITS (TYP.)
TEST PIT 1
SEE SHEET B-101 FOR
MORE INFORMATION
M
A
A
D
EX-I
RE-CONSTRUCT
MANHOLE TO RIM
ELEVATION = 474.4
SWALE ℄
EXISTING IRRIGATION MAIN PER
AS-BUILT DRAWINGS (TYP.)
N
0 10' 20'
SCALE:
COLUMBARIUM DRAINTILE ENLARGEMENT
1" = 10' (30" x 42" PAPER SIZE)
CG-501
CG-501
CG-501
CG-501
CG-501
COLUMBARIA
CLEANOUT (TYP.)
COLUMBARIA
CLEANOUT (TYP.)
COLUMBARIA
CLEANOUT (TYP.)
COLUMBARIA
CLEANOUT (TYP.)
COLUMBARIA
CLEANOUT (TYP.)
CG-501
CG-501
CG-501
CG-501
CG-501
EX-H
EX-J
EX-K
GRADING ENLARGEMENT 6
CG-107
34GJ BF
AutoCAD SHX Text
18" RCP
AutoCAD SHX Text
RIM=468.5 N. INV=465.4 NE. INV=463.0 S. INV=462.3
AutoCAD SHX Text
18" RCP
AutoCAD SHX Text
RIM=474.6 E. INV=467.1 W. INV=466.6
AutoCAD SHX Text
12" RCP
AutoCAD SHX Text
RIM=474.8 SE. INV=466.0 SW. INV=465.3
AutoCAD SHX Text
EXISTING 1" PVC
AutoCAD SHX Text
CO
AutoCAD SHX Text
18" RCP
AutoCAD SHX Text
RIM=474.6 E. INV=467.1 W. INV=466.6
AutoCAD SHX Text
12" RCP
RIM=474.8 SE. INV=466.0 SW. INV=465.3
CB-16
RIM 474.00
I. 470.30 (12" OUT)
HP 474.9
474.9±
474.8±
474.9±
474.9±
474.9±
474.6±
474.1±
475.0±
474.9±
475.0±
474.85
475.0
475.0
474.8±
474.9±
474.9±
474.9±
LEGEND
PROPERTY LIMITS
CONSTRUCTION LIMITS
EXISTING MINOR CONTOUR
EXISTING MAJOR CONTOUR
PROPOSED MINOR CONTOUR
PROPOSED MAJOR CONTOUR
ADJACENT PROPERTY
BUILDING SETBACKS
PROPOSED STORM SEWER
PROPOSED DRAINTILE
OR ADVANEDGE
PROPOSED DRAINTILE
CLEANOUT
PROPOSED STORM MANHOLE
PROPOSED ACCESS DRIVE
EXISTING DECIDUOUS
TREES
EXISTING CONIFEROUS
TREES
INLET PROTECTION
CG-501
CG-501
CG-501
CG-501
Structural Engineering, Electrical Engineering:
AST
7301 Ohms Lane Edina, MN 55439
(952) 854-9302 John Levar
Irrigation:
Aqua Engineering 375 E. Horsetooth R Bldg. 2-202 Fort Collins, CO 80525
(907) 372-6104 Robert Beccard
Cost Estimating:
CPMI
3265 Northwood Circle Suite 170 Eagan, MN 55121
(952) 854-3663 Bryan Bertrand
Geotechnical Engineering:
Applied Geotechnical Engineering & Geologic Consulting 1314-B Center Drive #452 Medford, OR 97501
(541) 226-6658 Robin Warren
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
Fil e P ath
BID DOCUMENTS
U.S. Department of Veterans Affairs
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORDCONSULTANTS
321 4 5 6 7 8 9 10
Project Director
Revisions: Date:
o n e e i g h o t o n e q u a r t e r i n o t t h r e e e i g h o t o n e h a l f i n o t t h r e e q u a r t e o t o n e i n o t o n e a e h a l f i n o t t h r e e i n c h o t
A
B
C
D
E
F
1 3 6 0 5 1 s t A v e . N # 1 0 0 P l y m o u t h , M i n n e s o t a 5 5 4 4 1 P 763.412.4000 F 763.412 4090 ae-mn.com
ROSEBURG NATIONAL CEMETERY
GRAVESITE EXPANSION
ROSEBURG, OREGON
902CM3008
MAY 9, 2019 OF 59
#15135
BID DOCUMENTS
Office of Design and Construction
Services
R
E
G
I
S
T
E
R
E
D
PR
O
F
E
S
S
I
O
N
A
L
E
N
G
I N
E
E
R
83168
OREGON
G
A
R
Y
R
. J
O
H
N
S
O
N
J
U
L
Y
EXP. JUNE 30, 2019
Stamp y v a n c a r o s e b u r g n a t c e m e t e r y g r a v e s i t e e x p a n s i o n c i v i l c a d f i l e s
S
H E
E T
S C
G
R A
D I N
G d
P
M
N
0 10' 20'
SCALE:
GRADING ENLARGEMENT 7
1" = 10' (30" x 42" PAPER SIZE)
KEY NOTES
PROTECT EXISTING COLUMBARIUM
THROUGHOUT CONSTRUCTION.
REPLACE IN KIND IF DAMMAGED AT NO
EXPENSE TO THE OWNER (TYP)
INSTALL & MAINTAIN BIOROLL @ CONST.
LIMITS
RESTORE DISTURBED AREA W/ 6"
TOPSOIL
SOD & IRRIGATION REPAIR
PROTECT EXISTING TREES
INSTALL AND MAINTAIN INLET
PROTECTION DOWNSTREAM OF
CONSTRUCTION.
EX-L
CORE DRILL AND CONNECT
TO EXISTING STRUCTURE
I. 467.3±
CONSTRUCTION
LIMITS (TYP.)
A
A
MATCH
MATCH
MATCH
PROTECT EXISTING
IRRIGATION MAIN PER
AS-BUILT DRAWINGS
(TYP.)
GRADING ENLARGEMENT 7
CG-108
35GJ BF
AutoCAD SHX Text
RIM=474.6 E. INV=468.4 W. INV=468.1
AutoCAD SHX Text
12" RCP
AutoCAD SHX Text
RIM=474.8 SE. INV=466.0 SW. INV=465.3
AutoCAD SHX Text
RIM=472.5 W. INV=463.6
AutoCAD SHX Text
RIM=472.5 W. INV=463.6
AutoCAD SHX Text
RIM=474.8 SE. INV=466.0 SW. INV=465.3
AutoCAD SHX Text
EXISTING 1" PVC WM
7'-1 15 8"
7'-1 15 8"
473.1±
473.0±
472.9±
472.9±
472.8
472.8
LEGEND
PROPERTY LIMITS
CONSTRUCTION LIMITS
EXISTING MINOR CONTOUR
EXISTING MAJOR CONTOUR
PROPOSED MINOR CONTOUR
PROPOSED MAJOR CONTOUR
ADJACENT PROPERTY
BUILDING SETBACKS
PROPOSED STORM SEWER
PROPOSED DRAINTILE
OR ADVANEDGE
PROPOSED DRAINTILE
CLEANOUT
PROPOSED STORM MANHOLE
PROPOSED ACCESS DRIVE
EXISTING DECIDUOUS
TREES
EXISTING CONIFEROUS
TREES
INLET PROTECTION
CG-501
CG-501
CG-501
CG-501
Structural Engineering, Electrical Engineering:
AST
7301 Ohms Lane Edina, MN 55439
(952) 854-9302 John Levar
Irrigation:
Aqua Engineering 375 E. Horsetooth R Bldg. 2-202 Fort Collins, CO 80525
(907) 372-6104 Robert Beccard
Cost Estimating:
CPMI
3265 Northwood Circle Suite 170 Eagan, MN 55121
(952) 854-3663 Bryan Bertrand
Geotechnical Engineering:
Applied Geotechnical Engineering & Geologic Consulting 1314-B Center Drive #452 Medford, OR 97501
(541) 226-6658 Robin Warren
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
Fil e P ath
BID DOCUMENTS
U.S. Department of Veterans Affairs
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORDCONSULTANTS
321 4 5 6 7 8 9 10
Project Director
Revisions: Date:
o n e e i g h o t o n e q u a r t e r i n o t t h r e e e i g h o t o n e h a l f i n o t t h r e e q u a r t e o t o n e i n o t o n e a e h a l f i n o t t h r e e i n c h o t
A
B
C
D
E
F
1 3 6 0 5 1 s t A v e . N # 1 0 0 P l y m o u t h , M i n n e s o t a 5 5 4 4 1 P 763.412.4000 F 763.412 4090 ae-mn.com
ROSEBURG NATIONAL CEMETERY
GRAVESITE EXPANSION
ROSEBURG, OREGON
902CM3008
MAY 9, 2019 OF 59
#15135
BID DOCUMENTS
Office of Design and Construction
Services
R
E
G
I
S
T
E
R
E
D
PR
O
F
E
S
S
I
O
N
A
L
E
N
G
I N
E
E
R
83168
OREGON
G
A
R
Y
R
. J
O
H
N
S
O
N
J
U
L
Y
EXP. JUNE 30, 2019
Stamp y v a n c a r o s e b u r g n a t c e m e t e r y g r a v e s i t e e x p a n s i o n c i v i l c a d f i l e s
S
H E
E T
S C
G
R A
D I N
G d
P
M
N
0 10' 20'
SCALE:
GRADING ENLARGEMENT 8
1" = 20' (30" x 42" PAPER SIZE)
KEY NOTES
INSTALL 15X6 SADDLE WYE AS SHOWN
OR INSERTA-TEE. CORE DRILL INTO SIDE
OF EXISTING 15" RCP STORM DRAIN
PROTECT EXISTING CONCRETE WALK.
REPLACE IN-KIND IF DAMAGED DURING
CONSTRUCTION AT NO ADDITIONAL COST
TO THE GOVERNMENT.
FULL DEPTH SAWCUT AT CONCRETE
WALK JOINT. REPLACE PANELS AS
NEEDED FOR INSTALLATION OF STORM
SEWER.
INSTALL AND MAINTAIN BIOROLL @
CONSTRUCTION LIMITS
RESTORE DISTURBED AREA W/ 6"
TOPSOIL SOD & IRRIGATION REPAIR
PROTECT EXISTING TREES
INSTALL AND MAINTAIN INLET
PROTECTION DOWNSTREAM OF
CONSTRUCTION.
CONSTRUCTION
LIMITS (TYP.)
D
R
A
I
N
T
I
CG-501
TRENCH
DRAIN
CG-501
I. 463.4
I. 467.8
R
F
O
R
A
T
P
E
PROTECT EXISTING
IRRIGATION MAIN PER
AS-BUILT DRAWINGS
(TYP.)
EX-L
GRADING ENLARGEMENT 8
CG-109
36GJ BF
AutoCAD SHX Text
RIM=472.5 W. INV=463.6
AutoCAD SHX Text
15" RCP
AutoCAD SHX Text
RIM=472.5 W. INV=463.6
AutoCAD SHX Text
15" RCP
SECONDARY GCL COLLAR
PRIMARY GCL LAYER
HORIZONTAL PIPE
NOTE: SOIL COVER NOT SHOWN.
PRIMARY GCL LAYER
COMPACTED SUBGRADE
SECONDARY GCL COLLAR, 12" OVERLAP
GRANULAR BENTONITE
HORIZONTAL PIPE
SOIL COVER
STRUCTURE LC
PRECAST CONCRETE
MANHOLE SECTION
ADJUST TO FINISH GRADE
W/ MH BRICK OR
CONCRETE GRADE RINGS
1/2" POINTING
R-2595-A NEENA FOUNDARY
FRAME AND GRATE
APPROVED EQUAL
SLOPE 1" TO 6"
CONCRETE FILL
MORTAR
FOUNDATION SLAB (TYP.)
6" PRECAST OR 8" CAST
IN PLACE
2'
4'
1/12 DIA.
MIN.
1'-4"
MAX.
5"
TYP.
8" MIN.
12" MAX.
2', 3', & 4'
ECCENTRIC CONES
OR FLAT SLAB
RIM ELEV.
6"
GRANULAR
BACKFILL
2"
MIN.
UNLESS OTHERWISE
NOTED ON PLANS
7 14"
FLOW CHANNEL
GROUT OPENING
WATER TIGHT
' F
OR
" P
IP
E, ' F
OR
" A
ND
" P
IP
E
2'
4 TIMES PIPE DIAMETER
EXTEND RIPRAP 1' BEYOND END OF
FLARED END SECTION AT FULL DEPTH
FLARED END SECTION
RIPRAP STRIP AROUND BASIN
RIPRAP AT FLARED END SECTION DETAIL
EXTEND RIPRAP ON SIDE
SLOPE TO TOP OF FLARED
END SECTION OPENING
RIPRAP TOP SET AT 449.5
RIPRAP BASE SET AT 448
SE
E
CH
AR
T
FO
R
LE
NG
TH
12"
TOPSOIL AND SEED
16" DEEP RIPRAP
FINISH GRADE
PIPE
SECTION
PIPE: EXTEND RIPRAP
1' BEYOND END
OF DISCHARGE
PIPE AND ON
(CONTINUOUS)
RIPRAP GEOTEXTILE
4 TIMES PIPE DIAMETER
PLAN
FLARED END SECTION
SEE CHART FOR LENGTH
OR AS INDICATED
ON PLANS
CLEARED AND GRUBBED
SUBGRADE
SIDE SLOPE TO
TOP OF PIPE
CULVERT (PIPE) WITH
FLARED END SECTION
CULVERT
SIZE, DIA.
INCH.
MIN. DEPTH
AND WIDTH
MIN.
LENGTH
FEET
12-18
1 X 4 1 X 6 1 X 7
ROCK LINING FOR CULVERT OUTLETS
FEET
NOTE:
CONTRACTOR TO SUBMIT SAMPLE OF RIPRAP, 6 TO 12" DIA
FOR REVIEW AND APPROVAL BY COR
CLEANOUT - END OF LINE
45° BEND
FINISH GRADE
45° BEND
THREADED PLUG END
PVC RISER
CLEANOUT - IN LINE / CONNECTION POINT
THREADED PLUG END
MATERIAL PER PLAN
TEE
FINISH GRADE
45° BEND
MATERIAL PER PLAN
WYE
MAINLINE
NOTE:
CONTRACTOR TO PROVIDE
AS-BUILT COORDINATES OF
ALL CLEANOUT LOCATIONS
TO COR.
6" DEEP BY 18" DIA.
CONCRETE RING
CAST IRON FRAME &
GRATE, MARKED C.O.
OR BLANK
CAST IRON FRAME
MAIN LINE
O.D. £ 12", W=30" O.D.=15"-24",W=O.D.+18" O.D.=30"-36",W=O.D.+24"
80/20 PLANTING MEDIA (NON
PAVED AREAS) GRANULAR
BACKFILL (PAVED AREAS)
SLOPE PER OSHA SAFETY
STANDARDS
GRANULAR DRAINAGE
BACKFILL MATERIAL
TO WITHIN 12" OF SURFACE
W=MAX.
TRENCH
WIDTH
4 O.D.
MIN. 4"
MAX 8"
UNDISTURBED SOIL
12" FINISHED
SURFACE
FINISHED GRADE
SEE PLANS FOR MATERIALS
1' MIN. O.D.
80/20
PLANTING
MEDIA
NONWOVEN
TYPE 1
DRAINAGE
GEOTEXTILE.
OVERLAP 12"
MIN
B c
18"
Bc/8, 4" MIN
GRANULAR DRAINAGE
BACKFILL MATERIAL
PERFORATED PIPE SLOPED
TO OUTLET AS SHOWN ON
PLANS (0.5% MIN.)
TYPICAL BEDDING SECTION
LINE OF TRENCH
SIDES PER OSHA
REQUIREMENTS
4" MIN.
6.1"
6"
SECTION A-A
A
A
V A
R I E
S
12" RCP PIPE (TYP.) SLOPE PER PLAN
CONCRETE SIDE WALK WIDTH
ANCHOR STAKE (REBAR)
STRUCTURAL FILL
4" HDPE PIPE
12" RCP PIPE
INSERTA-TEE
OR UNI-T
ACO SlabDrain OR
EQUAL CHANNEL DRAIN
ADA COMPLIANT AND
HEEL SAFE DUCTILE
IRON OR STAINLESS
STEEL GRATE
RISER PIPES IN CONC. WALK
ALIGNED W/ BOTTOM KNOCK-OUT
ON CHANNEL DRAIN
INSERTA-TEE OR UNI-T
ACO SlabDrain OR
EQUAL CHANNEL DRAIN
ADA COMPLIANT AND HEEL SAFE ACO,
OR APPROVED EQUAL, DUCTILE IRON
OR STAINLESS STEEL GRATE
E.J.
UPSTREAM
STRUCTURE
DOWNSTREAM
STRUCTURE
4" CONCRETE SIDEWALK THICKENED TO 8",
4" FROM EITHER SIDE OF CHANNEL DRAIN
NOTES
1. TRENCH MUST BE NO LESS THAN 4" WIDE
2. MINIMUM COVER SHALL BE NO LESS THAN 4"
3. MINIMUM SLOPE TO VARY AS REQUIRED TO
PROVIDE POSITIVE DRAINAGE.
DISTURBANCE OF 36" OR
2 SOD ROLL WIDTHS MAX
12" 80/20 PLANTING MEDIA
WASHED PEA GRAVEL
12" ADVANEDGE PIPE
12"
GEOTEXTILE FABRIC PER
MANUFACTURE
RECOMMENDATIONS
EXISTING
CONCRETE WALK
5'
INVERT PER PLAN
80/20 PLANTING MEDIA
100' MAX
100' MAX.
4" PVC
6"x4" RED.
LONG SWEEP
90° BEND
4" PVC
6"x4" RED.
LONG SWEEP
90° BEND
WYE
PVC C.O. CAP
TOP OF PVC C.O. CAP SHALL BE PLACED 2"
BELOW FINISHED DECORATIVE GRAVEL
SURFACE AS TO HIDE CLEANOUT, BUT
PROVIDE ACCESS AS NEEDED FOR
MAINTENANCE.
3" DEEP
DECORATIVE GRAVEL
DRAINAGE AGGREGATE
MAIN
LINE
Structural Engineering, Electrical Engineering:
AST
7301 Ohms Lane Edina, MN 55439
(952) 854-9302 John Levar
Irrigation:
Aqua Engineering 375 E. Horsetooth R Bldg. 2-202 Fort Collins, CO 80525
(907) 372-6104 Robert Beccard
Cost Estimating:
CPMI
3265 Northwood Circle Suite 170 Eagan, MN 55121
(952) 854-3663 Bryan Bertrand
Geotechnical Engineering:
Applied Geotechnical Engineering & Geologic Consulting 1314-B Center Drive #452 Medford, OR 97501
(541) 226-6658 Robin Warren
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
Fil e P ath
BID DOCUMENTS
U.S. Department of Veterans Affairs
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORDCONSULTANTS
321 4 5 6 7 8 9 10
Project Director
Revisions: Date:
o n e e i g h o t o n e q u a r t e r i n o t t h r e e e i g h o t o n e h a l f i n o t t h r e e q u a r t e o t o n e i n o t o n e a e h a l f i n o t t h r e e i n c h o t
A
B
C
D
E
F
1 3 6 0 5 1 s t A v e . N # 1 0 0 P l y m o u t h , M i n n e s o t a 5 5 4 4 1 P 763.412.4000 F 763.412 4090 ae-mn.com
ROSEBURG NATIONAL CEMETERY
GRAVESITE EXPANSION
ROSEBURG, OREGON
902CM3008
MAY 9, 2019 OF 59
#15135
BID DOCUMENTS
Office of Design and Construction
Services
R
E
G
I
S
T
E
R
E
D
PR
O
F
E
S
S
I
O
N
A
L
E
N
G
I N
E
E
R
83168
OREGON
G
A
R
Y
R
. J
O
H
N
S
O
N
J
U
L
Y
EXP. JUNE 30, 2019
Stamp y v a n c a r o s e b u r g n a t c e m e t e r y g r a v e s i t e e x p a n s i o n c i v i l c a d f i l e s
S
H E
E T
S C
G
R A
D I N
U
I L I T
Y
D
E T
A I L S d
P
M
ISOMETRIC
SECTION
SCALE:
FIBER ROLL PROTECTION
(INLET OF CULVERT)
N.T.S.
SCALE:
CATCH BASIN / STORM MANHOLE SECTION
1/2" = 1'-0" SCALE:
CLEANOUT SECTION
1" = 1'-0" SCALE:
PIPE BEDDING SECTION
1/2" = 1'-0"
SCALE:
UNDERDRAIN SECTION
1" = 1'-0"
SCALE:
FLARED END SECTION
1" = 1'-0"
SCALE:
RIPRAP SECTION & PLAN
1" = 1'-0" SCALE:
HORIZONTAL PIPE PENETRATION DETAIL
( FOR PIPE INTO POND )
1/2" = 1'-0"
SCALE:
TRENCH DRAIN PLAN & SECTION VIEW
N.T.S.
SCALE:
ADVANEDGE DRAINTILE DETAIL
NTS
SCALE:
CLEANOUT - COLUMBARIA FLOWER STRIP
N.T.S.
GRADING & UTILITY DETAILS
CG-501
37GJ BF
Structural Engineering, Electrical Engineering:
AST
7301 Ohms Lane Edina, MN 55439
(952) 854-9302 John Levar
Irrigation:
Aqua Engineering 375 E. Horsetooth R Bldg. 2-202 Fort Collins, CO 80525
(907) 372-6104 Robert Beccard
Cost Estimating:
CPMI
3265 Northwood Circle Suite 170 Eagan, MN 55121
(952) 854-3663 Bryan Bertrand
Geotechnical Engineering:
Applied Geotechnical Engineering & Geologic Consulting 1314-B Center Drive #452 Medford, OR 97501
(541) 226-6658 Robin Warren
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
Fil e P ath
BID DOCUMENTS
U.S. Department of Veterans Affairs
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORDCONSULTANTS
321 4 5 6 7 8 9 10
Project Director
Revisions: Date:
o n e e i g h o t o n e q u a r t e r i n o t t h r e e e i g h o t o n e h a l f i n o t t h r e e q u a r t e o t o n e i n o t o n e a e h a l f i n o t t h r e e i n c h o t
A
B
C
D
E
F
1 3 6 0 5 1 s t A v e . N # 1 0 0 P l y m o u t h , M i n n e s o t a 5 5 4 4 1 P 763.412.4000 F 763.412 4090 ae-mn.com
ROSEBURG NATIONAL CEMETERY
GRAVESITE EXPANSION
ROSEBURG, OREGON
902CM3008
MAY 9, 2019 OF 59
#15135
BID DOCUMENTS
Office of Design and Construction
Services
R
E
G
I
S
T
E
R
E
D
PR
O
F
E
S
S
I
O
N
A
L
E
N
G
I N
E
E
R
83168
OREGON
G
A
R
Y
R
. J
O
H
N
S
O
N
J
U
L
Y
EXP. JUNE 30, 2019
Stamp y v a n c a r o s e b u r g n a t c e m e t e r y g r a v e s i t e e x p a n s i o n c i v i l c a d f i l e s
S
H E
E T
S C
E
R O
S I O
N
C
O N
T R
O L d
P M
INITIAL
A COMPREHENSIVE LIST OF AVAILABLE BEST MANAGEMENT PRACTICES (BMP) OPTIONS BASED ON DEQ's GUIDANCE
MANUAL HAS BEEN REVIEWED T0 COMPLETE THIS ER0SION AND SEDIMENT C0NTR0L PLAN SOME OF THE ABOVE
LISTED BMP's WERE NOT CHOSEN BECAUSE THEY WERE DETERMINED T0 NOT EFFECTIVELY MANAGE ER0SION
PREVENTI0N AND SEDIMENT C0NTR0L F0R THIS PROJECT BASED ON SPECIFIC SITE CONDITI0NS INCLUING SOIL
C0NDITIONS TOPOGRAPHIC CONSTRAINTS ACESSIBILITY TO THE SITE AND OTHER RELATED CONDITIONS AS THE
PROJECT PROGRESSES AND THERE IS A NEED TO REVISE THE ESC PLAN, AN ACTION PLAN WILL BE SUBMITTED
EROSION AND SEDIMENT CONTROL PLANS
SHEET INDEX
RATIONALE STATEMENT
REFER TO DEQ GUIDANCE MANUAL FOR A COMPREHENSIVE LIST OF
AVAILABLE BMP'S
BMP MATRIX FOR CONSTRUCTION PHASES
LOCAL AGENCY-SPECIFIC EROSION
CONTROL NOTES:
VICINITY MAP
PROJECT LOCATION: PROPERTY DESCRIPTION:
ATTENTION EXCAVATORS:
SITE MAP
SITE CONDITION MINIMUM FREQUENCY
STANDARD EROSION AND SEDIMENT
CONTROL PLAN DRAWING NOTES:
DEVELOPER
NARRATIVE DESCRIPTIONS
EXISTING SITE CONDITIONS
DEVELOPED CONDITIONS
NATURE OF CONSTRUCTION ACTIVITY AND ESTIMATED TIME TABLE
* CLEARING (DATES, FROM & TO:_________________________ )
* MASS GRADING (DATES, FROM & TO ___________________________ )
* UTILITY INSTALLATION (DATES, FROM & TO ____________________________ )
* STREET CONSTRUCTION (DATES, FROM & TO_____________________________ )
* FINAL STABILIZATION DATES, FROM & TO______________________________ )
PERMITTEES SITE INSPECTOR
DESCRIPTION OF EXPERIENCE:
FAX:
PHONE:
COMPANY/AGENCY:
EMAIL:
INSPECTI0N FREQUENCY:
NOT TO SCALE
N
PROJECT SITE
EROSION AND SEDIMENT CONTROL PLAN (ESCP) DRAWINGS
NOT TO SCALE
N
ENGINEERING & SURVEY FIRM: ANDERSON ENGINEERING OF MN, LLC
13605 1ST AVENUE NORTH, SUITE 100
PLYMOUTH, MN 55441
CONTACT: GARY JOHNSON, PROJECT MANAGER
PHONE: (763) 412-4000
DEVELOPER/OWNER: ROSEBURG NATIONAL CEMETERY
913 NW GARDEN VALLEY BLVD
ROSEBURG, OR 97471
CONTACT:
PHONE:
THE EXISTING SITE IS A RELATIVELY NEW NATIONAL CEMETERY WITH
AN INCLUSION OF IN GROUND BERIALS SECTIONS, FLAG ASSEMBLY
AREA, COLUMBARIUM, P.I.C. BUILDING WITH ROADWAYS COMPLETE
WITH CURB AND GUTTER.
EXPANSION OF THE EXISTING COLUMBARIUM AREA. THE NEW
COLUMBARIUM WILL BE LOCATED SOUTH OF THE EXISTING UNITS.
THE COLUMBARIUM WALLS ARE RELATIVELY LIGHTLY LOADED
STRUCTURES SUPPORTED ON SPREAD FOOTING FOUNDATIONS.
CONCRETE WALKWAYS WILL BE LOCATED ADJACENT TO THE
COLUMBARIA WALLS AND FOR ACCESS TO THE WALLS.
THE NEW IMPROVEMENTS WILL ALSO INCLUDE A CREMAINS BURIAL
AREA. THE BURIAL AREAS WILL BE LOCATED SOUTH/SOUTWEST OF
THE NEW COLUMBARIUM.
A NUMBER OF DRAINAGE IMPROVEMENT AREAS ARE SCATTERED
THROUGHOUT THE PROJECT SITE.
SITE SOIL CLASSIFICATION:
T.B.D.
TEST PIT 1
0.0 TO 2.0 FT MEDIUM STIFF, BROWN CLAYEY SILT; MODERATELY EXPANSIVE, DUFF/ROOTED
ZONE AT GROUND SURFACE.
3.0 TO 4.0 FT MEDIUM STIFF TO STIFF, BROWN SILT, SOME SMALL RIVER GRAVEL, TRACE CLAY AND
SILT.
GROUNDWATER SEEPAGE NOT OBSERVED.
NO SIGNIFICANT CAVING OF TEST PIT SIDEWALLS.
TEST PIT 2
0.0 TO 2.0 FT MEDIUM STIFF, GRAY CLAYEY SILT; MODERATELY EXPANSIVE, DUFF/ROOTED ZONE AT
GROUND SURFACE.
3.0 TO 4.0 FT MEDIUM STIFF TO STIFF, BROWN SILT; SOME SMALL RIVER GRAVEL, TRACE CLAY AND
SILT.
GROUNDWATER SEEPAGE NOT OBSERVED.
NO SIGNIFICANT CAVING OF TEST PIT SIDEWALLS.
TEST PIT 3
0.0 TO 1.5 FT FILL: STIFF, BROWN SILT; SCATTERED ANGULAR GRAVEL AND COBBLE, DRY.
1.5 TO 3.0 FT MEDIUM STIFF, GRAY CLAYEY SILT; MODERATELY EXPANSIVE, MOIST.
3.0 TO 4.0 FT MEDIUM HARD (RH-2), BROWN SILTSTONE, CLOSE FRACTURES, SLIGHTLY WEATHERED.
GROUNDWATER SEEPAGE NOT OBSERVED.
NO SIGNIFICANT CAVING OF TEST PIT SIDEWALLS.
TEST PIT 4
0.0 TO 2.0 FT FILL: STIFF, BROWN SILT; SCATTERED ANGULAR GRAVEL AND COBBLE, DRY.
1.5 TO 3.0 FT MEDIUM STIFF, GRAY CLAYEY SILT; MODERATELY EXPANSIVE, MOIST.
3.0 TO 4.0 FT MEDIUM HARD (RH-2), BROWN SILTSTONE, CLOSE FRACTURES, SLIGHTLY WEATHERED.
GROUNDWATER SEEPAGE NOT OBSERVED.
NO SIGNIFICANT CAVING OF TEST PIT SIDEWALLS.
NOTE: TEST PITS COMPLETED AUGUST 28, 2018. SEE COMPLETE GEOTECHNICAL REPORT BY AGEGC, SEPTEMBER 15, 2018 FOR ADDITIONAL INFORMATION.
RECEIVING WATER BODIES:
NEAREST WATER BODY: SOUTH UMPQUA RIVER
YEAR
BMP'S MONTH #
PIPE SLOPE DRAINS
ENERY DISSIPATERS
TEMPORARY DIVERSION DIKES
CHECK DAMS
TEMPORARY SEEDING AND PLANTING
PERMANENT SEEDING AND PLANTING
MYCRORHIZAE/BIOFERTILIZERS
MULCHES (SPECIFY TYPE)
CONSTRUCTION ENTRANCE
COMPOST BLANKETS
COMPOST SOCKS
COMPOST BERM
SOIL TACKIFIERS
SODDING VEGETATIVE BUFFER STRIPS
SEDIMENT FENCING
EROSION CONTROL BALNKETS & MATS (SPECIFY TYPE)
EARTH DIKES (STABILIZED)
DRAINAGE SWALES
ROCK OUTLET PROTECTION
SEDIMENT TRAP
STRAW WATTLES (LOOSE COMPACTION RICE STRAW)
STORM DRAIN INLET PROTECTION
TEMPORARY OR PERMANENT SEDIMENTATION BASINS
CONTRUCTION ENTRANCE
UNPAVED ROADS GRAVELED OR OTHER BMP ON THE ROAD
DEWATERING (TREATMENT LOCATION, CHEMATIC, & SAMPLING PLAN REQUIRED)
PAVING OPERATIONS CONTROLS
CONCRETE TRUCK WASHOUT
CE-101 STORMWATER POLLUTION PREVENTION PLAN
CE-102 EROSION CONTROL OVERALL
CE-501 EROSION CONTROL DETAILS
TOTAL SITE AREA = 1,895,296 SF = 43.51 ACRES
TOTAL DISTURBED AREA = 96,237 SF = 2.21 ACRES
913 NW GARDEN VALLEY BLVD
ROSEBURG, OR 97471, DOUGLAS
COUNTY, OREGON
LATITUDE = 43.2219
LONGITUDE = -123.3635
TAX LOTS 27061300300
(DOUGLAS COUNTY TAX MAP)
SECTION: S13 T27S R6W,
WILLAMETTE MERIDIAN, OREGON
PLANNING/ENGINEERING/
SURVEYING FIRM
OREG0N LAW REQUIRES YOU TO FOLLOW RULES ADOPTED BY THE OREGON UTILITY NOTIFICATION CENTER THOSE RULES
ARE SET FORTH IN OAR 952-001-0010 THROUGH OAR 952-001-0090. YOU MAY OBTAIN COPIES OF THESE RULES FROM THE
CENTER BY CALLING 503-232-1987. IF YOU HAVE ANY QUESTIONS ABOUT THE RULES, YOU MAY CONTACT THE CENTER.
YOU MUST NOTIFY THE CENTER AT LEAST TWO BUSINESS DAYS BEF0RE COMMENCING AN EXCAVATION CALL 503-246-6699.
· HOLD A PRE-CON MEETING OF PROJECT CONSTRUCTION PERSONNEL THAT INCLUDES THE EC
INSPECTOR.
· ALL INSPECTIONS MUST BE MADE IN ACCORDANCE WITH DEQ 1200 C PERMIT REQUIREMENTS.
· INSPECTION LOGS MUST BE KEPT IN ACCORDANCE WITH DEQ'S 1200 C PERMIT REQUIREMENTS.
· REVISIONS TO THE APPROVED ESC PLAN MUST BE SUBMITTED TO DEQ OR AGENT IN ACCORDANCE
WITH CURRENT 1200-C PERMIT.
1. ACTIVE PERIOD
2. PRIOR TO THE SITE BECOMING INACTIVE OR IN
ANTICIPATION OF SITE INACCESSIBILITY
3. INACTIVE PERIODS GREATER THAN FOURTEEN (14)
CONSECUTIVE CALENDAR DAYS
4. PERIODS DURING WHICH THE SITE IS INACCESSIBLE
DUE TO INCLEMENT WEATHER
IF PRACTICAL, INSPECTIONS MUST OCCUR DAILY AT A
RELEVANT AND ACCESSIBLE DISCHARGE POINT OR
DOWNSTREAM LOCATION
0NCE EVERY TW0 (2) WEEKS
ONCE T0 ENSURE THAT EROSION AND SEDIMENT CONTROL
MEASURES ARE IN WORKING ORDER ANY NECESSARY
MAINTENANCE AND REPAIR MUST BE MADE PRIOR TO LEAVING
THE SITE
DAILY WHEN STORMWATER RUN0FF, INCLUDING RUNOFF FROM
SNOWMELT, IS OCCURRING AT LEAST ONCE EVERY TWO (2)
WEEKS REGARDLESS OF WETHER STORMWATER RUNOFF IS
OCCURRING
1. OWNER OR DESIGNATED PERSON SHALL BE RESPONSIBLE FOR PROPER INSTALLATION AND MAINTENANCE OF ALL
EROSION AND SEDIMENT CONTROL MEASURES, IN ACCORDANCE WITH LOCAL, STATE, AND FEDERAL REGULATIONS
2. PRIOR TO ANY LAND DISTURBING ACTIVITIES, THE BOUNDARIES OF THE CLEARING LIMITS, VEGETATED BUFFERS, AND ANY SENSITIVE AREAS SHOWN ON THIS PLAN SHALL BE CLEARLY DELINEATED IN THE FIELD DURING THE
CONSTRUCTION PERIOD, NO DISTURBANCE IS PERMITTED BEYOND THE CLEARING LIMITS THE OWNER/PERMITTEE
MUST MAINTAIN IN THE DELINEATION FOR THE DURATION OF THE PROJECT. NOTE: VEGATATED CORRIDORS TO BE
DELINEATED WITH ORANCE CONSTRUCTION FENCE OR APPROVED EQUAL.
3. PRIOR TO ANY LAND DISTURBING ACTIVITIE, THE BMP's THAT MUST BE INSTALLED ARE A GRAVEL CONSTRUCTION
ENTRANCE, PERIMETER SEDIMENT CONTROL, AND INLET PROTECTI0N THESE BMPs MUST BE MAINTAINED FOR THE
DURATION 0F THE PROJECT.
4. IF VEGETATIVE SEED MIXES ARE SPECIFIED, SEEDING MUST TAKE PLACE NO LATER THAT SEPTEMBER 1; THE TYPE AND
PERCENTAGES OF SEED IN THE MIX MUST BE IDENTIFIED ON THE PLANS
5. ALL PUMPING OF SEDIMENT LADEN WATER SHALL BE DISCHARGED OVER AN UNDISTURBED, PREFERABLY VEGETATED
AREA, AND THR0UGH A SEDIMENT CONTROL BMP i.e. (FILTER BAG).
6. THE ESC PLAN MUST BE ΚEPT ON SITE. ALL MEASURES SHOWN ON THE PLAN MUST BE INSTALLED PR0PERLY T0
ENSURE THAT SEDIMENT OR SEDIMENT LADEN WATER DOES NOT ENTER A SURFACE WATER SYSTEM ROADWAY OR
OTHER PROPERTIES.
7. THE ESC MEASURES SHOWN ON THIS PLAN ARE MINIMUM REQUIREMENTS FOR ANTICIPATED SITE CONDITI0NS. DURING
THE CONSTRUCTION PERIOD, THESE MEASURES SHALL BE UPGRADED AS NEEDED TO COMPLY WITH ALL APPLICABLE
LOCAL, STATE, AND FEDERAL EROSION CONTROL REGULATIONS . CHANGES TO THE APPROVED ESC PLAN MUST BE
SUBMITTED IN THE FORM OF AN ACTION PLAN TO DEQ PER THE 1200 C PERMIT.
8. IN AREAS SUBJECT TO WIND EROSION, APPROPRIATE BMP's MUST BE USED WHICH MAY INCLUDE THE APPLICATION 0F
FINE WATER SPRAYING, PLASTIC SHEETING, MULCHING, OR OTHER APPROVED MEASURES.
9. ALL EXPOSED SOILS MUST BE COVERED DURING THE WET WEATHER PERIOD.
THE PERMITTEE IS REQUIRED TO MEET ALL THE CONDITI0NS OF THE 1200C PERMIT. THIS ESCP AND
GENERAL CONDITIONS HAVE BEEN DEVELOPED TO FACILITATE COMPLIANCE WITH THE 1200C PERMIT
REQUIREMENTS. IN CASES OF DISCREPANCIES OR OMISSIONS, THE 1200C PER IT REQUIREMENTS
SUPERCEDE REQUIREMENTS OF THIS PLAN.
1. Hold a pre-construction meeting of project construction personnel that includes the inspector to discuss erosion and sediment control measures and construction limits. (Schedule A.8.c.i.(3))
2. All inspections must be made in accordance with DEQ 1200-C permit requirements.
3. Inspection logs must be kept in accordance with DEQ’s 1200-C permit requirements.
4. Retain a copy of the ESCP and all revisions on site and make it available on request to DEQ, Agent, or the local municipality. During inactive periods of greater than seven (7) consecutive calendar days, retain the ESCP at the construction site or at another location.
(Schedule B.2.a)
5. All permit registrants must implement the ESCP. Failure to implement any of the control measures or practices described in the ESCP is a violation of the (Schedule A 8.a)
6. The ESCP measures shown on this plan are minimum requirements for anticipated site conditions. During the construction period, upgrade these measures as needed to comply with all applicable local, state, and federal erosion and sediment control regulations.
(Schedule A.8.c.ii.(1)(c))
7. Submission of all ESCP revisions is not required. Submittal of the ESCP revisions is only under specific conditions. Submit all necessary revision to DEQ or Agent. (Schedule A.12.c.iii)
8. Phase clearing and grading to the maximum extent practical to prevent exposed inactive areas from becoming a source of erosion.
(Schedule A 8.c.ii.(1)(d))
9. Identify, mark, and protect (by fencing off or other means) critical riparian areas and vegetation including important trees and associated rooting zones, and vegetation areas to be preserved. Identify vegetative buffer zones between the site and sensitive areas (e.g., wetlands), and other areas to be preserved, especially in perimeter areas. (Schedule A.8.c.i.(1) & (2))
10. Preserve existing vegetation when practical and re-vegetate open areas. Re-vegetate open areas when practicable before and after grading or construction.Identify the type of vegetative seed mix used. (Schedule A.7.b.iii(1) and A.7.b.iii(3))
11. Erosion and sediment control measures including perimeter sediment control must be in place before vegetation is disturbed and must remain in place and be maintained, repaired, and promptly implemented following procedures established for the duration of construction, including protection for active storm drain inlets and catch basins and appropriate non-stormwater pollution controls. (Schedule A.7.d.i and A.8.c)
12. Establish concrete truck and other concrete equipment washout areas before beginning concrete work. (Schedule A.8.c.i.(6))
13. Apply temporary and/or permanent soil stabilization measures immediately on all disturbed areas as grading progresses and for all roadways including gravel roadways. (Schedule A.8.c.ii.(2))
14. Establish material and waste storage areas, and other non-stormwater controls. (Schedule A.8.c.i.(7))
15. Prevent tracking of sediment onto public or private roads using BMPs such as: graveled (or paved) exits and parking areas, gravel all unpaved roads located onsite, or use an exit tire wash. These BMPs must be in place prior to land-disturbing activities. (Schedule A
7.d.ii.(1) and A.8.c.i(4))
16. When trucking saturated soils from the site, either use water-tight trucks or drain loads on site. (Schedule A.7.d.ii.(3))
17. Use BMPs to prevent or minimize stormwater exposure to pollutants from spills; vehicle and equipment fueling, maintenance, and storage; other cleaning and maintenance activities; and waste handling activities. These pollutants include fuel, hydraulic fluid, and other oils from vehicles and machinery, as well as debris, leftover paints, solvents, and glues from construction operations. (Schedule
A.7.e.i.(2))
18. Implement the following BMPs when applicable: written spill prevention and response procedures, employee training on spill prevention and proper disposal procedures, spill kits in all vehicles, regular maintenance schedule for vehicles and machinery, material delivery and storage controls, trainingand signage, and covered storage areas for waste and supplies. (Sch A 7.e.iii.)
19. Use water, soil-binding agent or other dust control technique as needed to avoid wind-blown soil. (Schedule A 7.b.ii)
20. The application rate of fertilizers used to reestablish vegetation must follow manufacturer’s recommendations to minimize nutrient releases to surface Exercise caution when using time-release fertilizers within any waterway riparian zone. (Schedule A.9.b.iii)
21. If a stormwater treatment system (for example, electro-coagulation, flocculation, filtration, etc.) for sediment or other pollutant…