IFB Attachment 12 - Geotechnical Report.pdf

PDF 10 MB Posted

Attached to
Y1DZ--Construct Women's Health Clinic Project 537-327 Chicago, IL - Jesse Brown VAMC
Solicitation number
36C77625B0012
Issued by

About this file

This document appears to be a Blood Hound underground utility locating service report for the Jesse Brown VA Medical Center in Chicago, IL. The service report details a utility locating and ground-penetrating radar (GPR) scan performed on 2/26/2024, with technician David Niesen conducting the work. The report includes multiple photographs documenting utility markings, anomalies, and the location of electrical lines, storm lines, and sanitary lines across the medical center's grounds.

The service report includes technical notes indicating that the subsurface utility designation was performed using radio frequency (RF) and ground-penetrating radar (GPR) methods. The technician documented several observations, including electrical lighting configurations, storm drainage routes, and GPR scan results. The report emphasizes that utility depths are approximate and would require test holes for precise confirmation. The documentation includes detailed aerial maps, ground-level images showing red-marked utility paths, and close-up images of utility access points and infrastructure.

View the file

Other files

Show all 16

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SERVICE REPORT

Blood Hound, LLC

(888) 858-9830 Office

(888) 858-9829 Fax

BHUG.com

BLOOD HOUND strives to provide quality and accurate locating services to all of its customers, but due to the nature of privately owned underground facilities, BLOOD HOUND will not be held liable for any damaged facilities. All customers are advised that they are required to follow their state's One-Call-Law before beginning excavation. BLOOD HOUND. will not guarantee the longevity of utility markings, due to activities on site that may destroy, or otherwise alter, the markings that were placed on the ground by BLOOD HOUND. If the marks have been altered or destroyed, the customer is advised to contact BLOOD HOUND. for remarkings. If the customer fails to pay the balance in full by the due date, the customer shall be obligated to pay reasonable interest, and shall be responsible for all costs of collection that BLOOD HOUND incurs, including attorney fees, court costs, and other costs of collection. Any electronically determined depths provided to the client are estimates only and due to limitation of equipment cannot be guaranteed. Client acknowledges that due to the limitations of the equipment used, safe exposure and measurements are the only methods which can precisely determine location and depth of structures marked. I hereby acknowledge the satisfactory completion of the above work and that i have received and understand the documents describing the limitations of the technologies employed, and agree to pay for charges as indicated above. Invoices are due 30 days from the invoice date (net 30), unless otherwise stated on this form or pre-authorized agreement between BLOOD HOUND and client. If the client has entered into a separate, signed and executed Tier 4 agreement, or other liability and terms contract between the client and BLOOD HOUND then the provisions of this statement will be considered null and void and the terms of the separate agreement will supersede these terms.

Disclaimer

Copyright © 2024 Blood Hound, LLC- All Rights Reserved

N

00247558 Customer NTSWork order# Scale:Jesse Brown VA Medical Center

820 S Damen Ave, Chicago, IL, 60612

BHUG.COM

1. The subsurface utilities depicted are for informational use only. Blood Hound is not a licensed surveyor or Engineering firm.

Independent verification of the provided data for any official use would be required.

2. Our subsurface utility designation was performed utilizing radio frequency (RF) and ground penetrating radar (GPR). Electromagnetic interference and subsurface soil and groundwater conditions impact the ability to identify and trace subsurface utilities.

3. Unless confirmed with test holes, any subsurface utility depths shown hereon were derived with RF or GPR methodologies and are approximate.

4. The base map imagery shown may not reflect current site conditions.

5. Designated subsurface utilities were designated using a Vivax-Metrotech vLoc3 RTK-Pro GNSS receiver, unless otherwise noted.

Legend

Work type Locating David NiesenTechnician(s) Address

6500 Technology Center Drive Suite 200 Indianapolis, IN 46278

1-888-858-9830

Elec. Entrance Elec. Line GPR Anomaly Locator Sanitary Line Storm Line

Storm Manhole

VHACHSThakkJ1 Highlight

00247558_V1_Redacted
Capture-of-the-area-to-be-GPR Scanning - 02132024 - Copy
Jesse Brown VA 00247558 sketch - Copy
Jesse Brown VA 00247558 pics - REDUCED

File details come from the government source that posted it. Updated .