This document appears to be a drawing or schematic that is part of a larger attachment related to the Department of Veterans Affairs' solicitation for "VHA Construction Project 674-21-700 EHRM OIT Infrastructure Upgrades - Olin E. Teague VAMC - Temple TX". The solicitation is for construction services to upgrade the information technology infrastructure at the Olin E. Teague VAMC facility in Temple, Texas. The solicitation number is 36C77624R0091 and the procuring agency is the VA Technology Acquisition Center in Austin, Texas. No other specific details about the required products or services, response dates, award information, pricing, or set-asides are provided in this particular document.
View the file
Other files
Show all 25
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
W
AP
FLOOR PLAN LEGEND
CARD READER, REF TELECOM DRAWINGS
DATA PORT, REF TELECOM DRAWINGS
OUTLET, REF ELEC DRAWINGS
WIRELESS ACCESS POINT, REF TELECOM
DRAWINGS
ELEC PANEL, REF ELEC DRAWINGS
STRIP LIGHT FIXTURE, REF ELEC DRAWINGS
(E) FIRE EXTINGUISHER LOCATION
SEE 00-GI-002 - PROJECT GENERAL NOTES AND CODE SUMMARY
1. GENERAL PLAN NOTES
2. GENERAL DEMOLITION PLAN NOTES
3. GENERAL REFLECTED CEILING PLAN NOTES
PLAN NOTES: SEE GI-SHEETS
2x2 LIGHT FIXTURE
2x4 LIGHT FIXTURE
STRIP LIGHT FIXTURE
6" RECESSED CAN LIGHT FIXTURE
SUPPLY AIR DIFFUSER
RETURN AIR VENT
EXHAUST FAN
5/8" GYP. BOARD CEILING AFFIXED TO 3 5/8" MTL STUDS
2'x2' SUSPENDED ACOUSTIC CEILING TILE CEILING
RCP LEGEND
HATCH INDICATES AREA NOT IN SCOPE OF WORK
INDICATES BUILT ITEM TO BE REMOVED
INDICATES LIGHT FIXTURE TO BE REMOVED
DEMOLITION LEGEND
PROJECT KEY PLAN
CENTRAL TEXAS VETERANS HEALTH CARE SYSTEM
CTVHCS NETWORK #674
1901 VETERANS MEMORIAL DRIVE | TEMPLE, TEXAS 76504
NORTH
74746
A
B
D
C
A
C D
B
E W
EHRM ROOM ALLOCATION
PROJECT
NORTH
TR #221.21
2A-133A LAUNDRY
2A-135
LOCKERS
2A-133
EMS
2A-133B
BEDROOM
2B-129
CORR
2-243
09-03
09-03
02-50
EXP
88 SF
TR #221.21
2A-133A LAUNDRY
2A-135
LOCKERS
2A-133
EMS
2A-133B
BEDROOM
2B-129
CORR
2-243
8'
10' - 4"
1-
2A
3A .1
PROJECT
NORTH
AE-221-302
PROJECT
NORTH
02-03
TR #221.21
2A-133A LAUNDRY
2A-135
LOCKERS
2A-133
EMS
2A-133B
BEDROOM
2B-129
CORR
2-243
PROJECT
NORTH
02-50
09-03
09-03
EXP
LOCKERS
2C-133
MED ROOM
2C-132
TR #221.22
2C-133A
EMS
2C-133B
BEDROOM
2D-129
CORR
2D-
LOCKERS
2C-133
MED ROOM
2C-132
87 SF
TR #221.22
2C-133A
EMS
2C-133B
BEDROOM
2D-129
CORR
2D-
10' - 4"
8'
1-
2C
3A .1
PROJECT
NORTH
AE-221-302
PROJECT
NORTH
LOCKERS
2C-133
MED ROOM
2C-132
TR #221.22
2C-133A
EMS
2C-133B
BEDROOM
2D-129
CORR
2D-
02-03
TR #221.21
2A-133A
09-01
06-01
1-
2A
3A .1
8'
6"
4' - 6"
09-11
09-03
TR #221.21
2A-133A
8'
6"
06-01
09-01
09-11
09-03
TR #221.21
2A-133A
09-01
06-01
6" 8'
09-11
09-03
06-01
TR #221.21
2A-133A
8'
6"
06-01
09-01
09-11
09-03
TR #221.22
2C-133A
1-
2C
3A .1
8'
6"
1' - 6"
06-01
09-01
09-11
09-03
09-01
06-01
TR #221.22
2C-133A
8'
6"
09-11
09-03
TR #221.22
2C-133A
6" 8'
06-01
09-01
06-01
09-11
09-03
TR #221.22
2C-133A
09-01
06-01
8'
6"
09-11
09-03
U.S. Department of Veterans Affairs
VA FORM 08 - 6231
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
321 4 5 6 7 8 9 10
PROJECT NUMBER
BUILDING NUMBER
DRAWING NUMBER
PROJECT TITLE
LOCATION
ISSUE DATE CHECKED BY DRAWN BY
DRAWING TITLE
APPROVED:
PHASE
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
FLS
PROGRAM
CONTRACTING
ACTIVITY
CENTRAL (PCAC)
A u to d e s k D o c s /6
-2
-7
C
T V
H C
S
T e m p le
E H
R M
/2 B ld g r2
.r v t
-0
-2
:1
:5
AE-221-302
LEVEL 2 ENLARGED PLANS AND
ELEVATIONSA&E DESIGN
129 NORTH 29th STREET, SUITE 100
BILLINGS, MT 59101
PH: 406.248.2633
<To Be Determined>, AIA
GDM OF OREGON
1000 W STEUBEN ST, UNIT 3
BINGEN, WA 98605
PH: 541.224.8536
ADAM GOODIN, PE
EHRM INFRASTRUCTURE UPGRADE
TEMPLE, TEXAS
674-21-700
CHARLES R. YALE, R.A.
JPRSO06/27/2023
95% CONSTRUCTION
DOCUMENTS
A/E:ARCHITECT:
FULLY SPRINKLERED
BUILDING 221
KEYNOTES
KEY COMMENT
02-03 CAREFULLY REMOVE EXISTING DOOR, FRAME AND HARDWARE, RETURN TO
OWNER.
02-50 DEMO EXISTING GYPSUM BOARD CEILING, LIGHT FIXTURES AND ANY CEILING
MOUNTED DEVICES; REMOVE EXISTING SPRINKLER HEADS AND TURN UP
DISCHARGE PIPE, PROVIDE NEW FIRE SUPPRESSION HEADS FOR EXPOSED
CONDITIONS
06-01 INSTALL 3/4" AC GRADE OR BETTER FIRE RETARDANT PLYWOOD; PAINT WITH
TWO COATS OF SEMI-GLOSS BRIGHT WHITE FIRE RETARDANT PAINT; MOUNT
BOTTOM OF PLYWOOD 6" A.F.F., TOP OF PLYWOOD AT 8'-6" A.F.F.; DO NOT
PAINT OVER STAMPED PLYWOOD RATING
09-01 PAINT GYPSUM BOARD WALL WITH SEMI GLOSS PAINT IN ITS ENTIRETY,
COLOR TO MATCH PLYWOOD PAINT.
09-03 WHERE EXISTING WALL DOES NOT EXTEND TO UNDERSIDE OF STRUCTURE,
PROVIDE NEW GYPSUM BOARD WALL FROM TOP OF EXISTING WALL TO
UNDERSIDE OF STRUCTURE TO FULLY ENCLOSE TR ROOM, SEAL AS PER
DETAILS ON G-SHEETS.
09-11 INSTALL NEW WALL BASE TO MATCH TYPE, COLOR, AND PROFILE OF
EXISTING WALL BASE
1/4" = 1'-0"1
2A-133A TR #221.21 REFLECTED CEILING PLAN
1/4" = 1'-0"2
LEVEL 2 - 2A-133A TR #221.21 ENLARGED PLAN
1/4" = 1'-0"3
2A-133A TR #221.21 DEMOLITION PLAN
1/4" = 1'-0"6
2A-133A TR #221.22 REFLECTED CEILING PLAN
1/4" = 1'-0"7
LEVEL 2 - 2C-133A TR #221.22 DEMOLITION PLAN
1/4" = 1'-0"8
2A-133A TR #221.22 DEMOLITION PLAN
1/4" = 1'-0"11
2A-133A TR #221.21 - NORTH VIEW
1/4" = 1'-0"12
2A-133A TR #221.21 - EAST VIEW
1/4" = 1'-0"13
2A-133A TR #221.21 - SOUTH VIEW
1/4" = 1'-0"14
2A-133A TR #221.21 - WEST VIEW
1/4" = 1'-0"16
2C-133A TR #221.22 - NORTH VIEW
1/4" = 1'-0"17
2C-133A TR #221.22 - EAST VIEW
1/4" = 1'-0"18
2C-133A TR #221.22 - SOUTH VIEW
1/4" = 1'-0"19
2C-133A TR #221.22 - WEST VIEW
Revisions: Date:
10% BASIS OF DESIGN 09/15/2022
35% SCHEMATIC DESIGN 11/17/2022
65% DESIGN DEVELOPMENT 02/24/2023
95% CONSTRUCTION DOCUMENTS 06/27/2023
100% CONSTRUCTION DOCUMENTS - FINAL
100% CONSTRUCTION
DOCUMENTS
07/28/2023
07/28/2023
RIC HELDT, AIA
08/28/2023
100% CONSTRUCTION DOCUMENTS - FINAL 08/28/2023
100% FINAL BID
DOCUMENTS100% FINAL BID DOCUMENTS 10/06/2023
10/06/2023
11/30/2023
UP
AP
NORTHPROJECT
NORTH
16' 12' 8' 4' 16' 32'
SCALE: 1/16" = 1'-0"
8' 24'00
ELEV
STAIR
CORR
TOILET
RECEIVING
LOBBY
HELP DESK
HAC
ELEV MACH RM
CORR
119A
MECH
FIRE
WORK ROOM
STAIR
VEST
VEST
COMPUTER RM
STOR
BATTERY RM
UPS ROOM
ROOM
ELEV LOBBY
IT
ROOM
ELEV
STAIR
STAIR
CONF
ELEC
STOR
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
227OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
229 LOUNGE
OFFICE
CORR
WOMENS
MENS
WAITING
CORR
OFFICE
CORR
OFFICE
OFFICES
CORR
OFFICES
CORR
VEST
HAC
CORR
OFFICES
MECH SHAFT
107F
IT
NORTHPROJECT
NORTH
16' 12' 8' 4' 16' 32'
SCALE: 1/16" = 1'-0"
8' 24'00
ELEV
STAIR
MECH SHAFT
107F
EQUIP
STORAGE
HVAC
STOR
CORR
107I
NORTHPROJECT
NORTH
16' 12' 8' 4' 16' 32'
SCALE: 1/16" = 1'-0"
8' 24'00
FLOOR PLAN LEGEND
CARD READER, REF TELECOM DRAWINGS
DATA PORT, REF TELECOM DRAWINGS
OUTLET, REF ELEC DRAWINGS
WIRELESS ACCESS POINT, REF TELECOM
DRAWINGS
ELEC PANEL, REF ELEC DRAWINGS
STRIP LIGHT FIXTURE, REF ELEC DRAWINGS
(E) FIRE EXTINGUISHER LOCATION
SEE 00-GI-002 - PROJECT GENERAL NOTES AND CODE SUMMARY
1. GENERAL PLAN NOTES
2. GENERAL DEMOLITION PLAN NOTES
3. GENERAL REFLECTED CEILING PLAN NOTES
PLAN NOTES: SEE GI-SHEETS
2x2 LIGHT FIXTURE
2x4 LIGHT FIXTURE
STRIP LIGHT FIXTURE
6" RECESSED CAN LIGHT FIXTURE
SUPPLY AIR DIFFUSER
RETURN AIR VENT
EXHAUST FAN
5/8" GYP. BOARD CEILING AFFIXED TO 3 5/8" MTL STUDS
2'x2' SUSPENDED ACOUSTIC CEILING TILE CEILING
RCP LEGEND
HATCH INDICATES AREA NOT IN SCOPE OF WORK
INDICATES BUILT ITEM TO BE REMOVED
INDICATES LIGHT FIXTURE TO BE REMOVED
DEMOLITION LEGEND
PROJECT KEY PLAN
CENTRAL TEXAS VETERANS HEALTH CARE SYSTEM
CTVHCS NETWORK #674
1901 VETERANS MEMORIAL DRIVE | TEMPLE, TEXAS 76504
NORTH
74746
A
B
D
C
A
C D
B
E W
EHRM ROOM ALLOCATION
SCALE: 1:80
80 80 1600
NORTHPROJECT
NORTH
SCALE: 1:80
80 80 1600
NORTHPROJECT
NORTH
SCALE: 1:80
80 80 1600
NORTHPROJECT
NORTH
U.S. Department of Veterans Affairs
VA FORM 08 - 6231
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
321 4 5 6 7 8 9 10
PROJECT NUMBER
BUILDING NUMBER
DRAWING NUMBER
PROJECT TITLE
LOCATION
ISSUE DATE CHECKED BY DRAWN BY
DRAWING TITLE
APPROVED:
PHASE
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
FLS
PROGRAM
CONTRACTING
ACTIVITY
CENTRAL (PCAC)
A u to d e s k D o c s /6
-2
-7
C
T V
H C
S
T e m p le
E H
R M
/2 B ld g r2
.r v t
-0
-2
:1
:3
AE-222-201
PLANS
A&E DESIGN
129 NORTH 29th STREET, SUITE 100
BILLINGS, MT 59101
PH: 406.248.2633
<To Be Determined>, AIA
GDM OF OREGON
1000 W STEUBEN ST, UNIT 3
BINGEN, WA 98605
PH: 541.224.8536
ADAM GOODIN, PE
EHRM INFRASTRUCTURE UPGRADE
TEMPLE, TEXAS
674-21-700
CHARLES R. YALE, R.A.
06/27/2023
95% CONSTRUCTION
DOCUMENTS
A/E:ARCHITECT:
FULLY SPRINKLERED
BUILDING 222
KEY COMMENT
1/16" = 1'-0"3
LEVEL 1 FLOOR PLAN
1/16" = 1'-0"8
LEVEL 2 FLOOR PLAN
1/16" = 1'-0"13
LEVEL 3 FLOOR PLAN
KEYNOTES
1" = 80'-0"1
LEVEL 1 FLOOR PLAN
1" = 80'-0"6
LEVEL 2 FLOOR PLAN
1" = 80'-0"11
LEVEL 3 FLOOR PLAN
Revisions: Date:
10% BASIS OF DESIGN 09/15/2022
35% SCHEMATIC DESIGN 11/17/2022
65% DESIGN DEVELOPMENT 02/24/2023
95% CONSTRUCTION DOCUMENTS 06/27/2023
100% CONSTRUCTION DOCUMENTS - FINAL
100% CONSTRUCTION
DOCUMENTS
07/28/2023
07/28/2023
RIC HELDT, AIA
08/28/2023
100% CONSTRUCTION DOCUMENTS - FINAL 08/28/2023
100% FINAL BID
DOCUMENTS100% FINAL BID DOCUMENTS 10/06/2023
10/06/2023
NOTE: SOME SYMBOLS SHOWN ON THIS LEGEND MAY NOT PERTAIN TO THIS PROJECT
M
BD
P
M
TS
SYMBOL DESCRIPTIONSYMBOL DESCRIPTIONSYMBOL DESCRIPTION SYMBOL DESCRIPTION
SYMBOL DESCRIPTIONSYMBOL DESCRIPTIONSYMBOL DESCRIPTION
SYMBOL DESCRIPTION
200A
RHC-1-1
AHU-1
VTU-1-1
-EXISTING FIRE DAMPER TO REMAIN
-EXISTING FIRE & SMOKE DAMPER TO REMAIN
-PACKAGED TERMINAL AIR CONDITIONER
(PTAC)
-HYDRONIC REHEAT COIL
-NEW FLAT OVAL DUCT
(WITH ACCESS PANEL)
(WITH ACCESS PANEL)
-ELECTRIC DUCT HEATER
(W/ PANEL CLEARANCE)
FM
-MANUAL BALANCING DAMPER
-AIR FLOW MEASURING STATION
-MOTOR OPERATED CONTROL DAMPER (MOD)
-FIRE & SMOKE DAMPER
-FIRE DAMPER
-FLEXIBLE CONNECTION
-ACCESS DOORS, VERTICAL OR HORIZONTAL
-INLINE CENTRIFUGAL FAN
-STAINLESS STEEL DUCTWORK
-DOOR GRILLE
-UNDERCUT DOOR
SA-1 -SOUND ATTENUATOR
-SPIN-IN TAKE-OFF
-DUCT ELBOW UP THROUGH ROOF OR SLAB ABOVE
-RECTANGLE-TO-ROUND TAKE-OFF
DNUP
-TRANSITION, SQUARE TO ROUND
UP W/IN FLOORDOWN
-CEILING EXHAUST
-CEILING RETURN
24x12
-STANDARD BRANCH TAKE-OFF
-RADIUS ELBOW
-TRANSITION, ECCENTRIC
-FLEXIBLE DUCT
-CHANGE OF ELEVATION
-DUCT ELBOW, NEGATIVE PRESSURE, RETURN
-DUCT ELBOW, EXHAUST
DIMENSION INDICATES SIDE TO WHICH ARROW IS POINTING
-DUCT ELBOW, POSITIVE PRESSURE (SUPPLY), FIRST
-NEW DUCTWORK, FIRST DIMENSION IS SIDE SHOWN
-TRANSITION, CONCENTRIC
-SQUARE THROAT ELBOW
W/TURNING VANES
-RECTANGULAR/ROUND BRANCH TAKE-OFF
OR ROUND/ROUND BRANCH TAKE-OFF
-SQUARE THROAT TEE
-RADIUS TEE
-ROUND DIFFUSER
-SUPPLY REGISTER OR GRILLE
-RETURN/EXHAUST REGISTER OR GRILLE
(VERTICAL MOUNT, SIDEWALL)
(VERTICAL MOUNT, SIDEWALL)
-EXISTING DUCTWORK TO REMAIN
-EXISTING DUCTWORK TO BE REMOVED
(CEILING DIFFUSERS ARE 4-WAY THROW UNO)
-CEILING DIFFUSER, ROUND NECK
-CEILING DIFFUSER, RECTANGULAR OR
SQUARE NECK (CEILING DIFFUSERS
ARE 4-WAY THROW UNO)
M-1
-TEMPERATURE SENSOR
-MOTORIZED CONTROL DAMPER
-HUMIDISTAT/HUMIDITY SENSOR
-THERMOSTAT/TEMPERATURE SENSOR
-REVISION REFERENCE
-DETAIL REFERENCE: TOP-DETAIL#,
BOTTOM-DRAWING# SHOWN ON
-PRESSURE SENSOR
-DUCT SMOKE DETECTOR
-CONNECT TO EXISTING
-DEMOLISH TO POINT INDICATED
FF -FINAL FILTERS
DDC -DIRECT DIGITAL CONTROLS
PRS -PRESSURE REDUCING STATION
SP -STATIC PRESSURE
-CFM (CUBIC FEET PER MINUTE)
P -CHANGE IN PRESSURE
CV -CONSTANT AIR VOLUME
-ROOFTOP AIR HANDLING UNITRTU
RS/L -REFRIGERANT SUCTION & LIQUID LINES
CL
-OUTSIDE AIR LOUVEROAL
-VARIABLE AIR VOLUMEVAV
-SUPPLY AIRSA
-ROOFTOP HEAT PUMPRHP
-REHEAT COILRHC
-REVOLUTIONS PER MINUTERPM
-RETURN AIRRA
-POLYVINYL CHLORIDE PIPEPVC
-PSI GAUGEPSIG
-POUNDS PER SQUARE INCHPSI
-PRESSURE REDUCING VALVEPRV
-OUTSIDE AIROA
-NOT TO SCALENTS
-NORMALLY OPENNO
-NORMALLY CLOSEDNC
-LINEAR DIFFUSERLD
-LEAVING WATER TEMPERATURELWT
-LEAVING AIR TEMPERATURELAT
-GALLONS PER MINUTEGPM
-FEET PER MINUTE
-FIRE DAMPER
-FAN COIL UNIT
-ENTERING WATER TEMPERATURE
-ENTERING AIR TEMPERATURE
-DOWN
-CONDENSING UNIT
-CUBIC FEET PER MINUTE
-CHANGE IN TEMPERATURE
-COOLING TOWER
-CEILING DIFFUSER
-CENTER LINE
-BRITISH THERMAL UNIT
-BRAKE HORSEPOWER
-BOTTOM OF PIPE
-ACCESS PANEL
-ABOVE FINISHED FLOOR
FPM
FD
FCU
EWT
EAT
DN
CU
CFM
T
CT
CD
BTU
BOP
BHP
AP
AFF
-AIR HANDLING UNITAHU
MBH -THOUSAND BTUs PER HOUR
AFD -ADJUSTABLE FREQUENCY DRIVE
ESP -EXTERNAL STATIC PRESSURE
KW -KILOWATT
MCA -MINIMUM CIRCUIT AMPS
MOCP -MAXIMUM OVER CURRENT PROTECTION
UNO
TSP -TOTAL STATIC PRESSURE
-VOLTS/PHASEV/PH
VFD -VARIABLE FREQUENCY DRIVE
-UNLESS NOTED OTHERWISE
FLA -FULL LOAD AMPS
-CONTROL VALVE
-45° PIPE RISE (R) / DROP (D)
-CONDENSER WATER SUPPLY
-CONDENSER WATER RETURN
-CHILLED WATER SUPPLY
-CHILLED WATER RETURN
-CONDENSATE
-HOT WATER RETURN
-HOT WATER SUPPLY
-REFRIGERANT LIQUID
-REFRIGERANT SUCTION
-VALVE ON RISER
-CAP
-CONNECTION, BOTTOM
-CONNECTION, TOP
-COUPLING
-ELBOW, 90°
-ELBOW, 45°
-ELBOW, TURNED DOWN
-ELBOW, TURNED UP
-TEE, OUTLET DOWN
-TEE, OUTLET UP
CWS
CWR
CHWS
CHWR
RL
RS
-FLOW SWITCH
-CHECK VALVE
-PSI REG.
-SOLENOID VALVE
-STRAINER
-GAS COCK
-BUTTERFLY VALVE
-CALIBRATING BALANCING VALVE
-BALL VALVE
-GATE VALVE
-UNION
PC -PUMPED CONDENSATE
DD
-HIGH PRESSURE STEAM SUPPLY
-LOW PRESSURE STEAM SUPPLY
-MEDIUM PRESSURE STEAM SUPPLY
CR -CONDENSATE RETURN
-SLOPE DIRECTION (DOWN)
-FLEX CONNECTION
-O.S.&Y. GATE VALVE
-THREE-WAY CONTROL VALVE
-THERMOMETER
- P-TRAP
-TWO-WAY CHECK VALVE
EQUIP.
-MANUAL VENT
-PRESSURE GAUGE
-RELIEF VALVE
-FLOW METER
-WATER METER
-INLINE PUMP
-INLINE PUMP
CTU - CONSTANT TERMINAL UNIT
VARIABLE/CONSTANT AIR VOLUME TERMINAL UNITS
VTU - VARIABLE TERMINAL UNIT
PTU - PARALLEL TERMINAL UNIT
STU - SERIES TERMINAL UNIT
-AIR HANDLING UNIT
-REHEAT COIL
-AIR DISTRIBUTION DEVICE
-NEGATIVE RELATIVE PRESSURE
-POSITIVE RELATIVE PRESSURE
-NEUTRAL RELATIVE PRESSURE
-HIGH PRESSURE STEAM RETURN
-LOW PRESSURE STEAM RETURN
-MEDIUM PRESSURE STEAM RETURN
-BACKDRAFT DAMPER
MOD -MOTOR OPERATED CONTROL DAMPER (MOD)
-PACKAGED TERMINAL AIR CONDITIONERPTAC
-PIPE ANCHORS
-CONCENTRIC REDUCER
-ECCENTRIC REDUCER
-STEAM TRAP
-FLOW DIRECTION
-SHEET NOTE CALLOUT
-SHEET NOTE CALLOUT
-SHEET NOTE CALLOUT
-EXHAUST DUCT UP THROUGH SLAB W/
-EXHAUST FAN ON ROOF W/ DUCT DOWN
THROUGH ROOF
-CEILING MOUNTED ACCESS DOOR
-RECTANGULAR DUCT SECTION UP, EXHAUST
-RECTANGULAR DUCT SECTION UP,
-RECTANGULAR DUCT SECTION UP, POSITIVE PRESSURE,
-ROUND DUCT SECTION UP
-FLAT OVAL DUCT SECTION UP
SUPPLY OR OUTSIDE AIR
NEGATIVE PRESSURE, RETURN
FAN ON ROOF ABOVE
-ABOVE FINISHED ROOFAFR
-TERMINAL UNIT, VARIABLE/CONSTANT AIR
VOLUME WITH ELECTRIC HEAT
-TERMINAL UNIT, VARIABLE/CONSTANT AIR
-TERMINAL UNIT, VARIABLE/CONSTANT AIR
VOLUME, FAN POWERED
VOLUME, FAN POWERED, WITH ELECTRIC
HEAT
-TERMINAL UNIT, VARIABLE/CONSTANT AIR
12x8Ø
HVAC GENERAL NOTESHVAC ABBREVIATIONSHVAC SYMBOL LEGEND
HVAC EQUIPMENT TAGSHVAC PIPING SYMBOL LEGEND
8"10x8
24x12
12x8
HPS
MPS
LPS
CD
HWR
HWS
HPR
MPR
LPR
H
VOLUME WITH ELECTRIC HEAT
1. CONNECTION TO EQUIPMENT SHALL BE VERIFIED WITH MANUFACTURER'S CERTIFIED DRAWINGS. TRANSITIONS TO ALL EQUIPMENT
SHALL BE VERIFIED AND PROVIDED FOR EQUIPMENT FURNISHED.
2. DIMENSIONS SHALL BE FIELD-VERIFIED AND COORDINATED PRIOR TO PROCUREMENT OR FABRICATION. COORDINATE THE WORK WITH OTHER TRADES INVOLVED. FIELD MODIFICATIONS SUCH AS OFFSETS IN PIPING OR DUCTWORK (INCLUDING DIVIDED DUCTWORK) NEEDED DUE TO OBSTRUCTIONS OR INTERFERENCES SHALL BE PROVIDED AT NO ADDITIONAL COST. FOR PROJECTS INVOLVING RENOVATION, COORDINATE NEW WORK WITH EXISTING ELEMENTS SUCH AS THE BUILDING STRUCTURE AND ARCHITECTURAL FEATURES, SPRINKLER PIPING, LIGHTS, PLUMBING, AND ELECTRICAL CONDUIT.
3. DUCT CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE LATEST EDITION OF THE SMACNA HVAC DUCT CONSTRUCTION
STANDARD.
4. SEE SPECIFICATIONS FOR GAUGES, THICKNESS, BRACING, REQUIREMENTS, ETC., OF DUCTWORK.
5. PROVIDE AIR TURNING VANES IN ALL 90 DEGREE RECTANGULAR DUCT ELBOWS.
6. DUCT SIZES AND ALL OPENINGS THROUGH BUILDING CONSTRUCTION SHALL SUIT EQUIPMENT FURNISHED.
7. COORDINATE DIFFUSER, GRILLE AND REGISTER LOCATIONS WITH ARCHITECTURAL REFLECTED CEILING PLANS AND EQUIPMENT OF
ALL TRADES.
8. LOCATE THERMOSTATS, TEMPERATURE SENSORS, HUMIDISTATS, AND HUMIDITY SENSORS AT 48" ABOVE FINISHED FLOOR UNLESS NOTED OTHERWISE. COORDINATE LOCATIONS WITH OTHER EQUIPMENT, FURNITURE, AND DOOR SWINGS.
9. ALL EQUIPMENT, DUCTWORK, ETC., SHALL BE SUPPORTED AS DETAILED AND/OR SPECIFIED. PROVIDE ADDITIONAL SUPPORTS AS
REQUIRED TO PROVIDE A VIBRATION-FREE, RIGID INSTALLATION.
10. ALL DUCT SIZES SHOWN ARE INSIDE CLEAR DIMENSIONS.
11. DAMPERS AND INSIDES OF DUCTS VISIBLE THROUGH GRILLES, REGISTERS AND DIFFUSERS SHALL BE PAINTED FLAT BLACK.
12. REFER TO TYPICAL DETAILS FOR PIPING AND INSTALLATION OF EQUIPMENT.
13. TRAPPED CONDENSATE DRAINS FROM ALL MECHANICAL EQUIPMENT SHALL BE PROVIDED FOR PROPER DRAINAGE TO SUIT
EQUIPMENT FURNISHED.
14. ACCESS PANELS IN DUCTWORK AND CEILINGS SHALL BE PROVIDED WHERE REQUIRED FOR OPERATION, BALANCING OR
MAINTENANCE OF ALL MECHANICAL EQUIPMENT.
15. ALL DUCTWORK AND PIPING IS SHOWN SCHEMATICALLY. PROVIDE ALL TRANSITIONS, TURNING VANES, ELBOWS, FITTINGS, ETC., TO ALLOW SMOOTH FLOWS. ALL SPLIT DUCT FITTINGS SHALL TRANSITION TO FULL SIZE OF THE SUM OF BOTH BRANCHES, UPSTREAM OF SPLIT.
16. PROVIDE CONCRETE HOUSEKEEPING PAD UNDER ALL FLOOR-MOUNTED EQUIPMENT. REFER TO SPECIFICATIONS FOR DETAILED
REQUIREMENTS.
17. VERIFY FINISH WITH ARCHITECT PRIOR TO PURCHASING GRILLES, REGISTERS, DIFFUSERS, LOUVERS AND OTHER AIR
DISTRIBUTION DEVICES.
18. PROVIDE FLEXIBLE DUCT CONNECTIONS ON ALL DUCTWORK CONNECTING TO EACH FAN, AIR HANDLING UNITS, AND FAN COIL
UNITS.
19. PROVIDE TRANSITIONS AT DIFFUSER NECKS AS REQUIRED TO MATCH SIZES OF FLEX DUCTS TO BE CONNECTED.
20. INTERRUPTIONS TO EXISTING SERVICES SHALL BE SCHEDULED FOR TIMES OTHER THAN NORMAL OPERATING HOURS (SUCH AS NIGHTS AND WEEKENDS). SUCH INTERRUPTIONS TO SERVICES SHALL NOT BE MADE WITHOUT THE PRIOR WRITTEN CONSENT OF THE OWNER'S REPRESENTATIVE AND PROPER COORDINATION WITH OTHER TRADES. PRE-WORK SHALL BE PERFORMED TO MAKE
THE SHUTDOWN PERIOD AS BRIEF AS POSSIBLE.
21. ALL EQUIPMENT, DUCTWORK, ETC., TO BE REMOVED SHALL REMAIN PROPERTY OF THE OWNER OR DISPOSED OF LEGALLY, AS
DIRECTED BY OWNER.
22. MAINTAIN CLEARANCE OF A MINIMUM OF 6" BETWEEN DUCTWORK, PIPING, EQUIPMENT, ETC., AND ALL FIRE RATED AND
FIRE/SMOKE RATED PARTITIONS, TO ALLOW FOR INSPECTIONS OF RATED WALLS.
23. LOCATE ALL OUTSIDE AIR INTAKES A MINIMUM OF 10' CLEAR FROM ALL PLUMBING VENTS AND EXHAUST AIR DISCHARGE
LOCATIONS.
24. DUCT RUNOUTS TO DIFFUSERS SHALL MATCH THE SIZE OF THE DIFFUSER NECK.
25. WATER PRESSURE DROPS THROUGH COIL CONTROL VALVES SHALL NOT EXCEED 5 PSI.
26. UNLESS OTHERWISE NOTED, ALL EQUIPMENT AND VALVE DRAINS SHALL BE INDEPENDENTLY PIPED FULL SIZE TO THE NEAREST
PLUMBING DRAIN.
27. SLEEVE AND SEAL ALL PIPING PENETRATIONS THROUGH BUILDING PARTITIONS. PROVIDE MANUAL AIR VENTS AT ALL HIGH POINTS
IN CHILLED WATER AND HOT WATER PIPING.
28. PIPING, DUCTWORK, LEAK PROTECTION APPARATUS, OR OTHER EQUIPMENT FOREIGN TO ELECTRICAL SWITCHBOARDS, PANELBOARDS, DISTRIBUTION BOARDS, OR MOTOR CONTROL CENTERS SHALL NOT BE INSTALLED WITHIN THE REQUIRED SPACE FOR WORKING CLEARANCES OR DEDICATED SPACES OF THE ELECTRICAL EQUIPMENT, EXTENDING IN FRONT OF AND FROM FLOOR TO STRUCTURAL CEILING WITH A WIDTH AND DEPTH OF THE ELECTRICAL EQUIPMENT IN ACCORDANCE WITH NEC-110.26.
24x12
24x12
S
MV
FM
M
T
UC
TAG
CFM
AHU NUMBER
AHU NUMBER COIL NUMBER
AHU NUMBER
TERMINAL NUMBER
TERMINAL UNIT TYPE
CFM
MECHANICAL DRAWING INDEX
SHEET DESCRIPTION
M-000-0-0-1 MECHANICAL SYMBOLS, LEGEND, NOTES AND INDEX
M-000-5-0-1 MECHANICAL DETAILS
M-000-7-0-1 MECHANICAL SCHEDULES
M-053-1-1-2 MECHANICAL LEVEL 01 FLOOR PLAN - BUILDING 53
M-146-1-1-1 MECHANICAL LEVEL 01 FLOOR PLAN - BUILDING 146
M-163-0-1-1 MECHANICAL BASEMENT FLOOR PLAN - BUILDING 163
M-163-1-1-1 MECHANICAL LEVEL 01 FLOOR PLAN - BUILDING 163
M-163-1-2-1 MECHANICAL LEVEL 02 FLOOR PLAN - BUILDING 163
M-163-1-3-1 MECHANICAL LEVEL 03 FLOOR PLAN - BUILDING 163
M-163-1-4-1 MECHANICAL LEVEL 04 FLOOR PLAN - BUILDING 163
M-163-1-5-1 MECHANICAL LEVEL 05 FLOOR PLAN - BUILDING 163
M-171-1-1-1 MECHANICAL LEVEL 01 FLOOR PLAN - BUILDING 171
M-202-1-1-1 MECHANICAL LEVEL 01 FLOOR PLAN - BUILDING 202 - WING A & B
M-202-1-1-3 MECHANICAL LEVEL 01 FLOOR PLAN - BUILDING 202 - WING E
M-202-1-2-1 MECHANICAL LEVEL 02 FLOOR PLAN - BUILDING 202 - WING A & B
M-202-1-2-2 MECHANICAL LEVEL 02 FLOOR PLAN - BUILDING 202 - WING C & D
M-204-1-0-1 MECHANICAL BASEMENT FLOOR PLAN - BUILDING 204
M-204-1-1-1 MECHANICAL LEVEL 01 FLOOR PLAN - BUILDING 204
M-204-1-2-1 MECHANICAL LEVEL 02 FLOOR PLAN - BUILDING 204
M-204-1-3-1 MECHANICAL LEVEL 03 FLOOR PLAN - BUILDING 204
M-204-1-4-1 MECHANICAL LEVEL 04 FLOOR PLAN - BUILDING 204
M-204-1-5-1 MECHANICAL LEVEL 05 FLOOR PLAN - BUILDING 204
M-204-1-6-1 MECHANICAL LEVEL 06 FLOOR PLAN - BUILDING 204
M-205-1-1-1 MECHANICAL LEVEL 01 FLOOR PLAN - BUILDING 205
M-205-1-2-1 MECHANICAL LEVEL 02 FLOOR PLAN - BUILDING 205
M-205-1-3-1 MECHANICAL LEVEL 03 FLOOR PLAN - BUILDING 205
M-221-1-1-1 MECHANICAL LEVEL 01 FLOOR PLAN - BUILDING 221
M-221-1-2-1 MECHANICAL LEVEL 02 FLOOR PLAN - BUILDING 221
1255 Corporate Dr, Suite 100 Irving, TX 75038 P 972.887.5555
©Copyright 2022
TLC No.:
www.tlc-engineers.com
F-004790
U.S. Department of Veterans Affairs
VA FORM 08 - 6231
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
321 4 5 6 7 8 9 10
PROJECT NUMBER
BUILDING NUMBER
DRAWING NUMBER
PROJECT TITLE
LOCATION
ISSUE DATE CHECKED BY DRAWN BY
DRAWING TITLE
APPROVED:
PHASE
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
FLS
PROGRAM
CONTRACTING
ACTIVITY
CENTRAL (PCAC)
122830 109145
BENJAMIN J. COLE
DESNECIL
A
R P
E E
S
ANOI
SS
E
F O
NI
G
NEL
S
R
O E
T A
T
X
ETF
A u to d e s k D o c s /6
-2 -7
C T
V H
C S
T e m p le
E H
R M
/2
M e c h
R
.r v t
/1 /2
:3
:2
P
M
M-000-0-0-1
MECHANICAL SYMBOLS, LEGEND,
NOTES AND INDEX
EHRM INFRASTRUCTURE UPGRADE
TEMPLE, TEXAS
674-21-700
AOBJC11/30/23
100% FINAL BID
DOCUMENTS
FULLY SPRINKLED
10/06/23Revisions: Date:
RA
SA
STEEL ROD W/THREADED
ENDS (TYP. 4 PLCS.)
REFRIGERANT PIPING
FILTER
FLOAT SWITCH
GALVANIZED SHEET METAL
SECONDARY DRAIN PAN TO
EXTEND 3" BEYOND UNIT ON ALL
SIDES BY 1-1/2" DEEP
P-TRAP CEILIING
ROUTE MAIN CONDENSATE
LINE TO PLUMBING COND.
SYSTEM. SEE PLUMBING
DRAWINGS FOR SIZE
FLEX CONN. (TYP.)
VIBRATION
ISOLATORS
SUPPORT FROM
STRUCTURE ABOVE
AS REQUIRED
AIR FLOW
NOTES:
1. PROVIDE (4 x DIA.) OF STRAIGHT PIPE ON BOTH SIDES OF BALANCING VALVE
2. ALL COMPONENTS FULL LINE SIZE UNLESS NOTED OTHERWISE
3. LOCATE UNIONS TO ALLOW FOR COIL PULL
SUPPLY
RETURN
PRESSURE GAUGE & COCK (TYP.)
MANUAL AIR VENT W/AUTO
SHUT-OFF COCK
COIL
FLEX. CONNECTION (TYP.)
THERMOMETER W/SEPARABLE WELL (TYP.)
UNION (TYP.)
STRAINER W / BLOWDOWN
P/T TEST PORTS
SHUT-OFF VALVE (TYP.)
TWO WAY CONTROL VALVE
AUTOMATIC FLOW
CONTROL DEVICE
PRESET BY MANUF. W/ P
& T TEST PORTS,
STRAINER, AND DRAIN.
(PRE-MANUF. SINGLE
ASSEMBLY ACCEPTABLE)
SIZES 4" UP TO 8" SIZES 8" AND ABOVE
SIZES UP TO 3"
ADJUSTABLE SWIVEL ROLLER
HANGER PIPE ROLL WITH
ADJUSTABLE SOCKETS
INSULATION
SEE SPECS FOR
ROD SIZES
PIPE HANGER
(SEE SPECS.)
CORNERS ARE
CLIPPED
FLARED END
FLARED EDGES
PIPE SADDLE HAS FLARED EDGES
NOTCHED TO FIT PIPE HANGER.
ALL INSULATION PASSES THRU
HANGER UNBROKEN
PIPE SADDLE
(TYP.)
INSULATION O.D.
LENGTH=TWICE
VERTICAL
OVERLAP
6" MAXIMUM
1/4" MINIMUM
DUCT
1" MINIMUM
(FOUR SIDES)
WALL
SLEEVE
SEE NOTE 2
D U
C T
C
O N
N E
C T
IO
N
S
S T
Y L E
A
S T
Y L E
B
MIN. CLEARANCE
S T
Y L E
C C
R
C O
. S E
E N
O T
E
SEE NOTE 3
SEE NOTE 1
DAMPER
SEE NOTE 2.
STYLE C, CR, & CO.
STYLE B
STYLE A
DUCT CONNECTIONS
(FOUR SIDES)
1" MINIMUM
6" MAXIMUM
OVERLAP
(SEE NOTE 1
SEE NOTE 2SLEEVE
(SEE NOTE 3
CONCRETE
FLOOR/CEILING
CONCRETE
FLOOR/CEILING
DAMPERHORIZONTAL
N.T.S.N.T.S.
NOTES
2 PROVIDE #10 BOLTS VERTICAL MOUNT (WALL)
GALVANIZED STEEL DAMPER (12") SPACING
DAMPER SLEEVE
DAMPER SLEEVE MUST BE MIN 26 GAUGE
UP TO MAXIMUM 10 GAUGE STEEL.
DAMPER ORIENTATION SHALL BE INSTALL WITH BLADES
WITHIN WALL OR FLOOR WHEN THEY ARE IN CLOSE
POSITION.
SEE NOTE 1
MOUNTING ANGLES MUST OVERLAP THE WALL MIN 1".1
GAUGE SHALL BE
IN ACCORDANCE WITH SMACNA & MANUFACTURER'S RECOMMENDATION
SUPPORT FROM STRUCTURE
ABOVE
ABOVE
SUPPORT FROM STRUCTURE
SPACING.
RIGID DUCT10'-0" MAXIMUM
SUPPORT STRAP
1" WIDE 18 GA. 2" WIDE SUPPORT
STRAP 3'-0"
MAXIMUM SPACING
FLEXIBLE DUCT
CONSTRUCTION STANDARDS.
SECTION IV SMACNA HVAC DUCT
SHALL COMPLY WITH REQUIREMENTS OF
NESS) AND MAXIMUM HANGER SPACING
NOTE: STRAP HANGER SIZE (WIDTH x THICK-60" MAX
HANGER
STRAPS
SUPPORT FROM
STRUCTURE
ABOVE (TYP)
SCREWS
SCREWS MAY BE
OMITTED IF HANGER LOOPS
1" MIN
STRAP HANGER - ROUND DUCT
CHILLED WATER COOLING COIL.
THE SPACE IS SERVED BY DEDICATED AIR HANDLING UNIT WITH CHILLED WATER COOLING COIL.
FAN SHALL OPERATE UPON A CALL FOR COOLING BASED ON SPACE TEMPERATURE OR HUMIDITY.
ON A RISE IN SPACE TEMPERATURE AS MEASURED BY THE SPACE TEMPERATURE SENSOR, COOLING COIL CONTROL VALVE WILL MODULATE
COOLING VALVE OPEN TO MAINTAIN COOLING SET POINT.
ON A DROP IN SPACE TEMPERATURE AS MEASURED BY THE SPACE TEMPERATURE SENSOR, COOLING COIL CONTROL VALVE WILL MODULATE
COOLING VALVE CLOSED TO MAINTAIN COOLING SET POINT.
ON A RISE IN SPACE HUMIDITY AS MEASURED BY THE SPACE HUMIDITY SENSOR, COOLING COIL CONTROL VALVE WILL MODULATE TO DECREASE HUMIDITY TO SET POINT. ONCE HUMIDITY REACHES SET POINT, COOLING COIL CONTROL REVERTS TO CONTROL VIA TEMPERATURE.
BAS SHALL MONITOR AIRFLOW, TEMPERATURE, AIRFLOW AND HUMIDITY.
PROVIDE A HIGH WATER LEVEL ALARM IN DRAIN PAN OF UNIT. WHEN HIGH WATER IS SENSED BY THE SENSOR, THE BAS SHALL BE ALARMED.
UNIT WILL MAINTAIN OPERATION
DX COOLING COIL.
THE SPACE IS SERVED BY DEDICATED AIR HANDLING UNIT WITH DX COOLING COIL.
FAN SHALL OPERATE UPON A CALL FOR COOLING BASED ON SPACE TEMPERATURE OR HUMIDITY.
ON A RISE IN SPACE TEMPERATURE AS MEASURED BY THE SPACE TEMPERATURE SENSOR, DX COOLING COIL SHALL OPERATE IN FULL COOL
TO MAINTAIN COOLING SET POINT.
ON A DROP IN SPACE TEMPERATURE AS MEASURED BY THE SPACE TEMPERATURE SENSOR, DX COOLING COIL SHALL DISENGAGE MAINTAIN
SET POINT.
ON A RISE IN SPACE HUMIDITY AS MEASURED BY THE SPACE HUMIDITY SENSOR, COOLING COIL WILL ACTIVATE AT FULL COOL TO DECREASE HUMIDITY TO SET POINT. ONCE HUMIDITY REACHES SET POINT, COOLING COIL CONTROL REVERTS TO CONTROL VIA TEMPERATURE.
BAS SHALL MONITOR AIRFLOW, TEMPERATURE, AIRFLOW AND HUMIDITY.
PROVIDE A HIGH WATER LEVEL ALARM IN DRAIN PAN OF UNIT. WHEN HIGH WATER IS SENSED BY THE SENSOR, THE BAS SHALL BE ALARMED.
UNIT WILL MAINTAIN OPERATION.
No Scale
SUSPENDED FCU/AHU INSTALLATION 1No Scale
2-WAY COIL PIPING DIAGRAM 2No Scale
INSULATED PIPE HANGER 3
No Scale 5
FIRE DAMPER INSTALLATION DETAILS (FLD)
No Scale
TYPICAL DUCT SUPPORT 6
No Scale
TYPICAL SIDEWALL GRILLE 4
1255 Corporate Dr, Suite 100 Irving, TX 75038 P 972.887.5555
©Copyright 2022
TLC No.:
www.tlc-engineers.com
F-004790
U.S. Department of Veterans Affairs
VA FORM 08 - 6231
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
321 4 5 6 7 8 9 10
PROJECT NUMBER
BUILDING NUMBER
DRAWING NUMBER
PROJECT TITLE
LOCATION
ISSUE DATE CHECKED BY DRAWN BY
DRAWING TITLE
APPROVED:
PHASE
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
FLS
PROGRAM
CONTRACTING
ACTIVITY
CENTRAL (PCAC)
122830 109145
BENJAMIN J. COLE
DESNECIL
A
R P
E E
S
ANOI
SS
E
F O
NI
G
NEL
S
R
O E
T A
T
X
ETF
A u to d e s k D o c s /6
-2 -7
C T
V H
C S
T e m p le
E H
R M
/2
M e c h
R
.r v t
/1 /2
:3
:3
P
M
M-000-5-0-1
MECHANICAL DETAILS
EHRM INFRASTRUCTURE UPGRADE
TEMPLE, TEXAS
674-21-700
NBGC11/30/23
100% FINAL BID
DOCUMENTS
FULLY SPRINKLED
10/06/23Revisions: Date:
No Scale
SEQUENCES OF OPERATION 7
A 0 600 18x10 SIDEWALL SUPPLY DIFFUSER
(SIZED @ NC < 20)
BASIS OF DESIGN: TITUS 300RS-HD
COLOR: SELECTED BY ARCHITECT
MATERIAL: STEEL
OPPOSED BLADE DAMPERS: YES
DOUBLE DEFLECTION
B
AIR DISTRIBUTION SCHEDULE
MARK
CFM
NECK SIZE DESCRIPTION
MIN MAX
FACE SIZE
LENGTH
SIDEWALL RETURN DIFFUSER
BASIS OF DESIGN: TITUS 355FL
COLOR: SELECTED BY ARCHITECT
MATERIAL: STEEL
OPPOSED BLADE DAMPERS: YES
0 DEGREE DEFLECTION
800 18x12
0 600
601 800
18x10
18x12
18x10
18x12
18x10
18x12
24x16 24x16801 1400
24x14 24x14801 1400
1255 Corporate Dr, Suite 100 Irving, TX 75038 P 972.887.5555
©Copyright 2022
TLC No.:
www.tlc-engineers.com
F-004790
U.S. Department of Veterans Affairs
VA FORM 08 - 6231
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
321 4 5 6 7 8 9 10
PROJECT NUMBER
BUILDING NUMBER
DRAWING NUMBER
PROJECT TITLE
LOCATION
ISSUE DATE CHECKED BY DRAWN BY
DRAWING TITLE
APPROVED:
PHASE
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
FLS
PROGRAM
CONTRACTING
ACTIVITY
CENTRAL (PCAC)
122830 109145
BENJAMIN J. COLE
DESNECIL
A
R P
E E
S
ANOI
SS
E
F O
NI
G
NEL
S
R
O E
T A
T
X
ETF
A u to d e s k D o c s /6
-2 -7
C T
V H
C S
T e m p le
E H
R M
/2
M e c h
R
.r v t
/1 /2
:3
:3
P
M
M-000-7-0-1
MECHANICAL SCHEDULES
EHRM INFRASTRUCTURE UPGRADE
TEMPLE, TEXAS
674-21-700
AuthorChecker11/30/23
100% FINAL BID
DOCUMENTS
FULLY SPRINKLED
10/06/23
PLAN
MARK
BASIS OF DESIGN AIRFLOW FAN DATA COOLING COIL DATA
SEER EER
ELECTRICAL
WEIGHT
(LBS)
OUTDOOR
UNITMFGR
COIL
MODEL
Supply Airflow
EXT.
SP
(IN.
WG)
MOTOR
HP
EAT LAT
CAPA
CITY
MCA MOP VOLTS PHASEDB WB DB WB
SEN.
BTU/H
FCU-146-1 CARRIER AC018BNHDCH/AA 535 CFM 0.5 0.2 80 67 55 55 18,000 20.5 11.5 1.21 15 208 1 80 CU-146-1
FCU-171-1 CARRIER AC024BNHDCH/AA 635 CFM 0.5 0.2 80 67 55 55 24,000 20.5 11.7 1.56 30 208 1 80 CU-171-1
FCU-171-2 CARRIER AC024BNHDCH/AA 635 CFM 0.5 0.2 80 67 55 55 24,000 20.5 11.7 1.56 30 208 1 80 CU-171-2
SPLIT SYSTEM CONDENSING UNIT SCHEDULE
PLAN
MARK MFGR MODEL
NOMINAL
TONS
AMBIENT AIR
TEMP ºF REFRIG. MCA MOCP VOLTS PHASE WEIGHT
CU-146-1 CARRIER AC018BXADCH/AA 1.5 105 R-410A 13.5 28 A 208 1 90
CU-171-1 CARRIER AC024BXADCH/AA 2 105 R-410A 24.1 26 A 208 1 160
CU-171-2 CARRIER AC024BXADCH/AA 2 105 R-410A 24.1 26 A 208 1 160
CHILLED WATER AHU
MARK MANUFACTURER MODEL
PRIMARY
AIRFLOW FAN COOLING COIL
TOTAL
COOLING
CAPACITY
UNIT
WEIGHT
ELECTRICAL ELECTRICAL
SUPPLY
CFM
PRESS AIRSIDE WATERSIDE
MCA MOCP VOLT PHESP
EAT(
db)
LAT
(db) ROWS EWT LWT GPM
FCU-163-1 CARRIER 42DCA08BRAY6AYB7 800 CFM 0.50 in-wg 80 °F 55 °F 4 45 °F 55 °F 4.8 24000.0 Btu/h 110 lb 8 A 15 A 115 V 1
FCU-163-2 CARRIER 42DCD014 1400 CFM 0.50 in-wg 80 °F 55 °F 4 45 °F 55 °F 4.8 36800.0 Btu/h 110 lb 8 A 15 A 115 V 1
FCU-163-3 CARRIER 42DC06BRAY6AYB7 600 CFM 0.50 in-wg 80 °F 55 °F 4 45 °F 55 °F 4.8 18000.0 Btu/h 110 lb 8 A 15 A 115 V 1
FCU-163-4 CARRIER 42DCD014 1400 CFM 0.50 in-wg 80 °F 55 °F 4 45 °F 55 °F 4.8 36800.0 Btu/h 110 lb 8 A 15 A 115 V 1
FCU-163-5 CARRIER 42DCD014 1400 CFM 0.50 in-wg 80 °F 55 °F 4 45 °F 55 °F 4.8 36800.0 Btu/h 110 lb 8 A 15 A 115 V 1
FCU-163-6 CARRIER 42DCA08BRAY6AYB7 800 CFM 0.50 in-wg 80 °F 55 °F 4 45 °F 55 °F 4.8 24000.0 Btu/h 110 lb 8 A 15 A 115 V 1
FCU-163-7 CARRIER 42DCA08BRAY6AYB7 800 CFM 0.50 in-wg 80 °F 55 °F 4 45 °F 55 °F 4.8 24000.0 Btu/h 110 lb 8 A 15 A 115 V 1
FCU-163-8 CARRIER 42DCA08BRAY6AYB7 800 CFM 0.50 in-wg 80 °F 55 °F 4 45 °F 55 °F 4.8 24000.0 Btu/h 110 lb 8 A 15 A 115 V 1
FCU-163-9 CARRIER 42DCA08BRAY6AYB7 800 CFM 0.50 in-wg 80 °F 55 °F 4 45 °F 55 °F 4.8 24000.0 Btu/h 110 lb 8 A 15 A 115 V 1
FCU-163-10 CARRIER 42DCA08BRAY6AYB7 800 CFM 0.50 in-wg 80 °F 55 °F 4 45 °F 55 °F 4.8 24000.0 Btu/h 110 lb 8 A 15 A 115 V 1
FCU-163-11 CARRIER 42DCA08BRAY6AYB7 800 CFM 0.50 in-wg 80 °F 55 °F 4 45 °F 55 °F 4.8 24000.0 Btu/h 110 lb 8 A 15 A 115 V 1
FCU-163-12 CARRIER 42DCD014 1400 CFM 0.50 in-wg 80 °F 55 °F 4 45 °F 55 °F 4.8 36800.0 Btu/h 110 lb 8 A 15 A 115 V 1
FCU-163-13 CARRIER 42DCA08BRAY6AYB7 800 CFM 0.50 in-wg 80 °F 55 °F 4 45 °F 55 °F 4.8 24000.0 Btu/h 110 lb 8 A 15 A 115 V 1
FCU-163-14 CARRIER 42DCA08BRAY6AYB7 800 CFM 0.50 in-wg 80 °F 55 °F 4 45 °F 55 °F 4.8 24000.0 Btu/h 110 lb 8 A 15 A 115 V 1
FCU-202-1 CARRIER 42DCA08BRAY6AYB7 800 CFM 0.50 in-wg 80 °F 55 °F 4 45 °F 55 °F 4.8 24000.0 Btu/h 110 lb 8 A 15 A 115 V 1
FCU-202-2 CARRIER 42DCA08BRAY6AYB7 800 CFM 0.50 in-wg 80 °F 55 °F 4 45 °F 55 °F 4.8 24000.0 Btu/h 110 lb 8 A 15 A 115 V 1
FCU-202-3 CARRIER 42DCA08BRAY6AYB7 800 CFM 0.50 in-wg 80 °F 55 °F 4 45 °F 55 °F 4.8 24000.0 Btu/h 110 lb 8 A 15 A 115 V 1
FCU-202-3 CARRIER 42DCA08BRAY6AYB7 800 CFM 0.50 in-wg 80 °F 55 °F 4 45 °F 55 °F 4.8 24000.0 Btu/h 110 lb 8 A 15 A 115 V 1
FCU-202-4 CARRIER 42DCA08BRAY6AYB7 800 CFM 0.50 in-wg 80 °F 55 °F 4 45 °F 55 °F 4.8 24000.0 Btu/h 110 lb 8 A 15 A 115 V 1
FCU-202-5 CARRIER 42DC06BRAY6AYB7 600 CFM 0.50 in-wg 80 °F 55 °F 4 45 °F 55 °F 4.8 18000.0 Btu/h 110 lb 8 A 15 A 115 V 1
FCU-204-1 CARRIER 42DCA08BRAY6AYB7 800 CFM 0.50 in-wg 80 °F 55 °F 4 45 °F 55 °F 4.8 24000.0 Btu/h 110 lb 8 A 15 A 115 V 1
FCU-204-2 CARRIER 42DCA08BRAY6AYB7 800 CFM 0.50 in-wg 80 °F 55 °F 4 45 °F 55 °F 4.8 24000.0 Btu/h 110 lb 8 A 15 A 115 V 1
FCU-204-3 CARRIER 42DC06BRAY6AYB7 600 CFM 0.50 in-wg 80 °F 55 °F 4 45 °F 55 °F 4.8 18000.0 Btu/h 110 lb 8 A 15 A 115 V 1
FCU-204-4 CARRIER 42DCA08BRAY6AYB7 800 CFM 0.50 in-wg 80 °F 55 °F 4 45 °F 55 °F 4.8 24000.0 Btu/h 110 lb 8 A 15 A 115 V 1
FCU-204-5 CARRIER 42DCA08BRAY6AYB7 800 CFM 0.50 in-wg 80 °F 55 °F 4 45 °F 55 °F 4.8 24000.0 Btu/h 110 lb 8 A 15 A 115 V 1
FCU-204-6 CARRIER 42DCA08BRAY6AYB7 800 CFM 0.50 in-wg 80 °F 55 °F 4 45 °F 55 °F 4.8 24000.0 Btu/h 110 lb 8 A 15 A 115 V 1
FCU-204-7 CARRIER 42DCA08BRAY6AYB7 800 CFM 0.50 in-wg 80 °F 55 °F 4 45 °F 55 °F 4.8 24000.0 Btu/h 110 lb 8 A 15 A 115 V 1
FCU-204-8 CARRIER 42DCA08BRAY6AYB7 800 CFM 0.50 in-wg 80 °F 55 °F 4 45 °F 55 °F 4.8 24000.0 Btu/h 110 lb 8 A 15 A 115 V 1
FCU-204-9 CARRIER 42DCA08BRAY6AYB7 800 CFM 0.50 in-wg 80 °F 55 °F 4 45 °F 55 °F 4.8 24000.0 Btu/h 110 lb 8 A 15 A 115 V 1
FCU-204-10 CARRIER 42DC06BRAY6AYB7 600 CFM 0.50 in-wg 80 °F 55 °F 4 45 °F 55 °F 4.8 24000.0 Btu/h 110 lb 8 A 15 A 115 V 1
FCU-204-11 CARRIER 42DCA08BRAY6AYB7 800 CFM 0.50 in-wg 80 °F 55 °F 4 45 °F 55 °F 4.8 24000.0 Btu/h 110 lb 8 A 15 A 115 V 1
FCU-204-12 CARRIER 42DCA08BRAY6AYB7 800 CFM 0.50 in-wg 80 °F 55 °F 4 45 °F 55 °F 4.8 24000.0 Btu/h 110 lb 8 A 15 A 115 V 1
FCU-204-13 CARRIER 42DCA08BRAY6AYB7 800 CFM 0.50 in-wg 80 °F 55 °F 4 45 °F 55 °F 4.8 24000.0 Btu/h 110 lb 8 A 15 A 115 V 1
FCU-205-1 CARRIER 42DC06BRAY6AYB7 600 CFM 0.50 in-wg 80 °F 55 °F 4 45 °F 55 °F 4.8 18000.0 Btu/h 110 lb 8 A 15 A 115 V 1
FCU-205-2 CARRIER 42DCA08BRAY6AYB7 800 CFM 0.50 in-wg 80 °F 55 °F 4 45 °F 55 °F 4.8 24000.0 Btu/h 110 lb 8 A 15 A 115 V 1
FCU-205-3 CARRIER 42DCA08BRAY6AYB7 800 CFM 0.50 in-wg 80 °F 55 °F 4 45 °F 55 °F 4.8 24000.0 Btu/h 110 lb 8 A 15 A 115 V 1
FCU-221-1 CARRIER 42DC06BRAY6AYB7 600 CFM 0.50 in-wg 80 °F 55 °F 4 45 °F 55 °F 4.8 18000.0 Btu/h 110 lb 8 A 15 A 115 V 1
FCU-221-2 CARRIER 42DC06BRAY6AYB7 600 CFM 0.50 in-wg 80 °F 55 °F 4 45 °F 55 °F 4.8 18000.0 Btu/h 110 lb 8 A 15 A 115 V 1
FCU-221-3 CARRIER 42DC06BRAY6AYB7 600 CFM 0.50 in-wg 80 °F 55 °F 4 45 °F 55 °F 4.8 18000.0 Btu/h 110 lb 8 A 15 A 115 V 1
FCU-221-4 CARRIER 42DC06BRAY6AYB7 600 CFM 0.50 in-wg 80 °F 55 °F 4 45 °F 55 °F 4.8 18000.0 Btu/h 110 lb 8 A 15 A 115 V 1
Revisions: Date:
53-1
53-2
53-3
53-4
53-5
53-A53-B53-C53-D53-E53-F53-G53-H53-J53-K53-L53-M53-N53-O53-P53-Q53-R
F
V
W W
W W
D N
S C
I
S C
I
R VP
R VP
R VP
R VP
R PPR
R PPR
R PPR
R PPR
GOL
A&M
DC S
ADO 004
ADR 001
R 00
GSA DIR
C AR
POOL 43
C AR
POOL 62
C AR
POOL 64
C AR
POOL 40
C AR
POOL 41
C AR
POOL 65
C AR
POOL 44
C AR
POOL 53
C AR
POOL 55
R 002
U C
U C
E S
P O
L
IC
E
E S
E S
POLIC E
POLIC E
POLIC E
POLIC E
POLIC E
POLIC E
EEO
EEO
R PPR 116
R P
P
R P
P
R P
P
H B
P C
H B
P C
H B
P C
H B
P C
R P
P
A F
G E
A F
G E
A F
G E
A F
G E
R P
P
R
P P
R P
P
C O
L
LE
G E
A U
S T
IN
A U
S T
IN
B R
O W
N W
O O
D
K
IL
LE
E
N
S T
E P
H E
N V
I L
L E
S T
A
TI
O N
C E
D A
R P
A R
K
B R
O W
N W
O O
D
P A
L I
S T
I N
E
L O
T A
T O
T A
L S
P A
C E
S
241 TOTAL SPACES
166 TOTAL SPACES
M S
M S
M S
M S
M S
M S
M S
M S
M S
M S
M S
M S
M S
M S
M S
M S
M S
M S
HB PC
HB PC
R PP
R PP
19 19 20
52 52
RPP 5
RPP 4
RPP 3
RPP 2
RPP 1
V
IS
IT
O
R
V
IS
IT
O
R
H BP
C
H BP
C
H BP
C
H BP
C
H BP
C
H BP
C
H BP
C
H BP
C
H BP
C
H BP
C
H BP
C
H BP
C
H BP
C
H BP
C
H BP
C
H BP
C
H BP
C
H BP
C
H BP
C
H BP
C
H BP
C
H BP
C
22 16
54 TOTAL SPACES
73 TOTAL SPACES
P AT IE NT
ONL Y
P AT IE NT
ONL Y
T O
T A
L S
P A
C E
S
G S
A
G S
A
L O
G
48 TOTAL SPACES
LOT C = 230 SPACES
S P
A C
E S
T
OTA
L S
PA
C
ES
94 TOTAL SPACES
VP
VP
VP
VP
VP
VP
VP
VP
VP
VPGSA
GSA
P O
L
IC
E
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
DPO
DPO
DPO
DPO
DPO
DPO
DPO
DPO
DPO
DPO
DPO
13 SPACESLOT G = 4 80 TOTAL SPACES
62 61
P AT IE NT
ONL Y
MC MC
SS2
SS1
M S
M S
M S
M S
M S
M S
M S
M S
M S M S
M S
M S
M S
M S
G S
F G
S F
G S
F G
S F
1428169
49 56 53
LOT B = 260 SPACES
LOT F = 3 07 TOTAL SPACES
L O
T E
S P
A C
E S
ROAD 1D
ROAD 3A
86.29
UC
21056
69.69
UT1
69.66
UT
86.28UT
7310 6 83.51
UF
73126 84.64
UF
71716
84.41 GL
48636 73.99
W D
48646 73.81
W D
48746 73.89
W D
4875 6 73.53W
D
48766 73.67
W D
48776 73.59
W D
48786 73.56
W D
73.51 W
D
48806 73.70
W D
48816 73.64
W D
4882 6 73.61
W D
75.73 W
M H
84.81 W
M H
76.36 W
M H
STATE
PROPERTY
STATE
PROPERTY
S20°43'57"W 1881.53'
S19°03'31"W 1018.87'
219.11'
N °0 '5
.6
N16°49'17"E 1793.20'N17°05'43"E 888.50'
N16°58'42"E
ESMT #16
ESMT #17
E S
M T
ESMT #14
E S
M T
ESMT #8
E S
M T
E S
M T
ESM
T #
ESMT #3
ESMT #4
E S
M T
ESMT #3
E S
M T
ESMT #1
(CALLED 20.03
AC)3983/232
N °0 '0
.9
CALLED 72.61 ACRES
1018/717
EUGENIA TERRACE ADDITION
VOL. 241, PG. 564,
BELL COUNTY DEED RECORDS
PARK HEIGHTS ADDITION
TO THE CITY OF TEMPLE
VOL. 406, PG. 232
BELL COUNTY DEED RECORDS
3983/232
3983/232
/2
/2
/2
/2
3983/232
3/2
3983/232
3983/232
3983/232
3983/232
3983/232
/23
/2
56.70'
S17°58'17"W 687.60
S °0 '4
E
.8
N17°58'17"E 505.54L4 L3
L2
L
L
L
L
N °0 '4
.2
U P
T-164
T E
A G
U E
P L
A C
E
TEAGUE
PLACE
ROAD
R O
A D
B
R O
A D
A
W A
V E
R
TEAGUE
PLACE
R O
A D
ROAD
R O
A D
ROAD
9A
R O
A D
ROAD
4A
R O
A D
ROAD
ROAD
3A
ROAD
2A
ROAD
ROAD
ROAD
R O
A D
T E
A G
U E
P L
A C
E
FLAG
MEMORIAL
RAILROAD
TRACKS
TEAGUE
PLACE
TEAGUE
PLACE
T E
A G
U E
P L
A C
E
T E
A G
U E
P L
A C
E
TEAGUE
PLACE
TEAGUE
PLACE
R O
A D
R O
A D
RO
A
D
ROAD
R O
A D
B
R O
A D
A
ROAD
1C
R O
A D
A
R O
A D
B
ROAD
3A
ROAD
5A
R O
A D
B
ROAD
5B
R O
A D
C
R O
A D
ROAD
10A
R O
A D
B
W A
V E
U
ROAD
3A2
SA
FE
T Y
B L
D G
TEAGUE
TOWER
BLDG 163
STATE
VETERANS
HOME
TEAGUE
HOSPITAL
BLDG 204
CUP
CVI
D O
M
IC
IL
IA
R Y
B
LD
G
T
CT
T161T162
W AR E H O USE
B L DG
20 6
T163
IRRIGATION
WELL
HOUSE
FISH
HOUSE
N O
P A
R K
IN
G
BUILDING
CLC
W
P
A S
53 ENG.
SHOPS
M.K. & T.R.R.
VETERAN MEMORIAL
DRIVE
T-164A
A B
C D
B L
D G
EMERGENCY
DEPARTMENT
CTVHS
BUSINESS OFFICE
BLDG 171
E
E
N G
U N
D E
R
U
N D
E R
C O
N S T
R U
C T
IO
N
M
E N
T A
L H
E A
L T
H
MOTOR POOL
A
B
D
CE
BOILER
PLANT
K
CAR WASH
CHAPEL
PET/CT
M R
I
M
165 167
T-500
LAKE
HOUSE
PAVILION
T-257
LAKE HOUSE
RESTR OOMS
E
L
O G
E
E
M S
L
A U
N D
R Y
C O
N S
T R
U C
T
IO
N
W
U N
D E
R C
O N
S T
R U
C T
IO
N
W
E
R E
C
T H
E R
A P
Y
W
O C
C
H E
A L
T H
U N
D E
R C
O N
S T
R U
C T
IO
N
NEW PARKING
GARAGE
(UNDER
CONSTRUCTION)
T TT
FUEL
TANKS
B O
IL
E
R U
N
IT
S A
N D
G E
N E
R A
T O
R S
V
ENT
V
ENT
D IESELTA
NK
FDC
V E
N T
V
ENT
V
ENT
D U
M P
S T
E R
LOADING
DOCK
LOADING
DOCK
FDC
R ADIO
TOW ER
G
VENT
VENT
R ADIO
ANTENNA
LOADING
DOCK
VENT VENT
VENT
B ASKETBALL
C OURT
VENTVENT
V E
N T
VENT
V E
N T
V E
N T
V E
N T
V E
N T
V E
N T
VENTVENT
VENT
VENT VENT
V E
N T
VENT
V E
N
TVENT
LOADING
DOCK
VENT
VENT
AC
VENT
K
BM NORTH EAST
CORNER OF HEL IPAD
ELEVATION: 67 9 .7 5 '
B R
A
SS
M O
N
F N
D
/2
I.
R
MON 60
B R
A
SS
M O
N
F N
D
/8
I.
R
FND. 5/8" I.R.
FN
D. 5
/8 " I
.R
F N
D
/8
I.
R
S
°0
'0
W
.9
F N
D
/8
I.
R
T
T
T
T
T
T
T
T
T T T
T
T
T
T
T
T
T
T
T T
T T
TT
9 '' 107.9994
1255 Corporate Dr, Suite 100 Irving, TX 75038 P 972.887.5555
©Copyright 2022
TLC No.:
www.tlc-engineers.com
F-004790
U.S. Department of Veterans Affairs
VA FORM 08 - 6231
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
321 4 5 6 7 8 9 10
PROJECT NUMBER
BUILDING NUMBER
DRAWING NUMBER
PROJECT TITLE
LOCATION
ISSUE DATE CHECKED BY DRAWN BY
DRAWING TITLE
APPROVED:
PHASE
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
FLS
PROGRAM
CONTRACTING
ACTIVITY
CENTRAL (PCAC)
122830
C D
A B
D
C
A
B
F E
109145
BENJAMIN J. COLE
DESNECIL
A
R P
E E
S
ANOI
SS
E
F O
NI
G
NEL
S
R
O E
T A
T
X
ETF
A u to d e s k D o c s /6
-2 -7
C T
V H
C S
T e m p le
E H
R M
/2
M e c h
R
.r v t
/1 /2
:3
:3
P
M
M-053-1-1-2
MECHANICAL LEVEL 01 FLOOR
PLAN - BUILDING 53
EHRM INFRASTRUCTURE UPGRADE
TEMPLE, TEXAS
674-21-700
AuthorChecker11/30/23
100% FINAL BID
DOCUMENTS
FULLY SPRINKLED
BUILDING 53
10/06/23
1/8" = 1'-0"1
LEVEL 1 BUILDING 53
KEYNOTES:
EXISTING HVAC SYSTEMS TO REMAIN IN CURRENT LOCATION.
EXISTING HVAC SYSTEMS TO BE REMOVED FROM THIS AREA.
PROVIDE NEW DX 1.5-TON DEDICATED FAN COIL UNIT FOR ROOM. UNIT SHALL BE
LOCATED OUTSIDE OF ROOM AND DUCTED INTO THE NEW IT ROOM. REFER TO
SCHEDULE FOR UNIT INFORMATION.
CORR
C-2
202-A 202-B 202-C 202-D 202-E 202-F 202-G 202-H 202-J 202-K 202-L M N O P Q R
FCU-146-1
CU-146-1
M-146-1-1-1
II.2I.6
202-J
12x12 RA x1
S
A
FCU-146-1
T
A 600
B 600
H
1/8" = 1'-0"1
LEVEL 1 BUILDING 146
KEYNOTES:
EXISTING HVAC SYSTEMS TO REMAIN IN CURRENT LOCATION.
EXISTING HVAC SYSTEMS TO BE REMOVED FROM THIS AREA.
PROVIDE NEW DX 2-TON DEDICATED FAN COIL UNIT FOR ROOM. UNIT SHALL BE
LOCATED OUTSIDE OF ROOF AND DUCTED INTO THE NEW IT ROOM. REFER TO
SCHEDULE FOR UNIT INFORMATION.
F
V
W W
W W
D N
S C
I
S C
I
R VP
R VP
R VP
R VP
R PPR
R PPR
R PPR
R PPR
GOL
A&M
DC S
ADO 004
ADR 001
R 00
GSA DIR
C AR
POOL 43
C AR
POOL 62
C AR
POOL 64
C AR
POOL 40
C AR
POOL 41
C AR
POOL 65
C AR
POOL 44
C AR
POOL 53
C AR
POOL 55
R 002
U C
U C
E S
P O
L
IC
E
E S
E S
POLIC E
POLIC E
POLIC E
POLIC E
POLIC E
POLIC E
EEO
EEO
R PPR 116
R P
P
R P
P
R P
P
H B
P C
H B
P C
H B
P C
H B
P C
R P
P
A F
G E
A F
G E
A F
G E
A F
G E
R P
P
R
P P
R P
P
C O
L
LE
G E
A U
S T
IN
A U
S T
IN
B R
O W
N W
O O
D
K
IL
LE
E
N
S T
E P
H E
N V
I L
L E
S T
A
TI
O N
C E
D A
R P
A R
K
B R
O W
N W
O O
D
P A
L I
S T
I N
E
L O
T A
T O
T A
L S
P A
C E
S
241 TOTAL SPACES
166 TOTAL SPACES
M S
M S
M S
M S
M S
M S
M S
M S
M S
M S
M S
M S
M S
M S
M S
M S
M S
M S
HB PC
HB PC
R PP
R PP
19 19 20
52 52
RPP 5
RPP 4
RPP 3
RPP 2
RPP 1
V
IS
IT
O
R
V
IS
IT
O
R
H BP
C
H BP
C
H BP
C
H BP
C
H BP
C
H BP
C
H BP
C
H BP
C
H BP
C
H BP
C
H BP
C
H BP
C
H BP
C
H BP
C
H BP
C
H BP
C
H BP
C
H BP
C
H BP
C
H BP
C
H BP
C
H BP
C
22 16
54 TOTAL SPACES
73 TOTAL SPACES
P AT IE NT
ONL Y
P AT IE NT
ONL Y
T O
T A
L S
P A
C E
S
G S
A
G S
A
L O
G
48 TOTAL SPACES
LOT C = 230 SPACES
S P
A C
E S
T
OTA
L S
PA
C
ES
94 TOTAL SPACES
VP
VP
VP
VP
VP
VP
VP
VP
VP
VPGSA
GSA
P O
L
IC
E
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
DPO
DPO
DPO
DPO
DPO
DPO
DPO
DPO
DPO
DPO
DPO
13 SPACESLOT G = 4 80 TOTAL SPACES
62 61
P AT IE NT
ONL Y
MC MC
SS2
SS1
M S
M S
M S
M S
M S
M S
M S
M S
M S M S
M S
M S
M S
M S
G S
F G
S F
G S
F G
S F
1428169
49 56 53
LOT B = 260 SPACES
LOT F = 3 07 TOTAL SPACES
L O
T E
S P
A C
E S
ROAD 1D
ROAD 3A
86.29
UC
21056
69.69
UT1
69.66
UT
86.28UT
7310 6 83.51
UF
73126 84.64
UF
71716
84.41 GL
48636 73.99
W D
48646 73.81
W D
48746 73.89
W D
4875 6 73.53W
D
48766 73.67
W D
48776 73.59
W D
48786 73.56
W D
73.51 W
D
48806 73.70
W D
48816 73.64
W D
4882 6 73.61
W D
75.73 W
M H
84.81 W
M H
76.36 W
M H
STATE
PROPERTY
STATE
PROPERTY
S20°43'57"W 1881.53'
S19°03'31"W 1018.87'
219.11'
N °0 '5
.6
N16°49'17"E 1793.20'N17°05'43"E 888.50'
N16°58'42"E
ESM T #16
ESMT #17
E S
M T
ESMT #14
E S
M T
ESMT #8
E S
M T
E S
M T
ESM
T #
ESMT #3
ESMT #4
E S
M T
ESMT #3
E S
M T
ESMT #1
(CALLED 20.03
AC)3983/232
N °0 '0
.9
CALLED 72.61 ACRES
1018/717
EUGENIA TERRACE ADDITION
VOL. 241, PG. 564,
BELL COUNTY DEED RECORDS
PARK HEIGHTS ADDITION
TO THE CITY OF TEMPLE
VOL. 406, PG. 232
BELL COUNTY DEED RECORDS
3983/232
3983/232
/2
/2
/2
/2
3983/232
3/2
3983/232
3983/232
3983/232
3983/232
3983/232
/23
/2
56.70'
S17°58'17"W 687.60
S °0 '4
.8
N17°58'17"E 505.54L4 L3
L2
L
L
L
L
N °0 '4
.2
U P
T-164
T E
A G
U E
P L
A C
E
TEAGUE
PLACE
ROAD
R O
A D
B
R O
A D
A
W A
V E
R
TEAGUE
PLACE
R O
A D
ROAD
R O
A D
ROAD
9A
R O
A D
ROAD
4A
R O
A D
ROAD
ROAD
3A
ROAD
2A
ROAD
ROAD
ROAD
R O
A D
T E
A G
U E
P L
A C
E
FLAG
MEMORIAL
RAILROAD
TRACKS
TEAGUE
PLACE
TEAGUE
PLACE
T E
A G
U E
P L
A C
E
T E
A G
U E
P L
A C
E
TEAGUE
PLACE
TEAGUE
PLACE
R O
A D
R O
A D
RO
A
D
ROAD
R O
A D
B
R O
A D
A
ROAD
1C
R O
A D
A
R O
A D
B
ROAD
3A
ROAD
5A
R O
A D
B
ROAD
5B
R O
A D
C
R O
A D
ROAD
10A
R O
A D
B
W A
V E
U
ROAD
3A2
SA
FE
T Y
B L
D G
TEAGUE
TOWER
BLDG 163
STATE
VETERANS
HOME
TEAGUE
HOSPITAL
BLDG 204
CUP
CVI
D O
M
IC
IL
IA
R Y
B
LD
G
T
CT
T161T162
W AR E H O USE
B L DG
20 6
T163
IRRIGATION
WELL
HOUSE
FISH
HOUSE
N O
P A
R K
IN
G
BUILDING
CLC
W
P
A S
53 ENG.
SHOPS
M.K. & T.R.R.
VETERAN MEMORIAL
DRIVE
T-164A
A B
C D
B L
D G
EMERGENCY
DEPARTMENT
CTVHS
BUSINESS OFFICE
BLDG 171
E
E
N G
U N
D E
R
U
N D
E R
C O
N S T
R U
C T
IO
N
M
E N
T A
L H
E A
L T
H
MOTOR POOL
A
B
D
CE
BOILER
PLANT
K
CAR WASH
CHAPEL
PET/CT
M R
I
M
165 167
T-500
LAKE
HOUSE
PAVILION
T-257
LAKE HOUSE
RESTR OOMS
E
L
O G
E
E
M S
L
A U
N D
R Y
C O
N S
T R
U C
T
IO
N
W
U N
D E
R C
O N
S T
R U
C T
IO
N
W
E
R E
C
T H
E R
A P
Y
W
O C
C
H E
A L
T H
U N
D E
R C
O N
S T
R U
C T
IO
N
NEW PARKING
GARAGE
(UNDER
CONSTRUCTION)
T TT
FUEL
TANKS
B O
IL
E
R U
N
IT
S A
N D
G E
N E
R A
T O
R S
V
ENT
V
ENT
D IESELTA
NK
FDC
V E
N T
V
ENT
V
ENT
D U
M P
S T
E R
LOADING
DOCK
LOADING
DOCK
FDC
R ADIO
TOW ER
G
VENT
VENT
R ADIO
ANTENNA
LOADING
DOCK
VENT VENT
VENT
B ASKETBALL
C OURT
VENTVENT
V E
N T
VENT
V E
N T
V E
N T
V E
N T
V E
N T
V E
N T
VENTVENT
VENT
VENT VENT
V E
N T
VENT
V E
N
TVENT
LOADING
DOCK
VENT
VENT
AC
VENT
K
BM NORTH EAST
CORNER OF HEL IPAD
ELEVATION: 67 9 .7 5 '
B R
A
SS
M O
N
F N
D
/2
I.
R
MON 60
B R
A
SS
M O
N
F N
D
/8
I.
R
FND. 5/8" I.R.
FN
D. 5
/8 " I
.R
F N
D
/8
I.
R
S
°0
'0
W
.9
F N
D
/8
I.
R
T
T
T
T
T
T
T
T
T T T
T
T
T
T
T
T
T
T
T T
T T
TT
9 '' 107.9994
1255 Corporate Dr, Suite 100 Irving, TX 75038 P 972.887.5555
©Copyright 2022
TLC No.:
www.tlc-engineers.com
F-004790
U.S. Department of Veterans Affairs
VA FORM 08 - 6231
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
321 4 5 6 7 8 9 10
PROJECT NUMBER
BUILDING NUMBER
DRAWING NUMBER
PROJECT TITLE
LOCATION
ISSUE DATE CHECKED BY DRAWN BY
DRAWING TITLE
APPROVED:
PHASE
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
FLS
PROGRAM
CONTRACTING
ACTIVITY
CENTRAL (PCAC)
122830
C D
A B
D
C
A
B
F E
109145
BENJAMIN J. COLE
DESNECIL
A
R P
E E
S
ANOI
SS
E
F O
NI
G
NEL
S
R
O E
T A
T
X
ETF
A u to d e s k D o c s /6
-2 -7
C T
V H
C S
T e m p le
E H
R M
/2
M e c h
R
.r v t
/1 /2
:3
:3
P
M
M-146-1-1-1
MECHANICAL LEVEL 01 FLOOR
PLAN - BUILDING 146
EHRM INFRASTRUCTURE UPGRADE
TEMPLE, TEXAS
674-21-700
NBGC11/30/23
100% FINAL BID
DOCUMENTS
FULLY SPRINKLED
BUILDING 146
10/06/23
1/4" = 1'-0"
LEVEL 1 BUILDING 146 - TR 146.11
UP
UP
UP
DN
DN
DN
DN
UP
DN
UP
DN
DN
DN
DN
F E
C
M-163-0-1-1
2 316 3-
B B
0A
.1
FCU-163-1
T
1"CHWS
1"CHWR
FCU-163-12
1 1/2"CHWR
1 1/2"CHWS
1 1/2"CHWR
1 1/2"CHWS
1 1/2"CHWS
1 1/2"CHWR
1"CHWR1"CHWS
1 1/2"CHWS
1 1/2"CHWR
1"CHWS 1"CHWR
1"CHWR
1"CHWS
1 1/2"CHWR 1 1/2"CHWS
M-163-0-1-1
M-163-0-1-1 bH b7
A 800
B 800
T
1"CHWS
1"CHWR
14x12 SA x1
R
A
FCU-163-1
H b2
A 800
B 800
FCU-163-1314x14 RA x1
R
A
14x12 SA
1"CHWS 1"CHWR
T
H bF
14x14 RA x1
R
A x1
S
A
FCU-163-14
B 800 A 800
T
H
1/16" = 1'-0"1
BASEMENT BUILDING 163
KEYNOTES:
EXISTING HVAC SYSTEMS TO REMAIN IN CURRENT LOCATION.
EXISTING HVAC SYSTEMS TO BE REMOVED FROM THIS AREA.
PROVIDE NEW CHILLED WATER 2-TON DEDICATED FAN COIL UNIT FOR ROOM.
UNIT SHALL BE LOCATED OUTSIDE OF ROOF AND DUCTED INTO THE NEW IT
ROOM. REFER TO SCHEDULE FOR UNIT INFORMATION.
ROUTE AND CONNECT NEW 1-1/4" CWS AND 1-1/4"CWR TO MAIN CHILLED WATER
LINE IN ROOM MECH BD111.
EXISTING SANITARY LINE AND EXISTING DUCTWORK TO BE REROUTED FOR NEW
TELECOM ROOM.
EXISTING COLD WATER LINE TO BE ROUTED TOWARDS THE OUTSIDE.
F
V
W W
W W
D N
S C
I
S C
I
R VP
R VP
R VP
R VP
R PPR
R PPR
R PPR
R PPR
GOL
A&M
DC S
ADO 004
ADR 001
R 00
GSA DIR
C AR
POOL 43
C AR
POOL 62
C AR
POOL 64
C AR
POOL 40
C AR
POOL 41
C AR
POOL 65
C AR
POOL 44
C AR
POOL 53
C AR
POOL 55
R 002
U C
U C
E S
P O
L
IC
E
E S
E S
POLIC E
POLIC E
POLIC E
POLIC E
POLIC E
POLIC E
EEO
EEO
R PPR 116
R P
P
R P
P
R P
P
H B
P C
H B
P C
H B
P C
H B
P C
R P
P
A F
G E
A F
G E
A F
G E
A F
G E
R P
P
R
P P
R P
P
C O
L
LE
G E
A U
S T
IN
A U
S T
IN
B R
O W
N W
O O
D
K
IL
LE
E
N
S T
E P
H E
N V
I L
L E
S T
A
TI
O N
C E
D A
R P
A R
K
B R
O W
N W
O O
D
P A
L I
S T
I N
E
L O
T A
T O
T A
L S
P A
C E
S
241 TOTAL SPACES
166 TOTAL SPACES
M S
M S
M S
M S
M S
M S
M S
M S
M S
M S
M S
M S
M S
M S
M S
M S
M S
M S
HB PC
HB PC
R PP
R PP
19 19 20
52 52
RPP 5
RPP 4
RPP 3
RPP 2
RPP 1
V
IS
IT
O
R
V
IS
IT
O
R
H BP
C
H BP
C
H BP
C
H BP
C
H BP
C
H BP
C
H BP
C
H BP
C
H BP
C
H BP
C
H BP
C
H BP
C
H BP
C
H BP
C
H BP
C
H BP
C
H BP
C
H BP
C
H BP
C
H BP
C
H BP
C
H BP
C
22 16
54 TOTAL SPACES
73 TOTAL SPACES
P AT IE NT
ONL Y
P AT IE NT
ONL Y
T O
T A
L S
P A
C E
S
G S
A
G S
A
L O
G
48 TOTAL SPACES
LOT C = 230 SPACES
S P
A C
E S
T
OTA
L S
PA
C
ES
94 TOTAL SPACES
VP
VP
VP
VP
VP
VP
VP
VP
VP
VPGSA
GSA
P O
L
IC
E
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
D P
O
DPO
DPO
DPO
DPO
DPO
DPO
DPO
DPO
DPO
DPO
DPO
13 SPACESLOT G = 4 80 TOTAL SPACES
62 61
P AT IE NT
ONL Y
MC MC
SS2
SS1
M S
M S
M S
M S
M S
M S
M S
M S
M S M S
M S
M S
M S
M S
G S
F G
S F
G S
F G
S F
1428169
49 56 53
LOT B = 260 SPACES
LOT F = 3 07 TOTAL SPACES
L O
T E
S P
A C
E S
ROAD 1D
ROAD 3A
86.29
UC
21056
69.69
UT1
69.66
UT
86.28UT
7310 6 83.51
UF
73126 84.64
UF
71716
84.41 GL
48636 73.99
W D
48646 73.81
W D
48746 73.89
W D
4875 6 73.53W
D
48766 73.67
W D
48776 73.59
W D
48786 73.56
W D
73.51 W
D
48806 73.70
W D
48816 73.64
W D
4882 6 73.61
W D
75.73 W
M H
84.81 W
M H
76.36 W
M H
STATE
PROPERTY
STATE
PROPERTY
S20°43'57"W 1881.53'
S19°03'31"W 1018.87'
219.11'
N °0 '5
.6
N16°49'17"E 1793.20'N17°05'43"E 888.50'
N16°58'42"E
ESM T #16
ESMT #17
E S
M T
ESMT #14
E S
M T
ESMT #8
E S
M T
E S
M T
ESM
T #
ESMT #3
ESMT #4
E S
M T
ESMT #3
E S
M T
ESMT #1
(CALLED 20.03
AC)3983/232
N °0 '0
.9
CALLED 72.61 ACRES
1018/717
EUGENIA TERRACE ADDITION
VOL. 241, PG. 564,
BELL COUNTY DEED RECORDS
PARK HEIGHTS ADDITION
TO THE CITY OF TEMPLE
VOL. 406, PG. 232
BELL COUNTY DEED RECORDS
3983/232
3983/232
/2
/2
/2
/2
3983/232
3/2
3983/232
3983/232
3983/232
3983/232
3983/232
/23
/2
56.70'
S17°58'17"W 687.60
S °0 '4
.8
N17°58'17"E 505.54L4 L3
L2
L
L
L
L
N °0 '4
.2
U P
T-164
T E
A G
U E
P L
A C
E
TEAGUE
PLACE
ROAD
R O
A D
B
R O
A D
A
W A
V E
R
TEAGUE
PLACE
R O
A D
ROAD
R O
A D
ROAD
9A
R O
A D
ROAD
4A
R O
A D
ROAD
ROAD
3A
ROAD
2A
ROAD
ROAD
ROAD
R O
A D
T E
A G
U E
P L
A C
E
FLAG
MEMORIAL
RAILROAD
TRACKS
TEAGUE
PLACE
TEAGUE
PLACE
T E
A G
U E
P L
A C
E
T E
A G
U E
P L
A C
E
TEAGUE
PLACE
TEAGUE
PLACE
R O
A D
R O
A D
RO
A
D
ROAD
R O
A D
B
R O
A D
A
ROAD
1C
R O
A D
A
R O
A D
B
ROAD
3A
ROAD
5A
R O
A D
B
ROAD
5B
R O
A D
C
R O
A D
ROAD
10A
R O
A D
B
W A
V E
U
ROAD
3A2
SA
FE
T Y
B L
D G
TEAGUE
TOWER
BLDG 163
STATE
VETERANS
HOME
TEAGUE
HOSPITAL
BLDG 204
CUP
CVI
D O
M
IC
IL
IA
R Y
B
LD
G
T
CT
T161T162
W AR E H O USE
B L DG
20 6
T163
IRRIGATION
WELL
HOUSE
FISH
HOUSE
N O
P A
R K
IN
G
BUILDING
CLC
W
P
A S
53 ENG.
SHOPS
M.K. & T.R.R.
VETERAN MEMORIAL
DRIVE
T-164A
A B
C D
B L
D G
EMERGENCY
DEPARTMENT
CTVHS
BUSINESS OFFICE
BLDG 171
E
E
N G
U N
D E
R
U
N D
E R
C O
N S T
R U
C T
IO
N
M
E N
T A
L H
E A
L T
H
MOTOR POOL
A
B
D
CE
BOILER
PLANT
K
CAR WASH
CHAPEL
PET/CT
M R
I
M
165 167
T-500
LAKE
HOUSE
PAVILION
T-257
LAKE HOUSE
RESTR OOMS
E
L
O G
E
E
M S
L
A U
N D
R Y
C O
N S
T R
U C
T
IO
N
W
U N
D E
R C
O N
S T
R U
C T
IO
N
W
E
R E
C
T H
E R
A P
Y
W
O C
C
H E
A L
T H
U N
D E
R C
O N
S T
R U
C T
IO
N
NEW PARKING
GARAGE
(UNDER
CONSTRUCTION)
T TT
FUEL
TANKS
B O
IL
E
R U
N
IT
S A
N D
G E
N E
R A
T O
R S
V
ENT
V
ENT
D IESELTA
NK
FDC
V E
N T
V
ENT
V
ENT
D U
M P
S T
E R
LOADING
DOCK
LOADING
DOCK
FDC
R ADIO
TOW ER
G
VENT
VENT
R ADIO
ANTENNA
LOADING
DOCK
VENT VENT
VENT
B ASKETBALL
C OURT
VENTVENT
V E
N T
VENT
V E
N T
V E
N T
V E
N T
V E
N T
V E
N T
VENTVENT
VENT
VENT VENT
V E
N T
VENT
V E
N
TVENT
LOADING
DOCK
VENT
VENT
AC
VENT
K
BM NORTH EAST
CORNER OF HEL IPAD
ELEVATION: 67 9 .7 5 '
B R
A
SS
M O
N
F N
D
/2
I.
R
MON 60
B R
A
SS
M O
N
F N
D
/8
I.
R
FND. 5/8" I.R.
FN
D. 5
/8 " I
.R
F N
D
/8
I.
R
S
°0
'0
W
.9
F N
D
/8
I.
R
T
T
T
T
T
T
T
T
T T T
T
T
T
T
T
T
T
T
T T
T T
TT
9 '' 107.9994
1255 Corporate Dr, Suite 100 Irving, TX 75038 P 972.887.5555
©Copyright 2022
TLC No.:
www.tlc-engineers.com
F-004790
U.S. Department of Veterans Affairs
VA FORM 08 - 6231
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
321 4 5 6 7 8 9 10
PROJECT NUMBER
BUILDING NUMBER
DRAWING NUMBER
PROJECT TITLE
LOCATION
ISSUE DATE CHECKED BY DRAWN BY
DRAWING TITLE
APPROVED:
PHASE
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
FLS
PROGRAM
CONTRACTING
ACTIVITY
CENTRAL (PCAC)
122830
C D
A B
D
C
A
B
F E
109145
BENJAMIN J. COLE
DESNECIL
A
R P
E E
S
ANOI
SS
E
F O
NI
G
NEL
S
R
O E
T A
T
X
ETF
A u to d e s k D o c s /6
-2 -7
C T
V H
C S
T e m p le
E H
R M
/2
M e c h
R
.r v t
/1 /2
:3
:4
P
M
M-163-0-1-1
MECHANICAL BASEMENT FLOOR
PLAN - BUILDING 163
EHRM INFRASTRUCTURE UPGRADE
TEMPLE, TEXAS
674-21-700
NBGC11/30/23
100% FINAL BID
DOCUMENTS
FULLY SPRINKLED
BUILDING 163
10/06/23
1/4" = 1'-0"
BUILDING 163 - BASEMENT - TR 163.01
Revisions: Date:
1/4" = 1'-0"3
BASEMENT BUILDING 163 - EXISTING TR 145
1/4" = 1'-0"
BASEMENT BUILDING 163 - EXISTING TR 83
DN
DN
DN
DN
DN
DN
UP
UP
UP
UP
UP
UP
UP
UP
DN
UP
DN
DN
M-163-1-1-1
M-163-1-1-1
M-163-1-1-1
M-163-1-1-1
2 3
2 3
2 3
2 3
TR #163.14
1D112
TR #163.11
1A127
TR #163.12
1B176
CYTOLOGY
1D108C
CHIEF P&LM SVC
1D124A
TB/MYCOLOGY
IMMUNOLOGY
1D101A
STAIR 7
1S7
LABORATORY
ADMINISTRATION
1D124
PROCESSING
1D108A
MICROBIOLOGY
1D105
HISTOLOGY
1D108
BIOLOGICAL SAFETY
1D101B
FLUOR MICROSCOPE
1D101C
PREPARATION
1D101
HEATLTH SYSTEMS
SPECIALIST
1D123SLIDE & BLOCK FILES
1D109
MED GAS
1D100 MICROBIOLOGIST
1D106
SUPERVISORS OFFICE
1D103
LABORATORY INFORMATION
1D122
SUPERVISORS OFFICE
1D121
MOTHER FRIENDLY ROOM
1C41
STAIR 6
1S6 CORR
1D
CORR
1K PROFESSIONAL CONF RM
1D120
STAFF PATHOLOGIST
1D110
LABORATORY INFORMATION
1D122A
STAFF PATHOLOGIST
1D119
UNISEX
1D107 WOMEN
1D111
CORR
S-10
CORR
S-11
STOR
1D104AHEMATOLOGY
1D102
IDF
1D114
HAC
1D118
CORR
S-12 MECH
1D127
ELEC
1D116
HAC
1C29 LAB CONFERENCE
1D117
SPECIAL CHEMISTRY
1D104B
STAFF PATHOLOGIST
1D113
CHEMISTRY OFFICE
1D104C
LABORATORY OPERATIONS
1D115
WC
1A126A
WC
1A118
ELEC
1A121A
MEN
1A129
ULTRASOUND
1A126
CHIEF TECHNOLOGIST
1A130A
TELE
1B172
WOMEN
1A128
AMPHITHEATRE OFFICE
1B150B
ADMIN OFFICE
1A123
RADIOGRAPHIC RM
1A117
PROGRAM SPECIALIST
1A123A
STOR
1A119
CORR
S-13
STAIR 3
1S3
MECH
1B165
IT TRAINING RM
1B154A
IDF
1B171
CORR
1B164 OFFICE
1A121
LABORATORY
1B160
STOR
1B164B
CORR
1A
WC
1A115A
PROJECTION RM
1B150C
MAIN AMPHITHEATRE
1B150
CHIEF IMAGING SERVICE
1A130
CORR
S-14
RADIOGRAPHIC ULTRA
SOUND
1A115
IT SUPPORT RM
1B154D
ANCILLARY TESTING
COORDINATOR
1B169
WOMEN
1B166
WC
1B164A ULTRASOUND
1A124B
ULTRASOUND
1A124A
SPECIMAN COLLECTION
1C36
RADIOGRAPHIC
FLUOROSCOPY
1A114
IT SUPPORT RM
1B154C
WORKROOM
1A120
STOR
1B163
STAFF RADIOLOGIST
1A131
BREAKROOM
1B158
STOR
1B150A
S-UTILITY
1A122
ASST CHIEF TECHNOLOGIST
1A113
BLOOD BANK
1B156
HAC
1A134
HAC
1B168
MEN
1B167
ELEC
1B152
IDF
1B151 DRESSING ROOM
1A112B
WC
1A112D
S…