36C26319B0002-0004002.pdf

PDF 1 MB Posted

Attached to
636-803 Expand Specialty Care Addition VAICHCS, Iowa City, IA
Solicitation number
36C26319B0002
Issued by

About this file

36C26319B0002 0004 50-P03 - PLUMBING PLANS LOWER LEVEL (1 page).pdf

View the file

Other files

File Type Posted
36C26319C0132-000.docx DOCX document
36C26319B0002-0005001.pdf PDF
36C26319B0002-0005000.docx DOCX document
36C26319B0002-0004001.pdf PDF
36C26319B0002-0004000.docx DOCX document
36C26319B0002-0003005.pdf PDF
36C26319B0002-0003004.pdf PDF
36C26319B0002-0003001.pdf PDF
36C26319B0002-0003006.pdf PDF
36C26319B0002-0003000.docx DOCX document
36C26319B0002-0003007.pdf PDF
36C26319B0002-0003003.pdf PDF
36C26319B0002-0003002.pdf PDF
36C26319B0002-0003008.pdf PDF
36C26319B0002-0002001.pdf PDF
36C26319B0002-0002000.docx DOCX document
36C26319B0002-0001003.pdf PDF
36C26319B0002-0001001.pdf PDF
36C26319B0002-0001002.pdf PDF
36C26319B0002-0001004.pdf PDF
36C26319B0002-0001000.docx DOCX document
36C26319B0002-007.docx DOCX document
36C26319B0002-008.pdf PDF
36C26319B0002-009.pdf PDF
36C26319B0002-010.pdf PDF
36C26319B0002-013.pdf PDF
36C26319B0002-014.pdf PDF
36C26319B0002-011.pdf PDF
36C26319B0002-012.pdf PDF
36C26319B0002-000.docx DOCX document
Show all 30

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

UP

50-P03

2.8 3

D.7

E

4" FDT

2" V UP

SEE DETAIL

2/50-P03

4" SAN UP

SEE DETAIL

2/50-P03

4" UP TO

4" FCO

50-P03

2 2.8 3 4 4.5

DD

D.7D.7

EE

4" UP TO P-101

3" UP TO FD-C

2" UP TO P-408

2" UP TO P-408

2" V

4" SAN DOWN

SEE DETAIL 1/50-P03

2" V DOWN

SEE DETAIL 1/50-P03

FD-E

50-WH-1

50-WH-2

ET-1

PAD-011-B05

3/4" CW

RPZ-3

CW TO MECHANICAL

MAKEUP WATER

BASE BIDE + ALTERNATE NOTES .

A. BID ITEM 1 - CONTRACTOR SHALL PROVIDE TOOLS, MATERIALS AND LABOR NECESSARY

FOR COMPLETION OF CONSTRUCTION PROJECT #636-803 “CONSTRUCT SPECIALTY

CLINICS ADDITION” AT THE IOWA CITY VA HEALTHCARE SYSTEM, IN IOWA CITY, IOWA

AND IN ACCORDANCE WITH THE DRAWINGS AND SPECIFICATIONS.

B. ALTERNATE 1 – ALL WORK OF BID ITEM NO. 1, LESS THE WORK TO PROVIDE AND

INSTALL CERTAIN ITEMS OR SYSTEMS, AS FOLLOWS.

1. ELIMINATE ALL THE MECHANICAL WORK SHOWN IN THE LOWER LEVEL:

DOMESTIC WATER HEATER WH-2, HYDRONIC HEATING PUMP 50-HWP-B2,

HYDRONIC HEAT EXCHANGER 50-HX-B2, DEMOLITION OF STEAM PIPING AND

ASSOCIATED NEW PIPING.

C. ALTERNATE 2 - ALL WORK OF BID ITEM 1, LESS THE WORK DELETED IN ALTERNATE 1,

AND LESS THE WORK TO PROVIDE AND INSTALL CERTAIN ITEMS OR SYSTEMS, AS

FOLLOWS.

1. ELIMINATE MEN’S TOILETS 120 AND 220, AND WOMEN’S TOILETS 121 AND 122B: AT

ROOMS 122 AND 122 LEAVE SINGLE SPACE IN EXISTING FINISHED CONDITION. AT

ROOMS 222 AND 222 PROVIDE SINGLE ROOM WITH MECHANICAL, PLUMBING, FIRE

PROTECTION AS SHOWN FOR THIS BID ITEM 1 ON THE DRAWINGS.

2. ELIMINATE FINISHES FOR EXAM 116, 118, 132, 134, & 136. LEAVE SPACES IN

EXISTING FINISHED CONDITION.

3. ELIMINATE FINISHES FOR EXAM 216, 218, 232, 234, & 236. PROVIDE SINGLE ROOM

FOR EACH GROUP OF ROOMS. INSTALL MECHANICAL, FIRE PROTECTION AS

SHOWN FOR THE BASE BID. STUB PLUMBING INTO ROOM.

F

LO

O R

, S E

E P

LU

M

B

IN

G D

R A

W

IN

G S

[3 m m

[1 m m

CONTROL VALVE BY

MANUFACTURER OF

DOMESTIC WATER HEATER

FLOAT &

THERMOSTATIC

TRAP ASSEMBLY

GRAVITY STEAM

CONDENSATE

RETURN

DIELECTRIC

FITTING

SCALE POCKET

DOMESTIC WATER HEATER

TRAP OR ORIFICED UNION FITTING FURNISHED BY

MANUFACTURER OF DOMESTIC WATER HEATER, SEE

PLUMBING DWGS.

FLOOR

NOTES:

1. VERTICAL COIL TYPE DOMESTIC WATER HEATER IS SHOWN. IF HORIZONTAL TUBE BUNDLE

TYPE IS FURNISHED, PIPING SHALL BE SIMILAR.

2. SEE PLUMBING DRAWINGS FOR PIPING CONNECTIONS.

3. PIPING TO UPPER HEATER HEAD SHOULD BE PROVIDED WITH UNION OR FLANGES,

LOCATED OUTSIDE THE OUTER DIAMETER OF HEAD TO FACILITATE REMOVAL OF HEAD AND

SHELL.

4. PIPING BETWEEN CONTROL VALVE AND HEATER CONNECTION SHOULD BE AS SHORT AS

POSSIBLE.

5. PROVIDE INTEGRAL OR EXTERNAL HEAT TRAPS.

6. PROVIDE HOSE CONNECTION TO DRAIN.

D H

W

DCW

DHWR

DRAIN

TEMPERATURE & PRESSURE RELIEF VALVE

BY MANUFACTURER OF DOMESTIC WATER

HEATER ROUTE TO NEAREST FLOOR DRAIN

PRESSURE GAUGE

THERMOMETER

STEAM SUPPLY

LPS OR MPS

H E

A T

E R

A B

O V

E

2"

M

IN

6"

000 1' 2' 4'

SCALE:

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

BLDG. 1

BLDG. 7

BLDG. 50

NEW

ADDITION

KEY PLAN

CBRE Heery International, Inc.

125 South Dubuque Street, Suite 500, Iowa City, IA 52240-4003

319.354.4700 AE PROJECT NO. : 14980

CONSTRUCTION DOCUMENTS

- 100% CD ISSUE

FULLY SPRINKLERED

EXPAND SPECIALTY CARE

ADDITION

VA# 636-803

BLDG 50

10/05/2018

IOWA CITY, IA

1/2" = 1'-0"

PROJECT NO.: HII-1810200

Dwg. of 118

C

H

II

P

R J \P

-H

II

-1

-V A

-S p e c C lin ic

-P h a s e

P e te r.

M c d e rm o tt c b re

.c o m

.r v t

/4 /2

:2

:1

P

M

50-P03

PLUMBING PLANS LOWER LEVEL

DH HRO 65

PLUMBING UNDERGROUND KEYPLAN

1/2" = 1'-0"1

PLUMBING UNDERGROUND ENLARGE PLAN

PLUMBING LOWER LEVEL KEYPLAN

3/8" = 1'-0"2

PLUMBING ABOVE FLOOR ENLARGE PLAN - LOWER LEVEL

NOT TO SCALE

A

CONNECTIONS TO DOMESTIC WATER HEATER [VA# 223500-01]

Revisions: Date:

"WAS OMITTED FROM THE ORIGINAL SET OF DRAWINGS BY MISTAKE"

Sheets
50-P01 - PLUMBING LEGENDS, NOTES, SYMBOLS AND ABBREVIATIONS
50-P02 - PLUMBING DETAILS AND SCHEDULES
50-P03 - PLUMBING PLANS LOWER LEVEL
50-P04 - PLUMBING SANITARY PLAN LEVEL 1
50-P05 - PLUMBING DOMESTIC WATER PLAN LEVEL 1
50-P06 - PLUMBING SANITARY PLAN LEVEL 2
50-P07 - PLUMBING DOMESTIC WATER PLAN LEVEL 2
50-P08 - PLUMBING PLAN LEVEL 3 ROOF
50-P09 - PLUMBING SANITARY SEWER RISER DIAGRAM
50-P10 - PLUMBING SANITARY SEWER RISER DIAGRAM FUTURE LEVEL 3
50-P11 - PLUMBING DOMESTIC WATER RISER DIAGRAM
50-P12 - PLUMBING DOMESTIC WATER RISER DIAGRAM LEVELS 1 AND 2
50-P13 - DOMESTIC WATER LEGIONELLA PREVENTION DIAGRAMS

File details come from the government source that posted it.