CAD drawings NAVAHCS.pdf

PDF 2 MB Posted

Attached to
6640--VA Prescott Chemistry/Immunochemistry CPT IDIQ Federal contract opportunity
Solicitation number
36C26223R0180
Issued by
Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 22

About this file

This document contains CAD drawings for the NAVAHCS Clinical Laboratory and Pharmacy Building. The drawings provide detailed floor plans, elevations, and equipment layouts for the upper level laboratory and pharmacy areas of the facility. Key details include the locations of laboratory and pharmacy equipment, furniture, and accessories, as well as dimensions, room names, and references to related specification sheets. The drawings are part of a solicitation (Solicitation Number: 36C26223R0180) for a Department of Veterans Affairs IDIQ contract to provide chemistry and immunochemistry services at the Prescott, Arizona VA Medical Center.

View the file

Other files for this federal contract opportunity

Other files attached to 6640--VA Prescott Chemistry/Immunochemistry CPT IDIQ, newest first.
File Type Posted
CHEM-IA-A1C_One_Day_Workload-070124.xlsx XLSX spreadsheet
Vendor Questions - RFP 36C26223R0180.xlsx XLSX spreadsheet
Amendment 36C26223R0180 0003.docx DOCX document
36C26223R0180 0003_1.docx DOCX document
Attachment D - VA Handbook 6500.6 PRE - 0002.pdf PDF
Attachment C - BAA PRE - 0002.doc DOC document
Attachment B ChemistryImmunoassay SOW PRE - 0002.docx DOCX document
Attachment A ChemistryImmunoassay Schedule PRE - 0002.xlsx XLSX spreadsheet
ChemIA Tradeoffs RFP 36C26223R0180 PRE - 0002.docx DOCX document
Amendment 36C26223R0180 0002.docx DOCX document
36C26223R0180 0002_1.docx DOCX document
36C26223R0180 Vendor Responses for VA Prescott.pdf PDF
36C26223R0180 0001_1.docx DOCX document
36C26223R0180.docx DOCX document
Attachment C - BAA PRE.doc DOC document
Attachment B ChemistryImmunoassay SOW PRE.docx DOCX document
Attachment D - VA Handbook 6500.6 PRE.pdf PDF
Attachment A ChemistryImmunoassay Schedule PRE.xlsx XLSX spreadsheet
ChemIA Tradeoffs RFP 36C26223R0180 PRE.docx DOCX document
Show all 19

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

DN

UP

DN

D E F G H

0.5

G.3E.3

AS511

B

/A AS116

/A AS115

/3

URINALYSIS-N ISLAND

AS402

/1

MICRO-N

AS402

/2

MICRO-S ISLAND

AS402

/1

URINALYSIS-S ISLAND

AS403

/2

HEMO-N ISLAND

AS403

/3

HEMO-S ISLAND

AS403

/4

CHEMISTRY-N ISLAND

AS403

A S

B L

O O

D B

A N

K /R

E F

R

IG

E R

A T

IO

N

F

R E

E Z

E R

A S

S P

E C

IM

E

N D

R O

P O

F F

P

R O

C E

S S

IN

G

A S

/6

CHEMISTRY-S

AS403

A S

/1 AS404

/2 AS404

/5 AS403

A S

0.1

AS521

A

5A

115B

9A

A

A

S -2

G

G

A A

B

B

H H

H

H

H

A

F2

F2

F

F

F2

B

A

A

A

B

F

F2

E2 F2

F

A

A A

D B

F

F1

B

E

F1

A

B

B1

B1

UPPER LEVELAREA C

REFER TO

UPPER LEVELAREA B

REFER TO

AS710

8'

A

J

J

A

B

12' - 2" 3' - 0" 13' - 2"

11' - 6" 2' - 9" 8' - 0" 1' - 0" 4' - 5" 9' - 0" 2' - 8" 5' - 4" 5' - 1"

6'

" 3

8"

2'

7' - 8"

J

3' - 5" 2' - 3"8' - 0"10' - 5" 10' - 10"

7'

1"

4'

7'

6"

4"

2"

4' - 6"

2' - 0" 3' - 6" 4' - 6"

5' - 9" 2' - 5"

4'

8' - 0"

3' - 7" 1' - 2" 7' - 8"

REFER TO SHEET 164-AS401

FOR LAB EQUIPMENT LAYOUT.

AS416

A

113B

B

B

F

REFER TO SHEET 164-AS401

FOR LAB EQUIPMENT LAYOUT.

2' - 6"

FD

FD

FD

2' - 1" 19' - 2"

3' - 0"

8"

4'

4'

3"

9' - 8" 3' - 0" 9' - 8"

12' - 2" 3' - 0" 13' - 2"

10' - 1" 2' - 1"

7'

3' - 11" 2' - 1"

2"

2' - 1"

10' - 0"

5" 2' - 1"

AS710

AS416

B

LAB

164-115

BLOOD

DRAW

164-111

MEN'S

TOILET

164-139

PHLEBOTOMY

164-109

BLOOD

DRAW

164-114

WOMEN'S

TOILET

164-113

STORAGE

BH & AR

164-117

CORRIDOR

164-119

STAIR

S-2

DELIVERY

STORAGE

164-116

3' - 7"

2' - 0"

AS621

AS621

AS621

AS711

ELEVATOR

AS311

AS621

AS621

L1200

AS531

AS531

AS531

FD

C G

CG

C

GCG

C G

CG

C G

CG

CG

C

GCG

C G

CG

C G

CG

CG

C G

C G

C G

CG CG

C

G CG

C G

CG

CG

CG

C G

C G

C G

CG

29 30

29 29

29 29

30 30

CG

3' - 11" 1' - 11"

2' - 2"

2' - 5"

1' - 8"

7"

2'

F

139B

AS416

AS416 7AS416

AS4166

5"

5'

1"

6'

A102 2

INTERIOR ELEVATION

REFERENCE (MULTIPLE)

PARTITION TYPE IDENTIFICATION

SHEET WHERE DRAWN

ELEVATION NUMBER AND

DIRECTION OF VIEW

KEYED NOTE

Room Name 101 A1

INTERIOR ELEVATION

REFERENCE (SINGLE)

ELEVATION

NUMBER/SHEET

WHERE DRAWN

/9 Ref

999999 / A102

EQUIPMENT/FURNITURE/

ACCESSORY IDENTIFICATION

L80

DOOR IDENTIFICATION

ROOM NAME

ROOM NUMBER

AS101A101

1 DETAIL NUMBER

SHEET NUMBER

DETAIL REFERENCE

SECTION NUMBER

SHEET NUMBER

WALL & BUILDING SECTION

FIRE EXTINGUISHER CABINET

REFER TO DETAIL 7/AS711

NEW DOOR EXISTING DOOR

WINDOW IDENTIFICATION1t

ELECTRICAL PANEL

REFER TO E-SERIES

SHEETS FOR MORE

INFORMATION

ROOF DRAINRD CLEANOUTCO

FLOORDRAINFDCG

CORNER GUARD

NOT INCLUDED IN THIS CONTRACT

TEMPORARY CONSTRUCTION

BARRIER WALL

ARCHITECT + ENGINEERS:CONSULTANTS: Office of Construction and Facilities Management

100% BID DOCUMENT

4/

0/

:0

:3

A

M C

U se rs

\c ro lli n s\ D oc u m e nt s\

3-

IC

D

_c ro lli ns

.r vt

ENLARGED FLOOR PLAN - UPPER LEVEL AREA

A

AS114

13-127

DBMP

CLINICAL LABORATORY AND

PHARMACY BUILDING

07/06/2017

1/4" = 1'-0"AS114

A UPPER LEVEL FLOOR PLAN - AREA A

A ALL DIMENSIONS ARE TO FACE OF FINISHED PARTITIONS AND SHALL BE FIELD VERIFIED

WHERE APPLICABLE BY GENERAL CONTRACTOR PRIOR TO START OF CONSTRUCTION.

B REFER TO SHEET 164-AS501 FOR TYPICAL INTERIOR PARTITION TYPES. REFER TO

SHEETS 164-AS307 AND 164-AS308 FOR EXTERIOR WALL DETAILS.

C REFER TO SHEET 164-G108 FOR TYPICAL TOILET ROOM MOUNTING HEIGHTS.

D REFER TO SHEET 164-G109 FOR TYPICAL MOUNTING HEIGHTS AND CLEARANCES.

E REFER TO SHEET 164-G111 FOR TYPICAL RULES FOOR REFLECTED CEILING PLANS.

F REFER TO SHEET 164-AS601, 160-AS602 AND 160-AS603 FOR DOOR AND INTERIOR

WINDOW SCHEDULE, NOTES AND DETAILS.

G REFER TO SHEET 164-AS303 FOR EXTERIOR WINDOW SCHEDULE.

H REFER TO SHEET 164-AS701 AND 164-AS702 FOR TYPICAL WALL AND FLOOR

PENETRATIONS.

I REFER TO SHEET 164-I601 AND 164-I602 FOR ROOM FINISH SCHEDULE AND FINISHES.

J PAINT FULL HEIGHT EXPOSED DRYWALL SURFACES. REFER TO ROOM FINISH SCHEDULE.

K REFER TO ELECTRICAL SHEETS (E-SERIES) FOR ELECTICAL PLANS, FIXTURE AND

EQUIPMENT SCHEDULES.

L REFER TO PLUMBING SHEETS (P-SERIES) SHEETS FOR PLUMBING PLANS, FIXTURE AND

EQUIPMENT SCHEDULES AND RISER DIAGRAMS.

M REFER TO PLUMBING SHEETS (P-SERIES) FOR FLOOR DRAIN AND CLEANOUT LOCATIONS

AND INFORMATION.

N PROVIDE 8" HIGH X 16 GAUGE X 48" CONTINUOUS BACK-UP BLOCKING PLATES SECURELY

ANCHORED WITH FLAT HEAD SCREWS OVER METAL STUDS BEHIND ALL TOILET

ACCESSORIES, BASE CABINETS, WALL CABINETS, MILLWORK, SHELVING, VISUAL DISPLAY

BOARDS, WALL/HANDRAIL (NEW WALLS) AND ALL OTHER SURFACE MOUNTED ITEMS.

REFER TO 2/AS501.

FLOORPLANKEYNOTES GENERAL NOTES

1 EXISTING ELECTRICAL. REFER TO ELECTRICAL SHEETS FOR MORE INFORMATION.

2 EXISTING HM DOOR TO REMAIN. FILL WITH CONCRETE TO ACHIEVE 90 MIN. FIRE

RATING. SAND SMOOTH AND PAINT. WIDTH=4-0", HEIGHT=7'-0", THICKNESS=1 3/4".

3 EXISTING DOOR TO REMAIN. PAINT.

4 REFER TO STRUCTURAL SHEETS (S-SERIES) FOR FOUNDATION WALL PENETRATIONS.

5 PROVIDE STEEL TUBE POSTS ANCHORED TO FLOOR AT 4'-0" O.C. FOR LOW HEIGHT,

UNBRACED WALLS.

6 CASEWORK VENDOR TO PROVIDE SHOP DRAWINGS FOR REVIEW BY OWNER AND

ARCHITECT.

7 LOCATION OF FUTURE PNUEMATIC TUBE SYSTEM UNIT BY SWISSLOG OR APPROVED

EQUAL. CONTRACTOR TO INSTALL TUBES ONLY AND STUB ABOVE CEILING. REFER

TO MECHANICAL SHEETS.

8 ENCLOSURE FOR ELECTRICAL WIRING AND PLUMBING PIPING FROM FLOOR BELOW.

REFER TO PLUMBING & ELECTRICAL SHEETS FOR LOCATIONS.

9 NOT USED.

10 NOT USED.

11 NOT USED.

12 NOT USED.

13 PARAPET WALL.

14 SAFETY STATION BY GUARDIAN MODEL NO. GBF2150 OR APPROVED EQUAL. SAFETY

STATION LOCATIONS SHALL BE IDENTIFIED W/ 3'-0" X 3'-0" SQUARE SYMBOL PAINTED

ON FLOOR. NOT IN CONTRACT.

15 LOCATION FOR MOBILE CART SUPPLIED BY OWNER.

16 NOT USED.

17 EXISTING AUTOMATIC SLIDING DOOR.

18 CUBICLE CURTAIN FURNISHED AND INSTALLED BY OWNER.

19 NOT USED.

20 NOT USED.

21 BICYCLE RACK BY UPBEAT OR APPROVED EQUAL. MODEL:3-LOOP, FINISH POWDER

COATED SURFACE MOUNT TO CONCRETE.

22 CONCRETE PAVED AREA. SHADING INDICATES CONCRETE COLOR AND SEALER.

CONCRETE COLOR AND SEALER BY DAVIDS COLORS OR APPROVED EQUAL. PROVIDE

CONTROL JOINTS AS INDICATED.

23 NEW WALL FILL-IN BY OTHERS.

24 EXISTING PIPING. REFER TO MECHANICAL OR PLUMBING SHEETS FOR MORE

INFORMATION.

25 NOT USED.

26 NOT USED.

27 2" EXPANSION JOINT. REFER TO EXPANSION JOINT DETAILS ON SHEET AS531.

28 LOCATE DEDICATION PLAQUE AT BASE OF COLUMN. REFER TO CONTRACTING

OFFICER'S REPRESENTATIVE (COR) FOR DETAILS.

29 DRAIN HUB AT COUNTERTOP. REFER TO DETAIL 7/AS701.

30 2" DIAMETER GROMMET W/ PLASTIC CAP. PROVIDE AT ALL KNEEWELLS. CASEWORK

VENDOR TO COORDINATE.

31 CONCRETE STOOP NOT INCLUDED IN CONTRACT.

32 12" WIDE X 48" LONG PLANK FIN BY 3FORM OR APPROVED EQUAL.

33 CANOPY ABOVE.

34 METAL LADDER.

35 CONCRETE STOOP.

36 GRAVEL FILL. MULTI-ROSE COLOR MIXED WITH COARSE 3/4" NOMINAL SIZE ASTM C

1549.

44 ADDITIONAL COMPACTED FILL IN THIS AREA AS REQUIRED. REFER TO CIVIL AND

STRUCTURAL SHEETS FOR MORE INFORMATION.

45 42" HIGH METAL GUARDRAIL WITH GATE.

46 UNDERGROUND TRENCH DRAIN. REFER TO DETAIL 5/AS315. [DEDUCT ALTERNATE.

REFER TO DEDUCT ALTERNATES LIST ON SHEET G103].

47 GUTTER DOWNSPOUT. TYPICAL AT EACH COLUMN. REFER TO DETAIL 7/AS315.

48 COLUMN WRAP. REFER TO DETAIL 6/AS315 AND 7/AS315.

FLOOR PLAN LEGEND

FIXTURESANDACCESSORIES

F0230 CHAIR, ROTARY, LABORATORY

F0275A CHAIR, SWIVEL, MEDIUM BACK

F0280 CHAIR, SWIVEL, LOW BACK

F2010 BASKET, WASTEPAPER, STEP-ON

L1200 CABINET, SPECIMEN, PASS THRU, CRS

U0114 WIRE SHELVING, 12X36X72

U0115 WIRE SHELVING, 12X48X72

REFER TO SEPS-FURNITURE AND ACCESSORIES SCHEDULE FOR MORE INFORMATION.

VHALONHanS2 Rectangle "Pony-wall" has been eliminated and is now an open space.

VHALONHanS2 Rectangle "Pony-wall" has been eliminated and is now an open space.

VHALONHanS2 Rectangle Countertop space available for tertiary analyzers (if needed).

VHALONHanS2 Rectangle Countertop space available for tertiary analyzers (if needed).

VHALONHanS2 Rectangle Open space available for floor-model tertiary analyzers (if needed).

D E F G H H.3

G.3

AS621

E.3

AS621

/3

URINALYSIS-N ISLAND

AS402

/1

MICRO-N

AS402

/2

MICRO-S ISLAND

AS402

/1

URINALYSIS-S ISLAND

AS403

/2

HEMO-N ISLAND

AS403

/3

HEMO-S ISLAND

AS403

A S

/4

CHEMISTRY-N ISLAND

AS403

A S

B

LO

O D

B A

N K

/R E

F R

IG

E

R A

T

IO

N

F R

E E

Z E

R

A S

S P

E C

IM

E

N D

R O

P O

F F

P

R O

C E

S S

IN

G

A S

/6

CHEMISTRY-S

AS403

A S

/1 AS404

/2 AS404

/2 AS401

/5 AS403

A S

L8

L13

L16

L39

L17

L40

L41

L71

L70

L9

L15

L50 L54 L55

L72

L43

L73

L49

L44

L45

L86

L74

L30

L34

L33

L36

L35

L38

L32

L42

L14 L11

L12 L12

L5 L1

L3

L4 L10 L23

L28L25L26

L58 L69 L68

L60

L62L61

L63 L65

L85L19

L67 L57

L22

L29

L46

L47

L48

L53

L59

L66

L

AS311

L24L27

L2

AS621

2' - 1"

2' - 1"

2' - 11" 2' - 0"

2'

3' - 0"

2'

3' - 0"

2'

AS621

AS4015

FURNITURE IS NOT APART OF THIS PACKAGE

FUTURE EXPANSION

1'

6'

DIRTY SINK

D

IR

T Y

S

IN

K

D

IR

T Y

S

IN

K C

L E

A N

S

IN

K

C

LE

A N

S

IN

K

L20

L37

L31

AS416

B

AS416

A

LAB

164-115

PHLEBOTOMY

164-109

BLOOD

DRAW

164-111

MEN'S

TOILET

164-139

BLOOD

DRAW

164-110

BLOOD

DRAW

164-114

WOMEN'S

TOILET

164-113

BLOOD

DRAW

164-112

15 15

15 15

AS311

AS621

AS621

AS621

AS621

12 12

L89 L90

L56 L64

L83/84

L28 AS416

AS416 7AS416

AS4166

G

L75

P-9

VB-1

P-9

OPEN OPEN

P-9 P-9

VB-1 VB-1

SS-5

SS-5

F2010

A5080 A5075 50 50

AS311

OPEN

5' - 1 5/8" 2' - 0" 1"

P-9

VB-1

SS-5

6"

0"

8'

P-9

VB-1

SS-5

U2012

A5107A5108

AS621

AS621

AS621

M1410

OPEN

P-9

VB-1

U1002

P-9

VB-1

F3200

P-13

VB-1

LIGHT SWITCH

LIGHT DIMMER

DATA & PHONE

CARD READER

ELECTRICAL OUTLETS WIRE MOLD

PT

L80

FINISH TAG

REFER TO ROOM FINISH SCHEDULE AND LEGEND ON SHEET 164-I601

EQUIPMENT/FURNITURE/ACCESSORIES TAG

REFER TO:

LAB EQUIPMENT SCHEDULE: SHEETS 164-

AS401 (QUICK REFERENCE) & 164-Q601

PHARMACY EQUIPMENT SHEDULE: SHEETS

164-AS408 (QUICK REFERENCE) & 164-Q602

SEPS FIXTURES AND ACCESSORIES

SCHEDULE: SHEETS 164-Q603 & Q604

FIRE ALARM

HORN STROBE

FIRE ALARM

STROBE ONLY

AV V

ITEMS INDICATED WITH DASH DOT LINE

TYPE NOT INCLUDED IN THIS CONTRACT

M A

X

C E

N T

E R

L

IN

E O

F O

P E

N

IN

G

8"

PAPER TOWEL

DISPENSER

SOAP

DISPENSER

GLOVE

DISPENSER

SHARPS

DISPOSAL

SANITIZER

DISPENSER

LOTION

DISPENSER

ARCHITECT + ENGINEERS:CONSULTANTS: Office of Construction and Facilities Management

100% BID DOCUMENT

4/

0/

:0

:4

A

M C

U se rs

\c ro lli n s\ D oc u m e nt s\

3-

IC

D

_c ro lli ns

.r vt

ENLARGED PLAN & INTERIOR ELEVATIONS - LAB

AS401

13-127

DBMP

CLINICAL LABORATORY AND

PHARMACY BUILDING

07/06/2017

1/4" = 1'-0"AS401

A ENLARGEDFLOORPLAN - LAB

GENERAL NOTES

A ALL DIMENSIONS ARE TO FACE OF FINISHED PARTITIONS AND SHALL BE FIELD VERIFIED

WHERE APPLICABLE BY GENERAL CONTRACTOR PRIOR TO START OF CONSTRUCTION.

B REFER TO SHEET 164-AS501 FOR TYPICAL INTERIOR PARTITION TYPES. REFER TO

SHEETS 164-AS307 AND 164-AS308 FOR EXTERIOR WALL DETAILS.

C REFER TO SHEET 164-G108 FOR TYPICAL TOILET ROOM MOUNTING HEIGHTS.

D REFER TO SHEET 164-G109 FOR TYPICAL MOUNTING HEIGHTS AND CLEARANCES.

E REFER TO SHEET 164-G111 FOR TYPICAL RULES FOOR REFLECTED CEILING PLANS.

F REFER TO SHEET 164-AS601, 160-AS602 AND 160-AS603 FOR DOOR AND INTERIOR

WINDOW SCHEDULE, NOTES AND DETAILS.

G REFER TO SHEET 164-AS303 FOR EXTERIOR WINDOW SCHEDULE.

H REFER TO SHEET 164-AS701 AND 164-AS702 FOR TYPICAL WALL AND FLOOR

PENETRATIONS.

I REFER TO SHEET 164-I601 AND 164-I602 FOR ROOM FINISH SCHEDULE AND FINISHES.

J PAINT FULL HEIGHT EXPOSED DRYWALL SURFACES. REFER TO ROOM FINISH SCHEDULE.

K REFER TO ELECTRICAL SHEETS (E-SERIES) FOR ELECTICAL PLANS, FIXTURE AND

EQUIPMENT SCHEDULES.

L REFER TO PLUMBING SHEETS (P-SERIES) SHEETS FOR PLUMBING PLANS, FIXTURE AND

EQUIPMENT SCHEDULES AND RISER DIAGRAMS.

M REFER TO PLUMBING SHEETS (P-SERIES) FOR FLOOR DRAIN AND CLEANOUT LOCATIONS

AND INFORMATION.

N PROVIDE 8" HIGH X 16 GAUGE X 48" CONTINUOUS BACK-UP BLOCKING PLATES SECURELY

ANCHORED WITH FLAT HEAD SCREWS OVER METAL STUDS BEHIND ALL TOILET

ACCESSORIES, BASE CABINETS, WALL CABINETS, MILLWORK, SHELVING, VISUAL DISPLAY

BOARDS, WALL/HANDRAIL (NEW WALLS) AND ALL OTHER SURFACE MOUNTED ITEMS.

REFER TO 2/AS501.

1/2" = 1'-0"AS401

2 PHLEBOTOMY 109NORTHELEVATION

1/2" = 1'-0"AS401

3 PHLEBOTOMY 109 EAST ELEVATION

INTERIOR ELEVATION LEGEND

INTERIORELEVATION KEY NOTES

1 ADJUSTABLE SHELVING WITH SUPPORT STRUCTURE, HORIZONTAL PIPE CHASE (3”D X

5”H) SUPPLIED BY CASEWORK CONTRACTOR.

2 VERTICAL PIPE CHASE ( 2’W X6”D X 84”H) SUPPLIED BY CASEWORK CONTRACTOR.

3 CO2 TANKS. PROVIDED AND INSTALLED BY PRESCOTT VA.

4 NOT USED.

5 EXISTING CPU RELOCATED. COORDINATE WITH PRESCOTT VA.

6 NOT USED.

7 LOCATION OF FUTURE PNUEMATIC TUBE SYSTEM UNIT BY SWISSLOG OR APPROVED

EQUAL. CONTRACTOR TO INSTALL TUBES ONLY AND STUB ABOVE CEILING. REFER

TO MECHANICAL SHEETS.

8 DOOR BELL CHIME FOR DOUBLE DELIVERY DOORS AT LOWER LEVEL, ENTRANCE TO

BLOOD DRAW AND PHARMACY NIGHT PICK UP WINDOW. REFER TO ELECTRICAL

SHEETS.

9 NOT USED.

10 FIRE EXTINGUISHER CABINET. REFER TO ARCHITECTURAL SHEETS FOR LOCATIONS.

11 1-HOUR FIRE SHUTTER. REFER TO DOOR SCHEDULE ON SHEET 164-AS601. REFER

TO ROOM FINISH LEGEND.

12 BASE BID: PLASTIC LAMINATE UPPER AND/OR BASE CABINETS THAT REQUIRE A SINK

TO BE INSTALLED. REMAINING UPPER AND/OR BASE CABINETS NOT INCLUDED IN

THIS CONTRACT (INDICATED BY DASH DOT LINE TYPE).

13 BASE BID: METAL UPPER AND/OR BASE CABINETS FOR LABORATORY 164-115 ISLANDS

AND UPPER AND/OR BASE CABINETS THAT REQUIRE A SINK TO BE INSTALLED.

REMAINING UPPER AND/OR BASE CABINETS NOT INCLUDED IN THIS CONTRACT

(INDICATED BY DASH DOT LINE TYPE).

14 SAFETY STATION WITH SHOWER EYE WASH BY GUARDIAN MODEL#GBF2150 OR

APPROVED EQUAL. WALL FINISH TO BE MARLITE FRP WATER RESISTANT PANEL OR

APPROVED EQUAL. REFER TO ROOM FINISH LEGEND.

15 CUBICAL CURTAIN TRACK. REFER TO DETAIL 7/164-AS531 & ROOM FINISH LEGEND.

16 SPECIMAN PASS-THROUGH BY AMERICAN SPECIALITIES, INC. MODEL #0515 OR

APPROVED EQUAL.

17 DECK MOUNTED EYEWASH BY BRADLEY S19-270E OR APPROVED EQUAL. REFER TO

PLUMBING DRAWINGS..

18 EXISTING - TEM TRACK 2’-6” X 2’-0” COUNTERTOP MODEL, PLACEMENT. SUPPLIED BY

PRESCOT VA.

19 HANDRAIL BY INPRO INC. #900M OR APPROVED EQUAL. REFER TO ROOM FINISH

LEGEND.

20 FASTCAP – SPEEDBRACE BRACKET 21” X 24” #SB-21X24WH. PROVIDE STAINLESS

STEEL TYPE IN HISTOLOGY 164-016, CYTOLOGY 164-015, CHEMO 164-125 AND STERILE

PREP 164-126. REFER TO ROOM FINISH LEGEND.

21 EXISTING CASEWORK WALL AND BASE CABINETS TO BE RELOCATED FROM EXISTING

PHARMACY LOCATION (INDICATED BY DASHED LINE TYPE).

22 CPU SHELF BY CASEWORK SUBCONTRACTOR.

23 EXISTING BASE CABINETS RELOCATED WITH NEW PLASTIC LAMINATE COUNTER TOP

FOR COMPOUNDING AREA IN PHARMACY. SWITCH EXISTING SINK CABINET WITH

EXISTING OPEN SHELVES. REUSE EXISTING UPPER SHELVES.

24 NOT USED.

25 NOT USED.

26 NOT USED.

27 NOT USED.

28 EXISTING FILE STORAGE INSTALLED BY PRESCOTT VA FOR OFFICE 640-120.

29 LABORATORY REQUESTED A DESIGNATED LOCATION, 2’-6” X 2’-6,” TO STORE A

BACK-UP EQUIPMENT ITEM.

30 10” D PLASTIC LAMINATE SHELF SUPPORTED BY FASTCAP-SPEEDBRACE

BRACKET#SB-8X12WH SIZE 8” X 12”.

31 UNDERCOUNTER REFRIGERATOR (PHARMACY) SUPPLIED AND INSTALLED BY

PRESCOTT VA.

32 AIR DUCT. REFER TO MECHANICAL SHEETS FOR SPECIFICATIONS.

33 NOT USED.

34 ELECTRIC WATER FOUNTAIN. REFER TO PLUMBING DRAWINGS FOR MODEL AND

INSTALLATION.

35 LIGHT FIXTURE. REFER TO ELECTRICAL SHEETS FOR SPECIFICATIONS.

36 PLASTIC LAMINATE CABINET WITH ADJUSTABLE SHELVES, 2’D X 4’W X 7’-0”H. NOT

INCLUDED IN THIS CONTRACT.

37 STAINLESS STEEL UPPER AND BASE CABINETS AND SOLID SURFACE COUNTERTOPS

IN LABORATORY ROOMS; CHEMO 164-125 AND STERILE PREP 164-126 NOT INCLUDED

IN THIS CONTRACT (INDICATED BY DASH DOT LINE TYPE).

38 NOT USED.

39 24" WIDE X 30" HIGH X 3/4" DEEP PEG BOARD WITH 32-6" LONG 1/2" DIAMETER WHITE

POLYPROPYLENE PEGS PROVIDED BY LAB FURNITURE MANUFACTURER.

40 EXHAUST FOR BIOSAFETY CABINET. REFER TO MECHANICAL SHEETS.

41 CONTINUOUS 8" HIGH 16 GA. SHEET METAL BACKING PLATE BEHIND LOCATIONS OF

WALL MOUNTED EQUIPMENT. REFER TO DETAIL 2/AS501.

42 LOUVER CURTAIN WALL PANEL.

43 CONTINUOUS GRID DIFFUSER. REFER TO MECHANICAL SHEETS.

44 EXISTING PASS-THRU CABINET, RELOCATED FROM EXISTING PHARMACY.

45 REMOVABLE METAL PANEL SUPPLIED BY CASEWORK CONTRACTOR AT KNEE SPACE.

46 PLANK FIN BY 3FORM (300.36) OR APPROVED EQUAL, WIDTH: 1'-0" X LENGTH: 4'-0".

REFER TO ROOM FINISH LEGEND FOR MORE INFORMATION. PROVIDE STEEL BACKING

PLATE. REFER TO DETAIL 2/AS501.

47 NOT USED.

48 2" EXPANSION JOINT. REFER TO DETAIL 13/AS531.

49 NOT USED.

50 WAYFINDING SIGNAGE. NOT INCLUDED IN THIS CONTRACT.

51 PUSH BUTTON DOOR BELL. REFER TO ELECTRICAL SHEETS.

1/2" = 1'-0"AS401

1 TYPICAL BLOOD DRAW

1/2" = 1'-0"AS401

4 TYPICAL BLOOD DRAW

1/2" = 1'-0"AS401

5 TYPICAL BLOOD DRAW

1/2" = 1'-0"AS401

6 TYPICAL BLOOD DRAW

LAB EQUIPMENT

L60 URINE ANALYZER

L61 URINE ANALYZER

L62 COMPUTER

L63 COMPUTER + 2 PRINTERS

L64 BLOOD CULTURING SYSTEM

L65 COMPUTER

L66 FUME HOOD

L67 COMPUTER

L68 PRINTER

L69 MOLECULAR DIAGNOSTIC SYSTEM

L70 REFRIGERATOR

L71 REFRIGERATOR

L72 MICROSCOPE

L73 COMPUTER

L74 LABEL PRINTER

L75 BAR CODE PRINTER

L83/84 CELL ANALYZER

L85 CELL IMAGE ANALYSIS SYSTEM

L86 CENTRIFUGE

L87 REFRIGERATOR

L88 FREEZER

L89 COMPUTER

L90 COMPUTER

L91 AIR COMPRESSOR

LAB EQUIPMENT

L30 LABEL PRINTER

L31 CPU (CENTRAL PROCESSING UNIT)

L32 CPU

L33 MTS CENTRIFUGE

L34 AGGLUTINATION VIEWER

L35 CENTRIFUGE

L36 PLATELET AGITATOR

L37 BLOOD THAWER

L38 COMPUTER

L39 REFRIGERATOR

L40 REFRIGERATOR

L41 FREEZER

L42 PRINTER

L43 MONOCHROME PRINTER

L44 CENTRIFUGE

L45 CENTRIFUGE

L46 TIME AND DATE STAMP

L47 SCALE

L48 COMPUTER

L49 PRINTER

L50 REFRIGERATOR

L52 BIOSAFETY CABINET

L53 DELUXE MIXER

L54 INCUBATOR

L55 INCUBATOR

L56 BACTERIAL ID SYSTEM

L57 COMPUTER

L58 PRINTER + CPU

L59 PROCESSOR

LAB EQUIPMENT

L1 AIR-DRIVEN ULTRACENTRIFUGE

L2 STAINLESS STEEL CART

L3 PRIMARY TUBE CENTRIFUGE

L4 CENTRIFUGE

L5 COMPUTER

L8 REFRIGERATOR

L9 CLINICAL CHEMISTRY &

IMMUNOASSAY ANALYZER

L10 COMPUTER

L11 UPS (UNITERRUPTIBLE POWER

SUPPLY)

L12 PRINTER

L13 CLINICAL CHEMISTRY &

IMMUNOASSAY ANALYZER

L14 UPS (UNITERRUPTIBLE POWER

SUPPLY)

L15 REFRIGERATOR

L16 FREEZER

L17 FREEZER

L19 UPS+PRINTER+CPU

L20 CPU + UPS

L22 HEMOGLOBIN ANALYZER + RACK

LOADER

L23 COMPUTER

L24 CYTOPRO CYTOCENTRIFUGE

L25 SLIDE STAINER CYTOCENTRIFUGE

L26 COMPUTER

L27 MICROSCOPE

L28 COAGULATION ANALYZER

L29 LABEL PRINTER

NOTE:

FOR ADDITIONAL INFORMATION ON LAB EQUIPMENT, REFER

TO THE LAB EQUIPMENT SCHEDULE ON SHEET 164-Q601.

LAB EQUIPMENT NOT INCLUDED IN CONTRACT UNLESS

NOTED OTHERWISE.

1/2" = 1'-0"

LAB + PHARMACY TYPICAL MOUNTING HEIGHTS

VHALONHanS2 Rectangle Countertop space available for tertiary analyzers.

VHALONHanS2 Rectangle Countertop space available for tertiary analyzers.

VHALONHanS2 Rectangle "Pony-wall" has been eliminated and is now an open space.

VHALONHanS2 Rectangle "Pony-wall" has been eliminated and is now an open space.

VHALONHanS2 Rectangle Open space available for floor-model tertiary analyzers (if needed).

ARCHITECT + ENGINEERS:CONSULTANTS: Office of Construction and Facilities Management

100% BID DOCUMENT

2/

/2

1:

:1

A

M C

U se rs

\d b ib b s\ D o cu m e nt s\

-1

I C

D db ib b s.

rv t

3D VIEWS 13-127

DBMP

CLINICAL LABORATORY AND

PHARMACY BUILDING

12/03/2015

AS900

AS900

VHALONHanS2 Polygonal Line "Pony-wall" has been eliminated and is now an open space.

VHALONHanS2 Polygonal Line Countertop space available for tertiary analyzers.

VHALONHanS2 Polygonal Line "Pony-wall" has been eliminated and is now an open space.

VHALONHanS2 Polygonal Line Countertop space available for tertiary analyzers.

File details come from the government source that posted it. Updated .