ATTACHMENT B - Cyber Power Envirosensor Specifications Sheet.pdf
PDF 429 KB Posted
- Attached to
- Z1DA--ERHM Infrastructure Upgrades, LAACC
- Solicitation number
- 36C26221B0006_1
About this file
This document contains a specifications sheet for an environmental sensor and information on a related federal contract opportunity. The specifications sheet provides details on a CyberPower environmental sensor that monitors temperature and humidity for server rooms and datacenters. It connects to SNMP cards and UPS systems to provide real-time readings, has a range of 32-158°F and 0-90% RH with certain accuracy levels, and includes four input contact closures.
The federal contract opportunity is being issued by the VA Greater Los Angeles Healthcare System to improve infrastructure supporting their new EHRM system. The solicitation number provided is for infrastructure upgrades at their LAACC location, with work including general construction, alterations, mechanical and electrical work. The project size is between $2-5 million and will be set aside 100% for verified SDVOSBs. The solicitation is expected to be released on May 21, 2021 via SAM.gov, with a site visit scheduled after. The point of contact is listed for any questions.
View the file
Other files
Show all 12
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Environmental Sensor Datacenter/Server Room Temperature and Humidity Monitoring
The CyberPower Environmental Sensor (ENVIROSENSOR) provides complete UPS monitoring and management with real-time temperature and humidity readings when connected to the
RMCARD203, RMCARD205, RMCARD303,
and most Switched and Monitored PDUs.
Event notifications notify administrators remotely whenever a defined event happens.
Additionally, the Environmental Sensor provides four input contact closures, allowing users to monitor the status of connected devices, such as a door switch sensor.
A Three-Year Warranty ensures the ENVIROSENSOR has passed our highest quality standards in design, assembly, material and workmanship.
Typical Applications
• Servers
• IT Closets
• Network Devices
• Datacenters
Features
• Real-time monitoring via connection to SNMP Cards
• Temperature and humidity monitoring
• Fahrenheit and Celsius readings
• 32°F – 158°F w/ accuracy of 1.8°F
• 0-90 RH w/ accuracy of ± 2%
• (4) Input Contact Closures
©2015 CyberPower Systems (USA), Inc. All rights reserved.
CyberPower reserves the right to change, without prior notice, product offerings or specifications. *Visit CPSww.com for UPS model compatibility list.
Environmental Sensor Datacenter/Server Room Temperature and Humidity Monitoring
GENERAL
Type Environmental Sensor
INPUT
Voltage 12V – supplied via SNMP Connection
PHYSICAL SIZE
Dimensions (LxWxH) 2.24 x 1.46 x 1.15 in. / 57 x 37 x 29.2 mm
Weight 1.16 oz / 33 g
MEASUREMENT RANGE & ACCURACY
Temperature 32°F to 158°F with accuracy of ± 1.8°F 0°C to 70°C with accuracy of ± 1°c
Humidity 0-90 RH with accuracy ± 2%
COMMUNICATION
Connection Port RJ45 Ethernet Port (10 ft. Ethernet Cable Included)
Input Contact Closure 4
CERTIFICATIONS
Environmental RoHS Compliant
WARRANTY
Product Warranty 3 Year
File details come from the government source that posted it. Updated .