36C26125R0043.docx
DOCX document 20 KB Posted
- Solicitation number
- 36C26125R0043
About this file
This is a Sources Sought Notice from the Department of Veterans Affairs (VA) Network Contracting Office 21 (NCO 21) seeking market research for high-voltage electrical work to repair three leaky transformers at the Palo Alto VA Health Care System in California. The project is estimated to be less than $25,000, with a targeted Request for Proposal (RFP) release in May 2025 and a response deadline of May 6, 2025, at 3:00 PM Pacific Time. The procurement is set aside for Service-Disabled Veteran-Owned Small Businesses (SDVOSB) under NAICS code 236220 (Commercial and Institutional Building Construction) and Product Service Code 5975 (Electrical Hardware and Supplies).
The VA is requesting interested contractors to submit detailed capability information, including business size, socio-economic status, SAM registration, bonding capacity, teaming arrangements, and experience with similar public works projects. Respondents must provide a comprehensive 10-page submission demonstrating their qualifications, past performance on repair/remodel projects, and ability to manage electrical transformer repairs in medical facilities. The sources sought notice emphasizes that this is a market research effort and does not constitute a formal solicitation, with the primary goal of assessing industry capabilities and supporting acquisition planning for the transformer repair project.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| FINAL 01 35 26 Safety Requirements.pdf | ||
| FINAL SECTION 26 05 11.pdf | ||
| Service Contract Wage Determinations.pdf | ||
| REQUEST FOR INFORMATION FORM.docx | DOCX document | |
| 36C26125R0043_2.docx | DOCX document | |
| Transformer SOW.docx | DOCX document | |
| 01 35 26 Safety Requirements.pdf | ||
| SECTION 26 05 11.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Sources Sought Notice
| SUBJECT* |
| NEW - High-Volt Electrical Work to Repair 3 Leaky Transformers PAD |
GENERAL INFORMATION
| CONTRACTING OFFICE’S ZIP CODE* |
| 96813 |
| SOLICITATION NUMBER* |
| 36C26125R0043 |
| RESPONSE DATE/TIME/ZONE |
| 05-06-2025 3:00 PM PACIFIC TIME, LOS ANGELES, USA |
| ARCHIVE |
| 60 DAYS AFTER THE RESPONSE DATE |
| RECOVERY ACT FUNDS |
| N |
| SET-ASIDE |
| SDVOSBC |
| PRODUCT SERVICE CODE* |
| 5975 |
| NAICS CODE* |
| 236220 |
| CONTRACTING OFFICE ADDRESS |
| Department of Veterans Affairs |
Network Contracting Office 21 (NCO 21) VA Pacific Islands Health Care System 711 Kapiolani Blvd Suite 200 Honolulu HI 96813
POINT OF CONTACT*
Christopher Aguon christopher.aguon@va.gov Contract Specialist
PLACE OF PERFORMANCE
| ADDRESS |
| Department of Veteran Affairs |
Palo Alto Health Care System
Palo Alto
California
| POSTAL CODE |
| 94304 |
COUNTRY
ADDITIONAL INFORMATION
| AGENCY’S URL |
| https://sam.gov |
| URL DESCRIPTION |
| Repair Transformer |
| AGENCY CONTACT’S EMAIL ADDRESS |
| https://sam.gov |
| EMAIL DESCRIPTION |
| christopher.aguon@va.gov |
DESCRIPTION
| *= Required Field |
| Sources Sought Notice |
Sources Sought Notice
Subject: Sources Sought, Repair Leaky Transformer for Department of Veterans Affairs, Veterans Health Administration, Regional Procurement Office West, Network Contracting Office 21 (NCO 21) on behalf of Palo Alto VA Health Care System.
The purpose of this sources sought is to conduct market research to support the procurement of the repairing leaky transformer requirement located at the VA Palo Alto Health Care System, Palo, CA. This notice serves to survey the market to ascertain whether sources can provide the requested services. This notice allows potential contractors to submit a non-binding statement of interest and documentation demonstrating their capability. The sources sought effort is intended to assess industry capabilities and develop/support the intended direction of acquisition planning. NCO 21 is requesting responses from qualified business concerns; the qualifying NAICS code for this effort is 236220 – Commercial and Institutional Building Construction and Product Service Code of 5975 – Electrical Hardware and Supplies.
This sources sought is to gain knowledge of potential qualified sources and their size classifications (Service Disabled/Veteran Owned Small Business (SDVOSB/VOSB), Hub zone, 8(a), small, small disadvantaged, woman owned small business, or large business) relative to NAICS 236220. Responses to this notice, will be used by the Government to make appropriate acquisition decisions. After review of the responses to this notice, a solicitation announcement may be published. Responses to this notice are not considered adequate responses to any corresponding solicitation announcement. All interested offerors will have to respond to the solicitation announcement in addition to responding to this notice. A Request for Proposal (RFP) is anticipated to be released on or before May 2025.
Background: The Department of Veterans Affairs is seeking contractors to perform the required services for the completion of the project identified as repairing leaky transformers per the attached draft statement of work (SOW). Contractors must demonstrate their ability to meet all requirements listed in this notice. See attached draft SOW & Support Documentation for additional information.
The estimated magnitude of this construction project is less than $25,000.00. This information is provided per FAR 36.204.
Potential Offerors must be registered in the System for Award Management (SAM) to be eligible for an award (See https://www.sam.gov/SAM/pages/public/index.jsf ). Potential Offerors must also have a current Online Representations and Certification Application on file with SAM. Service-Disabled Veteran-Owned Small Businesses and Veteran-Owned Small Businesses shall have their ownership and control verified by the Department of Veterans Affairs (VA) and be listed in the Veteran Small Business Certification (VetCert) Veteran Small Business Certification (sba.gov). *In addition to or in place of (VetCert), VA may use the SBA Dynamic Small Business Search (DSBS) as another official source for SDVOSB verifications.
Information Requested: The Government requests that interested parties review the attached SOW & Support Documentation and to provide the following capability information identified below to the Contracting Specialist, Christopher Aguon, at christopher.aguon@va.gov by 15:00 PM PDT on May 6, 2025. Please place “Attention: Repairs for Leaky Transformers at VA Palo Alto HCS” in the subject line of your email.
NOTE: Interested parties are encouraged to provide complete and accurate response to all items, a through m below.
a) Business Size (Large/Small)
b) Business Socio-Economic Status (SDVOSB, WOSB, 8(a), HUBZone, etc.)
c) Identify if you are the Prime contractor or Subcontractor
d) SAM Unique Entity ID (UEI)
e) DUNS number
f) Bonding Capability; per contract and aggregate. Provide amount of aggregate bonding currently available (i.e., amount not committed).
g) Anticipated Teaming Arrangements (if applicable).
h) Is the anticipated period of performance realistic for this project?
i) Experience in managing Construction projects less than $25,000.00. Include general information and technical background describing your firm's experience on contracts requiring similar efforts to meet the program objectives.
j) Experience. Past and present corporate experience on public works (Federal, State, County, or City) major repairs/remodel(s) and/or included major repairs to transformers as appliable with the Draft SOW. Qualifying project[s] must also fall within the same magnitude or greater and be of similar scope and complexity. Similar magnitude is defined as project with award value of less than $25,000.00. Similar scope and complexity are defined as projects that consist of a major repairs/remodel and/or major that demonstrates repairs for leaky transformers in public works building and/or medical facility and involved the supervision of multiple trades.
k) Average price per square foot for each project identified under paragraph (i) above, using the total modified value of the contract.
l) List of Sub-Contractors you intend to use on this project, including but not limited to: Mechanical, Plumbing, Electrical, Controls, and Air-Balance.
m) If applicable, how does your company intend to meet the Limitations on Subcontracting as per 13 CFR 125.6?
n) Are your Sub-Contractors from the local area or will they be coming from out of the area, if so, from where?
The Government requests that interested party submissions in response to this source sought notice be no more than 10 single-sided, type-written pages using Times New Roman 12-point font or larger. Published literature may be any number of pages.
NOTES: Issuance of this notice does not constitute any obligation whatsoever on the part of the Government to procure these services, or to issue a solicitation, nor to notify respondents of the results of this notice. No solicitation documents exist at this time. The Department of Veterans Affairs is neither seeking proposals nor accepting unsolicited proposals, and responses to this notice cannot be accepted as offers. Any information the contractor considers proprietary should be clearly marked as such. The U.S. Government will not pay for any information or administrative costs incurred in response to this sources sought notice.
(End of Document) See attached document: Transformer SOW.
See attached document: SECTION 26 05 11.
See attached document: 01 35 26 Safety Requirements.
Page 1 of
File details come from the government source that posted it. Updated .