36C26124Q1020_6.docx
DOCX document 31 KB Posted
- Solicitation number
- 36C26124Q1020
About this file
This document is an amendment to a previous combined solicitation issued by the Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 21 for Palo Alto fire alarm maintenance and services. The solicitation number is 36C26124Q1020 and it is a total small business set-aside with a NAICS code of 561621. The services required include inspection, testing, and maintenance of fire alarm and sprinkler systems across multiple VA facilities, as well as any necessary repairs. The contract period is for a base year plus 4 option years from 1/1/2025 to 12/31/2029. Quotes are due by 7:00 AM PST on 11/08/2024 and should be submitted to Sable Williams, the contracting officer. The document also includes a Q&A section addressing details about the fire alarm and sprinkler systems, deficiencies, and inspection requirements.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| FA Testing Schedule 2025.pdf | ||
| 36C26124Q1020_7.docx | DOCX document | |
| 36C26124Q1020_5.docx | DOCX document | |
| 36C26124Q1020_4.docx | DOCX document | |
| Attachment 1 - Site Visit Information final.docx | DOCX document | |
| Copy of 2024 FA Device Inventory 10.10.2024 .xlsx | XLSX spreadsheet | |
| 36C26124Q1020_3.docx | DOCX document | |
| S02 - Attach 2 - Past Performance Survey.docx | DOCX document | |
| SAN MATEO COUNTY MENLO PARK WD 2015-5637 27 072224.pdf | ||
| 36C26124Q1020_2.docx | DOCX document | |
| ALAMEDA COUNTY LIVERMORE REV 24 2015-5623 072224.pdf | ||
| PALO ALTO - SANTA CLARA COUNTY WD2015-5641 NO.25 072224.pdf |
Show all 12
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Amendment to a Previous Combined Solicitation
Amendment to a Previous Combined Solicitation
| SUBJECT* |
| Palo Alto Fire Alarm Maintenance Base + 4 Option Years 1/1/25-12/31/29 |
GENERAL INFORMATION
| CONTRACTING OFFICE’S ZIP CODE* |
| 89086 |
| SOLICITATION NUMBER* |
| 36C26124Q1020 |
| RESPONSE DATE/TIME/ZONE |
| 11-08-2024 7:00AM PACIFIC TIME, LOS ANGELES, USA |
| ARCHIVE |
| 30 DAYS AFTER THE RESPONSE DATE |
| RECOVERY ACT FUNDS |
| N |
| SET-ASIDE |
| SDVOSBC |
| PRODUCT SERVICE CODE* |
| H312 |
| NAICS CODE* |
| 561621 |
| CONTRACTING OFFICE ADDRESS |
| Department of Veterans Affairs |
Network Contracting Office 21 VA Southern Nevada Healthcare System 6900 N. Pecos Road, Building 6 North Las Vegas NV 89086
POINT OF CONTACT*
SABLE WILLIAMS
SABLE.WILLIAMS1@VA.GOV
Sable.Williams1@va.gov
PLACE OF PERFORMANCE
ADDRESS
POSTAL CODE
COUNTRY
ADDITIONAL INFORMATION
AGENCY’S URL
URL DESCRIPTION
AGENCY CONTACT’S EMAIL ADDRESS
EMAIL DESCRIPTION
DESCRIPTION
QUESTIONS & ANSWERS FOR 36C26124Q1020 FIRE ALARM SERVICES
Version 1 - 10/18/24
1. The Sam.gov listing and first page of document "36C26124Q1020_3' state that this is a SDVOSB set-aside, however third page states that this is a total small business set-aside. Could you please clarify which set-aside is being used?
Sorry I can not answer questions 1,7,and 8.
2. Will the VA host a formal site visit for all interested offerors?
Yes, supported by the Electronics Shop as scheduled. on Oct 24,25 and 28 2024 @ 9am pst.
3. Can you provide more system information such as model numbers?
With over 60 building we can not provide models for all, however 75% of our building are Notifier, 20% are Simplex and 5% is Edwards.
4. Is this for Fire Alarms only or Fire Alarms and Fire Sprinklers?
Fire Alarm and Sprinklers.
5. Outside of these 5 locations, where are the others located? What are the specific addresses of every building that needs service?
There are only 5 locations.
6. Can you please provide the most recent inspection reports?
Send email request to Anthony.losito@va.gov with specific building report requested.
7. The description on Sam.gov states this is a total small business set aside, but the classification on Sam.gov and the SF 1449 states SDVOSB? Please confirm set aside type Refer to answer of question #1.
8. The NAICS code for this previously was 561621, it is now 922160? 922160 NAICS code appears to be for fire fighting and related services, which is not the scope of work defined in the solicitation. Would the government consider revising the NAICS code back to 561621 to ensure alignment with the scope of work being requested?
Yes naics 561621 will be used instead of 922160
9. How many smoke detectors per building and type
10. How many heat detectors per building and type
11. How many monitor modules per building and type
12. How many relays per building and type
13. How many strobes per building and type
14. How many speaker strobes per building and type Questions 9-14 are on the Excel attachment
15. How many wet sprinkler systems per building Every building has sprinkler protection.
16. How many dry sprinkler systems per building None
17. How many standpipes per building One per building
18. How many deluge systems per building None
19. How many pre-action systems per building None
20. How many chemical systems per building None
21. How many service calls were completed in the last year Approximately 24
22. How many fire alarm repairs were completed in the last year and what repairs were made Approximately 24 with repairs being defective parts, network cards and ground faults.
23. What are the outstanding deficiencies None. All deficiencies from 2024 will be the responsibility of current contractor.
24. How many fire pumps per building, size, and type Only 2 building have pumps, building 5 and 100/101.
25. How many elevators per building Elevators are not part of this contract.
26. Who is responsible for the elevator contractor Elevators are not part of this contract.
27. Is there a site visit See answer to question 2.
28. Who is responsible for monitoring Monitoring is covered under another separate contract.
29. What are the due dates for the annual inspection for each building There is already a yearly schedule in place which must remain the same.
Version 2 - 10/22/24
30. Model of the FACP Notifier 75%, Simplex 20% and Edwards 5%
31. Do they have POTS or Cellular Pots
32. Last 5 Year completed Sprinkler/Standpipe Not covered under this contract. Tested under a separate contract.
33. Fire Hydrant count Not covered in this contract.
34. Do they have AS-BUILTS Yes for the primary buildings only.
35. How many Backflows Not covered in this contract.
36. How many PIV’S Approximately 55 that are monitored.
37. How Many FDC’s Waffer or Quick Check
38. How many pull stations Approximately 874
39. How many Booster panels Approximately 12
40. How many Duct Detectors Approximately 536
Control Panel Replacement and Emergency Services:
a. Section 4.1.4 mentions the replacement of control panels, which appears to go beyond standard service plans for inspection, testing, and maintenance. Could you kindly clarify the government's intent regarding the inclusion of these services? Specifically, does the government expect the contractor to replace control panels under the emergency services clause, or will this be treated as a separate service request?
41. Normal wear and tear will be covered under the contract, physical damage caused for any reason will be treated as a separate expense to the government.
42. Battery Replacement:
a. Will the replacement of fire alarm panel system batteries be included as part of this project? Yes
b. Additionally, within the Palo Alto site, it is mentioned that an Edwards system is installed to monitor a carbon monoxide system, which requires the annual replacement of detector batteries. Could the government provide details on the quantity and type of batteries required for these detectors to ensure accurate pricing? Batteries are CR123A which are not covered under this contract. The Electronics Shop replaces those batteries.
43. Multi-Year NFPA Inspections:
a. We did not observe any mention of multi-year inspections as required by NFPA (e.g., 5-year internal obstruction testing, 3-year dry trip tests, 6-year damper inspections). Does the government intend to include these multi-year inspections, or are they excluded from the current scope of work? Excluded
44. Design Assessment Services:
a. Section 9.0 refers to design assessment services. Could the government elaborate on the scope of these services? Specifically, are these assessments meant to involve reviewing proposed designs for potential fail points and offering recommendations, or is there a more comprehensive role expected from the contractor? Not covered under this contract.
45. Existing Deficiencies:
a. Given that the contractor is required to maintain a clean fire alarm system, can the government provide a list of any existing deficiencies at the facilities, if applicable? This would allow us to assess the current system status and factor in any required corrective actions in our proposal. All existing deficiencies will be the responsibility of the current Fire Alarm Testing company and will be noted by the Electronics Shop as such. The new testing company will not be responsible.
46. Water Containment for Fire Sprinkler Testing:
a. Section 5.3 mentions the containment of water during sprinkler testing. Could the government provide further guidance on the intent and acceptable methods for water containment during these tests? Additionally, are there any past use cases or examples of containment solutions that have been deemed acceptable by the government? Water is either received by a drain or released on the street.
Version 3 - 10/29/24
47. The RFI already states that the Fire Alarm repairs caused by normal wear and tear will be included in the bid. Will the Sprinkler system repairs due to normal wear and tear be included in this bid as well?
Yes, but most sprinkler repairs are due to accidental bumping. Physical damage to sprinklers will be treated as extra and outside the contract.
48. There is a bar code system already in place at these locations in the bid. Will the awarded company be required to scan these devices during the testing of each device and if so, will we be given access to this system to include the scanning devices? If we are not capable of scanning these devices and need to record the device address’ and bar codes on the inspection reports, will this information suffice?
The bar codes belong to the VA. The bar codes can be used. You must supply your own scanning device.
TO CONFIRM THIS IS AN SDVOSB SET ASIDE – NAICS CODE USED 561621
| *= Required Field |
| Amendment to a Previous Combined Solicitation |
Page 1 of
Amendment to a Previous Combined Solicitation
File details come from the government source that posted it. Updated .