36C26119Q0202-025.pdf
PDF 827 KB Posted
- Solicitation number
- 36C26119Q0202
About this file
36C26119Q0202 21 Drawing 7 Power and Security Plan @.pdf
View the file
Other files
Show all 37
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
1. ALL CABLE TERMINATIONS TO MAINTAIN TWIST OF INDIVIDUAL PAIRS TO WITHIN 1/2" OR LESS OF FINAL
TERMINATION.
2. WIRE AND CABLE SHEATH SHALL BE MAINTAINED TO FINAL TERMINATION.
3. ALL WIRES AND CABLES SHALL BE LABELED WITHIN 6�1/2" OF FINAL TERMINATION.
4. ALL LABELS SHALL BE MACHINE PRINTED OR STENCILED. NO HAND LETTERED LABELS SHALL BE USED.
5. ALL SECURITY DEVICES SHALL BE SECURELY MOUNTED PLUMB & STRAIGHT TO WALLS, FLOORS, OR
RACKS PER THE MANUFACTURER'S RECOMMENDED MOUNTING PRACTICE.
6. ALL CABLES SHALL BE PLENUM RATED WHERE REQUIRED.
7. NOTIFY OWNER'S REPRESENTITIVES OF ANY DISCREPANCIES BETWEEN THE EXISTING CONDITIONS AND
THE SECURITY DRAWINGS. OBTAIN CLARIFICATION BEFORE PROCEEDING WITH WORK.
8. COORDINATE WITH ELECTRICAL CONTRACTOR FOR SECURITY DEVICE AND CONTROL PANEL ELECTRICAL
POWER REQUIREMENTS.
9. PRIOR TO THE COMMENCEMENT OF INSTALLATION OF ANY ELEMENTS OF THE SECURITY SYSTEMS, THE SECURITY CONTRACTOR WILL MEET WITH OWNER'S REPRESENTATIVES AND SUBMIT FOR APPROVAL INSTALLATION DETAILS INCLUDING DEVICE PLACEMENT, CABLE ROUTING, WORK SCHEDULING, MATERIALS
DELIVERY, AND ANY OTHER DETAILS PERTINENT TO THE WORK.
10. ALL WIRING, CABLING, SYSTEM DEVICES, AND SYSTEM CONTROL SHALL BE INSTALLED IN COMPLIANCE WITH ALL CODE REQUIREMENTS AND MANUFACTURER'S INSTRUCTIONS AND PRACTICES UNLESS WRITTEN
DIRECTION TO THE CONTRARY IS PROVIDED.
11. ALL WIRING AND CABLING RUNS IN CEILING AREAS WHERE CABLE TRAYS OR OTHER IS NOT SPECIFIED, SHALL BE PROPERLY SUPPORTED WITH SIMILAR SUPPORT OR WITH THE USE OF J�HOOKS AT 5'�0" INTERVALS ABOVE CEILING TILES. DO NOT OVERFILL, QUANTITY OF CABLES SHALL BE IN MANUFACTURER INSTRUCTIONS.
SECURITY NOTES
A � AMPERS
AC � ABOVE CEILING
AFF � ABOVE FINISHED FLOOR
AWG � AMERICAN WIRE GAUGE
C � CONDUIT
CAT � CATALOG
CB � CIRCUIT BREAKER
CCTV � CLOSED CIRCUIT TELEVISION
CKT � CIRCUIT
C/L � CENTER LINE
CLG � CEILING
COND � CONDUCTOR
CU � COPPER
DVR � DIGITAL VIDEO RECORDER
DWG � DRAWING
EC � EMPTY CONDUIT
EM � EMERGENCY
EX � EXISTING
FA � FIRE ALARM
FACP � FIRE ALARM CONTROL PANEL
G � GROUND
HC � HUNG CEILING
HZ � HERTZ
IDF � INTERMEDIATE DISTRIBUTION FRAME
JB � JUNCTION BOX
LV � LOW VOLTAGE
ABBREVIATIONS
RISER POWER (EMERGENCY CIRCUIT)
ELECTRICAL CONTRACTOR TO PROVIDE A HARD WIRED CONNECTION TO A 120VAC 20A
EMERGENCY CIRCUIT DEDICATED TO SECURITY IN EACH RISER LOCATION WITHIN A 4" X
4" BOX SURFACE MOUNTED 18" A.F.F. WITH WIRE ENDS TERMINATED AND INSULATED
WITH WIRE NUTS
RISER POWER (NON�EMERGENCY CIRCUIT)
ELECTRICAL CONTRACTOR TO PROVIDE A HARD WIRED CONNECTION TO A 120VAC 20A
NON�EMERGENCY CIRCUIT DEDICATED TO SECURITY IN EACH RISER LOCATION WITHIN A
4" X 4" BOX SURFACE MOUNTED 18" A.F.F. WITH WIRE ENDS TERMINATED AND INSULATED
WITH WIRE NUTS
SECURITY CONTROL/EQUIPMENT ROOM POWER (UPS CIRCUIT)
ELECTRICAL CONTRACTOR TO PROVIDE A HARD WIRED CONNECTION TO A 120VAC 20A
UNINTERRUPTIBLE POWER CIRCUIT DEDICATED TO SECURITY WITHIN A 4" X 4" BOX
SURFACE MOUNTED BELOW THE FLOOR UNDER THE CONSOLE/RACK WITH WIRE ENDS
TERMINATED AND INSULATED WITH WIRE NUTS.
MAGNOTOMETER/X�RAY SCANNER POWER (EMERGENCY CIRCUIT)
ELECTRICAL CONTRACTOR SHALL PROVIDE AN UN�SWITCHED DUPLEX OUTLET
CONNECTED TO A 120VAC 20A EMERGENCY CIRCUIT DEDICATED TO SECURITY. THE
OUTLET SHALL BE FLUSH MOUNTED IN THE FLOOR.
EXTERIOR CAMERA POWER (EMERGENCY CIRCUIT)
ELECTRICAL CONTRACTOR SHALL PROVIDE A HARD WIRED CONNECTION TO A 120VAC
20A EMERGENCY CIRCUIT DEDICATED TO SECURITY. THE CIRCUIT CONNECTION SHALL
BE PROVIDED WITHIN A 4" X 4" BOX MOUNTED ABOVE ACCESSIBLE CEILING ON INTERIOR
OF BUILDING WITH WIRE ENDS TERMINATED INSULATED WITH WIRE NUTS. MULTIPLE
CONNECTIONS CAN BE BRANCHED OFF THIS CIRCUIT FOR ADDITIONAL CAMERAS BUT
SHALL NOT EXCEED 15 CONNECTIONS TOTAL. EACH CAMERA'S ACTUAL LOAD SHALL BE
1A AT 120VAC.
POLE MOUNTED CAMERA POWER (EMERGENCY CIRCUIT)
ELECTRICAL CONTRACTOR SHALL PROVIDE A HARD WIRED CONNECTION TO A 120VAC
20A EMERGENCY CIRCUIT DEDICATED TO SECURITY PROVIDED WITHIN A NEMA 4X
ENCLOSURE MOUNTED AT THE BASE OF THE POLE WITH WIRE ENDS TERMINATED AND
INSULATED WITH WIRE NUTS. MULTIPLE CONNECTIONS CAN BE BRANCHED OFF THIS
CIRCUIT FOR ADDITIONAL CAMERAS BUT SHALL NOT EXCEED 15 CONNECTIONS TOTAL.
EACH CAMERA'S ACTUAL LOAD SHALL BE 1A AT 120VAC.
DELAYED EXIT DEVICE POWER (NON�EMERGENCY CIRCUIT)
ELECTRICAL CONTRACTOR SHALL PROVIDE A HARD WIRED CONNECTION TO A 120VAC
20A NON�EMERGENCY CIRCUIT DEDICATED TO SECURITY AT DOORS UTILIZING DELAYED
EXIT DEVICES PROVIDED WITHIN A 4" X 4" BOX MOUNTED ABOVE ACCESSIBLE CEILING
ADJACENT TO THE DOOR WITH WIRE ENDS TERMINATED AND INSULATED WITH WIRE
NUTS.
ELECTRIC EXIT DEVICE POWER (EMERGENCY CIRCUIT)
ELECTRICAL CONTRACTOR SHALL PROVIDE A HARD WIRED CONNECTION TO A 120VAC
20A EMERGENCY CIRCUIT DEDICATED TO SECURITY AT DOORS UTILIZING ELECTRIC EXIT
DEVICES PROVIDED WITHIN A 4" X 4" BOX MOUNTED ABOVE ACCESSIBLE CEILING
ADJACENT TO THE DOOR WITH WIRE ENDS TERMINATED AND INSULATED WITH WIRE
NUTS. MULTIPLE CONNECTIONS CAN BE BRANCHED OFF THIS CIRCUIT FOR ADDITIONAL
ELECTRIC EXIT DEVICES BUT SHALL NOT EXCEED 10 CONNECTIONS TOTAL. EACH
DEVICE'S ACTUAL LOAD SHALL BE 1.5A AT 120VAC.
SITE POWER(NON�EMERGENCY CIRCUIT)
ELECTRICAL CONTRACTOR SHALL PROVIDE A HARD WIRED CONNECTION TO A 120VAC
20A NON�EMERGENCY CIRCUIT DEDICATED TO SECURITY WITHIN A NEMA 4X ENCLOSURE
WITH WIRE ENDS TERMINATED AND INSULATED WITH WIRE NUTS
SECURITY CONVENIENCE POWER (NON�EMERGENCY CIRCUIT)
ELECTRICAL CONTRACTOR SHALL PROVIDE AN UN�SWITCHED DUPLEX OUTLET
CONNECTED TO A 120VAC 20A NON�EMERGENCY CIRCUIT PROVIDED FLUSH IN WALL 18"
A.F.F.
ELECTRICAL NOTES
1. DRAWINGS ARE NOT TO BE USED FOR ARCHITECTURAL OR ENGINEERING PURPOSES. THE SECURITY
DRAWINGS SHOULD ONLY BE USED FOR SECURITY SYSTEMS INSTALLATION AND COORDINATION.
2. ALL MOUNTING SPECIFICS SHALL BE AS INDICATED IN THE LEGEND UNLESS OTHERWISE NOTED IN THE SECURITY DRAWINGS. MOUNTING CONDITIONS IDENTIFIED ON THE SECURITY DRAWINGS SHALL TAKE
PRECEDENCE OVER THE LEGEND DESCRIPTIONS.
3. VERIFY AND COORDINATE THE EXACT MOUNTING LOCATION OF ALL DEVICES PRIOR TO INSTALLATION.
4. THE MOUNTING HEIGHTS ARE TO THE CENTERLINE OF THE DEVICE UNLESS OTHERWISE NOTED.
5. THE SECURITY CONTRACTOR SHALL RESTORE CEILINGS AND WALLS AND ANY OTHER SURFACES AFFECTED BY HIS WORK WITH LIKE MATERIALS TO MATCH EXISTING CONSTRUCTION UPON COMPLETION OF
HIS WORK.
6. FIRE STOPPING OF ALL PENETRATIONS SHALL BE PROVIDED BY THE SECURITY CONTRACTOR AS
REQUIRED BY CODE.
7. ALL DEVICES, WIRING, TERMINATIONS, AND OTHER REQUIRED ROUGH�IN NOT DESIGNATED "BY
OTHERS" ARE TO BE PROVIDED BY THE SECURITY CONTRACTOR.
8. CONDUIT, JUNCTION BOXES AND 120 VAC POWER TO BE PROVIDED BY ELECTRICAL CONTRACTOR.
GENERAL NOTES
SECURITY � EQUIPMENT SYMBOL LEGEND
ACCESS CONTROL PANEL
ACCESS FIELD PANEL
ACCESS CONTROL SERVER
ANNUNCIATOR
AUTOMATIC DOOR OPENER
INTERFACE (BY OTHERS)
ALARM PANEL
CCTV CONTROLLER
CCTV DECODER
DIGITAL ALARM PANEL
DOOR RELEASE BUTTON
DIGITAL VIDEO RECORDER
EMERGENCY CALL BUTTON
ELEVATOR CONTROL PANEL
GUEST CARD READER
CCTV ENCODER
GUARD TOUR POINT
GLASS BREAK SENSOR
HEAD END MONITORING LOCATION
ALARM KEYPAD
FIRE RELAY (FOR LOCK RELEASE)
LOCAL ALARM
MEDICAL ALERT
MOTION DETECTOR
MOTION DETECTOR 360 = 360 DEGREE
LR = LONG RANGE
CCTV MONITOR
CCTV VIDEO MULTIPLEXER
NETWORK VIDEO RECORDER
PANIC BUTTON P = PANIC (U.O.N)
F = FOOT ALARM
SECURITY BADGE PRINTER
SIREN (INTRUSION ALARM, ACCESS CONTROL)
VIDEO BADGING STATION
WINDOW CONTACT
WORKSTATION
SECURITY RISER LOCATION
LOCK POWER SUPPLY
CAMERA POWER SUPPLY
SECURITY � CAMERA MOUNTING TYPES
SECURITY � DOOR DEVICE SYMBOL LEGEND
ACCESS CONTROL
DOOR CONTACT
TRANSFER HINGE
ELECTRIC LOCK
�WITH INTERGAL
REQUEST TO EXIT
DEVICE
ELECTRIFIED EXIT
DEVICE � WITH
INTEGRAL REQUEST
ELECTRIC STRIKE
MAGNETIC LOCK
REQUEST TO EXIT
INTERCOMM
P = PROXIMITY
M = MAGNETIC SWIPE
K = KEYPAD
B = BIOMETRIC
R = RFID
S = KEY SWITCH
V = VEHICLE
R = RECESSED
S = SURFACE MOUNT
F = FAIL SAFE
S = FAIL SECURE
F = FAIL SAFE
S = FAIL SECURE
F = FAIL SAFE
S = FAIL SECURE
M = MOTION DETECTOR
P = PUSH BUTTON
M = MASTER�STATION
S = SUB�STATION
DEVICE
DEVICE TYPE
DEVICE QTY
DEVICE TYPE
FHD = FIZED HD CAMERA
FIX = FIXED CAMERA
PTZ = PAN/TILT/ZOOM/CAMERA
xxx xx�xxx�xx
DEVICE NUMBER
LEVEL
DEVICE TYPE
AC = ACCESS CONTROL
CAM = CCTV CAMERA
IC = INTERCOM DEVICE
IN = INTRUSION DEVICE
MAX � MAXIMUM
MDF � MAIN DISTRIBUTION FRAME
MER � MECHANICAL EQUIPMENT ROOM
MIN � MINIMUM
MTD � MOUNTED
MTG � MOUNTING
N � NEUTRAL
NC � NORMALLY CLOSED
NIC � NOT IN CONTRACT
NO � NORMALLY OPEN
No. � NUMBER
NTS � NOT TO SCALE
PA � PUBLIC ADDRESS
PNL � PANEL
POE � POWER OVER ETHERNET
PTZ � PAN/TILT/ZOOM
RM � ROOM
STP � SHIELDED TWISTED PAIR
XFRM � TRANSFORMER
TEL � TELECOMMUNICATIONS
TLR � TIME LAPSE RECORDER
TS � TAMPER SWITCH
TTB � TELECOMMUNICATIONS TERMINAL BOARD
TTC � TELECOMMUNICATIONS TERMINAL CABINET
TV � TELEVISION
TYP � TYPICAL
UON � UNLESS OTHERWISE NOTED
UPS � UNINTERRUPTIBLE POWER SUPPLY
UTP � UNSHIELDED TWISTED PAIR
V � VOLTS
VA � VOLT�AMPERES
VM � VOLTIMETER
VP � VAPER PROOF
W � WATTS
WP � WATERPROOF
WT � WATER TIGHT
F = FAIL SAFE
S = FAIL SECURE
SECURITY � DEVICE SYMBOL / TAG LEGEND
ACP
AFP
ACS
AN
AO
AP
CCTV
DE
GCR
EN
GT
GB
HE
DVR
ECB
ECP
DR
1 P
KP
K
LA
MON
MUX
NVR
WC
WS
SR
XLP
XCP
SBR
SI
VBS
MD
PB
1 P
MD
MA
AC
1 P
DC
1 R
EL
1 F
ES
1 F
ML
1 F
TH
RX
1 M
VI
1 S
IC
1 S
EE
1 F
DAP
XX
WALL MOUNT
INSIDE CORNER MOUNT
OUTSIDE CORNER MOUNT
CEILING MOUNT
SHEN MILSOM WILKE
San Francisco, CA 94105
Fax: 415�391�0171 Tel: 415�391�7610
33 New Montgomery Street
201 Mission Street, Suite 2400, San Francisco, California 94105 415.243.4170 on e� qu ar te r in ch o ne fo ot on e� ei gh th in ch o ne fo ot
Revisions
8 4
Date on e� ha lf in ch o ne fo ot th re e� ei gh th s in ch o ne fo ot th re e� qu ar te rs in ch o ne fo ot
Building Number:
Approved: Project Director
Drawing Title Project Title
Date
F
E
D on e an d on e� ha lf in ch es o ne fo ot on e in ch o ne fo ot th re e in ch es o ne fo ot
1 2 3 4 5 6 7 8 9
C
B
A
Location
Checked Drawn
Drawing No.
VA Project Number:
CONSULTANTS: ARCHITECT/ENGINEERS:
Baltimore ■ Boston ■ Buffalo ■ Calgary ■ Chicago Houston ■ Los Angeles ■ Mumbai ■ New York ■ Phoenix
St. Louis ■ San Francisco ■ Shanghai ■ Toronto Vancouver ■ Victoria ■ Washington DC
F
E
D
C
B
A
1 2 3 4 5 6 7 8 9 10
GENERAL NOTES
KEY NOTES
LEGEND
Veterans Affairs Palo Alto Heath Care System 3801 Miranda Ave,Palo Alto, CA 94304
640�385
Seals and Signatures
SC0000
SECURITY GENERAL NOTES,
ABBREVIATIONS, SYMBOLS, AND
DRAWING LIST
Approver
BB RMJUNE 14, 2013
VA SIMULATION CENTER
ISSUE FOR BID
SECURITY DRAWING LIST
SC0000 SECURITY GENERAL NOTES, ABBREVIATIONS, SYMBOLS, AND DRAWING LIST
SC0201 SECURITY LEVEL 1 FLOOR PLAN
SC0202 SECURITY LEVEL 2 AND ROOF PLAN
SC0300 SECURITY ENLARGED PLANS AND ELEVATIONS
SC0400 SECURITY RISER DIAGRAM
SC0500 SECURITY DETAILS
vhapalvigils Typewritten Text For reference only Drawing from previous project Security Cameras are not in Scope only installation of card readers, power, and communications to form a complete card reader system.
vhapallappir Snapshot
UP
UP
UP
1 2 3
A
B
C
D
E
F
G
(E) EDUCATION CENTER(N) SIMULATION CENTER
(E) EDUCATION CENTER(N) SIMULATION CENTER
LARGE SIMULATION
B152
STORAGE
B154
CONTROL
B155
PATIENT ROOM
(SHELL)
B156
PATIENT ROOM
B157
CONTROL
B158
PATIENT ROOM
B159
DEBRIEFING
ROOM�2
B160
DEBRIEFING
ROOM�1
B151
ANTE ROOM
B153
ELECT
B165
MECHANICAL
B176
PREP/STORAGE
B172
DEBRIEFING
ROOM�3
B174
STORAGE
B168
CLINIC ROOM,
B173
LEARNER
SEQUESTRATION
B170
TOILET, FEMALE
B175
AV RACK ROOM
B164
WET AND DRY
UTILITY
B167
MEDICAL GAS
STORAGE
B163
LOBBY
A100
2.6
RECEPTION
B171
HAC
B177
TOILET, MALE
B161
CORRIDOR
C�10
CORRDIOR
C�11
1.7
OFFICE, SHARED
B166
D.1
B153
B152A
B155A
B158
B156
B152B
B157
B159
B167
B168B
B173
B176
B174
B177
B170B
B172
B175
B170A
B152C
B B
B171A
B164
B168A
C�10B
B161
C�10A
C�11A
B166
B163
B165
B160
C�11B
A100A
B151
FLOOR LINE
ABOVE
FLOOR LINE
ABOVE
B B
A100B
ALIGN
C D E
B.3
B
C.7
6.8
4.8
A.9
1.5
2.5
MULTI�PURPOSE
CLASS ROOM
ELEVATOR
MACHINE RM
ELEC
IRMS
AUDITORIUM
STAIR
S�1
WOMENS
MENS
ELEVATOR
CORRIDOR
C�4
HALLWAY
C�3
HAC / SPRINKLER
PREFUNCTION
C�2
STAIR
S�2
HALLWAY
C�5
STORAGE
STORAGE
STORAGE
HAC/STORAGE
AUDITORIUM
DC
1 R
DC
2 R
AC
1 P
AO
PTZ
AC
1 P
DC
1 R
EL
1 F
DC
1 R
EL
1 F
AC
1 P
DC
1 R
PTZ
DC
2 R
AO
EL
1 F
AC
1 P
SC0300
SC0500
SC0500
SC0500
SC0500
SC0500
SC0500
SC0500
SR
EL
1 F
AC
1 P
SC0500
EL
1 F
1. ALL EQUIPMENT TO BE PROVIDED IN
THE FUTURE. ONLY PROVIDE
INFRASTRUCTURE (POWER, CONDUIT,
BACKBOXES, ETC.) AS INDICATED ON
SHEET SC0500.
SHEN MILSOM WILKE
San Francisco, CA 94105
Fax: 415�391�0171 Tel: 415�391�7610
33 New Montgomery Street
201 Mission Street, Suite 2400, San Francisco, California 94105 415.243.4170 on e� qu ar te r in ch o ne fo ot on e� ei gh th in ch o ne fo ot
Revisions
8 4
Date on e� ha lf in ch o ne fo ot th re e� ei gh th s in ch o ne fo ot th re e� qu ar te rs in ch o ne fo ot
Building Number:
Approved: Project Director
Drawing Title Project Title
Date
F
E
D on e an d on e� ha lf in ch es o ne fo ot on e in ch o ne fo ot th re e in ch es o ne fo ot
1 2 3 4 5 6 7 8 9
C
B
A
Location
Checked Drawn
Drawing No.
VA Project Number:
CONSULTANTS: ARCHITECT/ENGINEERS:
Baltimore ■ Boston ■ Buffalo ■ Calgary ■ Chicago Houston ■ Los Angeles ■ Mumbai ■ New York ■ Phoenix
St. Louis ■ San Francisco ■ Shanghai ■ Toronto Vancouver ■ Victoria ■ Washington DC
F
E
D
C
B
A
1 2 3 4 5 6 7 8 9 10
GENERAL NOTES
KEY NOTES
PROJECT
NORTH
LEGEND
Veterans Affairs Palo Alto Heath Care System 3801 Miranda Ave,Palo Alto, CA 94304
640�385
Seals and Signatures
TRUE
NORTH
SC0201
SECURITY LEVEL 1 FLOOR PLAN
Approver
BB RMJUNE 14, 2013
VA SIMULATION CENTER
ISSUE FOR BID
1/8" = 1'�0"
SECURITY LEVEL 1 FLOOR PLAN
vhapalvigils Typewritten Text Security Cameras are not in Scope vhapalvigils Typewritten Text For reference only Drawing from previous project Security Cameras are not in Scope only installation of card readers, power, and communications to form a complete card reader system.
vhapalvigils Callout Provide Card Reader vhapalvigils Callout Provide Card Reader vhapalvigils Callout Provide Card Reader vhapalvigils Callout Provide Card Reader vhapalvigils Callout Provide Card Reader vhapalvigils Callout Provide Card Reader
FLOOR SLAB
FLOOR SLAB
WIRE THROUGH
(TYPICAL)
NETWORK
CONNECTION
BY TELECOM
CONTRACTOR
3/4" FIRE RATED
PLYWOOD
BACKBOARD
NOTE:
4'X8' WALL FIELD SECTION RESERVED FOR FUTURE SECURITY EQUIPMENT
LOCATED WITHIN EXISTING IRMS (120) ROOM OF THE EDUCATION CENTER.
ELECTRICAL CONTRACTOR TO
PROVIDE A HARD WIRED
CONNECTION TO A 120VAC 20A
EMERGENCY CIRCUIT DEDICATED TO
SECURITY IN EACH RISER LOCATION
WITHIN A 4"X4" BOX SURFACE
MOUNTED 18" A.F.F. WITH WIRE ENDS
TERMINATED AND INSULATED WITH
WIRE NUTS
D
C.7
IRMS
SECURITY WALL FIELD
SEE DETAIL 2
SHEN MILSOM WILKE
San Francisco, CA 94105
Fax: 415339130171 Tel: 415339137610
33 New Montgomery Street
201 Mission Street, Suite 2400, San Francisco, California 94105 415.243.4170 on e� qu ar te r in ch o ne fo ot on e� ei gh th in ch o ne fo ot
Revisions
8 4
Date on e� ha lf in ch o ne fo ot th re e� ei gh th s in ch o ne fo ot th re e� qu ar te rs in ch o ne fo ot
Building Number:
Approved: Project Director
Drawing Title Project Title
Date
F
E
D on e an d on e� ha lf in ch es o ne fo ot on e in ch o ne fo ot th re e in ch es o ne fo ot
1 2 3 4 5 6 7 8 9
C
B
A
Location
Checked Drawn
Drawing No.
VA Project Number:
CONSULTANTS: ARCHITECT/ENGINEERS:
Baltimore ■ Boston ■ Buffalo ■ Calgary ■ Chicago Houston ■ Los Angeles ■ Mumbai ■ New York ■ Phoenix
St. Louis ■ San Francisco ■ Shanghai ■ Toronto Vancouver ■ Victoria ■ Washington DC
F
E
D
C
B
A
1 2 3 4 5 6 7 8 9 10
GENERAL NOTES
KEY NOTES
LEGEND
Veterans Affairs Palo Alto Heath Care System 3801 Miranda Ave,Palo Alto, CA 94304
6403385
Seals and Signatures
SC0300
SECURITY ENLARGED PLANS AND
ELEVATIONS
Approver
BB RMJUNE 14, 2013
VA SIMULATION CENTER
ISSUE FOR BID 3/4" = 1'30"
SECURITY EQUIPMENT ELEVATION (TYPICAL)
1/2" = 1'30"
IRMS 120 FLOOR PLAN LAYOUT
vhapalvigils Typewritten Text For reference only Drawing from previous project Security Cameras are not in Scope only installation of card readers, power, and communications to form a complete card reader system.
J
FIX
J
TYPICAL
OF 1
TO SECURITY RISER LOCATION
LOCATED IN EXISTING IRMS (120) ROOM
OF THE EDUCATION CENTER.
LEVEL 02
LEVEL 01
J
PTZ
J
TYPICAL
OF 2
J
F
TYPICAL
OF 1
DC
1 R
J
G,F
TYPICAL
OF 2
DC
2 R
AC
1 P
FD
EL
1 F
TH
J
G,F
TYPICAL
OF 3
DC
1 R
AC
1 P
FD
EL
1 F
TH
TO SECURITY RISER LOCATION
LOCATED IN EXISTING IRMS (120) ROOM
OF THE EDUCATION CENTER.
1. ALL EQUIPMENT TO BE PROVIDED
IN THE FUTURE. ONLY PROVIDE
INFRASTRUCTURE (POWER, CONDUIT,
BACKBOXES, ETC.) AS INDICATED ON
SHEET SC0500.
SECURITY CABLE LEGEND
WIRE TAG DEVICE/SYSTEM CONNECTIONS GUAGE (AWG) NO. OF PAIRS SHIELDED CABLE TYPE MAX. NOTES:
A CCTV VIDEO (COAXIAL) 18 � RG/6U SOLID 1200' OR APPROVED EQUAL
B CCTV VIDEO (COAXIAL) 20 � RG/59U SOLID 850' OR APPROVED EQUAL
C CCTV VIDEO (COAXIAL) 22 � RG/59U STRANDED 850' OR APPROVED EQUAL
D DATA (CARD READER) 24 3 YES 500' OR APPROVED EQUAL
E CONTROL, SWITCHING 22/18 3 COND. NO OR APPROVED EQUAL
F 22 4 COND. OR APPROVED EQUAL
G POWER (24V AC/DC) 18 1 OR APPROVED EQUAL
H POWER/CONTROL 18 2 OR APPROVED EQUAL
J COMMUNICATIONS (DATA) 24 4 UTP/CAT6 SOLID 295' OR APPROVED EQUAL
K 24 2 YES 4000' OR APPROVED EQUAL
L 22 2 YES SOLID 50' OR APPROVED EQUAL
M 20/18 � RG/59U SOLID 1200' OR APPROVED EQUAL
CONTROL, SWITCHING
COMMUNICATIONS (RS�485)
COMMUNICATIONS (RS�232)
VIDEO & POWER (SIAMESE)
NO
NO
NO
STRANDED
STRANDED
STRANDED
STRANDED
STRANDED
STRANDED
500'
500'
500'
500'
SHEN MILSOM WILKE
San Francisco, CA 94105
Fax: 415�391�0171 Tel: 415�391�7610
33 New Montgomery Street
201 Mission Street, Suite 2400, San Francisco, California 94105 415.243.4170 on e� qu ar te r in ch o ne fo ot on e� ei gh th in ch o ne fo ot
Revisions
8 4
Date on e� ha lf in ch o ne fo ot th re e� ei gh th s in ch o ne fo ot th re e� qu ar te rs in ch o ne fo ot
Building Number:
Approved: Project Director
Drawing Title Project Title
Date
F
E
D on e an d on e� ha lf in ch es o ne fo ot on e in ch o ne fo ot th re e in ch es o ne fo ot
1 2 3 4 5 6 7 8 9
C
B
A
Location
Checked Drawn
Drawing No.
VA Project Number:
CONSULTANTS: ARCHITECT/ENGINEERS:
Baltimore ■ Boston ■ Buffalo ■ Calgary ■ Chicago Houston ■ Los Angeles ■ Mumbai ■ New York ■ Phoenix
St. Louis ■ San Francisco ■ Shanghai ■ Toronto Vancouver ■ Victoria ■ Washington DC
F
E
D
C
B
A
1 2 3 4 5 6 7 8 9 10
GENERAL NOTES
KEY NOTES
LEGEND
Veterans Affairs Palo Alto Heath Care System 3801 Miranda Ave,Palo Alto, CA 94304
640�385
Seals and Signatures
SC0400
SECURITY RISER DIAGRAM
Approver
BB RMJUNE 14, 2013
VA SIMULATION CENTER
ISSUE FOR BID
NTS
SECURITY RISER DIAGRAM
vhapalvigils Typewritten Text Security Cameras are not in Scope
FINISHED FLOOR
FINISHED CEILING
CEILING SLAB
JB
DETAIL NOTES:
1. DOOR POSITION SWITCH
2. ELECTRICAL CONTRACTOR TO PROVIDE 4" X 4" X 2�1/8"DEEP JUNCTION BOX ABOVE DOOR, ABOVE
ACCESSIBLE CEILING.
3. ELECTRICAL CONTRACTOR TO PROVIDE 3/4" CONDUIT TO NEAREST SECURITY RISER LOCATION OR CABLE TRAY, WHICHEVER IS CLOSER. REFER TO TC SERIES DRAWINGS FOR ADDITIONAL INFORMATION
ON CABLE TRAY.
FINISHED FLOOR
CEILING SLAB
FINISHED CEILING
JB
DETAIL NOTES:
1. DOOR POSITION SWITCH
2. ELECTRIFIED MORTISE LOCKING DEVICE WITH INTEGRAL
REQUEST TO EXIT DEVICE, BY DOOR HARDWARE CONTRACTOR
3. CARD READER. ELECTRICAL CONTRACTOR TO PROVIDE 4" X
4" X 2�1/8" DEEP JUNCTION BOX.
4. ELECTRIC HINGE BY DOOR HARDWARE CONTRACTOR.
5. ELECTRICAL CONTRACTOR TO PROVIDE 4" X 4" X 2�1/8" DEEP
JUNCTION BOX ABOVE DOOR, ABOVE ACCESSIBLE CEILING.
# 6. ELECTRICAL CONTRACTOR TO STUB 3/4" CONDUIT OR
GREENFIELD DOWN DOOR FRAME ON THE HINGE SIDE OF THE
DOOR BACK BOX, TO JUNCTION BOX LOCATED ABOVE
ACCESSIBLE CEILING
7. ELECTRICAL CONTRACTOR TO STUB 3/4" CONDUIT WITH
DRAG LINE.
8. ELECTRICAL CONTRACTOR TO PROVIDE 3/4" CONDUIT TO
NEAREST SECURITY RISER LOCATION OR CABLE TRAY,
WHICHEVER IS CLOSER. REFER TO TC SERIES DRAWINGS FOR
ADDITIONAL INFORMATION ON CABLE TRAY.
FINISHED FLOOR
FINISHED CEILING
CEILING SLAB
JB
DETAIL NOTES:
1. DOOR POSITION SWITCH
2. ELECTRIFIED MORTISE LOCKING DEVICE WITH INTEGRAL
REQUEST TO EXIT DEVICE, BY DOOR HARDWARE CONTRACTOR
3. CARD READER. ELECTRICAL CONTRACTOR TO PROVIDE 4" X
4" X 2�1/8" DEEP JUNCTION BOX.
4. ELECTRIC HINGE BY DOOR HARDWARE CONTRACTOR.
5. ELECTRICAL CONTRACTOR TO PROVIDE 6" X 6" X 4" DEEP
JUNCTION BOX ABOVE DOOR, ABOVE ACCESSIBLE CEILING.
# 6. ELECTRICAL CONTRACTOR TO STUB 3/4" CONDUIT OR
GREENFIELD DOWN DOOR FRAME ON THE HINGE SIDE OF THE
DOOR BACK BOX, TO JUNCTION BOX LOCATED ABOVE
ACCESSIBLE CEILING
7. ELECTRICAL CONTRACTOR TO STUB 3/4" CONDUIT WITH
DRAG LINE.
8. ELECTRICAL CONTRACTOR TO PROVIDE 3/4" CONDUIT TO
NEAREST SECURITY RISER LOCATION OR CABLE TRAY,
WHICHEVER IS CLOSER. REFER TO TC SERIES DRAWINGS FOR
ADDITIONAL INFORMATION ON CABLE TRAY.
DETAIL NOTES:
1. 6"x 6"x 4" DEEP BOX MOUNTED FLUSH IN WALL BY ELECTRICAL CONTRACTOR
2. CONDUIT AND JUNCTION BOX WITH IP DATA JACK PROVIDED WITHIN TELECOMMUNICATIONS
PACKAGE. REFER TO TELECOMMUNICATION SERIES DRAWINGS FOR ADDITIONAL INFORMATION
3. CCTV CAMERA IN ENVIRONMENTAL HOUSING MOUNTED 20' MINIMUM (EXTERIORS)
4. WALL
5. CORNER MOUNT FOR CAMERA DOME
DETAIL NOTES:
1. FINISHED CEILING PER ARCHITECTURAL DRAWINGS
2. CCTV CAMERA DOME
3. NEOPRANE GASKET WEATHER SEAL ALL AROUND
4. STRUCTURAL SUPPORT BY BUILDING PER NEC
5. 2�1/2" DEEP 2 GANG BOX BY ELECTRICAL CONTRACTOR
6. CONDUIT AND JUNCTION BOX WITH IP DATA JACK PROVIDED WITHIN TELECOMMUNICATIONS PACKAGE.
REFER TO TELECOMMUNICATIONS SERIES DRAWINGS FOR ADDITIONAL INFORMATION.
7. IP JUMPER CABLE BY SECURITY CONTRACTOR
GENERAL NOTES:
1. REFER TO FLOOR PLANS FOR EXACT MOUNTING HEIGHTS
1. ALL EQUIPMENT TO BE PROVIDED
IN THE FUTURE. ONLY PROVIDE
INFRASTRUCTURE (POWER, CONDUIT,
BACKBOXES, ETC.) AS INDICATED.
SHEN MILSOM WILKE
San Francisco, CA 94105
Fax: 415�391�0171 Tel: 415�391�7610
33 New Montgomery Street
201 Mission Street, Suite 2400, San Francisco, California 94105 415.243.4170 on e� qu ar te r in ch o ne fo ot on e� ei gh th in ch o ne fo ot
Revisions
8 4
Date on e� ha lf in ch o ne fo ot th re e� ei gh th s in ch o ne fo ot th re e� qu ar te rs in ch o ne fo ot
Building Number:
Approved: Project Director
Drawing Title Project Title
Date
F
E
D on e an d on e� ha lf in ch es o ne fo ot on e in ch o ne fo ot th re e in ch es o ne fo ot
1 2 3 4 5 6 7 8 9
C
B
A
Location
Checked Drawn
Drawing No.
VA Project Number:
CONSULTANTS: ARCHITECT/ENGINEERS:
Baltimore ■ Boston ■ Buffalo ■ Calgary ■ Chicago Houston ■ Los Angeles ■ Mumbai ■ New York ■ Phoenix
St. Louis ■ San Francisco ■ Shanghai ■ Toronto Vancouver ■ Victoria ■ Washington DC
F
E
D
C
B
A
1 2 3 4 5 6 7 8 9 10
GENERAL NOTES
KEY NOTES
LEGEND
Veterans Affairs Palo Alto Heath Care System 3801 Miranda Ave,Palo Alto, CA 94304
640�385
Seals and Signatures
SC0500
SECURITY DETAILS
Approver
BB RMJUNE 14, 2013
VA SIMULATION CENTER
ISSUE FOR BID
NTS
DOOR CONTACT SINGLE DOOR
NTS
MORTISE LOCKING DEVICE, CARD READER CONFIGURATION
NTS
MORTISE LOCKING DEVICE, CARD READER CONFIGURATION
NTS
CCTV CAMERA � CORNER MOUNT
NTS
INTERIOR CEILING MOUNTED CCTV MINI�DOME IP CAMERA
vhapalvigils Typewritten Text Conduits shown have been installed by building contractor Card readers, power conductors, communication conductors, and pathway to IRMS room 120 are part of scope.
Contractor shall provide for (5) of each type of building acoustical ceiling tiles to be replaced as damaged by project work.
File details come from the government source that posted it.