36C26119Q0202-004.pdf

PDF 16 MB Posted

Attached to
Install Automatic Door Openers VA Palo Alto Health Care System
Solicitation number
36C26119Q0202
Issued by

About this file

36C26119Q0202 000 Complete Drawing Set For Bid.pdf

View the file

Other files

File Type Posted
36C26119Q0202-0002000.docx DOCX document
36C26119Q0202-0001001.pdf PDF
36C26119Q0202-0001000.docx DOCX document
36C26119Q0202-008.pdf PDF
36C26119Q0202-017.pdf PDF
36C26119Q0202-025.pdf PDF
36C26119Q0202-011.pdf PDF
36C26119Q0202-031.pdf PDF
36C26119Q0202-007.pdf PDF
36C26119Q0202-023.pdf PDF
36C26119Q0202-032.pdf PDF
36C26119Q0202-005.pdf PDF
36C26119Q0202-013.pdf PDF
36C26119Q0202-018.pdf PDF
36C26119Q0202-003.pdf PDF
36C26119Q0202-028.pdf PDF
36C26119Q0202-029.pdf PDF
36C26119Q0202-021.pdf PDF
36C26119Q0202-009.pdf PDF
36C26119Q0202-010.pdf PDF
36C26119Q0202-001.pdf PDF
36C26119Q0202-019.pdf PDF
36C26119Q0202-027.pdf PDF
36C26119Q0202-030.pdf PDF
36C26119Q0202-006.pdf PDF
36C26119Q0202-002.docx DOCX document
36C26119Q0202-034.pdf PDF
36C26119Q0202-012.pdf PDF
36C26119Q0202-033.pdf PDF
36C26119Q0202-015.pdf PDF
36C26119Q0202-014.pdf PDF
36C26119Q0202-000.docx DOCX document
36C26119Q0202-026.pdf PDF
36C26119Q0202-022.pdf PDF
36C26119Q0202-020.pdf PDF
36C26119Q0202-016.pdf PDF
36C26119Q0202-024.pdf PDF
Show all 37

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Project No. 640-18-109 Department of Veterans Affairs Install Automatic Door Openers

VA Palo Alto Health Care System (VAPAHCS) Palo Alto (PAD)

California

DRAWING PACKAGE

vhapallappir Snapshot vhapallappir Snapshot vhapallappir Snapshot vhapallappir Snapshot vhapallappir Snapshot vhapallappir Snapshot vhapallappir Snapshot vhapallappir Snapshot vhapallappir Snapshot vhapallappir Snapshot vhapallappir Snapshot vhapallappir Snapshot vhapallappir Snapshot vhapallappir Snapshot vhapallappir Snapshot vhapallappir Snapshot vhapallappir Snapshot vhapallappir Snapshot vhapallappir Snapshot vhapallappir Snapshot vhapallappir Snapshot vhapallappir Snapshot vhapallappir Snapshot vhapallappir Snapshot vhapallappir Snapshot vhapallappir Snapshot vhapallappir Snapshot vhapallappir Snapshot vhapallappir Snapshot vhapallappir Snapshot vhapallappir Snapshot vhapallappir Snapshot vhapallappir Snapshot vhapallappir Snapshot vhapallappir Snapshot vhapallappir Snapshot vhapallappir Snapshot vhapallappir Snapshot vhapallappir Snapshot vhapallappir Snapshot vhapallappir Snapshot vhapallappir Snapshot vhapallappir Snapshot vhapallappir Snapshot vhapallappir Snapshot vhapallappir Snapshot vhapallappir Snapshot vhapallappir Snapshot vhapallappir Snapshot vhapallappir Snapshot vhapallappir Snapshot vhapallappir Snapshot vhapallappir Snapshot vhapallappir Snapshot vhapallappir Snapshot vhapallappir Snapshot vhapallappir Snapshot vhapallappir Snapshot vhapallappir Snapshot vhapallappir Snapshot vhapallappir Snapshot vhapallappir Snapshot vhapallappir Snapshot vhapallappir Snapshot vhapallappir Snapshot vhapallappir Snapshot vhapallappir Snapshot vhapallappir Snapshot vhapallappir Snapshot vhapallappir Snapshot vhapallappir Snapshot vhapallappir Snapshot vhapallappir Snapshot vhapallappir Snapshot vhapallappir Snapshot vhapallappir Snapshot vhapallappir Snapshot vhapallappir Snapshot vhapallappir Snapshot vhapallappir Snapshot vhapallappir Snapshot vhapallappir Snapshot vhapallappir Snapshot vhapallappir Snapshot vhapallappir Snapshot vhapallappir Snapshot vhapallappir Snapshot vhapallappir Snapshot vhapallappir Snapshot vhapallappir Snapshot

UP

UP

A0302

C D E

B.3

B

C.7

6.8

4.8

A.9

1.5

2.5

MULTI-PURPOSE

CLASS ROOM

ELEVATOR

MACHINE RM

ELEC

IRMS

AUDITORIUM

STAIR

S-1

WOMENS

MENS

ELEVATOR

CORRIDOR

C-4

HALLWAY

C-3

HAC / SPRINKLER

PREFUNCTION

C-2

STAIR

S-2

HALLWAY

C-5

STORAGE

STORAGE

STORAGE

HAC/STORAGE

AUDITORIUM

A0301

A0301

1 2 3

A

B

C

D

E

F

G

(E) EDUCATION CENTER(N) SIMULATION CENTER

(E) EDUCATION CENTER(N) SIMULATION CENTER

LARGE SIMULATION

B152

STORAGE

B154

CONTROL

B155

PATIENT ROOM

(SHELL)

B156

PATIENT ROOM

B157

CONTROL

B158

PATIENT ROOM

B159

DEBRIEFING

ROOM-2

B160

DEBRIEFING

ROOM-1

B151

ANTE ROOM

B153

ELECT

B165

MECHANICAL

B176

PREP/STORAGE

B172

DEBRIEFING

ROOM-3

B174

STORAGE

B168

CLINIC ROOM,

B173

LEARNER

SEQUESTRATION

B170

TOILET, FEMALE

B175

AV RACK ROOM

B164

WET AND DRY

UTILITY

B167

MEDICAL GAS

STORAGE

B163

LOBBY

A100

1' - 11" 22' - 2" 10' - 0" 19' - 4" 1' - 9" 9' - 5 1/8" 17' - 11" 4' - 1"

55' - 2" 30' - 0 1/8"

/4

/8

/8

2.6

RECEPTION

B171

HAC

B177

TOILET, MALE

B161

CORRIDOR

C-10

CORRDIOR

C-11

1.7

A03022

A06031D

A0601 2B2D

1B

A0601

4A

4D

A0402

A0601

7A

A0601 1B

A06021 2

A0601

3C

3A

A06013D 1A

1C

1D

OFFICE, SHARED

B166

A03023 4

A0310

A0310

D.1

A0310

A0310

A0311

A0202

A0202

A0201

A0203

A0201

A0203

A0601

6A

A0421

A0501

A0423

A0423

R2R2 R2

L3 L3

A1

A1 A1

N2

N2

A2

A2

N1

L3

F4

1' - 0" 1' - 0"

A0421

A0422

A0421

A0423

A0422

A2A2S

R2S

A2S

L3 L3

R2

R2

M3S M3S

A2

R4

R2

R2

R2 R2

R2

R2 R2

R2

R2

A0422

R2

R2

N1

A2R2 L3

A1

A1 A1

A1

R2 A2S

L3R2

L3

R1

B153

B152A

B155A

B158

B156

B152B

B157

B159

B167

B168B

B173

B176

B174

B177

B170B

B172

B175

B170A

B152C

B B

B171A

B164

B168A

C-10B

B161

C-11A

B166

B163

B165

B160

C-11B

A100A

B151

1C

1A

FLOOR LINE

ABOVE

FLOOR LINE

ABOVE

A0203

A0601 5B

B B

CG

CG

CG

CG

CG

CG

CG

CG

CG

CG

CG

CG

A2

A100B

A0601

8A

F4

F4

T3

FEC

FEC

10" 6' - 0 3/8" 8' - 9 5/8"

3'

/4

4'

/4

7'

/8

7'

/8

1'

1"

A0423

8 1/8" 4' - 10 3/4"

3'

3'

1'

4'

/8

ALIGN

4'

3/ 4"

5'

/4

8'

1'

3'

1/ 4"

5'

/4

8'

/4

7'

/2

5'

8'

/8

2'

/4

2'

1'

1'

7'

8' - 8 5/8"

2' - 11 1/4"

2' - 7 1/2"

14' - 10 3/4" 1' - 0"

1' - 0" 1' - 8 5/8"

5' - 0 1/8"

1' - 0" 8' - 6 3/4"

2' - 6"

1'

10"

8'

1'

5'

4'

" 1'

/8

A0422

8 1/8"

1' - 6" 10"

E

Q . P

A N

E L

A0853

A0853

1' - 0" 1' - 0"

1' - 0" 1' - 0"

13' - 8 7/8"

A0853

1. ENCLOSE ALL EXPOSED DUCTS, PIPES, CONDUITS,

ETC. IN FINISHED SPACE WITH CONSTRUCTION AND

FINISH TO MATCH ADJACENT CONSTRUCTION UNO.

2. DO NOT DETERMINE DIMENSIONS AND SIZE OF THE

GRAPHIC REPRESENTATIONS SHOWN ON THE

DRAWINGS BY USING MEASURING DEVICES (DO NOT

"SCALE"). RELY ON THE NUMERIC DIMENSIONS SHOWN

ON THE DRAWINGS FOR MEASUREMENT.

3. DIMENSIONS ARE TAKEN FROM CENTERLINE OF

STRUCTURE, FACE OF CONCRETE OR FINISHED FACE

OF PARTITIONS UNO. SEE PARTITION TYPES SHEETS

(A1000 SERIES) FOR PARTITION THICKNESS AND

MATERIALS.

4. DIMENSIONS TO DOOR IS TO THE CENTERLINE OF

DOOR, TYPICAL.

5. GC SHALL PROVIDE BACKING FOR WALL MOUNTED

SHELVING (VFVI). REFER TO EQUIPMENT & FURNITURE

PLAN FOR WALL MOUNTED SHELVING LOCATION.

1 SEE PLUMBING DWGS FOR MANIFOLD

2 PROVIDE ROOM FINISHES/GAS & ELECT

OUTLETS. ONLY CASEWORK IS OMITTED

IN PATIENT ROOM # B156

3 DOOR BEING USED AS ATRIUM SMOKE CONTROL

SYSTEM MAKE-UP AIR. (TIE TO EMERGENCY

POWER)

4 DOOR BEING USED AS ATRIUM SMOKE CONTROL

SYSTEM MAKE-UP AIR. (TIE TO EMERGENCY

POWER.) REPLACE EXISTING HARDWARE &

PROVIDE NEW HARDWARE AS NEEDED.

201 Mission Street, Suite 2400, San Francisco, California 94105 415.243.4170 on e-qu ar te r i nc h on e fo ot on e-ei gh th in ch o ne fo ot

Revisions

8 4

Date on e-ha lf in ch o ne fo ot th re e-ei gh th s in ch o ne fo ot th re e-qu ar te rs in ch o ne fo ot

Building Number:

Approved: Project Director

Drawing Title Project Title

Date

F

E

D on e an d on e-ha lf in ch es o ne fo ot on e in ch o ne fo ot th re e in ch es o ne fo ot

1 2 3 4 5 6 7 8 9

C

B

A

Location

Checked Drawn

Drawing No.

VA Project Number:

CONSULTANTS: ARCHITECT/ENGINEERS:

Baltimore ■ Boston ■ Buffalo ■ Calgary ■ Chicago Houston ■ Los Angeles ■ Mumbai ■ New York ■ Phoenix

St. Louis ■ San Francisco ■ Shanghai ■ Toronto Vancouver ■ Victoria ■ Washington DC

F

E

D

C

B

A

1 2 3 4 5 6 7 8 9 10

GENERAL NOTES

KEY NOTES

PROJECT

NORTH

LEGEND

Veterans Affairs Palo Alto Heath Care System 3801 Miranda Ave,Palo Alto, CA 94304

640-385

Seals and Signatures

TRUE

NORTH

A0101

LEVEL 1 FLOOR PLAN

Approver

CW WKJUNE 14, 2013

VA SIMULATION CENTER

ISSUE FOR BID 1/8" = 1'-0"

LEVEL 01 FLOOR PLAN

VHAPALNGORY

Highlight

VHAPALNGORY

Highlight

VHAPALNGORY

Highlight

VHAPALNGORY

Highlight

VHAPALNGORY

Highlight

VHAPALNGORY

Highlight

VHAPALNGORY

Highlight

VHAPALNGORY

Highlight

VHAPALNGORY

Highlight

VHAPALNGORY

Highlight

DN

DN

A0302

C D E

B.3

B

C.7

6.8

4.8

A.9

1.5

2.5

CONFERENCE

MECH

220A

AMMS/ EMS

STORAGE

MEN

WOMEN

ROOF ACCESS

SO

200A

CONFERENCE

200C

PO

200D

PO

200E

PO

200F

PO

200G PO

200H

CONFERENCE

200I

CONFERENCE

200J

COPY/COFFEE

200K

OPEN OFFICE

HALLWAY

C-7

ELEVATOR LOBBY

C-8

SO

200B

STAIR

ELEV

ELEV

STAIR

HALLWAY

C-9

PO

230J

PO

230H

PO

230G

PO

230F

PO

230E

PO

230A

PO

230B

STORAGE

230C

OPEN OFFICE

PO

230D

A0301

A0301

1 2 3

A

B

C

D

E

F

G

(E) EDUCATION CENTER(N) SIMULATION CENTER

(E) EDUCATION CENTER(N) SIMULATION CENTER

2.61.7

A03022

A06031D 1B

A0402

A03023 4

A0310

D.1

A0310

A0311

1' - 11" 22' - 2" 10' - 0" 19' - 4" 1' - 9" 9' - 5 1/8" 17' - 11" 4' - 1"

55' - 2" 30' - 0 1/8"

/4

/8

/8

A0501

A0421

A200A

A200B

LOBBY

A200

1C

1A

10"

6"

2 EQ. PANEL

9' - 4 3/8" 10"

9"

L3

" 1

L3

L3

HIGH POINT

HIGH POINT

HIGH POINT

TYP.

2 3

2 3

TYP.

A0801

A0424

TYP.

A0424

A0301

A0426

A0425

A0425

A0425

OPP.

A0801

1' - 0 5/8"

6'

9'

/8

1' - 0"

3'

ALIGN

4'

/8

1'

8 1/8" 4' - 10 3/4"

3'

3'

2' - 4"

6"

8"

1' - 6" 10"

4 EQ. PANEL

16' - 3"

8 1/8"

1' - 9 1/2" 10"

A0853

A0853

A0853

E

Q . P

A N

E L

/8

E

Q . P

A N

E L

/8

5 EQ. PANEL

20' - 6"

/8

4'

4'

4'

4'

4'

4'

4'

4'

4'

4'

3'

/8

A0853

A0426

A0426

1' - 4"

A0421

4 TYP.

LOWER ROOF SLOPE =

1/8" OVER 1'-0"

1. ENCLOSE ALL EXPOSED DUCTS, PIPES, CONDUITS,

ETC. IN FINISHED SPACE WITH CONSTRUCTION AND

FINISH TO MATCH ADJACENT CONSTRUCTION UNO.

2. DO NOT DETERMINE DIMENSIONS AND SIZE OF THE

GRAPHIC REPRESENTATIONS SHOWN ON THE

DRAWINGS BY USING MEASURING DEVICES (DO NOT

"SCALE"). RELY ON THE NUMERIC DIMENSIONS SHOWN

ON THE DRAWINGS FOR MEASUREMENT.

3. DIMENSIONS ARE TAKEN FROM CENTERLINE OF

STRUCTURE, FACE OF CONCRETE OR FINISHED FACE

OF PARTITIONS UNO. SEE PARTITION TYPES SHEETS

(A1000 SERIES) FOR PARTITION THICKNESS AND

MATERIALS.

4. DIMENSIONS TO DOOR IS TO THE CENTERLINE OF

DOOR, TYPICAL.

5. GC SHALL PROVIDE BACKING FOR WALL MOUNTED

SHELVING (VFVI). REFER TO EQUIPMENT & FURNITURE

PLAN FOR WALL MOUNTED SHELVING LOCATION.

1 221400 COMBINED ROOF DRAIN WITH OVERFLOW

2 075419 MINIMUM 6" RIGID INSULATION TAPERED

TO DRAIN

3 075419 SINGLE PLY "COOL ROOF"

4 051200 COLUMN SPLICE EXTENSIONS FOR PHASE

2 FUTURE EXPANSION, SEE STRUCTURAL

DRAWINGS. SEE 16/A0421 FOR ROOFING DETAIL

5 074213 METAL MECHANICAL SCREEN WITH STL.

TUBE SUPPORTS

6 076200 PAINTED MTL. COPING CAP

7 076200 TWO PIECE COUNTER-FLASHING CONT.

AT PARAPET.

8 081113 HOLLOW METAL DOOR AND FRAME

PAINTED TO MATCH ADJACENT MATERIAL

9 079513 SEISMIC JOINT COVER

10 EPDM WALK PADS

11 CROSSOVER

12 EXHAUST FAN. SEE MECHANICAL DWGS

13 HATCH INDICATE RE-ROOFING FOR (N) EXHAUST

FAN INSTALLATION.

201 Mission Street, Suite 2400, San Francisco, California 94105 415.243.4170 on e-qu ar te r i nc h on e fo ot on e-ei gh th in ch o ne fo ot

Revisions

8 4

Date on e-ha lf in ch o ne fo ot th re e-ei gh th s in ch o ne fo ot th re e-qu ar te rs in ch o ne fo ot

Building Number:

Approved: Project Director

Drawing Title Project Title

Date

F

E

D on e an d on e-ha lf in ch es o ne fo ot on e in ch o ne fo ot th re e in ch es o ne fo ot

1 2 3 4 5 6 7 8 9

C

B

A

Location

Checked Drawn

Drawing No.

VA Project Number:

CONSULTANTS: ARCHITECT/ENGINEERS:

Baltimore ■ Boston ■ Buffalo ■ Calgary ■ Chicago Houston ■ Los Angeles ■ Mumbai ■ New York ■ Phoenix

St. Louis ■ San Francisco ■ Shanghai ■ Toronto Vancouver ■ Victoria ■ Washington DC

F

E

D

C

B

A

1 2 3 4 5 6 7 8 9 10

GENERAL NOTES

KEY NOTES

PROJECT

NORTH

LEGEND

Veterans Affairs Palo Alto Heath Care System 3801 Miranda Ave,Palo Alto, CA 94304

640-385

Seals and Signatures

TRUE

NORTH

A0102

LEVEL 2 FLOOR PLAN AND ROOF

PLAN

Approver

CW WKJUNE 14, 2013

VA SIMULATION CENTER

ISSUE FOR BID 1/8" = 1'-0"

LEVEL 2 FLOOR PLAN

1. ALL CABLE TERMINATIONS TO MAINTAIN TWIST OF INDIVIDUAL PAIRS TO WITHIN 1/2" OR LESS OF FINAL

TERMINATION.

2. WIRE AND CABLE SHEATH SHALL BE MAINTAINED TO FINAL TERMINATION.

3. ALL WIRES AND CABLES SHALL BE LABELED WITHIN 6�1/2" OF FINAL TERMINATION.

4. ALL LABELS SHALL BE MACHINE PRINTED OR STENCILED. NO HAND LETTERED LABELS SHALL BE USED.

5. ALL SECURITY DEVICES SHALL BE SECURELY MOUNTED PLUMB & STRAIGHT TO WALLS, FLOORS, OR

RACKS PER THE MANUFACTURER'S RECOMMENDED MOUNTING PRACTICE.

6. ALL CABLES SHALL BE PLENUM RATED WHERE REQUIRED.

7. NOTIFY OWNER'S REPRESENTITIVES OF ANY DISCREPANCIES BETWEEN THE EXISTING CONDITIONS AND

THE SECURITY DRAWINGS. OBTAIN CLARIFICATION BEFORE PROCEEDING WITH WORK.

8. COORDINATE WITH ELECTRICAL CONTRACTOR FOR SECURITY DEVICE AND CONTROL PANEL ELECTRICAL

POWER REQUIREMENTS.

9. PRIOR TO THE COMMENCEMENT OF INSTALLATION OF ANY ELEMENTS OF THE SECURITY SYSTEMS, THE SECURITY CONTRACTOR WILL MEET WITH OWNER'S REPRESENTATIVES AND SUBMIT FOR APPROVAL INSTALLATION DETAILS INCLUDING DEVICE PLACEMENT, CABLE ROUTING, WORK SCHEDULING, MATERIALS

DELIVERY, AND ANY OTHER DETAILS PERTINENT TO THE WORK.

10. ALL WIRING, CABLING, SYSTEM DEVICES, AND SYSTEM CONTROL SHALL BE INSTALLED IN COMPLIANCE WITH ALL CODE REQUIREMENTS AND MANUFACTURER'S INSTRUCTIONS AND PRACTICES UNLESS WRITTEN

DIRECTION TO THE CONTRARY IS PROVIDED.

11. ALL WIRING AND CABLING RUNS IN CEILING AREAS WHERE CABLE TRAYS OR OTHER IS NOT SPECIFIED, SHALL BE PROPERLY SUPPORTED WITH SIMILAR SUPPORT OR WITH THE USE OF J�HOOKS AT 5'�0" INTERVALS ABOVE CEILING TILES. DO NOT OVERFILL, QUANTITY OF CABLES SHALL BE IN MANUFACTURER INSTRUCTIONS.

SECURITY NOTES

A � AMPERS

AC � ABOVE CEILING

AFF � ABOVE FINISHED FLOOR

AWG � AMERICAN WIRE GAUGE

C � CONDUIT

CAT � CATALOG

CB � CIRCUIT BREAKER

CCTV � CLOSED CIRCUIT TELEVISION

CKT � CIRCUIT

C/L � CENTER LINE

CLG � CEILING

COND � CONDUCTOR

CU � COPPER

DVR � DIGITAL VIDEO RECORDER

DWG � DRAWING

EC � EMPTY CONDUIT

EM � EMERGENCY

EX � EXISTING

FA � FIRE ALARM

FACP � FIRE ALARM CONTROL PANEL

G � GROUND

HC � HUNG CEILING

HZ � HERTZ

IDF � INTERMEDIATE DISTRIBUTION FRAME

JB � JUNCTION BOX

LV � LOW VOLTAGE

ABBREVIATIONS

RISER POWER (EMERGENCY CIRCUIT)

ELECTRICAL CONTRACTOR TO PROVIDE A HARD WIRED CONNECTION TO A 120VAC 20A

EMERGENCY CIRCUIT DEDICATED TO SECURITY IN EACH RISER LOCATION WITHIN A 4" X

4" BOX SURFACE MOUNTED 18" A.F.F. WITH WIRE ENDS TERMINATED AND INSULATED

WITH WIRE NUTS

RISER POWER (NON�EMERGENCY CIRCUIT)

ELECTRICAL CONTRACTOR TO PROVIDE A HARD WIRED CONNECTION TO A 120VAC 20A

NON�EMERGENCY CIRCUIT DEDICATED TO SECURITY IN EACH RISER LOCATION WITHIN A

4" X 4" BOX SURFACE MOUNTED 18" A.F.F. WITH WIRE ENDS TERMINATED AND INSULATED

WITH WIRE NUTS

SECURITY CONTROL/EQUIPMENT ROOM POWER (UPS CIRCUIT)

ELECTRICAL CONTRACTOR TO PROVIDE A HARD WIRED CONNECTION TO A 120VAC 20A

UNINTERRUPTIBLE POWER CIRCUIT DEDICATED TO SECURITY WITHIN A 4" X 4" BOX

SURFACE MOUNTED BELOW THE FLOOR UNDER THE CONSOLE/RACK WITH WIRE ENDS

TERMINATED AND INSULATED WITH WIRE NUTS.

MAGNOTOMETER/X�RAY SCANNER POWER (EMERGENCY CIRCUIT)

ELECTRICAL CONTRACTOR SHALL PROVIDE AN UN�SWITCHED DUPLEX OUTLET

CONNECTED TO A 120VAC 20A EMERGENCY CIRCUIT DEDICATED TO SECURITY. THE

OUTLET SHALL BE FLUSH MOUNTED IN THE FLOOR.

EXTERIOR CAMERA POWER (EMERGENCY CIRCUIT)

ELECTRICAL CONTRACTOR SHALL PROVIDE A HARD WIRED CONNECTION TO A 120VAC

20A EMERGENCY CIRCUIT DEDICATED TO SECURITY. THE CIRCUIT CONNECTION SHALL

BE PROVIDED WITHIN A 4" X 4" BOX MOUNTED ABOVE ACCESSIBLE CEILING ON INTERIOR

OF BUILDING WITH WIRE ENDS TERMINATED INSULATED WITH WIRE NUTS. MULTIPLE

CONNECTIONS CAN BE BRANCHED OFF THIS CIRCUIT FOR ADDITIONAL CAMERAS BUT

SHALL NOT EXCEED 15 CONNECTIONS TOTAL. EACH CAMERA'S ACTUAL LOAD SHALL BE

1A AT 120VAC.

POLE MOUNTED CAMERA POWER (EMERGENCY CIRCUIT)

ELECTRICAL CONTRACTOR SHALL PROVIDE A HARD WIRED CONNECTION TO A 120VAC

20A EMERGENCY CIRCUIT DEDICATED TO SECURITY PROVIDED WITHIN A NEMA 4X

ENCLOSURE MOUNTED AT THE BASE OF THE POLE WITH WIRE ENDS TERMINATED AND

INSULATED WITH WIRE NUTS. MULTIPLE CONNECTIONS CAN BE BRANCHED OFF THIS

CIRCUIT FOR ADDITIONAL CAMERAS BUT SHALL NOT EXCEED 15 CONNECTIONS TOTAL.

EACH CAMERA'S ACTUAL LOAD SHALL BE 1A AT 120VAC.

DELAYED EXIT DEVICE POWER (NON�EMERGENCY CIRCUIT)

ELECTRICAL CONTRACTOR SHALL PROVIDE A HARD WIRED CONNECTION TO A 120VAC

20A NON�EMERGENCY CIRCUIT DEDICATED TO SECURITY AT DOORS UTILIZING DELAYED

EXIT DEVICES PROVIDED WITHIN A 4" X 4" BOX MOUNTED ABOVE ACCESSIBLE CEILING

ADJACENT TO THE DOOR WITH WIRE ENDS TERMINATED AND INSULATED WITH WIRE

NUTS.

ELECTRIC EXIT DEVICE POWER (EMERGENCY CIRCUIT)

ELECTRICAL CONTRACTOR SHALL PROVIDE A HARD WIRED CONNECTION TO A 120VAC

20A EMERGENCY CIRCUIT DEDICATED TO SECURITY AT DOORS UTILIZING ELECTRIC EXIT

DEVICES PROVIDED WITHIN A 4" X 4" BOX MOUNTED ABOVE ACCESSIBLE CEILING

ADJACENT TO THE DOOR WITH WIRE ENDS TERMINATED AND INSULATED WITH WIRE

NUTS. MULTIPLE CONNECTIONS CAN BE BRANCHED OFF THIS CIRCUIT FOR ADDITIONAL

ELECTRIC EXIT DEVICES BUT SHALL NOT EXCEED 10 CONNECTIONS TOTAL. EACH

DEVICE'S ACTUAL LOAD SHALL BE 1.5A AT 120VAC.

SITE POWER(NON�EMERGENCY CIRCUIT)

ELECTRICAL CONTRACTOR SHALL PROVIDE A HARD WIRED CONNECTION TO A 120VAC

20A NON�EMERGENCY CIRCUIT DEDICATED TO SECURITY WITHIN A NEMA 4X ENCLOSURE

WITH WIRE ENDS TERMINATED AND INSULATED WITH WIRE NUTS

SECURITY CONVENIENCE POWER (NON�EMERGENCY CIRCUIT)

ELECTRICAL CONTRACTOR SHALL PROVIDE AN UN�SWITCHED DUPLEX OUTLET

CONNECTED TO A 120VAC 20A NON�EMERGENCY CIRCUIT PROVIDED FLUSH IN WALL 18"

A.F.F.

ELECTRICAL NOTES

1. DRAWINGS ARE NOT TO BE USED FOR ARCHITECTURAL OR ENGINEERING PURPOSES. THE SECURITY

DRAWINGS SHOULD ONLY BE USED FOR SECURITY SYSTEMS INSTALLATION AND COORDINATION.

2. ALL MOUNTING SPECIFICS SHALL BE AS INDICATED IN THE LEGEND UNLESS OTHERWISE NOTED IN THE SECURITY DRAWINGS. MOUNTING CONDITIONS IDENTIFIED ON THE SECURITY DRAWINGS SHALL TAKE

PRECEDENCE OVER THE LEGEND DESCRIPTIONS.

3. VERIFY AND COORDINATE THE EXACT MOUNTING LOCATION OF ALL DEVICES PRIOR TO INSTALLATION.

4. THE MOUNTING HEIGHTS ARE TO THE CENTERLINE OF THE DEVICE UNLESS OTHERWISE NOTED.

5. THE SECURITY CONTRACTOR SHALL RESTORE CEILINGS AND WALLS AND ANY OTHER SURFACES AFFECTED BY HIS WORK WITH LIKE MATERIALS TO MATCH EXISTING CONSTRUCTION UPON COMPLETION OF

HIS WORK.

6. FIRE STOPPING OF ALL PENETRATIONS SHALL BE PROVIDED BY THE SECURITY CONTRACTOR AS

REQUIRED BY CODE.

7. ALL DEVICES, WIRING, TERMINATIONS, AND OTHER REQUIRED ROUGH�IN NOT DESIGNATED "BY

OTHERS" ARE TO BE PROVIDED BY THE SECURITY CONTRACTOR.

8. CONDUIT, JUNCTION BOXES AND 120 VAC POWER TO BE PROVIDED BY ELECTRICAL CONTRACTOR.

GENERAL NOTES

SECURITY � EQUIPMENT SYMBOL LEGEND

ACCESS CONTROL PANEL

ACCESS FIELD PANEL

ACCESS CONTROL SERVER

ANNUNCIATOR

AUTOMATIC DOOR OPENER

INTERFACE (BY OTHERS)

ALARM PANEL

CCTV CONTROLLER

CCTV DECODER

DIGITAL ALARM PANEL

DOOR RELEASE BUTTON

DIGITAL VIDEO RECORDER

EMERGENCY CALL BUTTON

ELEVATOR CONTROL PANEL

GUEST CARD READER

CCTV ENCODER

GUARD TOUR POINT

GLASS BREAK SENSOR

HEAD END MONITORING LOCATION

ALARM KEYPAD

FIRE RELAY (FOR LOCK RELEASE)

LOCAL ALARM

MEDICAL ALERT

MOTION DETECTOR

MOTION DETECTOR 360 = 360 DEGREE

LR = LONG RANGE

CCTV MONITOR

CCTV VIDEO MULTIPLEXER

NETWORK VIDEO RECORDER

PANIC BUTTON P = PANIC (U.O.N)

F = FOOT ALARM

SECURITY BADGE PRINTER

SIREN (INTRUSION ALARM, ACCESS CONTROL)

VIDEO BADGING STATION

WINDOW CONTACT

WORKSTATION

SECURITY RISER LOCATION

LOCK POWER SUPPLY

CAMERA POWER SUPPLY

SECURITY � CAMERA MOUNTING TYPES

SECURITY � DOOR DEVICE SYMBOL LEGEND

ACCESS CONTROL

DOOR CONTACT

TRANSFER HINGE

ELECTRIC LOCK

�WITH INTERGAL

REQUEST TO EXIT

DEVICE

ELECTRIFIED EXIT

DEVICE � WITH

INTEGRAL REQUEST

ELECTRIC STRIKE

MAGNETIC LOCK

REQUEST TO EXIT

INTERCOMM

P = PROXIMITY

M = MAGNETIC SWIPE

K = KEYPAD

B = BIOMETRIC

R = RFID

S = KEY SWITCH

V = VEHICLE

R = RECESSED

S = SURFACE MOUNT

F = FAIL SAFE

S = FAIL SECURE

F = FAIL SAFE

S = FAIL SECURE

F = FAIL SAFE

S = FAIL SECURE

M = MOTION DETECTOR

P = PUSH BUTTON

M = MASTER�STATION

S = SUB�STATION

DEVICE

DEVICE TYPE

DEVICE QTY

DEVICE TYPE

FHD = FIZED HD CAMERA

FIX = FIXED CAMERA

PTZ = PAN/TILT/ZOOM/CAMERA

xxx xx�xxx�xx

DEVICE NUMBER

LEVEL

DEVICE TYPE

AC = ACCESS CONTROL

CAM = CCTV CAMERA

IC = INTERCOM DEVICE

IN = INTRUSION DEVICE

MAX � MAXIMUM

MDF � MAIN DISTRIBUTION FRAME

MER � MECHANICAL EQUIPMENT ROOM

MIN � MINIMUM

MTD � MOUNTED

MTG � MOUNTING

N � NEUTRAL

NC � NORMALLY CLOSED

NIC � NOT IN CONTRACT

NO � NORMALLY OPEN

No. � NUMBER

NTS � NOT TO SCALE

PA � PUBLIC ADDRESS

PNL � PANEL

POE � POWER OVER ETHERNET

PTZ � PAN/TILT/ZOOM

RM � ROOM

STP � SHIELDED TWISTED PAIR

XFRM � TRANSFORMER

TEL � TELECOMMUNICATIONS

TLR � TIME LAPSE RECORDER

TS � TAMPER SWITCH

TTB � TELECOMMUNICATIONS TERMINAL BOARD

TTC � TELECOMMUNICATIONS TERMINAL CABINET

TV � TELEVISION

TYP � TYPICAL

UON � UNLESS OTHERWISE NOTED

UPS � UNINTERRUPTIBLE POWER SUPPLY

UTP � UNSHIELDED TWISTED PAIR

V � VOLTS

VA � VOLT�AMPERES

VM � VOLTIMETER

VP � VAPER PROOF

W � WATTS

WP � WATERPROOF

WT � WATER TIGHT

F = FAIL SAFE

S = FAIL SECURE

SECURITY � DEVICE SYMBOL / TAG LEGEND

ACP

AFP

ACS

AN

AO

AP

CCTV

DE

GCR

EN

GT

GB

HE

DVR

ECB

ECP

DR

1 P

KP

K

LA

MON

MUX

NVR

WC

WS

SR

XLP

XCP

SBR

SI

VBS

MD

PB

1 P

MD

MA

AC

1 P

DC

1 R

EL

1 F

ES

1 F

ML

1 F

TH

RX

1 M

VI

1 S

IC

1 S

EE

1 F

DAP

XX

WALL MOUNT

INSIDE CORNER MOUNT

OUTSIDE CORNER MOUNT

CEILING MOUNT

SHEN MILSOM WILKE

San Francisco, CA 94105

Fax: 415�391�0171 Tel: 415�391�7610

33 New Montgomery Street

201 Mission Street, Suite 2400, San Francisco, California 94105 415.243.4170 on e� qu ar te r in ch o ne fo ot on e� ei gh th in ch o ne fo ot

Revisions

8 4

Date on e� ha lf in ch o ne fo ot th re e� ei gh th s in ch o ne fo ot th re e� qu ar te rs in ch o ne fo ot

Building Number:

Approved: Project Director

Drawing Title Project Title

Date

F

E

D on e an d on e� ha lf in ch es o ne fo ot on e in ch o ne fo ot th re e in ch es o ne fo ot

1 2 3 4 5 6 7 8 9

C

B

A

Location

Checked Drawn

Drawing No.

VA Project Number:

CONSULTANTS: ARCHITECT/ENGINEERS:

Baltimore ■ Boston ■ Buffalo ■ Calgary ■ Chicago Houston ■ Los Angeles ■ Mumbai ■ New York ■ Phoenix

St. Louis ■ San Francisco ■ Shanghai ■ Toronto Vancouver ■ Victoria ■ Washington DC

F

E

D

C

B

A

1 2 3 4 5 6 7 8 9 10

GENERAL NOTES

KEY NOTES

LEGEND

Veterans Affairs Palo Alto Heath Care System 3801 Miranda Ave,Palo Alto, CA 94304

640�385

Seals and Signatures

SC0000

SECURITY GENERAL NOTES,

ABBREVIATIONS, SYMBOLS, AND

DRAWING LIST

Approver

BB RMJUNE 14, 2013

VA SIMULATION CENTER

ISSUE FOR BID

SECURITY DRAWING LIST

SC0000 SECURITY GENERAL NOTES, ABBREVIATIONS, SYMBOLS, AND DRAWING LIST

SC0201 SECURITY LEVEL 1 FLOOR PLAN

SC0202 SECURITY LEVEL 2 AND ROOF PLAN

SC0300 SECURITY ENLARGED PLANS AND ELEVATIONS

SC0400 SECURITY RISER DIAGRAM

SC0500 SECURITY DETAILS

vhapalvigils Typewritten Text For reference only Drawing from previous project Security Cameras are not in Scope only installation of card readers, power, and communications to form a complete card reader system.

FCR1

FCR1

G

G1 G1

G1

G

G

G

FCR1 FCR1

FCR1

G1G

G

G

W

W

W

G1

G

G

G

G1

G

G1

G1

G1

J

LR

C

GROUND

E0201

1 2 3

A

B

C

D

E

F

G

2.61.7 4

D.1

LARGE SIMULATION

B152

STORAGE

B154

CONTROL

B155

PATIENT ROOM (SHELL)

B156

PATIENT ROOM

B157

CONTROL

B158

PATIENT ROOM

B159

DEBRIEFING ROOM-2

B160

DEBRIEFING ROOM-1

B151

ANTE ROOM

B153 ELECT

B165

MECHANICAL

B176

PREP/STORAGE

B172

DEBRIEFING ROOM-3

B174

STORAGE

B168

CLINIC ROOM,

B173

LEARNER

SEQUESTRATION

B170

TOILET, FEMALE

B175

AV RACK ROOM

B164

WET AND DRY UTILITY

B167

MEDICAL GAS STORAGE

B163

LOBBY

A100

RECEPTION

B171

HAC

B177

TOILET, MALE

B161

CORRIDOR

C-10

CORRDIOR

C-11

+72"

VP

TYP

B-1

RP-1DWH-1

P

P-2

+66"

5 5

11 11

1LNL2-15

1LNL2-17

232527

W

1LN2-

20,223535

353533

3937 41

6 OFFICE, SHARED

B166

DISHWASHER

20 22

A: 43 B: 45 C: 47

A: 49 B: 51 C: 53

A: 61 B: 63 C: 65

A: 55 B: 57 C: 59

28 30 30 32

32 32

A: 67 B: 69 C: 71

A: 73 B: 75 C: 77

A: 44 B: 46 C: 48

D: 50 E: 52 F: 54

A: 56 B: 58 C: 60

D: 62 E: 64 F: 66

74 76

78 78

E M

S 1LEL1-10

TV

+72"

TV

+72"

TV

+72"

TV

+72"

TV

+72"

+66"

+66"

1LNL2-12

1LEL1-7

AC-2

T T

T

T

FCU-1

T

70 6

COPIER

SMOKE

CONTROL

PANEL

1LEL1-8

1LEL1-12

DH

1LNL2-12

DH

1LNL2-12

DH

1LNL2-12

DH

+66"

+72"

1LEL1-9

1LEL1-9

1LNL2-15

1LNL2-17

1LNL2-17

1LNL2-17

DRYER

1LNH1

1PNH1

1T1

1LNL1

B

2.6

1LRC1

ELECT

B165

1LNL2

D

M DIGITAL METER

1LEH1

1LEL1

1ATS1

1PNL1

CCT A

CCT B

CCT C

CCT D

CCT E

CCT F

CCT A

CCT B

CCT C

201 Mission Street, Suite 2400, San Francisco, California 94105 415.243.4170 on e-qu ar te r in ch o ne fo ot on e-ei gh th in ch o ne fo ot

Revisions

8 4

Date on e-ha lf in ch o ne fo ot th re e-ei gh th s in ch o ne fo ot th re e-qu ar te rs in ch o ne fo ot

Building Number:

Approved: Project Director

Drawing Title Project Title

Date

F

E

D on e an d on e-ha lf in ch es o ne fo ot on e in ch o ne fo ot th re e in ch es o ne fo ot

1 2 3 4 5 6 7 8 9

C

B

A

Location

Checked Drawn

Drawing No.

VA Project Number:

CONSULTANTS: ARCHITECT/ENGINEERS:

Baltimore ■ Boston ■ Buffalo ■ Calgary ■ Chicago Houston ■ Los Angeles ■ Mumbai ■ New York ■ Phoenix

St. Louis ■ San Francisco ■ Shanghai ■ Toronto Vancouver ■ Victoria ■ Washington DC

F

E

D

C

B

A

1 2 3 4 5 6 7 8 9 10

GENERAL NOTES

KEY NOTES

PROJECT

NORTH

LEGEND

Veterans Affairs Palo Alto Heath Care System 3801 Miranda Ave,Palo Alto, CA 94304

640-385

Seals and Signatures

TRUE

NORTH

E0201

LEVEL 01 POWER PLAN

Approver

RJG JSSSEP 26, 2014

VA SIMULATION CENTER

ISSUE FOR CONSTRUCTION

1/8" = 1'-0"

LEVEL 01 PLAN

1/4" = 1'-0"

ENLARGED ELECTRICAL RM B165

1.

CONNECTIONS FOR GAS MANIFOLDS. COORDINATE WITH

EQUIPMENT MANUFACTURER.

2.

CONNECTION FOR GAS ALARM PANEL.

3.

PROVIDE J-BOX AND 3/4"C TO ACCESSIBLE CEILING

SPACE FOR DIRECTORY DISPLAY. CONFIRM EXACT

MOUNTING HEIGHT WITH EQUIPMENT SUPPLIER.

4.

COLUMN MOUNTED DEVICES. SEE 3/E0201 FOR TYPICAL

CIRCUIT DESIGNATIONS. CIRCUIT ASSIGNMENTS ARE

SHOWN ON FLOOR PLANS. (EXAMPLE- A:13 IS TOP/LEFT

(3) RECEPTACLES WIRED TO CIRCUIT13 ON PANEL 1LNL1)

SEE DETAIL 1/A0801 FOR MORE INFORMATION.

5.

CONNECTION TO EXTERIOR CCTV CAMERA.

COORDINATE EXACT LOCATION WITH SECURITY

VENDOR.

6.

CONFIRM EXACT LOCATION OF MECHO-SHADE IN THE

FIELD.

7.

WALL MOUNTED DEVICES. SEE 4/E0201 FOR TYPICAL

CIRCUIT DESIGNATIONS. CIRCUIT ASSIGNMENTS ARE

SHOWN ON FLOOR PLANS. (EXAMPLE- A:13 IS TOP (3)

RECEPTACLES WIRED TO CIRCUIT13 ON PANEL 1LNL1)

SEE DETAIL 5/A0801 FOR MORE INFORMATION.

8.

LOCATION OF SOUTH DOOR HARDWARE. CONTINUE

CIRCUIT TO NEW DOOR HARDWARE ON EXISTING DOOR

AS SHOWN BY KEYED NOTE #10 ON SHEET E0101.

9.

LOCATION OF NORTH DOOR HARDWARE. CONTINUE

CIRCUIT TO NEW DOOR HARDWARE ON EXISTING DOOR

AS SHOWN BY KEYED NOTE #11 ON SHEET E0101.

10.

COORDINATE EXACT LOCATION WITH TV MOUNTING

BRACKET.

1.

UNLESS NOTED OTHERWISE, WIRE ALL 208/120V DEVICES

TO PANELBOARD 1LNL1 LOCATED IN ELEC RM B165.

2.

UNLESS NOTED OTHERWISE, WIRE ALL 480/277V DEVICES

TO PANELBOARD 1LNH1 LOCATED IN ELEC RM B165.

1 2 1

BRANCH CIRCUIT NOTES

NTS

TYPICAL HEADWALL

ELEVATION- COLUMN

MOUNTED DEVICES

NTS

TYPICAL HEADWALL

ELEVATION- WALL

MOUNTED DEVICES

ADDENDUM 1 02/06/2014

jdavies Single Pole Switch jdavies Single Pole Switch jdavies Single Pole Switch jdavies Single Pole Switch jdavies Single Pole Switch jdavies Single Pole Switch nmcreynolds Line nmcreynolds Line nmcreynolds Line nmcreynolds Line nmcreynolds Line nmcreynolds Line nmcreynolds Line nmcreynolds Line nmcreynolds Line nmcreynolds Line nmcreynolds Line nmcreynolds Line nmcreynolds Line nmcreynolds Line nmcreynolds Line nmcreynolds Line nmcreynolds Line nmcreynolds Line nmcreynolds Line nmcreynolds Line nmcreynolds Line nmcreynolds Line akarastanov Callout

POWER

3/4" EMT

3#12THHN

akarastanov Callout Control Wire Installed on the J-Hooks 6' OC Typical All Switches akarastanov Callout 6' 1/2 Flex (With 2 Connectors ) Another box with cover vhapalvigils Callout Provide above ceiling 120 volt power for overhead coil door motor and switch for motor control operation.

vhapallappir Snapshot

QAUX QEYEQAUX QEYE

RQ60AUMH115 MOTOR CONTROLLERS IN

A CUSTOM PANEL

14/4 ELECTRICAL WIRE 120 VAC

NEUTRAL

HOT DIRECTIONAL

HOT DIRECTIONAL

GROUND

HDC 100S

HDC 200S

HDC 100S

HDC 200S

HDC 100S

HDC 200S

Motor 1Motor 2Motor 3Motor 4

M o to r C o n tr o lle rs

AC

Power

HDC 100S

HDC 200S

HDC 100S

HDC 200S

QAUX QEYE

HDC 100S

HDC 200S

QAUX QEYE

R J1

R J1

R J1

R J1

R J1

R J1

AUX EYE AUX EYE AUX EYE AUX EYE

RQ60AUMH115 RQ60AUMH115 RQ60AUMH115

Optional Quick Disconnect Plug

Available

RQ60AUMH115

M o to r C o n tr o lle rs

M o to r C o n tr o lle rs

M o to r C o n tr o lle rs

RQ60 direct input for dry contact control

RJ12

R J1

R J1

Neutral

HOT

Ground

K24ST

Keypad

OVERLAY0002

OVERLAY0012

OVERLAY0073

OVERLAY0071

OVERLAY0001

OVERLAY0074

OVERLAY0072

OVERLAY0070

K12ST, K24ST

Keypad (Wall Switch) for operating RPs or RQs on either channels 1 through 12 and ALL, or channels 1 through 24 and ALL. Twenty-eight buttons with “Shift” function (24 channel only) and LED feedback. Buttons can be “Selectable” and ”Trainable” to any of the RP commands. Includes built-in IR Eye. Features screw-less cover plate.

Case color: White.

Keypad and overlay sold together.

ESI PART #s:

K12ST (includes OVERLAY0002)

K24ST (includes OVERLAY0001)

K1ST, K2ST, K3ST, K4ST, K5ST, K6ST

Keypad (Wall Switch) for operating RPs or RQs on channels 1 through 6. Buttons can be “Selectable” and “Trainable” to any of the RP commands. Includes built-in IR Eye. No programming or ALL functions. Up to twelve buttons with LED feedback. Features screw-less cover plate.

Case color: White.

Keypad and overlay sold together.

For example, the K1ST (one channel) will be sold with OVERLAY0070, the overlay for one channel.

ESI PART #s:

K1ST (includes OVERLAY0070)

K2ST (includes OVERLAY0071)

K3ST (includes OVERLAY0072)

K4ST (includes OVERLAY0073)

K5ST (includes OVERLAY0074)

K6ST (includes OVERLAY0012)

Input Devices Keypads | RP Bus

OVERLAY0002

OVERLAY0012

OVERLAY0073

OVERLAY0071

OVERLAY0001

OVERLAY0074

OVERLAY0072

OVERLAY0070

K12ST RF 433, K24ST RF 433

Keypad (Wall Switch) for operating RPs or RQs on either channels 1 through 12 and ALL, or channels 1 through 24 and ALL. Twenty-eight buttons with “Shift” function (24 channel only) and LED feedback. Buttons can be “Selectable” and ”Trainable” to any of the RP commands. Battery operated for wireless radio installation. Includes RFTM and screw-less cover plate.

NOTE: transmits only to the RR433.

Case color: White.

Keypad and overlay sold together.

ESI PART #s:

K12ST RF 433 (includes OVERLAY0002)

K24ST RF 433 (includes OVERLAY0001)

K1ST RF 433, K2ST RF 433, K3ST RF 433,

K4ST RF 433, K5ST RF 433, K6ST RF 433

Keypad (Wall Switch) for operating RPs or RQs on channels 1 through 6. Up to twelve buttons with LED feedback.

Buttons can be “Selectable” and “Trainable” to any of the RP commands.

Battery operated for wireless radio installation. No programming or ALL functions. Includes RFTM and screw-less cover plate.

NOTE: transmits only to the RR433.

Case color: White.

Keypad and overlay sold together.

For example, the K1ST RF 433 (one channel) will be sold with OVERLAY0070, the overlay for one channel.

ESI PART #s:

K1ST RF 433 (includes OVERLAY0070)

K2ST RF 433 (includes OVERLAY0071)

K3ST RF 433 (includes OVERLAY0072)

K4ST RF 433 (includes OVERLAY0073)

K5ST RF 433 (includes OVERLAY0074)

K6ST RF 433 (includes OVERLAY0012)

Input Devices Keypads | Radio Frequency (RF) vhapallappir Snapshot vhapallappir Snapshot vhapallappir Snapshot vhapallappir Snapshot vhapallappir Snapshot vhapallappir Snapshot vhapallappir Snapshot vhapallappir Snapshot vhapallappir Snapshot vhapallappir Snapshot vhapallappir Snapshot vhapallappir Snapshot vhapallappir Snapshot vhapallappir Snapshot vhapallappir Snapshot vhapallappir Snapshot vhapallappir Snapshot vhapallappir Snapshot vhapallappir Snapshot vhapallappir Snapshot vhapallappir Snapshot vhapallappir Snapshot vhapallappir Snapshot vhapallappir Snapshot vhapallappir Snapshot vhapallappir Snapshot vhapallappir Snapshot vhapallappir Snapshot vhapalhuanggc

New Automatic door opener vhapalhuanggc Rectangle vhapalhuanggc Callout Power Source vhapallappir Snapshot vhapallappir Snapshot vhapallappir Snapshot vhapallappir Snapshot vhapallappir Snapshot vhapallappir Snapshot vhapallappir Snapshot vhapallappir Snapshot vhapallappir Snapshot

UP

1 2 3

A

B

C

D

E

F

G

(E) EDUCATION CENTER(N) SIMULATION CENTER

(E) EDUCATION CENTER(N) SIMULATION CENTER

LARGE SIMULATION

B152

STORAGE

B154

CONTROL

B155

PATIENT ROOM

(SHELL)

B156

PATIENT ROOM

B157

CONTROL

B158

PATIENT ROOM

B159

DEBRIEFING

ROOM�2

B160

DEBRIEFING

ROOM�1

B151

ANTE ROOM

B153

ELECT

B165

MECHANICAL

B176

PREP/STORAGE

B172

DEBRIEFING

ROOM�3

B174

STORAGE

B168

CLINIC ROOM,

B173

LEARNER

SEQUESTRATION

B170

TOILET, FEMALE

B175

AV RACK ROOM

B164

WET AND DRY

UTILITY

B167

MEDICAL GAS

STORAGE

B163

LOBBY

A100

2.6

RECEPTION

B171

HAC

B177

TOILET, MALE

B161

CORRIDOR

C�10

CORRDIOR

C�11

1.7

OFFICE, SHARED

B166

D.1

B153

B152A

B155A

B158

B156

B152B

B157

B159

B167

B168B

B173

B176

B174

B177

B170B

B172

B175

B170A

B152C

B B

B171A

B164

B168A

C�10B

B161

C�10A

C�11A

B166

B163

B165

B160

C�11B

A100A

B151

FLOOR LINE

ABOVE

FLOOR LINE

ABOVE

B B

A100B

ALIGN

C D E

B.3

B

C.7

6.8

4.8

A.9

1.5

2.5

MULTI�PURPOSE

CLASS ROOM

ELEVATOR

MACHINE RM

ELEC

IRMS

AUDITORIUM

STAIR

S�1

WOMENS

MENS

ELEVATOR

CORRIDOR

C�4

HALLWAY

C�3

HAC / SPRINKLER

PREFUNCTION

C�2

STAIR

S�2

HALLWAY

C�5

STORAGE

STORAGE

STORAGE

HAC/STORAGE

AUDITORIUM

DC

1 R

DC

2 R

AC

1 P

AO

PTZ

AC

1 P

DC

1 R

EL

1 F

DC

1 R

EL

1 F

AC

1 P

DC

1 R

PTZ

DC

2 R

AO

EL

1 F

AC

1 P

SC0300

SC0500

SC0500

SC0500

SC0500

SC0500

SC0500

SC0500

SR

EL

1 F

AC

1 P

SC0500

EL

1 F

1. ALL EQUIPMENT TO BE PROVIDED IN

THE FUTURE. ONLY PROVIDE

INFRASTRUCTURE (POWER, CONDUIT,

BACKBOXES, ETC.) AS INDICATED ON

SHEET SC0500.

SHEN MILSOM WILKE

San Francisco, CA 94105

Fax: 415�391�0171 Tel: 415�391�7610

33 New Montgomery Street

201 Mission Street, Suite 2400, San Francisco, California 94105 415.243.4170 on e� qu ar te r in ch o ne fo ot on e� ei gh th in ch o ne fo ot

Revisions

8 4

Date on e� ha lf in ch o ne fo ot th re e� ei gh th s in ch o ne fo ot th re e� qu ar te rs in ch o ne fo ot

Building Number:

Approved: Project Director

Drawing Title Project Title

Date

F

E

D on e an d on e� ha lf in ch es o ne fo ot on e in ch o ne fo ot th re e in ch es o ne fo ot

1 2 3 4 5 6 7 8 9

C

B

A

Location

Checked Drawn

Drawing No.

VA Project Number:

CONSULTANTS: ARCHITECT/ENGINEERS:

Baltimore ■ Boston ■ Buffalo ■ Calgary ■ Chicago Houston ■ Los Angeles ■ Mumbai ■ New York ■ Phoenix

St. Louis ■ San Francisco ■ Shanghai ■ Toronto Vancouver ■ Victoria ■ Washington DC

F

E

D

C

B

A

1 2 3 4 5 6 7 8 9 10

GENERAL NOTES

KEY NOTES

PROJECT

NORTH

LEGEND

Veterans Affairs Palo Alto Heath Care System 3801 Miranda Ave,Palo Alto, CA 94304

640�385

Seals and Signatures

TRUE

NORTH

SC0201

SECURITY LEVEL 1 FLOOR PLAN

Approver

BB RMJUNE 14, 2013

VA SIMULATION CENTER

ISSUE FOR BID

1/8" = 1'�0"

SECURITY LEVEL 1 FLOOR PLAN

vhapalvigils Typewritten Text Security Cameras are not in Scope vhapalvigils Typewritten Text For reference only Drawing from previous project Security Cameras are not in Scope only installation of card readers, power, and communications to form a complete card reader system.

vhapalvigils Callout Provide Card Reader vhapalvigils Callout Provide Card Reader vhapalvigils Callout Provide Card Reader vhapalvigils Callout Provide Card Reader vhapalvigils Callout Provide Card Reader vhapalvigils

Provide Card Reader

FLOOR SLAB

FLOOR SLAB

WIRE THROUGH

(TYPICAL)

NETWORK

CONNECTION

BY TELECOM

CONTRACTOR

3/4" FIRE RATED

PLYWOOD

BACKBOARD

NOTE:

4'X8' WALL FIELD SECTION RESERVED FOR FUTURE SECURITY EQUIPMENT

LOCATED WITHIN EXISTING IRMS (120) ROOM OF THE EDUCATION CENTER.

ELECTRICAL CONTRACTOR TO

PROVIDE A HARD WIRED

CONNECTION TO A 120VAC 20A

EMERGENCY CIRCUIT DEDICATED TO

SECURITY IN EACH RISER LOCATION

WITHIN A 4"X4" BOX SURFACE

MOUNTED 18" A.F.F. WITH WIRE ENDS

TERMINATED AND INSULATED WITH

WIRE NUTS

D

C.7

IRMS

SECURITY WALL FIELD

SEE DETAIL 2

SHEN MILSOM WILKE

San Francisco, CA 94105

Fax: 415339130171 Tel: 415339137610

33 New Montgomery Street

201 Mission Street, Suite 2400, San Francisco, California 94105 415.243.4170 on e� qu ar te r in ch o ne fo ot on e� ei gh th in ch o ne fo ot

Revisions

8 4

Date on e� ha lf in ch o ne fo ot th re e� ei gh th s in ch o ne fo ot th re e� qu ar te rs in ch o ne fo ot

Building Number:

Approved: Project Director

Drawing Title Project Title

Date

F

E

D on e an d on e� ha lf in ch es o ne fo ot on e in ch o ne fo ot th re e in ch es o ne fo ot

1 2 3 4 5 6 7 8 9

C

B

A

Location

Checked Drawn

Drawing No.

VA Project Number:

CONSULTANTS: ARCHITECT/ENGINEERS:

Baltimore ■ Boston ■ Buffalo ■ Calgary ■ Chicago Houston ■ Los Angeles ■ Mumbai ■ New York ■ Phoenix

St. Louis ■ San Francisco ■ Shanghai ■ Toronto Vancouver ■ Victoria ■ Washington DC

F

E

D

C

B

A

1 2 3 4 5 6 7 8 9 10

GENERAL NOTES

KEY NOTES

LEGEND

Veterans Affairs Palo Alto Heath Care System 3801 Miranda Ave,Palo Alto, CA 94304

6403385

Seals and Signatures

SC0300

SECURITY ENLARGED PLANS AND

ELEVATIONS

Approver

BB RMJUNE 14, 2013

VA SIMULATION CENTER

ISSUE FOR BID 3/4" = 1'30"

SECURITY EQUIPMENT ELEVATION (TYPICAL)

1/2" = 1'30"

IRMS 120 FLOOR PLAN LAYOUT

vhapalvigils Typewritten Text For reference only Drawing from previous project Security Cameras are not in Scope only installation of card readers, power, and communications to form a complete card reader system.

J

FIX

J

TYPICAL

OF 1

TO SECURITY RISER LOCATION

LOCATED IN EXISTING IRMS (120) ROOM

OF THE EDUCATION CENTER.

LEVEL 02

LEVEL 01

J

PTZ

J

TYPICAL

OF 2

J

F

TYPICAL

OF 1

DC

1 R

J

G,F

TYPICAL

OF 2

DC

2 R

AC

1 P

FD

EL

1 F

TH

J

G,F

TYPICAL

OF 3

DC

1 R

AC

1 P

FD

EL

1 F

TH

TO SECURITY RISER LOCATION

LOCATED IN EXISTING IRMS (120) ROOM

OF THE EDUCATION CENTER.

1. ALL EQUIPMENT TO BE PROVIDED

IN THE FUTURE. ONLY PROVIDE

INFRASTRUCTURE (POWER, CONDUIT,

BACKBOXES, ETC.) AS INDICATED ON

SHEET SC0500.

SECURITY CABLE LEGEND

WIRE TAG DEVICE/SYSTEM CONNECTIONS GUAGE (AWG) NO. OF PAIRS SHIELDED CABLE TYPE MAX. NOTES:

A CCTV VIDEO (COAXIAL) 18 � RG/6U SOLID 1200' OR APPROVED EQUAL

B CCTV VIDEO (COAXIAL) 20 � RG/59U SOLID 850' OR APPROVED EQUAL

C CCTV VIDEO (COAXIAL) 22 � RG/59U STRANDED 850' OR APPROVED EQUAL

D DATA (CARD READER) 24 3 YES 500' OR APPROVED EQUAL

E CONTROL, SWITCHING 22/18 3 COND. NO OR APPROVED EQUAL

F 22 4 COND. OR APPROVED EQUAL

G POWER (24V AC/DC) 18 1 OR APPROVED EQUAL

H POWER/CONTROL 18 2 OR APPROVED EQUAL

J COMMUNICATIONS (DATA) 24 4 UTP/CAT6 SOLID 295' OR APPROVED EQUAL

K 24 2 YES 4000' OR APPROVED EQUAL

L 22 2 YES SOLID 50' OR APPROVED EQUAL

M 20/18 � RG/59U SOLID 1200' OR APPROVED EQUAL

CONTROL, SWITCHING

COMMUNICATIONS (RS�485)

COMMUNICATIONS (RS�232)

VIDEO & POWER (SIAMESE)

NO

NO

NO

STRANDED

STRANDED

STRANDED

STRANDED

STRANDED

STRANDED

500'

500'

500'

500'

SHEN MILSOM WILKE

San Francisco, CA 94105

Fax: 415�391�0171 Tel: 415�391�7610

33 New Montgomery Street

201 Mission Street, Suite 2400, San Francisco, California 94105 415.243.4170 on e� qu ar te r in ch o ne fo ot on e� ei gh th in ch o ne fo ot

Revisions

8 4

Date on e� ha lf in ch o ne fo ot th re e� ei gh th s in ch o ne fo ot th re e� qu ar te rs in ch o ne fo ot

Building Number:

Approved: Project Director

Drawing Title Project Title

Date

F

E

D on e an d on e� ha lf in ch es o ne fo ot on e in ch o ne fo ot th re e in ch es o ne fo ot

1 2 3 4 5 6 7 8 9

C

B

A

Location

Checked Drawn

Drawing No.

VA Project Number:

CONSULTANTS: ARCHITECT/ENGINEERS:

Baltimore ■ Boston ■ Buffalo ■ Calgary ■ Chicago Houston ■ Los Angeles ■ Mumbai ■ New York ■ Phoenix

St. Louis ■ San Francisco ■ Shanghai ■ Toronto Vancouver ■ Victoria ■ Washington DC

F

E

D

C

B

A

1 2 3 4 5 6 7 8 9 10

GENERAL NOTES

KEY NOTES

LEGEND

Veterans Affairs Palo Alto Heath Care System 3801 Miranda Ave,Palo Alto, CA 94304

640�385

Seals and Signatures

SC0400

SECURITY RISER DIAGRAM

Approver

BB RMJUNE 14, 2013

VA SIMULATION CENTER

ISSUE FOR BID

NTS

SECURITY RISER DIAGRAM

vhapalvigils Typewritten Text Security Cameras are not in Scope

FINISHED FLOOR

FINISHED CEILING

CEILING SLAB

JB

DETAIL NOTES:

1. DOOR POSITION SWITCH

2. ELECTRICAL CONTRACTOR TO PROVIDE 4" X 4" X 2�1/8"DEEP JUNCTION BOX ABOVE DOOR, ABOVE

ACCESSIBLE CEILING.

3. ELECTRICAL CONTRACTOR TO PROVIDE 3/4" CONDUIT TO NEAREST SECURITY RISER LOCATION OR CABLE TRAY, WHICHEVER IS CLOSER. REFER TO TC SERIES DRAWINGS FOR ADDITIONAL INFORMATION

ON CABLE TRAY.

FINISHED FLOOR

CEILING SLAB

FINISHED CEILING

JB

DETAIL NOTES:

1. DOOR POSITION SWITCH

2. ELECTRIFIED MORTISE LOCKING DEVICE WITH INTEGRAL

REQUEST TO EXIT DEVICE, BY DOOR HARDWARE CONTRACTOR

3. CARD READER. ELECTRICAL CONTRACTOR TO PROVIDE 4" X

4" X 2�1/8" DEEP JUNCTION BOX.

4. ELECTRIC HINGE BY DOOR HARDWARE CONTRACTOR.

5. ELECTRICAL CONTRACTOR TO PROVIDE 4" X 4" X 2�1/8" DEEP

JUNCTION BOX ABOVE DOOR, ABOVE ACCESSIBLE CEILING.

# 6. ELECTRICAL CONTRACTOR TO STUB 3/4" CONDUIT OR

GREENFIELD DOWN DOOR FRAME ON THE HINGE SIDE OF THE

DOOR BACK BOX, TO JUNCTION BOX LOCATED ABOVE

ACCESSIBLE CEILING

7. ELECTRICAL CONTRACTOR TO STUB 3/4" CONDUIT WITH

DRAG LINE.

8. ELECTRICAL CONTRACTOR TO PROVIDE 3/4" CONDUIT TO

NEAREST SECURITY RISER LOCATION OR CABLE TRAY,

WHICHEVER IS CLOSER. REFER TO TC SERIES DRAWINGS FOR

ADDITIONAL INFORMATION ON CABLE TRAY.

FINISHED FLOOR

FINISHED CEILING

CEILING SLAB

JB

DETAIL NOTES:

1. DOOR POSITION SWITCH

2. ELECTRIFIED MORTISE LOCKING DEVICE WITH INTEGRAL

REQUEST TO EXIT DEVICE, BY DOOR HARDWARE CONTRACTOR

3. CARD READER. ELECTRICAL CONTRACTOR TO PROVIDE 4" X

4" X 2�1/8" DEEP JUNCTION BOX.

4. ELECTRIC HINGE BY DOOR HARDWARE CONTRACTOR.

5. ELECTRICAL CONTRACTOR TO PROVIDE 6" X 6" X 4" DEEP

JUNCTION BOX ABOVE DOOR, ABOVE ACCESSIBLE CEILING.

# 6. ELECTRICAL CONTRACTOR TO STUB 3/4" CONDUIT OR

GREENFIELD DOWN DOOR FRAME ON THE HINGE SIDE OF THE

DOOR BACK BOX, TO JUNCTION BOX LOCATED ABOVE

ACCESSIBLE CEILING

7. ELECTRICAL CONTRACTOR TO STUB 3/4" CONDUIT WITH

DRAG LINE.

8. ELECTRICAL CONTRACTOR TO PROVIDE 3/4" CONDUIT TO

NEAREST SECURITY RISER LOCATION OR CABLE TRAY,

WHICHEVER IS CLOSER. REFER TO TC SERIES DRAWINGS FOR

ADDITIONAL INFORMATION ON CABLE TRAY.

DETAIL NOTES:

1. 6"x 6"x 4" DEEP BOX MOUNTED FLUSH IN WALL BY ELECTRICAL CONTRACTOR

2. CONDUIT AND JUNCTION BOX WITH IP DATA JACK PROVIDED WITHIN TELECOMMUNICATIONS

PACKAGE. REFER TO TELECOMMUNICATION SERIES DRAWINGS FOR ADDITIONAL INFORMATION

3. CCTV CAMERA IN ENVIRONMENTAL HOUSING MOUNTED 20' MINIMUM (EXTERIORS)

4. WALL

5. CORNER MOUNT FOR CAMERA DOME

DETAIL NOTES:

1. FINISHED CEILING PER ARCHITECTURAL DRAWINGS

2. CCTV CAMERA DOME

3. NEOPRANE GASKET WEATHER SEAL ALL AROUND

4. STRUCTURAL SUPPORT BY BUILDING PER NEC

5. 2�1/2" DEEP 2 GANG BOX BY ELECTRICAL CONTRACTOR

6. CONDUIT AND JUNCTION BOX WITH IP DATA JACK PROVIDED WITHIN TELECOMMUNICATIONS PACKAGE.

REFER TO TELECOMMUNICATIONS SERIES DRAWINGS FOR ADDITIONAL INFORMATION.

7. IP JUMPER CABLE BY SECURITY CONTRACTOR

GENERAL NOTES:

1. REFER TO FLOOR PLANS FOR EXACT MOUNTING HEIGHTS

1. ALL EQUIPMENT TO BE PROVIDED

IN THE FUTURE. ONLY PROVIDE

INFRASTRUCTURE (POWER, CONDUIT,

BACKBOXES, ETC.) AS INDICATED.

SHEN MILSOM WILKE

San Francisco, CA 94105

Fax: 415�391�0171 Tel: 415�391�7610

33 New Montgomery Street

201 Mission Street, Suite 2400, San Francisco, California 94105 415.243.4170 on e� qu ar te r in ch o ne fo ot on e� ei gh th in ch o ne fo ot

Revisions

8 4

Date on e� ha lf in ch o ne fo ot th re e� ei gh th s in ch o ne fo ot th re e� qu ar te rs in ch o ne fo ot

Building Number:

Approved: Project Director

Drawing Title Project Title

Date

F

E

D on e an d on e� ha lf in ch es o ne fo ot on e in ch o ne fo ot th re e in ch es o ne fo ot

1 2 3 4 5 6 7 8 9

C

B

A

Location

Checked Drawn

Drawing No.

VA Project Number:

CONSULTANTS: ARCHITECT/ENGINEERS:

Baltimore ■ Boston ■ Buffalo ■ Calgary ■ Chicago Houston ■ Los Angeles ■ Mumbai ■ New York ■ Phoenix

St. Louis ■ San Francisco ■ Shanghai ■ Toronto Vancouver ■ Victoria ■ Washington DC

F

E

D

C

B

A

1 2 3 4 5 6 7 8 9 10

GENERAL NOTES

KEY NOTES

LEGEND

Veterans Affairs Palo Alto Heath Care System 3801 Miranda Ave,Palo Alto, CA 94304

640�385

Seals and Signatures

SC0500

SECURITY DETAILS

Approver

BB RMJUNE 14, 2013

VA SIMULATION CENTER

ISSUE FOR BID

NTS

DOOR CONTACT SINGLE DOOR

NTS

MORTISE LOCKING DEVICE, CARD READER CONFIGURATION

NTS

MORTISE LOCKING DEVICE, CARD READER CONFIGURATION

NTS

CCTV CAMERA � CORNER MOUNT

NTS

INTERIOR CEILING MOUNTED CCTV MINI�DOME IP CAMERA

vhapalvigils Typewritten Text Conduits shown have been installed by building contractor Card readers, power conductors, communication conductors, and pathway to IRMS room 120 are part of scope.

Contractor shall provide for (5) of each type of building acoustical ceiling tiles to be replaced as damaged by project work.