SALIENT CHARACTERISTICS/PRICING SCHEDULE
“Brand Name or Equal”
EQUIPMENT REQUIREMENT: Manufacture: Odulair Model: HD2-NHD1 - USP 800 Mobile Trailer Facility.
Company is to design and build a 53' semi-trailer with one large ante room, one hazardous buffer room and one non-hazardous buffer room that meets USP 800 and USP 797 code compliance.
Drawings will be provided with the below salient characteristics. The Drawings/Semi-trailer will comply with the features listed below and the attached drawing:
Salient Characteristics USP 800 Hazardous Drug & USP 797 Non-Hazardous Drug Pharmaceutical Compounding Pharmacy Trailer
ROOMS & AREAS
• Ante Room ISO 7
• Sterile Hazardous Drug Buffer Room ISO 7
• Sterile Non-Hazardous Drug Buffer Room ISO 7
• Sterile Hazardous Drug Storage Area
• Self-Supporting Modular Design inclusive of walls, roof / ceiling, flooring, lighting, electrical & filtering equipment
• Modular clean room must fit within our trailer or within your designated space
• Modular Clean Room seismic integrity provisions where necessary
• Finishes - Non-porous and cleanable surfaces, ceilings, walls, and floors subject to wet cleaning
ANTE ROOM
• 2 Scrub sinks with eye wash station positioned at least 3’ from the Sterile HD Buffer Room door
• Clean Personal Protective Equipment (PPE) Storage Bin
• Soiled PPE Waste Bin
• Staff Changing Bench
• Environmental Services Closet
STERILE HAZARDOUS DRUG BUFFER ROOM Equipment
• 2 ISO 5 Class II Type B2 Biological Safety Cabinets (BSC) with 100% Outside Air Supply and Exhaust - 3ft each
• Interlocking HEPA filtered Pass-Thru Chamber from Ante Room
• Stainless Steel Workstation
• RFID Refrigerator for inventory control
• Soiled PPE Waste Bin
• Storage Cabinet for sterile hazardous drugs
STERILE NON-HAZARDOUS DRUG BUFFER ROOM Equipment
Attachment 1
• ISO 5 Horizontal Laminar Airflow Workbench ( LAFW) - 4ft
• Interlocking HEPA Filtered Pass-Thru Chamber from Ante Room
• Stainless Steel Workstation
• USP 797 Compliant Refrigerator
• Soiled PPE Waste Bin
• Non-Hazardous Drug Storage Cabinet
MECHANICAL ROOM
• Back-up Generator With Automatic Transfer Switch
• Water Storage Tanks (Fresh & Gray)
• Data Connection Package - Interior Video Intercom System
UTILITY REQUIREMENTS
• Electrical: 208V 3-Phase 200 Amps
• Water: 1" Potable Water Line
• Sewer: 4" Standard Sewer Line
WHEELCHAIR RAMP
• ADA Compliant
• Aluminum ramp with guardrails, landing, and stairs
• Width: 4'
• Installation on site
ENVIRONMENTAL CONTROLS
• All Facility & Engineering Controls Compliant with new USP 800 and USP 797
• Physically separated Ante Room and Sterile Hazardous Drug Buffer Room and Sterile Non Hazardous Drug Buffer
Room
• C-PEC Containment Primary Environmental Control: (BSC or LAFW) LControls) o ISO 5 Biological Safety Cabinet (BSC) located in the Sterile HD Buffer Room o ISO 5 LAFW located in Sterile Nonhazardous Buffer Room
• C-SEC Containment Secondary Environmental Controls (Room Controls) o ISO 7 Ante Room Environmental Controls:
• Positive pressure
• Minimum of 30 Air Exchanges Per Hour (ACPH) compliant with USP 800
• High Efficiency Particulate Air (HEPA) filtered supply air
• 24/7 Real-time Environmental Room Monitor providing:
❖ Temperature ❖ Humidity ❖ Differential pressure ❖ Airborne particle count o ISO 7 Sterile HD Buffer Room Environmental Controls:
• Negative pressure between 0.01” to 0.03” WC
• Minimum of 30 Air Exchanges Per Hour (ACPH) compliant with USP 800
• 100% Outside Supply Air (into room)
• High Efficiency Particulate Air (HEPA) filtered supply air
• Externally Vented 100% of Air Exhausted Directly Outside
• Zero recirculation of HD Buffer Room air
• 24/7 Real-time Environmental Room Monitor providing:
❖ Temperature ❖ Humidity ❖ Differential pressure ❖ Airborne particle count
• 24/7 Real-time Monitoring of RFID Refrigerator interior temperature to ensure drug safety o ISO 7 Sterile Non-HD Buffer Room Environmental Controls:
• Positive pressure
• Minimum of 30 Air Exchanges Per Hour (ACPH) compliant with USP 800
• High Efficiency Particulate Air (HEPA) filtered supply air
• 24/7 Real-time Environmental Room Monitor providing:
❖ Temperature ❖ Humidity ❖ Differential pressure ❖ Airborne particle count ❖ 24/7 Real-time Monitoring of RFID Refrigerator interior temperature to ensure drug safety
COMMISSIONING & CERTIFICATION
• Delivery
• Set-up
• On-site Test & Balance Certification
• Certification Supervision
• On-site Training
| SALIENT CHARACTERISTICS/PRICING SCHEDULE |
| ROOMS & AREAS |
| ANTE ROOM |
| STERILE HAZARDOUS DRUG BUFFER ROOM Equipment |
| STERILE NON-HAZARDOUS DRUG BUFFER ROOM Equipment |
| MECHANICAL ROOM |
| UTILITY REQUIREMENTS |
| WHEELCHAIR RAMP |
| ENVIRONMENTAL CONTROLS |
| COMMISSIONING & CERTIFICATION |