About this file

36C26118B0301 A0005 SECTION 27 51 19 RFI 008.pdf

View the file

Other files

File Type Posted
RFI_016_Attachment_-_Updated_Equipment_List.pdf PDF
RFI_Responses_-_Revised_Version_12-21-18-R2.pdf PDF
36C26118B0301_A0005.docx DOCX document
RFI_037_Attachment_-_2_Drawings.pdf PDF
General_Decision_Number_CA29_12072018.pdf PDF
PRRC_ADDENDUM_2_-_12-19-2018.pdf PDF
36C26118B0301_A0004.docx DOCX document
36C26118B0301-A0003005.pdf PDF
36C26118B0301-A0003001.pdf PDF
36C26118B0301-A0003007.pdf PDF
36C26118B0301-A0003000.docx DOCX document
36C26118B0301-A0003006.pdf PDF
36C26118B0301-A0003003.pdf PDF
36C26118B0301-A0003004.pdf PDF
36C26118B0301-A0003002.pdf PDF
36C26118B0301-A0002001.pdf PDF
36C26118B0301-A0002004.pdf PDF
36C26118B0301-A0002000.docx DOCX document
36C26118B0301-A0002003.pdf PDF
36C26118B0301-A0002002.pdf PDF
36C26118B0301-A0002005.pdf PDF
36C26118B0301-A0001001.pdf PDF
36C26118B0301-A0001000.docx DOCX document
36C26118B0301-034.docx DOCX document
36C26118B0301-047.pdf PDF
36C26118B0301-046.pdf PDF
36C26118B0301-041.pdf PDF
36C26118B0301-045.pdf PDF
36C26118B0301-038.pdf PDF
36C26118B0301-050.pdf PDF
36C26118B0301-043.pdf PDF
36C26118B0301-035.docx DOCX document
36C26118B0301-037.pdf PDF
36C26118B0301-042.pdf PDF
36C26118B0301-049.pdf PDF
36C26118B0301-048.pdf PDF
36C26118B0301-039.pdf PDF
36C26118B0301-044.pdf PDF
36C26118B0301-051.pdf PDF
36C26118B0301-036.docx DOCX document
36C26118B0301-040.pdf PDF
36C26118B0301-033.docx DOCX document
36C26118B0301-004.docx DOCX document
36C26118B0301-003.docx DOCX document
Show all 44

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

CONSTRUCT PSYCHOSOCIAL REHABILITATION AND RECOVERY CENTER 612-503

MARTINEZ, CA ADDENDUM #1

Advance Design Consultants, Inc. 27 51 19 - 1 04/06/2016

SECTION 27 51 19

NETWORKED SOUND-MASKING EQUIPMENT

PART 1 - GENERAL

1.1 RELATED DOCUMENTS

A. Section 01 00 00 GENERAL REQUIREMENTS B. Section 27 05 11 REQUIREMENT FOR COMUINICATION INSTALLATION.

C. Section 27 08 00 COMMISSIONING OF COMMUNICATION SYSTEMS.

1.2 SUMMARY

A. This section includes Digital Signal Processors, electronic noise generators, amplifiers, wiring, loudspeakers, and controls and components to generate, amplify, distribute and reproduce digitally synthesized and stabilized background sound masking to improve speech privacy in zones of coverage. Components contained herein this paragraph may be collectively integrated in a printed circuit board, central control units, music paging interfaces or as part of a speaker unit.

1.3 DEFINITIONS AND REFERENCES

A. Test and Calibration Conditions: Spaces completely furnished but unoccupied, lights and HVAC systems on, HVAC system testing and balancing completed, ceiling components in place. Additional testing to be provided after space is occupied to adjust for variations in use.

B. Covered spaces: Spaces above which masking speakers are installed.

C. Pink Noise: Random noise signal with equal energy in each octave.

D. Sound Masking: Sound that reduces the intelligibility of intruding speech and the distraction from activity noise. Sound that when measured falls inside the “preferred curve”. The masking sound spectrum slopes downward with an increasing frequency. The rate of this slope of sound is 5 dB per octave, having a steeper roll-off above 2 KHz. The low frequency response is determined by the low frequency capabilities of the masking system loudspeakers.

1.4 AMERICAN NATIONAL STANDARDS INSTITUTE (ANSI):

A. ANSI S1.4 American National Standard Specification for Sound Level Meters B. ANSI S1.6 American National Standard Specification for Preferred Frequencies and

Band Numbers

Advance Design Consultants, Inc. 27 51 19 - 2 04/06/2016

C. for Acoustical Measurements D. ANSI S1.11 American National Standard Specification for Octave-Band and

Fractional-Octave-Band Analog and Digital Filters

1.5 AMERICAN SOCIETY FOR TESTING AND MATERIALS (ASTM):

A. ASTM E 1130-02 Standard Test Method for Objective Measurement of Speech Privacy in Open Offices Using Articulation Index.

B. ASTM E1573-02 Standard Test Method for Evaluating Masking Sound in Open Offices Using A- Weighted and One-Third Octave Band Sound Pressure Levels.

C. ASTM E 1374-93 Standard Guide for Open Office Acoustics and Applicable ASTM Standards.

D. ASTM E1041-85 – Standard Guide for Measurement of Masking Sound in Open Offices.

1.6 SYSTEM PERFORMANCE

A. The Sound Masking system must use one control unit for the entire system.

Multiple control units are not acceptable.

B. The Sound Masking system must use a unique integrated sound masking, music and paging system that uses the power of network technology, web appliances, internet access, infrared remote controls and digital signal processors (DSP’s).

C. The sound masking system must be capable of separately and independently configuring zones for sound masking, paging and music via the network empowered through its central control.

D. The sound masking system must produce 20Hz through 20,000Hz from its source.

E. The masking must be random and provide a minimum pattern of no LESS than 25 hours.

F. The sound masking devices must provide both a 1/3 octave band equalizer for a minimum of 30 bands and a parametric equalizer to adjust the sound masking.

G. The paging devices must have a minimum of a 1/1 octave band equalizer to shape sound.

H. The System must provide global muting function through dry contact closure for fire alarms.

I. The System must provide automatic Adaptive Equalization to ensure a flat response for the entire building for paging.

J. The System must provide zone overlap where each speaker channel has a minimum of 10 programmable zones for masking, paging and music separately.

K. The System must meet ANSI 709.1 / ISO / IEC standards for open platform.

Advance Design Consultants, Inc. 27 51 19 - 3 04/06/2016

L. The System must meet the US Army Corp.’s Unified Facilities Guide Specifications, UFGS 25 10 10, “Utilities Monitoring and Control System” and UFGS 23 09 23, “Direct Digital Control for HVAC and Other Local Building Controls”.

M. The masking volume shall be adjustable via digital means for ½ dB steps for a range of 36-84 dBA as measured 1m from the center of the speaker.

N. Sound masking system must be able to provide music muting capabilities to allow paging to smoothly override the masking.

O. Spatial uniformity of sound must be no more than ±½ dBA.

P. Sound masking, paging and music must have individual identifiers located in an integrated LCD screen.

Q. Plenum mounted network locations must have a lighted LED for visual inspection.

R. System must be a multi-drop network system. Point to point systems are unacceptable.

S. System must be capable of being tuned through a network and a hand-held remote.

T. System must be capable of performing diagnostic functions.

U. System must be an open platform system. Proprietary software systems are

UNACCEPTABLE.

V. System must be capable of using off the shelf browser software for full manipulation.

W. System must be capable of being used as a stand-alone system or a system tied into an intranet IT spine or manipulated through the internet.

X. System MUST be an in-direct field system. Direct field only systems are unacceptable.

1.7 DESCRIPTION OF SYSTEM

A. All masking/paging units must be UL Listed for use in a ceiling plenum.

B. The system must be manufactured in the USA.

C. All equipment and associated hardware shall be fabricated and installed in accordance with the manufacturer's specified recommendations.

D. All wiring for power shall be minimum 16 gauge.

E. All Wiring for Data shall be CAT 5, 4 pair with RJ45 connectors.

F. All Wiring for Audio shall be CAT 5, 4 pair with RJ45 connectors.

G. Location of grounding points shall be determined carefully to insure minimizing of system hum and elimination of ground loops. In addition, all connections of shields and conductors to equipment shall be in

Advance Design Consultants, Inc. 27 51 19 - 4 04/06/2016 accordance with manufacturer's instructions and best professional practices.

H. In open areas and larger enclosed spaces, the overall sound level produced should have spacial uniformity of no more than ±½ dB between any two sound generating units.

I. The sound generating units must have an adjustable sound spectrum shaping control in order to meet the varying spectral requirements of drywall ceilings; various types of ceiling tile, air return grills and openings around lighting fixtures, etc.

1. The spectrum shaping ability shall be variable within the accepted background sound masking range (acoustical preferred curve).

2. Units will be able to be shaped with a 1/3 band octave equalizer.

3. Units will be able to shaped with a parametric equalizer

4. Equalizers will cover the full Spectrum and be able to manipulate entire spectrum from 20Hz to 20KHz

5. Systems that only cover PARTIAL ranges of spectrum (I.E. 1/3 of the 1/3 Octave Band) are UNACCEPTABLE

6. System must be capable at a minimum of delivering sound masking volume increments in

7. ½ dB steps. All system that can not deliver attenuation controls of at least ½ dB steps are unacceptable.

8. Units installed over drywall ceilings should be wired for spectrum control adjustment and remote sound level.

a. The system shall be capable of producing the sound spectrum and levels as specified in Section 3.3 of these specifications.

9. Spatial Uniformity (Directional Effect :) People in masked space under normal operating conditions cannot determine source of masking sound.

10. Temporal Uniformity: One minute time-averaged sound pressure level of any octave band of masking sound from 250 to 8000 Hz remains constant in any space to within a standard deviation of 2 dB when measured over a 30-minute period.

11. Sound Quality: No audible hum or noise, other than masking noise, from this system in masked spaces should be detected.

1.8 PERFORMANCE

A. The system shall be capable of producing masking frequencies

(20Hz – 20KHz) in the preferred spectrum range.

1. Each unit shall allow smooth and seamless adjustability of the

Advance Design Consultants, Inc. 27 51 19 - 5 04/06/2016 sound spectrum within the preferred curve, to allow for a variety of ceiling conditions.

B. Speaker housings/enclosures must be damped to avoid undesirable resonance.

C. System shall be designed so that individual speaker or component failure will have no impact on the balance of the system.

D. Security: Central control must only be able to be accessed via an authorized computer access point with the use of a password.

E. Design of system must be powered by low voltage.

1. Use adequately rated power supply’s.

a. a. Primary: 120-110 Volt AC 60 Hz

b. Secondary: 48 Volt DC

F. Power usage:

G. Power typical consumption: 60 Watts per 18,000 square feet for masking only.

H. Power typical consumption: 180 Watts per 18,000 square feet for masking and paging.

1.9 CODES AND PERMITS

A. Install all work in full accordance with the requirements of all local and governmental departments having jurisdiction over these matters, as well as with any requirements of the NFPA, MEA, BSA, UL, and other applicable Codes.

B. Secure and pay for necessary approvals, permits, inspections, carting, legal dumping, etc., and deliver the official records of the granting of permits to the Owner without additional cost.

C. Provide signs as required by the municipal authorities.

1.10 QUALIFICATIONS

A. Source Limitations: Obtain sound masking equipment components from a single source that assumes responsibility for compatibility of items used.

1. Components, speakers and power transformers must be UL listed for their appropriate use or listed as an equal to UL through another competent agency.

2. Green: Sound masking equipment must be comprised of at least 50% recycled content.

3. Privacy: Perform a speech and privacy evaluation to provide an articulation index (AI) as per ASTM E1130-02. A report of the AI must be provided with each exclusive project.

4. Manufacture Qualifications: Manufacturer must manufacture sound masking equipment and have a minimum of 10 years of sound masking experience. Sound masking product provided must be in

Advance Design Consultants, Inc. 27 51 19 - 6 04/06/2016 existence for a minimum of six years with proven performance criteria for providing speech privacy.

5. Warranty: A 10 year full warranty from the manufacturer must be provided for all sound masking equipment.

6. System is capable of using both in-plenum and direct field speakers by same manufacturer.

1.11 SUBMITTALS

A. Product Data: For each component including nationally recognized testing laboratory listing data.

B. Submit manufacturer's data or shop drawings of the following apparatus, giving full information as to dimensions, materials, and all information pertinent to adequacy of submitted equipment:

1. Masking Sound Speakers

2. Additional necessary masking equipment needed

3. Wire

4. Power supply

5. Paging/Music Equipment

6. Paging Only Speakers

7. Programmable Timers

C. Shop Drawings: Prepare and submit detailed dimensioned shop drawings for conduit runs (if required) and other distribution services including elevations showing minimum clearances and installed features and devices for system components. Show types and locations of masking speakers and their wiring connections. Channel assignments, and axis orientations. Show ducts, beams. And other significant sound reflecting and absorbing elements in ceiling space and show locations of partitions below ceiling. Include a diagram showing interconnection of major system components for each zone and channel and indicating grounding connections.

D. Each shop drawing shall contain job title and reference(s) to the applicable drawing(s) and/or specification article(s).

E. Product Certificates: Signed by manufacturers of sound masking equipment and components certifying that products furnished comply with requirements.

F. Qualification Data: For firms and persons specified in “Quality Assurance” Article.

G. Record of Final Field Tests and Measurements: Include final adjustment of system.

H. Maintenance Data: For sound masking equipment and components (if needed) to include in maintenance manuals specified in Division 1.

Advance Design Consultants, Inc. 27 51 19 - 7 04/06/2016

Include data for each type of product, including all features and operating sequences. Both automatic and manual.

1.12 COORDINATION

A. Coordinate quantity and arrangement of speaker assemblies with ceiling space configuration and with components occupying ceiling space, including structural members, Pipes air distribution components, raceways, cable trays, recessed lighting fixtures and other items.

1.13 OPERATING AND MAINTENANCE INSTRUCTIONS

A. Furnish a minimum of four complete sets of operating instructions and service maintenance manuals for the equipment employed in the systems.

This shall include wiring diagrams. The information in the manuals and on the drawings shall be sufficiently detailed to allow a technician of normal competence to understand, install, operate, maintain, calibrate and repair the equipment.

B. The Owner's designated operating personnel shall be provided instruction.

This shall include instruction in the operation, care and maintenance of the installation. Instruction shall be scheduled at the mutual convenience of the Owner and Subcontractor, after demonstrations and acceptance testing.

C. Diagnostics

1. System must be capable of performing a complete diagnostics of its entire functions including diagnostics of the network, hubs, nodes, routers, dsp’s, memory, circuitry, amplifiers and power.

D. Reporting Features

1. System must be capable of reporting entire settings for each zone for masking, paging and music indicating at a minimum the volume, contour, 1/3rd band octave equalization, parametric equalization, diagnostic, and grouping.

1.14 GUARANTEES AND CERTIFICATION

A. System shall be warranted to be free from defects in materials, workmanship, and performance for a 10-year from date of installation.

PART 2 - PRODUCTS

2.1 MANUFACTURERS

A. Shall be located in United State of America and shall provide a list of 10 Health Care Facilities completed with proposed system.

2.2 EQUIPMENT

A. The enclosure for the sound masking speakers shall consist of aluminum or electroplated steel, cylindrical housing.

B. Speakers: 5 ¼ inch units mounted on metal baffles and arranged for optimum, multi-directional, angular sound distribution. Arrange units for

Advance Design Consultants, Inc. 27 51 19 - 8 04/06/2016 suspension from the building structure above the ceiling.

C. The system must be capable of being independently zoned on both a global and local level for sound masking, paging and music. All zoning must be controlled from a network appliance.

D. CONTROL UNIT

1. System control unit must be LON or BACNET capable

2. System control unit must have digital input/output relays

3. System control unit must have TCP IP and serial port

4. Control unit must be able to control entire building without any additional controls

5. System control unit must be able to be browsed using off the shelf software

6. System control unit must be capable of providing email reports

7. System control unit must be capable of programming alarms, alarm triggers

8. System control unit must be capable of creating data logs.

E. LOUDSPEAKER

1. Size: 5 ¼ inch wide dispersion

2. Power Rating: 10 Watts Root Mean Squared (RMS)

3. Frequency Response: 50-12,000 Hz

4. Pressure Sensitivity: SPL - at 1 Watt/m - 90 dB

5. Impedance: 32 Ohms

6. Magnet Weight: 10 oz. (283.5 grams)

F. NOISE GENERATOR: Octave bands from 20Hz to 20KHz

1. Voltage: 48 Volts DC, 60 Hz

2. Contour Adjustments

3. Spectrum adjustment shall meet acoustical preferred curve

G. OUTPUT ADJUSTMENTS

1. 1/3 band EQ for entire spectrum (25Hz – 20KHz). Meets ANSI specification for bands

2. Parametric EQ for entire spectrum (20Hz – 20KHz)

3. Central volume control, contour control and EQ control for zones for sound masking.

4. Central volume control, and EQ control for zones and units for paging and music.

H. WIRE:

1. The power wiring shall be minimum 16 gauge, stranded, non-shielded, Advance Design Consultants, Inc. 27 51 19 - 9 04/06/2016

UL Listed, Plenum Rated

2. The data wiring shall be CAT 5, 4 pair with an RJ45 jack.

3. The audio wiring shall be CAT 5, 4 pair with an RJ45 jack.

I. Power Supply:

1. Output:

a. DC VOLTAGE: 48v

b. RATED CURRENT: 3.2A

c. CURRENT RANGE: 0~3.2A

d. RATED POWER: 153.6 W

e. OUTPUT VOLTAGE ADJ. RANGE: 45.6~52.8V

f. LINE REGULATION: ±0.5%

g. LOAD REGULATION: ±0.5%

h. SETUP, RISE TIME: 600ms, 30ms at full load

i. HOLD UP TIME (Typ.): 20ms at full load

2. Input:

a. Voltage Range: 110~120VAC 120~370VDC (Derating may be needed under low input voltages. Please check derating curve)

b. FREQUENCY RANGE: 47~63Hz

c. POWER FACTOR (Typ.): PF>0.93/230VAC PF>0.98/115VAC at full load

d. AC CURRENT (Typ.): 2.5A/115VAC 1.2A/230VAC

e. INRUSH CURRENT (Typ.): Cold Start 40A/230VAC

3. Safety: & EMC

a. SAFETY STANDARDS: UL60950-1, TUV EN60950-1 and S-Mark

J60950 Approved.

b. HARMONIC CURRENT: Compliance to EN61000-3-2,-3

c. EMS IMMUNITY: Compliance to EN61000-4-2,3,4,5,6,8,11;

ENV50204, EN55024, light industry level, criteria A

4. Environment:

a. WORKING HUMIDITY: 20 ~ 90% RH non-condensing

b. WORKING TEMP: -10 ~ +60 (Refer to output load derating curve)

c. STORAGE TEMP., HUMIDITY: -20 ~ +85 , 10 ~ 95% RH

d. TEMP. COEFFICIENT: 0.05%/ (0 ~ 50°C)

e. VIBRATION: 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes

5. Others:

a. MTBF: 191.2K hrs min. MIL-HDBK-217F (25°C)

Advance Design Consultants, Inc. 27 51 19 - 10 04/06/2016

b. DIMENSION: 7 27/32” x 3 29/32” x 1 15/16”

6. Protection:

a. OVERLOAD: 105 ~ 150% rated output power

b. Protection type : Constant current limiting, recovers automatically after fault condition is removed

c. OVER VOLTAGE: 52.8 ~ 64.8V

d. OVER TEMPERATURE: 95°C±5°C (TSW1: Detect on Heat sink of Power Transistor)

e. Protection type : Shut down o/p voltage, recovers automatically after temperature goes down

7. FUNCTION:

a. REMOTE CONTROL(OPTION): CN1:4 ~ 10VDC POWER ON,

1) <0 ~ 0.8VDC

b. POWER OFF J. Remote Central Volume and Contour Control:

1. Generation and integration of multiple random sound masking sources.

Channel outputs with three levels of global and independent control.

a. Contour control – At the source using infra-red technology for each independent channel, quad-pod and global control or via a centralized control.

b. Parametric equalization control for one to thousands of speakers.

c. 1/3rd Band Octave controls – (Same as Parametric controls for groups)

d. Volume control for entire spaces to channels to individual speakers.

2. Integration of separate paging and music channels

a. Each channel can be digitally controlled for zone management and changed on the fly without any change in wiring. No need to go back into the ceiling to change settings.

K. Programmable Audio-Level Control Unit:

1. Standard applications include scheduling, data logging, alarm detection

& dispatch, meter reading, analog functions, and type translation. The scheduling application permits events and exceptions to be initiated based on time and date schedules configured by the user. An astronomical position calculator permits scheduling to be done based on the calculated position of the sun. The data logging application collects network activity for use by trending, reporting, and analysis applications. New DIME support enables data log upload to a Web services application to occur through a firewall. The alarming application provides a means to identify, annunciate, and log alarm

Advance Design Consultants, Inc. 27 51 19 - 11 04/06/2016 conditions. The meter reading application supervises impulse meters and provides suitable conversion values for energy, gas, and water metering. Automatic Sound Power Level Changes: Two system channel changes, four times per day, and capable of different time settings for each day of the week:

a. Programmable attenuation range: -24 to +24 dB (48 dB)

b. Slide control attenuation range: -24 to +24 dB

c. Minutes per dB change: User programmable

d. Acclimation attenuation range: -24 to +24 dB

e. Acclimate days per dB change: 1 to 5 days

f. Programmable events: 24 events per day for each zone

2. Program Memory: Nonvolatile for one year, minimum, without power.

When re-energized after a power outage, control starts at zero level and automatically advances system sound level at same rate used for programmed level changes.

L. Paging/Music Equipment - Music Page Interface:

1. The Music Page Interface shall perform to the following requirements:

a. The music page interface should replace all bulky head end equipment. There should be no need for additional cable home-runs, amplifiers, separate equalizers, special switching equipment or matching vendors for compatible product interfaces.

b. The music page interface must be able to make zone additions, modifications, deletions and other changes to the paging and music/EBS system without rewiring.

c. The music page interface must be able to provide a minimum ability to program up to 100 zones for paging using DTMF tones through standard POTS telephone line. MPI must be able to be programmed for all call and emergency broadcast paging.

d. Each zone and group must have a dedicated one band octave equalizer that is able to adjust either individual zones or groups.

e. The music page interface must be able to from one point manage up to 1.5 million square feet of space through a single interface.

f. Volume and equalizer settings for paging and music must be administered in no more than ½ dB steps

g. The music page interface must automatically compensate and readjust for frequency line loss, broadcast and correct throughout the entire system at each node.

h. Must provide crystal clear page.

Advance Design Consultants, Inc. 27 51 19 - 12 04/06/2016

2. The paging interface shall perform to the following requirements:

a. TYPE 99-channel Paging, Music Interface

b. Once Octave EQ per channel capable with Sound Manager

c. INPUT VOLTAGE 7.5 Volts DC

d. INPUT CURRENT 333 Milliamps DC

e. ON/OFF SLIDE SWITCH

f. FREQUENCY RESPONSE 50 – 20,000 Hz (+ / - 3 dB)

3. INPUTS

a. Telephone page input…..POTS line telephone input. RJ12

Connector

b. Data Input: Screw Terminals

c. Music input….

1) Left channel, 10k ohm input impedance, single ended RCA jack (phono connector)

2) Right channel, 10k ohm input impedance, single ended RCA jack (phono connector)

3) Left and Right channels are combined to form one music input.

d. Aux input….

1) All Call Page, 10k ohm input impedance, single ended

RCA jack (special order)

4. OUTPUT

a. Cat5e data cable, RJ45 Connector. Connects to node

b. Three ground (Common) screw terminal block. Connects to (-) of first node

5. INDICATORS

a. 1 Power LED

b. 1 Telephone Answer/Hookup LED

6. TOTAL HARMONIC DISTORTION of Node (OP)

a. OP Output - 0.5% or less at 1kHz, rated output

b. OP Output - 0.1% of less at 1kHz, 5 W output

7. OTHER FEATURES Momentary push button sequencer to sequentially initialize attached nodes

8. DIMENSIONS 6” x 8 3/8” x 1 7/8”

9. ATTACHMENT POINTS 2 Screw tabs located on left and right of MPI

10. USAGE

a. Lift Telephone Receiver.

Advance Design Consultants, Inc. 27 51 19 - 13 04/06/2016

b. Dial Access Code.

c. Wait for short dial tone.

d. Dial two digit paging zone number and the # key. (00# for All Call).

e. Wait for short beep.

f. Issue Page.

g. Hang Up.

11. Node Paging/Music/EBS specification

a. OUTPUT REGULATION Less than 2.0 dB, no load to full load

b. SIGNAL TO NOISE RATIO Mic: 60 dB

c. (Band pass 20 – 20,000 Hz) Telephone Page: 75 dB

d. (Tone controls: set at center) Program: 75 dB, Aux: 75dB

e. One Octave EQ per Channel. ±5dB in ½ dB steps

f. CONTROLS

g. Volume (34 – 80dB) in 1/2dB steps via Central Control and/or IR

Remote

12. PAGING VOLUME ADJUSTMENTS:

a. Four channels/OP

b. Maximum output: 5.3 Volt RMS at speaker terminal

c. Attenuation range: 48 dB, in 1 dB steps, plus a mute setting.

13. PAGING ZONES

a. Individual channel, groups or global paging zones.

14. E.B./MUSIC VOLUME ADJUSTMENTS

a. Four channels/Node (OP)

b. Maximum output: 5.3 Volt RMS at speaker terminal

c. Attenuation range: 48 dB, in 1/2 dB steps, plus a mute setting

15. EMERGENCY BROADCAST/MUSIC ZONES

a. Individual channel, groups or global zones

16. PAGING/E.B./MUSIC OCTAVE EQUALIZER

a. One page/music equalizer for all channels

b. 10 bands, 31.5 Hz to 16 kHz, each user adjustable by ±5 dB in 1 dB steps

17. POWER SUPPLY

a. Input from building power: 100-240 VAC, 50-60 Hz, 1.0A

b. Output to MPI device: 7.5 VDC, 4.0A, 30W max

c. Power Consumption: 2.5W

PART 3 - EXECUTION

Advance Design Consultants, Inc. 27 51 19 - 14 04/06/2016

3.1 MOUNTING OF MASKING SOUND LOUDSPEAKERS

A. Mountings and Loudspeakers shall be concealed above the acoustical ceiling except in cases where direct radiating speakers in the ceiling may be necessary in some closed areas to prevent excessive sound in adjacent spaces. The ceiling plenum loudspeakers shall be suspended from the slab above by chain. Where possible, the bottom, of each speaker shall be located a minimum of 6" to 8” (150 to 200mm) above the acoustical ceiling tile.

However, it is most important that all units hang at a uniform height throughout to insure a uniformity of sound when the system is turned on. Direct radiating speakers are specifically required in rooms 628, 1029, 1030, and 1031, and at other locations as necessary to avoid excessive bleed of plenum sound.

Plenum speakers shall be kept as far away as practical from the closed conference rooms.

B. Wiring Method: Install wiring in accordance with all local electrical codes. Conceal cable in accessible ceilings, walls and floors where possible.

C. Pulling Cable: Do not exceed manufacturers’ recommended pulling tensions.

Do not install bruised, kinked, scored, deformed, or abraded cable. Do not splice cable between normal termination points. Remove and discard cable where damaged during installation and replace it with new cable.

D. Exposed Cable: Install parallel to building lines, follow surface contours, and support as recommended by manufacturer.

E. Grounding: As recommended by manufacturers, unless more stringent requirements are indicated. Ground equipment and conductors to eliminate shock hazard and to minimize ground loops. Common mode returns, noise pickup, cross talk and other impairments. Install 5-Ohm ground at main equipment location. Measure, record and report ground resistance.

F. Impedance Matching: For systems components including connecting cable, provide end-to-end level and impedance matched signal paths. Use matching networks and balancing devices at connections where necessary to avoid mismatches.

G. Splices, taps and terminations: Make splices, taps and terminations on numbered terminal strips in junction, pull and outlet boxes; and equipment closures.

H. The speaker locations shown on the drawings are schematic only and may require field modification to avoid major ductwork, structures and other plenum barriers. Additional speakers may be required to provide uniform sound distribution because of these plenum obstructions.

I. All local hanging codes must be reviewed and observed by the installer/contractor.

J. Identification:

1. Identify system components, wiring, cabling, and terminals according

Advance Design Consultants, Inc. 27 51 19 - 15 04/06/2016 to Division 16 Section “Electrical Identification” Use color coded conductors and apply wire and cable marking tape to designate wires and cables so media are identified in coordination with system wiring diagrams.

2. Identify system components, wiring, cabling, and terminals according to Division 16 Section “Basic Electrical Materials and Methods”. Use color coded conductors and apply wire and cable marking tape to designate wires and cables so media are identified in coordination with system wiring diagrams.

K. All equipment and associated hardware shall be fabricated and installed in accordance with the manufacturer's specified recommendations.

3.2 PRELIMINARY TESTS AND ADJUSTMENTS

1. At the completion of installation of speakers, the Subcontractor shall perform initial tests and adjustment. It is suggested that, with the speakers installed in accordance with specified spacing and orientation, measurements of the A-weighted sound level be made in representative open and closed areas to verify that the required sound level differentials between such spaces can be achieved, and if not that adjustments in loudspeaker locations or types be made before proceeding to final adjustments.

2. All testing and adjusting of the system shall be accomplished in the absence of the eventual occupants whenever possible. These precautions are essential to insure that the attention of the occupants will not be unnecessarily drawn to the noise or to its source.

3. Tests and adjustments shall be performed as described below.

a. Hum and Noise Level

b. Loudspeaker Operation

c. Freedom from Buzzes, Rattles and Objectional Distortion

d. Gain Control Settings

e. A written report representing the results of the above tests, including numerical values where applicable, shall be submitted for review

3.3 FINAL TESTS AND ADJUSTMENTS

A. The manufacturers’ agent with the support and cooperation of any

Subcontractor installer shall perform the acceptance testing of the completed installation. These tests shall be performed to demonstrate that the equipment is fully furnished and installed in compliance with the terms of the Specifications in all Contract Documents. Except as otherwise specified, the Manufacturer or Subcontractor shall provide all instruments, equipment, labor and materials necessary to complete these tests.

Advance Design Consultants, Inc. 27 51 19 - 16 04/06/2016

B. Manufacturers Field Service: Engage a factory authorized service representative to inspect field assembled components and equipment installation and connections. Report results in writing. Include the following.

1. Operational Test: Start system to confirm proper operation. Remove malfunctioning units, replace with new units and retest. Make initial sound spectrum and level adjustments for each zone. Test and adjust controls and safeties. Replace damaged and malfunctioning controls and equipment.

2. Test and adjust controls and safeties. Replace damaged and malfunctioning controls and equipment.

3. Inspection: Verify that units and controls are properly labeled and interconnecting wires and terminals are identified.

4. Sound Masking Level and Spectrum Adjustments: Measure and readjust as necessary until level and spectrum requirements stated below are met.

C. The Subcontractor shall project the completion date of tests and adjustments so that he can give a minimum of one week's notice to the active Project Manager.

D. Measurements of system performance shall be made using a calibrated ANSI S1.43 precision sound level meter with one-third octave band and octave-band filters. The measurements shall be made in each closed office and at not less than ten test positions in open areas of each floor at 4' height above the floor level. All interior finishes and furnishings shall be in place. Tests shall be for each floor at times not occupied by personnel. Record test observations, readings and corrective actions.

E. Final Acceptance Testing:

1. Initial measurements and adjustments may be made with the sound level of the system temporarily elevated to avoid interference from HVAC noise if desired. If so, specifications shall be similarly adjusted and shall apply to the adjusted final measurements with the elevated measurements. If such measurements for compliance with specifications are made at an elevated level, an additional set of measurements shall be made and recorded after levels are lowered.

2. The overall A-weighted sound level shall meet the following requirements:

Area Individual Measurements

Average of all Measurements

Open Areas 45 to 49 dBA 47 dBA +/- 1 dB

Closed Offices 40 to 45 dBA 42 dBA +/- 1 dB

Conference Rooms not more than 36 dBA not more than 34 dBA

Advance Design Consultants, Inc. 27 51 19 - 17 04/06/2016

3. The average of the third-octave spectra shall be as follows in the tolerances specified:

Frequency Open areas Closed offices Tolerance (see 4 below.)

160 42.5 37.5 +5,-4

200 42.5 37.5 +4,-3

250 42.5 37.5 +3,-2

315 42 37 +3,-2

400 41.5 36.5 +/-2

500 40.5 35.5 +/-2

630 39.5 34.5 +/-2

800 38.5 33.5 +/-2

1000 37.5 32.5 +/-2

1250 36 31 +/-2

1600 34.5 29.5 +/-2

2000 32.5 27.5 +/-2

2500 30.5 25.5 +3,-2

3150 28.5 23.5 +3,-2

4000 26.5 21.5 +4,-2

5000 24 19 +4,-2

6300 21 16 +5,-2

8000 16.5 11.55 +5,-2

4. For the average spectrum, the level in any 1/3 octave band above

160 Hz shall not in any case be more than 3 dB greater than the level in the adjacent lower 1/3 octave band.

5. Walk-Through Test: People in masked spaces cannot discern speaker

Advance Design Consultants, Inc. 27 51 19 - 18 04/06/2016 locations.

6. Temporal Stability Test: Check for uniformity of time by measuring sound level in each of 6 octave bands from 250 to 8000 Hz at one-minute intervals over a 30- minute test period.

Deviations must not exceed a standard deviation of 2 dB.

F. Retest: Correct deficiencies identified by tests and observations and retest until meeting specified requirements.

G. Recording Control Settings and System Adjustments: Record final control settings and programming and final tap setting of speaker matching transformers. Record final sound level measurements and observations.

3.4 ADJUSTMENT

A. Occupancy Adjustments: When requested within 12 months of date of substantial completion manufacturer is to provide on site assistance in adjusting system to suit actual occupied conditions. Provide one visit to site outside normal occupancy hours for this purpose without additional cost to the owner.

3.5 DEMONSTRATION

A. Engage a factory authorized service representative to train Owner’s maintenance personnel to adjust, operate and maintain services as specified below:

1. Train owner’s maintenance personnel on procedures and schedules for starting up and shutting down, troubleshooting, servicing, and maintaining equipment and schedules as indicated on Section 27 08

00 COMMISSIONING OF COMMUNICATION SYSTEMS.

2. Review data in maintenance manual. Refer to Section 27 05 11

CLOSEOUT SUBMITTALS.

a. Review data in maintenance manual. Refer to Section 27

05 11 CLOSEOUT SUBMITTALS.

b. Schedule training with owner through Architect with at least seven days advance notice.

END OF SECTION 27 51 19

27 51 19 Networked Sound-Masking Equipment-VA-ADC-NR.pdf
PART 1 - GENERAL
1.2 SUMMARY
1.3 DEFINITIONS AND REFERENCES
1.4 AMERICAN NATIONAL STANDARDS INSTITUTE (ANSI):
1.5 AMERICAN SOCIETY FOR TESTING AND MATERIALS (ASTM):
1.6 SYSTEM PERFORMANCE
1.7 DESCRIPTION OF SYSTEM
1.8 PERFORMANCE
1.9 CODES AND PERMITS
1.10 QUALIFICATIONS
1.11 SUBMITTALS
1.12 COORDINATION
1.13 OPERATING AND MAINTENANCE INSTRUCTIONS
C. Diagnostics
1.14 GUARANTEES AND CERTIFICATION
PART 2 - PRODUCTS
2.2 EQUIPMENT
PART 3 - EXECUTION
3.2 PRELIMINARY TESTS AND ADJUSTMENTS
3.3 FINAL TESTS AND ADJUSTMENTS
3.4 ADJUSTMENT
3.5 DEMONSTRATION