A3. Panels_Annunciators_Redacted.pdf
PDF 78 KB Posted
- Attached to
- Fire Protection & Life Safety Inspection, Testing, and Certification (ITC) for Spokane WA VAMC
- Solicitation number
- 36C26024Q0901
About this file
This document is a fire alarm system inspection report for the VA MED CENTRE CAMPUS in Spokane, Washington. It provides details on the monthly fire alarm system inspection conducted on July 8, 2023, including the types of equipment tested, the test results, and the system performance. All tests were reported as satisfactory. The report is signed by the fire alarm firm representative.
The related federal contract opportunity is a solicitation for Fire Protection & Life Safety Inspection, Testing, and Certification (ITC) services for the Mann-Grandstaff (Spokane) VAMC. It is a base plus four option year contract, and is a 100% Small Business Set-aside. Interested vendors are required to submit quotes in four parts as specified in Section E.2., and the award will be based on the criteria outlined in Section E.6. The solicitation number is 36C26024Q0901, and the contract is planned to begin in FY25, subject to availability of funds.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
FIRE ALARM SYSTEM
Report of Inspection
Date 7-8-23 of facility VA MED CENTRE CAMPUS
Occupied as _HOSPITAL
Address 4815 N ASSEMBLY_____________________ City _____SPOKANE_________
County __SPOKANE_____________ Zip __99205________ Telephone ___________________
Building designation (if more than one building) _____________________________
_________________ Title __service tech_______________
Date of inspection 7-9-22_______
1. Type of test: monthly [ ] quarterly [ ] semi-annual [ ] annual [X ]
2. Type of system: non-coded [X ] common coded [ ] selective coded [ ] dual coded [ ]
3. Local Fire Department ______
4. Fire Department official contacted ________
5. Comments, explanation of unsatisfactory results, action taken, repairs made, etc.
______ALL TEST GOOD
Type of Equipment
# of Units
Tested
Test Date
Satisfactory Check
Yes No N/A
Type and Manufacturer
6. Control panel 17 7-8-23 X EST 3
7. Manual station 187 7-8-23 X SIGA-278
8. Heat detectors 44 7-8-23 X SIGA HRS HFC
9. Smoke detectors 474 7-8-23 X SIGA -PS
10. Audible alarms 176 7-8-23 X EST-GIRF/G4RF
11. Visual alarms 188 7-8-23 X EST
12. Duct detectors 119 7-8-23 X EST
13. Auto. Security door releases
14. Trouble indicators 21 7-8-23 X FACP
15. Charger 47 7-8-23 X FACP/BPS
16. Generator
17. Ventilation control relays
18. Fire door holders
19. Central station interconnection 1 7-8-23 X TELCO
20. Exterior sprinkler electric alarm bell
21. Sprinkler water flow switch TESTED BY
22. Sprinkler gate valve tamper switch
OTHERS
23. Annunciators 4 7-8-23 X EST3
Tested battery % or
System Demand Design total
Load Test
Satisfactory
Battery description, size, and how many
Amp Draw
Standby or test %
Batt. #1
Amp Draw
Alarm or test %
Batt. #2
Load Test
Type.
Amp Hour
Available
Yes
No
24. BATT 18VOLT .241 .248 NO AC 18 HOUR X
25. Automatic time delay of general alarm _____0_____ minutes. None installed [X ]
26. Test of alarm system on emergency power satisfactory? Yes [x ] No [ ]
27. This is to certify that this fire alarm system has been properly inspected and functions as designed covering the times listed in this report and is consistent with local and NFPA Fire Alarm Maintenance Standards.
A. Signature of owner or representative ________________________________________________________
B. Signature of fire alarm firm representative
28. Smoke detector sensitivity testing provided:
A. Yes, service form attached and copy filed with owner. Comments:_________________________________
B. No, owner refused. Comments: ___________________________________________________________
C. NA (not applicable or not due). Comments: ___not due____________________________________ a:servfrms.doc rev. 12/21/2011
File details come from the government source that posted it. Updated .